01. Sharing Session OMC

download 01. Sharing Session OMC

of 14

Transcript of 01. Sharing Session OMC

  • 8/7/2019 01. Sharing Session OMC

    1/14

    SHARING KNOWLEDGEOMCR ZTE

  • 8/7/2019 01. Sharing Session OMC

    2/14

    OMC Topology

  • 8/7/2019 01. Sharing Session OMC

    3/14

    MINOS Topology

  • 8/7/2019 01. Sharing Session OMC

    4/14

    SBCX Board

    SBCX Function :

    - Collect KPI Data and

    transfer to RNC Server

    - As OMCB, can AccessLMT from RNC

  • 8/7/2019 01. Sharing Session OMC

    5/14

    Severity

    Warning

    Minor

    Major

    Critical

  • 8/7/2019 01. Sharing Session OMC

    6/14

    Frequently Happened Alarm in Kalimantan

    Warning Type

    - Transmission Clock is Unlocked

    Solution : Clear manual from fault management

    Affect : -

    - RRU RTWP Alarm

    Solution : Change RRU (faulty hardware)

    Affect : Can service but receive signal getting worst

    - SNTP Alarm. Alarm that only affect time adjustment, it is

    no related to Traffic and Service

  • 8/7/2019 01. Sharing Session OMC

    7/14

    Frequently Happened Alarm in Kalimantan

    Minor Type

    - E1/T1 Link Loss ofFrame Alarm, E1/T1 Remote receiving

    fault, E1/T1 Link Loss of IMA Group, E1/T1 Cell delineation

    alarm, E1/T1 Loss of Signal

    Solution : Check E1 Link per hop

    Affect : E1 not active, path group bandwidth decrease

    1920 kbps / Link

  • 8/7/2019 01. Sharing Session OMC

    8/14

    Minor Type

    - SSCOP Link Broken, IMA Group not Operational

    Solution : Transmission Problem, Check Link

    Affect : Node-B wont start-up

    - Ir LOS Optical Alarm port 0/1/2 (Sector 1/2/3)

    Solution : ChangeFiber Optic cable, Change optic

    connector in BBUB or RRU

    Affect : 1 cell out of service

    Frequently Happened Alarm in Kalimantan

  • 8/7/2019 01. Sharing Session OMC

    9/14

    Minor Type

    - PA Power alarm

    Solution : Change RRU

    Affect : 1 Sector out of service, RRU only receive 5 Db

    Power

    - DSP run failed

    Solution : Change BPHX Board

    Affect : 1 Node-B out of service

    Frequently Happened Alarm in Kalimantan

  • 8/7/2019 01. Sharing Session OMC

    10/14

    Major Type

    - VSWR Alarm

    Solution : Reset RRU, Change Jumper RRU to Antenna,

    Change RRU

    Affect : 1 Cell out of service

    Frequently Happened Alarm in Kalimantan

  • 8/7/2019 01. Sharing Session OMC

    11/14

    Critical Alarm

    - Node-B Out of Service

    Solution : Check Link Transmission

    Affect : 1 Node-B out of service

    Frequently Happened Alarm in Kalimantan

  • 8/7/2019 01. Sharing Session OMC

    12/14

    MISC.

    MISC.

    File that must running in SBCX / Log Server :

    - SubdiskL.bat & logserver.exe

    File that must running in OMC Server :

    - CORBA & FTP Server

  • 8/7/2019 01. Sharing Session OMC

    13/14

    MISC.

    When we need to :

    Add Carrier : Code Resources Very High,

    Difficult to make CS-PS Call

    Add BPHX : CE Utilization Very High

    Add IuB : IuB Utilization High

  • 8/7/2019 01. Sharing Session OMC

    14/14