004 service report 1250 g07020 may 2015
-
Upload
fargo2015 -
Category
Engineering
-
view
74 -
download
0
Transcript of 004 service report 1250 g07020 may 2015
Service Report Onsite Repairs
004
Customer / site Electrocentro / San Francisco
Contact person Ing. Jimmy Quispe C. Date 22/05/2015Description repair/fault Change breaker ABB, hose,
fan, lamp, racor bottle and painting genset
Setnumber 1250G07020
kVA 1250Running hours 8702
Description work
Alternator, container, fuel hose, power cables, all burned
Pictures before (if possible)
Service Report Onsite Repairs
004
Service Report Onsite Repairs
004
Service Report Onsite Repairs
004
Pictures after (if possible)
Water hose 1 changed
Water hose 2 changed
Service Report Onsite Repairs
004
Fuel hose return changed
Fuel hose in and return, changed
Service Report Onsite Repairs
004
Power cable with vulcanizing tape and electrical tape
Bottom changed
Fan motor changed
Service Report Onsite Repairs
004
Lamp´s inside changed
Fuel valve changed
Fuel hose download from truck, changed
Service Report Onsite Repairs
004
Bottom changed
Breaker generator changed
Racor´s bottle changed
Service Report Onsite Repairs
004
Used parts:Breaker ABBRacor´s bottleBottom preheaterBottom internalLamp,Water hoseFuel hose in and returnFan motor internal side rightFuel hose download from truckFuel valvePower cable
Labour time/ man hours:
hours Name engineer(s): Jimmy Quispe
Transport time: days Crane hours: 0
Amount KM’s: km Other costs: 0
Remarks:Need clean bus-bar alternator with SS25