Post on 07-Mar-2018
(UK 2723)
V(0)a
United Kingdom of Great Britain and Northern Ireland
Certificate of EC type-approval of a
measuring instrument
Number: UK 2723 Revision 6 issued by the Secretary for Business, Innovation & Skills
Notified Body Number 0126
In accordance with the requirements of the Non-automatic Weighing Instruments
Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council
Directive 2009/23/EC, this certificate of EC type-approval has been issued to:
Avery Weigh-Tronix Ltd
Foundry Lane
Smethwick
West Midlands
B66 2LP
United Kingdom
in respect of a non-automatic weighing instrument, utilising the Avery Weigh-Tronix
E1005/E1010 series indicating devices (Test certificate GB-1179) connected to a platform.
n ≤ 10000 for Class III instruments with single interval
n ≤ 5000 for Class III instruments with multi-interval operation, maximum
two partial weighing ranges.
n ≤ 1000 for Class IIII instruments with single interval.
The necessary data (principal characteristics, alterations, securing, functioning etc) for
identification purposes and conditions (when applicable) are set out in the descriptive annex
to this certificate.
This Revision replaces earlier versions of the certificate.
Signatory: G. Glas
for Chief Executive
National Weights & Measures Laboratory
(Part of National Measurement office)
Department for Business, Innovation & Skills
Stanton Avenue
Date: 16 December 2009 Teddington
Valid Until: 12 July 2014 Middlesex TW11 0JZ
Reference No: T1128/0250 United Kingdom
2
Descriptive Annex
1 INTRODUCTION
This instrument utilises the digital indicating devices designated the Avery Weigh-Tronix
E1005/E1010 (Figures 1 and 2) connected to a weighing platform to form a Class III or IIII
mains operated self-indicating non-automatic weighing instrument.
2 FUNCTIONAL DESCRIPTION
2.1 Devices
The Avery Weigh-Tronix E1005/E1010 digital weight indicators are fully described in Test
Certificate No. GB-1179.
2.2 Load receptor
The indicator can be connected to a weigh platform to form a complete weighing system
providing that the conditions of Section 2.3 are met.
Load receptor types may be chosen from Table 1 in Section 3.2.
2.3 Load cells
2.3.1 Load cells may be chosen from Table 2 in Section 3.2, or any compatible load
cell(s) may be used providing the following conditions are met:
− There is a respective OIML Certificate of Conformity (R60) or a test
certificate (EN45501) issued for the load cell by a Notified Body responsible
for type examination under Directive 2009/23/EC.
− The certificate contains the load cell types and the necessary load cell data
required for the manufacturer’s declaration of compatibility of modules
(WELMEC 2, Issue 5, 2009, No 11), and any particular installation
requirements. A load cell marked NH is allowed only if humidity testing to
EN45501 has been conducted on this load cell.
− The compatibility of the load cells and indicator is established by the
manufacturer by means of the compatibility of modules calculation, contained
in the above WELMEC 2 document, at the time of verification or declaration
of EC conformity of type.
− The load cell transmission must conform to one of the examples shown in the
WELMEC Guide 2.4, “Guide for Load cells”.
2.3.2 The load cell cable(s) may be either connected internally and permanently
fitted to the indicator, using the watertight glands, or connected externally using waterproof
bayonet connectors, which have provision for sealing, in place of the watertight glands.
Note: Not applicable to Model E1005.
3
3 TECHNICAL DATA
3.1 Technical data for the indicator is provided in Test Certificate No. GB-1179.
3.2 Load receptors types and load cell list
The load receptors in the following tables are those types intended to be used with the load
cells in Table 2.
The load cells must be mounted correctly according to their mounting drawing.
