Post on 06-Jul-2018
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 1/368
ROC L7 , L7 CR, L8 , L6 with Bosal cabin
40 40 30 30
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 2/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 3/368
Subject Content Tab
ROC L Hydraulics, general 1
Electrics, general 2
Operating 3
CAN general 4
Diesel engine 5
Pumps & pilot pressure; Cooling fans 6
Tramming; Positioning 7
Compressor8
Pre-heating 9
Feed 10
Rotation 11
Rapid feed; Rod coupling 12
Impact & Flushing air; ECL/HECL 13
Damper 14
DCT 15
Protective functions 16
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 4/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 5/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 6/368
O C L M k 2 C o n t e n t v 1 .
d o c
2
L 7 4 0 C R , L 8 3 0
[ M o n
d a y ]
M e t h o d
/ A c t i v
i t y
M a t e r i a
l , C o u r s e
l e a d e r
T i m e
A p .
l o f t h e t r a i n i n g
th e
t r a i n i n g m a t e r i a l
•
H a n d o u t : M a n u a
l , C o u r s e a n d w r i t i n g m a t e r i a l
t o s t u d e n t s .
•
P r e s e n t c o u r s e
l e a d e r a n d p a r t i c i p a n
t s .
•
P r e s e n t c o u r s e g o a l .
•
C o n t e n t a n d
t h e p r a c t i c a l a r r a n g e m e n t s .
tic i p a n t s ’ k n o w l e d g e o f •
F a c t o r y
t o u r a n d c l a s s r o o m
t a l k a b o u t o u r
p r o d u c t s .
r e a d a n d u n d e r s t a n d
•
S h o w a n d e x p l a i n
t h e d i f f e r e n t s y m b o l s a t
d r a w i n g .
•
S h o w t h e s y s t e m
i n r e a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
r e a d a n d u n d e r s t a n d
•
S h o w a n d e x p l a i n
t h e d i f f e r e n t s y m b o l s a t
d r a w i n g .
P o w e r p o
i n t p r e s e n t a t i o n
c o m p o n e n t s a n d
k s a r e
l o c a t e d
•
S h o w p i c t u r e s a n d a t r i g
P o w e r p o
i n t p r e s e n t a t i o n , R i g
c i p l e o f t h e
C a n B
u s
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
n u h a n d l i n g
•
S h o w b y u s e
o f s i m u l a t o r a n d
l e t p a r t i c i p a n t s
u s e s i m u l a t o r
S i m u l a t o r s o f t w a r e
c i p l e o f t h e
P L C a n d
h e P L C e x p l a n a t i o n
•
S h o w d r a w i n g s ,
P L C e x p l a n a t i o n a n
d p r a c t i c a l
a t r i g
S c h e d u l e s ,
P L C e x p l a n a t i o n
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 7/368
O C L M k 2 C o n t e n t v 1 .
d o c
3
7 4 0 , L
7 4 0 C R
, L 8 3 0
[ T u e s
d a y ,
W e d n e s d a y ]
M e t h o d
/ A c t i v
i t y
M a t e r i a
l , C o u r s e
l e a d e r
T i m e
A p .
c t i o n o f t h e
d i f f e r e n t
rs a n d s w
i t c h e s
•
S h o w p i c t u r e s a n d a t r i g
P o w e r p o
i n t p r e s e n t a t i o n , R i g
i c p r i n c i p l e o f s t a r t
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
r e s e n t a t i o n
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n a n d c o n t r o l o f
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n a n d
l o c a t i o n o f
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
t r a m m i n g
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e p o s i t i o n i n g •
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
y s t e m
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
lli n g p r i n c i p l e
•
S h o w h o w d r i l l i n g
i s d o n e w
i t h t h e n e w
j o y s t i c k .
c t i o n o f t h e
f e e d
e r a p i d s t o p s y s t e m
e H E C 3 p r o g r a m
a l i b r a t e o f B
1 7 2
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
S y s t e m d e s c r i p t i o n
c t i o n o f t h e r o t a t i o n
&
t e m
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
i m p a c
t &
s t e m
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
l u b r i c a t e
h o w t o s e t t h e m i n
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 8/368
O C L M k 2 C o n t e n t v 1 .
d o c
4
7 4 0 , L
7 4 0 C R
, L 8 3 0
[ T h u r s d a y ]
M e t h o d
/ A c t
i v i t y
M a t e r i a
l , C o u r s e
l e a d e r
T i m e
A p .
c t i o n o f t h e
D a m p e r
&
t e m
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
D C T
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
R p c - f
4 0 .
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e a n t i -
te m
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
l e n g t h
t s y s t e m
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
R H S 5 1
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n o f t h e
R H S 8 9
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
P o w e r p o
i n t p r e s e n t a t i o n
c t i o n a n d
h o w t o u s e
s y s t e m
•
S h o w o p e r a t o r s m a n u a l a n d p r a c t i c a
l a t r i g
c t i o n o f E x t r a c t o r ,
s t e m , g r e a s e / s p r
a y
L a s e r s e n s o r
•
S h o w d r a w i n g s a n d c h e c k p r a c t i c a l a t r i g
S y s t e m d e s c r i p t i o n
fe t y i n s t r u c t i o n s
•
S h o w t h e o p e r a t o r ’ s m a n u a l a n d s a f e t y c h a p t e r
O p e r a t o r
’ s m a n u a l
o r t a n t o f m a i n t e n a n c e •
S h o w t h e o p e r a t o r ’ s m a n u a l a n d
t h e
m a i n t e n a n c e
c h a p t e r
O p e r a t o r
’ s m a n u a l
u s e t h i s t o o l
•
S h o w h o w t o
f i n d p a r t s
i n t h e p r o g r a m
A c t i V
i e w p r o g r a m
2 0 q u e s t i o n s
t o c h e c k
t s k n o w l e d g e o n
t h e
•
T e s t o f 2 0 q u e s t i o n s
L 7 4 0
, L 7 4 0 C R
, L 8 3 0
[ F r i d a y ]
M e t h o d
/ A c t
i v i t y
M a t e r i a
l , C o u r s e
l e a d e r
T i m e
A p .
c t i o n a n d s y s t e m o f
•
H a l f d a y a t R o c k t e c .
I n f o r m a t i o n o n
4 0 5 0 H E
,
C E
, C R
tr a i n i n g
•
Q u e s t i o n n a i r e
e r i g a n d
d o s o m e
rk
•
P r a c t i c a l d r i l
l i n g w
i t h L R
4 0 C R
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 9/368
Hydraulic system, general
Hydraulic system, general
General – L7 40 , L7 40CRThe hydraulic system of the ROC L7 40 and L7 40CR is an electrical and pilot pressurecontrolled system, with 6 hydraulic pumps. Hydraulic pumps 1, 2, 3 and 4 are in-lineassembled and direct driven by the diesel engine over a flexible coupling.The hydraulic pumps 5 and 6 are combined to a double pump with a common suction line.They are driven by the diesel engines extra power-take-off.
The pressure on these pumps is regulated with fixed or variable pressure relief valves. Pump 1is an axial piston pump with variable displacement. During drilling pump 1 is regulated by thepressure relief valves for high/low percussion. During tramming pump 1 is connected to twoflow sharing compensated directional control valves. The pump pressure is controlled bywhichever load there is on the tramming motors.
Rapidfeed
RotationPreheating
Drillfeed
Main valve blockLogicValves
Impact
Postioning during trammingExtra oil to rotation
3
Tramming control via PLC
Electrical valves:Drilling
Tractionleft
Tractionright
1
PressureControl
2
Dust Collector
5 64
RodHandling
GaugesPanel &
Extra oil only when drilling
Postioning
during drilling
Cooler motorEngine water/ATAC
Cooler motorCompressor/Hydraulic oil
9
RPCF
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 10/368
Hydraulic system, general
General – L8 30 The hydraulic system of the ROC L8 30 is an electrical and pilot pressure controlled system,with 6 hydraulic pumps. Hydraulic pumps 1, 2, 3 and 4 are in-line assembled and directdriven by the diesel engine over a flexible coupling.The hydraulic pumps 5 and 6 are combined to a double pump with a common suction line.They are driven by the diesel engines extra power-take-off.The pressure on these pumps is regulated with fixed or variable pressure relief valves. Pump 1is an axial piston pump with variable displacement. During drilling pump 1 operates on
constant pressure. During tramming pump 1 is connected to two flow sharing compensateddirectional control valves. The pump pressure is controlled by whichever load there is on thetramming motors.
Rapidfeed
RotationPreheating
Drillfeed
Main valve blockLogicValves
Cooler motorCompressor/Hydraulic oil
3
Tramming control via PLC
Electrical valves:Drilling
Tractionleft
Tractionright
1
PressureControl
2
Dust Collector
5 64
Cooler motorEngine water/ATAC
Rodhandling
GaugesPanel &
Extra oil only when drilling
Extra oil to rotationPostioning during tramming
Postioningduring drilling
9
L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 11/368
Hydraulic system, general
Hydraulic pumps
Figure: Test connections for checking the hydraulic circuits.
