Available on CMS information server CMS IN 2005/046 CMS Internal Note The content of this note is intended for CMS internal use and distribution only October 27, 2005 HF Readout Box Production and Final Tests Nural Akchurin, Kenneth Carrell, Kazim G¨ um¨ s, Heejong Kim and Mario Spezziga Texas Tech University, Department of Physics, Lubbock, Texas, USA Abstract The design of the CMS forward calorimeter (HF) Readout Boxes (RBXs) was finalized after the beam tests in 2003. These readout enclosures, referred to as RBXs, contain 24 photo- multiplier tubes with the associated high voltage circuit boards, light mixing and distribution systems for monitoring. All 72 RBXs were assembled and tested at Texas Tech University between May 2004 and May 2005. The RBX assembly and testing procedures are described in this note. Summary tables that contain tower assignments, gain and afterpulse measurements for each PMT for all RBXs are appended at the end.

Transcript of heejong/ref/in05_046.pdf

Available on CMS information server CMS IN 2005/046

CMS Internal NoteThe content of this note is intended for CMS internal use and distribution only

October 27, 2005

HF Readout Box Production and Final Tests

Nural Akchurin, Kenneth Carrell, Kazim Gumus, Heejong Kim and Mario Spezziga

Texas Tech University, Department of Physics, Lubbock, Texas, USA

Abstract

The design of the CMS forward calorimeter (HF) Readout Boxes (RBXs) was finalized afterthe beam tests in 2003. These readout enclosures, referred to as RBXs, contain 24 photo-multiplier tubes with the associated high voltage circuit boards, light mixing and distributionsystems for monitoring. All 72 RBXs were assembled and tested at Texas Tech Universitybetween May 2004 and May 2005. The RBX assembly and testing procedures are described inthis note. Summary tables that contain tower assignments, gain and afterpulse measurementsfor each PMT for all RBXs are appended at the end.

1 Introduction

The details of the readout box design for the CMS forward calorimeters (HF) were finalized after thebeam tests in the summer of 2003 [1]. This design has been evolving over the years and the main designcriteria are detailed in previous notes [2, 3]. Within a year (May 2004 to May 2005), the constructionand testing of all 76 (72 + 4 spares) RBXs were completed at TTU. An automated test-stand enabledus to measure the gains and afterpulse levels of all PMTs individually. The RBXs were also thoroughlychecked for light leaks. Individual light injection capability to a selected PMT via moving source fiber,to ensure correct cabling inside the RBX, also proved essential. All data from these tests are storedand published [1]. The most relevant data are tabulated in a condensed form at the end of this note inAppendix

17 RBXs were constructed and shipped to CERN for the 2004 summer beam tests. The remaining 55RBXs were completed in the fall of 2004 and the spring of 2005.

2 Assembly

There are 1728 PMT channels for the HF. Per side (HF+ and HF-), 864 PMTs are grouped into 36RBXs with 24 PMTs each. Each RBX services 10o of the calorimeter in azimuth. The PMT gainswere measured at the University of Iowa before shipment to TTU. These values were reported relativea reference PMT with a gain of 6.4 × 104 operated at −1100 V. PMTs were sorted at TTU into threegain groups: low, middle and high. 8 PMTs from each group were mounted on a single high voltageboard (HVB). Three HVBs with 24 PMTS were then inserted into soft iron tubes designed for magneticshielding. In combination with these soft iron tubes and the mu-metal shields provided by Hamamatsu,PMTs are well-shielded against external magnetic fields up to ∼ 400 Gauss. After completing the high-voltage and signal cabling inside the RBX, an aluminum case was used to hermetically house the entiresystem. Figure 1 shows the major stages in the assembly and testing.

Figure 1: Eight PMTs are mounted in an high voltage board (HVB) (top left). Three HVB with 24 PMTsare inserted into soft iron magnetic shields (top right). An RBX is fully assembled (bottom left). Notethe signal (D-sub) and the HV (Kerpen) connectors, in addition to the nitrogen input (Legris connector)and the light injection SMA connector at a 45-degree angle (red capped). One of the RBX is mountedon the test station at TTU where the signal and HV cables are connected for tests (bottom right).

2

3 RBX Test Setup

A CAEN N472 unit supplied the nominal high voltage of –1350 V for all tests after the 2004 summerbeam tests. The high voltage was distributed through a custom fan-out module built at Iowa StateUniversity [4]. 17 RBXs (numbered 2, 3, 4, 15, 16, 39, 40, 43, 44, 47, 48, 61, 62, 63, 64, 71 and 72),which were built for the 2004 summer beam tests at CERN, were tested at 3 different high voltage values(–1180 V for HVB1, –1390 V for HVB2 and –1720 V for HVB3). All other RBXs were tested at a singlevoltage of –1350 V for all three HVBs.

A blue Nichia LED served as the light source and was driven by a 25 ns square pulse at 1 KHz. LEDwas coupled to a quartz optical fiber (so-called source fiber) and could be moved in both vertical andhorizontal directions by a computer to perfectly align with another fiber which was used to illuminatea single PMT in an RBX. After taking data from a PMT, the source fiber would be moved to the nextfiber until all 24 PMTs were completed. This procedure ensured correct cabling inside the RBXs.

The signals from PMTs were amplified by a fast amplifier (Lecroy 612A) and fanned out to 4 ADCs(Lecroy 2249W). The other split signals were fed to discriminators (Lecroy 623B at 40 mV threshold)to measure the afterpulse timing with TDCs (Lecroy 2228A and 3377). The digitized data were readoutthrough a VME-CAMAC controller to a Linux computer. Figure 2 schematically shows the setup.Figure 3 displays the inside view of the light-tight box where the source and the other fibers can clearlybe seen.

HV

Pulse Generator

LED

ADC TDCTest Station

DiscriminatorAmplifier

Linux PC

Light Shielded Box

RBX

Figure 2: The schematic diagram of the RBX test setup at TTU shows the major components.

4 Test Results

4.1 PMT gain

Figures 4, 5 and 6 show the ADC distributions for 24 PMTs in RBX11, as an example, for the low, mediumand high gain groups, respectively. The light distribution system shown in Figure 3 was calibrated priorto these tests such that a multiplicative factor for each channel was determined to ensure equal response.The uniformity of light transportation between channels was better than 10%. After these corrections,the mean values of 24 PMTs were plotted as in Figures 7 and 8, for RBX11 and RBX12, respectively.The main difference between Figures 7 and 8, as intended, is the ordering of PMTs according to theirgain values. The mean and rms values of ADC distribution for all PMTs are listed in the Appendix.

4.2 Afterpulse of PMT

We reported last year that there were significant levels of afterpulses in a number of PMTs. We includedthese data routinely in the travelers for a possible future need. For example, Figure 10 shows afterpulse

3

Figure 3: A RBX is mounted on the test station on top of the light-tight box where the fiber lightdistribution system is located (left). Quartz fibers (2×24) which terminate at individual PMTs are gluedto an aluminum plate (top right). The optical fiber coupled to a LED (source fiber) is precisely alignedwith one of the fibers that illuminate a PMT (bottom right).

Quadrant Fiber Section Low Eta Medium Eta High EtaHF+ Q1 S 103.0±0.6 87.0±0.6 67.0±1.1

L 164.0±1.1 140.0±0.7 123.0±0.6HF+ Q2 S 106.0±0.6 91.0±0.6 73.0±0.5

L 173.0±1.2 147.0±0.9 127.0±0.5HF+ Q3 S 111.0±0.6 95.0±0.5 78.0±0.8

L 182.0±1.2 152.0±0.8 132.0±0.6HF+ Q4 S 116.0±0.5 99.0±0.5 83.0±0.7

L 197.0±3.0 157.0±1.0 136.0±0.7HF– Q1 S 105.0±0.3 89.0±0.6 71.0±0.9

L 168.0±1.1 143.0±1.0 125.0±0.6HF– Q2 S 109.0±0.6 92.0±0.7 75.0±0.6

L 178.0±1.9 149.0±0.8 129.0±0.8HF– Q3 S 113.0±0.9 97.0±0.8 80.0±0.6

L 188.0±2.3 155.0±0.8 134.0±0.6HF– Q4 S 118.0±0.7 101.0±0.6 85.0±0.7

L 206.0±2.3 161.0±0.9 138.0±0.7

Table 1: Average gain values (and the standard deviation) for each quadrant are given in relative units(see Figure 9). The gain value of 100 corresponds to 6.4 × 104.

behavior of a PMT (L14) in RBX11. Typically afterpulses take place a few hundred nanoseconds afterthe main pulse, and are caused by the residual gases inside PMT. In R7525s, we observe three distinctafterpulses (Figure 10.b). With respect to the leading edge of the main pulse the afterpulses are at ∼170,∼330 and ∼650 ns. These peaks are due to H+, He+ and possibly CH+

4 or other ions like N+, O+,

4

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

800

BOX# 11 : E24 : Main_P : CH_ 0

Entries 10000Mean 153.9RMS 20.06Integral 9999

/ ndf 2χ 222.6 / 33Constant 8.2± 651.6 Mean 0.2± 153.9 Sigma 0.15± 19.95

BOX# 11 : E24 : Main_P : CH_ 0

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

1200

1400

1600

BOX# 11 : H24 : Main_P : CH_ 1

Entries 10000Mean 82.49RMS 10.47Integral 1e+04

/ ndf 2χ 201.2 / 16Constant 15.6± 1259 Mean 0.11± 82.46 Sigma 0.08± 10.35

BOX# 11 : H24 : Main_P : CH_ 1

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

BOX# 11 : E13 : Main_P : CH_ 2

Entries 10000Mean 168.9RMS 21.42Integral 9999

/ ndf 2χ 257.5 / 36Constant 7.7± 613.9 Mean 0.2± 168.8 Sigma 0.16± 21.09

BOX# 11 : E13 : Main_P : CH_ 2

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

BOX# 11 : H13 : Main_P : CH_ 3

Entries 10000Mean 97.79RMS 13.31Integral 9999

/ ndf 2χ 267.6 / 21Constant 12.4± 987.2 Mean 0.14± 97.68 Sigma 0.10± 13.09

BOX# 11 : H13 : Main_P : CH_ 3

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

BOX# 11 : E23 : Main_P : CH_ 4

Entries 10000Mean 167.7RMS 21.33Integral 1e+04

/ ndf 2χ 223.3 / 35Constant 7.8± 621.1 Mean 0.2± 167.5 Sigma 0.2± 20.9

BOX# 11 : E23 : Main_P : CH_ 4

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

1200

1400

BOX# 11 : H23 : Main_P : CH_ 5

Entries 10000Mean 77.26RMS 11.23Integral 9999

/ ndf 2χ 223.2 / 17Constant 14.7± 1170 Mean 0.12± 77.16 Sigma 0.08± 11.11

BOX# 11 : H23 : Main_P : CH_ 5

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

BOX# 11 : E22 : Main_P : CH_ 6

Entries 10000Mean 183.2RMS 23.03Integral 9999

/ ndf 2χ 247.9 / 39Constant 7.1± 568.9 Mean 0.2± 183 Sigma 0.17± 22.78

BOX# 11 : E22 : Main_P : CH_ 6

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

BOX# 11 : H22 : Main_P : CH_ 7

Entries 10000Mean 110.1RMS 14.1Integral 1e+04

/ ndf 2χ 263.3 / 23Constant 11.7± 929.9 Mean 0.1± 110.1 Sigma 0.11± 13.92

BOX# 11 : H22 : Main_P : CH_ 7

Figure 4: Distributions of ADC readout of 8 low gain PMTs in RBX11.

etc. The relative abundance of these three afterpulses (noted as AP1, AP2 and AP3) are different foreach PMT; however, the third one is generally the most dominant. The charge distribution of AP3 isshown in Figure 10.a. Figure 10.c shows AP3 charge as a function of the main pulse in ADC counts (0.25pC/count). As expected, the afterpulse charge is independent of the main pulse charge. On the otherhand, the afterpulse rate is linearly proportional to the main pulse, which is shown in Figure 10.d. Wedefine afterpulse rate as the fraction of events that result in afterpulses within a time window (550 to 750ns for the third afterpulse).

The afterpulse rate is defined as follows.

Afterpulse rate =# of events which has afterpulse timing hits

total # of events(1)

The afterpulse rate and charge of AP3 are listed in the Appendix. A recent detailed study on afterpulsescan be found in [5].

5 Summary

17 RBXs were used during the 2004 HF beam test without problems. Assembly of all the remainingRBXs and the final testing were completed by May 2005. During these tests, the relative gain of eachPMT was measured, and the correct mapping of PMTs to feedthrough connectors was ensured. TheRBXs were also tested for light tightness and mechanical integrity. Summary tables are included withthis note. In August 2005, all readout boxes were mounted on the HF calorimeters.

5

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

BOX# 11 : E21 : Main_P : CH_ 8

Entries 10000Mean 198.3RMS 23.93Integral 1e+04

/ ndf 2χ 218.7 / 40Constant 6.9± 547.6 Mean 0.2± 198.1 Sigma 0.18± 23.75

BOX# 11 : E21 : Main_P : CH_ 8

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

800

BOX# 11 : H21 : Main_P : CH_ 9

Entries 10000Mean 144.1RMS 18.58Integral 1e+04

/ ndf 2χ 203.9 / 31Constant 8.9± 718 Mean 0.2± 143.9 Sigma 0.13± 18.13

BOX# 11 : H21 : Main_P : CH_ 9

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

BOX# 11 : E20 : Main_P : CH_10

Entries 10000Mean 219.2RMS 27.03Integral 9999

/ ndf 2χ 266.9 / 45Constant 6.1± 482.3 Mean 0.3± 218.9 Sigma 0.21± 26.83

BOX# 11 : E20 : Main_P : CH_10

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

BOX# 11 : H20 : Main_P : CH_11

Entries 10000Mean 104.8RMS 15.51Integral 9999

/ ndf 2χ 249.5 / 25Constant 10.6± 852.2 Mean 0.2± 104.8 Sigma 0.11± 15.19

BOX# 11 : H20 : Main_P : CH_11

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

BOX# 11 : E19 : Main_P : CH_12

Entries 10000Mean 210.7RMS 27.1Integral 9999

/ ndf 2χ 249.1 / 46Constant 6.1± 482.8 Mean 0.3± 210.5 Sigma 0.20± 26.85

BOX# 11 : E19 : Main_P : CH_12

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

BOX# 11 : H19 : Main_P : CH_13

Entries 10000Mean 125.2RMS 16.38Integral 1e+04

/ ndf 2χ 218.8 / 26Constant 10.1± 804.7 Mean 0.2± 125.1 Sigma 0.12± 16.15

BOX# 11 : H19 : Main_P : CH_13

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

BOX# 11 : E18 : Main_P : CH_14

Entries 10000Mean 199RMS 24.22Integral 9999

/ ndf 2χ 192.1 / 40Constant 6.7± 541.3 Mean 0.2± 198.7 Sigma 0.18± 24.09

BOX# 11 : E18 : Main_P : CH_14

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

800

BOX# 11 : H18 : Main_P : CH_15

Entries 10000Mean 142.4RMS 18.11Integral 9999

/ ndf 2χ 227.1 / 30Constant 9.0± 725.7 Mean 0.2± 142.3 Sigma 0.13± 17.91

BOX# 11 : H18 : Main_P : CH_15

Figure 5: Distributions of ADC readout of 8 middle gain PMTs in RBX11.

ADC counts0 50 100 150 200 250 300 350 400

0

50

100

150

200

250

300

350

400

450

BOX# 11 : E17 : Main_P : CH_16

Entries 10000Mean 282.4RMS 34.49Integral 9990

/ ndf 2χ 249.6 / 59Constant 4.7± 380.6 Mean 0.4± 282.3 Sigma 0.25± 34.06

BOX# 11 : E17 : Main_P : CH_16

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

800

BOX# 11 : H17 : Main_P : CH_17

Entries 10000Mean 152.6RMS 18.5Integral 9999

/ ndf 2χ 232.1 / 30Constant 8.9± 714.6 Mean 0.2± 152.6 Sigma 0.13± 18.14

BOX# 11 : H17 : Main_P : CH_17

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

BOX# 11 : E16 : Main_P : CH_18

Entries 10000Mean 226.6RMS 29.74Integral 9999

/ ndf 2χ 242 / 51Constant 5.6± 443.8 Mean 0.3± 226.4 Sigma 0.22± 29.22

BOX# 11 : E16 : Main_P : CH_18

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

BOX# 11 : H16 : Main_P : CH_19

Entries 10000Mean 127.2RMS 16.14Integral 1e+04

/ ndf 2χ 200.9 / 26Constant 10.3± 817.2 Mean 0.2± 127 Sigma 0.12± 15.94

BOX# 11 : H16 : Main_P : CH_19

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

BOX# 11 : E15 : Main_P : CH_20

Entries 10000Mean 218RMS 28.96Integral 9999

/ ndf 2χ 249.6 / 49Constant 5.7± 452.4 Mean 0.3± 217.7 Sigma 0.22± 28.66

BOX# 11 : E15 : Main_P : CH_20

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

BOX# 11 : H15 : Main_P : CH_21

Entries 10000Mean 168.5RMS 21.5Integral 1e+04

/ ndf 2χ 236.2 / 36Constant 7.7± 615.1 Mean 0.2± 168.4 Sigma 0.16± 21.09

BOX# 11 : H15 : Main_P : CH_21

ADC counts0 50 100 150 200 250 300 350 400

0

100

200

300

400

500

600

700

BOX# 11 : E14 : Main_P : CH_22

Entries 10000Mean 197.4RMS 24.96Integral 1e+04

/ ndf 2χ 269.6 / 42Constant 6.6± 529 Mean 0.3± 197.2 Sigma 0.18± 24.42

BOX# 11 : E14 : Main_P : CH_22

ADC counts0 50 100 150 200 250 300 350 400

0

200

400

600

800

1000

BOX# 11 : H14 : Main_P : CH_23

Entries 10000Mean 117.7RMS 16.02Integral 1e+04

/ ndf 2χ 302.6 / 26Constant 10.4± 819.5 Mean 0.2± 117.5 Sigma 0.12± 15.72

BOX# 11 : H14 : Main_P : CH_23

Figure 6: Distributions of ADC readout of 8 high gain PMTs in RBX11.

6

CH#0 5 10 15 20

AD

C c

ount

s

0

50

100

150

200

250

300

RBX #_11 : Charge(corrected) vs CH#RBX #_11 : Charge(corrected) vs CH#

CH#0 5 10 15 20

AD

C c

ount

s

0

50

100

150

200

250

300

RBX #_11 : Charge(corrected) vs CH#

Figure 7: Comparison of mean gain values for all 24 PMTs in RBX11. Note that low, medium and highgain PMTs are grouped as indicated by arrows. Within a group of 8 PMTs, higher and lower gains arefor L and S fiber sections, respectively.

CH#0 5 10 15 20

AD

C c

ount

s

0

50

100

150

200

250

RBX #_12 : Charge(corrected) vs CH#RBX #_12 : Charge(corrected) vs CH#

CH#0 5 10 15 20

AD

C c

ount

s

0

50

100

150

200

250

RBX #_12 : Charge(corrected) vs CH#

Figure 8: Comparison of mean gain values for all 24 PMTs in RBX12. Note that low, medium and highgain PMTs are grouped as indicated by arrows. Within a group of 8 PMTs, higher and lower gains arefor L and S fiber sections, respectively.

7

Figure 9: RBXs are mounted onto the HF+ and HF- detectors as shown above. In the case of HF-, theRBXs numbers are such that 1 → 37, 2 → 38, . . . , 36 → 72. See Table 1 for average PMT gain groups foreach quadrant.

8

ADC counts0 20 40 60 80 100

0

50

100

150

200

250

300

350

BOX# 11 : E14 : Afterpulse : CH_22

Entries 2611

Mean 47.52

RMS 13.76

Integral 2598

(a)

BOX# 11 : E14 : Afterpulse : CH_22

ns0 100 200 300 400 500 600 700 800 900 1000

0

20

40

60

80

100

120

140

160

BOX# 11 : E14 : Timing of Afterpulse : CH_22

Entries 4158

Integral 4158(b)

BOX# 11 : E14 : Timing of Afterpulse : CH_22

Main Pulse120 140 160 180 200 220 240 260 280

Afte

rpul

se

35

40

45

50

55

BOX# 11 : E14 : Main pulse vs Afterpulse : CH_22

(c)

BOX# 11 : E14 : Main pulse vs Afterpulse : CH_22

Main Pulse140 160 180 200 220 240 260

Afte

rpul

se R

ate(

%)

10

20

30

40

50

BOX# 11 : E14 : Afterpulse Rate : CH_22

(d)

BOX# 11 : E14 : Afterpulse Rate : CH_22

Figure 10: The afterpulse charge (a); time distribution (b); and the dependence of afterpulse charge (c);and rate (d) to the main pulse for channel L22 in RBX11 are included as part of the traveller.

9

6 Appendix: Summary Tables

The listed parameters in the tables are:

• Tower is the tower assignment for a given PMT in a wedge. L refers to the long and S refers tothe short fiber sections. Note that there are two different types (odd and even numbered RBXs) ofPMT arrangements in RBXs as shown in Figures 7 and 8.

• ADC Ch. refers to the ADC channel number that a PMT was connected during the TTU tests.

• HVB is high voltage board ID for low, middle and high gain PMTs and simply identifies low, mediumand high gain groups.

• Serial No is the manufacturer’s (Hamamatsu) serial number.

• UI Gain refers to the gain measured at University of Iowa. This value is normalized to a referencePMT operated at −1100 V with a gain of 5 × 105.

• TTU Gain is the mean of the charge distribution (in ADC counts) as tested at TTU after thePMTs are assembled in RBXs. The quoted value is mean ± rms. One ADC count is 0.25 pC.

• AP3 Charge refers to the afterpulse charge within 550 – 750 ns time interval as in Figure 10(b).The values are reported as mean ± rms.

