Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measurement (T&M) equipment. We stock all major equipment types such as spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers for whom high performance, quality and service are key, whilst realising the cost savings that second user equipment offers. As such, we fully test & refurbish equipment in our in-house, traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2 year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of combined experience, which enables us to deliver industry-leading service and support. We endeavour to be customer focused in every way right down to the detail, such as offering free delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan unit, if available) and supplying a free business tool with every order.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off balance sheet accounting. Both second user and rental improve the key business measure of Return On Capital Employed.
We are based near Heathrow Airport in the UK from where we supply test equipment worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house Lab.
All products supplied by Test Equipment Solutions include:
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).- Free loan equipment during warranty repair, if available.- Full electrical, mechanical and safety refurbishment in our in-house Lab.- Certificate of Conformance (calibration available on request).- Manuals and accessories required for normal operation.- Free insured delivery to your UK mainland address (sales).- Support from our team of seasoned Test & Measurement engineers.- ISO9001 quality assurance.
Test equipment Solutions LtdUnit 8 Elder WayWaterside DriveLangleyBerkshireSL3 6EP
T: +44 (0)1753 596000F: +44 (0)1753 596001
Email: info@TestEquipmentHQ.comWeb: www.TestEquipmentHQ.com
Agilent Technologies
Optical Component Test
Agilent Lightwave Mainframes
Faster reaction times in alignment and adjustment applications
Significantly shorter measurement and data transfer times
Faster measurement data transfer in remote applications
Reduced test times and cost of test
Elimination of associated costs andtime-consuming setup
Flexibility & Scalability
ErgonomicColor, high-contrast, brightness, lowreflection display and a wide viewingangle is key for benchtop applications.
EfficientOn top of the plug&play drivers theAgilent Photonic Foundation Libraryprovides a variety of application func-tions that increase the measurementperformance and reduce test imple-mentation cost.
Agilent Photonic Foundation Library
Optical Component TestAgilent 8163B Lightwave MultimeterAgilent 8164B Lightwave Measurement SystemAgilent 8166B Lightwave Multichannel System
FlexibleA free combination of the Agilentmodules allows to easily generate different measurement setups.
The system can be controlled eitherdirectly for benchtop, or with an exter-nal PC for remote applications. Internal applications (Loss overWavelength, Return Loss, Logging,Stability) can be used directly.
FastThe Agilent Lightwave mainframes areoptimized for test speed and thereforeminimize test cost.
ScalableHigh and low channel applications canbe addressed by the easy extendabili-ty of the mainframes. “The right formfactor” for each setup!
The Agilent Optical Component Test Platformfor flexible and scalable test solutions withsmall footprint
Agilent 8164B Lightwave Measurement System
Optical Component TestThe Agilent Flexible Test Platforms help Reduce EngineeringEffort with a Modular Concept.
AttenuatorModules
Return LossModules
Power SensorModules
Optical Heads
Agilent 8163B Lightwave MultimeterAgilent 8166B Lightwave
Multichannel System
Tunable Laser Modules(only for 8164B)
Fast and easy-to-read measurement valueson the high-resolution color display
Compact Tunable LaserModules
DistributedFeedback (DFB)Laser Modules
Agilent 8163B, 8164B and 8166Bmainframes address different measu-rement needs for passive and activelightwave components with high portflexibility. The Agilent 8163B mainfra-me features dedicated benchtop appli-cations with direct user interactions.
The Agilent 8164B is optimized fortesting devices such as multiplexersand demultiplexers, fiber bragg gra-tings, or thin film filters. A test set upwith the Agilent 8166B is ideal forhigh port device and optical amplifiertest. Internal applications (Loss overWavelength, Return Loss, Logging,Stability) can be used directly.
