02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system...

8
Revisions Notes TI 2009/003 1 proposed commercial development on plot no. L.R. 1/588 Argwings Kodhek road Hurlingham for PROJECT DRG. TITLE ARCHITECTS TECTURA INTERNATIONAL Planners, Architects and Interior designers Tectura Studio 2727 The Crescent - Parklands P.O. Box 54634-00200 Tel. 254(2) 3751443 -3751465 -3751680 -3751685 Fax. 254(2) 3745588 Nairobi Kenya. Project No. Drawn: Ckk Scale: 1:100 Date: June 2011 Checked: NM Drg. No. Proposed works Existing works Demolition works Existing sewer Proposed sewer Existing storm water drain Proposed storm water drain SAIMAR LTD. Architect's signature.............................................Reg No................... This drawing shall be read in conjunction with the Engineer's drawings. Any descripancies MUST be reported to the Architect. This drawing must be checked against existing site conditions and any descrepancy reported to the Architect . Figured dimensions only to be taken from this drawing. All samples must be approved by the Architect before any use. All dimensions are in millimeters unless otherwise indicated. All floors are to have a hydrolic fire hosereels connected to a 6000litre reserve water tank with automatic booster pumps and 2 9litre CO2 fire extinguishers. All floors ars to have manual electric break glass connected to fire alarm system. Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps -1. Basement No. Date Description 44.27 m 2 69.05 m 2 29.74 m 2 20.55 m 2 20.55 m 2 PARKING FIRE ESCAPE FIRE ESCAPE RAMP WATER PUMP ROOM PARKING STORAGE ROOM fire hose reel D7 D7 D10 D10 fire hose reel fire hose reel D11 D11 D10 D10 sump 300mm wide drain channel with grating sump size 600x600x 700mm deep sump size 1000x1000x 1350mm deep 300mm wide drain channel with grating 200mm wide drain channel with grating 300mm wide drain channel with grating STORE fire hose reel CONCRETE WATER STORAGE TANK ROOM 200mm wide perforated reinforced concrete baffer wall to SE details 200mm wide reinforced concrete wall to SE details 200mm wide reinforced concrete wall to SE details precast concrete louvres to architects approval precast concrete louvres to architects approval precast concrete louvres to architects approval precast concrete louvres to architects approval STORE D2 pv D2 pv pv pv pv pv pv pv switch panel LIFT LOBBY

Transcript of 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system...