Table 1
Type Load receptor No. of cells
Weighbridge All concrete platform with or without rails 4
All steel platform with or without rails 4
Steel + concrete platform with or without rails 4
All concrete platform with or without rails. Lever
system 1
All steel platform with or without rails. Lever system 1
Steel + concrete platform with or without rails. Lever
system 1
Platform scale Platform scale with corner load cells 4
“Bar” pair for pallet weighing 4 (2 per bar)
Platform scale with lever system 1
“Bar” pair for pallet weighing with two lever systems 2 per bar
“Single point” type 1
Overhead track
scale
Standard overhead track scale 1 or 2
Hopper Standard 3
Lever system + 1 load cell 1
4
Table 2
Load Cell Mounting Drawing Emax Vmin nmax
Avery 8701 (1), (2)
& (4)
70712-136 or 70714-162 50000, 100000 lb Emax / 14164 5000
Avery 8707 F3936 or F3937 6 - 30 kg Emax / 3500 3000
Avery 8708 (3) K13767 or
J300000000AA00 or
H500000000A300 or
E1018-1 or CK 13743
750 - 7000 kg Emax / 9259 4000
Avery 8713 (5) F4004, B72164-107 or
H40000000AAAA
125 - 500 kg Emax / 9615 4000
Avery T101 F3938 or C82347-165 60 - 300 kg Emax / 3500 3000
Avery T103 82151-191 or 82151-192 8 - 36 kg Emax / 3500 3000
Avery T103
AVR
E1002-49.IAD 8 - 36 kg Emax / 7500 6000
Avery T109 82151-191 or 82151-192 8 - 36 kg Emax / 3500 3000
Avery T110 70714-302, 82151-196 or
ISD04019
60 - 350 kg Emax / 3500 3000
Avery T201 BRT.171194.1 90 - 1100 kg Emax / 15000 5000
Avery T202 BRT.171195.1 500 - 5000 kg Emax / 10000 3000
Avery T203 (5) H400000000AAAA,
B72164-107, WMA5332,
WMA5320 or WS3244
125 - 500 kg Emax / 12500 6000
Avery T204 K13767 or
J300000000AA00 or
H500000000A300
750 - 3000 kg Emax /15000 4000
Avery T302 ( 2), (4)
70712-136 or 70714-162 50000 or 100000
lb
Emax/15000 5000
Avery or Salter
Weigh Bar
E 1062-1.IAD 220 – 5000 kg Emax / 10000 7000
220 – 34000 kg 5000
Epel SC E1049-1.IAD 750 to 1500 kg Emax/10000 3000
Flintab RC1 4-85105 250, 400 kN Emax/7000 3000
Flintab SB4 4-85105 500 - 10000 kg Emax/11000 3000
HBM BLC, TLC,
HLC, THC
E1018-1.IAD 220 to 4400 kg Emax/10000 3000
HBM C2A 70712-136 or 70714-162 1 to 10 t Emax/10000 4000
HBM
C15AC./..T &
C15BC./..T
E1041-1.IAD 20 to 100 t Emax/10000 4000
HBM C16 AC 70712-136 or 70714-162 12 to 60 t Emax/12000 4000
HBM
PWS/PWSM
70714-302 or 82151-196 7 to 150 kg Emax / 7143 3000
5
Load Cell Mounting Drawing Emax Vmin nmax
HBM PW2 82151-191 or 82151-192 7.2 kg Emax / 3600 3000
12 kg Emax / 6000 3000
Emax / 12000 3000
13 kg Emax / 6500 3000
18 kg Emax / 3600 3000
Emax / 9000 3000
36 kg Emax / 3600 3000
72 kg Emax / 3600 3000
HBM SP4 82151-191 or 82151-192 7 to 100 kg Emax / 7143 3000
HBM Z6 70714-298 or 70714-297 50 - 250 kg Emax/10000 3000
Huntleigh 355 PLP2 5 - 500 kg Emax/15000 4000
Molen CSP-M 70712-136 or 70714-162 5 to 100 t Emax/5000 1000
Emax/10000 2000
Emax/10000 3000
Emax/11666 3500
Philips
PR6222/..C3
70712-136 or 70714-162 20 to 50 t Emax/10000 3000
Revere BSP E1002-49.IAD 50 to 5000 kg Emax/10000 3000