Fabry PerotLaser Modules
Tunable Laser
81600B, 81480B, 81640B, 81680B
Tunable Laser
81672B, 81482B, 81642B, 81682B,
Compact Tunable Laser
81649A, 81689A/B
Distributed Feedback (DFB) Laser
81662A, 81663A
Fabry-Perot Laser
Power Meter
8163xB
Optical Heads
Return Loss Modules
81610A, 81611A, 81612A
81613A, 81614A
Attenuator
81560A/61A,66A, 67A
81570A/71A/73A/76A/77A
Switches 8159x
Polarization Controller 8169A
Polarization Controller 11896A
Digital Communications Analyzer
(DCA)
Bit Error Ratio Tester (BERT)
SONET/SDH Tester
Optical Spectrum Analyzer (OSA)
Mainframes 8163A/B
8164A/B
8166A/B
All Parameter Test
Photonic Foundation Library
Passive Component Test Optical Amplifier Test Bit Error Ratio Test
Mux
/DeM
ux/V
-Mux
TFF
Test
FBG
Filt
er T
est
Conn
ecto
r Tes
t
Switc
h Te
st
TFF
Alig
n-/A
djus
tmen
t
Fibe
r to
AW
G A
lignm
ent/
AW
G C
hip
Test
Coup
er/S
plitt
er/C
ombi
ner
Isol
ator
/Circ
ulat
or
Varia
ble
Opt
ical
Att
enua
tor
Gai
n Fl
atte
ning
Filt
er
Dis
pers
ion
Com
pens
ator
s
Inte
rleav
er
EDFA
Ram
an A
mpl
ifier
s
SOA
Rx/
Tx
Line
Car
d
Syst
em T
est
By internet, phone, or fax, get assistance with all your test & measurement needs
For further information, please visit www.agilent.com/comms/comp-test
Netherlands: France: Italy: Germany: Spain: UK: Sweden:
(tel) +31-20-547 2110 (tel) +33-16453 5625 (tel) +39-02-9260 8206 (tel) +49-7031-464 3295 (tel) +34-91-631 3213 (tel) +44-118-927 6690 (tel) +46-8-444 8672
(tel) +31-20-547-2281
United States: Europe: Latin America: New Zealand: Asia Pacific: Canada: Japan: Australia:
(tel) 1 800 452 4844 (tel) (31 20) 547 2323 (tel) (305) 269 7500 (tel) 0 800 738 378 (tel) (852) 3197 7777 (tel) 1 877 894 4414 (tel) (81) 426 56 7832 (tel) 1 800 629 485
(fax) (31 20) 547 2390 (fax) (305) 269 7599 (fax) 64 4 495 8950 (fax) (852) 2506 9284 (fax) (905) 282-6495 (fax) (81) 426 56 7840 (fax) (61 3) 9210 5947
Product specifications and descriptions in this document subject to change without notice.
Printed May 6th, 2002
Copyright © 2001 Agilent Technologies
5988-3989EN
Optical
Component Test
Test Innovations That Improve Your Bottom Line
This guide provides configuration details for the Agilent 816xB family of mainframes and modules, including options and accessories.
Agilent Lightwave Solution Platform Configuration Guide May 2005
Page 2 of 16
8163B Lightwave Multimeter Main features:
• Ideal for laboratory and portable usage
• 2 compact module slots
• Built in applications: Return Loss, Passive Component Test, Stability, Logging
• GPIB Interface for remote control
• Full backward compatibility for 815xx and 816xx series modules.
8164B Lightwave Measurement System Main features:
• Ideal for laboratory or rack mount usage for state-of-the-art applications
• 1 extended module slot for back-loadable tunable laser sources
• 4 compact module slots
• Built in applications: Passive Component Test, Stability, Logging
• Integrated floppy disk for direct setup and data access
• GPIB Interface for remote control
• Full backward compatibility for 815xx and 816xx series modules.
8166B Lightwave Multichannel System Main features:
• Ideal for laboratory or rack mount usage for applications that require high port counts
• 17 compact module slots
• GPIB Interface for remote control
• Backward compatibility for 8156x, 8157x, 8159x and 816xx series modules.