Page 1: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 1

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

-1. Basement

No. Date Description

44.27 m2

69.05 m2

29.74 m2

20.55 m220.55 m2

PARKING

FIREESCAPE

FIREESCAPE

RAMP

WATER PUMPROOM

PARKING

STORAGEROOM

firehose reel

D7D7

D10

D10

firehose reel

firehose reel

D11

D11

D10

D10

sump

300mm wide drainchannel with grating

sump size600x600x 700mm deep

sump size1000x1000x 1350mm deep

300mm wide drainchannel with grating

200m

m w

ide

drai

nch

anne

l with

gra

ting

300mm

wide drain channel w

ith grating

STORE

firehose reel

CONCRETE WATERSTORAGE TANK ROOM

200mm

wide perforated reinforced

concrete baffer wall to SE details 200mm wide reinforced

concrete wall to SE details

200m

m w

ide

rein

forc

edco

ncre

te w

all t

o SE

det

ails

precast concrete louvresto architects approval

precast concrete louvresto architects approval

precast concrete louvresto architects approval

precast concrete louvres

to architects approval

STORE

D2pv

D2pv

pv

pv

pv

pv

pv

pv

switch panel

LIFT LOBBY

Page 2: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 2

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

0. Ground Floor

No. Date Description

46.00 m2385.42 m2

34.60 m2

385.42 m2

13.59 m213.59 m2

2.94 m2

2.94 m2

12.11 m2

346.83 m2

gents ladies

FIREESCAPE

FIREESCAPE

LIFT LOBBY

LETTABLE OFFICERESTAURANT

LETTABLE OFFICESPACE

boundary wall

to detail

building line

boundary wall

to detail

boundary wall to detail

boundary wall to detail

boundary wall

to detail

boundary wall to detail

boundary wall to detail

pv

firehose reel

elect.duct

svp svp

mh

proposed sewerline below slab

proposed sewerline below slab

PARKING

PEDESTRIANACCESS

ARGWINGS KODHEK ROAD

TO BASEMENTPARKING

D1

D2 D2

D13 D13

D3 D3

D4D4

D4 D4

D5

D5

D5

D5

D6

D7

D6

D7

D8 D9

ic

ic

storm water channel

storm water channel

D4

D12SENTRY

W16

W17

W16

ic

GENERATORROOMPOLE M

OUNTED

TRANSFORMER

D10

300mm wide drain channel with grating

rwdp rwdp

W1

W8

W8

W8

W9

W8

W9

rwdp rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

ventilationduct

D2

rwdp

rwdp

IC

IC

W3

W2

W1

pv

pv pv

pv

pv

pv pv

pv

pv

pv

pv

pv

pv pv

pv

W1

W3

W2

W1

pv

W1

W3

W2

W1

pv

W1

W3

W2

W1

pv

pv

pv

pv

pv

pv

pv

pv

pv

pv

pv

pv

pv

pv pv

storm water channel

storm water channel

RAMP

RAMP

up

up

up

up

up

new staircase to detail

W16

LETTABLE OUTDOOR SEATINGSPACE

svp

svp

svp

svp

svp

svp

svp

svp

svp

cleanersstorekitchen

Page 3: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 3

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

1. First Floor

No. Date Description

401.36 m2 401.36 m2

50.15 m2

13.59 m213.59 m2

12.11 m2

2.94 m2

2.94 m2

CANOPY

FLAT ROOFOVER RAMP

gents ladies

FIREESCAPE

FIREESCAPE

LIFT LOBBY

LETTABLE OFFICESPACE

LETTABLE OFFICESPACE

elect.duct

svp svp

firehose reel

D2 D2

D13 D13

D3 D3

D4D4

D4 D4

D5

D5

D5

D5

D6 D6

D8 D9

rwdp rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

polycarbonatebarrel roof

ventilationduct

fulbora

fulbora

fulbora fulbora

fulbora

fulbora

fulbora

fulbora

W4

W6

W5

W4

pv

pv

pv

pv

W6

W6

pv

pv

W7

W4

pv

pv pv

pv pv

pv pv

pv pv

W8pv

W4

W6

W5

W4

pv

pv

pv

pv

W6

pv

pv

W8pv

W4

W6

W5

W4

pv

pv

pv

pv

W6

W6

pv

pv

W8pv

W9 W9

W6

W4

W6

W5

W4

pv

pv

pv

pv

W6

pv

W8pv

AIR HANDLINGUNIT

D2pv

svp

svp

svp

svp

svp

svp

svp

svp

kit cleanersstore

Page 4: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 4

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

2. Second Floor

No. Date Description

13.59 m213.59 m2

369.91 m2 369.91 m2

45.15 m2 45.15 m2

50.15 m2

12.11 m2

gents ladies

FIREESCAPE

FIREESCAPE

LIFT LOBBY

LETTABLE OFFICESPACE

LETTABLE OFFICESPACE

elect.duct

svp svp

firehose reel

D2 D2

D13 D13

D3 D3

D4D4

D4 D4

D5

D5

D5

D5

D6 D6

D8 D9

rwdp rwdp

rwdp rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

fulbora

fulbora

fulbora

fulbora

fulbora

fulbora

BALCONY BALCONY

rwdp

W9 W9

W4

W6

W5W4pv

pvpv

pv

W6

W6

pv

pv

W8pv

pv

pv

pv

pv

W10

W10

pv

pv

W10

W10

pv

pvpv

pv pv

pvpv

pv pv

W4

W6

W5

W4

pv

pv

pv

pv

W6

pv