Pump 1The main pump 1 in the hydraulic system is an axial piston pump.The pump supplies hydraulic power to the following functions:
L7 40 L7 40CR L8 30 • Rock drill impact • Rock drill feed • Rock drill damper • Rock drill stroke position • Positioning • Rod handling• Tramming •
Pilot pressure • Hydraulic jack • Service winch • Track oscillation
• Rock drill impact • Rock drill feed • Rock drill damper • Rock drill stroke position • Positioning • Rod handling• Tramming •
Pilot pressure • Hydraulic jack • Service winch • Track oscillation
• Rock drill feed • Positioning • Rod handling• Tramming • Pilot pressure • Hydraulic jack • Service winch •
Track oscillation
Pump 2 3 and 4
L7 40 L7 CR, L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 12/368
Hydraulic system, general
Pump capacitiesRig type L7 40 L7 40CR L8 30 Rpm @ 2000 rpm engine speed @ 2000 rpm engine speed @ 1800 rpm engine speed
Flow(l/min) P (bar, max.) Flow(l/min) P (bar, max.) Flow(l/min) P (bar, max.)Pump 1Pump 2Pump 3Pump 4Pump 5Pump 6
275115653530/*4530/*45
250170170250210/*225210/*225
260115653530/*4530/*45
250170170250190/*225190/*225
235110654032/*4532/*45
250170170250190/*225190/*225
*Higher figure refer to the 55 °C ambient temperature option.
Pilot pressureThe pilot pressure signals from the drill lever are transferred to the main valve block and tothe pressure control panel via logic valves. The pressure gauge panel shows the impactpressure, feed pressure and rotation pressure in the main valve block. The pressure control
panel controls the working pressure of pump 1 (only in L740
& L740
CR), feed and the rotationfunctions in the main valve block. The gauges & panel are located in the cab for easy use.
The tramming controls are mounted close to the operator’s seat, and control the maintramming valves proportionally.
Return oil and oil coolerThe hydraulic oil tank has a capacity of 410 litres, which means there is often a “stock” ofoil in the tank. There are two return-/drain oil filters that filter the hydraulic oil from thereturn- and drain circuits and oil used to fill the system. There is also a breather filter thatprevents contaminated air entering the tank when the level of hydraulic oil fluctuates. Thethermostats ensure that the oil flows through the oil cooler when the temperature is above40ºC and directly to the tank when the temperature is below 40ºC. The by-pass valve protectsthe oil cooler from exposing to high pressure.
The oil cooler cools the hydraulic oil so that the rig can work at full load in ambienttemperatures up to 55°C (optional). The cooling fan is driven by a fan motor that is suppliedwith oil by pump 5. The pressure to the fan motor is controlled by a proportional pressurerelief valve. The control system regulates the pressure, and thereby the fan speed dependingon the cooling demands.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 13/368
Hydraulic system, general
The temperature sensor (B362 ) senses the hydraulic oil temperature and the temperature
will be shown on the display. The engine will shut down automatically if the hydraulic oiltemperature exceeds 90ºC . The sensor signal from B362 goes via PLC input X16-5 .
The drain cock is used to remove water of condensation or to empty the hydraulic oil tank.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 14/368
1
Hydraulic system L7TH, CR
Hydraulic system L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 15/368
Electrical system, general
Electrical system, general
GeneralROC L7 40 , L7 40CR, L8 30 are equipped with a 24-volt electrical system for monitoring andfault indication, electric power is also used for controlling a number of hydraulic andpneumatic valves. The composition of the electrical system is illustrated in the block diagram.
Battery charging
Power supply to the electrical system consists of two, serie-connected 12 volt / 185 Ahbatteries. These are charged by a 3-phase A/C alternator. The batteries are connected to thesystem by a manually operated battery switch.
Main fuseThe feed to the electrical cabinet is fused by a 63 A main fuse (F100).
Electrical cabinetThe electrical cabinet A1 contains 34 ATO fuses (when all options are included) that limit thecurrent intensity to the different sub-circuits, two auxiliary relays (K18, K178) to handle largecurrents above 4 Amp, stop relay for the emergency stop circuit (K11), remote shutdownrelay (K200), start relay (K5A), main fuse and a PLC (CPU1-3).
ECM (Caterpillar)Electronic Control Module is used for monitoring the engine’s functions and sensors. Itreceives analogue and digital information from the engine. The information is processed andtransferred in J1939 protocol. The ECM stops the diesel engine automatically if a specificfault occurs. A specific fault is for example low oil pressure which could cause major damageto the engine.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 16/368
Electrical system, general
Electrical supply
Ignitionposition
Startposition
CAN nodes
D550,551, 552, 553, 554
K11
K5A
E-stops
M1starter motor
ECM
Startengine
Radio, cabinlights, utility light
PLC
outputs &relays
One of theconditions toactivate K5A
5 0
c i r
c u
i t
2 5
c i r
c u
i t
15 circuit
PLC
processor& sensorinputs
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 17/368
Electrical system, general
The power source consists of two 12V/185Ah batteries connected in series and an alternator.
Before the main switch is switched on, there is power to the diesel fire heater & timer.When the main switch is switched on, there is power supply to the radio, cabin lights, utilitylights and ECM (48,52,53) thorough teminals 10 and 25. Power is also supplied to the startermotor switch, but the switch is triggered by the starter motor relay via PLC.
When the key is in the ignition position power is supplied to the emergency stop circuit,CAN nodes, display, PLC processor and its sensor inputs through terminal 15. If theemergency stops are intact, relay K11 is activated. Power is now supplied to the ECM (70),PLC outputs and relays, working lights/wiper, seat heating and the climate system in the cabinthrough terminal 50.
When the key is in the start position the diesel engine is started via starter motor M1 , andstarter motor is powered by relay K5A . K5A is activated if the conditions for starter motor arefulfilled.
ECM is supplied with power both before and after ignition. The difference is, before ignition,ECM is powered to boot its memory, but its monitoring functions are not started at this level.Only after the key is in the ignition position, ECM starts working properly.
If any of the emergency stops is activated, it will deactivate switch K11 , causing all thefunctions at the ignition level except the CAN nodes, display and CPU processor & sensorinputs to be without power, since they are connected parallel with the emergency stop circuit.Turn the key back to 0 position before re-start.
Note : The electrical system’s ground cables are not isolated by the main switch. This meansthat the system consumes a small current even when no functions are activated.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 18/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 19/368
2
Electrical system, overview
MAIN ELECTRICAL CABINET
Main fuse ATO-fuses
BatteriesMain battery
switch
M12-boxes
Inputs
PLCProgrammable logic control
Outputs
SensorCompressor
SensorHyd. oil level
SensorsRod handling
SensorHyd. oil temp
SensorAir filters
Hyd. valvesRod handling
Hyd. valvesFeed
Hyd. valvesAnti-jamming
Air valvesImpact/Fl. air Dust collector
ECL&(HECL)Pumps
Drilling panel (right)
Pre-heating
Switches SwitchesTramming
Enginespeed
Trackoscillation
Compressorload
Drilling panel (left)
Flush air
SwitchesDust collector
Drill steelsupport
SwitchesTramming
Joy-stickRod handling
Break outtable
Suctionhood
ECMCat Electronic Control Module
SensorsDiesel engineEngine stop
Ignition keyStart motor
Drill lever
CPU 1-3 Cabinmodules
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 20/368
3
Electrical cabinet X1
Terminal 50
See page 7
Refer to page6 coordinates3E
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 21/368
4
3
E
Frompreviouspage:coordinates3E, page 6
Contact
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 22/368
5
Indicator card no.
Terminal 8
1
2
Distribution box X36,Contact 7, signal 2 (S2)
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 23/368
6
2
1
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 24/368
7
Electrical cabinet
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 25/368
14
Overview – rig right side
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 26/368
15
Overview – rig left side
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 27/368
1
Operating Cabin heat and AC
1. Working lights cab, front2. Working lights rig, rear3. Working lights feeder
4. Lighting engine c ompartment5. Windscreen washer, upper
6. Windscreen wiper, upper increases speed in steps.7. Windscreen wiper, upper reduces speed in steps. Switch off
by depressing and holding the button for 2 seconds.8. Front windscreen washers
9. Windscreen wiper, front reduces speed in steps. Switch off bydepressing and holding the button for 2 seconds.
10. Windscreen wiper, front increases speed in steps.11. Windscreen wiper, right reduces speed in steps. Switch off
by depressing and holding the button for 2 seconds.12. Windscreen wiper, right increases speed in steps.
13. Windscreen washer, right14. Seat heating in two steps
15. Air condition16. Fan, air conditioning reduces speed in steps.
17. Fan, air conditioning increases speed in steps.
18. Temperature reduces the temperature.19. Temperature increases the temperature.
20. Fan, heater increases speed in steps.21. Fan, heater reduces speed in steps.
22. Not used23. Not used
Operating
ROC L7 40
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 28/368
3
Operating
ROC L7 40CR
Operating
ROC L8 30
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 29/368
5
Operating Drill control panel
S139 Ignition keyS130 Switch for drilling/tramming/oil heating
S170 Not used on ROC LS448 Water mist.S209 Support leg.S186 Signal horn
S449 Thread greasing.S176 Track oscillation, (left).
S445 Track oscillation (locking).S177 Track oscillation, (right).
S180 Compressor.S189 Rpm control (variable).
S130
a: Drillingb: Tramming low speedc: Tramming high speed
d: Oil pre-heating.
Operating
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 30/368
7
Operating
Operating
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 31/368
9
Operating
1. Drill feed pressure2. Flushing air pressure
3. Rock drill lubrication pressure,ECL(L7), HECL (L6, L8)4. Return pressure filter
5. Rotation pressure6. Percussion pressure
7. Damper pressure
Operating
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 32/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 33/368
CAN, general
CAN, generalThis is an overview of the CAN communicationnetwork. If communication is down in any ofthe units, the unit will show in red, and awarning for communication breakdown will beshown on the status bar.
