5 NodeB Troubleshooting

38
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved www.huawei.com Internal NodeB Troubleshooti ng V100R007

Transcript of 5 NodeB Troubleshooting

Page 1: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

www.huawei.com

Internal

NodeB Troubleshooting

V100R007

Page 2: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved

References

《 RAN Troubleshooting

Cases》 SUPPORT.HUAWEI.COM

Page 3: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

Upon completion of this course, you w

ill be able to:

Know how to find NodeB faults

Grasp NodeB troubleshooting met

hods

Know how to prevent NodeB faults.

Page 4: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

Chapter 1 General IntroductionChapter 1 General Introduction

Chapter 2 Typical CasesChapter 2 Typical Cases

Chapter 3 NodeB Fault PreventionChapter 3 NodeB Fault Prevention

Page 5: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

General Introduction

Alarm

Alarm console

Alarm box

OMC Shell

Traffic statistics

Drive test

Routine inspection

Customer complain

The ways to find faults The ways to find faults

Page 6: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

Locating faulty equipments

If RNC has fault, usually it will affect some Sites or all of Sites

If NodeB has fault, usually it just affect itself and the handover su

ccessful rate of adjacent cells

During implementation or expansion, we can “Interchange ” Node

B and judge the fault is because of RNC or NodeB

During maintenance, RNC faults don’t just affect one NodeB

General Introduction

Page 7: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

General Introduction

RAN fault

Cell

Traffic

Link

Interconnection

Clock

Antenna & Feeder

transmission

Operation and maintenance fault

OMC

Software Loading

RNO fault

Access

Call drop

Congestion

Handover

Common fault typesCommon fault types

Page 8: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

General Introduction

Analyzing the Alarm Information

Alarm information come from the RAN alarm system, indicated

usually through sound, light, LED, and screen output, etc

It includes the detailed description of the abnormality, possible

causes and restoration suggestions, involves the hardware, link,

trunk and CPU loading ratio, etc.. It is a gist for the fault analysis

and location

Analyzing the Indicator Status

Indicators can indicate the work status of circuit, link, optical path,

node and active/standby mode besides that of the corresponding

boards, usually used along with the alarm information generally

Analyzing Traffic Statistics Result

It is the most useful method for locating RNO fault.

Basic Basic troubleshootingtroubleshooting method methodss

Page 9: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

General Introduction

Analyzing Apparatus & Meter Test Result

It reflects the fault nature with the visual and quantified data

Some common Apparatus & Meter

− Signaling Analyzer, Test phone, Sitemaster, etc.

Tracing the Interface

It is applied in locating the failure causes of subscriber call connection an

d inter-office signaling cooperation, etc.

The trace result can help to find the cause of call failure directly and locat

e the problem or to get the index for the subsequent analysis

Traffic Test

It is a simple and quick method to judge whether the call processing func

tion and relative modules of the RAN are normal or not

Basic Basic troubleshootingtroubleshooting method methodss

Page 10: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

General Introduction

Comparison/Interchange

Comparison: compare the faulted components or phenomenon with the

normal ones, and find the differences so as to find the problem

− It is usually used in the situation with simple fault range

Interchange: if the fault can not be located even after the standby

components are replaced, you can interchange the normal components

(such as board, optical fiber, etc.) with the potential faulted components,

and to compare the work status so as to specify the fault range or part

− It is usually used in the situation with complicated fault range

Switching/Resetting

It can not locate the fault cause accurately, and due to the randomness of

software running, the fault may be not able to recur, thus it is difficult to

know the real fault and solve the problem

This method is just an emergency method, applicable only in the

emergent situation

Basic Basic troubleshootingtroubleshooting method methodss

Page 11: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

General Introduction

Contacting the Technical Support Engineers of Huawei

Before you call, please collect information as follow

Detailed name of the office or site

Linkman and telephone

Time of fault occurring

Software version of the office or site

Detailed description of fault

Alarm files, interface tracing files, traffic statistic result

Actions performed after the fault’s occurring and the results

Problem level and the time you wish to solve the problem

Basic Basic troubleshooting troubleshooting methodmethodss

Page 12: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

Summary General Procedures of Troubleshooting

Finding fault- >Judging Fault- >locating fault- >Removing Fault

Basic Methods of Fault Judgement and Location

For simple fault

− Analyzing the Alarm Information and the Indicator status

− Comparison/Interchange

For complex fault

− Analyzing Traffic Statistics Result

− Analyzing Apparatus and Meter Test Result

− Tracing the Interface, Traffic Test

For restoring system

− Switching/Resetting

Page 13: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

Chapter 1 General IntroductionChapter 1 General Introduction

Chapter 2 Typical CasesChapter 2 Typical Cases

Chapter 3 NodeB Fault PreventionChapter 3 NodeB Fault Prevention

Page 14: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

Chapter 2 Typical CasesChapter 2 Typical Cases

2.1 Transmission Faults2.1 Transmission Faults

2.22.2 Operation and Maintenance Operation and Maintenance FaultsFaults

2.3 Cell Faults2.3 Cell Faults

Page 15: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

Transmission FaultsTransmission Faults

RAN Transport Network

RAN transport network

2.5G/ 622M/ 155M

2M/34M

PDH

155M

155M

NodeB

Microwave

NodeB

RNCRNC NodeB

NodeB NodeB

NodeB

NodeB

NodeB

OptiX

NodeB

OptiXOptiX

OptiX

OptiX

NodeB

DSL

NodeBNodeB

NodeBLMDS

Synchronal network

Page 16: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

Transmission Broken

− Transmission device, board or E1 is faulty

▪ More transmission device, more fault

− Transmission code is different (use CRC4 or not)