Mainframe and Module Firmware: → For Firmware upgrades and download tools see http://www.agilent.com/comms/octfirmware
Page 3 of 16
Module compatibility 8163B Slots 1 – 2 8164B Slot 0 8164B Slots 1 – 4 8166B Slots 1 – 17
81600B TLS family #200, #160, #150, #140, #130 low SSE #142, #132 high power
page 4 page 4
X X
81980A compact TLS 81940A compact TLS 81989A compact TLS 81949A compact TLS 81944A compact TLS
page 5 page 5 page 5 page 5 page 5
X X X X X
X X X X X
X X X X X
81662A DFB source module 81663A DFB source module
page 6 page 6
X X
X X
X X
81650A FP source module 81651A FP source module 81654A FP source module 81655A FP source module 81656A FP source module 81657A FP source module
page 7 page 7 page 7 page 7 page 7 page 7
X X X X X X
X X X X X X
X X X X X X
81630B power measurement module 81634B power measurement module 81635A power measurement module 81636B power measurement module
page 8 page 8 page 8 page 8
X X X X
X X X X
X X X X
81618A interface module 81619A dual interface module
81623B optical head 81624B optical head 81626B high power optical head 81628B high power optical head with integrating sphere
page 9/10 page 9/10
page 9 page 9 page 9
page 10
X X
X X X
X
X X
X X X
X
X X
X X X
X
81610A return loss module 81613A return loss module
page 11 page 11
X X
X X
X X
81570A attenuator module (SM) 81571A attenuator module (SM) 81576A attenuator module with p/c 81577A attenuator module with p/c 81578A attenuator module (MM)
page 12 page 12 page 12 page 12 page 12
X X
X (dual) X (dual)
X
X X
X (dual) X (dual)
X
X X
X (dual) X (dual)
X
81591B optical switch module 1x2 81594B optical switch module 2x2 81595B optical switch module 1x4
page 13 page 13 page 13
X X X
X X X
X X X
Legacy Module compatibility The discontinued 8163A, 8164A and 8166A mainframes are functionally compatible with the B versions. 8163B Slots 1 – 2 8164B Slot 0 8164B Slots 1 – 4 8166B Slots 1 – 17
814xxA/B backloadable TLS modules 816xxA/B backloadable TLS modules
X X
816xxA/B compact TLS modules X X X
Other 816xx series modules X X X
8156xA, 8157xA attenuator modules X X X
8159xA/S switch modules X X X
All other 815xx series modules X X
Page 4 of 16
81600B Tunable Laser Source family
Connector Interfaces for straight connectors
2 ea required for 81600B #200, 160, 150, 140, 130.
1 ea required for 81600B #142, 132.
81000FI FC/PC key width 2.2 mm 81000HI E-2000/PC 81000KI SC/PC 81000LI LC/PC 81000MI MU/PC 81000SI DIN 47256/PC 81000VI ST/PC
Connector Interface for angled connectors
2 ea required for 81600B #200, 160, 150, 140, 130.
1 ea required for 81600B #142, 132.
81000FI FC/APC key width 2.2 mm 81000NI FC/APC key width 2.0 mm 81000HI E-2000/APC 81000KI SC/APC 81000LI LC/APC 81000MI MU/APC 81000SI DIN 47256/APC, 81000VI ST/APC
Tunable Laser Sources Low SSE modules
81600B #200: 1440 nm – 1640 nm
81600B #160: 1495 nm – 1640 nm
81600B #150: 1450 nm – 1590 nm
81600B #140: 1370 nm – 1495 nm
81600B #130: 1260 nm – 1375 nm
Tunable Laser Sources High Power modules
81600B #142: 1370 nm – 1495 nm, +8.5 dBm
81600B #132: 1260 nm – 1375 nm, +9 dBm
81600B-071
PMF Straight contact connector
Tunable Laser Sources
Outputs: High Power
only
Note: 81600B - 072 is highly recommended over 81600B - 071 to reduce front-panel reflections, which will greatly reduce interference noise and spectral ripple in the test setup.