CANThere are various types of control modules (PLC, ECM, main display, CAN nodes etc.).Common to all of these is that they each contain a separate processor. The modulescommunicate with each other over a CAN bus. The CAN bus uses serial communication. Onepiece of data at a time is sent over the bus until allthe data has been transmitted. This is a simplemethod that requires only 4 conductors (CAN+,CAN-, CAN high, CAN low) and a screen. TheCAN network is supplied with 24 V, and the CANhigh / low signal lies at approximately 2.6 V and2.4 V respectively.
Display D501All CAN data is handled by the display shown graphically or digitally. The program for theHEC (Hole/Engine Control) system is stored in the display and the software is downloadedvia a PC or a USB-flash drive (see installation instructions in a separate section).
The display shows engine data, angle/hole information and the status of switches/sensors, etc.CPU2 receives the information sent from ECM in J1939 protocol and translates this toCANopen protocol, which is then shown on the display. Other information is sent directlyfrom the CPUs, CAN nodes, D169 module and D171 module to the display by usingCANopen protocol.
PLCThe PLC system consists of three CPU units (CPU1 CPU2 CPU3) They are each
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 34/368
CAN, general
CAN nodes
The CAN nodes (D550, D551, D552, D553, D554) translate all the input signals for all theswitches located on the operating panels; also the output signals for all the leds and magnetslocated in the drill lever, so the modules can communicate in CAN “high”/“low” signalsdirectly. Every input/output on the CAN nodes each has its own led. The led will light inconstant yellow when their corresponding input/output is activated.
There are also two CAN communication leds on every CAN node, one lights in green and theother one lights in red. A green stable signal indicates the CAN node is in its preoperationalmode; a green blinking signal indicates that the CAN node is in operation, but both signalscan not indicate whether the CAN node is correctly installed to match the CAN Node IDnumber shown in the display. The CAN node ID number has to be set manually on themodule when installed. When a communication fault occurs during operation, the red led willbe activated.
ECM
CAT’s engine control module that controls engine operation.
D169/D171/D173 ModuleD169 module is a CAN-based aiming device that communicates with the display directly.D171 module is a CAN-based angle sensor that communicates with the display directly.D173 module (option) is a CAN-based GPS compass that communicates with the displaydirectly.
Terminal plugAt the start and end of the CAN network there are terminal plugs installed. A terminal plugconsists of a resistor (120 Ω ) which terminates the network’s both ends in the correct way sothat the signal does not “bounce back to the system”. There are 4 terminal plugs installed inthe CAN network (see figure below).
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 35/368
CAN, general
CAN system overview
Ignition
J1939
D169
D173option
D171
End plug
CAN +/-CAN H/L
X1
X3
X2
End plugX4
X5 X6
ESC
F1
F2
F3
F4
RIG CONTROL SYSTEM
D501
D552
D553
D551
D550
D554
X7
1 5
c i r
c u
i t
F23
1 5
c i r
c u
i t
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 36/368
CAN, general
Sensor/switch monitoring system
The CAN system can present switch and sensor status on the display screen. The analoguesensors are connected via the CPUs, except potentiometer R189 (adjusting engine revolution)is connected via the CAN node and the coolant water level sensor B361 is connected directlyto the ECM, though sensor B361 is powered from external power source (M12 box X34:8).
The digital (ON/OFF) switches are connected via the CAN nodes, and the digital sensors areconnected via the CPUs, except sensor B379 (operator in chair) is connected via CAN node.
By selecting a module with the curse on the screen, and press the enter button, status of eachmodule could be checked (in the event of a red module).
By selecting in/outputs for the CPUs or the CAN nodes modules on the screen, status for allinputs and outputs could be checked in the system. An actuated function is displayed as “1”while and un-actuated function is displayed as “0”.
Note that for an input, “0” or “1” is the status that is received by the CPUs; while “0” and “1”for an output is the signal sent from the CPUs. I.e. there is not any confirmation that the signalactually is received by the valve, etc. Broken cables are not noticed by the system.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 37/368
Control panel
Control panelThe control panel is comprised of a touch panel user interface and a powerboard for function actuation.
Before ignition, the power board is powered with 24 V via fuse F25, thebutton for light in engine compartment and the indication lamp for batterystart to blink in green.
After ignition, the power board is powered with 24 V via fuses F4, F5 andF10, and the power board is lit up in white.
A CAN cable is used as the communication media between the power boardto the touch panel; also used to power up the touch panel. This CANnetwork exists as a separate circuit, aside from the CAN network mentionedin the chapter before.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 38/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 39/368
Diesel engine
Diesel engine
The engine on ROC L740
, L740
CR is a turbocharged, water cooled C13 diesel engine fromCaterpillar. Rated power at 2000 rpm is 328 kW.The engine on L8 30 is a turbocharged, water cooled C15 diesel engine from Caterpillar. Ratedpower at 2000 rpm is 402 kW.
Battery switch, OFFThe diesel fire heater and the timer are connected before the battery switch S300 via fusesF02 and F03 . The generator G2 (B+) is connected directly to the batteries.
Battery switch, ONWhen the battery switch S300 is switched on there is 24V to:• Utility lights in engine compartment, cabin
lights, instrumental lights, radio and cellphone outlets via fuse F25 , F26 in A1cabinet.
• ECM is also powered via fuse F25 , but thecommunication between ECM and rest ofthe system has not yet started.
Ignition positionWhen the ignition key S139 is in the ignition position the contacts 30-15 and 30-75 are
closed. The ignition relay K11 is activated and the relay contacts are closed under theconditions that the emergency stops are intact.
Before the K11 relay contacts are closed, the display and the emergency stop circuit aresupplied with voltage via fuse F25 . PLC processor and sensor inputs are supplied withvoltage via fuse F14 ; CAN nodes are supplied with voltage via fuse F23 .
When the K11 relay contacts are closed, the ECM is supplied with voltage via fuse F13 , ECMis now functional. PLC outputs and relays are supplied with voltage via F15-F22 .
ROCS300 S300
ON OFF
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 40/368
Diesel engine
Start position
Conditions for activation of starter motor:• Emergency stops S132A and S132B not activated => PLC input X10-8/ON • Fuses F100 , F3 , F13 , F14 , F15 , F23 are intact.• S130 in tramming mode => D552-CH2 or CH3/ON • Compressor switch S180 OFF => D552-CH9/OFF • Ignition key S139 in start position => D550-CH4/ON • Only for L8 30 : Start preventing pressure sensor B336 OFF => PLC input X13-4/OFF
When all the above conditions are met, this will result in:• Start relay K5A is activated and the relay contact is closed, hence activating starter motor M1 ,
i.e. engine is cranking.
Conditions for starting the diesel engine:• Compressor temperature B366 < 120°C (~17.5mA).• Hydraulic oil level sensor B143 activated, which indicates the oil level is normal.• Hydraulic oil temperature B362 < 90°C (~15mA). If the conditions above are fulfilled:• K200 activated, enables engine start.
When the ignition key S139 is turned to the start position and the engine fails to start, checkwhich symbol(s) are displayed and rectify the fault. Turn the key back to position 0 beforetrying again.
ECM overviewECM is functional when the battery isswitched (1) and the ignition key is position(2). To start the diesel engine, K200 has to beactivated (3) so ECM 44 is not grounded(refer to page 15 for more information onautomatic engine shut-down), and theCaterpillar sensors (4) must be workingnormally.
Loss of condition 3 and 4 automatically shutsdown the engine.
PLC
ECM
2 3
e-stop
keyS139
Remote shut down
Ignition key switched
Battery ON
(ECM 44)
K200
Di l i
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 41/368
Diesel engine
Engine speed
The engine speed can be de- or increased by flicking switch S189 up- or downwards. Digital signal is sent directly into the CANnode D554, then to CPU2 through CAN open protocol, and at lastsent to the ECM through J1939 protocol.
CPU2 can support 7 engine revolutions, and it can store 3 separateengine speeds, one for tramming, one for rod handling and one fordrilling. CPU2 remembers the engine speeds for rod handing and
drilling even when the battery switch is turned off. In trammingmode the system will always start at 1200 rpm. The speeds can allbe set individually within the range specified below.
Condition for revolution between 1200-2000 Tramming modeSwitch S130 NOT in drilling position
Condition for revolution between 1500-2000 RHS modeSwitch S130 in drilling position and reduced flushing air NOT activated (Y116/OFF)
Condition for revolution between 1700-2000 Drill modeSwitch S130 in drilling position and reduced flushing air activated (Y116/ON)
The engine starts on idling speed 1200 rpm, flicking the switch once upwards should increasethe speed to 1500 rpm, then the engine speed increases with 100 rpm per flick upwards until it
reaches the maximum speed of 2000 rpm. It is also possible to hold the switch for severalseconds in order to reach the maximum speed. To decrease the engine speed from the idlingspeed, flick the switch once downwards takes down the speed step by step just like upwards.When changing from tramming position to drilling, the engine speed automatically increasesto engine speed set for drilling and vice versa.
a
b
c
ab c
d
Di l gi
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 42/368
Diesel engine
Control instrumentation
The ECM controls and monitors all engine data and diagnostic information from the dieselengine. This information is sent via CPU2 to the display, where all the necessary engineinformation is presented. CPU2 also translates the information from J1939 to CAN open so itcan be presented on the display.
Signals from the rig sensors are sent via the CPUs directly to the display, where informationcan be viewed. (See figure)
A red warning lamp on the status bar meansthat the problem is critical, and the enginewill be shut automatically. A yellow warninglamp means the engine needs to be switchedoff manually, and the fault needs to bechecked and rectified. Refer to “Switchesand sensors that automatically and manuallystop the diesel engine” for a list of sensorsthat automatically and manually shut downthe engine.