• AP rate refers to specifically the AP3 afterpulse rate. The values are in percentage with theestimated error. There is no afterpulse information on the RBXs that were shipped to CERN priorto 2004 summer beam tests.

10

Tower ADC Ch. HVB HV Serial No UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1623 122 124 ± 19 35 ± 11 14.4 ± 0.4S24 2 1 1350 535 65 65 ± 9 23 ± 6 2.8 ± 0.2L13 3 1 1350 1746 122 139 ± 20 43 ± 15 34.6 ± 0.6S13 4 1 1350 1994 65 59 ± 9 20 ± 5 6.8 ± 0.3L23 5 1 1350 1349 121 130 ± 19 39 ± 13 21.8 ± 0.5S23 6 1 1350 495 65 66 ± 11 21 ± 5 3.3 ± 0.2L22 7 1 1350 962 121 130 ± 19 35 ± 11 14.7 ± 0.4S22 8 1 1350 420 65 64 ± 10 23 ± 7 14.9 ± 0.4L21 9 2 1350 2202 139 131 ± 18 39 ± 13 30.5 ± 0.6S21 10 2 1350 599 86 86 ± 13 27 ± 9 28.5 ± 0.5L20 11 2 1350 1163 139 144 ± 21 43 ± 14 30.6 ± 0.6S20 12 2 1350 345 86 82 ± 14 27 ± 8 2.6 ± 0.2L19 13 2 1350 1298 139 137 ± 20 24 ± 14 37.8 ± 0.6S19 14 2 1350 881 86 82 ± 12 16 ± 8 23.5 ± 0.5L18 15 2 1350 1906 139 117 ± 16 25 ± 11 19.9 ± 0.4S18 16 2 1350 646 85 93 ± 14 20 ± 9 26.4 ± 0.5L17 17 3 1350 2230 162 145 ± 20 26 ± 13 26.7 ± 0.5S17 18 3 1350 665 102 113 ± 16 21 ± 10 16.7 ± 0.4L16 19 3 1350 70 162 168 ± 25 28 ± 11 5.7 ± 0.2S16 20 3 1350 871 102 100 ± 15 22 ± 9 28.4 ± 0.5L15 21 3 1350 2271 162 140 ± 21 33 ± 12 22.5 ± 0.5S15 22 3 1350 2040 102 94 ± 13 14 ± 6 3.8 ± 0.2L14 23 3 1350 1518 162 151 ± 22 47 ± 13 32.9 ± 0.6S14 24 3 1350 1653 102 93 ± 15 22 ± 6 9.6 ± 0.3

Table 2: RBX 1

11

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 306 66 154 ± 6 N/A N/AL11 2 1 1180 1846 122 249 ± 10 N/A N/AS12 3 1 1180 1318 66 137 ± 6 N/A N/AL12 4 1 1180 1471 122 285 ± 12 N/A N/AS9 5 1 1180 805 65 152 ± 7 N/A N/AL9 6 1 1180 1587 122 241 ± 11 N/A N/A

S10 7 1 1180 586 65 145 ± 6 N/A N/AL10 8 1 1180 159 122 259 ± 12 N/A N/AS7 9 2 1390 376 86 268 ± 10 N/A N/AL7 10 2 1390 1444 140 387 ± 16 N/A N/AS8 11 2 1390 536 86 250 ± 10 N/A N/AL8 12 2 1390 938 140 360 ± 17 N/A N/AS5 13 2 1390 658 86 241 ± 10 N/A N/AL5 14 2 1390 2009 139 355 ± 15 N/A N/AS6 15 2 1390 1049 86 229 ± 9 N/A N/AL6 16 2 1390 1258 139 344 ± 15 N/A N/AS3 17 3 1720 2114 102 299 ± 12 N/A N/AL3 18 3 1720 1747 163 627 ± 23 N/A N/AS4 19 3 1720 1974 102 318 ± 14 N/A N/AL4 20 3 1720 2345 163 518 ± 22 N/A N/AS1 21 3 1720 1882 102 291 ± 13 N/A N/AL1 22 3 1720 739 163 602 ± 24 N/A N/AS2 23 3 1720 453 102 349 ± 16 N/A N/AL2 24 3 1720 1545 163 543 ± 27 N/A N/A

Table 3: RBX 2

12

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 2418 122 279 ± 11 N/A N/AS24 2 1 1180 1004 67 159 ± 6 N/A N/AL13 3 1 1180 1521 122 313 ± 12 N/A N/AS13 4 1 1180 343 66 174 ± 6 N/A N/AL23 5 1 1180 2184 122 241 ± 10 N/A N/AS23 6 1 1180 2103 66 153 ± 7 N/A N/AL22 7 1 1180 1928 122 278 ± 11 N/A N/AS22 8 1 1180 490 66 152 ± 7 N/A N/AL21 9 2 1390 2270 140 425 ± 17 N/A N/AS21 10 2 1390 814 86 379 ± 15 N/A N/AL20 11 2 1390 1590 140 486 ± 17 N/A N/AS20 12 2 1390 1242 86 303 ± 14 N/A N/AL19 13 2 1390 1507 140 496 ± 18 N/A N/AS19 14 2 1390 218 86 314 ± 14 N/A N/AL18 15 2 1390 990 140 460 ± 17 N/A N/AS18 16 2 1390 678 86 279 ± 11 N/A N/AL17 17 3 1720 2262 163 545 ± 20 N/A N/AS17 18 3 1720 1969 102 381 ± 13 N/A N/AL16 19 3 1720 2268 163 576 ± 23 N/A N/AS16 20 3 1720 484 102 415 ± 16 N/A N/AL15 21 3 1720 2228 163 619 ± 24 N/A N/AS15 22 3 1720 795 102 479 ± 17 N/A N/AL14 23 3 1720 2148 163 580 ± 23 N/A N/AS14 24 3 1720 1236 102 399 ± 16 N/A N/A

Table 4: RBX 3

13

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 1046 67 172 ± 7 N/A N/AL11 2 1 1180 1270 123 295 ± 11 N/A N/AS12 3 1 1180 840 67 154 ± 6 N/A N/AL12 4 1 1180 244 123 315 ± 12 N/A N/AS9 5 1 1180 503 67 167 ± 6 N/A N/AL9 6 1 1180 1764 122 291 ± 13 N/A N/A

S10 7 1 1180 2205 67 143 ± 6 N/A N/AL10 8 1 1180 427 122 293 ± 13 N/A N/AS7 9 2 1390 2498 86 269 ± 10 N/A N/AL7 10 2 1390 979 140 539 ± 20 N/A N/AS8 11 2 1390 691 86 293 ± 10 N/A N/AL8 12 2 1390 2183 140 383 ± 17 N/A N/AS5 13 2 1390 1044 86 294 ± 11 N/A N/AL5 14 2 1390 952 140 482 ± 19 N/A N/AS6 15 2 1390 636 86 317 ± 11 N/A N/AL6 16 2 1390 1114 140 477 ± 19 N/A N/AS3 17 3 1720 1543 103 435 ± 17 N/A N/AL3 18 3 1720 1890 164 759 ± 26 N/A N/AS4 19 3 1720 1175 103 429 ± 16 N/A N/AL4 20 3 1720 2454 164 651 ± 26 N/A N/AS1 21 3 1720 1631 103 409 ± 16 N/A N/AL1 22 3 1720 2015 163 710 ± 25 N/A N/AS2 23 3 1720 2331 103 348 ± 14 N/A N/AL2 24 3 1720 1150 163 666 ± 27 N/A N/A

Table 5: RBX 4

14

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 87 123 142 ± 21 37 ± 11 11.0 ± 0.3S24 2 1 1350 301 65 65 ± 9 22 ± 6 10.2 ± 0.3L13 3 1 1350 456 123 141 ± 19 43 ± 14 39.7 ± 0.6S13 4 1 1350 319 67 78 ± 11 22 ± 5 2.4 ± 0.2L23 5 1 1350 736 123 131 ± 19 41 ± 13 32.9 ± 0.6S23 6 1 1350 2050 67 61 ± 9 19 ± 4 1.8 ± 0.1L22 7 1 1350 2125 123 118 ± 16 32 ± 9 10.7 ± 0.3S22 8 1 1350 322 67 73 ± 10 23 ± 6 2.9 ± 0.2L21 9 2 1350 1169 140 155 ± 20 43 ± 14 39.8 ± 0.6S21 10 2 1350 86 87 115 ± 17 31 ± 9 10.3 ± 0.3L20 11 2 1350 1087 140 159 ± 22 39 ± 12 13.8 ± 0.4S20 12 2 1350 196 86 100 ± 17 30 ± 10 11.2 ± 0.3L19 13 2 1350 1952 140 132 ± 19 19 ± 10 19.0 ± 0.4S19 14 2 1350 419 86 91 ± 14 16 ± 7 15.9 ± 0.4L18 15 2 1350 1915 140 146 ± 20 26 ± 11 9.4 ± 0.3S18 16 2 1350 294 86 96 ± 13 17 ± 6 3.6 ± 0.2L17 17 3 1350 1812 164 201 ± 27 33 ± 17 41.0 ± 0.6S17 18 3 1350 1025 103 121 ± 16 16 ± 7 3.4 ± 0.2L16 19 3 1350 2122 164 154 ± 22 30 ± 12 24.6 ± 0.5S16 20 3 1350 556 103 126 ± 17 24 ± 9 10.6 ± 0.3L15 21 3 1350 966 164 205 ± 30 39 ± 16 24.4 ± 0.5S15 22 3 1350 1314 103 114 ± 15 17 ± 8 25.3 ± 0.5L14 23 3 1350 2060 164 149 ± 21 43 ± 11 8.6 ± 0.3S14 24 3 1350 717 103 122 ± 18 27 ± 10 25.0 ± 0.5

Table 6: RBX 5

15

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1944 68 72 ± 11 21 ± 5 4.0 ± 0.2L11 2 1 1350 1184 123 136 ± 18 38 ± 13 38.2 ± 0.6S12 3 1 1350 499 67 72 ± 10 23 ± 5 3.8 ± 0.2L12 4 1 1350 2315 123 126 ± 17 34 ± 10 14.4 ± 0.4S9 5 1 1350 530 67 71 ± 10 23 ± 5 6.3 ± 0.2L9 6 1 1350 1510 123 137 ± 20 37 ± 12 25.4 ± 0.5

S10 7 1 1350 854 67 82 ± 11 24 ± 7 15.0 ± 0.4L10 8 1 1350 2226 121 123 ± 17 35 ± 10 16.2 ± 0.4S7 9 2 1350 2090 87 82 ± 11 23 ± 6 9.6 ± 0.3L7 10 2 1350 1996 140 176 ± 23 44 ± 14 18.5 ± 0.4S8 11 2 1350 2486 87 81 ± 11 24 ± 6 7.1 ± 0.3L8 12 2 1350 1840 140 166 ± 25 45 ± 15 32.5 ± 0.6S5 13 2 1350 1884 87 84 ± 12 11 ± 6 9.1 ± 0.3L5 14 2 1350 1289 140 159 ± 22 28 ± 14 41.3 ± 0.6S6 15 2 1350 613 87 93 ± 13 24 ± 11 44.1 ± 0.7L6 16 2 1350 1036 140 163 ± 21 25 ± 11 5.0 ± 0.2S3 17 3 1350 1875 103 105 ± 15 15 ± 7 4.6 ± 0.2L3 18 3 1350 1153 165 206 ± 27 36 ± 17 40.4 ± 0.6S4 19 3 1350 891 103 97 ± 14 19 ± 7 14.2 ± 0.4L4 20 3 1350 1792 165 176 ± 24 32 ± 14 32.8 ± 0.6S1 21 3 1350 981 103 123 ± 17 26 ± 9 15.7 ± 0.4L1 22 3 1350 1704 165 199 ± 27 26 ± 12 10.4 ± 0.3S2 23 3 1350 468 103 104 ± 15 37 ± 7 3.8 ± 0.2L2 24 3 1350 1478 165 164 ± 24 31 ± 12 32.3 ± 0.6

Table 7: RBX 6

16

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1353 123 154 ± 22 39 ± 13 15.6 ± 0.4S24 2 1 1350 887 68 76 ± 10 24 ± 7 19.8 ± 0.4L13 3 1 1350 1828 123 150 ± 21 40 ± 12 24.8 ± 0.5S13 4 1 1350 336 68 80 ± 11 25 ± 6 3.0 ± 0.2L23 5 1 1350 1285 123 160 ± 22 46 ± 15 34.4 ± 0.6S23 6 1 1350 392 68 82 ± 13 22 ± 5 4.1 ± 0.2L22 7 1 1350 1502 123 149 ± 20 40 ± 13 29.9 ± 0.6S22 8 1 1350 838 68 72 ± 10 24 ± 6 10.6 ± 0.3L21 9 2 1350 2466 141 155 ± 21 38 ± 12 16.6 ± 0.4S21 10 2 1350 508 65 82 ± 11 25 ± 8 3.7 ± 0.2L20 11 2 1350 1178 141 185 ± 24 44 ± 14 24.4 ± 0.5S20 12 2 1350 1027 87 103 ± 15 27 ± 8 4.2 ± 0.2L19 13 2 1350 2300 141 142 ± 20 21 ± 12 18.2 ± 0.4S19 14 2 1350 496 87 98 ± 14 15 ± 7 8.2 ± 0.3L18 15 2 1350 2377 141 137 ± 19 27 ± 12 26.5 ± 0.5S18 16 2 1350 972 87 94 ± 13 17 ± 8 22.4 ± 0.5L17 17 3 1350 1537 165 180 ± 23 26 ± 13 32.4 ± 0.6S17 18 3 1350 1141 103 124 ± 16 23 ± 12 41.9 ± 0.6L16 19 3 1350 1612 165 172 ± 24 33 ± 14 36.0 ± 0.6S16 20 3 1350 629 103 118 ± 17 24 ± 10 25.3 ± 0.5L15 21 3 1350 1435 165 172 ± 24 35 ± 13 25.5 ± 0.5S15 22 3 1350 1330 103 133 ± 18 22 ± 11 34.7 ± 0.6L14 23 3 1350 67 165 178 ± 25 45 ± 14 5.5 ± 0.2S14 24 3 1350 1134 103 110 ± 16 24 ± 8 25.1 ± 0.5

Table 8: RBX 7

17

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 673 68 83 ± 11 24 ± 7 17.6 ± 0.4L11 2 1 1350 1508 123 156 ± 20 40 ± 13 33.5 ± 0.6S12 3 1 1350 502 68 84 ± 11 25 ± 7 15.6 ± 0.4L12 4 1 1350 1195 123 158 ± 20 45 ± 16 60.1 ± 0.8S9 5 1 1350 340 68 86 ± 11 25 ± 6 3.0 ± 0.2L9 6 1 1350 1503 123 148 ± 21 37 ± 12 31.3 ± 0.6

S10 7 1 1350 284 68 82 ± 11 23 ± 6 3.1 ± 0.2L10 8 1 1350 2166 123 140 ± 19 37 ± 12 31.3 ± 0.6S7 9 2 1350 608 87 123 ± 15 35 ± 11 38.1 ± 0.6L7 10 2 1350 46 141 185 ± 24 47 ± 15 7.7 ± 0.3S8 11 2 1350 545 87 109 ± 14 29 ± 8 4.3 ± 0.2L8 12 2 1350 998 141 194 ± 28 46 ± 16 30.1 ± 0.6S5 13 2 1350 2106 87 98 ± 13 12 ± 7 13.8 ± 0.4L5 14 2 1350 1731 141 174 ± 23 26 ± 13 22.6 ± 0.5S6 15 2 1350 360 87 113 ± 14 20 ± 7 5.8 ± 0.2L6 16 2 1350 1557 141 177 ± 24 30 ± 14 39.5 ± 0.6S3 17 3 1350 968 104 147 ± 19 20 ± 9 12.4 ± 0.3L3 18 3 1350 2288 165 206 ± 25 30 ± 14 27.2 ± 0.5S4 19 3 1350 134 104 125 ± 17 24 ± 9 12.3 ± 0.3L4 20 3 1350 1916 165 211 ± 28 31 ± 13 10.3 ± 0.3S1 21 3 1350 128 104 141 ± 20 28 ± 9 6.4 ± 0.2L1 22 3 1350 2306 165 198 ± 25 24 ± 11 7.4 ± 0.3S2 23 3 1350 115 104 141 ± 20 42 ± 11 5.0 ± 0.2L2 24 3 1350 1795 165 209 ± 28 33 ± 12 16.4 ± 0.4

Table 9: RBX 8

18

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1271 124 132 ± 19 36 ± 12 27.6 ± 0.5S24 2 1 1350 516 69 74 ± 10 21 ± 5 2.1 ± 0.2L13 3 1 1350 1646 123 119 ± 18 35 ± 11 19.2 ± 0.4S13 4 1 1350 282 65 71 ± 10 22 ± 5 3.0 ± 0.2L23 5 1 1350 1269 123 142 ± 20 41 ± 14 33.1 ± 0.6S23 6 1 1350 1654 68 81 ± 13 24 ± 7 12.7 ± 0.4L22 7 1 1350 1546 123 140 ± 19 40 ± 13 35.5 ± 0.6S22 8 1 1350 632 68 67 ± 10 23 ± 6 17.8 ± 0.4L21 9 2 1350 1355 141 178 ± 24 47 ± 15 22.2 ± 0.5S21 10 2 1350 262 88 97 ± 14 30 ± 11 3.6 ± 0.2L20 11 2 1350 243 141 167 ± 23 46 ± 14 19.0 ± 0.4S20 12 2 1350 285 88 85 ± 13 27 ± 6 2.3 ± 0.2L19 13 2 1350 2240 141 141 ± 20 20 ± 12 25.7 ± 0.5S19 14 2 1350 185 87 101 ± 16 18 ± 8 6.5 ± 0.3L18 15 2 1350 1206 141 139 ± 19 28 ± 12 24.8 ± 0.5S18 16 2 1350 1317 87 87 ± 13 18 ± 7 12.3 ± 0.3L17 17 3 1350 1925 166 192 ± 25 28 ± 14 12.8 ± 0.4S17 18 3 1350 612 104 121 ± 17 25 ± 13 47.6 ± 0.7L16 19 3 1350 2463 166 147 ± 21 29 ± 12 22.7 ± 0.5S16 20 3 1350 2211 104 95 ± 15 19 ± 7 6.7 ± 0.3L15 21 3 1350 1205 166 170 ± 25 40 ± 16 43.8 ± 0.7S15 22 3 1350 1387 104 154 ± 21 24 ± 11 28.1 ± 0.5L14 23 3 1350 943 166 164 ± 24 45 ± 12 18.5 ± 0.4S14 24 3 1350 2078 104 101 ± 16 22 ± 7 7.6 ± 0.3

Table 10: RBX 9

19

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1024 72 51 ± 9 19 ± 4 1.3 ± 0.1L11 2 1 1350 1959 126 94 ± 15 33 ± 10 14.9 ± 0.4S12 3 1 1350 393 72 56 ± 9 23 ± 5 3.4 ± 0.2L12 4 1 1350 2198 126 92 ± 15 29 ± 9 10.3 ± 0.3S9 5 1 1350 844 72 59 ± 10 25 ± 6 8.9 ± 0.3L9 6 1 1350 1363 126 103 ± 19 33 ± 11 15.9 ± 0.4

S10 7 1 1350 551 72 53 ± 9 21 ± 5 2.3 ± 0.2L10 8 1 1350 1351 126 100 ± 17 38 ± 13 20.2 ± 0.4S7 9 2 1350 571 90 70 ± 12 28 ± 10 2.5 ± 0.2L7 10 2 1350 961 145 135 ± 23 40 ± 14 15.9 ± 0.4S8 11 2 1350 1877 90 69 ± 12 25 ± 7 10.4 ± 0.3L8 12 2 1350 2382 145 96 ± 18 35 ± 12 12.1 ± 0.3S5 13 2 1350 355 90 71 ± 12 12 ± 7 3.2 ± 0.2L5 14 2 1350 1079 145 93 ± 16 18 ± 9 4.3 ± 0.2S6 15 2 1350 347 90 64 ± 11 17 ± 7 3.6 ± 0.2L6 16 2 1350 2079 145 95 ± 16 25 ± 13 42.1 ± 0.6S3 17 3 1350 170 106 88 ± 15 21 ± 9 7.2 ± 0.3L3 18 3 1350 1446 170 129 ± 21 30 ± 15 24.2 ± 0.5S4 19 3 1350 2084 106 63 ± 11 16 ± 6 3.9 ± 0.2L4 20 3 1350 1460 170 127 ± 23 29 ± 12 21.1 ± 0.5S1 21 3 1350 1352 105 90 ± 16 28 ± 10 14.3 ± 0.4L1 22 3 1350 2341 170 121 ± 20 24 ± 12 19.9 ± 0.4S2 23 3 1350 2062 105 61 ± 10 33 ± 7 3.0 ± 0.2L2 24 3 1350 1596 169 121 ± 21 32 ± 13 25.5 ± 0.5

