Aratua-1 / 712835
108W6614
16111805 - 813Project/CMS No.:WTG No.:
WTG Drw No.:
GE Wind Energy 1.6MW
Project schematics
Kunde /Customer:
Steuerspannung / Control Voltage
Nennspannung / Rated Voltage
Frequenz / Frequency 50 / 60Hz
690V / 400V
230VAC / 24VDC
BioEnergy
-
9
-REV
1.6 xle13
GI=
2 next
SEE PLM
Project cover page
SEE PLM
105050000 14-JUN-2011
of
Sh.
Project schematics
ENGINEER
DRAWN
CHECKED
ISSUED
105050000 14-JUN-2011
DATESIGNATUREGE Energy GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
SEE PLM
SEE PLM
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2011 GENERAL ELECTRIC COMPANY
Project schematicsSEE PLM SEE PLM
108W6614
REV DESCRIPTION
0 1
C HE CK ED B Y R EV IS ED B Y
2
GE Energy
DRAWN
ISSUED
3
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
5 6
COMPONENT
COMP NO.
74
COMP-DRW. NO.
COMP-PART NO.
8
TYPE
N / A
new releaseECO1112257
7/21/2019 Wind - Bioenergy
2/159
Date Revision Revision description
Revision overview
Page name ECR / ECO
108W6614 Aratua-1 / 712835
14.Jun.2011 new release all ECO1112257
2
GI=
next31previous
SEE PLM
105050000 14-JUN-2011
of
Sh.
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2011 GENERAL ELECTRIC COMPANY
108W6614
SEE PLM SEE PLM
REV DESCRIPTION
0 1
C HE CK ED B Y R EV IS ED B Y
2
GE Energy
DRAWN
ISSUED
3
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
4
Modification information
5 6
COMPONENT
COMP NO.
7
COMP-DRW. NO.
COMP-PART NO.
8
TYPE
1.6 xleREV
-
9
-3
new releaseECO1112257
N/A
Project Schematics
-
7/21/2019 Wind - Bioenergy
3/159
Comp. Drw No.
Component overview
Comp. Part No.Identifier
Aratua-1 / 712835108W6614
RevisionComponentCable No.
3
GI=
next=DOCU/12previous
SEE PLM
105050000 14-JUN-2011
of
Sh.
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2011 GENERAL ELECTRIC COMPANY
108W6614
SEE PLM SEE PLM
REV DESCRIPTION
0 1
C HE CK ED B Y R EV IS ED B Y
2
GE Energy
DRAWN
ISSUED
3
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
4
Table of contents
5 6
COMPONENT
COMP NO.
7
COMP-DRW. NO.
COMP-PART NO.
8
TYPE
1.6 xleREV
-
9
-3
new releaseECO1112257
N/A
Project Schematics
0
3
1
3
4
7
8
6
16
26
36
15
N / A
N / A
=GI N / A 108W6614-General InformationN / A
=DOCU N / A 104W6321CSystem Cover Page 1.5 ESS
=OneLines N / A 107W5365EOne Line Drawings
=PDC 107W5379P001 107W4611BPower Distribution Cabinet
=CFC 107W5379P001 107W4611BConverter Filter Cabinet
=MCC 107W5379P001 107W4611BMain Control Cabinet
=CBC 107W5379P001 107W4611BConverter Bridge Cabinet
=TB 107W5345P001 107W6155BTop Box
=GT 104W3938P001 104W3892FGearbox 60 Hz
=GE 108W5204P001 104W2742CGenerator
=SR 104W5966P001 104W5916ASlipring
=PCS 104W2609P001 104W4611CPitch System and Battery Box
=PCS 104W2609P001 104W4611CPitch System and Battery Box
=PCS 104W2609P001 104W4611CPitch System and Battery Box
=PCS 104W2610P001 104W4611CPitch System
7/21/2019 Wind - Bioenergy
4/159
230V / 24VDC690V / 400V
50 / 60 Hz
System Cover Page 1.5 ESS
Aratua-1 / 712835
108W661416111805 - 813
N / A
104W6321
System Cover Page 1.5 ESS
Project/CMS No.:WTG No.:WTG Drw No.:
GE Wind Energy 1.6MW
Cover Page
Comp-Part No.:
Comp-Drw. No.:
Comp No.:Component:
Customer:
Control Voltage:Rated Voltage:
Frequency:
BioEnergy
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C18
next2DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
N / A
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
System Cover Page 1.5 ESS
COMPONENT
65
System Cover Page 1.5 ESS
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
=GI/3
0
DESCRIPTIONREV
previous
7/21/2019 Wind - Bioenergy
5/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C28
next3DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Modification Page 1.5 ESS
COMPONENT
65
Modification Page
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
1
0
DESCRIPTIONREV
previous
10/09/0804/25/08
Updated the following sections: MCC, TBA
actual statepagechangerevisiondate
12/18/07
12/4/07 - Copied from 104W5562P001. Updated DTA Schematic (PDC, CFC, CBC, and MCC) and Top Box Schematic with changes for production(both given new part numbers). Updated following sections from previous schematic: PSCB, OneLines.
03/07/08 B Updated the following sections: CFC, OneLines, MCC & TB
Updated borderUpdated sections CFC, CBC, TB, GT, SR
Updated section TB11/10/08
Updated sections: One-Line,PDC,CFC,MCC,TB,GT,GE,SRC03/18/09
7/21/2019 Wind - Bioenergy
6/159
ContentsPage Page designation
Column x: created autom. but modified manually
Page supplementary field Date User. X
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C38
next4DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Contents 1.5 ESS
COMPONENT
65
Contents
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
2
0
DESCRIPTIONREV
previous
X
X
X
X
X
X
X
X
X
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
03.Nov.2009
02.Dez.2009
02.Dez.2009
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Project schematics 1.6 ESS
Modification information
Table of contents
System Cover Page 1.5 ESS
Modification Page
Contents
Contents
Contents
Contents
Contents
Contents
One Lines Cover Page (Indexed)
One Lines Modification Page
Down Tower Line Up One Line Drawing
Top Box 690 V Power One Line Drawing
Top Box 400/230 V Power One Line Drawing
Control Hardware One Line
Control Hardware One Line
Control Hardware One Line
Power Distribution Cabinet Cover Page
Power Distribution Cabinet Modification Page
Power Distribution Cabinet TVSS
Power Distribution Cabinet Main Breaker and Synch Contactor
Power Distribution Cabinet Conv Line Fuses, DC Bus Charger, & Line Filter
Power Distribution Cabinet 690V Distribution
Power Distribution Cabinet Main Breaker and Synch Contactor
Converter Filter Cabinet Cover page
Converter Filter Cabinet Modification Page
Converter Filter Cabinet Control Power Distribution 1
Converter Filter Cabinet ROV Contactors Rtr Conns and Reactor
=GI+/1
=GI+/2
=GI+/3
=DOCU+/1
=DOCU+/2
=DOCU+/3
=DOCU+/4
=DOCU+/5
=DOCU+/6
=DOCU+/7
=DOCU+/8
=OneLines+/1
=OneLines+/2
=OneLines+/3
=OneLines+/4
=OneLines+/5
=OneLines+/6
=OneLines+/7
=OneLines+/8
=PDC+/1
=PDC+/2
=PDC+/3
=PDC+/4
=PDC+/5
=PDC+/6
=PDC+/7
=CFC+/1
=CFC+/2
=CFC+/3
=CFC+/4
1.5/50Hz
7/21/2019 Wind - Bioenergy
7/159
ContentsPage Page designation
Column x: created autom. but modified manually
Page supplementary field Date User. X
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C48
next5DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Contents 1.5 ESS
COMPONENT
65
Contents
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
3
0
DESCRIPTIONREV
previous
X
X
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
02.Dez.2009
02.Dez.2009
23.Mai.2011
03.Nov.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
02.Dez.2009
23.Mai.2011
23.Mai.2011
23.Mai.2011
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Converter Filter Cabinet Stator Current Feedback CTs and Heaters
Converter Filter Cabinet Line Filter
Main Control Cabinet Cover Page
Main Control Cabinet Modification Page
Main Control Cabinet Fans
Main Control Cabinet Cold Weather Heating
Main Control Cabinet UPS 24V Power
Main Control Cabinet Ethernet Switches and UCSA
Main Control Cabinet Door Mounted Switches
Main Control Cabinet Safety Chain