Engine monitoring A number of sensors and switches on the engine do not generate warnings on the status bar inthe event of a fault. A direct code system has been introduced, this allows you to go directly
to the CAT fault diagnosis table to interpret the codes. The table will only present informationwhen a fault arises. The ECM or the engine sensor symbol on the status bars indicates that afault has been detected. This can be found in the menu for ECM sensors. The fault isdisplayed as a 3 digit SPN code and 2 digit FMI code. (See figure)
Status bar
Diesel engine
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 43/368
Diesel engine
Switches and sensors that automatically and manually stop the dieselengineAutomatically stopping (or shutting down) the diesel engine does not mean that the wholesystem also goes off. All functions at the key ignition level are still working. To shut downthe whole system including the display, turn the key back to the 0 position.
Manual:
• Start key (S139) • Emergency stop (S132A, S132B)
Automatic:
These are indicated by a red lamp on the status bar and switch the engine off automatically.
• Hydraulic oil level (B143)
The level switch sends a signal to PLC input X11-8 when the level is normal. If the level isbelow normal, the loss of X11-8 will result in a loss of PLC output X11-3 which is connectedto relay K200 . ECM 44 gets grounded and shuts down the engine.
• Hydraulic oil temperature (B362)The temperature sensor sends a signal to PLC input X16-5. If the temperature has reached80°C, a yellow warning is shown first, and if the temperature has reached 90°C, this willresult in a loss of PLC output X11-3 which is connected to relay K200 . ECM 44 getsgrounded and shuts down the engine.
• Compressor temperature (B366)The temperature sensor sends a signal to PLC input X16-7 and PLC input X16-6 (for DTHrigs). If the temperature has reached 117°C, a yellow warning is shown first, and if thetemperature has reached 120°C, this will result in a loss of PLC output X11-3 which isconnected to relay K200 . ECM 44 gets grounded and shuts down the engine.
• Engine oil pressure (B353)The engine oil pressure sensor is part of the Caterpillar system and connected to the ECM.Should abnormal pressure occur, the ECM shuts the engine down and a warning is shown onthe status bar.
Diesel engine
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 44/368
Diesel engine
Switches and sensors that only indicate a fault•
Compressor air filter (B365)Connected to PLC input X13-8.
• Engine air filter (B360)Connected to PLC input X13-7.
• Fuel temperatureThe engine fuel temperature sensor is part of the Capterpillar system and connected to theECM. Should the fuel temperature reach 80°C, a warning is shown on the status bar.
• Battery voltageShould the battery voltage fall below 24 V, a warning is shown on the status bar.
• Air inlet temperatureThe inlet air temperature sensor is part of the Caterpillar system and connected to the ECM.
Should the temperature reach 75°C, a warning is shown on the status bar.
Diesel engine
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 45/368
Diesel engine
Warning symbol related to the engine
Symbols AC designation Description Yellow sign stage Red sign stage
B353 Engine oil pressure Too low pressure
B361 Engine water level Too low level
B143 Hydraulic oil level Too low level
B354 Engine coolanttemperature
105°C
B366 Compressor
temperature
117°C 120°C
B362 Hydraulic oiltemperature
80°C 90°C
B360 Engine air filter Plugged filter
B365 Compressor air filter Plugged filter
Fuel temperature 80°C
Battery voltage < 24 V
Air inlet temperature 75°C
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 46/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 47/368
1
Main switch OFF
S300
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 48/368
2
Main switch ON 1
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 49/368
3
Utility light
Radio24 V outlet
Cabin control panel
Main switch ON 2
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 50/368
4
+ battery(unswitched)
Main switch ON 3
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 51/368
5
Key in ignition pos. 1
Main switch on/25 circuitKey in ignition pos.but before emergency stops/15 circuitGround connection
K11
To D550
To M1
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 52/368
6
Main switch on/25 circuitKey in ignition pos./50 circuitGround connection
F100
Key in ignition pos. 2
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 53/368
7
Main switch on/25 circuitKey in ignition pos./50 circuitGround connection
Cabincontrolpanel
Key in ignition pos. 3
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 54/368
8
+ battery(switched)+ battery
(unswitched)
Main switch on/25 circuitKey in ignition pos./50 circuitGround connection Key in ignition pos. 4
S139
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 55/368
9
Starter motor conditions 1
Main switch on/25 circuitKey in ignition pos.but before emergency stops/15 circuitKey in start pos.Ground connection
S132A S132B
Basic conditions on fuses:Fuses F100 , F3 , F13 , F14 , F15 , F23 are intact.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 56/368
10
S130CH2 or CH3
24V input
Starter motor conditions 2
S180
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 57/368
11
24V input
CH9 OFF
Starter motor conditions 3
L830 only
24V input
B336X13-4 OFF
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 58/368
12
24V outputGround connection
K5
K5 needs to be activated in order to activate cranking.
Starter motor conditions 4
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 59/368
13
Main switch on/25 circuitKey in ignition pos./50 circuitGround connection
K5
From F2,page 4
M1 Engine cranking
Starter motor conditions 5
B143
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 60/368
14
Engine start condition
24V supplyInput signal
B362
B366A
B366B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 61/368
15
24V outputGround connection
K200
K200 gets activated when all the required sensors(B143, B362, B366) are working normally.
Engine started 1
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 62/368
16
Main switch on/25 circuitKey in ignition pos./50 circuitGround connection
K200
ECM 44 not grounded,enables engine start.
Engine started 2
Pumps & Pilot Pressure
Pumps & Pilot Pressure
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 63/368
Pumps & Pilot Pressure
Pump 1 – L740
, L740
CRPump 1 is the main pump in the hydraulic system of ROC L7 40 , L7 40CR. It is an axial pistonpump with a variable displacement. The pump is pressure compensated, which means that thepressure is maintained constant irrespective of the flow.The pump pressure can be controlled by either pressure relief valves connected to the controlpanel when impact is started, or by pressure control valve 4d .
Pressure relief valves in the control panel – L7 40 , L7 40CRDuring drilling, pump 1 pressure is controlledby two pressure relief valves ( 47e & 47f ) forhigh and low impact. These are connected to thepump control system when impact valve Y101A is activated. When impact is not switched on,pump 1 operates on constant pressure set bypressure relief valve 4d + the Delta-p presetpressure.
Pressure control valve “4d” – L7 40 ,L7 40CRDuring tramming, pump 1 is working in loadsensing mode, which means that the pumppressure depends on the load on the tramming
motors. The maximum pressure of pump 1 canbe adjusted by pressure relief valve 4d .
“P max” valve – L7 40 , L7 40CRThe “P max” valve located on the pump limits the maximum pump output pressure, but thispressure would not be reached since pressure relief valve 4d which is set to be lower than “P
” i th t li it th t V l 4d h ld b d h dj ti g th
Drilling mode(constant pressure)
Impact ON Impact OFF
Tramming mode(varying pressure)
Pressure relief valves47e & 47f control pump1 pressure
Pressure control valve4d + ∆ p set pump 1pressure
Max pressure limited by pressurecontrol valve 4d + ∆ p
Pumps & Pilot Pressure
Pump 1 – L8 30
L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 64/368
Pump 1 L8 Pump 1 is the main pump in the hydraulic system of ROC L8 30 . It is an axial piston pump
with a variable displacement. The pump is pressure compensated, which means that thepressure is maintained constant irrespective of the flow.The pump pressure can be controlled by pressure control valve 4d .
Pressure control valve “4d” – L8 30 During tramming, pump 1 is working in loadsensing mode, which means that the pumppressure depends on the load on the trammingmotors. The maximum pressure of pump 1 canbe adjusted by pressure relief valve 4d .During drilling, pump 1 operates on constantpressure set by pressure relief valve 4d + theDelta-p preset pressure.
“P max” valve – L8 30
The “P max” valve located on the pump limitsthe maximum pump output pressure, but thispressure would not be reached since pressurerelief valve 4d which is set to be lower than “Pmax”, is there to limit the system pressure. Valve 4d should be used when adjusting the pump1 working pressure within the system. “P max” is set to be higher than “4d” by factorysetting, so it’s usually not necessary to changethe setting on “P max”, this way “P max” wouldnot interfere with the LS signal.
In order to avoid start the diesel engine with pump 1 pressurized, the Drilling/Trammingswitch must be in the Tramming position when starting. In this position, pump 1 runs atstandby pressure, 23 bar. Starting with the switch in Drilling position is also electricallyblocked.
Pumps & Pilot Pressure
Pump 1 pressure settings
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 65/368
Pump 1 pressure settings• Checking / Setting the stand-by pressure “Delta-p”.1. Start the engine and set the engine speed to 1500 rpm.2. Move the switch Drilling/Tramming to position Tramming.3. Make sure no functions are activated, so the rig stands still.4. Pressure gauge 34 connected to pump 1 pressure line should
show 23 bar.5. Adjust the “Delta-p” set screw on the pump regulator if
necessary.
• Checking / Setting the pressure relief valve “4d”.1. Start the engine and set the engine speed to 1500 rpm.2. Move the switch Drilling/Tramming to position Drilling.3. Make sure no functions are activated. (Especially important for L7 40 and L7 40CR)4. The reading from gauge 34 should be 250 bar (LS return pressure + delta-p). If not, adjust
the screw on 4d until the gauge reads 250 bar. Note : If it happens that the reading is lower than 250 bar, and by adjusting 4d the gaugereading stays the same. This means that the “ P max ” valve is not correctly adjusted. Adjust“P max” valve according to the instructions below, then adjust “4d” until the gauge reads250 bar.
• Checking / Setting the maximum pump pressure “P max”. 1. Start the engine and set the engine speed to 1500 rpm.2. Move the switch Drilling/Tramming to position Drilling.