Table 11: RBX 10

20

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1237 126 154 ± 20 36 ± 11 23.6 ± 0.5S24 2 1 1350 2086 72 74 ± 9 22 ± 5 5.0 ± 0.2L13 3 1 1350 1657 126 159 ± 20 42 ± 12 16.4 ± 0.4S13 4 1 1350 781 72 97 ± 13 26 ± 7 12.8 ± 0.4L23 5 1 1350 2307 126 158 ± 20 42 ± 13 34.2 ± 0.6S23 6 1 1350 1139 72 88 ± 13 23 ± 6 8.8 ± 0.3L22 7 1 1350 1080 126 171 ± 22 39 ± 12 30.9 ± 0.6S22 8 1 1350 867 72 103 ± 13 30 ± 9 30.0 ± 0.6L21 9 2 1350 2152 145 182 ± 22 41 ± 11 9.6 ± 0.3S21 10 2 1350 618 90 137 ± 18 36 ± 12 47.6 ± 0.7L20 11 2 1350 1432 145 205 ± 25 50 ± 15 37.2 ± 0.6S20 12 2 1350 803 90 113 ± 17 31 ± 9 15.0 ± 0.4L19 13 2 1350 1567 145 195 ± 25 29 ± 17 45.4 ± 0.7S19 14 2 1350 886 90 119 ± 16 20 ± 10 45.2 ± 0.7L18 15 2 1350 2369 145 169 ± 21 28 ± 11 26.5 ± 0.5S18 16 2 1350 289 90 136 ± 17 20 ± 8 5.2 ± 0.2L17 17 3 1350 1766 171 259 ± 32 34 ± 17 39.3 ± 0.6S17 18 3 1350 2189 106 139 ± 17 17 ± 8 4.8 ± 0.2L16 19 3 1350 1962 171 214 ± 28 33 ± 13 22.7 ± 0.5S16 20 3 1350 2077 106 121 ± 15 19 ± 6 5.5 ± 0.2L15 21 3 1350 1367 171 216 ± 29 39 ± 16 29.5 ± 0.5S15 22 3 1350 722 106 155 ± 20 24 ± 12 36.6 ± 0.6L14 23 3 1350 1501 171 194 ± 24 48 ± 14 41.6 ± 0.6S14 24 3 1350 2325 106 124 ± 17 22 ± 6 3.1 ± 0.2

Table 12: RBX 11

21

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 521 73 94 ± 12 25 ± 7 18.2 ± 0.4L11 2 1 1350 705 126 179 ± 22 47 ± 15 39.7 ± 0.6S12 3 1 1350 2196 73 74 ± 10 22 ± 5 5.1 ± 0.2L12 4 1 1350 1162 126 186 ± 23 44 ± 14 37.7 ± 0.6S9 5 1 1350 971 73 95 ± 12 27 ± 7 18.5 ± 0.4L9 6 1 1350 1831 126 177 ± 23 41 ± 13 31.4 ± 0.6

S10 7 1 1350 829 65 90 ± 12 24 ± 6 8.0 ± 0.3L10 8 1 1350 1434 126 157 ± 20 38 ± 11 27.9 ± 0.5S7 9 2 1350 293 90 128 ± 16 30 ± 8 4.6 ± 0.2L7 10 2 1350 460 146 185 ± 23 45 ± 14 37.0 ± 0.6S8 11 2 1350 1199 90 126 ± 15 33 ± 10 30.0 ± 0.6L8 12 2 1350 1105 146 168 ± 23 43 ± 14 35.7 ± 0.6S5 13 2 1350 1196 90 124 ± 16 16 ± 10 36.6 ± 0.6L5 14 2 1350 2179 145 160 ± 22 25 ± 12 18.0 ± 0.4S6 15 2 1350 1315 90 101 ± 13 20 ± 7 20.8 ± 0.5L6 16 2 1350 1397 145 226 ± 28 35 ± 17 46.8 ± 0.7S3 17 3 1350 68 106 154 ± 19 16 ± 7 4.2 ± 0.2L3 18 3 1350 2338 171 220 ± 26 28 ± 13 9.9 ± 0.3S4 19 3 1350 1340 106 118 ± 16 22 ± 9 19.3 ± 0.4L4 20 3 1350 1756 171 225 ± 28 33 ± 14 27.9 ± 0.5S1 21 3 1350 356 106 153 ± 19 27 ± 9 4.8 ± 0.2L1 22 3 1350 2215 171 216 ± 26 27 ± 12 10.6 ± 0.3S2 23 3 1350 254 106 134 ± 18 38 ± 8 4.3 ± 0.2L2 24 3 1350 1130 171 224 ± 31 37 ± 15 38.7 ± 0.6

Table 13: RBX 12

22

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1345 126 88 ± 17 33 ± 11 10.2 ± 0.3S24 2 1 1350 859 73 46 ± 9 19 ± 6 5.4 ± 0.2L13 3 1 1350 659 126 78 ± 15 32 ± 10 8.9 ± 0.3S13 4 1 1350 1506 73 42 ± 8 19 ± 5 2.2 ± 0.2L23 5 1 1350 1878 126 71 ± 13 29 ± 9 6.7 ± 0.3S23 6 1 1350 2115 64 31 ± 7 17 ± 4 1.3 ± 0.1L22 7 1 1350 1810 126 74 ± 14 29 ± 9 12.6 ± 0.3S22 8 1 1350 519 73 44 ± 9 22 ± 5 1.4 ± 0.1L21 9 2 1350 1464 146 82 ± 15 33 ± 11 13.6 ± 0.4S21 10 2 1350 1312 90 57 ± 10 24 ± 7 15.7 ± 0.4L20 11 2 1350 2250 146 85 ± 16 33 ± 11 12.5 ± 0.3S20 12 2 1350 2175 90 39 ± 8 19 ± 4 1.8 ± 0.1L19 13 2 1350 2344 146 81 ± 15 18 ± 11 10.6 ± 0.3S19 14 2 1350 623 90 52 ± 10 16 ± 7 18.2 ± 0.4L18 15 2 1350 1403 146 77 ± 14 23 ± 9 13.7 ± 0.4S18 16 2 1350 1198 90 63 ± 11 16 ± 8 13.9 ± 0.4L17 17 3 1350 1440 172 95 ± 18 25 ± 13 17.5 ± 0.4S17 18 3 1350 1781 106 74 ± 13 18 ± 9 11.8 ± 0.3L16 19 3 1350 2261 172 87 ± 17 26 ± 11 3.5 ± 0.2S16 20 3 1350 2135 106 55 ± 11 17 ± 6 4.3 ± 0.2L15 21 3 1350 1517 172 102 ± 20 32 ± 12 12.2 ± 0.3S15 22 3 1350 1823 106 75 ± 14 16 ± 7 9.5 ± 0.3L14 23 3 1350 77 171 96 ± 18 47 ± 12 2.3 ± 0.2S14 24 3 1350 2278 106 53 ± 11 20 ± 5 4.8 ± 0.2

Table 14: RBX 13

23

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 43 65 71 ± 11 22 ± 6 2.2 ± 0.2L11 2 1 1350 2302 126 120 ± 16 34 ± 10 16.9 ± 0.4S12 3 1 1350 540 73 74 ± 11 25 ± 8 2.5 ± 0.2L12 4 1 1350 767 126 132 ± 18 37 ± 13 32.3 ± 0.6S9 5 1 1350 303 73 73 ± 11 26 ± 6 2.8 ± 0.2L9 6 1 1350 1132 126 140 ± 21 38 ± 13 33.4 ± 0.6

S10 7 1 1350 566 73 73 ± 11 22 ± 5 3.2 ± 0.2L10 8 1 1350 279 126 132 ± 19 38 ± 10 4.1 ± 0.2S7 9 2 1350 278 91 95 ± 14 28 ± 8 3.0 ± 0.2L7 10 2 1350 1530 146 165 ± 23 43 ± 14 27.3 ± 0.5S8 11 2 1350 574 91 101 ± 14 30 ± 8 3.9 ± 0.2L8 12 2 1350 1799 146 148 ± 24 41 ± 13 11.6 ± 0.3S5 13 2 1350 2080 91 76 ± 11 9 ± 6 8.2 ± 0.3L5 14 2 1350 1603 146 140 ± 20 24 ± 12 29.4 ± 0.5S6 15 2 1350 1628 91 79 ± 11 21 ± 9 35.1 ± 0.6L6 16 2 1350 438 146 169 ± 25 31 ± 15 30.6 ± 0.6S3 17 3 1350 276 106 118 ± 17 17 ± 7 3.7 ± 0.2L3 18 3 1350 2216 172 186 ± 25 28 ± 13 11.8 ± 0.3S4 19 3 1350 133 106 103 ± 16 22 ± 9 3.6 ± 0.2L4 20 3 1350 1883 172 183 ± 27 34 ± 15 29.3 ± 0.5S1 21 3 1350 223 106 115 ± 17 27 ± 10 3.3 ± 0.2L1 22 3 1350 1955 172 172 ± 24 25 ± 11 15.6 ± 0.4S2 23 3 1350 903 106 97 ± 15 38 ± 9 23.4 ± 0.5L2 24 3 1350 1591 172 161 ± 24 34 ± 14 44.0 ± 0.7

Table 15: RBX 14

24

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 1050 126 279 ± 11 N/A N/AS24 2 1 1180 142 73 191 ± 8 N/A N/AL13 3 1 1180 245 126 299 ± 11 N/A N/AS13 4 1 1180 679 73 205 ± 8 N/A N/AL23 5 1 1180 907 127 297 ± 13 N/A N/AS23 6 1 1180 1240 73 158 ± 7 N/A N/AL22 7 1 1180 2245 127 256 ± 11 N/A N/AS22 8 1 1180 1322 73 151 ± 7 N/A N/AL21 9 2 1390 1893 147 458 ± 18 N/A N/AS21 10 2 1390 2303 91 237 ± 9 N/A N/AL20 11 2 1390 2237 147 410 ± 16 N/A N/AS20 12 2 1390 784 91 273 ± 12 N/A N/AL19 13 2 1390 1848 147 385 ± 16 N/A N/AS19 14 2 1390 2022 91 233 ± 10 N/A N/AL18 15 2 1390 1284 147 463 ± 18 N/A N/AS18 16 2 1390 346 91 291 ± 13 N/A N/AL17 17 3 1720 2347 173 587 ± 22 N/A N/AS17 18 3 1720 368 107 462 ± 16 N/A N/AL16 19 3 1720 1072 173 613 ± 34 N/A N/AS16 20 3 1720 1924 106 360 ± 14 N/A N/AL15 21 3 1720 1761 1736 635 ± 26 N/A N/AS15 22 3 1720 758 106 480 ± 18 N/A N/AL14 23 3 1720 213 173 674 ± 26 N/A N/AS14 24 3 1720 2391 106 340 ± 15 N/A N/A

Table 16: RBX 15

25

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 416 73 169 ± 7 N/A N/AL11 2 1 1180 814 127 270 ± 10 N/A N/AS12 3 1 1180 986 73 183 ± 7 N/A N/AL12 4 1 1180 1845 127 312 ± 12 N/A N/AS9 5 1 1180 912 73 178 ± 7 N/A N/AL9 6 1 1180 174 127 310 ± 13 N/A N/A

S10 7 1 1180 672 73 130 ± 5 N/A N/AL10 8 1 1180 93 127 303 ± 13 N/A N/AS7 9 2 1390 487 91 297 ± 11 N/A N/AL7 10 2 1390 230 147 494 ± 19 N/A N/AS8 11 2 1390 2055 91 234 ± 9 N/A N/AL8 12 2 1390 1104 147 450 ± 20 N/A N/AS5 13 2 1390 2095 91 226 ± 9 N/A N/AL5 14 2 1390 1129 147 438 ± 17 N/A N/AS6 15 2 1390 234 91 304 ± 12 N/A N/AL6 16 2 1390 1099 147 491 ± 19 N/A N/AS3 17 3 1720 2146 107 356 ± 14 N/A N/AL3 18 3 1720 2206 173 640 ± 23 N/A N/AS4 19 3 1720 756 107 477 ± 20 N/A N/AL4 20 3 1720 1620 173 652 ± 24 N/A N/AS1 21 3 1720 58 107 424 ± 19 N/A N/AL1 22 3 1720 2155 173 671 ± 25 N/A N/AS2 23 3 1720 274 107 445 ± 17 N/A N/AL2 24 3 1720 1931 173 636 ± 28 N/A N/A

Table 17: RBX 16

26

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1362 127 125 ± 20 37 ± 13 25.5 ± 0.5S24 2 1 1350 204 74 83 ± 12 26 ± 8 6.0 ± 0.2L13 3 1 1350 948 127 122 ± 19 38 ± 12 19.0 ± 0.4S13 4 1 1350 203 74 77 ± 12 25 ± 7 8.7 ± 0.3L23 5 1 1350 1983 127 122 ± 18 37 ± 12 26.4 ± 0.5S23 6 1 1350 497 74 71 ± 12 22 ± 6 2.2 ± 0.2L22 7 1 1350 79 127 128 ± 20 34 ± 11 4.2 ± 0.2S22 8 1 1350 598 73 72 ± 11 25 ± 7 15.9 ± 0.4L21 9 2 1350 1852 147 143 ± 21 43 ± 15 37.2 ± 0.6S21 10 2 1350 2068 91 78 ± 12 24 ± 6 2.9 ± 0.2L20 11 2 1350 1972 147 143 ± 20 41 ± 13 23.0 ± 0.5S20 12 2 1350 983 91 84 ± 15 27 ± 8 6.3 ± 0.2L19 13 2 1350 2253 147 124 ± 19 20 ± 10 11.3 ± 0.3S19 14 2 1350 528 91 85 ± 13 15 ± 7 8.9 ± 0.3L18 15 2 1350 79 147 128 ± 20 28 ± 11 12.4 ± 0.3S18 16 2 1350 598 91 76 ± 12 15 ± 6 4.4 ± 0.2L17 17 3 1350 1698 173 155 ± 23 28 ± 13 11.4 ± 0.3S17 18 3 1350 732 107 125 ± 18 25 ± 12 26.8 ± 0.5L16 19 3 1350 2343 173 124 ± 19 29 ± 12 25.1 ± 0.5S16 20 3 1350 1010 107 97 ± 14 21 ± 7 5.8 ± 0.2L15 21 3 1350 1801 173 130 ± 20 33 ± 13 24.0 ± 0.5S15 22 3 1350 2142 107 84 ± 12 14 ± 5 2.2 ± 0.2L14 23 3 1350 1539 173 143 ± 22 46 ± 12 22.2 ± 0.5S14 24 3 1350 1188 107 90 ± 15 22 ± 7 13.4 ± 0.4

Table 18: RBX 17

27

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 325 74 65 ± 10 22 ± 6 3.8 ± 0.2L11 2 1 1350 1102 127 106 ± 16 35 ± 12 31.6 ± 0.6S12 3 1 1350 563 74 66 ± 10 24 ± 6 5.1 ± 0.2L12 4 1 1350 1770 127 106 ± 17 35 ± 11 21.2 ± 0.5S9 5 1 1350 533 74 64 ± 10 23 ± 6 3.4 ± 0.2L9 6 1 1350 2446 127 107 ± 18 34 ± 12 22.6 ± 0.5

S10 7 1 1350 482 74 64 ± 10 24 ± 7 12.5 ± 0.3L10 8 1 1350 2061 127 85 ± 13 29 ± 8 6.4 ± 0.2S7 9 2 1350 1059 92 86 ± 13 25 ± 7 3.0 ± 0.2L7 10 2 1350 1084 147 139 ± 23 39 ± 13 21.7 ± 0.5S8 11 2 1350 525 91 79 ± 12 27 ± 7 6.1 ± 0.2L8 12 2 1350 1625 147 111 ± 20 36 ± 11 6.0 ± 0.2S5 13 2 1350 186 91 94 ± 16 16 ± 9 6.9 ± 0.3L5 14 2 1350 2207 147 105 ± 17 22 ± 11 21.3 ± 0.5S6 15 2 1350 36 91 78 ± 12 21 ± 7 4.6 ± 0.2L6 16 2 1350 1523 147 126 ± 20 29 ± 14 32.9 ± 0.6S3 17 3 1350 1189 107 100 ± 16 18 ± 9 20.8 ± 0.5L3 18 3 1350 1525 174 155 ± 23 31 ± 15 22.1 ± 0.5S4 19 3 1350 2170 107 64 ± 11 18 ± 6 10.8 ± 0.3L4 20 3 1350 1211 174 133 ± 21 27 ± 12 20.4 ± 0.4S1 21 3 1350 310 107 84 ± 14 25 ± 6 4.4 ± 0.2L1 22 3 1350 1796 174 159 ± 24 29 ± 13 21.6 ± 0.5S2 23 3 1350 1051 107 85 ± 14 36 ± 7 8.3 ± 0.3L2 24 3 1350 1794 174 153 ± 24 35 ± 13 19.3 ± 0.4

Table 19: RBX 18

28

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1257 130 107 ± 19 34 ± 11 20.0 ± 0.4S24 2 1 1350 308 76 61 ± 10 22 ± 6 5.0 ± 0.2L13 3 1 1350 64 130 110 ± 18 34 ± 10 3.1 ± 0.2S13 4 1 1350 1316 76 63 ± 10 22 ± 6 12.0 ± 0.3L23 5 1 1350 1595 130 108 ± 18 39 ± 13 26.2 ± 0.5S23 6 1 1350 385 76 35 ± 7 15 ± 3 1.2 ± 0.1L22 7 1 1350 1908 130 102 ± 16 31 ± 9 7.3 ± 0.3S22 8 1 1350 1509 76 55 ± 9 22 ± 7 19.4 ± 0.4L21 9 2 1350 830 150 131 ± 20 44 ± 15 29.6 ± 0.5S21 10 2 1350 277 94 84 ± 14 27 ± 7 3.2 ± 0.2L20 11 2 1350 963 150 154 ± 23 43 ± 14 27.1 ± 0.5S20 12 2 1350 1019 94 67 ± 12 24 ± 6 4.9 ± 0.2L19 13 2 1350 999 150 132 ± 21 24 ± 13 29.9 ± 0.6S19 14 2 1350 680 94 81 ± 13 17 ± 8 18.7 ± 0.4L18 15 2 1350 1428 150 128 ± 20 32 ± 15 32.8 ± 0.6S18 16 2 1350 2200 94 70 ± 11 16 ± 7 17.0 ± 0.4L17 17 3 1350 1800 180 150 ± 22 28 ± 13 15.5 ± 0.4S17 18 3 1350 1610 109 106 ± 15 18 ± 8 5.5 ± 0.2L16 19 3 1350 1445 180 152 ± 25 34 ± 16 33.9 ± 0.6S16 20 3 1350 731 109 94 ± 14 22 ± 9 20.1 ± 0.4L15 21 3 1350 1568 180 169 ± 26 39 ± 16 31.4 ± 0.6S15 22 3 1350 1282 109 118 ± 17 23 ± 11 30.2 ± 0.6L14 23 3 1350 1499 180 151 ± 23 47 ± 13 24.0 ± 0.5S14 24 3 1350 261 109 95 ± 16 23 ± 6 2.9 ± 0.2

Table 20: RBX 19

29

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 501 77 60 ± 10 22 ± 6 8.7 ± 0.3L11 2 1 1350 949 131 113 ± 18 37 ± 13 24.2 ± 0.5S12 3 1 1350 573 77 55 ± 9 21 ± 5 2.0 ± 0.1L12 4 1 1350 1912 131 106 ± 18 35 ± 11 12.9 ± 0.4S9 5 1 1350 661 77 63 ± 11 26 ± 8 21.0 ± 0.5L9 6 1 1350 106 131 110 ± 21 38 ± 13 3.4 ± 0.2

S10 7 1 1350 538 76 62 ± 11 25 ± 6 2.5 ± 0.2L10 8 1 1350 2301 130 87 ± 14 32 ± 10 16.6 ± 0.4S7 9 2 1350 1934 94 65 ± 11 25 ± 6 2.7 ± 0.2L7 10 2 1350 1505 150 114 ± 19 35 ± 12 18.1 ± 0.4S8 11 2 1350 2311 118 90 ± 15 32 ± 10 20.5 ± 0.4L8 12 2 1350 1964 150 108 ± 20 39 ± 13 15.4 ± 0.4S5 13 2 1350 2130 94 61 ± 10 9 ± 5 5.1 ± 0.2L5 14 2 1350 2448 150 104 ± 18 21 ± 10 13.9 ± 0.4S6 15 2 1350 716 94 64 ± 11 19 ± 8 15.7 ± 0.4L6 16 2 1350 2427 150 110 ± 19 27 ± 11 17.2 ± 0.4S3 17 3 1350 255 110 79 ± 14 17 ± 6 2.2 ± 0.2L3 18 3 1350 1083 180 137 ± 22 31 ± 14 24.4 ± 0.5S4 19 3 1350 118 110 81 ± 14 22 ± 8 3.8 ± 0.2L4 20 3 1350 2124 180 124 ± 21 29 ± 13 20.5 ± 0.4S1 21 3 1350 1140 110 80 ± 14 26 ± 9 22.6 ± 0.5L1 22 3 1350 1454 180 138 ± 22 27 ± 13 22.7 ± 0.5S2 23 3 1350 108 110 74 ± 13 37 ± 7 2.9 ± 0.2L2 24 3 1350 2233 180 112 ± 20 29 ± 10 12.3 ± 0.3

Table 21: RBX 20

30

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 2292 131 104 ± 17 34 ± 11 17.4 ± 0.4S24 2 1 1350 660 77 66 ± 11 24 ± 7 13.8 ± 0.4L13 3 1 1350 895 131 112 ± 19 38 ± 13 22.5 ± 0.5S13 4 1 1350 561 77 52 ± 9 19 ± 5 2.7 ± 0.2L23 5 1 1350 2045 131 93 ± 16 33 ± 10 10.2 ± 0.3S23 6 1 1350 315 77 60 ± 11 20 ± 5 2.1 ± 0.1L22 7 1 1350 1174 131 104 ± 17 33 ± 10 14.7 ± 0.4S22 8 1 1350 2072 77 45 ± 8 20 ± 6 3.9 ± 0.2L21 9 2 1350 1797 151 121 ± 20 42 ± 13 12.0 ± 0.3S21 10 2 1350 1062 94 73 ± 12 24 ± 6 1.9 ± 0.1L20 11 2 1350 2275 151 106 ± 18 38 ± 12 13.8 ± 0.4S20 12 2 1350 455 94 66 ± 12 27 ± 9 12.9 ± 0.4L19 13 2 1350 1094 151 117 ± 20 22 ± 12 11.7 ± 0.3S19 14 2 1350 1277 94 66 ± 12 15 ± 7 12.2 ± 0.3L18 15 2 1350 2044 151 98 ± 16 25 ± 10 12.0 ± 0.3S18 16 2 1350 1042 94 70 ± 12 16 ± 6 4.3 ± 0.2L17 17 3 1350 1515 181 137 ± 21 29 ± 15 27.0 ± 0.5S17 18 3 1350 976 118 110 ± 17 22 ± 10 20.6 ± 0.4L16 19 3 1350 69 181 130 ± 22 27 ± 13 3.5 ± 0.2S16 20 3 1350 2314 110 76 ± 13 19 ± 7 7.4 ± 0.3L15 21 3 1350 66 180 142 ± 24 36 ± 13 3.5 ± 0.2S15 22 3 1350 2337 110 84 ± 14 14 ± 7 2.6 ± 0.2L14 23 3 1350 724 180 132 ± 23 52 ± 15 30.1 ± 0.6S14 24 3 1350 1588 110 86 ± 16 23 ± 8 19.1 ± 0.4