Main Control Cabinet Optional Temp Monitors and Contact Inputs
Main Control Cabinet Optional Relay Outputs
Main Control Cabinet MACC
Main Control Cabinet AEAD
Main Control Cabinet AEAD
Main Control Cabinet AEAD
Main Control Cabinet AEAD
Main Control Cabinet AEAD
Main Control Cabinet AEAA
Main Control Cabinet AEAA
Main Control Cabinet AEPS
Main Control Cabinet AEBI1
Main Control Cabinet AEBI2
Main Control Cabinet WEOR
Main Control Cabinet Control Power Distribution
Main Control Cabinet Control Power Distribution
Main Control Cabinet FiberOptics
Converter Bridge Cabinet Cover Page
Converter Bridge Cabinet Modification Information
Converter Bridge Cabinet Line Converter Bridge 1
=CFC+/5
=CFC+/6
=MCC+/1
=MCC+/2
=MCC+/3
=MCC+/4
=MCC+/5
=MCC+/6
=MCC+/7
=MCC+/8
=MCC+/9
=MCC+/10
=MCC+/11
=MCC+/12
=MCC+/13
=MCC+/14
=MCC+/15
=MCC+/16
=MCC+/17
=MCC+/18
=MCC+/19
=MCC+/20
=MCC+/21
=MCC+/22
=MCC+/23
=MCC+/24
=MCC+/25
=CBC+/1
=CBC+/2
=CBC+/3
7/21/2019 Wind - Bioenergy
8/159
ContentsPage Page designation
Column x: created autom. but modified manually
Page supplementary field Date User. X
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C58
next6DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Contents 1.5 ESS
COMPONENT
65
Contents
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
4
0
DESCRIPTIONREV
previous
X
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Converter Bridge Cabinet DC Capacitor Bank
Converter Bridge Cabinet Rotor Converter Bridge 2
Converter Bridge Cabinet and MCC Fans and Heaters
Top Box Cover Page
Top Box Modification Page
Top Box Elementary Yaw Motors
Top Box Elementary Auxiliaries
Top Box Elementary Auxiliaries Heating
Top Box Elementary Auxiliaries Lube and Cooling
Top Box Elementary Auxiliaries Heaters and Pumps
Top Box Elementary Fans and Heaters
Top Box Elementary Yaw Brakes
Top Box Elementary Tower Lights and Top Box Heaters
Top Box Elementary Tower Lights and Top Box Heaters
Top Box Elementary Control Power / Solenoid Valves
Top Box Elementary Control Power Distribution
Top Box Elementary Serial Link Between PWA Cards
Top Box Elementary Safety Status
Top Box Elementary Yaw Contactor Pilot Relays/ Control Breaker Status
Top Box Elementary Signals To Pitch system
Top Box Elementary Differential Dry- Contact Inputs
Top Box Elementary Differential Dry - Contact Inputs
Top Box Elementary Spare Digital Inputs/ Temperature Inputs
Top Box Elementary Contactor Pilot Relays
Top Box Elementary Spare Contactor Pilot Relays
Top Box Elementary Gbx Particle / Speed Inputs
Top Box Elementary PT100 Temperatures
Top Box Elementary PT100 Temperatures
Top Box Elementary Analog Inputs
Top Box Elementary Meteorological Devices
=CBC+/4
=CBC+/5
=CBC+/6
=TB+/1
=TB+/2
=TB+/3
=TB+/4
=TB+/5
=TB+/6
=TB+/7
=TB+/8
=TB+/9
=TB+/10
=TB+/11
=TB+/12
=TB+/13
=TB+/14
=TB+/15
=TB+/16
=TB+/17
=TB+/18
=TB+/19
=TB+/20
=TB+/21
=TB+/22
=TB+/23
=TB+/24
=TB+/25
=TB+/26
=TB+/27
7/21/2019 Wind - Bioenergy
9/159
ContentsPage Page designation
Column x: created autom. but modified manually
Page supplementary field Date User. X
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C68
next7DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Contents 1.5 ESS
COMPONENT
65
Contents
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
5
0
DESCRIPTIONREV
previous
X
X
X
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
Documentation
Documentation
Documentation
Documentation
1.5 50Hz CWE ESS UL/CSA
1.5 50Hz ESS
1.5 50Hz ESS
1.5 50Hz ESS
1.5 50Hz ESS
1.5 50Hz ESS
1.5 50Hz ESS
1.5 50Hz ESS
1.5 50Hz ESS
Top Box Elementary Vibration Monitor
Top Box Elementary Surge Suppressors
Top Box Elementary Surge Suppressors
Top Box Elementary CBM Unit
cover page - 50Hz ESS
Modification information
general information
Junction Box Layout - Control Terminal Box
Junction Box Layout - Power Terminal Box
Contents
Temprerature sensors
Level & pressure sensors
pressure sensors & valves
Drives 690V
Heaters 690V/230V
Cover Page
Modification Information
General Information
Table of Contents
Generator Stator Connection
Generator Rotor Connection
Generator Fan Internal Cooling
Generator Fan External Coolong
Standby Heater
Motor Protection Fan Trip
Rotation Speed / Brush Wear
Winding Temperature/ Bearing Temperature
Slipring Cover Page
Slipring Modification information
Slipring General Information
=TB+/28
=TB+/29
=TB+/30
=TB+/31
=GT+/1
=GT+/2
=GT+/3
=GT+/4
=GT+/4a
=GT+/5
=GT+/10
=GT+/11
=GT+/12
=GT+/13
=GT+/14
=GE+S1/1
=GE+S1/2
=GE+S1/3
=GE+S1/4
=GE+S1/5
=GE+S1/6
=GE+S1/7
=GE+S1/8
=GE+S1/9
=GE+S1/10
=GE+S1/11
=GE+S1/12
=SR+/1
=SR+/2
=SR+/3
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz X
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
1.5\1.6kW 50Hz
X
9876543210
7/21/2019 Wind - Bioenergy
10/159
ContentsPage Page designation
Column x: created autom. but modified manually
Page supplementary field Date User. X
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C78
next8DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Contents 1.5 ESS
COMPONENT
65
Contents
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
6
0
DESCRIPTIONREV
previous
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
105050000
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
23.Mai.2011
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Documentation
Slipring transformer supply pitch 400V/230V
Slipring transformer supply pitch 24V / signal
Axis 1 Cover Page
Axis 1 Modification Information
Axis Box 1 Power Connections to Converter
Axis Box 1 Contactors and Limit Switches
Axis Box 1 Motor Connections
Axis Box 1 - Signal Connections to Power Converter & Battery Box
Axis Box 1 - Signals from Center Box & 230Vac Fan and Heater Controls
Battery Box 1
Battery Box 1
Battery Box 1 Axis-to-Battery Connector
Axis 2 Cover Page
Axis 2 Modification Information
Axis Box 2 Power Connections to Converter
Axis Box 2 Contactors and Limit Switches
Axis Box 2 Motor Connections
Axis Box 2 - Signal Connections to Power Converter & Battery Box
Axis Box 2 - Signals from Center Box & 230Vac Fan and Heater Controls
Battery Box 2
Battery Box 2
Battery Box 2 Axis-to-Battery Connector
Axis 3 Cover Page
Axis 3 Modification Information
Axis Box 3 Power Connections to Converter
Axis Box 3 Contactors and Limit Switches
Axis Box 3 Motor Connections
Axis Box 3 - Signal Connections to Power Converter & Battery Box
Axis Box 3 - Signals from Center Box & 230Vac Fan and Heater Controls
Battery Box 3
=SR+/4
=SR+/5
=PCS+Ax1/1
=PCS+Ax1/2
=PCS+Ax1/3
=PCS+Ax1/4
=PCS+Ax1/5
=PCS+Ax1/6
=PCS+Ax1/7
=PCS+Ax1/8
=PCS+Ax1/9
=PCS+Ax1/10
=PCS+Ax2/1
=PCS+Ax2/2
=PCS+Ax2/3
=PCS+Ax2/4
=PCS+Ax2/5
=PCS+Ax2/6
=PCS+Ax2/7
=PCS+Ax2/8
=PCS+Ax2/9
=PCS+Ax2/10
=PCS+Ax3/1
=PCS+Ax3/2
=PCS+Ax3/3
=PCS+Ax3/4
=PCS+Ax3/5
=PCS+Ax3/6
=PCS+Ax3/7
=PCS+Ax3/8
X
X
X
9876543210
7/21/2019 Wind - Bioenergy
11/159
ContentsPage Page designation
Column x: created autom. but modified manually
Page supplementary field Date User. X
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
18-MAR-2009R. Shaw
18-MAR-2009J. Chacon
Updated section One-Line,PDC,CFC,MCC,TB,GE,SR
C88
next=OneLines/1DOCU
Sh
+
=
of
9
CREV
1.6 xleTYPE
8
104W6321
COMP-PART NO.
COMP-DRW. NO.
7
COMP NO.