High BER (bit error rate)

− Microwave, HDSL transmission, especially in rainy weather

− E1 connection quality is bad

▪ It will cause bad quality, even transmission broken

− The grounding system is faulty

Transmission FaultsTransmission FaultsPhenomena and CausesPhenomena and Causes

Page 17: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

Case1: E1 Broken (to be continued )Transmission Faults

Description E1 broken,E1 having alarm

Troubleshooting methods This could be due to interface board faulty, E1 port faulty or E1

cable faulty

1. Check for alarm on the board and E1 port

DSP BRD

DSP E1T1

If board is faulty, then replace board

2. Board not faulty, but E1 port having alarm. Perform loop back test on local end

SET E1T1LOP ( Loopback Type = LOCAL )

LOP E1T1 ( RNC )DSP E1T1 ( NodeB )SET E1T1LOP ( Loopback Type = NOLOOP)

If E1 port is faulty, then replace board

Page 18: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

TX

RX

RX

TXRNC NodeB

Step 2: Local Loop Back>> SET E1T1LOP (Loop type=local)>> DSP E1T1

Step 2: Local Loop Back>> SET E1T1LOP (Loop type=local)>> LOP E1T1 (Activate loop)>> SET E1T1LOP (Loop type=noloop)

Step 3: Remote Loopback>> DSP E1T1

Step 3: Remote Loopback>> SET E1T1LOP (Loop type=remote)

Step 1: Check Board and ports>> DSP BRD >> DSP E1T1

Step 1: Check Board and ports>> DSP BRD >> DSP E1T1

Case1: E1 Broken (continued) Transmission Faults

Troubleshooting methods

3. Board not faulty, E1 port not fault ,but alarm being in exist

ence then perform loop back on far end and monitor at R

NC

SET E1T1LOP (Loop type=remote)

DSP E1T1 ( RNC )

If transport network is fault, then examine cable and devic

e

Transport network

Page 19: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

Chapter 2 Typical CasesChapter 2 Typical Cases

2.1 Transmission Faults2.1 Transmission Faults

2.22.2 Operation and Maintenance Operation and Maintenance FaultsFaults

2.3 Cell Faults2.3 Cell Faults

Page 20: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved

Operation and Maintenance System Faults

NodeB provides two modes of operation and

maintenance

− Near end operation and maintenance

− Far end operation and maintenance

Fundamental Knowledge

RNC

SNTP Server

M2000

Subnet 2 Subnet 3

IPoA local IP

IPoA Peer IP

RNC BAM IP

Subnet 5

Subnet 4

LMT 2

LMT1

Subnet 1

BTS3812E

NMPT EthernetPort IP address

Page 21: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

Case1: Downloading Software Package Lasts Too Long,Sometimes Software Downloading Fails

Operation and Maintenance System Faults

Description

In the course of software upgrading, it takes several hours to

download the software package, and sometimes, the

software downloading procedure fails

Page 22: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

Case1: Downloading Software Package Lasts Too Long, Sometimes Software Downloading Fails

Operation and Maintenance System Faults

Troubleshooting methods

For maintenance over IPoA through RNC, check whether the IPoA bandwidth on RNC Operation and Maintenance system is too narrow

Increase the IPoA bandwidth to speed up software downloading progress based on the actual situation.

Page 23: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

Case2: Fail to Log in to NodeB by Near End Mode

Operation and Maintenance System Faults

Description

In near end maintenance mode, the Operation and Maintenan

ce system can log in to NodeB normally before downloading

data configuration file. When NodeB restarts after the data co

nfiguration file downloading procedure finishes, the Operation

and Maintenance system cannot log in to NodeB by near end

mode, but can log in to it over IPoA. In this case, board indica

tors are normal.

Page 24: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

Case2: Fail to Log in to NodeB by Near End ModeOperation and Maintenance System Faults

Troubleshooting methods

The reason for this fault may be incorrect setting of IP address of near end maintenance channel

− Step 1: Log in to NodeB over IPoA link through Operation and Maintenance system, configure IP for near end maintenance channel by using the MML command SET IP. Query whether the setting is successful by using the MML command LST IP.

− Step 2: Open the data configuration file on the configuration management system to modify the NodeB property. Modify the local IP address as the value demanded, download the data configuration file again, and then restart the NodeB.