Table 22: RBX 21

31

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1138 77 82 ± 12 26 ± 9 33.5 ± 0.6L11 2 1 1350 1791 131 160 ± 21 42 ± 13 27.9 ± 0.5S12 3 1 1350 421 77 88 ± 13 31 ± 11 42.3 ± 0.6L12 4 1 1350 1254 131 151 ± 21 40 ± 13 29.4 ± 0.5S9 5 1 1350 513 77 89 ± 12 29 ± 7 3.5 ± 0.2L9 6 1 1350 1186 131 154 ± 23 39 ± 13 28.2 ± 0.5

S10 7 1 1350 804 77 98 ± 14 28 ± 9 11.2 ± 0.3L10 8 1 1350 1472 131 147 ± 21 42 ± 13 26.3 ± 0.5S7 9 2 1350 2069 94 92 ± 13 27 ± 6 4.5 ± 0.2L7 10 2 1350 1669 151 166 ± 23 42 ± 13 26.3 ± 0.5S8 11 2 1350 2313 94 95 ± 13 28 ± 8 15.5 ± 0.4L8 12 2 1350 640 151 100 ± 16 29 ± 9 16.5 ± 0.4S5 13 2 1350 878 94 112 ± 16 18 ± 11 40.9 ± 0.6L5 14 2 1350 1173 151 171 ± 23 29 ± 14 34.0 ± 0.6S6 15 2 1350 813 94 103 ± 14 23 ± 10 28.7 ± 0.5L6 16 2 1350 991 151 199 ± 27 35 ± 17 40.6 ± 0.6S3 17 3 1350 614 110 128 ± 17 25 ± 14 50.5 ± 0.7L3 18 3 1350 2243 181 199 ± 25 32 ± 16 35.0 ± 0.6S4 19 3 1350 2128 110 104 ± 15 19 ± 7 6.6 ± 0.3L4 20 3 1350 697 181 127 ± 18 27 ± 12 34.1 ± 0.6S1 21 3 1350 1030 110 120 ± 17 25 ± 8 5.0 ± 0.2L1 22 3 1350 1118 181 232 ± 30 37 ± 17 38.1 ± 0.6S2 23 3 1350 2145 110 91 ± 13 34 ± 5 3.9 ± 0.2L2 24 3 1350 1619 181 182 ± 26 32 ± 12 12.6 ± 0.4

Table 23: RBX 22

32

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 959 131 150 ± 22 40 ± 13 27.2 ± 0.5S24 2 1 1350 208 77 96 ± 14 28 ± 8 7.5 ± 0.3L13 3 1 1350 1519 131 148 ± 22 41 ± 14 25.1 ± 0.5S13 4 1 1350 897 78 93 ± 14 28 ± 9 20.3 ± 0.4L23 5 1 1350 1348 131 144 ± 21 42 ± 13 25.8 ± 0.5S23 6 1 1350 329 78 67 ± 11 21 ± 5 3.1 ± 0.2L22 7 1 1350 233 131 151 ± 21 38 ± 14 4.5 ± 0.2S22 8 1 1350 1002 78 64 ± 9 22 ± 4 1.7 ± 0.1L21 9 2 1350 1253 151 148 ± 21 44 ± 15 37.7 ± 0.6S21 10 2 1350 1089 95 99 ± 14 28 ± 9 17.3 ± 0.4L20 11 2 1350 1622 151 165 ± 24 43 ± 14 17.6 ± 0.4S20 12 2 1350 600 94 89 ± 15 30 ± 10 28.0 ± 0.5L19 13 2 1350 1091 151 150 ± 22 24 ± 14 30.7 ± 0.6S19 14 2 1350 1945 94 81 ± 12 13 ± 5 6.0 ± 0.2L18 15 2 1350 1724 151 150 ± 22 30 ± 13 25.2 ± 0.5S18 16 2 1350 1192 94 111 ± 16 22 ± 11 35.3 ± 0.6L17 17 3 1350 1599 182 192 ± 27 30 ± 14 22.3 ± 0.5S17 18 3 1350 714 110 127 ± 17 23 ± 11 24.5 ± 0.5L16 19 3 1350 1910 182 192 ± 27 32 ± 14 14.1 ± 0.4S16 20 3 1350 2118 110 100 ± 15 19 ± 8 10.6 ± 0.3L15 21 3 1350 1763 182 187 ± 28 38 ± 15 17.2 ± 0.4S15 22 3 1350 615 110 114 ± 16 22 ± 12 49.3 ± 0.7L14 23 3 1350 1866 182 177 ± 26 43 ± 12 8.9 ± 0.3S14 24 3 1350 2051 110 89 ± 14 20 ± 6 10.3 ± 0.3

Table 24: RBX 23

33

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 644 78 74 ± 11 23 ± 7 18.2 ± 0.4L11 2 1 1350 2293 121 111 ± 16 33 ± 9 14.9 ± 0.4S12 3 1 1350 1968 78 77 ± 11 25 ± 6 8.9 ± 0.3L12 4 1 1350 1000 131 157 ± 24 43 ± 14 26.5 ± 0.5S9 5 1 1350 609 78 90 ± 13 30 ± 10 30.4 ± 0.6L9 6 1 1350 2129 131 131 ± 20 36 ± 12 25.3 ± 0.5

S10 7 1 1350 1136 78 82 ± 12 26 ± 8 28.2 ± 0.5L10 8 1 1350 2013 131 113 ± 16 33 ± 9 12.6 ± 0.3S7 9 2 1350 228 118 138 ± 19 40 ± 13 4.6 ± 0.2L7 10 2 1350 1538 151 154 ± 21 41 ± 14 30.3 ± 0.6S8 11 2 1350 161 95 115 ± 17 35 ± 9 9.2 ± 0.3L8 12 2 1350 2066 151 134 ± 22 39 ± 13 5.7 ± 0.2S5 13 2 1350 596 95 104 ± 15 15 ± 10 28.9 ± 0.5L5 14 2 1350 1450 151 144 ± 21 24 ± 12 30.2 ± 0.6S6 15 2 1350 601 95 99 ± 14 23 ± 11 40.8 ± 0.6L6 16 2 1350 1790 151 176 ± 25 27 ± 13 12.1 ± 0.3S3 17 3 1350 2064 110 92 ± 13 15 ± 7 4.4 ± 0.2L3 18 3 1350 1786 182 192 ± 26 30 ± 14 18.3 ± 0.4S4 19 3 1350 1248 110 94 ± 14 21 ± 9 28.2 ± 0.5L4 20 3 1350 1459 182 182 ± 26 35 ± 15 34.3 ± 0.6S1 21 3 1350 260 110 126 ± 19 26 ± 9 3.5 ± 0.2L1 22 3 1350 2120 182 196 ± 27 28 ± 13 16.5 ± 0.4S2 23 3 1350 1302 110 112 ± 17 40 ± 10 30.5 ± 0.6L2 24 3 1350 1836 182 183 ± 28 33 ± 13 21.5 ± 0.5

Table 25: RBX 24

34

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1520 132 98 ± 17 32 ± 11 13.5 ± 0.4S24 2 1 1350 1375 78 62 ± 10 26 ± 9 30.5 ± 0.6L13 3 1 1350 1410 132 98 ± 17 35 ± 12 22.5 ± 0.5S13 4 1 1350 2322 78 48 ± 8 20 ± 4 2.5 ± 0.2L23 5 1 1350 1635 132 95 ± 16 40 ± 15 44.8 ± 0.7S23 6 1 1350 1973 78 60 ± 12 22 ± 6 5.8 ± 0.2L22 7 1 1350 267 132 105 ± 18 32 ± 11 3.0 ± 0.2S22 8 1 1350 593 78 59 ± 10 24 ± 8 16.6 ± 0.4L21 9 2 1350 1249 152 109 ± 18 38 ± 14 24.4 ± 0.5S21 10 2 1350 650 95 75 ± 13 28 ± 10 27.5 ± 0.5L20 11 2 1350 2416 152 103 ± 18 38 ± 13 23.8 ± 0.5S20 12 2 1350 985 95 70 ± 13 26 ± 8 11.8 ± 0.3L19 13 2 1350 1580 152 110 ± 19 23 ± 14 24.2 ± 0.5S19 14 2 1350 1809 95 68 ± 12 16 ± 7 14.1 ± 0.4L18 15 2 1350 1152 152 96 ± 16 28 ± 13 28.9 ± 0.5S18 16 2 1350 2042 95 59 ± 10 14 ± 5 7.2 ± 0.3L17 17 3 1350 1715 183 119 ± 20 23 ± 13 6.8 ± 0.3S17 18 3 1350 1418 111 94 ± 15 21 ± 10 20.7 ± 0.5L16 19 3 1350 1675 183 118 ± 22 29 ± 11 10.5 ± 0.3S16 20 3 1350 227 111 84 ± 15 21 ± 8 2.5 ± 0.2L15 21 3 1350 1887 182 139 ± 24 38 ± 15 12.7 ± 0.4S15 22 3 1350 2246 110 75 ± 12 14 ± 7 5.6 ± 0.2L14 23 3 1350 1583 182 130 ± 22 48 ± 13 24.9 ± 0.5S14 24 3 1350 1106 110 79 ± 14 22 ± 7 10.2 ± 0.3

Table 26: RBX 25

35

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 2154 79 55 ± 10 19 ± 5 1.6 ± 0.1L11 2 1 1350 2330 132 92 ± 15 32 ± 10 10.8 ± 0.3S12 3 1 1350 1311 79 62 ± 10 25 ± 7 17.6 ± 0.4L12 4 1 1350 1814 132 109 ± 18 34 ± 12 16.1 ± 0.4S9 5 1 1350 423 78 55 ± 10 25 ± 8 22.9 ± 0.5L9 6 1 1350 1097 132 108 ± 20 36 ± 12 17.5 ± 0.4

S10 7 1 1350 2023 78 52 ± 9 19 ± 4 3.1 ± 0.2L10 8 1 1350 1789 132 108 ± 18 38 ± 13 20.9 ± 0.5S7 9 2 1350 1020 95 68 ± 11 25 ± 6 2.1 ± 0.1L7 10 2 1350 2329 152 110 ± 19 35 ± 12 5.7 ± 0.2S8 11 2 1350 1337 95 74 ± 13 28 ± 9 17.6 ± 0.4L8 12 2 1350 698 152 103 ± 20 41 ± 15 24.7 ± 0.5S5 13 2 1350 728 118 89 ± 16 19 ± 12 26.8 ± 0.5L5 14 2 1350 1663 152 111 ± 18 21 ± 10 12.0 ± 0.3S6 15 2 1350 180 95 72 ± 13 22 ± 9 15.6 ± 0.4L6 16 2 1350 1294 152 119 ± 20 29 ± 15 30.4 ± 0.6S3 17 3 1350 2197 111 75 ± 12 16 ± 8 18.8 ± 0.4L3 18 3 1350 1784 183 144 ± 23 28 ± 13 13.3 ± 0.4S4 19 3 1350 1035 111 75 ± 13 20 ± 8 2.7 ± 0.2L4 20 3 1350 2398 183 128 ± 22 33 ± 14 23.1 ± 0.5S1 21 3 1350 663 111 76 ± 14 25 ± 9 17.4 ± 0.4L1 22 3 1350 2217 183 139 ± 23 23 ± 12 7.5 ± 0.3S2 23 3 1350 2280 118 69 ± 12 35 ± 7 10.4 ± 0.3L2 24 3 1350 2405 183 114 ± 23 31 ± 12 14.2 ± 0.4

Table 27: RBX 26

36

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1953 132 102 ± 18 34 ± 11 16.4 ± 0.4S24 2 1 1350 327 79 57 ± 9 20 ± 4 2.1 ± 0.1L13 3 1 1350 1547 132 99 ± 17 36 ± 12 23.3 ± 0.5S13 4 1 1350 984 79 60 ± 10 23 ± 6 9.5 ± 0.3L23 5 1 1350 1469 132 89 ± 16 34 ± 11 20.1 ± 0.4S23 6 1 1350 888 79 66 ± 12 24 ± 8 17.4 ± 0.4L22 7 1 1350 2323 132 98 ± 16 35 ± 12 27.6 ± 0.5S22 8 1 1350 531 79 56 ± 10 22 ± 5 6.1 ± 0.2L21 9 2 1350 1168 153 119 ± 19 40 ± 13 24.2 ± 0.5S21 10 2 1350 2260 118 91 ± 15 30 ± 9 8.9 ± 0.3L20 11 2 1350 2223 153 108 ± 17 37 ± 12 16.5 ± 0.4S20 12 2 1350 1319 95 70 ± 13 29 ± 10 18.4 ± 0.4L19 13 2 1350 2354 152 108 ± 19 17 ± 11 7.8 ± 0.3S19 14 2 1350 570 95 67 ± 11 15 ± 7 4.8 ± 0.2L18 15 2 1350 741 152 118 ± 20 36 ± 16 32.6 ± 0.6S18 16 2 1350 816 95 91 ± 15 22 ± 10 26.0 ± 0.5L17 17 3 1350 2140 184 140 ± 22 29 ± 14 17.4 ± 0.4S17 18 3 1350 826 111 92 ± 15 19 ± 10 16.6 ± 0.4L16 19 3 1350 2116 184 126 ± 21 31 ± 14 24.2 ± 0.5S16 20 3 1350 454 111 82 ± 14 22 ± 9 20.6 ± 0.4L15 21 3 1350 2247 184 122 ± 21 34 ± 13 14.5 ± 0.4S15 22 3 1350 225 111 100 ± 16 20 ± 9 3.1 ± 0.2L14 23 3 1350 1110 183 131 ± 22 44 ± 12 7.3 ± 0.3S14 24 3 1350 800 111 78 ± 14 23 ± 7 9.8 ± 0.3

Table 28: RBX 27

37

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 288 81 65 ± 11 24 ± 7 2.5 ± 0.2L11 2 1 1350 1339 134 101 ± 16 36 ± 13 25.6 ± 0.5S12 3 1 1350 1064 81 64 ± 11 25 ± 7 3.9 ± 0.2L12 4 1 1350 478 134 62 ± 10 22 ± 6 2.6 ± 0.2S9 5 1 1350 1210 81 67 ± 12 26 ± 8 14.2 ± 0.4L9 6 1 1350 710 134 121 ± 22 40 ± 13 14.3 ± 0.4

S10 7 1 1350 1028 81 64 ± 10 22 ± 6 1.7 ± 0.1L10 8 1 1350 1611 134 99 ± 16 36 ± 12 19.0 ± 0.4S7 9 2 1350 2163 98 66 ± 11 24 ± 6 4.6 ± 0.2L7 10 2 1350 1850 156 117 ± 19 39 ± 14 23.9 ± 0.5S8 11 2 1350 18 98 79 ± 14 29 ± 8 2.8 ± 0.2L8 12 2 1350 1073 155 110 ± 20 37 ± 12 12.0 ± 0.3S5 13 2 1350 664 98 77 ± 14 13 ± 8 12.6 ± 0.4L5 14 2 1350 1070 121 85 ± 14 18 ± 7 2.5 ± 0.2S6 15 2 1350 2162 98 62 ± 10 17 ± 6 10.9 ± 0.3L6 16 2 1350 2241 155 111 ± 18 25 ± 11 19.1 ± 0.4S3 17 3 1350 1946 115 86 ± 14 17 ± 8 11.0 ± 0.3L3 18 3 1350 1113 193 156 ± 25 37 ± 18 37.2 ± 0.6S4 19 3 1350 65 115 85 ± 14 22 ± 10 2.8 ± 0.2L4 20 3 1350 1835 193 141 ± 23 32 ± 13 15.7 ± 0.4S1 21 3 1350 2006 114 78 ± 14 24 ± 8 13.2 ± 0.4L1 22 3 1350 1685 192 152 ± 25 27 ± 12 16.0 ± 0.4S2 23 3 1350 2356 114 72 ± 13 37 ± 8 17.4 ± 0.4L2 24 3 1350 1494 192 132 ± 23 31 ± 12 18.1 ± 0.4

Table 29: RBX 28

38

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 401 135 79 ± 16 33 ± 14 3.3 ± 0.2S24 2 1 1350 541 81 41 ± 8 22 ± 7 2.0 ± 0.1L13 3 1 1350 1960 135 68 ± 14 31 ± 10 5.2 ± 0.2S13 4 1 1350 209 81 50 ± 11 23 ± 6 4.7 ± 0.2L23 5 1 1350 1586 135 82 ± 16 36 ± 13 22.2 ± 0.5S23 6 1 1350 473 81 48 ± 11 22 ± 6 2.2 ± 0.2L22 7 1 1350 1441 135 70 ± 14 30 ± 11 15.1 ± 0.4S22 8 1 1350 1989 81 34 ± 7 18 ± 5 5.6 ± 0.2L21 9 2 1350 2379 156 91 ± 18 39 ± 12 7.3 ± 0.3S21 10 2 1350 956 98 58 ± 12 25 ± 9 14.1 ± 0.4L20 11 2 1350 250 156 92 ± 18 37 ± 13 2.8 ± 0.2S20 12 2 1350 251 98 49 ± 11 23 ± 7 1.5 ± 0.1L19 13 2 1350 2351 156 76 ± 15 18 ± 10 5.0 ± 0.2S19 14 2 1350 1943 119 57 ± 12 17 ± 7 5.8 ± 0.2L18 15 2 1350 1863 156 70 ± 14 25 ± 10 7.5 ± 0.3S18 16 2 1350 1902 98 51 ± 10 14 ± 6 2.4 ± 0.2L17 17 3 1350 1706 194 106 ± 21 27 ± 14 10.8 ± 0.3S17 18 3 1350 1422 115 66 ± 13 21 ± 10 19.4 ± 0.4L16 19 3 1350 1555 194 92 ± 19 33 ± 14 22.0 ± 0.5S16 20 3 1350 1310 115 54 ± 12 20 ± 7 8.8 ± 0.3L15 21 3 1350 1576 193 101 ± 22 40 ± 16 21.7 ± 0.5S15 22 3 1350 91 115 68 ± 14 16 ± 5 2.0 ± 0.1L14 23 3 1350 1504 193 94 ± 19 49 ± 13 18.8 ± 0.4S14 24 3 1350 2039 119 51 ± 11 21 ± 5 4.4 ± 0.2

Table 30: RBX 29

39

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1655 82 61 ± 11 23 ± 6 11.8 ± 0.3L11 2 1 1350 1200 135 98 ± 16 35 ± 12 33.8 ± 0.6S12 3 1 1350 361 82 65 ± 11 25 ± 6 5.0 ± 0.2L12 4 1 1350 1327 135 109 ± 18 36 ± 13 32.3 ± 0.6S9 5 1 1350 474 82 66 ± 11 24 ± 5 2.4 ± 0.2L9 6 1 1350 707 135 122 ± 22 41 ± 15 27.5 ± 0.5

S10 7 1 1350 603 81 66 ± 11 25 ± 8 22.6 ± 0.5L10 8 1 1350 1485 135 108 ± 18 38 ± 13 23.7 ± 0.5S7 9 2 1350 2224 99 72 ± 12 26 ± 7 9.0 ± 0.3L7 10 2 1350 1442 156 124 ± 21 39 ± 14 24.9 ± 0.5S8 11 2 1350 1868 99 73 ± 13 27 ± 8 12.5 ± 0.3L8 12 2 1350 1305 156 121 ± 22 40 ± 14 22.7 ± 0.5S5 13 2 1350 162 98 85 ± 15 17 ± 8 6.4 ± 0.2L5 14 2 1350 1263 156 105 ± 18 21 ± 10 21.0 ± 0.5S6 15 2 1350 1630 98 69 ± 11 21 ± 10 37.1 ± 0.6L6 16 2 1350 379 156 71 ± 12 17 ± 6 3.6 ± 0.2S3 17 3 1350 975 115 99 ± 15 20 ± 11 26.1 ± 0.5L3 18 3 1350 2139 195 159 ± 24 32 ± 16 18.4 ± 0.4S4 19 3 1350 1927 115 83 ± 14 19 ± 7 3.4 ± 0.2L4 20 3 1350 2186 194 137 ± 23 30 ± 12 15.2 ± 0.4S1 21 3 1350 2063 115 78 ± 13 22 ± 7 3.1 ± 0.2L1 22 3 1350 1594 194 154 ± 25 28 ± 14 21.6 ± 0.5S2 23 3 1350 1341 115 93 ± 16 40 ± 10 20.8 ± 0.5L2 24 3 1350 1679 194 149 ± 27 30 ± 13 12.1 ± 0.3