Contents 1.5 ESS
COMPONENT
65
Contents
4
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
3
25-APR-2008 G.Stultz
DWBISSUED
DRAWN
GE Energy
2
REVISED BYCHECKED BY
1
7
0
DESCRIPTIONREV
previous
10505000023.Mai.2011DocumentationCenter Box Outputs to Axis Boxes=PCS+PS/7
10505000023.Mai.2011DocumentationCenter Box Hand-Held & Slipring Conns=PCS+PS/6
10505000023.Mai.2011DocumentationCenter Box 400VAC Power Distribution=PCS+PS/5
10505000023.Mai.2011DocumentationCenter Box 690VAC Power Distribution=PCS+PS/4
10505000023.Mai.2011DocumentationPitch System Overview=PCS+PS/3
10505000023.Mai.2011DocumentationCenter Box Modification Information=PCS+PS/2
10505000023.Mai.2011DocumentationCenter Box Cover Page=PCS+PS/1
10505000023.Mai.2011DocumentationBattery Box 3 Axis-to-Battery Connector=PCS+Ax3/10
10505000023.Mai.2011DocumentationBattery Box 3=PCS+Ax3/9
X
=PCS+PS/8 Center Box Ethernet, Light Power, Heater, and Temp Outputs Documentation 23.Mai.2011 105050000
0 1 2 3 4 5 6 7 8 9
7/21/2019 Wind - Bioenergy
12/159
230V / 24VDC
690V / 400V
50 / 60 Hz
Documentation
One Line Drawings
Aratua-1 / 712835
108W661416111805 - 813
N / A
107W5365
One Line Drawings
Project/CMS No.:
WTG No.:WTG Drw No.:
GE Wind Energy 1.6MW
Cover Page
Comp-Part No.:
Comp-Drw. No.:
Comp No.:
Component:
Customer:
Control Voltage:Rated Voltage:
Frequency:
BioEnergy
previous
REV DESCRIPTION
=DOCU/8C HE CK ED BY R EV IS ED BY GE Energy
DRAWN
ISSUED
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY One Lines Cover Page(Indexed)
ENGINEER
DRAWN
CHECKED
ISSUED
25-APR-2008 G.Stultz
DATE
COMPONENT
One Line DrawingsCOMP NO.
SIGNATURE
COMP-DRW. NO.
COMP-PART NO.
GE Energy
107W5365
N / A
TYPE
1.6 xleREV
E
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
of
=
+
Sh
OneLines
2 next
81
DWB
25-APR-2008 G.Stultz
25-APR-2008 A. Ridenour
4-DEC-2007 T. Klodowski
DWB
EUpdated Cover Page, Down Tower Line Up 12-MAR-2009
J. Chacon12-MAR-2009R. Shaw
9876543210
7/21/2019 Wind - Bioenergy
13/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E28
next3OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTOne Lines Modification PageGENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
1DESCRIPTIONREV
previous
Updated Border
date revision change page actual state
3, 4Moved Q3 breaker into PDC panel. Updated Top Box 690VOne-Line to add F7 Surge Suppressor to 690V input.-12/4/2007
03/07/08 AMoved FU1A,B,C fuse to before FB1 & FB2. Changed F6 from 25 to 32A.Deleted sheet 6. Moved sheet 7 to 6 & improved layout.
4, 6,7
Added 2 sheets
6,7
B04/25/08
C09/17/08
Added CBM UnitD11/10/08 12,29,30,31
Updated Cover Page, Down Tower Line UpE03/12/09 1,3
9876543210
7/21/2019 Wind - Bioenergy
14/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E38
next4OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTDown Tower Line UpOne Line Drawing
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
2DESCRIPTIONREV
previous
ROTOR
GEN
PDC - Surge SuppressorPDC - Surge SuppressorPDC - Surge SuppressorPDC - Surge SuppressorEnclosure = PDC/3Enclosure = PDC/3Enclosure = PDC/3Enclosure = PDC/3
CBCCBCCBCCBC
CT4,5,6=CFC/3
Remove Power before servicingRemove Power before servicingRemove Power before servicingRemove Power before servicing
ShuntSHA/B/C2
ShuntSHA/B/C1
LineConverter
DCCap
RotorConverter
StatorStatorStatorStator
Distortion Filter = CFC/6
=CFC/3
400/230 208/120 173/100
MCCMCCMCCMCC X2.1
Stator CurrentFbk.
Converter FilterConverter FilterConverter FilterConverter Filter
Cabinet-Cabinet-Cabinet-Cabinet-CFCCFCCFCCFC
Rotor Over-VoltageContactor
Charge CKT
Power Distribution Cabinet- PDCPower Distribution Cabinet- PDCPower Distribution Cabinet- PDCPower Distribution Cabinet- PDC
=PDC/4
Main BreakerMain BreakerMain BreakerMain BreakerEnclosureEnclosureEnclosureEnclosure
= PDC/4
Q1Q1Q1Q12000A2000A2000A2000AMotor OperatedMotor OperatedMotor OperatedMotor Operated(Converter)(Converter)(Converter)(Converter)
Power Distribution Cabinet- PDCPower Distribution Cabinet- PDCPower Distribution Cabinet- PDCPower Distribution Cabinet- PDC
Power must be removed before servicingPower must be removed before servicingPower must be removed before servicingPower must be removed before servicing
CT1,2,3CT1,2,3CT1,2,3CT1,2,3
690 Y690 Y690 Y690 Y
Main TransformerMain TransformerMain TransformerMain TransformerMV CBMV CBMV CBMV CBLOTOLOTOLOTOLOTOfor Towerfor Towerfor Towerfor Tower
MCCMCCMCCMCC
TB1 TB2
208V or400V3ph
230V, 1ph
120V or 100V, 1ph
Obstruction Lights &Met Mast
Supply Sockets &Motion Lights
Emerg. Lighting,Tower Lighting, FAA Lights, &Nacelle Lighting
3PhHoist
400/230VTop Box
Lights & Sockets configured for 120V or 230V or 100V Distribution.Hoist configured for 208V or 400V
To ConverterTo ConverterTo ConverterTo Converter(Grid Current Fbk.)(Grid Current Fbk.)(Grid Current Fbk.)(Grid Current Fbk.)
Grid Current Fbk.Grid Current Fbk.Grid Current Fbk.Grid Current Fbk.
EnergyEnergyEnergyEnergyMeterMeterMeterMeter(Optional)(Optional)(Optional)(Optional)
X2.1
Grid VoltageFbk.
VoltageTestSocket
230VPower
(Commissioning Back-Feed)
690V to Top Box
PDCPDCPDCPDC
To CBC InternalFans=CBC/6
=MCC/10
230V 1ph
Grid Volts Fbk.
=MCC/10
PDC- Aux Panel
Stator Volts Fbk.