Connector Interfaces
for straight connectors
Connector Interfaces for angled connectors
For Laser Safety information see page 14
OPTIONAL
MANDATORY AND MUTUALLY EXCLUSIVE
81600B-072
PMF Angled contact connector
81600B-003 with built-in attenuator
(81600B #142 only)
Tunable Laser Sources
Outputs: Low SSE and High Power
Page 5 of 16
High Power Compact Tunable Laser Source modules
819xxA-072
PMF Angled contact
connector
Connector Interfaces for
angled connectors
High Power Compact
Tunable Laser Source module
819xxA-071
PMF Straight contact
connector
High Power Compact Tunable Laser module
81980A Compact Tunable Laser 1465 nm – 1575 nm 81940A Compact Tunable Laser 1520 nm – 1630 nm 81989A Compact Tunable Laser 1465 nm – 1575 nm 81949A Compact Tunable Laser 1520 nm – 1630 nm 81944A Compact Tunable Laser 1525 nm – 1625 nm for PMD tester system N3909A
Connector Interfaces for angled connectors
1 ea required
81000FI FC/APC key width 2.2 mm 81000NI FC/APC key width 2.0 mm 81000HI E-2000/APC 81000KI SC/APC 81000LI LC/APC 81000MI MU/APC 81000SI DIN 47256/APC 81000VI ST/APC
Connector Interfaces for straight connectors
Note: 819xxA - 072 is highly recommended over 819xxA - 071 to reduce front-panel reflections, which will greatly reduce interference noise and spectral ripple in the test setup.
Connector Interfaces for straight connectors
1 ea required
81000FI FC/PC key width 2.2 mm 81000HI E-2000/PC 81000KI SC/PC 81000LI LC/PC 81000MI MU/PC 81000SI DIN 47256/PC 81000VI ST/PC
For Laser Safety information see page 14
OPTIONAL
MANDATORY AND MUTUALLY EXCLUSIVE
Page 6 of 16
DFB Source modules
Wavelength option
Connector Interfaces
for angled contact connectors
81662A DFB Source, +10 dBm C- and L- band
81663A DFB Source, +13 dBm C-and L-band
Connector Interfaces for angled connectors
1 ea required
81000FI FC/APC key width 2.2 mm 81000NI FC/APC key width 2.0 mm 81000HI E-2000/APC 81000KI SC/APC 81000LI LC/APC 81000MI MU/APC 81000SI DIN 47256/APC 81000VI ST/APC
For Laser Safety information see page 14
OPTIONAL
MANDATORY AND MUTUALLY EXCLUSIVE
DFB Source
Wavelength determined by option number
For special wavelengths, contact Agilent.
Page 7 of 16
Fabry-Perot Laser modules
FP High Power Source Modules 13 dBm
81655A 1310nm 81656A 1550 nm 81657A 1310/1550 nm
FP Standard Source Modules 3 dBm
81655A #E01 850 nm
FP Standard Source Modules 0 dBm
81650A 1310 nm 81651A 1550 nm 81654A 1310/1550 nm
Connector Interfaces for straight connectors
1 ea required
81000FI FC/PC key width 2.2mm
81000HI E-2000/PC
81000KI SC/PC
81000LI LC/PC
81000MI MU/PC
81000SI DIN 47256/PC
81000VI ST/PC
Source Modules
SMF, Straight contact
interface
For Laser Safety information see page 14
OPTIONAL
Connector
Interfaces for straight
connectors
Page 8 of 16
Optical Power Measurement modules
Optical Power measurement modules
81630B +28 dBm to –70 dBm
81634B +10 dBm to –110 dBm
81635A +10 dBm to –80 dBm (dual channel)
81636B +10 dBm to –80 dBm (Fast Power Sensor)
Connector Interfaces
1 ea required for 81630B, 81634B, and 81636B
2 ea required for 81635A
81000FI FC/PC key width 2.2mm 81000NI FC/APC key width 2.0mm 81000KI SC/PC/APC 81000PI E-2000 PC/APC 81000SI DIN 47256 PC/APC 81000VI ST/PC/APC 81002LI LC/PC/APC 81002MI MU/PC/APC
81000BI Bare Fiber Connectivity Set for 81630B, 81634B Sensors (not to be used for 81635A and 81636B)
81004BH 10 Bare Fiber Holder for fibers <400µm diameter 81009BH 10 Bare Fiber Holder for fibers 400 - 900µm diameter
Note: All sensor inputs are non-contact and accept both straight and angled connectors.