Table 31: RBX 30

40

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 2308 135 113 ± 18 35 ± 10 5.2 ± 0.2S24 2 1 1350 580 82 70 ± 11 27 ± 8 2.8 ± 0.2L13 3 1 1350 802 135 132 ± 20 41 ± 13 17.6 ± 0.4S13 4 1 1350 954 82 88 ± 15 26 ± 8 11.2 ± 0.3L23 5 1 1350 1824 135 127 ± 20 40 ± 12 17.6 ± 0.4S23 6 1 1350 1861 82 71 ± 12 23 ± 6 4.0 ± 0.2L22 7 1 1350 637 135 124 ± 19 40 ± 14 35.4 ± 0.6S22 8 1 1350 2003 82 67 ± 11 24 ± 7 9.1 ± 0.3L21 9 2 1350 744 157 167 ± 25 52 ± 17 37.0 ± 0.6S21 10 2 1350 2127 99 88 ± 14 26 ± 7 4.5 ± 0.2L20 11 2 1350 59 157 138 ± 21 41 ± 14 4.1 ± 0.2S20 12 2 1350 2169 99 73 ± 13 27 ± 9 1.9 ± 0.1L19 13 2 1350 1437 156 148 ± 23 26 ± 15 29.0 ± 0.5S19 14 2 1350 1276 98 95 ± 15 19 ± 9 21.4 ± 0.5L18 15 2 1350 1386 156 143 ± 22 34 ± 15 29.6 ± 0.5S18 16 2 1350 1320 98 77 ± 12 18 ± 7 19.3 ± 0.4L17 17 3 1350 1492 196 170 ± 25 31 ± 16 32.3 ± 0.6S17 18 3 1350 892 115 114 ± 17 24 ± 13 42.0 ± 0.6L16 19 3 1350 1406 196 174 ± 27 37 ± 16 30.8 ± 0.6S16 20 3 1350 933 115 110 ± 17 26 ± 12 33.1 ± 0.6L15 21 3 1350 2239 195 153 ± 23 36 ± 13 17.7 ± 0.4S15 22 3 1350 469 115 117 ± 17 20 ± 10 2.9 ± 0.2L14 23 3 1350 2585 195 154 ± 25 52 ± 14 24.4 ± 0.5S14 24 3 1350 2467 115 100 ± 16 23 ± 8 13.9 ± 0.4

Table 32: RBX 31

41

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 669 82 74 ± 12 25 ± 8 14.7 ± 0.4L11 2 1 1350 1215 136 123 ± 18 39 ± 13 28.4 ± 0.5S12 3 1 1350 42 82 72 ± 12 27 ± 8 2.2 ± 0.2L12 4 1 1350 1958 136 122 ± 19 34 ± 11 13.2 ± 0.4S9 5 1 1350 550 82 70 ± 11 25 ± 7 13.0 ± 0.4L9 6 1 1350 74 136 132 ± 22 37 ± 12 2.9 ± 0.2

S10 7 1 1350 1328 82 77 ± 12 27 ± 9 22.7 ± 0.5L10 8 1 1350 71 136 127 ± 21 40 ± 12 3.6 ± 0.2S7 9 2 1350 2319 99 97 ± 16 31 ± 10 10.5 ± 0.3L7 10 2 1350 2208 157 134 ± 20 39 ± 12 13.8 ± 0.4S8 11 2 1350 847 99 94 ± 14 31 ± 10 16.8 ± 0.4L8 12 2 1350 1077 157 142 ± 23 41 ± 14 20.2 ± 0.4S5 13 2 1350 1137 99 91 ± 14 15 ± 9 26.5 ± 0.5L5 14 2 1350 1491 157 136 ± 20 27 ± 13 28.5 ± 0.5S6 15 2 1350 1304 99 82 ± 13 22 ± 9 20.0 ± 0.4L6 16 2 1350 1757 157 165 ± 25 34 ± 16 31.7 ± 0.6S3 17 3 1350 1816 115 116 ± 18 22 ± 12 27.7 ± 0.5L3 18 3 1350 1701 198 185 ± 27 34 ± 16 25.0 ± 0.5S4 19 3 1350 163 115 98 ± 16 24 ± 10 11.7 ± 0.3L4 20 3 1350 78 197 170 ± 27 28 ± 15 6.7 ± 0.3S1 21 3 1350 1477 115 92 ± 14 25 ± 8 15.8 ± 0.4L1 22 3 1350 1922 197 190 ± 27 33 ± 15 19.5 ± 0.4S2 23 3 1350 266 115 102 ± 16 40 ± 11 2.8 ± 0.2L2 24 3 1350 2000 196 152 ± 25 35 ± 13 18.5 ± 0.4

Table 33: RBX 32

42

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 2349 136 141 ± 21 38 ± 12 25.6 ± 0.5S24 2 1 1350 885 83 87 ± 12 27 ± 9 27.9 ± 0.5L13 3 1 1350 1597 136 151 ± 21 43 ± 14 32.7 ± 0.6S13 4 1 1350 701 83 108 ± 15 33 ± 11 37.0 ± 0.6L23 5 1 1350 936 136 163 ± 24 47 ± 16 38.7 ± 0.6S23 6 1 1350 1086 82 96 ± 15 25 ± 6 3.8 ± 0.2L22 7 1 1350 2327 136 134 ± 18 36 ± 10 15.1 ± 0.4S22 8 1 1350 211 82 96 ± 15 29 ± 8 5.6 ± 0.2L21 9 2 1350 1307 158 175 ± 24 49 ± 16 32.1 ± 0.6S21 10 2 1350 958 99 118 ± 16 32 ± 10 21.4 ± 0.5L20 11 2 1350 1670 157 167 ± 23 45 ± 14 21.2 ± 0.5S20 12 2 1350 861 99 108 ± 17 31 ± 10 19.7 ± 0.4L19 13 2 1350 1834 157 164 ± 22 26 ± 14 27.5 ± 0.5S19 14 2 1350 124 99 96 ± 15 18 ± 7 5.6 ± 0.2L18 15 2 1350 1308 157 160 ± 23 33 ± 13 24.4 ± 0.5S18 16 2 1350 2005 99 98 ± 14 17 ± 7 6.0 ± 0.2L17 17 3 1350 1702 199 201 ± 28 33 ± 17 32.8 ± 0.6S17 18 3 1350 1488 115 132 ± 17 21 ± 10 20.3 ± 0.4L16 19 3 1350 1923 198 193 ± 27 32 ± 15 14.6 ± 0.4S16 20 3 1350 1346 115 138 ± 20 27 ± 12 24.6 ± 0.5L15 21 3 1350 1885 198 209 ± 30 41 ± 16 26.3 ± 0.5S15 22 3 1350 2324 119 120 ± 17 18 ± 8 7.1 ± 0.3L14 23 3 1350 1157 198 195 ± 28 53 ± 15 28.8 ± 0.5S14 24 3 1350 1602 115 114 ± 17 25 ± 8 23.5 ± 0.5

Table 34: RBX 33

43

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 555 83 82 ± 12 24 ± 6 5.2 ± 0.2L11 2 1 1350 458 136 134 ± 19 42 ± 13 35.5 ± 0.6S12 3 1 1350 980 83 84 ± 13 28 ± 8 19.0 ± 0.4L12 4 1 1350 1551 136 129 ± 19 41 ± 14 40.7 ± 0.6S9 5 1 1350 1239 83 86 ± 13 28 ± 7 14.2 ± 0.4L9 6 1 1350 1905 136 150 ± 23 38 ± 12 6.5 ± 0.2

S10 7 1 1350 192 83 80 ± 13 25 ± 7 2.9 ± 0.2L10 8 1 1350 1804 136 127 ± 19 37 ± 10 10.0 ± 0.3S7 9 2 1350 412 99 113 ± 16 37 ± 13 39.2 ± 0.6L7 10 2 1350 1544 158 160 ± 23 44 ± 15 29.2 ± 0.5S8 11 2 1350 1889 99 90 ± 13 27 ± 7 9.3 ± 0.3L8 12 2 1350 1771 158 152 ± 24 45 ± 14 14.5 ± 0.4S5 13 2 1350 1063 99 94 ± 13 11 ± 6 3.1 ± 0.2L5 14 2 1350 1699 158 159 ± 23 26 ± 12 19.6 ± 0.4S6 15 2 1350 369 99 102 ± 14 24 ± 10 28.3 ± 0.5L6 16 2 1350 1301 158 159 ± 23 31 ± 14 30.1 ± 0.6S3 17 3 1350 616 116 120 ± 17 23 ± 12 32.1 ± 0.6L3 18 3 1350 1687 200 214 ± 29 37 ± 17 28.8 ± 0.5S4 19 3 1350 1876 116 85 ± 12 17 ± 6 10.3 ± 0.3L4 20 3 1350 1842 200 187 ± 27 35 ± 15 31.5 ± 0.6S1 21 3 1350 2339 116 105 ± 16 25 ± 9 6.7 ± 0.3L1 22 3 1350 1122 200 219 ± 31 39 ± 18 48.4 ± 0.7S2 23 3 1350 1166 116 103 ± 15 37 ± 8 15.3 ± 0.4L2 24 3 1350 1690 199 177 ± 28 34 ± 13 16.5 ± 0.4

Table 35: RBX 34

44

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1613 136 112 ± 17 34 ± 11 15.5 ± 0.4S24 2 1 1350 750 83 66 ± 11 24 ± 8 16.4 ± 0.4L13 3 1 1350 2353 136 112 ± 18 38 ± 12 16.9 ± 0.4S13 4 1 1350 167 83 76 ± 13 28 ± 8 3.7 ± 0.2L23 5 1 1350 1413 136 123 ± 20 40 ± 14 26.1 ± 0.5S23 6 1 1350 942 83 81 ± 13 25 ± 8 15.6 ± 0.4L22 7 1 1350 72 136 122 ± 20 32 ± 13 2.8 ± 0.2S22 8 1 1350 548 83 79 ± 13 28 ± 8 3.0 ± 0.2L21 9 2 1350 1815 158 143 ± 22 42 ± 14 30.0 ± 0.6S21 10 2 1350 37 100 98 ± 16 29 ± 8 2.9 ± 0.2L20 11 2 1350 1659 158 143 ± 21 44 ± 14 25.8 ± 0.5S20 12 2 1350 154 99 93 ± 17 34 ± 11 3.1 ± 0.2L19 13 2 1350 2194 158 124 ± 19 21 ± 12 23.9 ± 0.5S19 14 2 1350 160 99 99 ± 17 21 ± 9 8.1 ± 0.3L18 15 2 1350 241 158 150 ± 22 32 ± 13 7.7 ± 0.3S18 16 2 1350 2100 99 78 ± 12 16 ± 6 5.8 ± 0.2L17 17 3 1350 2037 201 184 ± 27 32 ± 16 27.1 ± 0.5S17 18 3 1350 257 116 118 ± 17 20 ± 9 5.2 ± 0.2L16 19 3 1350 1578 200 166 ± 26 39 ± 17 34.2 ± 0.6S16 20 3 1350 164 116 113 ± 18 26 ± 10 12.1 ± 0.3L15 21 3 1350 1966 200 159 ± 25 40 ± 15 20.8 ± 0.5S15 22 3 1350 1290 116 124 ± 19 22 ± 11 22.8 ± 0.5L14 23 3 1350 364 200 106 ± 17 41 ± 9 7.5 ± 0.3S14 24 3 1350 796 116 111 ± 18 26 ± 9 13.6 ± 0.4

Table 36: RBX 35

45

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 300 83 69 ± 11 24 ± 7 3.8 ± 0.2L11 2 1 1350 1668 136 100 ± 17 32 ± 10 11.4 ± 0.3S12 3 1 1350 316 83 61 ± 10 23 ± 6 2.5 ± 0.2L12 4 1 1350 1356 136 101 ± 17 37 ± 13 21.6 ± 0.5S9 5 1 1350 652 83 64 ± 11 23 ± 6 7.2 ± 0.3L9 6 1 1350 1844 136 115 ± 20 36 ± 12 13.6 ± 0.4

S10 7 1 1350 351 83 66 ± 11 22 ± 7 3.2 ± 0.2L10 8 1 1350 2428 136 95 ± 18 36 ± 12 15.2 ± 0.4S7 9 2 1350 720 100 73 ± 13 30 ± 9 13.3 ± 0.4L7 10 2 1350 1447 158 117 ± 20 38 ± 13 17.6 ± 0.4S8 11 2 1350 1286 119 90 ± 15 35 ± 13 32.8 ± 0.6L8 12 2 1350 1357 158 137 ± 25 48 ± 17 23.0 ± 0.5S5 13 2 1350 1202 119 89 ± 16 17 ± 10 23.1 ± 0.5L5 14 2 1350 1107 100 108 ± 20 28 ± 13 15.8 ± 0.4S6 15 2 1350 88 100 87 ± 15 23 ± 9 2.4 ± 0.2L6 16 2 1350 1942 158 117 ± 20 22 ± 10 7.0 ± 0.3S3 17 3 1350 1288 116 96 ± 16 23 ± 12 29.2 ± 0.5L3 18 3 1350 1458 202 153 ± 25 32 ± 17 28.5 ± 0.5S4 19 3 1350 221 116 86 ± 16 26 ± 8 2.3 ± 0.2L4 20 3 1350 1782 202 136 ± 23 34 ± 13 12.5 ± 0.3S1 21 3 1350 2483 116 82 ± 15 23 ± 8 7.2 ± 0.3L1 22 3 1350 2059 201 145 ± 24 24 ± 11 11.8 ± 0.3S2 23 3 1350 1430 116 78 ± 14 36 ± 8 5.3 ± 0.2L2 24 3 1350 1692 201 152 ± 27 33 ± 13 11.4 ± 0.3

Table 37: RBX 36

46

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 730 124 152 ± 21 37 ± 12 19.6 ± 0.4S24 2 1 1350 188 64 86 ± 12 25 ± 7 7.2 ± 0.3L13 3 1 1350 1180 124 119 ± 16 34 ± 11 32.1 ± 0.6S13 4 1 1350 313 69 84 ± 12 23 ± 5 3.4 ± 0.2L23 5 1 1350 1807 124 140 ± 19 42 ± 13 30.8 ± 0.6S23 6 1 1350 1627 69 83 ± 13 26 ± 8 29.9 ± 0.6L22 7 1 1350 626 124 158 ± 22 46 ± 16 47.1 ± 0.7S22 8 1 1350 1007 69 77 ± 11 22 ± 5 3.1 ± 0.2L21 9 2 1350 2236 142 172 ± 22 48 ± 15 38.2 ± 0.6S21 10 2 1350 443 88 111 ± 16 32 ± 11 37.5 ± 0.6L20 11 2 1350 987 142 172 ± 23 43 ± 13 21.0 ± 0.5S20 12 2 1350 480 88 100 ± 15 29 ± 8 10.6 ± 0.3L19 13 2 1350 1425 142 172 ± 23 26 ± 15 38.6 ± 0.6S19 14 2 1350 1937 88 88 ± 12 13 ± 6 6.0 ± 0.2L18 15 2 1350 57 142 164 ± 21 28 ± 13 5.0 ± 0.2S18 16 2 1350 216 88 118 ± 17 20 ± 8 9.5 ± 0.3L17 17 3 1350 1743 166 214 ± 29 31 ± 17 21.5 ± 0.5S17 18 3 1350 2083 104 98 ± 13 14 ± 7 4.4 ± 0.2L16 19 3 1350 738 166 167 ± 23 34 ± 14 32.2 ± 0.6S16 20 3 1350 694 104 121 ± 17 25 ± 11 34.0 ± 0.6L15 21 3 1350 1752 166 188 ± 27 41 ± 16 31.0 ± 0.6S15 22 3 1350 1979 104 107 ± 15 16 ± 8 17.1 ± 0.4L14 23 3 1350 237 166 178 ± 24 45 ± 12 5.7 ± 0.2S14 24 3 1350 1038 104 105 ± 15 21 ± 6 4.2 ± 0.2

Table 38: RBX 37

47

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 544 64 80 ± 12 24 ± 6 2.7 ± 0.2L11 2 1 1350 1847 124 149 ± 20 40 ± 12 28.7 ± 0.5S12 3 1 1350 283 70 75 ± 10 22 ± 4 3.1 ± 0.2L12 4 1 1350 1652 124 136 ± 19 36 ± 11 28.9 ± 0.5S9 5 1 1350 1342 68 96 ± 14 33 ± 8 8.6 ± 0.3L9 6 1 1350 718 124 146 ± 21 39 ± 12 28.8 ± 0.5

S10 7 1 1350 855 68 77 ± 11 22 ± 5 5.0 ± 0.2L10 8 1 1350 2326 124 120 ± 16 35 ± 11 17.5 ± 0.4S7 9 2 1350 1023 88 102 ± 14 27 ± 6 2.8 ± 0.2L7 10 2 1350 1390 142 183 ± 26 46 ± 15 31.4 ± 0.6S8 11 2 1350 526 88 100 ± 14 27 ± 6 4.8 ± 0.2L8 12 2 1350 1133 142 138 ± 21 40 ± 14 36.7 ± 0.6S5 13 2 1350 270 88 94 ± 14 12 ± 7 2.5 ± 0.2L5 14 2 1350 1409 142 148 ± 22 26 ± 13 27.3 ± 0.5S6 15 2 1350 657 88 98 ± 13 21 ± 8 23.1 ± 0.5L6 16 2 1350 2218 142 151 ± 21 24 ± 10 14.5 ± 0.4S3 17 3 1350 372 104 127 ± 16 20 ± 8 6.1 ± 0.2L3 18 3 1350 1720 166 213 ± 27 33 ± 16 25.0 ± 0.5S4 19 3 1350 1818 104 101 ± 15 19 ± 7 5.6 ± 0.2L4 20 3 1350 2348 166 170 ± 24 30 ± 13 15.7 ± 0.4S1 21 3 1350 1144 104 112 ± 17 25 ± 8 9.5 ± 0.3L1 22 3 1350 2097 166 177 ± 24 26 ± 12 27.8 ± 0.5S2 23 3 1350 764 104 110 ± 15 39 ± 10 37.1 ± 0.6L2 24 3 1350 1251 166 166 ± 24 30 ± 11 30.7 ± 0.6

Table 39: RBX 38

48

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 1250 124 289 ± 12 N/A N/AS24 2 1 1180 377 70 185 ± 7 N/A N/AL13 3 1 1180 2281 124 278 ± 10 N/A N/AS13 4 1 1180 591 70 185 ± 7 N/A N/AL23 5 1 1180 1426 124 326 ± 12 N/A N/AS23 6 1 1180 542 70 182 ± 8 N/A N/AL22 7 1 1180 365 124 285 ± 10 N/A N/AS22 8 1 1180 552 70 173 ± 7 N/A N/AL21 9 2 1390 1803 142 474 ± 17 N/A N/AS21 10 2 1390 1001 88 291 ± 11 N/A N/AL20 11 2 1390 2199 142 432 ± 25 N/A N/AS20 12 2 1390 624 88 276 ± 12 N/A N/AL19 13 2 1390 2248 142 451 ± 18 N/A N/AS19 14 2 1390 611 88 313 ± 12 N/A N/AL18 15 2 1390 2231 142 450 ± 16 N/A N/AS18 16 2 1390 1143 88 279 ± 11 N/A N/AL17 17 3 1720 1681 167 787 ± 28 N/A N/AS17 18 3 1720 280 104 490 ± 17 N/A N/AL16 19 3 1720 1500 167 662 ± 26 N/A N/AS16 20 3 1720 1040 104 405 ± 15 N/A N/AL15 21 3 1720 1891 166 705 ± 26 N/A N/AS15 22 3 1720 1185 104 468 ± 17 N/A N/AL14 23 3 1720 1971 166 693 ± 27 N/A N/AS14 24 3 1720 1245 104 426 ± 17 N/A N/A

Table 40: RBX 39

49

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 602 70 165 ± 7 N/A N/AL11 2 1 1180 1376 124 350 ± 12 N/A N/AS12 3 1 1180 481 70 177 ± 7 N/A N/AL12 4 1 1180 2234 124 272 ± 10 N/A N/AS9 5 1 1180 923 70 173 ± 7 N/A N/AL9 6 1 1180 1194 124 277 ± 11 N/A N/A

S10 7 1 1180 1006 70 156 ± 6 N/A N/AL10 8 1 1180 1484 124 297 ± 12 N/A N/AS7 9 2 1390 405 89 350 ± 13 N/A N/AL7 10 2 1390 1624 143 523 ± 21 N/A N/AS8 11 2 1390 1344 89 345 ± 13 N/A N/AL8 12 2 1390 1514 142 471 ± 20 N/A N/AS5 13 2 1390 2010 89 289 ± 11 N/A N/AL5 14 2 1390 215 142 520 ± 20 N/A N/AS6 15 2 1390 721 89 311 ± 13 N/A N/AL6 16 2 1390 1667 142 482 ± 19 N/A N/AS3 17 3 1720 1389 104 459 ± 18 N/A N/AL3 18 3 1720 1661 167 697 ± 25 N/A N/AS4 19 3 1720 628 104 448 ± 18 N/A N/AL4 20 3 1720 1900 167 777 ± 30 N/A N/AS1 21 3 1720 366 104 454 ± 18 N/A N/AL1 22 3 1720 734 167 755 ± 28 N/A N/AS2 23 3 1720 2089 104 376 ± 15 N/A N/AL2 24 3 1720 727 167 539 ± 24 N/A N/A

Table 41: RBX 40

50

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 973 125 142 ± 20 40 ± 13 30.0 ± 0.6S24 2 1 1350 569 70 70 ± 10 23 ± 7 3.1 ± 0.2L13 3 1 1350 2238 125 115 ± 17 34 ± 11 22.7 ± 0.5S13 4 1 1350 827 70 74 ± 11 24 ± 7 12.6 ± 0.3L23 5 1 1350 1749 124 137 ± 20 42 ± 13 27.2 ± 0.5S23 6 1 1350 296 70 73 ± 12 21 ± 6 2.1 ± 0.1L22 7 1 1350 1197 124 116 ± 18 36 ± 13 43.1 ± 0.7S22 8 1 1350 523 70 64 ± 9 22 ± 5 4.2 ± 0.2L21 9 2 1350 2272 143 140 ± 20 43 ± 14 28.3 ± 0.5S21 10 2 1350 693 89 110 ± 16 33 ± 11 27.7 ± 0.5L20 11 2 1350 1903 143 160 ± 22 41 ± 13 13.7 ± 0.4S20 12 2 1350 1238 89 82 ± 13 26 ± 8 17.4 ± 0.4L19 13 2 1350 1256 143 135 ± 20 22 ± 13 29.4 ± 0.5S19 14 2 1350 970 89 90 ± 13 15 ± 7 17.2 ± 0.4L18 15 2 1350 964 143 140 ± 20 30 ± 13 26.8 ± 0.5S18 16 2 1350 485 89 87 ± 13 17 ± 6 8.7 ± 0.3L17 17 3 1350 1871 168 180 ± 27 30 ± 15 24.5 ± 0.5S17 18 3 1350 467 104 113 ± 15 19 ± 8 3.9 ± 0.2L16 19 3 1350 1859 167 144 ± 23 28 ± 12 14.5 ± 0.4S16 20 3 1350 2318 104 95 ± 14 19 ± 7 4.0 ± 0.2L15 21 3 1350 1604 167 162 ± 25 35 ± 14 25.6 ± 0.5S15 22 3 1350 479 104 110 ± 16 18 ± 7 4.8 ± 0.2L14 23 3 1350 1152 167 145 ± 22 48 ± 14 32.8 ± 0.6S14 24 3 1350 692 104 92 ± 17 28 ± 14 66.5 ± 0.8