X3.2
SpareDTA- MainCooling Fan
HeatControl
WEMAWEMAWEMAWEMA=MCC/5
230V , 1ph
400/230 V3 ph to DTA
X4.1UPStoTopBox
T3UPS
=MCC/5230V, 1ph
Main Control Cabinet- MCCMain Control Cabinet- MCCMain Control Cabinet- MCCMain Control Cabinet- MCC
HeatersPump
Surge SuppressorStatus Contacts
Q1 (Main Breaker Control)WEOR (K1 Driver and Converter Supply)Converter Charge Ckt Contactor Coil
=PDC/7
=MCC/22
=MCC/5 =MCC/5, =PDC/3
=CBC/6, =PDC/5=CFC/5
=CFC/5, =MCC/15 =MCC/3
=MCC/23=CFC/3
=MCC/23
PDC - AUX PanelPDC - AUX PanelPDC - AUX PanelPDC - AUX Panel
= PDC/3
No Access - Service Entrance
=MCC/10
Aux Panel690V Distribution
=MCC/5
=MCC/10
=MCC/5
=MCC/3 =MCC/3
=MCC/3=MCC/3
=CFC/3
=CFC/4
=PDC/6
=PDC/6
=PDC/6
=PDC/6
=PDC/6
Converter Bridge Cabinet
=PDC/4
X3.4
=MCC/4
=MCC/10
=MCC/12
=PDC/6=PDC/5
=PDC/5
=MCC/5
=MCC/5
24 Vdc
Turbine Controller=MCC/6
(UCSA)
(External Devices)PEN
FB2
100AF4F5F6
FB1
200AF1F2F3
Q2010A
Q1120A
K1
FU1A,B,C355A
(Arc Flash)
L2
=CFC/4
ROVC1,2,3
L1
=CFC/6
ACLFU1,2,3350A
CCR1,2,3CCONT
LFCLFRKDF
T232.5 KVA
Pri:690 VacSec: 400/230V
208/120 or 173/100
Z=4%-6%
FB4
40A
FB3
80A
Q1020A
Q1910A
Q920A
Q1810A
Q126A
Q1320A
Q22/5.416A
GFI I>GFI I>
Q830A
Q24/5.5
6A
Q23/5.416A
Q146A
I>
Q216A
I>
Q5 1A
I>
Q21A
I>
Q61A
I>
Q3
1A
I>
K3K5
K1,K2,K3K13,K14,K15
J9J5
K4
ENV_OK
P14J5A,B,C
/
X5.1X5.1X5.1X3.2 X4.2
/
/
/
/
9876543210
7/21/2019 Wind - Bioenergy
15/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E48
next5OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTTop Box690 V PowerOne Line Drawing
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
3DESCRIPTIONREV
previous
690V from690V from690V from690V from DTA DTA DTA DTA
=CFC/3
690V to690V to690V to690V to PitchPitchPitchPitchSystemSystemSystemSystem
=TB/3 =TB/3
=TB/3
=TB/3
Note: Withshunt tripcapability
=TB/3 =TB/3
ReversingContactor
=TB/3 =TB/3 =TB/3 =TB/3
YawMotor 1
YawMotor 2
YawMotor 3
YawMotor 4
=TB/4
=TB/4
HydraulicPump
=TB/4
=TB/4
=TB/6
=TB/4
=TB/5
GeneratorFan CoolingCircuit 2
=TB/5
=TB/5
GearboxHeatingElements
=TB/5
=TB/6
=TB/4
GeneratorStandbyHeater
GeneratorFan CoolingCircuit 1
=TB/6 =TB/6
Gearbox Oil Cooler -Low Speed
GearboxLubricatingPump - High Speed
GearboxLubricatingPump - Low Speed
Gearbox Oil Cooler -High Speed
=TB/6 =TB/6 =TB/6 =TB/6
ShortingContactor
=TB/6
=TB/3
SurgeSuppressorF2
20A
F1
32A
F632A
Q125A
I>
K1 K2
Q26.3A
I>
Q36.3A
I>
Q46.3A
I>
Q56.3A
I>
Q61.6A
I>
Q710A
I>
Q813A
I>
Q10A,B,C2.5A
I>
Q92.5A
I>
K3 K4 K5 K7A,B,C K6
Q15
10AI>
Q16
10AI>
Q17
10AI>
Q18
10AI>
K10 K12 K11 K13K14
F7
9876543210
7/21/2019 Wind - Bioenergy
16/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E58
next6OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTTop Box400/230 V PowerOne Line Drawing
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
4DESCRIPTIONREV
previous
400/230V400/230V400/230V400/230Vfrom DTAfrom DTAfrom DTAfrom DTA
=CFC/3=CFC/3=CFC/3=CFC/3
SurgeSuppressor
=TB/7
=TB/7
=TB/7
400/230V400/230V400/230V400/230Vto Pitchto Pitchto Pitchto PitchSystemSystemSystemSystem
Slip RingSlip RingSlip RingSlip RingHeaterHeaterHeaterHeater
=TB/7
UPS / HeaterUPS / HeaterUPS / HeaterUPS / Heater ControlControlControlControlPower SupplyPower SupplyPower SupplyPower Supply
=TB/8 =TB/10 =TB/9
Yaw LubeYaw LubeYaw LubeYaw Lube Pump Pump Pump Pump
InternalInternalInternalInternalTB FansTB FansTB FansTB Fans
YawYawYawYawMotorMotorMotorMotorHeatersHeatersHeatersHeaters
=TB/10
Gbx LubeGbx LubeGbx LubeGbx LubePumpPumpPumpPumpHeaterHeaterHeaterHeater
HydraulicHydraulicHydraulicHydraulicPumpPumpPumpPumpHeaterHeaterHeaterHeater
Gbx LubeGbx LubeGbx LubeGbx Lube PumpPumpPumpPumpExchangerExchangerExchangerExchanger
Heat PipeHeat PipeHeat PipeHeat PipeYawYawYawYawMotorMotorMotorMotorBrakesBrakesBrakesBrakes
InternalInternalInternalInternalHeatersHeatersHeatersHeaters
WindWindWindWindVaneVaneVaneVaneHeaterHeaterHeaterHeater
=TB/10
=TB/10 =TB/8 =TB/10
=TB/15
=TB/27
WETBWETBWETBWETB
T2T2T2T2
300 W, 24VDCPower Supply =TB/12
T3T3T3T3
600 W, 24VDCPower Supply =TB/12
230V UPS230V UPS230V UPS230V UPSfrom DTAfrom DTAfrom DTAfrom DTA
=MCC/5
WETBWETBWETBWETB
=TB/7 =TB/7 =TB/8 =TB/9 =TB/9 =TB/9 =TB/9 =TB/10 =TB/8
WETAWETAWETAWETA
=TB/27
F5
Q19A,B,C13A
Q201A
J6
J20
K7
Q223A
Q283A
J6
Q233A
Q243A
J1 J21 J1
K18 K14
P39
K1
J3 J4A,B,C,D
K2 K3 K4
J8 J8 J8 P6 J4A,B,C,D J2A,B,C P19,20,21
K5 K17 K10,11,12A,B
J21 J1 J1,J6,J21 J19
Q253A
Q263A
Q27A,B,C6A
Q323A
T4500VA230V/24v
J18
K21
J17
FU3,4,5
FU6
9876543210
7/21/2019 Wind - Bioenergy
17/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E68
next7OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTControl Hardware One LineGENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
5DESCRIPTIONREV
previous
All circuits shown on=TB/15 unless otherwise noted.Top BoxTop BoxTop BoxTop Box
=MCC/16
All circuits shown on=MCC/8 unless otherwise noted.DTADTADTADTA
WEMA=MCC/11
AEAD WEMA WEMA
grn
WETB WETC WETB
WETB WETB WETB
=MCC/12,13
WETB
WEMA
WEMA AEAD MACC AEAD=MCC/14
18K3
Trip SafetyLoop
18K3
P1-2
K11
WETA CommOK
12 11
S1
/7.1
DTAEstop
X6.1-6
WDOGA
P41C-2 P41C-1
EStop
P41B-2 P12-1
WDOGB
1A 1B
S6
/7.4
Top BoxEstop
12S4
RotorBlocking
Clear
12S1
VibrationSwitch
EXTS7S7PB
8K2Time Delay
Reset
8K1.7
Seal-InRelay
18S2.1External
Stop/Reset
24
23
S2Stop/Reset
DTA
12K2 8K1
P15-2
P1-2
Filter P7-2 P1-3 K9
MFR GridMonitor OK
P7-1 P6-2 P6-1 P1-5
P10-5 13K1
RotorOverspeed
13K1
K1
WETC CommOK
P41B-1 K13
WETB CommOK
P12-2 P13-1 P14-1P13-2 P14-2 12K3
/7.8Hub EStop
3
4
S7
Stop/ResetTop Box
EstHub
P10-1
P15-1P16-1
12K2Safety Loop to
Pitch andBrake Valves
P16-2
P10-2
P10-3
P1-1
8K1Safety Loop
Closed
P6-10
P1-3
P6-9
X4.1-30
3=TB/29
1
3
X4.1-28
1=TB/29
X6.1-4
X4.1-28
2
=TB/29
4
X6.1-3
X4.1-29
1=TB/29
3
X6.1-2
8K1.7
Seal-InRelay
DIN9DigitalInput
HardwareDrop-Out
Delay
AEAD-K1Q1 UV
Trip
AEAD-K2Synchronization
SwitchPilot Relay
P7-5
P7-6
TB2-17
TB2-18
J1 J1
P24_SFTYP24
PCOM
PCOM
9876543210
7/21/2019 Wind - Bioenergy
18/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E78
next8OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTControl Hardware One LineGENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
6DESCRIPTIONREV
previous
DTADTADTADTA
WEMAWETBWETB
Top BoxTop BoxTop BoxTop BoxDTADTADTADTA
WEMA
WEMA
WETB WETC
WETB
AEPC AEPC AEPC WETB
Top BoxTop BoxTop BoxTop Box SlipringSlipringSlipringSlipring Pitch System - Center BoxPitch System - Center BoxPitch System - Center BoxPitch System - Center Box SlipringSlipringSlipringSlipring Top BoxTop BoxTop BoxTop Box
Note: P24SW powers mostcontact outputs in the Top Box.
All circuits shown on=MCC/8
All circuits shown on=MCC/8 All circuits shown on
=TB/15 unless otherwise noted.
WETB=TB/13
All circuits shown on=SR/4
All circuits shown on=PSCB/6
All circuits shown on=SR/4
All circuits shown on=TB/17
All circuits shown on=TB/17 unless otherwise noted.