3. Make sure no functions are activated. (Especially important for L740
and L740
CR)4. Screw pressure relief valve 4d to its end position, so it would not limit the system pressureproduced by pump 1.
5. Screw the “P max” set screw clockwise (if the pressure is too low) or anti-clockwise (if thepressure is too high), while watching gauge 34 until it reads 270 bar.
6. When this is done, re-adjust the screw on 4d until the gauge reads 250 bar, to get back toits normal setting.
Pumps 2, 3 and 4Pumps 2, 3 and 4 are combined to a triple gear pump, mounted on pump 1.The maximum pressure of pump 2 is set by relief valves 4x and 4y in the drill rotation circuit.The pressure of pump 3 can be set on a variable relief valve 13a in the DCT valve block.
f f f
Delta-p
P Max
Pumps & Pilot Pressure
Pilot pressure
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 66/368
ot p essu ePilot pressure is supplied by pump 1 and generated in the main valve block by pressurereducing valve 4b set to 35 bar, and then out to the pilot circuits.
Solenoid valve Y169 control whether the pilot pressure goes to the drilling circuit or to thetramming circuit. Solenoid valve Y169 is activated when the Drilling/Tramming switch S130 is in tramming position and deactivated when the switch is in drilling position.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 67/368
1
L S
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 68/368
2
F e e d / T r a m
Shuttle valve
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 69/368
3
230 bar
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 70/368
4
Cooling fans
Cooling fans
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 71/368
50 510
max
0
Revolution
mA
The rig is equipped with two standard fan drives, one for cooling the compressor/hydraulicoil, and one for cooling the engine water/air inlet. High ambient temperature fan drive forwarmer environment is available as an option.
Conditions for starting the compressor/hydraulic oil temperature cooler fan:
• Compressor temperature sensor B366 => PLC input X16-7OR•
Hydraulic oil temperature sensor B362 => PLC input X16-3Results in:• PLC output X16-9 => Y504 activated
Conditions for starting the engine water/ATAC temperature cooler fan:
• Engine coolant temperature sensor B354 (CAT system)OR• Air inlet temperature(CAT system)Results in:• PLC output X17-4 => Y501 activated
The signal input to solenoids Y504 and Y501 varies between 50mA – 510mA depending onthe cooling demands.
Rig type Full rpm atL7 95 °CL8 120 °C
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 72/368
Tramming
Tramming
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 73/368
Conditions for tramming function:
• Drilling/Tramming switch S130 must be in a tramming position*. => D552-CH2 orCH3/ON
• The hydraulic jack must be fully retracted, sensor B184 activated. => PLC input X10-7/ON (Optional equipment)
• Tramming paddles S174 or/and S175 must be activated. => D553/CH13 or CH14/ONResult in:•
*Y121A/B activated (directly after S130 being put in tramming position)• *Y169 activated (directly after S130 being put in tramming position)• Y206, Y207 activated by respective level.
Tramming direction and speed is controlled via the trammingpaddles ( S174 / S175 see figure). These controls send a signal tothe electrical pilot valves for tramming forward or backward.The pilot pressure changes the directional valves’ positionproportionally and pump 1 supplies the tramming motors’hydraulic circuits with oil.
The output range of the proportional electrical pilot valves fortramming can be adjusted in the menu for“Tramming valve current” under the rig controlicon, thus varying the tramming speed.
The output range lies between330mA – 500mA.
S174 S175
Tramming
Activating the tramming functionWhen the Drilling/Tramming s itch S130 is in an Tramming position (high or lo ) the
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 74/368
When the Drilling/Tramming switch S130 is in any Tramming position (high or low), the
following solenoid valves are activated.
Activation of Y121A:- It allows pump 1 pressure to connect to pressure compensator 4p and 4r in the main
valve block, 4p and 4r also have the functions of dividing the oil flow equally. Thetramming pressure is limited by pressure relief valve 4d set to 230 bar.
Activation of Y121B:- The oil flow from pump 4 goes through pressure relief valve 4c set to 250 bar. The
pressure is then delivered to positioning functions.Activation of Y169:- It allows pilot pressure to come through to the tramming circuit.
The tramming direction and speed are controlled by means of pilot pressure controlling theproportional directional valves. And these directional valves are controlled by solenoid valvesY206A , Y206B , Y207A and Y207B .
The valve block included in the tramming motor 66 contains a shuttle valve 66a , a pilotoperated directional valve 66b and a pressure reducing valve 66c for releasing the trammingbrake when the motor is pressurized. To prevent the motors from increasing speed whentramming down a slope, the over centre valve 66d serves as hydraulic brakes by means ofcreating counter pressure in the motor return line when the pressure in the motor pressure linedrops.
Reverse warningWarning signal/flash H185 is activated when tramming backwards.
Tramming high/low speed The Drilling/Tramming switch S130 position high tramming, activates solenoid valve Y122 .Pilot pressure is then led to directional valve 66f in each traction motor. This connects systempressure to the traction motors displacement device, which reduces the motor displacementand results in increase of traction motor speed.
Rear jack (Option)The rear jack is controlled by on/off switch S209 , which energizes solenoid valve Y410A/B .
Tramming
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 75/368
1
Input / SignalSwitch S130 in a Tramming pos.
Tramming paddles S174 or 175activated
Hydraulic jack retracted, B184 activated(option)
S174 S175
Tramming
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 76/368
2
Input / SignalS130/3 or 5 - D552, CH 2 or 3/ON
S174 or 175 - D553, CH 13 or 14/ON
Output on indicator cardX11-13 Y121A
X17-1 Y121BX11-14 Y122
X11-1 Y169A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 77/368
3
Y121A
Y122
Y121B
Tramming high
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 78/368
4
Y169A
Tramming
4 p o s .
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 79/368
5
Y169A
Y121A
Y121B
Y122
P -
Pump 4
Y473
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 80/368
6
Y419 Y420
Pump 5
Positioning
PositioningThe positioning circuit is mainly supplied with oil from pump 1. However, since the
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 81/368
tramming circuit is also supplied from pump 1, it is necessary to use pump 4 for positioningduring tramming. Since pump 1 is bigger and operates at higher pressure than pump 4, itmeans that positioning is quicker in Drill mode than it is in Tramming mode.
Boom and feed positioningThe positioning cylinders are directly controlled by directional control valve 65 in the cabin.
The boom lift (BL
) and feed dump (FD
) cylinders are equipped with internal over-centervalves, which protect the cylinders from over load and acts as load holding valves. The feedswing ( FS ), feed extension ( FE ) and boom swing ( BS ) cylinders have built in double pilotoperated check valves.The BL cylinder is also equipped with throttle/check valve 64 , on the piston rod side. This isused to adjust the lowering speed of the boom to be equal to the elevating speed.
Positioning during trammingDuring tramming, pump 4 is delivering oil to the positioning circuit, the pressure is limited bythe pressure relief valve 4c set to 250 bar.When the Drilling/Tramming switch S130 is in tramming position, solenoid valve Y121B isactivated. This pressurizes the pump 4 circuit.
Track oscillationThe track oscillation solenoid valves Y419 and Y420 are controlled by switch S176 and S177 respectively.The oscillation cylinders are hydraulically linked by a two positioned solenoid valve, Y473 ,controlled by switch S445 .
- ON, FloatingWhen solenoids valve Y473 is activated with switch S445 inposition (a), the valve is open allowing system pressure to openthe over centre valves in the Track Oscillation valve block 68 .Both cylinders are inter-connected to enable oil to flow betweenthe two cylinders. This valve position is used during tramming sothat ground unevenness can be compensated between the
a
b c
d
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 82/368
Positioning
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 83/368
1
Input / SignalTrack oscillation left S176, right S177
Track oscillation float/lock switch S445
Hydraulic jack S209
Positioning
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 84/368
2
Input / SignalS176/A1 or A3 – D552, CH 5 or 6/ON
S177/A1 or A3 – D552, CH 7 or 8/ON
S445/A3 – D554, CH 2/ON (floating)
S209/A1 or A2 – D552, CH11 or 12/ON
Output on indicator cardX13-9, X13-10 Y419A/B
X15-5, X15-6 Y420A/B
X15-7 Y473
X12-6, X12-7 Y410A/B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 85/368
3
L
S
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 86/368
4
Y121A
2 3 0
b a r
F e e
d / T
r a m
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 87/368
5
Y419 Y420
Y473
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 88/368
6
Y419 Y420
P - 4 p o s .
Track oscillation /positioning are supplied
by pump 4 when tramming
P - 4 p o s .
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 89/368
7
Y121B
Pump 4
P
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 90/368
Air System & Compressor
Air System & Compressor
Air System
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 91/368
Air SystemCompressed air is used for the following rig functions:• Flushing air
Full flushing and reduced flushing air. Transportation of drilled cuttings from the holeto the surface. The reduced flushing is mainly used during collaring through fissuredground, to prevent the air from destroying the hole walls.
• ECL, rock drill lubrication systemDistribution of lubrication oil inside the rock drill.
• HECL, DTH Hammer lubrication system Distribution of lubrication oil inside the DTH Hammer.
• HECL, COPROD head and sections lubrication systemDistribution of lubrication oil inside the COPROD head and sections.
• ECG, thread greasing systems (option)Distribution of lubrication oil onto the drill rod threads.
• Spray greasing system (option)
Distribution of lubrication oil into the flushing air.• DCT, dust collector
Cleaning of the DCT filters.• Extra air-outlet
Provides air for running tools or grinders.• Water-mist system (option)
Pressurization of the air/water tank.