Table 42: RBX 41

51

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1965 64 57 ± 9 20 ± 5 3.7 ± 0.2L11 2 1 1350 2074 125 103 ± 15 31 ± 9 14.2 ± 0.4S12 3 1 1350 524 64 57 ± 9 20 ± 4 3.3 ± 0.2L12 4 1 1350 2472 125 120 ± 18 34 ± 11 17.0 ± 0.4S9 5 1 1350 851 71 66 ± 10 23 ± 6 9.7 ± 0.3L9 6 1 1350 1366 125 132 ± 21 41 ± 15 45.2 ± 0.7

S10 7 1 1350 2053 71 59 ± 9 19 ± 5 4.3 ± 0.2L10 8 1 1350 457 125 112 ± 17 38 ± 12 21.1 ± 0.5S7 9 2 1350 597 89 95 ± 14 31 ± 10 25.2 ± 0.5L7 10 2 1350 2092 144 122 ± 18 34 ± 10 18.1 ± 0.4S8 11 2 1350 922 89 94 ± 14 30 ± 9 26.8 ± 0.5L8 12 2 1350 2176 144 117 ± 19 37 ± 13 27.3 ± 0.5S5 13 2 1350 677 89 107 ± 16 16 ± 10 20.9 ± 0.5L5 14 2 1350 1566 143 139 ± 21 27 ± 14 37.7 ± 0.6S6 15 2 1350 700 89 83 ± 12 21 ± 9 24.4 ± 0.5L6 16 2 1350 1527 143 142 ± 21 27 ± 13 28.4 ± 0.5S3 17 3 1350 1219 105 94 ± 15 17 ± 8 19.5 ± 0.4L3 18 3 1350 2132 168 142 ± 20 25 ± 12 21.2 ± 0.5S4 19 3 1350 114 105 102 ± 16 22 ± 8 6.1 ± 0.2L4 20 3 1350 1573 168 149 ± 23 43 ± 21 75.6 ± 0.9S1 21 3 1350 1645 105 89 ± 15 23 ± 8 12.9 ± 0.4L1 22 3 1350 937 168 167 ± 25 26 ± 11 10.1 ± 0.3S2 23 3 1350 1416 105 95 ± 15 37 ± 9 20.2 ± 0.4L2 24 3 1350 1569 168 142 ± 23 32 ± 12 23.7 ± 0.5

Table 43: RBX 42

52

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 2076 125 269 ± 10 N/A N/AS24 2 1 1180 662 71 180 ± 7 N/A N/AL13 3 1 1180 1762 125 306 ± 11 N/A N/AS13 4 1 1180 281 71 182 ± 7 N/A N/AL23 5 1 1180 1644 125 290 ± 11 N/A N/AS23 6 1 1180 653 71 179 ± 8 N/A N/AL22 7 1 1180 1643 125 297 ± 11 N/A N/AS22 8 1 1180 1061 71 163 ± 7 N/A N/AL21 9 2 1390 1473 144 485 ± 19 N/A N/AS21 10 2 1390 2043 89 266 ± 10 N/A N/AL20 11 2 1390 1575 144 485 ± 17 N/A N/AS20 12 2 1390 706 89 322 ± 14 N/A N/AL19 13 2 1390 1392 144 483 ± 19 N/A N/AS19 14 2 1390 507 89 307 ± 11 N/A N/AL18 15 2 1390 61 144 553 ± 22 N/A N/AS18 16 2 1390 1548 89 262 ± 10 N/A N/AL17 17 3 1720 1295 169 700 ± 25 N/A N/AS17 18 3 1720 1379 105 506 ± 18 N/A N/AL16 19 3 1720 1513 169 750 ± 28 N/A N/AS16 20 3 1720 1190 105 445 ± 16 N/A N/AL15 21 3 1720 1570 169 747 ± 30 N/A N/AS15 22 3 1720 1417 105 527 ± 18 N/A N/AL14 23 3 1720 2168 168 673 ± 26 N/A N/AS14 24 3 1720 1468 105 427 ± 18 N/A N/A

Table 44: RBX 43

53

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 1950 71 164 ± 7 N/A N/AL11 2 1 1180 928 125 323 ± 11 N/A N/AS12 3 1 1180 1427 71 184 ± 7 N/A N/AL12 4 1 1180 1037 125 319 ± 16 N/A N/AS9 5 1 1180 382 71 165 ± 7 N/A N/AL9 6 1 1180 1167 125 321 ± 14 N/A N/A

S10 7 1 1180 686 71 226 ± 9 N/A N/AL10 8 1 1180 877 125 320 ± 13 N/A N/AS7 9 2 1390 1313 90 309 ± 11 N/A N/AL7 10 2 1390 1813 144 498 ± 23 N/A N/AS8 11 2 1390 872 89 335 ± 13 N/A N/AL8 12 2 1390 2294 144 446 ± 18 N/A N/AS5 13 2 1390 831 89 337 ± 13 N/A N/AL5 14 2 1390 1334 144 469 ± 18 N/A N/AS6 15 2 1390 515 89 317 ± 11 N/A N/AL6 16 2 1390 1954 144 432 ± 16 N/A N/AS3 17 3 1720 1380 105 435 ± 16 N/A N/AL3 18 3 1720 1532 169 729 ± 26 N/A N/AS4 19 3 1720 354 105 431 ± 16 N/A N/AL4 20 3 1720 2310 169 635 ± 23 N/A N/AS1 21 3 1720 1182 105 447 ± 17 N/A N/AL1 22 3 1720 1495 169 738 ± 25 N/A N/AS2 23 3 1720 547 105 447 ± 16 N/A N/AL2 24 3 1720 1961 169 756 ± 29 N/A N/A

Table 45: RBX 44

54

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1075 126 81 ± 15 30 ± 9 4.2 ± 0.2S24 2 1 1350 518 72 50 ± 9 22 ± 7 2.3 ± 0.2L13 3 1 1350 1633 126 73 ± 14 30 ± 11 28.0 ± 0.5S13 4 1 1350 534 64 44 ± 8 19 ± 4 1.5 ± 0.1L23 5 1 1350 1605 125 77 ± 14 29 ± 10 4.4 ± 0.2S23 6 1 1350 808 72 29 ± 6 15 ± 4 2.8 ± 0.2L22 7 1 1350 1466 125 78 ± 14 30 ± 10 14.4 ± 0.4S22 8 1 1350 1779 72 45 ± 8 20 ± 6 6.8 ± 0.3L21 9 2 1350 1161 145 103 ± 18 40 ± 13 15.8 ± 0.4S21 10 2 1350 869 90 66 ± 12 28 ± 9 19.9 ± 0.4L20 11 2 1350 1739 145 103 ± 19 37 ± 13 7.1 ± 0.3S20 12 2 1350 919 90 60 ± 12 25 ± 8 8.7 ± 0.3L19 13 2 1350 1838 145 91 ± 16 19 ± 10 9.2 ± 0.3S19 14 2 1350 918 90 57 ± 11 15 ± 7 11.8 ± 0.3L18 15 2 1350 1443 144 75 ± 13 20 ± 8 5.0 ± 0.2S18 16 2 1350 862 64 40 ± 7 10 ± 3 1.3 ± 0.1L17 17 3 1350 1096 169 124 ± 22 26 ± 12 10.1 ± 0.3S17 18 3 1350 1071 105 71 ± 13 17 ± 8 7.4 ± 0.3L16 19 3 1350 1819 169 108 ± 19 29 ± 12 13.4 ± 0.4S16 20 3 1350 2167 119 65 ± 12 18 ± 6 4.2 ± 0.2L15 21 3 1350 1674 169 103 ± 19 32 ± 11 4.4 ± 0.2S15 22 3 1350 633 105 73 ± 13 14 ± 7 9.7 ± 0.3L14 23 3 1350 1639 169 97 ± 17 43 ± 10 5.2 ± 0.2S14 24 3 1350 788 105 64 ± 13 22 ± 6 2.5 ± 0.2

Table 46: RBX 45

55

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 435 74 54 ± 10 24 ± 7 11.8 ± 0.3L11 2 1 1350 273 128 91 ± 15 32 ± 10 3.4 ± 0.2S12 3 1 1350 488 74 53 ± 9 22 ± 6 2.6 ± 0.2L12 4 1 1350 2112 128 91 ± 16 31 ± 10 10.1 ± 0.3S9 5 1 1350 801 74 54 ± 10 25 ± 7 7.9 ± 0.3L9 6 1 1350 1429 127 92 ± 18 31 ± 10 12.1 ± 0.3

S10 7 1 1350 607 74 54 ± 10 22 ± 6 15.5 ± 0.4L10 8 1 1350 2431 127 85 ± 15 34 ± 11 20.6 ± 0.4S7 9 2 1350 433 92 61 ± 11 27 ± 8 19.6 ± 0.4L7 10 2 1350 1658 148 100 ± 17 34 ± 11 11.1 ± 0.3S8 11 2 1350 1069 92 62 ± 10 23 ± 6 3.3 ± 0.2L8 12 2 1350 222 148 113 ± 22 39 ± 13 2.9 ± 0.2S5 13 2 1350 132 92 75 ± 13 15 ± 9 3.5 ± 0.2L5 14 2 1350 1489 148 102 ± 17 22 ± 10 16.6 ± 0.4S6 15 2 1350 1022 92 61 ± 10 17 ± 6 2.4 ± 0.2L6 16 2 1350 1855 148 112 ± 19 26 ± 12 14.1 ± 0.4S3 17 3 1350 48 108 79 ± 13 18 ± 8 3.1 ± 0.2L3 18 3 1350 1817 174 142 ± 23 32 ± 15 24.2 ± 0.5S4 19 3 1350 1058 108 72 ± 12 19 ± 7 3.9 ± 0.2L4 20 3 1350 1666 174 128 ± 22 32 ± 13 21.1 ± 0.5S1 21 3 1350 906 108 84 ± 16 27 ± 10 14.1 ± 0.4L1 22 3 1350 1398 174 138 ± 23 29 ± 14 25.2 ± 0.5S2 23 3 1350 1218 108 70 ± 13 35 ± 7 11.6 ± 0.3L2 24 3 1350 2149 174 105 ± 19 28 ± 10 11.8 ± 0.3

Table 47: RBX 46

56

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 1278 128 334 ± 13 N/A N/AS24 2 1 1180 505 74 202 ± 8 N/A N/AL13 3 1 1180 2133 128 283 ± 11 N/A N/AS13 4 1 1180 848 74 195 ± 7 N/A N/AL23 5 1 1180 1849 128 295 ± 11 N/A N/AS23 6 1 1180 318 74 189 ± 8 N/A N/AL22 7 1 1180 1632 128 311 ± 12 N/A N/AS22 8 1 1180 594 74 180 ± 8 N/A N/AL21 9 2 1390 2041 148 474 ± 16 N/A N/AS21 10 2 1390 295 92 335 ± 13 N/A N/AL20 11 2 1390 1956 148 529 ± 18 N/A N/AS20 12 2 1390 1220 92 294 ± 13 N/A N/AL19 13 2 1390 1391 148 513 ± 20 N/A N/AS19 14 2 1390 510 92 323 ± 13 N/A N/AL18 15 2 1390 1486 148 528 ± 18 N/A N/AS18 16 2 1390 911 92 295 ± 11 N/A N/AL17 17 3 1720 1170 175 677 ± 24 N/A N/AS17 18 3 1720 735 108 576 ± 19 N/A N/AL16 19 3 1720 2021 175 692 ± 27 N/A N/AS16 20 3 1720 1212 108 432 ± 16 N/A N/AL15 21 3 1720 1609 175 678 ± 26 N/A N/AS15 22 3 1720 168 108 499 ± 20 N/A N/AL14 23 3 1720 1700 174 767 ± 29 N/A N/AS14 24 3 1720 135 108 514 ± 21 N/A N/A

Table 48: RBX 47

57

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 562 75 180 ± 7 N/A N/AL11 2 1 1180 890 128 328 ± 11 N/A N/AS12 3 1 1180 554 75 184 ± 7 N/A N/AL12 4 1 1180 2195 128 303 ± 11 N/A N/AS9 5 1 1180 2227 74 161 ± 6 N/A N/AL9 6 1 1180 1778 128 353 ± 15 N/A N/A

S10 7 1 1180 941 74 198 ± 8 N/A N/AL10 8 1 1180 969 128 334 ± 13 N/A N/AS7 9 2 1390 1656 92 315 ± 12 N/A N/AL7 10 2 1390 2286 148 494 ± 18 N/A N/AS8 11 2 1390 1021 92 295 ± 11 N/A N/AL8 12 2 1390 2225 148 457 ± 19 N/A N/AS5 13 2 1390 625 92 300 ± 11 N/A N/AL5 14 2 1390 2285 148 448 ± 26 N/A N/AS6 15 2 1390 1864 92 304 ± 12 N/A N/AL6 16 2 1390 699 148 516 ± 20 N/A N/AS3 17 3 1720 1991 108 435 ± 17 N/A N/AL3 18 3 1720 1449 175 778 ± 28 N/A N/AS4 19 3 1720 2117 108 367 ± 14 N/A N/AL4 20 3 1720 1082 175 780 ± 32 N/A N/AS1 21 3 1720 353 108 474 ± 18 N/A N/AL1 22 3 1720 1967 175 763 ± 28 N/A N/AS2 23 3 1720 1216 108 430 ± 18 N/A N/AL2 24 3 1720 2410 174 635 ± 29 N/A N/A

Table 49: RBX 48

58

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1259 129 120 ± 20 38 ± 13 28.5 ± 0.5S24 2 1 1350 667 75 66 ± 10 24 ± 7 16.0 ± 0.4L13 3 1 1350 101 129 118 ± 20 39 ± 13 4.8 ± 0.2S13 4 1 1350 259 75 65 ± 11 23 ± 7 2.1 ± 0.1L23 5 1 1350 242 128 126 ± 19 36 ± 11 3.9 ± 0.2S23 6 1 1350 671 75 70 ± 11 23 ± 7 16.9 ± 0.4L22 7 1 1350 2309 128 112 ± 17 33 ± 9 7.7 ± 0.3S22 8 1 1350 529 75 66 ± 10 24 ± 6 2.8 ± 0.2L21 9 2 1350 1754 148 155 ± 22 46 ± 15 29.1 ± 0.5S21 10 2 1350 2136 92 75 ± 12 24 ± 7 8.0 ± 0.3L20 11 2 1350 2222 148 124 ± 18 37 ± 12 18.8 ± 0.4S20 12 2 1350 791 92 103 ± 16 32 ± 10 21.1 ± 0.5L19 13 2 1350 1642 148 123 ± 19 20 ± 12 23.9 ± 0.5S19 14 2 1350 198 92 96 ± 16 19 ± 9 7.7 ± 0.3L18 15 2 1350 440 148 136 ± 20 31 ± 13 18.6 ± 0.4S18 16 2 1350 915 92 97 ± 14 22 ± 10 35.7 ± 0.6L17 17 3 1350 1455 177 174 ± 26 31 ± 16 31.3 ± 0.6S17 18 3 1350 668 108 109 ± 16 19 ± 8 14.1 ± 0.4L16 19 3 1350 2188 177 140 ± 21 27 ± 11 11.6 ± 0.3S16 20 3 1350 166 108 108 ± 17 25 ± 9 10.9 ± 0.3L15 21 3 1350 1888 176 163 ± 26 38 ± 15 18.3 ± 0.4S15 22 3 1350 1703 108 103 ± 15 18 ± 8 26.0 ± 0.5L14 23 3 1350 1978 176 143 ± 21 46 ± 13 6.3 ± 0.2S14 24 3 1350 977 108 97 ± 16 23 ± 8 21.6 ± 0.5

Table 50: RBX 49

59

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 789 75 74 ± 13 26 ± 8 11.3 ± 0.3L11 2 1 1350 2143 129 95 ± 14 31 ± 10 19.8 ± 0.4S12 3 1 1350 642 75 66 ± 11 26 ± 9 23.4 ± 0.5L12 4 1 1350 1354 129 113 ± 19 36 ± 12 19.4 ± 0.4S9 5 1 1350 974 75 66 ± 11 24 ± 7 12.6 ± 0.4L9 6 1 1350 2185 129 99 ± 16 31 ± 9 13.4 ± 0.4

S10 7 1 1350 592 75 66 ± 11 23 ± 7 15.0 ± 0.4L10 8 1 1350 1287 129 113 ± 19 39 ± 13 28.0 ± 0.5S7 9 2 1350 1335 92 93 ± 14 31 ± 11 28.6 ± 0.5L7 10 2 1350 1550 149 135 ± 20 40 ± 13 22.0 ± 0.5S8 11 2 1350 944 92 87 ± 14 31 ± 11 2.6 ± 0.2L8 12 2 1350 1660 149 119 ± 20 36 ± 11 9.7 ± 0.3S5 13 2 1350 1065 92 73 ± 11 11 ± 7 2.7 ± 0.2L5 14 2 1350 205 149 118 ± 19 21 ± 10 5.1 ± 0.2S6 15 2 1350 689 92 78 ± 12 20 ± 8 17.7 ± 0.4L6 16 2 1350 1571 148 142 ± 21 32 ± 15 33.1 ± 0.6S3 17 3 1350 10 108 96 ± 16 21 ± 8 3.4 ± 0.2L3 18 3 1350 1120 178 169 ± 25 35 ± 18 37.6 ± 0.6S4 19 3 1350 884 108 87 ± 14 21 ± 8 17.9 ± 0.4L4 20 3 1350 1116 178 165 ± 26 35 ± 16 37.3 ± 0.6S1 21 3 1350 1054 108 98 ± 15 26 ± 9 8.0 ± 0.3L1 22 3 1350 1529 178 168 ± 25 31 ± 15 31.3 ± 0.6S2 23 3 1350 1773 108 101 ± 16 39 ± 9 6.2 ± 0.2L2 24 3 1350 1407 177 153 ± 25 33 ± 13 23.2 ± 0.5

Table 51: RBX 50

60

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 982 129 132 ± 21 40 ± 14 28.6 ± 0.5S24 2 1 1350 1047 75 63 ± 10 23 ± 5 2.8 ± 0.2L13 3 1 1350 1382 129 111 ± 18 37 ± 12 17.3 ± 0.4S13 4 1 1350 258 75 73 ± 11 24 ± 5 2.7 ± 0.2L23 5 1 1350 1584 129 118 ± 18 39 ± 13 27.4 ± 0.5S23 6 1 1350 746 75 78 ± 13 26 ± 9 17.6 ± 0.4L22 7 1 1350 2156 129 96 ± 15 29 ± 9 6.0 ± 0.2S22 8 1 1350 328 75 69 ± 11 23 ± 6 2.7 ± 0.2L21 9 2 1350 1347 149 136 ± 20 42 ± 14 24.7 ± 0.5S21 10 2 1350 790 93 92 ± 15 30 ± 10 16.9 ± 0.4L20 11 2 1350 1296 149 143 ± 21 47 ± 16 40.4 ± 0.6S20 12 2 1350 546 93 76 ± 13 26 ± 9 2.7 ± 0.2L19 13 2 1350 2008 149 139 ± 21 20 ± 11 9.7 ± 0.3S19 14 2 1350 713 93 87 ± 14 19 ± 8 17.8 ± 0.4L18 15 2 1350 1078 149 134 ± 20 30 ± 13 29.4 ± 0.5S18 16 2 1350 1332 93 93 ± 15 21 ± 9 21.4 ± 0.5L17 17 3 1350 1108 179 170 ± 24 44 ± 22 71.5 ± 0.9S17 18 3 1350 1209 108 101 ± 16 18 ± 9 15.0 ± 0.4L16 19 3 1350 214 178 139 ± 21 30 ± 10 8.0 ± 0.3S16 20 3 1350 413 108 100 ± 16 24 ± 9 18.1 ± 0.4L15 21 3 1350 1300 178 148 ± 24 39 ± 17 38.0 ± 0.6S15 22 3 1350 470 108 102 ± 15 18 ± 8 3.7 ± 0.2L14 23 3 1350 1839 178 151 ± 23 48 ± 13 23.1 ± 0.5S14 24 3 1350 1343 108 86 ± 14 23 ± 7 19.1 ± 0.4

Table 52: RBX 51

61

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 200 76 76 ± 13 25 ± 8 3.8 ± 0.2L11 2 1 1350 1015 130 104 ± 15 34 ± 11 3.5 ± 0.2S12 3 1 1350 323 75 69 ± 10 24 ± 6 4.5 ± 0.2L12 4 1 1350 2320 129 109 ± 17 32 ± 10 8.2 ± 0.3S9 5 1 1350 311 75 72 ± 11 25 ± 7 2.6 ± 0.2L9 6 1 1350 2108 129 108 ± 19 34 ± 11 17.5 ± 0.4