JX-C1X4.1-14
5=TB/296
JX-C4
12K3/6.3
.3
Hub EStop
P9-4SR12TB1-6
21
Manual = OpenAuto = Closed
Man/AutoSelector Switch
J6-8
ePALMEstop
J6-5J6-21 2
HubEstop
J6-1TB1-1SR5J16-1
22 21
S1
/6.3
DTAEstop -EstHub
1B 2B
S6
Top BoxEstop
/6.4
K13
WETB CommOK
K1
WETC CommOK
K11
WETA CommOK
13K3
Contactor DriverEnable
.7
J16-2
P6-4 P6-3 P1-4 P10-4 12K3
.8Hub EStop
P12-3 P12-4
-WDOGB
P41B-3 P41C-3 P41C-4 P41B-4 P10-6 P1-6
-EStop -WDOGA
X6.1-7 X4.1-29
4=TB/292
X4.1-30
2=TB/29
4
X6.1-1
13K3
.7
Contactor DriverEnable
P24_SFTY
PCOM
PP24
PCOM
P24 P24SW
9876543210
7/21/2019 Wind - Bioenergy
19/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
12-MAR-2009R. Shaw
12-MAR-2009J. Chacon
Updated Cover Page, Down Tower Line Up
E88
next=PDC/1OneLines
Sh
+
=
ofEREV
1.6 xleTYPE
107W5365
COMP-PART NO.
COMP-DRW. NO.COMP NO.
One Line Drawings
COMPONENTControl Hardware One LineGENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
25-APR-7008 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
7DESCRIPTIONREV
previous
AEAD
8
6
4
2
5
3
1
green
N-Tron
N-Tron
N-Tron
N-Tron
509FX
509FX
509FX
509FX
Enet1
Rcopperconnections
UCSAUCSAUCSAUCSA
S
T
=AXS3/4-7=AXS2/4-7=AXS1/4-7
=AXS3/7=AXS2/7=AXS1/7
=TB/13-15,18-22=TB/7-10,13-17
=TB/13
=TB/13-15,23-28
=MCC/22 =MCC/19
=MCC/21
=MCC/20
=MCC/21
=MCC/20
=MCC/11=MCC/17,18
=MCC/12-16
I/O Net - Fiber
=MCC/4-10
Nacelle
Hub
Down-TowerAssembly
Discrete ComponentsDigital InputsContactors
Environmental Control
SerialSerial
PT100 Temperature4-20mA Analog Ins
Prox Switches
Wind Vane /Anemometer
Vibration Sensors
Rotor ConverterIGBTs
Line ConverterIGBTs
Power Controls,Contactors,
Voltage/CurrentSensing
I/O Net
I/O Net
Discrete ComponentsDigital InputsContactors
Environmental Control
I/O Net
J4
Enet2Enet2Enet2Enet2 A4A4A4A4
7
green
1
3
5
fiberconnections
2
4
6
fiberconnections
N-Tron
N-Tron
N-Tron
N-Tron
508FX2
508FX2
508FX2
508FX2
copperconnections
Enet1Enet1Enet1Enet1 A3A3A3A3
USBCOM
Enet2
J4
J4J4J4
J4
N-Tron
N-Tron
N-Tron
N-Tron
508TX-A
508TX-A
508TX-A
508TX-A
6
4
Enet2Enet2Enet2Enet2 ESESESES
2
5
3
1
7
green
copperconnections
8
N-Tron
N-Tron
N-Tron
N-Tron
509FX-A
509FX-A
509FX-A
509FX-A
green
7
1
3
5
2
4
6
8
copperconnections
fiberconnections
Enet2Enet2Enet2Enet2 A1A1A1A1
=MCC/6
=PSCB/8
=TB/13
RJ45
Top Box
WETCWETB
BPPB
WETA
BPPB
AEPA
BPPB
AEPA
BPPB
AEPA
Pitch Drives
AEBM
AEBM
WEOR AEPS
AEBI 2
AEBI 1
AEAA
BPPB
MACC
Power Converter
BPPB
WEMA
Main Control
230 VAC
DC Bus
0 1 2 3 4 5 6 7 8 9
7/21/2019 Wind - Bioenergy
20/159
BioEnergy
Documentation
Power Distribution Cabinet
107W5379P001
107W4611
Power Distribution Cabinet
GE Wind Energy 1.6MW
Comp-Part No.:
Comp-Drw. No.:
Comp No.:
Component:
Kunde /Customer:
previous
REV DESCRIPTION
=OneLines/8C HE CK ED BY R EV IS ED BY GE Energy
DRAWN
ISSUED
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY Power Distribution CabinetCover Page
ENGINEER
DRAWN
CHECKED
ISSUED
26-MAR-2009 G. Stultz
DATE
COMPONENT
Power Distribution CabinetCOMP NO.
SIGNATURE
COMP-DRW. NO.
COMP-PART NO.
GE Energy
107W4611
107W5379P001
TYPE
1.6 xleREV
B
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
of
=
+
Sh
PDC
2 next
71
DWB
26-MAR-2009 G. Stultz
26-MAR-2009 A. Klodowski
26-MAR-2009 A. Klodowski
DWB
BUpdated Converter 03-NOV-2009
J. Curtis03-NOV-2009R. Shaw
Connection:Connection:Connection:Connection:
Nominal Voltage (3PH):Nominal Voltage (3PH):Nominal Voltage (3PH):Nominal Voltage (3PH):
Frequency:Frequency:Frequency:Frequency: 50/60 Hz
690 V
1430Current (A RMS):Current (A RMS):Current (A RMS):Current (A RMS):
MAINTRANSFORMER
GENSTATOR
690 V
50/60 Hz
1400
690 V
50/60 Hz
GENROTOR
640 MAX
MAX Symmetrical Short Circuit Current(Main Transformer Conn): 26 kA RMS, 690VACOperating Temp: -30C to 45C, 85% CUR @ 50C MAXSoftware IPN: DFIGe-1500-5060-A
Control using Doubly Fed Induction GeneratorControl using Doubly Fed Induction GeneratorControl using Doubly Fed Induction GeneratorControl using Doubly Fed Induction Generator
7/21/2019 Wind - Bioenergy
21/159
9876543210
CT1 4.0
7/21/2019 Wind - Bioenergy
22/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B37
next4PDC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTPower Distribution CabinetTVSS
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
2DESCRIPTIONREV
previous
shortest connectionto PE busbar
BUSBAR JUMPER
BUSBAR JUMPER
BUSBAR JUMPER
s2
Enclosed DevicesPower must beremoved beforeservicing
s1
s2 s1
BUSBAR
BUSBAR
BUSBAR
shortest connectionto PE busbar
BUSBAR
BUSBAR
BUSBAR
BUSBAR
Surge SuppressorCircuuits
s1s2690VfromMainTransformer
-F5.8
SolidState
U -F6.8
SolidState
U
-PEN
P2 P1-CT3
1500:510VA, 0.5%
43
44
-Q16.7
12
11
-F4.5
12
11
-F5.5
PEN
L3
L2
L1
43
44
-Q15.6
L1
T1
L2
T2
L3
T3
-FB1200A
L1
T1
L2
T2
L3
T3
-FB2100A
1
2
3
4
5
6
-Q16.8
.16-.25Afuse
monitor I>>I>>I>>
1
2
3
4
5
6
-Q15.7
.16-.25Afuse
monitor I>>I>>I>>
1
2
-F2Spark
Gap
-PEN
1
2
-F1Spark
Gap
1
2
-F3Spark
Gap
12
11
-F6.5
L3
T3
-FU1C355A690V
L2
T2
-FU1B355A690V
L1
T1
-FU1A355A690V
-F4.8
SolidState
U
P2 P1-CT1
1500:510VA, 0.5% P2 P1
-CT2
1500:510VA, 0.5%
L1B4.0
CT3-k
/
=MCC/12
.0
CT3-l
/
=
MCC/10
.3CT2-k
/
=MCC/12
.0
CT2-l
/
=
MCC/10
.3CT1-k
/
=MCC/12
.0
CT1-l
/
=
MCC/10
.3
WEMAP14-1=MCC/5.2
DTAK2A1=MCC/5.2
L2B4.0
L36.0
L26.0
L16.0
PEN6.0
L3B4.0
9876543210
7/21/2019 Wind - Bioenergy
23/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B47
next5PDC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTPower Distribution CabinetMain Breakerand Synch Contactor
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
3DESCRIPTIONREV
previous
L3A
(Other Devices -See One Lines)
Stator VoltageFeedback to AEAA
L1A
L2A
L1
T1
L2
T2
L3
T3
-Q60.63-1A
(1A)
I>>I>>I>>
L2
T3
T1
L3
T2
L1
-Q12000AMotor
Operated
L1T1
-K1/7.6
L2T2
L3T3
-PDC_AUX
AEAAP2-L
2
/
=MCC/18
.2
AEAAP4-L
3
/
=MCC/18
.3
L1D=CFC/5.0
L2D=CFC/5.0
L3D=CFC/5.0
CONVL3A
/
5.0
AEAAP1-L
1
/
=MCC/18
.1
L1B3.9
L2B3.9
L3B3.9
CONVL1A
/
5.0
CONVL2A
/
5.0
AEAAP3-L
2
/
=MCC/18
.3
9876543210
7/21/2019 Wind - Bioenergy