Flushing air – L7 40 , L7 40CRConditions for the flushing air function:
• Switch S130 in Drilling position => input D552-CH1/ON• Sensor B118 activated, RHS arm in carousel => PLC input
X10-5/ON• Switch S100 in position reduced (b) or full (a) => input
D551-CH1/ON or OFF• Switch S446A in Impact position => input D550-CH9/ON
(To start only flushing, press the impact switch S446A for shorterthan 0.5 seconds. To start low impact, press the switch for longerthan 0 5 seconds Pressing the switch again for shorter than 0 5
S100a
b
Air System & Compressor
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 92/368
Flushing air – L8 30 Conditions for the flushing air function:
• Switch S130 in Drilling position => input D552-CH1/ON• Sensor B118 activated, RHS arm in carousel => PLC input X10-5/ON• Switch S446A/B in Impact position => input D550-CH9/ON or CH10/ON
There are two air flushing modes, reduced and full air flushing, activated by solenoid valvesY116 and Y115. When full air flushing is activated by S446B , both the valves are open; andwhen reduced air flushing is activated by S446A , only Y116 is open.
Air System & Compressor
ECL, rock drill lubrication systemSee section “ECL, rock drill lubrication system” under chapter “Drilling”.
HECL, DTH hammer lubrication system
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 93/368
HECL, DTH hammer lubrication systemSee chapter “HECL, DTH hammer lubrication system” under “Drilling”.
HECL, COPROD head and sections lubrication systemSee section “HECL, COPROD head and sections lubrication systems” under chapter“Drilling”.
ECG, Thread lubrication systems (Option)See chapter “ECG, thread lubrication with oil (Option)”.
Spray greasing system (option)The lubrication is injected into the flushing air and dissipates through the treads of the drillrods to keep them lubricated.See chapter “Spray greasing system (Option)”.
DCT, dust collectorSee chapter “Dust collector, DCT”.
Extra air-outletThe rig is equipped with two air outlets where a grinder or tool can be connected. The airpressure is limited to 7 bar by a pressure reducing valve.
Water-mist system (option)See chapter “Water mist systems (Option)”.
Compressor
General – L7 40 , L7 40CRThe on board compressor is a single stage, oil-injected screw compressor. The normalworking pressure has been set to 12 bar, whereas the maximum pressure is 14 bar. Themaximum free air delivery (FAD) is 252.7 l/sec at 12 bar working pressure with 20°Cambient temperature.
Air System & Compressor
Compressor element – L8 30 The compressor element contains two rotors, one female and one male rotor, mounted onroller as well as ball bearings. The female rotor is driven by the diesel engine, and powers themale rotor. The rotors are lubricated by oil, injected and mixed with the air. This also
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 94/368
y , jincreases the efficiency as the oil seals between the rotor-tips and housing. The compressorelements are of Atlas Copco type OIS N-02 and OIS J-33. The gear ratio is 2.195.
Air flowIntake air is drawn in through the air filter and the inlet valve to the compressor element. Theair is mixed with injected oil and after compression is passed through the check valve into the
air receiver. The check valve prevents back-flow of compressed air when the compressor isstopped. In the air receiver, most of the oil is removed from the air/oil mixture by the oilseparator. The flow of compressed air then passes through the minimum pressure valve outinto the drill rigs air system. The minimum pressure valve prevents the pressure in the airreceiver to drop below the minimum working pressure of the compressor before the air isreleased, in order to ensure proper function of the oil system.
Air Atmospheric Pressure
Air Regulating Pressure
Air Working Pressure
Air/Oil Mixture
Oil
Air System & Compressor
Cooling and oil systemOil is used for lubrication, sealing, cooling and is boosted by air pressure, there is no oilpump. The lower part of the air receiver serves as oil tank. Air pressure forces the oil from theair receiver through the oil cooler, oil filter and the oil stop valve to the different injection
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 95/368
g p jpoints of the compressor element. The air/oil mixture then leaves the compressor element andre-enters the air receiver, where the oil is separated from the air by centrifugal or cycloneforces and the oil separator element. Oil that is collected in the bottom of the oil separator isreturned to the oil system by way of the scavenge line and flow restrictor. The oil stop valveprevents the compressor element from flooding with oil when the unit is stopped.
Note: A thermostatic valve bypasses the oil cooler when the oil is below 40 °C for L740
,L740CR, and 80 °C for L8 30.
Regulating system – L7 40 , L7 40CRThe compressor control system contains a regulating valve. This valve serves to adapt thevolume of air supplied by the compressor to the air consumption, while simultaneouslymaintaining the working pressure within the limits.The control system also includes a loading solenoid valve Y210 which is activated by switchS180 on the right hand control panel.
Regulating system – L8 30 The compressor control system contains two regulating valves. These valves serve to adaptthe volume of air supplied by the compressor to the air consumption, while simultaneouslymaintaining the working pressure within the limits.The control system also includes a load solenoid Y210A and a high/low pressure solenoid
valve Y210B . Y210A is activated by switch S180 on the right hand control panel. Onepressure switch B336 prevents the engine to start with the compressor loaded, which impliesthere should be less than 1 bar in the air receiver before starting the engine. The secondpressure switch B337 prevents the compressor to load below 5 bar. Solenoid valve Y210B isactivated when high impact switch S446B is activated.
Instrumentation & fault indication – L7 40 , L7 40CRThe compressor air pressure delivered from the compressor can be read-off pressure gauge.The compressor has also a temperature indicator-switch, B366 , which automatically generatea warning on the display if the compressor temperature has reached +117°C, and cuts thediesel engine if the compressor temperature has reached +120°C.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 96/368
Compressor
Input / Signal
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 97/368
1
Input / SignalSwitch S130 in any position after
engine start
Compressor load switch S180
activatedFor L6, L8 only – Minimum loading
pressure switch B337 activated
Compressor temperature normal –
B366A/B below limits
Compressor
Input / Signal
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 98/368
2
Input / SignalS180/A3 - D552,CH 9/ON
For L8 30 only, B337 - X13-3/ON
Output on indicator cardX18-8 Y210A (for all)
X12-1 Y210B (for L8 30 )
Y210Regulating valve
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 99/368
3
Inlet valve safety valveB366
B365
Oil filter & thermostat
Min pressurevalve
Regulating valvesY210A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 100/368
4
Inlet valveB366B
B365
Oil filter & thermostat Min pressurevalve
B366A
safety valve
Y210B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 101/368
Y210Regulating valve
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 102/368
6
Oil cooler
Main air flow
Inlet valve safety valveB366
B365
Oil filter & thermostat
Regulating valvesY210A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 103/368
7
Inlet valveB366B
B365
Oil filter & thermostat
B366A
safety valve
Y210B
Y210A
L830
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 104/368
8
Compressor loaded& High impact
Y210B
Regulating valvesY210A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 105/368
9
Inlet valveB366B
B365
Oil filter & thermostat
B366A
safety valve
Y210B
Oil cooler
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 106/368
Oil pre-heating
Oil pre-heating
Oil pre-heating – L7 40 , L7 40CRPump 2 is used for pre-heating the hydraulic oiland the rock-drill impact components. Normal
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 107/368
p poperating temperature of the hydraulic oil is40°C. Before operating the drill rig the oilshould be pre-heated to minimum operatingtemperature, 20°C.
When switch S130 is in the pre-heating position,solenoid valve Y121A and Y121B are activated.Solenoid valves Y120A , Y120B and Y120C arealso activated in order to perform pre-heating.
Pre-heating the hydraulic oil:When activating Y120A , pressure is generatedin the pressure chamber of 4x . This pressure islimited by 4y to 170 bar. The flow of pump 2goes through the shunt valve 4x with a pressureof 170 bar + spring pressure (11 bar).
Pre-heating the rock-drill components:Y120B blocks the impact return line from therock-drill, Y120C opens and oil flow from
pump 2 is fed through the hammer return lineand back to the tank through the hammerpressure line.
Note : It’s possible to tram the rig at the sametime warming up the hydraulic oil, solenoidvalve Y169 can also be activated when S130 inpre-heating position.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 108/368
Oil pre-heating
Input / SignalSwitch S130 in Oil preheating pos
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 109/368
1
Switch S130 in Oil preheating pos.
Oil pre-heating
Input / SignalS130/7 - D552,CH 4/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 110/368
2
S130/7 D552,CH 4/ON
Output on indicator cardX11-13 Y121A
X17-1 Y121B
X11-12 Y120A, Y120B, Y120C
(Y120B/C only ROC L7)
Y120B/C only
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 111/368
3
Y121A
Y121B
Y120A,B,C
Y120B/C onlyfor L7TH+CR
Page 35
Page 34
Oil pre-heating
Oil pre-heating
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 112/368
4
Y121A
Y121B
Y120A
Y120B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 113/368
5
Y120C
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 114/368
Drilling functions
Drilling functions
Activation of drilling functions – L7 40 , L7 40CRWhen S130 is in drilling position, Y121A and Y121B are not activated, Y169 is deactivatedto let through pilot pressure to the drilling circuits.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 115/368
De-activation of Y121A:- It allows pump 1 pressure to connect to LS/pump pressure line directly. If impact is
activated, the pump pressure will be according to the preset values of thehammer/pump pressure pressure relief valves ( 47e and 47f ) in the logic block. If
impact is not activated, the working pressure is limited by pressure relief valve 4d .De-activation of Y121B:- The pump 4 pressure supplied to positioning functions during tramming, is now used
for rotation function together with pump 2. This is simply to assist pump 2 for a betterrotation output.
De-activation of Y169:- Pilot pressure is now led to the drill lever through logic valve and to the DCT circuit,
PLC output X11-1/OFF.