S10 7 1 1350 2049 75 53 ± 8 20 ± 4 3.4 ± 0.2L10 8 1 1350 2548 129 99 ± 16 33 ± 11 10.9 ± 0.3S7 9 2 1350 1204 93 98 ± 15 32 ± 12 37.9 ± 0.6L7 10 2 1350 1373 149 142 ± 21 44 ± 14 30.3 ± 0.6S8 11 2 1350 2290 93 77 ± 13 26 ± 8 3.8 ± 0.2L8 12 2 1350 1359 149 146 ± 24 44 ± 16 19.3 ± 0.4S5 13 2 1350 396 93 84 ± 13 14 ± 9 14.2 ± 0.4L5 14 2 1350 753 149 127 ± 20 26 ± 13 25.9 ± 0.5S6 15 2 1350 375 93 82 ± 12 21 ± 8 6.5 ± 0.3L6 16 2 1350 2075 149 115 ± 18 24 ± 10 6.7 ± 0.3S3 17 3 1350 1865 109 86 ± 14 17 ± 8 12.2 ± 0.3L3 18 3 1350 1695 179 168 ± 25 33 ± 15 22.2 ± 0.5S4 19 3 1350 2333 109 79 ± 13 18 ± 7 4.7 ± 0.2L4 20 3 1350 1843 179 159 ± 24 33 ± 14 22.3 ± 0.5S1 21 3 1350 799 109 92 ± 16 26 ± 9 16.0 ± 0.4L1 22 3 1350 2284 179 157 ± 23 29 ± 14 27.0 ± 0.5S2 23 3 1350 1930 109 74 ± 12 34 ± 7 2.4 ± 0.2L2 24 3 1350 1561 178 138 ± 25 32 ± 12 17.0 ± 0.4

Table 53: RBX 52

62

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 988 130 120 ± 19 35 ± 12 20.2 ± 0.4S24 2 1 1350 1993 76 59 ± 9 21 ± 5 9.6 ± 0.3L13 3 1 1350 1490 130 114 ± 18 36 ± 12 8.9 ± 0.3S13 4 1 1350 584 76 65 ± 10 22 ± 6 7.9 ± 0.3L23 5 1 1350 1805 121 119 ± 19 39 ± 12 5.8 ± 0.2S23 6 1 1350 381 76 69 ± 12 22 ± 6 5.2 ± 0.2L22 7 1 1350 1377 130 124 ± 19 39 ± 13 23.5 ± 0.5S22 8 1 1350 320 76 64 ± 10 24 ± 6 4.0 ± 0.2L21 9 2 1350 2244 150 127 ± 19 38 ± 13 23.1 ± 0.5S21 10 2 1350 1031 94 84 ± 13 26 ± 7 8.1 ± 0.3L20 11 2 1350 1516 150 140 ± 22 45 ± 15 25.1 ± 0.5S20 12 2 1350 1581 93 71 ± 13 27 ± 9 19.2 ± 0.4L19 13 2 1350 206 150 132 ± 20 20 ± 11 4.6 ± 0.2S19 14 2 1350 627 93 81 ± 13 16 ± 7 12.9 ± 0.4L18 15 2 1350 2137 150 103 ± 16 23 ± 10 9.8 ± 0.3S18 16 2 1350 873 93 88 ± 14 19 ± 9 28.4 ± 0.5L17 17 3 1350 1526 180 149 ± 22 30 ± 15 33.8 ± 0.6S17 18 3 1350 719 109 94 ± 14 22 ± 11 31.7 ± 0.6L16 19 3 1350 1662 180 126 ± 20 27 ± 10 10.4 ± 0.3S16 20 3 1350 1424 109 92 ± 15 21 ± 8 16.9 ± 0.4L15 21 3 1350 2210 180 135 ± 22 33 ± 13 6.9 ± 0.3S15 22 3 1350 506 109 101 ± 15 17 ± 7 3.5 ± 0.2L14 23 3 1350 1452 180 136 ± 22 47 ± 12 12.6 ± 0.3S14 24 3 1350 272 109 99 ± 16 24 ± 9 2.9 ± 0.2

Table 54: RBX 53

63

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1048 76 52 ± 9 20 ± 5 5.7 ± 0.2L11 2 1 1350 1476 130 85 ± 15 32 ± 10 20.1 ± 0.4S12 3 1 1350 1626 76 44 ± 8 21 ± 7 13.3 ± 0.4L12 4 1 1350 996 130 98 ± 18 35 ± 12 11.3 ± 0.3S9 5 1 1350 913 76 55 ± 10 24 ± 8 20.9 ± 0.5L9 6 1 1350 939 130 86 ± 17 33 ± 12 18.7 ± 0.4

S10 7 1 1350 587 76 50 ± 10 22 ± 7 14.5 ± 0.4L10 8 1 1350 459 130 75 ± 14 32 ± 11 20.9 ± 0.5S7 9 2 1350 158 94 81 ± 15 34 ± 12 5.9 ± 0.2L7 10 2 1350 2178 150 94 ± 17 36 ± 12 17.4 ± 0.4S8 11 2 1350 130 94 73 ± 14 29 ± 9 5.8 ± 0.2L8 12 2 1350 1606 150 85 ± 17 33 ± 11 4.4 ± 0.2S5 13 2 1350 1680 119 77 ± 14 14 ± 8 4.9 ± 0.2L5 14 2 1350 2091 150 76 ± 14 20 ± 9 19.9 ± 0.4S6 15 2 1350 2016 94 46 ± 8 14 ± 4 3.7 ± 0.2L6 16 2 1350 1579 150 106 ± 20 27 ± 13 17.3 ± 0.4S3 17 3 1350 2094 109 56 ± 10 14 ± 6 10.3 ± 0.3L3 18 3 1350 1737 180 122 ± 21 31 ± 15 23.5 ± 0.5S4 19 3 1350 1483 109 61 ± 11 18 ± 6 11.8 ± 0.3L4 20 3 1350 2252 180 101 ± 19 25 ± 11 10.9 ± 0.3S1 21 3 1350 1990 109 62 ± 12 23 ± 7 9.9 ± 0.3L1 22 3 1350 2350 180 110 ± 20 24 ± 11 17.0 ± 0.4S2 23 3 1350 1033 109 66 ± 12 36 ± 7 3.7 ± 0.2L2 24 3 1350 55 180 101 ± 22 26 ± 12 2.3 ± 0.2

Table 55: RBX 54

64

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 229 132 137 ± 21 39 ± 12 5.0 ± 0.2S24 2 1 1350 1629 79 65 ± 10 25 ± 8 27.4 ± 0.5L13 3 1 1350 1938 132 129 ± 19 39 ± 13 22.4 ± 0.5S13 4 1 1350 425 79 72 ± 11 26 ± 9 21.6 ± 0.5L23 5 1 1350 811 132 85 ± 13 30 ± 10 24.4 ± 0.5S23 6 1 1350 312 65 67 ± 11 22 ± 6 2.0 ± 0.1L22 7 1 1350 2160 132 102 ± 16 32 ± 9 6.8 ± 0.3S22 8 1 1350 578 79 65 ± 11 24 ± 7 3.0 ± 0.2L21 9 2 1350 2279 153 133 ± 20 38 ± 12 16.7 ± 0.4S21 10 2 1350 2312 96 81 ± 13 27 ± 8 23.3 ± 0.5L20 11 2 1350 1146 153 133 ± 20 42 ± 14 26.9 ± 0.5S20 12 2 1350 1869 95 74 ± 13 26 ± 8 6.6 ± 0.3L19 13 2 1350 708 153 143 ± 22 28 ± 15 26.2 ± 0.5S19 14 2 1350 1003 95 69 ± 11 13 ± 5 2.7 ± 0.2L18 15 2 1350 1742 153 127 ± 20 32 ± 13 11.1 ± 0.3S18 16 2 1350 1673 95 86 ± 13 19 ± 8 12.2 ± 0.3L17 17 3 1350 1765 184 160 ± 23 30 ± 14 22.2 ± 0.5S17 18 3 1350 1142 111 98 ± 14 20 ± 9 21.8 ± 0.5L16 19 3 1350 1909 184 141 ± 22 28 ± 12 19.8 ± 0.4S16 20 3 1350 2018 111 83 ± 12 20 ± 8 4.1 ± 0.2L15 21 3 1350 1822 184 155 ± 24 37 ± 14 18.6 ± 0.4S15 22 3 1350 1862 111 93 ± 14 16 ± 7 11.5 ± 0.3L14 23 3 1350 2081 184 130 ± 21 43 ± 11 7.9 ± 0.3S14 24 3 1350 1045 112 85 ± 14 21 ± 7 2.2 ± 0.2

Table 56: RBX 55

65

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1874 79 70 ± 11 23 ± 6 3.1 ± 0.2L11 2 1 1350 1811 132 123 ± 18 39 ± 12 23.6 ± 0.5S12 3 1 1350 527 79 80 ± 12 27 ± 8 17.2 ± 0.4L12 4 1 1350 1589 132 145 ± 22 42 ± 14 27.6 ± 0.5S9 5 1 1350 321 79 74 ± 11 25 ± 6 4.7 ± 0.2L9 6 1 1350 1297 132 134 ± 21 38 ± 14 28.9 ± 0.5

S10 7 1 1350 812 79 73 ± 12 26 ± 8 24.7 ± 0.5L10 8 1 1350 123 132 137 ± 22 44 ± 15 5.2 ± 0.2S7 9 2 1350 809 119 129 ± 19 41 ± 14 37.4 ± 0.6L7 10 2 1350 1148 153 153 ± 22 46 ± 15 39.1 ± 0.6S8 11 2 1350 224 119 127 ± 19 35 ± 10 3.7 ± 0.2L8 12 2 1350 436 153 147 ± 25 46 ± 15 25.3 ± 0.5S5 13 2 1350 119 96 103 ± 16 18 ± 9 4.5 ± 0.2L5 14 2 1350 992 153 134 ± 20 25 ± 13 34.3 ± 0.6S6 15 2 1350 1085 119 114 ± 16 25 ± 11 33.2 ± 0.6L6 16 2 1350 1260 153 138 ± 20 29 ± 14 36.6 ± 0.6S3 17 3 1350 2203 112 99 ± 14 18 ± 9 21.4 ± 0.5L3 18 3 1350 2052 185 177 ± 25 29 ± 13 14.2 ± 0.4S4 19 3 1350 112 112 105 ± 16 24 ± 10 4.8 ± 0.2L4 20 3 1350 1785 185 189 ± 28 34 ± 14 18.8 ± 0.4S1 21 3 1350 175 112 111 ± 18 29 ± 10 14.8 ± 0.4L1 22 3 1350 1112 184 197 ± 28 37 ± 18 50.2 ± 0.7S2 23 3 1350 2011 112 87 ± 13 36 ± 7 5.6 ± 0.2L2 24 3 1350 1408 184 159 ± 25 33 ± 14 30.3 ± 0.6

Table 57: RBX 56

66

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 2012 133 123 ± 18 33 ± 11 12.0 ± 0.3S24 2 1 1350 286 79 78 ± 11 25 ± 7 4.5 ± 0.2L13 3 1 1350 2334 133 110 ± 17 36 ± 12 16.9 ± 0.4S13 4 1 1350 1941 79 70 ± 11 22 ± 5 5.2 ± 0.2L23 5 1 1350 2346 133 131 ± 20 38 ± 12 21.4 ± 0.5S23 6 1 1350 2507 79 71 ± 12 23 ± 6 11.5 ± 0.3L22 7 1 1350 2399 133 138 ± 20 41 ± 13 22.8 ± 0.5S22 8 1 1350 557 79 79 ± 12 26 ± 7 7.5 ± 0.3L21 9 2 1350 726 154 178 ± 25 56 ± 17 39.6 ± 0.6S21 10 2 1350 1920 96 88 ± 13 25 ± 7 11.3 ± 0.3L20 11 2 1350 1172 154 157 ± 22 45 ± 14 23.5 ± 0.5S20 12 2 1350 476 95 97 ± 15 32 ± 9 3.2 ± 0.2L19 13 2 1350 1572 153 170 ± 24 28 ± 16 37.0 ± 0.6S19 14 2 1350 452 95 95 ± 14 19 ± 9 21.8 ± 0.5L18 15 2 1350 1299 153 149 ± 21 35 ± 16 40.8 ± 0.6S18 16 2 1350 703 119 131 ± 19 29 ± 14 40.6 ± 0.6L17 17 3 1350 1897 186 170 ± 24 29 ± 14 21.8 ± 0.5S17 18 3 1350 2336 112 114 ± 16 19 ± 8 7.3 ± 0.3L16 19 3 1350 1556 186 158 ± 25 34 ± 16 32.5 ± 0.6S16 20 3 1350 2036 112 91 ± 14 20 ± 8 15.9 ± 0.4L15 21 3 1350 437 186 180 ± 28 44 ± 17 31.7 ± 0.6S15 22 3 1350 1481 112 111 ± 16 18 ± 9 19.3 ± 0.4L14 23 3 1350 1303 186 162 ± 24 51 ± 14 33.6 ± 0.6S14 24 3 1350 1378 112 114 ± 19 26 ± 9 20.2 ± 0.4

Table 58: RBX 57

67

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 582 79 72 ± 11 25 ± 7 20.0 ± 0.4L11 2 1 1350 794 133 125 ± 19 39 ± 13 21.8 ± 0.5S12 3 1 1350 2174 79 54 ± 9 20 ± 4 2.5 ± 0.2L12 4 1 1350 2071 133 99 ± 16 31 ± 9 14.5 ± 0.4S9 5 1 1350 1872 79 66 ± 11 24 ± 7 4.4 ± 0.2L9 6 1 1350 2161 133 103 ± 18 32 ± 11 24.5 ± 0.5

S10 7 1 1350 287 79 73 ± 11 24 ± 6 3.3 ± 0.2L10 8 1 1350 1433 133 119 ± 18 40 ± 14 28.4 ± 0.5S7 9 2 1350 725 96 104 ± 17 38 ± 13 22.4 ± 0.5L7 10 2 1350 1497 154 153 ± 22 48 ± 17 58.2 ± 0.8S8 11 2 1350 782 96 85 ± 13 29 ± 8 14.6 ± 0.4L8 12 2 1350 2213 154 122 ± 21 36 ± 12 8.8 ± 0.3S5 13 2 1350 1183 96 87 ± 14 14 ± 9 20.8 ± 0.5L5 14 2 1350 2165 154 109 ± 17 19 ± 9 12.7 ± 0.4S6 15 2 1350 946 96 83 ± 13 20 ± 7 8.6 ± 0.3L6 16 2 1350 1857 154 135 ± 21 29 ± 13 15.6 ± 0.4S3 17 3 1350 2316 113 87 ± 13 16 ± 7 12.9 ± 0.4L3 18 3 1350 1820 187 178 ± 27 31 ± 16 14.7 ± 0.4S4 19 3 1350 471 113 93 ± 14 21 ± 8 3.7 ± 0.2L4 20 3 1350 1957 187 163 ± 25 35 ± 15 19.8 ± 0.4S1 21 3 1350 2001 113 89 ± 15 24 ± 8 7.6 ± 0.3L1 22 3 1350 1798 187 185 ± 27 30 ± 14 16.8 ± 0.4S2 23 3 1350 2159 113 78 ± 12 34 ± 7 12.0 ± 0.3L2 24 3 1350 1395 187 130 ± 22 30 ± 11 17.6 ± 0.4

Table 59: RBX 58

68

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1651 133 80 ± 15 32 ± 11 14.3 ± 0.4S24 2 1 1350 909 80 54 ± 10 23 ± 7 15.3 ± 0.4L13 3 1 1350 2335 133 82 ± 15 29 ± 10 3.7 ± 0.2S13 4 1 1350 532 80 61 ± 10 24 ± 7 9.5 ± 0.3L23 5 1 1350 169 133 83 ± 16 34 ± 10 7.4 ± 0.3S23 6 1 1350 299 79 54 ± 10 21 ± 7 1.5 ± 0.1L22 7 1 1350 2283 133 82 ± 14 31 ± 10 13.8 ± 0.4S22 8 1 1350 857 79 49 ± 9 22 ± 7 12.6 ± 0.4L21 9 2 1350 1262 154 107 ± 18 40 ± 14 27.9 ± 0.5S21 10 2 1350 297 97 71 ± 13 24 ± 7 2.1 ± 0.2L20 11 2 1350 1436 154 109 ± 19 41 ± 14 20.5 ± 0.4S20 12 2 1350 1420 97 63 ± 12 26 ± 8 13.6 ± 0.4L19 13 2 1350 2190 154 99 ± 17 20 ± 11 11.1 ± 0.3S19 14 2 1350 2340 97 57 ± 10 14 ± 5 2.7 ± 0.2L18 15 2 1350 1456 154 95 ± 16 28 ± 12 20.6 ± 0.4S18 16 2 1350 1014 97 63 ± 11 17 ± 7 2.2 ± 0.2L17 17 3 1350 647 187 82 ± 14 20 ± 11 25.6 ± 0.5S17 18 3 1350 275 113 81 ± 14 21 ± 9 2.2 ± 0.2L16 19 3 1350 1688 187 127 ± 22 32 ± 14 18.9 ± 0.4S16 20 3 1350 1246 113 78 ± 14 21 ± 8 17.0 ± 0.4L15 21 3 1350 1592 187 119 ± 21 36 ± 14 20.2 ± 0.4S15 22 3 1350 1009 113 80 ± 13 15 ± 6 3.7 ± 0.2L14 23 3 1350 1899 187 115 ± 20 45 ± 12 5.8 ± 0.2S14 24 3 1350 1057 113 76 ± 14 21 ± 7 4.2 ± 0.2

Table 60: RBX 59

69

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 595 80 45 ± 9 21 ± 6 9.2 ± 0.3L11 2 1 1350 702 134 83 ± 15 35 ± 12 23.5 ± 0.5S12 3 1 1350 1901 80 37 ± 7 18 ± 5 2.2 ± 0.2L12 4 1 1350 2439 133 75 ± 14 32 ± 11 18.7 ± 0.4S9 5 1 1350 1947 80 45 ± 9 22 ± 5 1.9 ± 0.1L9 6 1 1350 1438 133 86 ± 17 33 ± 11 11.3 ± 0.3

S10 7 1 1350 590 80 47 ± 9 21 ± 6 7.7 ± 0.3L10 8 1 1350 2201 133 70 ± 13 30 ± 10 18.4 ± 0.4S7 9 2 1350 27 97 65 ± 12 27 ± 7 2.4 ± 0.2L7 10 2 1350 1841 155 104 ± 19 39 ± 13 17.7 ± 0.4S8 11 2 1350 446 97 69 ± 12 30 ± 10 22.9 ± 0.5L8 12 2 1350 1401 154 95 ± 19 39 ± 14 13.7 ± 0.4S5 13 2 1350 1279 97 61 ± 11 12 ± 7 12.5 ± 0.3L5 14 2 1350 1393 154 97 ± 19 23 ± 12 20.3 ± 0.4S6 15 2 1350 383 97 28 ± 5 12 ± 3 1.9 ± 0.1L6 16 2 1350 1919 154 110 ± 19 30 ± 13 21.1 ± 0.5S3 17 3 1350 2171 188 65 ± 12 18 ± 9 15.8 ± 0.4L3 18 3 1350 2383 113 122 ± 21 29 ± 14 10.3 ± 0.3S4 19 3 1350 1101 188 57 ± 10 22 ± 10 40.0 ± 0.6L4 20 3 1350 1093 113 104 ± 19 30 ± 13 18.6 ± 0.4S1 21 3 1350 207 187 76 ± 14 27 ± 10 2.7 ± 0.2L1 22 3 1350 1593 113 122 ± 22 26 ± 13 16.8 ± 0.4S2 23 3 1350 1641 187 65 ± 12 37 ± 7 10.3 ± 0.3L2 24 3 1350 1614 113 105 ± 21 30 ± 11 7.2 ± 0.3

Table 61: RBX 60

70

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 1039 134 411 ± 14 N/A N/AS24 2 1 1180 269 80 257 ± 9 N/A N/AL13 3 1 1180 2328 134 374 ± 12 N/A N/AS13 4 1 1180 155 80 292 ± 10 N/A N/AL23 5 1 1180 2031 134 368 ± 12 N/A N/AS23 6 1 1180 882 80 263 ± 10 N/A N/AL22 7 1 1180 1665 134 420 ± 14 N/A N/AS22 8 1 1180 577 80 255 ± 9 N/A N/AL21 9 2 1390 1081 155 737 ± 25 N/A N/AS21 10 2 1390 2182 97 344 ± 12 N/A N/AL20 11 2 1390 723 154 714 ± 25 N/A N/AS20 12 2 1390 904 97 437 ± 17 N/A N/AL19 13 2 1390 2357 154 594 ± 20 N/A N/AS19 14 2 1390 898 97 441 ± 19 N/A N/AL18 15 2 1390 1827 154 662 ± 22 N/A N/AS18 16 2 1390 290 97 417 ± 13 N/A N/AL17 17 3 1720 1736 190 999 ± 33 N/A N/AS17 18 3 1720 434 114 627 ± 20 N/A N/AL16 19 3 1720 1697 189 953 ± 32 N/A N/AS16 20 3 1720 1894 114 581 ± 19 N/A N/AL15 21 3 1720 1997 189 1013 ± 35 N/A N/AS15 22 3 1720 178 114 637 ± 22 N/A N/AL14 23 3 1720 2212 188 907 ± 32 N/A N/AS14 24 3 1720 1181 113 583 ± 22 N/A N/A

Table 62: RBX 61

71

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 465 80 265 ± 9 N/A N/AL11 2 1 1180 1264 134 403 ± 13 N/A N/AS12 3 1 1180 109 80 251 ± 12 N/A N/AL12 4 1 1180 1214 134 416 ± 14 N/A N/AS9 5 1 1180 400 80 255 ± 13 N/A N/AL9 6 1 1180 122 134 445 ± 18 N/A N/A

