SWIS CAPPING STACK SYSTEM - Oil Spill Response Limited · H4 - 18¾” API HC - 18¾” API Adapter...

Post on 08-May-2020

1 views 0 download

Transcript of SWIS CAPPING STACK SYSTEM - Oil Spill Response Limited · H4 - 18¾” API HC - 18¾” API Adapter...

Oil Spill Response Limited (OSRL) can provide members global access to an integrated intervention system comprising of four capping stacks and two incident response toolkits.

The Capping Stack System: Key Facts• Four capping systems, including two 18¾” 15k stacks and two 7¹⁄₁₆” 10k stacks

(with ancillary equipment) • Transportable by sea and/or air • Available for a variety of international metocean conditions• Designed for subsea use to a maximum of 3000m water depth • Stored in four strategic regional locations around the world – Brazil, Norway, Singapore and South Africa• Manufactured by Trendsetter Engineering

KEY FEATURESStandardised Capping Platform

Outlets with Dual 5 ¹⁄₈”15k Gate Valves

Retrievable Choke

ROV Panel

Lower Connector

Flow Line Connector

Acoustic Transponder

The four capping stacks (both full bore and reduced bore) are designed into a standard configuration with common pipework, valves, chokes and spools all rated to 15kpsi.

The key difference is the use of 7 ¹⁄₁₆” 10k gate valves for the 10k stacks and 18¾“ 15k rams for the 15k stacks.

TECHNICAL INFORMATION SHEET

SWIS CAPPING STACK SYSTEM

Flexible to handle a variety of scenarios

Retrievable chokes to help gain control of a flowing well

15k connectors, adapter and spacer spools

Connects to BOP, flex joint, or top of wellhead

4 x 51/8” outlets on the diverter spool

Diverter spool providing optimal flow path during installation and shut in

Use of Spreader Bar to run the Capping device

Acoustic real-time pressure and temperature data to surface

The 10k System

Outlets with Dual 5 ¹⁄₈”15k Gate Valves

Dual 7 ¹⁄₁₆” 10k Gate Valves

Lower Connector

Flow Line Connector

Retrievable Choke

7 ¹⁄₁₆” 10k API Hub

Acoustic Transponder

ROV Panel

SPECIFICATION

71/16” 10k Capping Device and 183/4” 15k Capping Device

Design Pressure 10 kpsi / 15 kpsi

Design Life 20 years (storage), 6 months (flowing), 2 years (shut)

Water Depth Up to 3000m

Flow Rate 0 to 100 kbd of liquid

GOR 0 to 2000 scf/stb

Design Temp -2°C to 150°C (Operation), -20°C to 40°C (Storage)

CO2 0 to 10%

H2S 0 to 500 ppm

Water Cut Up to 30%

Injection Dispersant and Hydrate Inhibitor (150 L/min)

Outlets 4 outlets, each with dual

5¹⁄₈” Gate Valves

Sealing Device 10k Stack: 2 x 7¹⁄₁₆” Gate Valve (fail as is)/ 15k Stack: 2 x 18¾” Rams

Operation Third-Party ROV (manual and hydraulic)

Measurements Pressure and Temperature

Connectors H4 and HC 18¾” 15kpsi

Adapter spools H4 and HC 18¾” by 18¾” 15 kpsi API flange

Flow Control Retrievable Choke Valve on each outlet

Installation Drill Pipe and / Method or Wire Line

Transportability Air, Land and Sea

Material NACE MR-0175 Zone 3

The 15k System

18¾” Dual 15k Rams

Lower Connector

Flow Line Connector

Retrievable Choke

H4 Mandrel

Acoustic Transponder

Outlets with Dual 5 ¹⁄₈”15k Gate Valves

ROV Panel

Oil Spill Response LtdLower William StreetSouthampton SO14 5QEUnited KingdomT: +44 (0)23 8033 1551F: +44 (0)23 8033 1972E: subseaservices@oilspillresponse.comwww.oilspillresponse.comwww.swis-oilspillresponse.com

Ancillary EquipmentConnectors Spacer Spools

HC Connector H4 Connector

H4 Weldneck

H4 - 18¾” API

HC - 18¾” API

Adapter Spools

3m 2m 1m

Lifting Eye

Accumulator Racks (40 Bottles x 15 Gallons)

H4 Test Stump

HC Test Stump

Test Stand

18¾” API 15k blind flange Connector Parking

Stands

JULY

201

4