(bare fiber)
Connector Interfaces
OPTIONAL
Sensor Module
Interface (for both
angled & straight connectors).
Bare Fiber Connectivity (for 81630, 81634 series)
81000BI
Page 9 of 16
Optical Heads (5 mm sensor)
OPTIONAL
Connector Adapters (threaded)
81000BT Bare Fiber Connectivity Set (Threaded) 81000FA FC/PC/APC 81000KA SC/PC/APC 81000VA ST 81003LA LC 81000PA E-2000
Interface Modules
81618A Single Head Interface Module
81619A Dual Head Interface Module
Optical Heads
81623B Ge +10dBm to –80 dBm (spec for 750 – 1800nm)
81624B InGaAs +10dBm to –90 dBm
81626B InGaAs +27dBm to –70 dBm
Accessories
81624CE 4 m extension cable
81624DD additional D-shape quick change adapter
81624RM Half-rack Mount Kit for 2 Heads
81625RM Rack Mount Kit for 4 Heads
Connector Adapters (with integral D-Shape)
81624DD D-Shaped adapter not required
81000BC Bare Fiber Connectivity Set (D-shaped) 81001FA FC 81001KA SC 81001LA LC 81001MA MU 81001PA E-2000 81001ZA BLANK Adapter
Optical Heads for:
Connectorized Fiber, Bare Fiber and
Open beam NA ≤ 0.3
Interface Module
Filter / Holder
81010BL Lens for 1300/1550 nm, single mode
81050BL Lens for 1300/1550 nm, multi mode
Filter Holder
[1]
Connector Adapters
(threaded).
D-Shaped Adapter 81624DD (supplied with head)
For advanced accuracy see „Special Calibration“ options C01/02 and C85/86
Integral
D-Shaped Adapters
Page 10 of 16
High Power Optical Head (with integrating sphere)
OPTIONAL
Interface Modules
81618A Single Head Interface Module
81619A Dual Head Interface Module
Accessories
81624CE 4 m extension cable
High Power
Optical Head for: Connectorized Fiber,
Bare Fiber and Open beam NA ≤ 0.3
81628B InGaAs +40 dBm to –60 dBm
Connector Adapters
(threaded).
Interface Module
Connector Adapters (threaded)
81000BT Bare Fiber Connectivity Set (Threaded) 81000FA FC/PC/APC 81000KA SC/PC/APC 81000VA ST 81003LA LC 81000PA E-2000
Page 11 of 16
Return Loss modules For Laser Safety information see page 14
OPTIONAL
81610A Return Loss Module (without internal source)
81613A Return Loss Module (1310/1550 nm internal source)
Return Loss
Module
Angled contact interfaces
Connector Interfaces for angled connectors
2 ea required for 81610A.
1 ea required for 81613A, (2 ea required if using external source input).
81000FI FC/APC key width 2.2 mm 81000NI FC/APC key width 2.0 mm 81000HI E-2000/APC 81000KI SC/APC 81000SI DIN 47256/APC 81000VI ST/APC 81000LI LC/APC 81000MI MU/APC
Reference Cable
81610CC Reference Cable – for calibration of all 8161xA Return Loss Modules
Connectors - DIN 47256/APC (connects to module) and FC/PC (supplied with calibrated return loss values to open air)
An 81000SI connector interface is required to connect this cable to the module.
This cable is used for calibration only, not for measurements.
Caution: Do not make physical contact to the FC/PC connector and do not attach another connector to it. This could change the calibrated (open) return loss values.