Revere CSP M E2001-12.IAD or E2001-
13.IAD
10 - 60 t Emax / 8333 3000
Revere HPS E2001-20.IAD 6 - 60 kg Emax / 12000 3000
Revere RLC E2001-14.IAD 500 to 5000 kg Emax/7000 3000
Emax/9333 4000
Emax/11667 5000
Emax/14000 6000
Revere SHB M PLP2 20, 50, 100, 200,
500, 1000 kg
Emax/7143 3000
Revere SSB BJA060843 500 - 5000 kg Emax/10000 3000
Revere S5222
and S5223
E1002-66.IAD 20 to 45 t Emax/10000 3000
Revere 5102 6000LD/LP, 6000DT/P
or H506-6000U
50 to 10000 lb Emax/10000 2000
Emax/10000 3000
Revere 92 70712-136 or 70714-162 50000 to 200000
lb
Emax/8500 3000
Sensortronics
65023C
E1002/41.IAD 1000 - 10000 lb
500 - 5000 kg
Emax/1000 3000
Shering
SCL20SA
70712-136 or 70714-162 10 t to 100 t Emax/8333 3000
Tedea Huntleigh
1040
E1002-30 5 - 100 kg Emax/10000 3000
Tedea Huntleigh
1140
E1002-30 or LDP2 15 to 200 kg Emax/7500 3000
Tedea Huntleigh
1250
LCT2000000BA00 or
LCT3000000CA00
50 - 500 kg Emax/10000 3000
6
Load Cell Mounting Drawing Emax Vmin nmax
Tedea Huntleigh
1320
E1002-47.IAD 1 to 2 t Emax/10000 3000
Tedea Huntleigh
3410
E2001-14.IAD 450 to 1800 kg Emax/10000 3000
Tedea Huntleigh
3510
PLP1 or E1055-1.1 0.5 to 5 t Emax/4000 1000
Emax/8000 3000
Emax/12000 3000
Tedea Huntleigh
HSB
PLP1 500 - 5000 kg Emax/13333 3000
Thameside T66 LDP 20 - 200 kg Emax/10000 3000
Thameside T95 FS-TS-T95 2, 5, 10 or 20 t Emax/5000 1000
Emax/10000 2000
Emax/10000 3000
Notes:
( 1 ) The weighing system must be linearised by the indicator when 8701 cells are used.
( 2 ) The Avery 8701 load cell approved under this type approval certificate is technically
compatible and freely interchangeable with the Avery T302. Any weighing
instrument verified under this approval may incorporate a mix of both the 8701 and
T302 load cells.
( 3 ) The Avery 8708 load cell approved under this type approval certificate is technically
compatible and freely interchangeable with the Avery T204 load cell.
( 4 ) The Avery 8701 and T302 load cells may be incorporated into a multi-interval
instrument, with two partial ranges, of not more than 4000 divisions per partial range.
( 5 )
The Avery 8713 load cell approved under this type approval certificate is technically
compatible and freely interchangeable with the Avery T203 load cell.
3.3 Having the following load cell:
Load Cell Mounting Drawing No. nmax
T203 B72164-107, WMA5332,
WMA5320 or WS3244 n ≤ 4000 for a multi-interval instrument
with not more than 2 ranges.
7
3.4 Having an Avery beam type load cell between the transfer lever and the dead
structure of a mechanical instrument converted to use one of the types of indicator described
in this certification and having not more than 3000 digital scale intervals. Approved types are
listed below:-
Load cell Platform/Weighbridge type Drawing No
8713 Avery 8938 F4004
8708 Avery 8940 K13767
8708 Quadrelli ‘Traghetto’ E1001-01 through E1001-52
T203 Avery 8938 F4004
T109 Avery 89S E1047-1.IAD
Having the Avery 8708 load cell with not more than 4000 digital scale intervals.