The Drilling functions such as Drill feed, Rapid feed, Rotation and Threading functions are allcontrolled by one drill lever.
Activation of drilling functions – L8 30 When S130 is in drilling position, Y121A and Y121B are not activated, Y169 is deactivated
to let through pilot pressure to the drilling circuits.
De-activation of Y121A:- It allows pump 1 pressure to connect to LS line directly. The working pressure is
limited by pressure relief valve 4d .De-activation of Y121B:
- The pump 4 pressure supplied to positioning functions during tramming, is now usedfor rotation function together with pump 2. This is simply to assist pump 2 for a betterrotation output.
De-activation of Y169:- Pilot pressure is now led to the drill lever through logic valve and to the DCT circuit,
Drilling functions
Drill feedThe drill feed circuit includes functions for feeding down- and upwards and controlling thefeed pressure during collaring and drilling. The hydraulic power is supplied from pump 1.The Anti-Jamming circuit is described separately, see chapter “Protective functions”.
• Drill feed direction, Up-/Downwards
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 116/368
pThe drill feed/rotation lever 45 controls the directional valve 4f via the logic block. SolenoidsY179A and Y179B are to control the magnetic locks for drill lever feed and rotationfunctions.
Led greenH452
Rapid/ drill feedS452
Impact lowS446A
Impact highS446B
Magnet offS453
Led yellowH446
L7 40 Drill mode:E: neutralB: rotation anti-clockwiseB+A: rotation anti-clockwise and feedforward ( magnet function )
B+C: rotation anti-clockwise ( magnetfunction ) and feed backward.D: Feed forward ( magnet function )F: Feed backwardH i l k i
Rapid feed / threading mode:E: neutralB: ThreadingB+A: rotation anti-clockwise and rapid feedforward
B+C : rotation anti-clockwise and rapid feedbackwardD: Rapid feed forwardF: Rapid feed backwardH U h di
75
6
8
B
C I
H
G A D
F
E Drill rotation
Magneticholding
Drill feed
Magnetic holding
Drilling functions
L7 40CR, L8 30
Drilling mode:E: neutralB: rotation clockwiseB+A: rotation clockwise and feed forward(magnet function )B+C: rotation clockwise ( magnet function ) andfeed backward
Rapid feed / threading mode:E: neutralB: ThreadingB+A: rotation clockwise and rapid feedforwardB+C : rotation clockwise and rapid feedbackward
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 117/368
feed backward.D: Feed forward ( magnet function )F: Feed backwardH: rotation anti-clockwiseH+G: rotation anti-clockwise and feed forwardH+I: rotation anti-clockwise and feed backward
Diode H452 is lit in this mode.
backwardD: Rapid feed forwardF: Rapid feed backwardH: UnthreadingH+G : rotation anti-clockwise and feedforwardH+I: rotation anti-clockwise and feedbackward
There is no diode indication in this mode.
Magnetic holding on rotation during drilling or/and feeding forwards can only be achievedwhen the control lever is being pulled to the end position, and when S452 is not activated(Led H452 = ON). Pulling the lever only half way and then release would result in leverspringed back to the neutral position, which also marks the end of the movement.
Conditions for drill feed with magnetic holding:
• Switch S130 in drilling position => D552-CH1/ON• Switch S452 in feed/rotation mode, not activated => D550-CH11/OFFResult in:•
Relay K178 /OFF• Y179A/B , H452 activated
To unlock the magnetic lock and get the lever back to the neutral sector, activate switch S453or shift the lever to Rapid feed position with switch S452.
Conditions for deactivation of magnetic holding:
• Switch S453 activated => D550-CH12/ON OR • Switch S452 in rapid feed/threading mode => D550-CH11/ON R l i
Drilling functions
The feed circuit is supplied with oil from pump 1. In drill mode the electrical pilot valvesY178A-F are not activated. When feed is activated with the drill lever the pilot pressure isdirected first via either directional valves Y178A or B depending on the choice of feed
direction, then via directional valve Y109 which changes the feed direction in case of anti- jamming and out to the directional valve in the drill feed block. Anti-jamming is describedlater.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 118/368
• Main valve block 4The pilot operated directional valve 4f in the main valve block, directs the hydraulic power tothe feed cylinder. The pilot operated pressure compensator 4e regulates the feed workingpressure.
• Feed pressuresThe pressure for forward feeding can be read on pressure gauge 33 .The feed pressure is generated from the system (Feed/Tram) pressure by pump 1, and it isregulated by pressure relief valve 4d . When feeding forwards, the pressure relief valves 47a or 47b limits the maximum pressure to the feed cylinder. If these pressure relief valves wouldfor some reasons fail to work, then the check valve 4n would limit the maximum pressure.
Drilling functions
- Low feed pressure (collaring)When the impact control switch S446A is activated (impact pressure low), solenoidvalve Y101C is deactivated, which allows the low feed pressure relief valve 47a to
control pressure compensator 4e in the main valve block.- High feed pressure (drilling)
When the Impact control switch S446B is activated (impact pressure high), solenoidvalve Y101C is activated which allows the high feed pressure valve 47b to control
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 119/368
valve Y101C is activated, which allows the high feed pressure valve 47b to controlpressure compensator 4e in the main valve block.
- Feeding backwardsWhen feeding backwards, solenoid valve Y101C is deactivated, which allows the lowfeed pressure relief valve 47a to control pressure compensator 4e in the main valveblock. But if feeding backwards is activated in connection with anti-jamming,solenoid valve Y101C remains activated and the high feed pressure relief valve 47b will control pressure compensator 4e in the main valve block.
• Feed cylinder valve block 5The feed valve block 5 contains one over-centre valve 5b . The over-
centre valve 5b works as load holding valve when the cylinder ispressurized for feeding forwards.
• Feeding speedThe drill feed speed is set to correspond to a drill feed speed of 15m/min upwards and 8 m/min downwards.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 120/368
Drill feed
Input / SignalSwitch S130 in Drilling pos.
Drill feed
Magnetic holding
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 121/368
1
Drill lever in a feed position
Feed forward – D
Feed backward – F
OutputFeed forward magnetic
holding
– D550, CH8/ON Y179A
Drill lever in drill mode – D550, CH15/ON H452
(No magnetic holding in pos. F)
75
6
8
B
C I
H
GA
D
F
EDrill rotation
Magneticholding
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 122/368
2
Y169
Feed p.
F e e d / T r a m
F e e d p
.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 123/368
3
O
Pilot lever
F e e d p
.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 124/368
4
Y101C
Pilot lever
O
Pilot lever
Drilling functions
Drill rotation
• Drill rotation, clockwise/anticlockwise
Conditions for drill rotation with magnetic holding:
• Switch S130 in drilling position => D552-CH1/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 125/368
g p• Switch S452 in feed/rotation mode, not activated => D550-CH11/OFF Result in: • Relay K178 /OFF•
Y179A/B activated, H452 activated
Note : When Y179A/B is activated the magnetic holding is obtained when the drill lever ismoved to the sectors for drill rotation or/and drill feed.
Conditions for switching off rotation and magnetic holding:
• Switch S453 activated => D550-CH12/ON OR • Switch S452 in rapid feed/threading mode => D550-CH11/ON Result in: • Y179A/B deactivated
When switch S453 is pressed once on the drill lever the magnets will be temporarilydeactivated and the drill lever returns to neutral position which results in feed and rotation
being switched off, with impact and air flushing remains on.Magnetic holding can also be switched off once S452 is activated, thus shifting to rapidfeed/threading mode where magnetic holding is not supported. The actual impact and airflushing at this point will also be switched off.
Note: Magnetic holding will be automatically reactivated after a delay of 0.2 seconds ifswitch S453 is deactivated. This means that the next time the drill lever is moved to one ofthese sectors (sector for drill feed or drill rotation), magnetic holding will be activated again.
When rotation is activated (with the drill lever) the pilot pressure is directed, via electricalpilot valve Y178C or D depending on the choice of rotation direction, then to the directional
Drilling functions
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 126/368
• Rotation speed- L7 40 Anti-clockwise rotation (drilling); L7 40CR & L8 30 Clockwise rotation (drilling)When the drill lever is in “Drill-rotation” position, the setting of the flow regulatorcontrols how much the directional valve 4w will open. The flow to the rock drill rotationmotor is proportional to the opening of the directional valve 4w .- L7 40 Clockwise rotation; L7 40CR & L8 30 Anti-clockwise rotationThe drill lever controls the rotation speed. The main directional valve 4w opens incorrespondence to the lever angel. The flow regulator is not connected.
The adjustment knob for flow regulator can be seen in chapter “Adjustment/calibration”.
• Rotation pressures
The rotation pressure is generated by pump 2 with the assistance of pump 4 when drilling.Depending on the direction of rotation, the pressure relief valve 4u or 4t is activated to limitthe maximum pressure for clockwise and anti-clockwise rotation respectively.L7 40 : The maximum pressure for rotation anti-clockwise is limited to 125 bar (valve 4t ), and
Rotation
Input / SignalSwitch S130 in Drilling pos.
Drill lever in a feed position 6
GA
Drill feed
Magnetic holding
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 127/368
1
Drill lever in a feed position
Rotation drilling – B
Rotation unthreading – H
OutputDrill rotation magnetic holding
– D550, CH7/ON Y179B
Indication of drill lever in drillmode – D550, CH15/ON H452
(No magnetic holding in pos. H)
75
6
8
B
C I
H
GA
D
F
EDrill rotation
Magneticholding
Pil t
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 128/368
2
Pilot pressure
D
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 129/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 130/368
Drilling functions
Rapid feed
• Rapid feed direction, Up-/Downwards
When the lever is in the rapid feed/threading mode, magnetic holding is not available.
