004 ZXSDR NodeB Data Configuration_PPT-42

42
ZXSDR NodeB Data Configuration ZTE University

Transcript of 004 ZXSDR NodeB Data Configuration_PPT-42

Page 1: 004 ZXSDR NodeB Data Configuration_PPT-42

ZXSDR NodeB Data Configuration

ZTE University

Page 2: 004 ZXSDR NodeB Data Configuration_PPT-42

Content

Overview

NodeB Configuration

Ground Resource Configuration

Transmission Resource Configuration

Wireless Resource Configuration

Page 3: 004 ZXSDR NodeB Data Configuration_PPT-42

Overview--LMT Data Configuration Mode

On-line configuration This mode is to configure the ZDB of the B8200 directly. The data configured

on the line take effect immediately. To configure on the line, modify the contents in the C:\ump file first, to set the IP address as the IP address of the debugging network interface on the CC board of the B8200. Then, run the LMT. The CC board is defaulted before delivery.

Off-line configuration This mode is to modify the configurations on the client. The configurations are

saved into the designated directory in the mode of the XML file. In the off-line configuration, the LMT is not connected to the B8200 and the operation does not affect the running of the B8200. The off-line configuration mode is used when there is no ump file under the root directory of the Disc C. One local configuration file is required for the off-line configuration.

Page 4: 004 ZXSDR NodeB Data Configuration_PPT-42

Node B Application Part

(NBAP)

Transport Layer

Radio Network Layer

Radio Network Control Plane

Transport Network

Control Plane

DC

H F

P

RA

CH

FP

Physical Layer

DS

CH

FP

Data Link

User Plane

SCTP

IP

FA

CH

FP

PC

H F

P

US

CH

FP

CP

CH

FP

Data Link

IP

UDP

Overview--Iub Interface Protocol Stack ( IPOE)

Page 5: 004 ZXSDR NodeB Data Configuration_PPT-42

Overview--LMT Data Configuration Flow

IP Over FE Mode Transmission Data Configuration Flow :

Prepare

Plan parameters for

RNC interconnection

NodeB Configuration

NodeB basic

attributes

Rack and

board configuration

Serial port

configuration

clock referen

ce source

Ground resource configuration

Environment monito

ring

Dry contact configuration

Topology

structure

setting

Transmission resource

configuration

Ethernet

parameter

IP param

eter

Globe port Parameter

Static route param

ete

Wireless resource configuration

RRU Common Paramet

er

Base Band

Resource Pool

RF Connec

tion

WCDMA Sector

Local Cell

End

SCTP stream parameter

SCTPparameter

OMCB parameter

IP Clock parameter

BFD param

eter

Page 6: 004 ZXSDR NodeB Data Configuration_PPT-42

Content

LMT Data Configuration

NodeB Configuration

Ground Resource Configuration

Transmission Resource Configuration

Wireless Resource Configuration

Page 7: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

NodeB Basic Attributes Clock Reference Source Configuring Rack and Board

Page 8: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Setting NodeB Basic Attributes :Basic Parameter and Other Relevant Parameters

Page 9: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Page 10: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Page 11: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Configuring Rack and Board : Create RRU rack

Page 12: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Configuring Rack and Board : Create board on BBU and RRU rack

Page 13: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Configuring Rack and Board : Create board on BBU and RRU rack

Page 14: 004 ZXSDR NodeB Data Configuration_PPT-42

NodeB Configuration

Configuring Clock Reference Source : Right-click and choose Configuration Management BS Configure Clock Reference Source. Configure Clock Reference Source dialog box pops up.

Page 15: 004 ZXSDR NodeB Data Configuration_PPT-42

Content

LMT Data Configuration

NodeB Configuration

Ground Resource Configuration

Transmission Resource Configuration

Wireless Resource Configuration

Page 16: 004 ZXSDR NodeB Data Configuration_PPT-42

Ground Resource Configuration

Environment Monitoring In-line Tower Amplifier Serial Port Topology structure AISG Device Dry Contact

Page 17: 004 ZXSDR NodeB Data Configuration_PPT-42

Ground Resource Configuration

Configuring Environment Monitoring: click Configuration Management→ Ground Resource Management→ Environment Monitoring to open the Environment Monitoring window:

Page 18: 004 ZXSDR NodeB Data Configuration_PPT-42

Ground Resource Configuration

Configuring Topology Structure: Click Configuration Management→ Ground Resource Management→ Topology to open the Topology window.