Page 25: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

Chapter 2 Typical CasesChapter 2 Typical Cases

2.1 Transmission Faults2.1 Transmission Faults

2.22.2 Operation and Maintenance Operation and Maintenance FaultsFaults

2.3 Cell Faults2.3 Cell Faults

Page 26: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

Cell FaultsFundamental Fundamental

KnowledgeKnowledge

NBAP_AUDIT_REQ

NBAP_CELL_SETUP_REQ

NBAP_CELL_SETUP_RSP

NBAP_COMM_TRANSP_CH_SETUP_REQ

NBAP_COMM_TRANSP_CH_SETUP_RSP

NBAP_SYS_INFO_UPDATE_REQ

NBAP_SYS_INFO_UPDATE_RSP

NBAP_AUDIT_RSP

NodeB RNC

Page 27: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

Case1: No CELL SETUP REQUEST Message from RNC While NodeB in Normal State

Cell Faults

Description

The logical cell cannot be setup. When you perform query with

MML command on NodeB Operation and Maintenance syste

m, the local cell resources are available, and both NCP and C

CP states are normal. Upon receipt the request of resource au

dit from NodeB Operation and Maintenance system by MML c

ommand ADT RES, RNC delivers only a resource audit comm

and but no CELL SETUP REQUEST message

Page 28: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

Cell Faults

Troubleshooting methods

Check whether the maximum downlink power reported by

NodeB in the audit message is smaller than the value con

figured by RNC.

On NodeB Operation and Maintenance system, use the

MML command DSP CELL to view whether the local cell I

D is consistent with that specified in RNC

Case1: No CELL SETUP REQUEST Message from RNC While NodeB in Normal State

Page 29: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

Case2: Cell Deleted and Setup Repeatedly, RNC Multi-Frame Out-of-Synchronization Alarm Occurs, Cell Setup Fails

Cell Faults

Description

From the message traced by Iub interface, cell is deleted and set

up repeatedly. At the same time, there are multi-frame out-of-syn

chronization alarms unable to be cleared in RNC. But E1 cable st

ate is available when queried by the MML command DSP E1T1 o

n NodeB Operation and Maintenance system

Page 30: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

Case2: Cell Deleted and Setup Repeatedly, RNC Multi-Frame Out-of-Synchronization Alarm Occurs, Cell Setup Fails

Cell Faults

Troubleshooting methods

The most possible cause for this fault is that E1 working

mode for NodeB is not consistent with that for RNC: dual-

frame for NodeB, and multi-frame for RNC.

Page 31: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

Case3: Only One Cell Can Be Setup due to Modification of Cell Radius

Cell Faults

Description

Originally, cell 0 and cell 2 can be setup normally. After

the radius of both cell 0 and cell 2 is modified from

256*78 m to 1536*78 m, cell 2 is failed to setup. The

local cell is unavailable due to lack of baseband

resources according to the query result with the

corresponding MML command.

Page 32: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

Case3: Only One Cell Can Be Setup due to Modification of Cell Radius

Cell Faults

Troubleshooting methods

The fault must be caused by lack of access

resources. A set of access resources includes an

access ASIC and an access DSP. When the cell

radius is smaller than or equal to 384*78 m, a set of

access resources can support three cells. When the

cell radius is greater than 384*78 m, it can support

only one cell.

Page 33: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

Case4: RNC Deletes Cell after NodeB Responds with Cell and Common Transport Channel Setup

Cell Faults

Description

RNC sends a CELL SETUP REQUEST message to No

deB, and NodeB reports a CELL SETUP RESPONSE m

essage to RNC. Then RNC sends two COMMON TRAN

SPORT CHANNEL SETUP REQUEST messages. Upon

receipt of the two COMMON TRANSPORT CHANNEL

SETUP RESPONSE messages from NodeB, the RNC s

ends a CELL DELETION REQUEST message instead o

f a SYSTEM INFORMATION UPDATE REQUEST mess

age. There is no alarm in NodeB or RNC

Page 34: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

Case4: RNC Deletes Cell after NodeB Responds with Cell and Common Transport Channel Setup

Cell Faults

Troubleshooting methods

The fault may be relative to Iub interface user pla

ne. In this case, it is necessary to check the user

plane of NodeB and RNC in data configuration a

nd hardware connection to see whether they are

consistent.

Page 35: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

Chapter 1 General IntroductionChapter 1 General Introduction

Chapter 2 Typical CasesChapter 2 Typical Cases

Chapter 3 NodeB Fault PreventionChapter 3 NodeB Fault Prevention

Page 36: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

NodeB Fault Prevention

Page 37: 5 NodeB Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

NodeB Fault Prevention

Hardware: installation specifications are most important

Pay more attention to E1 connector

Pay more attention to feeder connector

Pay more attention to the waterproofer of antenna and feeder

system

Confirm the grounding and lightning protection

Checking Running status

NodeB maintenance console

− First, do “multi-site fault query”,

− Then, try to remove the fault according to the alarm descri

ption and suggestion

− If you cannot remove the fault provisionally, confirm the re

ason of every fault at least

Page 38: 5 NodeB Troubleshooting

www.huawei.com

Thank You