Having the HBM Z3 load cell with the following characteristics:
Load cell type Emax nmax Y
Z3H2
Z3H3
10 kg – 2000 kg
10 kg – 2000 kg
2000
3000
7000
8400
Z3H2-A
Z3H3-A
50 kg – 2000 kg
50 kg – 2000 kg
2000
3000
7000
8400
3.5 Having an overhead track weighing device.
The device is constructed according to drawing number H100000000AAAA or
4150000000AAOO.
The load cells are Avery type 8713.
The device has a length between and including 300 mm and 1200 mm and a capacity of
either 300 kg by 0.1 kg or 600 kg by 0.2 kg.
3.6 Having an H205 platform using a T103 or T109 load cell, with the following
three alternative AVR (Automatic Variable Resolution) capacities:
capacity 6 kg with e = 1 g from 0 to 3 kg
and e = 2 g from 3 kg to 6 kg (T103 only)
capacity 15 kg with e = 2 g from 0 to 7.5 kg
and e = 5 g from 7.5 kg to 15 kg (T103 only)
capacity 30 kg with e = 5 g from 0 to 15 kg
and e = 10 g from 15 kg to 30 kg
The load cell mounting is shown in Drawing No 82151-191 or 82151-192.
3.7 Having Zenner barriers fitted to the excitation, sense (reference) and signal
lines of the cable, between the load cell and the indicator.
8
3.8 Having the indicator connected to H5XX series load receptors comprising four
Avery 8708 load cell graded for 6000 V. The load receptor is constructed according to
drawing number H500000000A300.
The system has a capacity of between and including 1200 kg and 6000 kg and has not more
than 6000 scale intervals.
The 8708 load cell can be used for partial weighing operation having two partial ranges
where n ≤ 4000 divisions per range.
3.9 Having an Avery H305 platform, incorporating a T110 load cell, connected to
the indicator. In which case n ≤ 6000 for a single range instrument or ni ≤ 4000 for a multi-
interval instrument with not more than 2 ranges.
3.10 Having an Avery H4xx platform, connected to the indicator, having platform
construction details as shown in the following table:
Construction Drawing Load Cell nmax
E1059-1.IAD
or
E1060-1.IAD
Avery T203 n ≤ 6000 for a single range instrument.
ni ≤ 4000 for a multi-interval instrument with not
more than 2 ranges.
E1059-1.IAD Avery 8708 n ≤ 6000
3.11 Having a pallet truck weigher platform, connected to the indicator, using the
load cells described below:
Load Cell Emax Mounting Drawing vmin nmax
Tedea Huntleigh 3410 450 - 1800 kg E 2001-14.IAD Emax/10000 3000
Tedea Huntleigh 3510 0.5 - 5 t PLP1 or E1055-1.1 Emax/4000 1000
Emax/8000 2000
Emax/12000 3000
The pallet truck weigher platform will have a level indicator.
3.12 Having an H303/281 LC platform, incorporating a T110 load cell, connected
to the indicator, in the following capacities:
Max e Load cell capacity
60 kg 20 g 180 kg
150 kg 50 g 350 kg
9
3.13 Having any of the range of indicators connected to platforms incorporating the
Avery T204 load cell having the following characteristics:
- for multi-interval operation with not more than two partial weighing ranges
and nmax = 4000 for each partial weighing range. Having the T204 load cells
with Emax of 750 kg, 1500 kg and 3000 kg.
- for single interval operation with nmax = 6000 and using the T204 load cell
with Emax values as listed above.
3.14 Having a mechanical platform incorporating a load cell and lever arrangement
designated Model SH1000. The platform is manufactured from painted mild steel or with a
stainless steel plate and mild steel base and internal components and can have platform
dimensions from 0.80 m x 0.80 m to 1.50 m x 2.00 m.