24/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B57
next6PDC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTPower Distribution CabinetConv Line Fuses, DCBus Charger, & Line Filter
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
4DESCRIPTIONREV
previous
350A690V
L2
T2
2
1
-CCR250 Ohms
500W
L3
T3
2
1
-CCR350 Ohms
500W
1
2
-HTR7250W
1
2
-HTR8250W
1 2
-ACLFU3
1 2
-ACLFU2
1 2-ACLFU1
L1
T1
CCONT=MCC/5.4
2
1
-CCR150 Ohms
500W
PDCAUX-Q
5-T
3/6.9
HTR7-1/=
CFC/5
.9
HTR7-2
/
=CFC/5
.9
ACLFU3-2=CFC/6.0
ACLFU2-2=CFC/6.0
ACLFU1-2
=CFC/6.0
CONVL3A4.4
CONVL2A4.4
CONVL1A
4.3
PDCAUX-Q
5-T
1/6.8
PDCAUX-Q
5-T
2/6.8
9876543210
7/21/2019 Wind - Bioenergy
25/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B67
next7PDC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTPower Distribution Cabinet690V Distribution
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
5DESCRIPTIONREV
previous
Bus Jumper
Bus Jumper
Optional Energy Meter Charge Control PowerVoltage Feedback toFrequency Converter forgrid monitor Function(AEAD)
T2 Feed ForAux/Control Power400/230V208/120V173/100V
Bus Jumper
Bus Jumper
Bus Jumper
690V to Top Box
Bus Jumper
L1
T1
L2
T2
L3
T3
-Q30.63-1A
(1A)
I>>I>>I>>
L1
T1
L2
T2
L3
T3
-FB440A
NH 0
PEN
L1
T1
L2
T2
L3
T3
-Q50.63-1A
(1A)
I>>I>>I>>
L1
T1
L2
T2
L3
T3
-Q20.63-1A
(1A)
I>>I>>I>>
L1
T1
L2
T2
L3
T3
-FB380A
-PDC_AUX
T2-H
1
/
=CFC/3
.0
T2-H
2
/
=CFC/3
.0
T2-H
3
/
=CFC/3
.0
PDCAUX-F
B3-T
1
/
=MCC/10
.7
PDCAUX-F
B3-T
2
/
=MCC/10
.8
PDCAUX-Q
5-T
1
/
5.2
PDCAUX-F
B3-T
3
/
=MCC/10
.8
PEN3.9
L33.9
AEADP3
/
=MCC/16
.5
AEADP5
/
=MCC/16
.5
PDCAUX-Q
3-T
1
/
=MCC/10
.5
L23.9
L13.9
PDCAUX-Q
3-T
2
/
=MCC/10
.5
PDCAUX-Q
3-T
3
/
=MCC/10
.6
PDCAUX-Q
5-T
3
/
5.3
PDCAUX-Q
5-T
2
/
5.3
AEADP7
/
=MCC/16
.5
9876543210
7/21/2019 Wind - Bioenergy
26/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B77
next=CFC/1PDC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTPower Distribution CabinetMain Breakerand Synch Contactor
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
6DESCRIPTIONREV
previous
To
talsurge
R:
19
.5Ohm
Ho
lding
R:
920Ohm
Lho
lding=.4
Hy
Pickup
time:
80msec
Opera
tingvo
ltage:
85-1
10%
Dropou
tvo
ltage:
20-4
0%
N
norma
lvo
ltage=~
205Vdc
D2 84
-Q1BELL ALARM
81
-K1/4.5
Contactor LC1F780Internal Coil Circuit
A1 A2
-Q1
-Q1UV
Coil24VDC
B1 B1'
-Q1Motor
Operation230VAC
B2 B2'
A1
-Q1Closing
Coil230VAC
A2
D1
DTAQ1N
=MCC/5
.3
DTAQ1B2
=MCC/5
.3
AEADK6NO
=MCC/15
.3
AEADK1COM
=M
CC/14
.2
AEA
DP11
=M
CC/14
.2
AEADTB1-7/=
MCC/13
.3
AEADTB1-8/=
MCC/13
.4
DTAK1
-A1
/
=MCC/22
.9
DTAK1
-A2
/
=MCC/22
.9
AEADK6COM
=MCC/15
.3
0 1 2 3 4 5 6 7 8 9
7/21/2019 Wind - Bioenergy
27/159
BioEnergy
Documentation
Converter Filter Cabinet
107W5379P001
107W4611
Converter Filter Cabinet
GE Wind Energy 1.6MW
Comp-Part No.:
Comp-Drw. No.:
Comp No.:
Component:
Kunde /Customer:
previous
REV DESCRIPTION
=PDC/7C HE CK ED BY R EV IS ED BY GE Energy
DRAWN
ISSUED
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY Converter Filter CabinetCover page
ENGINEER
DRAWN
CHECKED
ISSUED
26-MAR-2009 G. Stultz
DATE
COMPONENT
Converter Filter CabinetCOMP NO.
SIGNATURE
COMP-DRW. NO.
COMP-PART NO.
GE Energy
107W4611
107W5379P001
TYPE
1.6 xleREV
B
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
of
=
+
Sh
CFC
2 next
61
DWB
26-MAR-2009 G. Stultz
26-MAR-2009 A. Klodowski
26-MAR-2009 A. Klodowski
DWB
BUodated Converter 03-NOV-2009
J. Curtis03-NOV-2009R. Shaw
Current (A RMS):Current (A RMS):Current (A RMS):Current (A RMS):
690 V
50/60 HzFrequency:Frequency:Frequency:Frequency:
Nominal Voltage (3PH):Nominal Voltage (3PH):Nominal Voltage (3PH):Nominal Voltage (3PH):
Connection:Connection:Connection:Connection:MAIN
TRANSFORMER
1430
GENSTATOR
690 V
50/60 Hz
1400
690 V
50/60 Hz
GENROTOR
640 MAX
MAX Symmetrical Short Circuit Current(Main Transformer Conn): 26 kA RMS, 690VACOperating Temp: -30C to 45C, 85% CUR @ 50C MAXSoftware IPN: DFIGe-1500-5060-A
Control using Doubly Fed Induction GeneratorControl using Doubly Fed Induction GeneratorControl using Doubly Fed Induction GeneratorControl using Doubly Fed Induction Generator
9876543210
7/21/2019 Wind - Bioenergy
28/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B26
next3CFC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTConverter Filter CabinetModification Page
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
1DESCRIPTIONREV
previous
4, 5
3, 5, 24
Converter Update - Added option for extra Rotor cable connections. Added option for extra Stator cable connections.
B11/03/09
07/23/09 A MCC Update - Removed -A5, -K3, -Q14, Changed Q21 Amps,Added Jumper UPSN-J1, Removed -A2-BP - UPS Bypass
date actual staterevision change page
03/26/09 - New Release
9876543210
7/21/2019 Wind - Bioenergy
29/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B36
next4CFC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTConverter Filter CabinetControl PowerDistribution 1
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
2DESCRIPTIONREV
previous
L1/L2 Shelf
T2 ShelfN
230L1
230L2
230L3
400V Tower Hoist Connections
230L1
230L2
230L3
N
400V - 3 phase (230V line - neutral)
690 V32.5 KVA Transformer@ 40 degrees C
T2 208V - 3 phase (120V line - neutral) 173V - 3 phase (100V line - neutral)
OptionalConnectionfor 400Vac
(Other Devices -See One Lines)
=MCC/7.2
X9
-PEN
Chassis
-PDC_AUX
-MCC
1
2
3
4
5
6
-Q1320A
-X3.2 1 2 3
1(1)-X3.3
1(2)
4
-T2
5 -PEN
X1 X2
1
2
3
4
5
6
-Q830A
X3 X1 X2 X3 X0
H1
X0
H2 H3
X4 X5 X6 X7 X8
DTA400PE
/
=TB/7
.0
Q8-2
/
=MCC/24
.3
Q8-4
/
=MCC/24
.3
Q8-6
/
=MCC/24
.3
PDCAUX-Q
18-1
/
=MCC/23
.0
PDCAUX-Q
19-1
/
=MCC/23
.0
T2-H3/=PDC/6.4
PDCAUX-Q
20-1
/
=MCC/23
.0
PDCAUX-Q
9-1
/
=MCC/23
.0 P
DCAUX-Q
10-1
/
=MCC/23
.0
PDCAUX-Q
11-1
/
=MCC/23
.0
PDCAUX-Q12-L1=MCC/23.0
PDCAUX-Q12-L2=MCC/23.0
PDCAUX-Q12-L3=MCC/23.0
T2-X1/=MCC/23.0
T2-X2/=MCC/23.0
T2-X3/=MCC/23.0
T2-H2/=PDC/6.4
T2-H1/=PDC/6.4
DTA400T1
/
=TB/7
.0
DTA400T2
/
=TB/7
.0
DTA400T3
/
=TB/7
.0
DTA400N
/
=TB/7
.0
9876543210
TOR
Gnd 1 32
.25.5
.3
5.5.15.