Page 19: 004 ZXSDR NodeB Data Configuration_PPT-42

Ground Resource Configuration

Configuring Topology Structure:

About upper-level and lower-level in the topology configuration: The board/rack near the baseband processing unit is the upper-level The board/rack away from the baseband processing unit is lower-level.

Page 20: 004 ZXSDR NodeB Data Configuration_PPT-42

Ground Resource Configuration

Configuring Dry Contact

Page 21: 004 ZXSDR NodeB Data Configuration_PPT-42

Content

LMT Data Configuration

NodeB Configuration

Ground Resource Configuration

Transmission Resource Configuration

Wireless Resource Configuration

Page 22: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

For the IP over FE transmission, the following nine items should be configured: Ethernet Parameter Global Port Parameter IP Parameter Static Route Parameter SCTP Parameter SCTP Stream Parameter IP Clock Parameter BFD Parameter OMC-B Parameter

Page 23: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring Ethernet Parameter--Click Physical Media Configuration→ Ethernet parameter .Right-click the blank part in this pane and choose Add to open the Ethernet parameter management dialog box:

Page 24: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring Global Port Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ Global port parameter to open the Global port parameter pane. Right-click the blank part in this pane and choose Add to open the Global Port Parameter dialog box:

Page 25: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring IP Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ IP parameter to open the IP parameter pane. Right-click the blank part in this pane and choose Add to open the IP Parameter Management dialog box:

Page 26: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring Static Route Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ Static Router Parameter. Right-click the blank part in the right pane and choose Add to open the Static route configuration dialog box.

Page 27: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring SCTP Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ SCTP Parameter to open the SCTP parameter pane. Right-click the blank part in this pane and choose Add to open the SCTP parameter management dialog box:

Page 28: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring SCTP Stream Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ SCTP Stream Parameter to open the SCTP stream parameter pane. Right-click the blank part in this pane and choose Add to open the SCTP stream parameter management dialog box.

Page 29: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring IP Clock Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ IP Clock Parameter to open the IP Clock parameter pane. Right-click the blank part in this pane and choose Add to open the IP Clock parameter dialog box.

Page 30: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring BFD Parameter--Click Transmission Resource Management→ IP Bearing Configuration→ BFD Parameter to open the BFD parameter pane. Right-click the blank part in this pane and choose Add to open the BFD parameter dialog box.

Page 31: 004 ZXSDR NodeB Data Configuration_PPT-42

Transmission Resource Configuration

Configuring OMC-B Parameter

Page 32: 004 ZXSDR NodeB Data Configuration_PPT-42

Content

LMT Data Configuration

NodeB Configuration

Ground Resource Configuration

Transmission Resource Configuration

Wireless Resource Configuration

Page 33: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

RF Connection RRU Common Parameter Base Band Resource Pool WCDMA Sector Local Cell

Page 34: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring RF Connection--Click Wireless Resource Management→ RF Connection to open the RF Connection pane. Right-click the blank part in this pane and choose Add →Rack to open the RF Connection dialog box.

Page 35: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring RRU Common Parameter --Click Wireless Resource Management→ RRU Common Parameter to open the RRU Common Parameter pane. Right-click the blank part in this pane and choose Add to open the RRU Common Parameter dialog box.

Page 36: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring Baseband resource pool--Click Wireless Resource Management→ Baseband Resource Pool and right-click the blank part in this pane and choose Add to open the baseband resource pool Management dialog box:

Page 37: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring Baseband resource--Click Baseband Resource Pool→ Baseband Resource to open the Baseband Resource pane. Right-click the blank part in this pane and choose Add to open the Baseband Resource dialog box:

Page 38: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring WCDMA Sector--Click Wireless Resource Management→ WCDMA Sector to open the WCDMA Sector pane. Right-click the blank part in this pane and choose Add to open the WCDMA Sector dialog box:

Page 39: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring Local cell--Click Wireless Resource Management→ WCDMA Sector to open the WCDMA Sector pane. Right-click the blank part in this pane and choose Add Local Cell to open the Local Cell Management dialog box:

Page 40: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring Local cell

Page 41: 004 ZXSDR NodeB Data Configuration_PPT-42

Wireless Resource Configuration

Configuring Local cell

Page 42: 004 ZXSDR NodeB Data Configuration_PPT-42