The platform may have the following capacities utilising either the Avery T201, T203 or
T204 load cells as shown in the following table:-
Platform dimension Capacity Load cell Alternative load cell
0.80 m x 0.80 m 300 kg
600 kg
T203 – 125 kg
T203 – 250 kg
T201 – 90 kg
T201 – 225 kg
1.00 m x 1.00 m 600 kg
1000 kg
T203 – 125 kg
T203 – 250 kg
T201 – 90 kg
T201 – 225 kg
1.00 m x 1.25 m 600 kg
1500 kg
T203 – 125 kg
T203 – 250 kg
T201 – 90 kg
T201 – 225 kg
1.25 m x 1.50 m 600 kg
1500 kg
3000 kg
T203 – 125 kg
T203 – 250 kg
T203 – 500 kg
T201 – 90 kg
T201 – 225 kg
T201 – 450 kg
1.50 m x 1.50 m 600 kg
1500 kg
3000 kg
T203 – 125 kg
T203 – 250 kg
T203 – 500 kg
T201 – 90 kg
T201 – 225 kg
T201 – 450 kg
1.50 m x 2.00 m 1500 kg
3000 kg
6000 kg
T203 – 250 kg
T203 – 500 kg
T204 - 1500
T201 – 225 kg
T201 – 450 kg
T201 – 1100 kg
3.15 Having the indicator connected to an Avery J3xx load receptor comprising
four Avery 8708 load cells graded for 6000v. The load receptor is constructed according to
drawing number J300000000AA00.
The system has a capacity of between and including 1200 kg to 12000 kg and has not more
than 6000 scale intervals.
3.16 Having the indicator connected to an Avery Berkel H4xx, H5xx or J3xx series
load receptor comprising four Revere HCB load cells graded for 6000v. The load cells may
alternatively be designated Avery T205.
The load receptors are constructed according to drawing numbers E1059-1.IAD,
H500000000A300 or J300000000AA00 respectively.
The system has a capacity of, between and including, 1200 kg and 6000 kg with not more
than 6000 scale intervals.
10
3.17 Having the manufacturer designated as Berkel Prior.
3.18 Having alternative load receptors utilising the following load cells. Where a
reduced operating temperature range is specified, this shall be included in the descriptive
markings.
Manufacture
r Type Capacity
No. of scale
intervals
Max. no.
of load cells
Temperature
range
Revere 363 2,000 & 3,000 lb 3000 1 -10 to +40 °C
Revere CP1 50,000 & 100,000 lb 3000 6 0 to +30 °C
Sensortronics
60001 1,000 & 2,000 lb 3000 1 0 to +30 °C
Toledo CS Capcheck
50,000 lb & 100,000 lb 3000 6 0 to +30 °C
Solidate SB2 35,000 & 45,000 lb 3000 6 0 to +30 °C
BLH/Toledo C2PI 50,000 lb 2500 4 0 to +30 °C
HBM CISF 50,000 & 100,000 lb 2500 4 0 to +30 °C
HBM C3H2 30,000 kg 3000 6 -10 to +40 °C
4 PERIPHERAL DEVICES
4.1 The weighing system may be connected to any peripheral devices that have
been issued with a test certificate by a Notified Body responsible for type approval under
Directive 2009/23/EC in any Member State and bears the CE marking of conformity to the
relevant directives; or
Peripheral devices without a test certificate under the following conditions:
− it bears the CE marking for conformity to the EMC Directive;
− it is not capable of transmitting any data or instruction into the weighing
instrument, other than to release a printout, checking for correct data
transmission or validation;
− it prints weighing results and other data as received from the weighing
instrument without any modification or further processing;
− it complies with the applicable requirements of EN45501, i.e. 4.2, 4.4, 4.6 and
4.7.
11
4.2 Data storage device (DSD)
A data storage device (DSD) having a Test Certificate (TC) may be connected to The
weighing system if at conformity assessment for putting into service for an Article 1.2(a)
application, it is checked that the requirements 6.1, 6.2, 6.4, 6.5 and 6.6 of WELMEC 2.5,
Issue 2, 2000 are met.
The DSD must have sufficient capacity to store data for a minimum of 90 days after the data
has been used for invoicing.