525.
4.35
.415.4
.15.3
.25.3
.35.3
7/21/2019 Wind - Bioenergy
30/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B46
next5CFC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTConverter Filter CabinetROV ContactorsRtr Conns and Reactor
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
3DESCRIPTIONREV
previous
ROTOR
Standard Offering (Busbar)
1 Cable per phase to busbar in towerDLO 646 Kcmil.Ground Cables - DLO 4/0 AWG.
3 Cables per phase - no busbar95mm.Ground Cables - 95mm.
Option 1 (Tower Cables)
+
+
+
-
-
-
ROT G
OPTION 1OPTION 1
*
*OPTION 1
* *
2
3 4-PEN
B1
B2
C1
C2
A1
A2
-L225uH750A
-ROVC2
-ROVC1
-ROVC3
21
0.5u
F
22Ohms
0.5
uF
22Ohms
.4
21
0.5
uF
22Ohms
43
3 4
1
M.6
=GE/
M.6
=GE/
M.6
=GE/
L.6.
=GE/5
L.6.
=GE/5
L.6.
=GE/5
CONV-L
2-A
1
=CBC/5
.3
CONV-L
2-B
1
=CBC/5
.7
CONV-L
2-C
1
=CBC/5
.8 ROVC3-1
=MCC/14
.8
ROVC3-2
=MCC/14
.8
1PE
.6.2
=GE/5
.2 K.6.
=GE/5
K.6.
=GE/5
K.6.
=GE/5
L1 Chassis6.7
9876543210
STATOR
P2 P1-CT4
L1D=PDC/4.9
7/21/2019 Wind - Bioenergy
31/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B56
next6CFC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTConverter Filter CabinetStator Current FeedbackCTs and Heaters
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
4DESCRIPTIONREV
previous
4 Cables per phase - no busbar240mm.Ground Cables - 240mm.
Option 1 (Tower Cables)
3 Cables per phase to busbar in towerDLO 444 Kcmil.Ground Cables - DLO 4/0 AWG.
Standard Offering (Busbar)
STATOR
*
OPTION 1
OPTION 1
OPTION 1
*
*
*
s1
0.5ufd100
s2
s2 s1
s2
s1
32
1
2
3
GNDQty 2 -4/0 Cables
-PEN(on PDC side)
-PEN(on MCC side)
-PAS0 1
-GND
-PEN
1 4
-M1230 Vac 1 PH
60 Hz11 A
PUMP MOTOR
1~M
-OTKLIXON
1
2
-HTR11500WCoolant Heater
-PEN
1
2
-HTR5250W
1
2
-HTR6250W
P2 P1-CT6
1500:15VA, 0.5%
P2 P1
1500:15VA, 0.5%
P2 P1-CT5
1500:15VA, 0.5%
-J
-PEN
PUMP-M1-4=MCC/24.3
HTR5-1/=
MCC/4
.8
1L2.6.2/ =GE/4.2
1L2.6.3/ =GE/4.2
1PE.6.1/ =GE/4.4
HTR5-2
/
=MCC/24
.6
HTR7-1=PDC/5.6
HTR7-2=PDC/5.6
1L3.6.1/ =GE/4.3
1L3.6.2/ =GE/4.3
1L3.6.3/ =GE/4.3
1L1.6.2/ =GE/4.1
1L1.6.3/ =GE/4.1
L2D=PDC/4.9
1L2.6.1/ =GE/4.2
1L3.6.4/ =GE/4.4
1L2.6.4/ =GE/4.2
1L1.6.4/ =GE/4.1
1L1.6.1/ =GE/4.1
L3D=PDC/4.9
AEAATB3-6
6
/
=MCC/17
.3
AEAATB3-6
5
/
=MCC/17
.3
AEAATB3-6
4
/
=MCC/17
.2
AEAATB3-6
3
/
=MCC/17
.2
AEAATB3-6
2
/
=MCC/17
.1
AEAATB3-6
1
/
=MCC/17
.1
WEMAK15-C
OM/=
MCC/4
.2
WEMAK14-C
OM/=
MCC/4
.2
HTR1-2=MCC/24.6
9876543210
VAR
50Hz
7/21/2019 Wind - Bioenergy
32/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B66
next=MCC/1CFC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTConverter Filter CabinetLine Filter
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
5DESCRIPTIONREV
previous
L1
T1=MCC/15.2
KDFL2
T2
L3
T3
0.0
27Ohmseach
65KVAR
600V60Hz
NOMINALCAP.
VALUE=160uF
NOMINALRES.
VALUE=100K
71.8
KV
690V5
ELEMENTSS
TAMPED
WITHPSG
104
L1/L2 shelf
-LFC
2
1-LFR1C
2
1-LFR1A
1
2
1 -LFR1D
2
1 -LFR1B
2
1-LFR2C
2
1-LFR2A
2
2
1 -LFR2D
2
1 -LFR2B
2
1 -LFR3D
2
1-LFR3A
3
2
1-LFR3C
2
1 -LFR3B
A2
A1
B2
B1
C2
C1
-L1
150
H375A
chassis
ACLFU3-2=PDC/5.9
ACLFU2-2=PDC/5.9
ACLFU1-2
=PDC/5.9
CONV-L
1-A
1/=
CBC/3
.8
CONV-L
1-B
1/=
CBC/3
.8
CONV-L
1-C
1/=
CBC/3
.8
L1 Chassis4.2
0 1 2 3 4 5 6 7 8 9
7/21/2019 Wind - Bioenergy
33/159
BioEnergy
Documentation
Main Control Cabinet
107W5379P001
107W4611
Main Control Cabinet
GE Wind Energy 1.6MW
Comp-Part No.:
Comp-Drw. No.:
Comp No.:
Component:
Kunde /Customer:
previous
REV DESCRIPTION
=CFC/6C HE CK ED BY R EV IS ED BY GE Energy
DRAWN
ISSUED
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
C
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY Main Control CabinetCover Page
ENGINEER
DRAWN
CHECKED
ISSUED
26-MAR-2009 G. Stultz
DATE
COMPONENT
Main Control CabinetCOMP NO.
SIGNATURE
COMP-DRW. NO.
COMP-PART NO.
GE Energy
107W4611
107W5379P001
TYPE
1.6 xleREV
B
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
of
=
+
Sh
MCC
2 next
251
DWB
26-MAR-2009 G. Stultz
26-MAR-2009 A. Klodowski
26-MAR-2009 A. Klodowski
DWB
BUodated Converter 03-NOV-2009
J. Curtis03-NOV-2009R. Shaw
Current (A RMS):Current (A RMS):Current (A RMS):Current (A RMS):
690 V
50/60 HzFrequency:Frequency:Frequency:Frequency:
Nominal Voltage (3PH):Nominal Voltage (3PH):Nominal Voltage (3PH):Nominal Voltage (3PH):
Connection:Connection:Connection:Connection:MAIN
TRANSFORMER
1430
GENSTATOR
690 V
50/60 Hz
1400
690 V
50/60 Hz
GENROTOR
640 MAX
MAX Symmetrical Short Circuit Current(Main Transformer Conn): 26 kA RMS, 690VACOperating Temp: -30C to 45C, 85% CUR @ 50C MAXSoftware IPN: DFIGe-1500-5060-A
Control using Doubly Fed Induction GeneratorControl using Doubly Fed Induction GeneratorControl using Doubly Fed Induction GeneratorControl using Doubly Fed Induction Generator
9876543210
7/21/2019 Wind - Bioenergy
34/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B2
25
next3MCC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTMain Control CabinetModification Page
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
1DESCRIPTIONREV
previous
4, 5
3, 5, 24
Converter Update - Added option for extra Rotor cable connections. Added option for extra Stator cable connections.