DIN 47256/APC FC/PC
Connector Interface for angled contacts
81610CC
or
Standard patch cord
81000UM 81000BR
Page 12 of 16
Optical Attenuator modules
OPTIONAL
Optical
Attenuator Angled Contact
Connectors
Optical Attenuators with Angled Contact Connectors
81571A (single slot) Optical Attenuator for high power
81577A (dual slot) Optical Attenuator with Power Control for high power
Connector Interfaces (input and output):
2 ea required
81000FI FC/APC key width 2.2 mm 81000NI FC/APC key width 2.0 mm 81000HI E-2000 APC 81000KI SC/APC 81000LI LC/APC 81000MI MU/APC 81000SI DIN 47256/APC 81000VI ST/APC
Optical Attenuators with Straight Contact Connectors
81570A (single slot) Optical Attenuator single-mode applications
81578A (single slot) Optical Attenuator multi-mode applications #050: 50µm fiber interface #062: 62.5µm fiber interface
81576A (dual slot) Optical Attenuator with Power Control for high power
Connector Interfaces (input and output):
2 ea required
81000FI FC/PC key width 2.2 mm 81000HI E-2000 PC 81000KI SC/PC 81000LI LC/PC 81000MI MU/PC 81000SI DIN 47256/PC 81000VI ST/PC
Connector Interface for
straight connectors
Connector Interface for
angled connectors
Optical
Attenuator Straight Contact
Connectors
Page 13 of 16
Optical Switch modules
OPTIONAL
Single-mode Optical Switch
with Angled Contact
FC/APC – R Connectors (key width
2.0mm)
Optical Switches (single-mode) with Angled Contact Connectors
81591B #009 (single slot) Optical switch 1x2 for single-mode applications
81594B #009 (single slot) Optical switch 2x2 for single-mode applications
81595B #009 (single slot) Optical switch 1x4 for single-mode applications
Optical Switches (multi-mode) with Straight Contact Connectors
81591B #062 (single slot) Optical switch 1x2 for multi-mode applications
81594B #062 (single slot) Optical switch 2x2 for multi-mode applications
81595B #062 (single slot) Optical switch 1x4 for multi-mode applications
Multi-mode Optical Switch
with Straight Contact
FC/PC Connectors
Page 14 of 16
Laser Safety Information
81613A 1310/1550nm RL
81650A 1310 nm FP
81651A 1550 nm FP
81654A 1310/1550 nm
The laser sources listed directly above are classified as Class 1 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26.
81655A #E01 850 nm FP
81655A 1310 nm FP
81656A 1550 nm FP
81657A 1310/1550 nm FP
81662A C- and L-Band DFB
81663A C-band DFB
81600B #200 1440 nm – 1640 nm All-band TLS
81600B #140 1370 nm – 1495 nm low SSE TLS
81600B #150 1450 nm – 1590 nm low SSE TLS
81600B #160 1495 nm – 1640 nm low SSE TLS
81600B #130 1260 nm – 1375 nm low SSE TLS
81600B #132 1260 nm – 1375 nm high power TLS
81600B #142 1370 nm – 1495 nm high power TLS
81940A 1520 nm – 1630 nm compact TLS
81944A 1525 nm – 1625 nm compact TLS
81949A 1520 nm – 1630 nm compact TLS
81980A 1465 nm – 1575 nm compact TLS
81989A 1465 nm – 1575 nm compact TLS
All laser sources specified directly above are classified as Class 1M according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26.
CLASS 1 LASER PRODUCT(IEC 60825-1 / 2001)
Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage."
Our Promise
Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available.
Your Advantage
Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.
By Internet, phone, or fax, get assistance with all your test & measurement needs
Online assistance:
www.agilent.com/comms/lightwave
Phone or Fax United States:
(tel) 1 800 829 4444 (fax) 1 800 829 4433
Canada:
(tel) 1 877 894 4414 (fax) 1 800 746 4866
Europe:
(tel) +31 20 547 2111 (fax) +31 20 547 2190
Japan:
(tel) 120 421 345 (fax) 120 421 678
Latin America:
(tel) +55 11 4197 3600 (fax) +55 11 4197 3800
Australia:
(tel) 800 629 485 (fax) 800 142 134
Asia Pacific:
(tel) + 852 800 930 871 (fax) + 852 800 908 476
Product specifications and descriptions in this document subject to change without notice. Copyright © 2005 Agilent Technologies September 19, 2005
5988-1571EN
For related literature, please visit:
www.agilent.com/comms/octmainframes