5 APPROVAL CONDITIONS
The certificate is issued subject to the following conditions:
5.1 Legends and inscriptions
5.1.1 The instrument shall bear the following legends near the display of the
weighing result:
Max
Min
e =
5.1.2 The instrument shall bear the following legends (Figure 3):
CE marking
Verification mark
Green M
Class
Serial number
Manufacture’s mark or name
Certificate number
5.2 The E1005 indicator may be used for “direct sales to the public” if the
“Select” function key is inactive. The E1010 indicator may be used for “direct sales to the
public” if the pre-set tare device and “Select” function key are inactive.
5.3 A levelling device sensitive enough to display a 2/1000 tilt shall be fixed
firmly to the weighing instrument in a place clearly visible to the user, unless the instrument
is freely suspended or installed in a fixed position.
6 LOCATION OF SEALS AND VERIFICATION MARKS
6.1 The CE mark, Green M and Certificate number will be mounted on the rear of
the indicator. The data plate will be mounted in such a manner that it is easily accessible and
clearly visible in its regular operating position. The CE mark shall be impossible to remove
without damaging it. The data plate shall be impossible to remove without it being destroyed.
The markings and inscriptions shall fulfil the requirements of Paragraph 1 of Annex IV of the
Directive 2009/23/EC.
12
6.2 Access to the configuration and calibration facility is password protected as
detailed in GB-1179.
Alternatively, access can be via a push button located on the rear of the instrument (E1005),
which is accessed by removing the switch cover plate, or on the main PCB (E1010), which is
accessed by removing the front cover of the enclosure. The switch cover plate and the
enclosure(s) can be sealed using a wire and lead seal. N.B. only one of these methods will be
present on an instrument.
Components that may not be dismantled or adjusted by the user (e.g. load cell connection),
and load cell junction boxes where applicable, will be secured by either a wire and lead seal
or tamper evident label and securing mark. The securing mark may be either:
− a mark of the manufacturer and/or manufacturer’s representative, or
− an official mark of a verification officer.
7 ALTERNATIVES
7.1 The indicator may bear the following alternative manufacturers name and
model:
− Salter Brecknell Dp 90 (plastic) or Dp 95 (stainless steel).
7.2 The indicator may be mounted on a simple fold-away stand, a swivel mounted
stand, or an extended stand for wall mounted applications.
7.3 The Avery 8701 load cell approved under this type approval certificate is
technically compatible and freely interchangeable with the Avery T302, T302i and T302x
load cells. Any weighing instrument verified under this approval may incorporate a mix of
8701, T302, T302i and T302x load cells.
8 ILLUSTRATIONS
Figure 1 E1005 indicator general view
Figure 2 E1010 indicator general view
Figure 3 Data plate
13
9 CERTIFICATE HISTORY
ISSUE NO. DATE DESCRIPTION
UK 2723 13 July 2004 Type approval first issued.
UK 2723 Revision 1 1 September 2004 Revision 1 issued. Increase in the number of
scale intervals to 10000.
UK 2723 Revision 2 25 January 2005 Section 2.3.2 added.
Load cell T302 added to Note (4) at
Section 3.2.
UK 2723 Revision 3 11 May 2005 Partial weighing ranges reduced from 3 to 2
and the maximum number of verification
scale intervals per partial weighing range
increased from 3000 to 5000
UK 2723 Revision 4 17 October 2005 Minor modifications to Table 2.
Note (5) added to Section 3.2.
Sections 3.4 to 3.18 and 4.2 added.
UK 2723 Revision 5 19 April 2006 3 ranges corrected to 2 ranges in Sections 3.3,
3.10 & 3.13.
Partial ranges increased to 4000 divisions for
Avery load cells: 8701, 8708, T110, T202,
T303 & T204.
6 kg crossover capacity changed to 7.5 kg for
15 kg cell in Section 3.6.
UK 2723 Revision 6 16 December 2009 Alternative 7.3 added.
14
Figure 1 E1005 indicator general view
15
Figure 2 E1010 indicator general view
Figure 3 Data plate
Crown Copyright 2009
NATIONAL WEIGHTS AND MEASURES LABORATORY
(Part of National Measurement Office)
Department for Business, Innovation & Skills