S10 7 1 1180 201 80 250 ± 9 N/A N/AL10 8 1 1180 1867 134 338 ± 12 N/A N/AS7 9 2 1390 1976 97 391 ± 13 N/A N/AL7 10 2 1390 1411 155 627 ± 22 N/A N/AS8 11 2 1390 1207 97 405 ± 14 N/A N/AL8 12 2 1390 1777 155 635 ± 25 N/A N/AS5 13 2 1390 2058 97 339 ± 13 N/A N/AL5 14 2 1390 899 155 648 ± 24 N/A N/AS6 15 2 1390 792 97 470 ± 15 N/A N/AL6 16 2 1390 2295 155 553 ± 19 N/A N/AS3 17 3 1720 2229 114 559 ± 19 N/A N/AL3 18 3 1720 1832 190 1019 ± 31 N/A N/AS4 19 3 1720 1549 114 543 ± 19 N/A N/AL4 20 3 1720 1621 190 881 ± 30 N/A N/AS1 21 3 1720 1266 114 577 ± 19 N/A N/AL1 22 3 1720 2131 190 872 ± 26 N/A N/AS2 23 3 1720 1100 114 588 ± 22 N/A N/AL2 24 3 1720 1404 190 922 ± 33 N/A N/A

Table 63: RBX 62

72

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 1826 134 421 ± 15 N/A N/AS24 2 1 1180 1008 81 252 ± 8 N/A N/AL13 3 1 1180 2204 134 360 ± 13 N/A N/AS13 4 1 1180 145 81 228 ± 8 N/A N/AL23 5 1 1180 2104 134 327 ± 11 N/A N/AS23 6 1 1180 144 81 236 ± 10 N/A N/AL22 7 1 1180 729 134 422 ± 15 N/A N/AS22 8 1 1180 131 81 289 ± 11 N/A N/AL21 9 2 1390 1618 155 714 ± 23 N/A N/AS21 10 2 1390 765 98 455 ± 14 N/A N/AL20 11 2 1390 2291 155 579 ± 18 N/A N/AS20 12 2 1390 253 98 412 ± 16 N/A N/AL19 13 2 1390 1149 155 664 ± 22 N/A N/AS19 14 2 1390 75 98 435 ± 15 N/A N/AL18 15 2 1390 2048 155 610 ± 21 N/A N/AS18 16 2 1390 181 97 461 ± 17 N/A N/AL17 17 3 1720 2304 191 938 ± 29 N/A N/AS17 18 3 1720 978 114 698 ± 21 N/A N/AL16 19 3 1720 2024 191 945 ± 32 N/A N/AS16 20 3 1720 1095 114 633 ± 21 N/A N/AL15 21 3 1720 1696 191 1078 ± 38 N/A N/AS15 22 3 1720 2362 114 548 ± 19 N/A N/AL14 23 3 1720 80 191 1062 ± 37 N/A N/AS14 24 3 1720 1326 114 519 ± 19 N/A N/A

Table 64: RBX 63

73

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 1244 82 261 ± 9 N/A N/AL11 2 1 1180 1374 135 428 ± 14 N/A N/AS12 3 1 1180 291 82 268 ± 9 N/A N/AL12 4 1 1180 1177 135 422 ± 14 N/A N/AS9 5 1 1180 793 82 270 ± 10 N/A N/AL9 6 1 1180 1634 135 427 ± 16 N/A N/A

S10 7 1 1180 1601 82 242 ± 9 N/A N/AL10 8 1 1180 1531 135 424 ± 15 N/A N/AS7 9 2 1390 1032 99 450 ± 15 N/A N/AL7 10 2 1390 2386 157 626 ± 20 N/A N/AS8 11 2 1390 1886 99 379 ± 14 N/A N/AL8 12 2 1390 2093 157 658 ± 25 N/A N/AS5 13 2 1390 655 99 440 ± 16 N/A N/AL5 14 2 1390 2047 157 576 ± 21 N/A N/AS6 15 2 1390 1364 99 480 ± 16 N/A N/AL6 16 2 1390 1830 157 611 ± 22 N/A N/AS3 17 3 1720 2082 115 477 ± 16 N/A N/AL3 18 3 1720 1147 202 1059 ± 32 N/A N/AS4 19 3 1720 2219 115 519 ± 18 N/A N/AL4 20 3 1720 1898 202 1038 ± 35 N/A N/AS1 21 3 1720 1463 115 561 ± 20 N/A N/AL1 22 3 1720 1776 202 944 ± 30 N/A N/AS2 23 3 1720 2017 115 465 ± 16 N/A N/AL2 24 3 1720 1405 202 988 ± 37 N/A N/A

Table 65: RBX 64

74

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1365 137 146 ± 23 42 ± 14 24.2 ± 0.5S24 2 1 1350 191 84 75 ± 12 25 ± 8 4.3 ± 0.2L13 3 1 1350 2026 137 98 ± 15 32 ± 10 18.1 ± 0.4S13 4 1 1350 111 84 79 ± 13 27 ± 9 23.2 ± 0.5L23 5 1 1350 1135 137 117 ± 17 40 ± 14 37.2 ± 0.6S23 6 1 1350 654 83 75 ± 13 24 ± 7 12.7 ± 0.4L22 7 1 1350 1487 137 116 ± 18 35 ± 11 14.8 ± 0.4S22 8 1 1350 374 83 72 ± 12 26 ± 7 2.8 ± 0.2L21 9 2 1350 2232 159 136 ± 20 42 ± 13 16.0 ± 0.4S21 10 2 1350 402 100 102 ± 16 32 ± 11 4.6 ± 0.2L20 11 2 1350 2297 159 136 ± 20 43 ± 14 22.7 ± 0.5S20 12 2 1350 1371 100 83 ± 14 30 ± 11 25.8 ± 0.5L19 13 2 1350 1829 159 138 ± 22 23 ± 13 23.7 ± 0.5S19 14 2 1350 930 100 96 ± 15 21 ± 10 30.6 ± 0.6L18 15 2 1350 1493 159 140 ± 20 33 ± 14 26.7 ± 0.5S18 16 2 1350 620 100 98 ± 15 25 ± 13 43.5 ± 0.7L17 17 3 1350 2141 203 157 ± 23 31 ± 15 27.2 ± 0.5S17 18 3 1350 1615 116 136 ± 20 24 ± 11 11.6 ± 0.3L16 19 3 1350 1535 203 154 ± 24 32 ± 12 14.2 ± 0.4S16 20 3 1350 432 116 97 ± 16 26 ± 12 26.0 ± 0.5L15 21 3 1350 1917 203 171 ± 27 38 ± 15 11.8 ± 0.3S15 22 3 1350 1821 116 111 ± 17 21 ± 10 27.0 ± 0.5L14 23 3 1350 1926 203 147 ± 23 44 ± 13 7.6 ± 0.3S14 24 3 1350 1879 116 87 ± 14 22 ± 7 11.0 ± 0.3

Table 66: RBX 65

75

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 606 84 79 ± 13 28 ± 10 38.5 ± 0.6L11 2 1 1350 2177 137 110 ± 16 36 ± 13 25.1 ± 0.5S12 3 1 1350 568 84 75 ± 12 26 ± 7 7.4 ± 0.3L12 4 1 1350 439 137 143 ± 22 44 ± 14 23.2 ± 0.5S9 5 1 1350 539 84 77 ± 12 28 ± 8 2.2 ± 0.2L9 6 1 1350 2158 137 125 ± 21 34 ± 10 6.6 ± 0.3

S10 7 1 1350 1333 84 85 ± 13 28 ± 9 17.8 ± 0.4L10 8 1 1350 2520 137 106 ± 17 36 ± 10 5.3 ± 0.2S7 9 2 1350 619 100 96 ± 14 34 ± 13 44.1 ± 0.7L7 10 2 1350 2150 160 135 ± 20 40 ± 13 22.0 ± 0.5S8 11 2 1350 1241 100 99 ± 16 31 ± 10 20.4 ± 0.4L8 12 2 1350 1361 160 142 ± 24 43 ± 14 18.5 ± 0.4S5 13 2 1350 656 100 93 ± 15 16 ± 10 19.8 ± 0.4L5 14 2 1350 2371 159 128 ± 20 25 ± 11 14.9 ± 0.4S6 15 2 1350 1068 100 83 ± 12 19 ± 6 4.0 ± 0.2L6 16 2 1350 1088 159 144 ± 22 29 ± 13 25.6 ± 0.5S3 17 3 1350 2191 117 88 ± 13 18 ± 9 18.8 ± 0.4L3 18 3 1350 2258 203 182 ± 27 31 ± 15 14.4 ± 0.4S4 19 3 1350 1851 117 85 ± 14 21 ± 9 21.4 ± 0.5L4 20 3 1350 1528 203 182 ± 27 36 ± 15 28.5 ± 0.5S1 21 3 1350 2323 117 94 ± 15 25 ± 8 5.9 ± 0.2L1 22 3 1350 2249 203 182 ± 26 32 ± 15 35.2 ± 0.6S2 23 3 1350 929 117 109 ± 17 41 ± 10 23.1 ± 0.5L2 24 3 1350 1512 203 162 ± 26 35 ± 14 17.6 ± 0.4

Table 67: RBX 66

76

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 752 138 132 ± 22 42 ± 15 28.8 ± 0.5S24 2 1 1350 921 84 64 ± 10 24 ± 8 23.1 ± 0.5L13 3 1 1350 100 138 133 ± 22 46 ± 16 4.8 ± 0.2S13 4 1 1350 955 84 82 ± 14 26 ± 8 8.5 ± 0.3L23 5 1 1350 1201 137 124 ± 19 44 ± 16 41.9 ± 0.6S23 6 1 1350 631 84 75 ± 13 27 ± 9 25.8 ± 0.5L22 7 1 1350 2276 137 108 ± 17 35 ± 11 22.6 ± 0.5S22 8 1 1350 1029 84 70 ± 11 25 ± 7 4.4 ± 0.2L21 9 2 1350 1498 160 145 ± 22 46 ± 16 26.5 ± 0.5S21 10 2 1350 866 100 93 ± 15 29 ± 10 26.5 ± 0.5L20 11 2 1350 1394 160 155 ± 25 46 ± 16 29.0 ± 0.5S20 12 2 1350 1607 101 82 ± 14 29 ± 8 10.4 ± 0.3L19 13 2 1350 1511 160 115 ± 18 21 ± 11 21.5 ± 0.5S19 14 2 1350 1280 101 78 ± 13 17 ± 7 12.5 ± 0.3L18 15 2 1350 742 160 134 ± 21 38 ± 17 35.3 ± 0.6S18 16 2 1350 2111 101 72 ± 11 16 ± 6 6.4 ± 0.2L17 17 3 1350 2187 204 156 ± 24 31 ± 15 27.7 ± 0.5S17 18 3 1350 2488 117 107 ± 17 21 ± 10 12.8 ± 0.4L16 19 3 1350 1691 204 154 ± 24 35 ± 15 27.8 ± 0.5S16 20 3 1350 2263 117 84 ± 14 18 ± 7 3.7 ± 0.2L15 21 3 1350 1402 204 172 ± 28 41 ± 17 25.1 ± 0.5S15 22 3 1350 797 117 118 ± 18 22 ± 10 20.7 ± 0.4L14 23 3 1350 1127 204 171 ± 26 57 ± 17 40.0 ± 0.6S14 24 3 1350 932 117 106 ± 18 26 ± 10 24.0 ± 0.5

Table 68: RBX 67

77

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 1949 84 65 ± 10 22 ± 7 3.0 ± 0.2L11 2 1 1350 2289 138 105 ± 16 34 ± 11 16.2 ± 0.4S12 3 1 1350 292 84 72 ± 12 25 ± 7 1.8 ± 0.1L12 4 1 1350 1467 138 123 ± 19 37 ± 13 25.7 ± 0.5S9 5 1 1350 2099 84 61 ± 10 23 ± 6 4.2 ± 0.2L9 6 1 1350 1664 138 133 ± 23 40 ± 13 18.4 ± 0.4

S10 7 1 1350 1321 84 69 ± 12 25 ± 8 13.0 ± 0.4L10 8 1 1350 1306 138 98 ± 17 37 ± 12 16.0 ± 0.4S7 9 2 1350 1053 101 84 ± 13 28 ± 8 4.4 ± 0.2L7 10 2 1350 1542 160 136 ± 21 41 ± 14 27.2 ± 0.5S8 11 2 1350 947 101 97 ± 16 32 ± 10 19.9 ± 0.4L8 12 2 1350 1451 160 119 ± 22 40 ± 14 19.9 ± 0.4S5 13 2 1350 842 101 92 ± 15 15 ± 8 6.7 ± 0.3L5 14 2 1350 1998 160 139 ± 22 27 ± 13 20.5 ± 0.4S6 15 2 1350 449 101 83 ± 13 23 ± 9 22.5 ± 0.5L6 16 2 1350 1554 159 137 ± 21 31 ± 15 39.2 ± 0.6S3 17 3 1350 265 117 103 ± 17 22 ± 11 3.0 ± 0.2L3 18 3 1350 1722 205 182 ± 29 37 ± 18 25.6 ± 0.5S4 19 3 1350 238 117 84 ± 13 22 ± 7 3.1 ± 0.2L4 20 3 1350 76 205 181 ± 28 33 ± 19 9.1 ± 0.3S1 21 3 1350 908 117 108 ± 19 31 ± 12 16.3 ± 0.4L1 22 3 1350 1119 205 170 ± 26 36 ± 18 41.8 ± 0.6S2 23 3 1350 2367 117 84 ± 14 36 ± 8 7.3 ± 0.3L2 24 3 1350 1117 204 167 ± 28 41 ± 17 34.5 ± 0.6

Table 69: RBX 68

78

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1350 1672 138 104 ± 18 34 ± 10 9.3 ± 0.3S24 2 1 1350 549 85 63 ± 10 24 ± 5 2.4 ± 0.2L13 3 1 1350 1837 138 114 ± 19 39 ± 13 20.7 ± 0.5S13 4 1 1350 856 85 68 ± 11 24 ± 7 14.6 ± 0.4L23 5 1 1350 2305 138 100 ± 17 36 ± 11 7.3 ± 0.3S23 6 1 1350 575 85 70 ± 13 24 ± 7 3.0 ± 0.2L22 7 1 1350 2257 138 93 ± 16 31 ± 11 6.3 ± 0.2S22 8 1 1350 1158 85 56 ± 9 25 ± 8 19.8 ± 0.4L21 9 2 1350 1431 161 128 ± 20 43 ± 14 29.1 ± 0.5S21 10 2 1350 2085 101 67 ± 11 23 ± 7 2.2 ± 0.2L20 11 2 1350 1608 160 119 ± 19 37 ± 12 9.9 ± 0.3S20 12 2 1350 120 101 83 ± 16 31 ± 9 3.8 ± 0.2L19 13 2 1350 1540 160 122 ± 19 22 ± 12 24.4 ± 0.5S19 14 2 1350 1423 101 77 ± 14 19 ± 10 29.6 ± 0.5L18 15 2 1350 1559 160 123 ± 20 33 ± 15 35.5 ± 0.6S18 16 2 1350 1825 101 79 ± 13 18 ± 8 15.1 ± 0.4L17 17 3 1350 1151 205 171 ± 27 36 ± 17 24.7 ± 0.5S17 18 3 1350 1074 118 100 ± 16 19 ± 9 9.9 ± 0.3L16 19 3 1350 1686 205 150 ± 25 32 ± 13 15.7 ± 0.4S16 20 3 1350 147 118 102 ± 18 27 ± 11 7.7 ± 0.3L15 21 3 1350 2034 205 131 ± 22 35 ± 13 13.8 ± 0.4S15 22 3 1350 2317 118 85 ± 14 16 ± 8 12.2 ± 0.3L14 23 3 1350 1755 205 147 ± 24 49 ± 14 16.5 ± 0.4S14 24 3 1350 1895 117 82 ± 14 21 ± 6 7.2 ± 0.3

Table 70: RBX 69

79

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1350 605 85 67 ± 12 25 ± 8 19.3 ± 0.4L11 2 1 1350 1616 183 107 ± 17 35 ± 12 20.9 ± 0.5S12 3 1 1350 737 85 70 ± 12 27 ± 8 18.8 ± 0.4L12 4 1 1350 2381 183 120 ± 19 37 ± 13 24.0 ± 0.5S9 5 1 1350 404 85 70 ± 11 26 ± 6 3.4 ± 0.2L9 6 1 1350 1293 183 120 ± 21 39 ± 14 25.0 ± 0.5

S10 7 1 1350 635 85 72 ± 12 26 ± 8 23.6 ± 0.5L10 8 1 1350 2147 183 96 ± 15 34 ± 10 13.4 ± 0.4S7 9 2 1350 688 101 91 ± 15 33 ± 10 14.2 ± 0.4L7 10 2 1350 240 161 139 ± 22 41 ± 14 6.2 ± 0.2S8 11 2 1350 1324 101 81 ± 13 28 ± 9 18.2 ± 0.4L8 12 2 1350 1758 161 126 ± 22 40 ± 13 17.7 ± 0.4S5 13 2 1350 11 101 85 ± 15 15 ± 7 3.5 ± 0.2L5 14 2 1350 1165 161 120 ± 20 24 ± 11 5.6 ± 0.2S6 15 2 1350 38 101 76 ± 13 20 ± 8 2.2 ± 0.2L6 16 2 1350 2299 161 122 ± 20 28 ± 13 16.5 ± 0.4S3 17 3 1350 1268 118 102 ± 16 21 ± 10 19.1 ± 0.4L3 18 3 1350 1577 206 166 ± 25 37 ± 18 35.4 ± 0.6S4 19 3 1350 1187 118 84 ± 14 22 ± 10 22.9 ± 0.5L4 20 3 1350 1713 206 157 ± 26 32 ± 14 11.1 ± 0.3S1 21 3 1350 1479 119 94 ± 16 27 ± 10 12.5 ± 0.3L1 22 3 1350 2414 206 163 ± 27 27 ± 14 16.7 ± 0.4S2 23 3 1350 1892 118 82 ± 14 37 ± 8 5.5 ± 0.2L2 24 3 1350 1533 205 148 ± 26 34 ± 12 13.2 ± 0.4

Table 71: RBX 70

80

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

L24 1 1 1180 894 138 348 ± 14 N/A N/AS24 2 1 1180 761 85 194 ± 8 N/A N/AL13 3 1 1180 1806 138 323 ± 12 N/A N/AS13 4 1 1180 588 85 209 ± 8 N/A N/AL23 5 1 1180 1309 138 312 ± 12 N/A N/AS23 6 1 1180 798 85 212 ± 10 N/A N/AL22 7 1 1180 1159 138 308 ± 12 N/A N/AS22 8 1 1180 1217 85 181 ± 7 N/A N/AL21 9 2 1390 1750 162 566 ± 20 N/A N/AS21 10 2 1390 1281 102 391 ± 16 N/A N/AL20 11 2 1390 1103 161 677 ± 24 N/A N/AS20 12 2 1390 96 102 389 ± 18 N/A N/AL19 13 2 1390 1470 161 530 ± 22 N/A N/AS19 14 2 1390 696 101 342 ± 14 N/A N/AL18 15 2 1390 1552 161 619 ± 24 N/A N/AS18 16 2 1390 1963 101 341 ± 14 N/A N/AL17 17 3 1720 2138 208 810 ± 30 N/A N/AS17 18 3 1720 1208 118 484 ± 18 N/A N/AL16 19 3 1720 2096 208 716 ± 30 N/A N/AS16 20 3 1720 1480 118 457 ± 18 N/A N/AL15 21 3 1720 1562 208 783 ± 34 N/A N/AS15 22 3 1720 1272 118 491 ± 18 N/A N/AL14 23 3 1720 2267 207 667 ± 27 N/A N/AS14 24 3 1720 905 118 524 ± 22 N/A N/A

Table 72: RBX 71

81

Tower ADC Ch. HVB HV Serial No. UI Gain TTU Gain AP3 Charge AP rate(V) (relative) (ADC Counts) (ADC Counts) (%)

S11 1 1 1180 875 85 201 ± 8 N/A N/AL11 2 1 1180 1475 139 302 ± 12 N/A N/AS12 3 1 1180 666 85 203 ± 8 N/A N/AL12 4 1 1180 246 139 371 ± 14 N/A N/AS9 5 1 1180 509 85 203 ± 8 N/A N/AL9 6 1 1180 1179 139 337 ± 14 N/A N/A

S10 7 1 1180 1936 85 192 ± 7 N/A N/AL10 8 1 1180 1358 139 355 ± 13 N/A N/AS7 9 2 1390 1329 102 385 ± 15 N/A N/AL7 10 2 1390 940 162 521 ± 22 N/A N/AS8 11 2 1390 2110 102 278 ± 11 N/A N/AL8 12 2 1390 1767 162 457 ± 19 N/A N/AS5 13 2 1390 2020 102 273 ± 11 N/A N/AL5 14 2 1390 1496 162 467 ± 18 N/A N/AS6 15 2 1390 1275 102 333 ± 13 N/A N/AL6 16 2 1390 1388 162 613 ± 24 N/A N/AS3 17 3 1720 1904 118 425 ± 15 N/A N/AL3 18 3 1720 2098 210 831 ± 30 N/A N/AS4 19 3 1720 1247 118 461 ± 19 N/A N/AL4 20 3 1720 1707 210 826 ± 33 N/A N/AS1 21 3 1720 893 118 492 ± 20 N/A N/AL1 22 3 1720 1723 209 867 ± 32 N/A N/AS2 23 3 1720 2153 118 387 ± 15 N/A N/AL2 24 3 1720 1128 208 782 ± 33 N/A N/A

Table 73: RBX 72

82

References

[1] See http://highenergy.phys.ttu.edu for engineering drawings and test data.

[2] N. Akchurin, et al, HF Readout Box Design and Parameters (No Tail-Catcher) CMS Note-2001/048

[3] N. Akchurin, et al, Assembly and Test of RBX1-4 for the HF Beam Tests in 2002, CMS IN–2002/051(2002).

[4] O. Atramentov et al, High-voltage Distribution for the CMS Hadronic Forward Calorimeter (HF),CMS IN 2005/XXX.

[5] N. Akchurin and H. Kim, A Study on the Afterpulse of Photomultiplier Tubes, Submitted to Nucl.Instr. and Meth. A.

83