pv

W8pv

W6

W4

W6

W5

W4

pv

pv

pv

pv

W6

pv

pv

W8pv

W6

D2pv

svp

svp

svp

svp

svp

svp

svp

svp

Page 5: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 5

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

3. Third Floor

No. Date Description

13.59 m213.59 m2 13.59 m213.59 m2

369.91 m2 369.91 m2

50.15 m2

12.11 m2

2.94 m2

2.94 m2

gents ladies

FIREESCAPE

FIREESCAPE

LIFT LOBBY

LETTABLE OFFICESPACE

LETTABLE OFFICESPACE

PV

PV

elect.duct

svp svp

firehose reel

D2 D2

D13 D13

D3 D3

D4D4

D4 D4

D5

D5

D5

D5

D6 D6

D8 D9

PV

PV

rwdp rwdp

rwdp rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

W9 W9

pv pv

W4

W5

W4

W8

W3

pv

pv

pv

pv

pv

W4

W5

W4

W8

W3

pv

pv

pv

pv

pv

W4

W11

W8

W3

pv

pv

pvpv

pv

W11

W5W4

pvpv

W11

pv

pv

W11

W3pv

pvpv

pv pv

pvpv

D2pv

svp

svp

svp

svp

svp

svp

svp

svp

kit cleanersstore

Page 6: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 6

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

4. 4th floor Extension

No. Date Description

13.59 m213.59 m2

50.15 m2

12.11 m2

445.67 m2445.67 m2

2.94 m2

2.94 m2

gents ladies

FIREESCAPE

FIREESCAPE

LIFT LOBBY

LETTABLE OFFICESPACE

LETTABLE OFFICESPACE

elect.duct

svp svp

firehose reel

D2 D2

D13 D13

D3 D3

D4D4

D4 D4

D5

D5

D5

D5

D6 D6

D8 D9

rwdprwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

D2rwdp

pvpv

pv pv

pvpv

pv pv

W8pv

pvW8

pvW8

pvW8

W13pv

W12

W12

W12W12

W12

W12

W12

W13

pv

pv

pvpv

pv

pv

pv

W12

W12

W12

W12

W13 W13

pv

pv

pv

pvW12

pv

W12

pv

pv

pv

pv

W9 W9

pv

svp svp

svp

svp

svp

svp

svp

svp

svp

svp

kit cleanersstore

Page 7: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 7

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

5. 5th Floor Extension

No. Date Description

13.59 m213.59 m2

50.15 m2

12.11 m2

445.67 m2445.67 m2

2.94 m2

2.94 m2

rwdp rwdp

LIFT LOBBY

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

W9 W9

W8pv

pvW8

pvW8

pvW8

W15

W15

W15

W15W15

W15

W15

W15

W15

W15

W15

W15

W15

W15

W15

W15

W15

pv pv

down down

elect.duct

D2 D2

D8 D9

pvpv

ADDITIONAL LETTABLEOFFICE SPACE (ROOF)

ADDITIONAL LETTABLEOFFICE SPACE (ROOF)

gents ladies

D13 D13

D3 D3

D4D4

D4 D4

D5

D5

D5

D5

pv pv

pvpv

svp svp

D2pv

D6D6

svp

svp

svp

svp

svp

svp

svp

svp

svp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdp

rwdpkitchen cleaners

store

150mm Ø m.s column spray painted toapproval bolted onto r.c column to s.edetails

150mm Ø m.s column spray painted toapproval bolted onto r.c column to s.edetails

Page 8: 02 0. Ground Floor Layout · Basement floor is to be served with automatic sprinkler system connected to a 6000 litre reserve water tank with automatic booster pumps 0. Ground Floor

Revisions

Notes

TI 2009/003 8

proposed commercial development on plotno. L.R. 1/588 Argwings Kodhek roadHurlinghamfor

PROJECT

DRG. TITLE

ARCHITECTS

TECTURA INTERNATIONALPlanners, Architects and Interior designersTectura Studio 2727 The Crescent - ParklandsP.O. Box 54634-00200Tel. 254(2) 3751443 -3751465 -3751680 -3751685Fax. 254(2) 3745588Nairobi Kenya.

Project No.

Drawn: Ckk

Scale: 1:100

Date: June 2011

Checked: NMDrg. No.

Proposed worksExisting works

Demolition worksExisting sewerProposed sewerExisting storm water drainProposed storm water drain

SAIMAR LTD.

Architect's signature.............................................Reg No...................

This drawing shall be read in conjunction withthe Engineer's drawings. Any descripanciesMUST be reported to the Architect.

This drawing must be checked against existingsite conditions and any descrepancy reportedto the Architect .

Figured dimensions only to be taken from thisdrawing.

All samples must be approved by the Architectbefore any use.

All dimensions are in millimeters unlessotherwise indicated.

All floors are to have a hydrolic fire hosereelsconnected to a 6000litre reserve water tankwith automatic booster pumpsand 2 9litre CO2 fire extinguishers.

All floors ars to have manual electric breakglass connected to fire alarm system.

Basement floor is to be served with automaticsprinkler system connected to a 6000 litrereserve water tank with automatic boosterpumps

IMAGE

No. Date Description

VIEW FROM MAIN ROAD