B
page actual statechangerevision
Removed -A5, -K3, -Q14, Changed Q21 Amps,Added Jumper UPSN-J1, Removed -A2-BP - UPS Bypass
A07/23/09
11/03/09
date
03/26/09 - New Release
9876543210
Q14 L1/24 3
7/21/2019 Wind - Bioenergy
35/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B3
25
next4MCC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTMain Control CabinetFans
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
2DESCRIPTIONREV
previous
ChassisSpare
Sup
bkblbn-W1
-X3.4 1(2)
-X3.4 1(1)
-W1
1
2
-Fan1.5
(OT Switch)
A1
A2
-K5T1 .5
T2 .5
T3 .6-PEN
T2T1
-K5.7
-PEN
9(2)
9(1)
8(2)
8(1)
7(2)
7(1)
-X3.26(2)
-X3.26(1)
wh
wh
wh
-X3.1 21(2)
-X3.1 21(1)
T3
L1 L2 L3
-Q212.5-4A(2.5A)
I>>I>>I>>
L1 L2 L3-Fan1Main DTA
Ventilator Fan400vac 3 ph50 Hz 2.3A60 Hz 2.5A
M3~
2(1)
-W2
-W1
2(2) -W1
-X3.4 6(1)
-X3.4 6(2)
-X3.4 5(2)
-X3.4 5(1)
-X3.1 22(2)
-X3.1 22(1)
gr/bk-W2-W1
3(2)
3(1)
bkrd wh/bk bl
ye/gr
-W2
orgyrd
AEADK8COM15.8
AEADK8NO
15.7
K5-A224.6
Q14-L3/24.3
Q14-L2/24.3
Q14-L1/24.3
9876543210
7/21/2019 Wind - Bioenergy
36/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B4
25
next5MCC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTMain Control CabinetCold Weather Heating
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
3DESCRIPTIONREV
previous
HTR3
HTR5, HTR6, HTR7, HTR8(CFC, PDC Heaters)
HTR4HTR2HTR1(Coolant Heater)
(PUMP)
L3, 230VACL3230Vac
L1230Vac
L2230Vac
L2230Vac
L2230Vac
(MCC, CBC, Air Heaters)
-WEMA
J10-1
J10-3
K15-NO
K15-COM
K14-NO
K14-COM K1-COM
K1-NO
K2-COM
K2-NO K3-NO
K3-COM
-WEMAK13-NC
K13-COM
-K14-K15 -K13-K1 -K2 -K3
WEMA-K
14-N
O
24
.6
WEMA-K
15-N
O
24
.3
AEADK7NO/15.5
AEADK7COM/15.5
WEMAK15-C
OM
/
=CFC/5
.5
WEMAK14-C
OM
/
=CFC/5
.5
W
EMAK1-C
OM
/
=CBC/6
.5W
EMAK2-C
OM
/
=CBC/6
.7W
EMAK3-C
OM
/
=CBC/6
.9
WEMA-K
1-N
O
24
.6
WEMA-K
2-N
O
24
.6
WEMA-K
3-N
O
24
.6
HTR5-1
/
=CFC/5
.8
WEMA-K
13-N
C
24
.6
9876543210
From PDC TVSSProtective Switches
L1230Vac
Neut.
T1L1 =PDC/5.24.6
7/21/2019 Wind - Bioenergy
37/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B5
25
next6MCC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTMain Control CabinetUPS 24V Power
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
4DESCRIPTIONREV
previous
J83
1
red
wht
grn
blk
L1 N
230VAC via UPS to Top Box
Q1Q1Q1Q1 WEOR WEORWEORWEOR
Sup
ENV OK
230Vac
230Vac
Neutral
K4 Relay (ENV OK) is turned on when any of the following conditions are met:-MCC cabinet temperature> 5 deg C for a 70 minutes heat-soak delay time-MCC cabinet temperature> 45 deg C for 10 minutes-Pushing and holding S2 (Stop/Reset Pushbutton- WEMA Din29) for 5 seconds
3
1
J7
Input plug
Output plug
Sup
-J5C-1-
-J5C-2-
-J5C-3-
-J5-1-
-J5-3-
-PEN
L
N
PE UPSL
1
2
3
4
-Q2316A
-X4.1 1(1)
-X4.1 1(2)
2(1)
2(2)
UPSN
3(1)
3(2)
4(1)
4(2)
-PEN
-X4.1 5(1)
-X4.1 5(2)
-T324V DC
12A
PowerSupplyvia UPS
L
N
-PEN
(+)
(-)
-WEMA
J7-1
-WEMA
1
2
-Q2216A
-J9-1-
-J9-4-
-P14-1-
-P14-4-
-J5A-1-
-J5A-2-
-J5A-3-
-J5B-1-
-J5B-2-
-J5B-3-
J7-2
J7-3
J7-4
(+)
(-)
-K4-A2
230VACUPS
-UPSNOT
OK
-LOWBATTERY
A1
A2
-K2
4344 /7.0
A2
A1
-CCONT
/
T2L2 =PDC/5.3
T3L3 =PDC/5.3
21
22
-KDF/15.2
UPSN-J1
24.3
WEMA-J
9-4/24
Q22-1/24
.3
DTAQ1B2/=
PDC/7
.1
DTAQ1N/=
PDC/7
.0
WEMA-J
5B-L
22
.2
WEMA-J
5B-N
22
.2
DTA 230 UPS PE/ =TB/29.9
DTA230UPSN
=TB/29.9
DTA230UPSL
=TB/29.9
A2-J7-3/ 7.1
A2-J7-1/ 7.1
A2-J8-1/ 7.2
A2-J8-3/ 7.2
DTAK2A1
=PDC/3
.9
WEMAP14-1
=PDC/3
.7
9876543210
WEMA
-A3 IN2
7/21/2019 Wind - Bioenergy
38/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT 2009 GENERAL ELECTRIC COMPANYC
03-NOV-2009R. Shaw
03-NOV-2009J. Curtis
Updated Converter
B6
25
next7MCC
Sh
+
=
ofBREV
1.6 xleTYPE
107W5379P001
107W4611
COMP-PART NO.
COMP-DRW. NO.COMP NO.
Downtower Assembly
COMPONENTMain Control CabinetEthernet Switches and UCSA
GENERAL ELECTRIC COMPANYWIND ENERGY TECHNOLOGY
26-MAR-2009 G. Stultz
DWBISSUED
DRAWN
GE EnergyREVISED BYCHECKED BY
5DESCRIPTIONREV
previous
ENET Switch 1SCADA
ENET Switch 2IONET
FiberOptic
FiberOptic
ENETRJ45
ENETRJ45
FIELD SERVICECONNECTIONSCADA
Uptowerto
TOPBOX
EXTERNALSOURCE24VDC
EXTERNALSOURCE24VDC
"PLANT CUTS IN"EXTERNALCONTROL
OPTIONAL FIELDCONNECTIONS
Chassis
OrderableMo
dule(WEMA&BPPB)=IS215WEMAH1A
OrderableMo
dule(WEMA&BPPB)=IS215WEMAH1A
OrderableMo
dule(WEMA&BPPB)=IS215WEMAH1A
OrderableMo
dule(WEMA&BPPB)=IS215WEMAH1A
Din 15ExternalStop
Din 14LockingMains On
+24Vdc
+24Vdc
+24Vdc
COM
COM
COM
1
8(2)
8(1)
5
9(2)
9(1)
6
10(2)
10(1)
-K6DO 06
-WEMA
P2-1
P2-3
P5-1
P5-3
P2-2
P2-4
J4
-FE
-FE
-FE
-FE
A3
-UCSA
-A4
V1(+)
V1(-)
P12-1
P12-3
V1(+)
V1(-)
-PEN
IN2
OUT2
IN
OUT
3
1
2
Enet1
R
IN
OUT
1
2
3
-WEMA
-X6.1 11(2)
-X6.1 11(1)
-TB4 4
- +
-S4
12(2)
12(1)
3
13(2)
13(1)
2
- +
-S5
14(2)
14(1)
MACC_BPPBJ4/ 11.4
Fiber In/ =TB/13.2
Fiber Out/ =TB/13.2
Top Box- Enet/ =TB/11.0
9876543210
7/21/2019 Wind - Bioenergy
39/159
PROPRIETARY INFORMATION-THIS DOCUMENT CONTAINSPROPRIETARY INFORMATION OF GENERAL ELECTRICCOMPANY AND MAY NOT BE USED OR DISCLOSED TOOTHERS, EXCEPT WITH THE WRITTEN PERMISSION OFGENERAL ELECTRIC COMPANY.
COPYRIGHT