Conditions for rapid feed:
• Switch S130 in drilling position => D552 CH1/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 131/368
Switch S130 in drilling position => D552-CH1/ON• Switch S452 in rapid feed/threading mode, activated => D550-CH11/ONResult in:•
RelayK178
/ON→
Y178
activated• Y179A/B deactivated
In rapid feed mode the electrical pilotvalves Y178A-F are activated (seefigure right). When rapid feed isactivated with the drill lever the pilotpressure is directed via solenoid
Y178A or B depending on the choiceof direction, to the directional valve inthe main valve block.
• Main valve block 4The proportional directional valve 4j directs the hydraulic power to the feedcylinder. The pilot operated pressurecompensator 4i regulates the rapid feedworking pressure.
• Rapid feed pressuresThe feed pressure for rapid feed isgenerated from pump 1, and it is regulated by pressure relief valve 4d . Depending on thedirection of rapid feed, the pressure relief valves 4l or 4k limits the maximum pressure to the
feed cylinder, forward and reverse respectively. The maximum pressure for feed forward islimited to 220 bar, and the maximum pressure of feed backward is limited to 170 bar. If thesepressure relief valves would for some reasons fail to work, then the check valves 4n and 4m
ld l h
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 132/368
Drilling functions
• Rapid feed stops – L8 30
M 4 M 3 M 2 M 1
Stop forward (M1) – Rapid feed stop forward above the breakout table, so the rock drill canbe threaded into the tube caught in the lower breakout jaw
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 133/368
be threaded into the tube caught in the lower breakout jaw.Stop lower uncoupling (M2) – Rapid feed stop backward, when the joint between two tubesis between the breakout jaws in order to break the tube threads.Stop upper uncoupling (M3) – Rapid feed stop backward, when the tube is in correctposition to be inserted into the magazine.Stop backward (M4) – Rapid feed stop backward, at a position above the RHS magazine,but before mechanical stop. This stop is used prior to adding a new tube into the drill centre.
The rapid feed stops are software stopsthat are controlled by the PLC. All thestop distances can be set in the display.
Figure: L7 40
& L8 30
rapid feed stop settings
Drilling functions
• Rapid feed stops – L7 40CR
M 4 M 3 M 2 M 1 M 0
Impact stop (M0) – Feed stop forward between M1 and the mechanical stop forward. Noimpact is allowed if the rock drill is too near the mechanical stop
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 134/368
impact is allowed if the rock drill is too near the mechanical stop.Stop forward (M1) – Rapid feed stop forward just above the breakout table, so the rock drillcan be threaded into the tube caught in the lower breakout jaw.Stop lower uncoupling (M2) – Rapid feed stop backward, when the joint between two tubesis between the breakout jaws in order to break the tube threads.Stop upper uncoupling (M3) – Rapid feed stop backward, when the tube is in correctposition to be inserted into the magazine.Stop backward (M4) – Rapid feed stop backward, at a position above the RHS magazine,but before mechanical stop. This stop is used prior to adding a new tube into the drill centre.
The rapid feed stops are software stops
that are controlled by the PLC. All thestop distances can be set in the display.
Rapid feed stop activationWhen the measured distance happens to equal to the distance set inthe display, solenoid valves Y149 (backward) or Y150 (forward)
in the logic valve block is activated by PLC output X16-10 orX17-2.Solenoid valve Y149 gets activated by M2, M3 and M4, where assolenoid valve Y150 only gets activated by M1 If any of the two
S113
Figure: L7 40CR rapid feed stop settings
Drilling functions
Calibrating B172 In order for these build-in software stops to work, calibration sensor B104 is used to calibratethe depth encoder B172 . The depth encoder B172 is an optical encoder which throughsending out pulses defines the position of the cradle on the beam.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 135/368
Note: The menu illustration shown does notcorrespond to the actual position.
The distance to be entered in the display is the cradle travel distance between the rear endmechanical stop and when the indicator plate actuates sensor B104 . This value can be put inmanually or automatically.
Manual inputOperator needs to use a ruler to manually measure the distance between the front of the rockdrill cradle indicator plate and the calibration sensor B104 , when the rock drill is in its rearend stop.
Automatic inputThe cradle needs to be moved back to the upper most position at the mechanical stop. To
carry out this movement, the drill lever needs to work in drill mode. Once the cradle hasreached the top end, reset the position of the cradle. Then mark the check-box for “Auto setsensor position”, now move the drill lever forward slowly so the cradle can pass through thecalibration sensor B104 at a maximum speed of 4m/min. Once B104 is activated, a value ispresented on the display.
Note: It’s recommended that both manual and automatic input is done to ensure a betterprecision. This distance is a factory setting, it is not necessary to change the distance unlesssensor B104 has been moved, or if the rock drill’s rear-end mechanical stop has beenchanged, i.e. if the feed ropes have been replaced or tensioned.
Drilling functions
Threading
• Threading and un-threading
When the lever is in the rapid feed/threading mode, magnetic holding is not available.
Conditions for threading/unthreading:
• Switch S130 in drilling position => D552-CH1/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 136/368
• Switch S452 in rapid feed/threading mode, activated => D550-CH11/ONResult in:• Relay K178 /ON → Y178 activated• Y179A/B deactivated
In threading mode the electrical pilot valves Y178A -F are activated just as in rapid feedmode. The threading function is a combined activation of both drill feed and rock-drillrotation by one lever stoke. When threading is activated with the drill lever the pilot pressureis directed via the activated solenoid Y178C or D depending on the choice of threadingdirection, and then to the directional valve in the drill feed and rotation block respectively.
• Rod coupling feed pressuresThreading and unthreading functions need two different feed pressures since unthreadingrequires higher pressure than threading. Pressure relief valves 47d and 47c control themaximum rod coupling feed pressure for feed forward ( L7 40 : threading – anti-clockwise;L7 40CR & L8 30 : threading – clockwise) and backward ( L7 40: unthreading – clockwise;L7 40CR & L8 30 : unthreading – anti-clockwise) respectively. Depending on the choice ofthreading, pressure relief valves 47c and 47d will then in turn control pressure compensator4e in the main valve block.
By pulling the lever to the left (threading), logic valve G is activated, which connects the feedpressure to the pressure relief valve for thread feed forward 47d . And by pulling the lever tothe right (unthreading), logic valve H is activated, which connects the feed pressure to thepressure relief valve for thread feed backward 47c .
•
Drill feed and rotation speed when threading Rotation:When rotation is activated by the threading lever, the flow regulator which controls therotation pilot pressure signal is excluded from the circuit This means that the rotation speed is
Rapid feed
Input / SignalSwitch S130 in Drilling pos.
Drill lever in rapid feed mode 6
GA
Drill feed
Magnetic holding
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 137/368
1
S452 activated – D550, CH/11/ON
Drill lever in a rapid feed position
Rapid feed forward – D
Rapid feed backward – F
Output on indicator cardRelay K178 activated
– X12-2 K178 Y178A-E
75
8
B
C I
H
D
F
EDrill rotation
Magneticholding
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 138/368
2
K178
Y178A-F
Rapid feed +coupling
Pilot lever
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 139/368
3
Y178D
Y178C
Y178B
Y178A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 140/368
4
Y169
Y178E,F
F e e d / T r a m
R
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 141/368
5
Y149
Y150
Note: Only one of them (Y149, Y150) is activated at a time.
Rapid feed stop
Pilot lever
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 142/368
6
Y149 Y150
Rod coupling
Input / SignalSwitch S130 in Drilling pos.
Drill lever in rapid feed mode 6
GA
D
Drill feed
Magnetic holding
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 143/368
7
S452 activated – D550, CH/11/ON
Drill lever in a rod coupling position
Threading – B
Unthreading – H
Output on indicator cardRelay K178 activated
– X12-2 K178 Y178A-E
75
8
B
C I
H
D
F
EDrill rotation
Magneticholding
Pilot lever F e e d p
.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 144/368
8
RotationFeed
FEED
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 145/368
9
Pump 2
ROTATION
Y169
Y178E,F
Pilot lever F e e d p
.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 146/368
10
P
Drilling functions
Impact with air flushing – L7 40 , L7 40CRConditions for the impact function:
•
Switch S130 in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON• Flushing air switch S100 in reduced or full position => D551-CH1/ON or OFF• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Impact switch S446A or S446B must be activated => D550-CH9/10/ON• The rock drill damper pressure must be between 45 and 120 bar. (DPC-I)
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 147/368
The impact circuit includes function for activating the rock drill impact mechanism andcontrolling the pressure for collaring and drilling (low and high pressure). The circuit alsoactivates the Impact hour counter (a function of the HEC software in the display).
The hydraulic power is supplied from pump 1.To protect the rock drill and drill steel, the DPC-I system can shut off or lower the impactpressure if certain conditions are met. The DPC-I system is described separately, refer tochapter “Damper & DPC-I system”.
Activation of ImpactPressing the impact control switch S446A/B for longer than 0.5 seconds activates lowrespective high impact under the condition that high impact is achieved after first using lowimpact. Otherwise if starting directly on high impact, the button for high impact activationS446B must be held in at all time. Logic valves I and J in the DPC-I system sense the rockdrill damper pressure. If the damper pressure is lower than the preset value of logic-I orhigher than the preset value of logic-J, the valves will prevent activation of impact.When impact is activated, pump 1 system pressure is also led to logic valve B , which allowsany of the two impact pressure relief valves 47e and 47f to take control over the pump 1pressure. In ROC L7 40CR , there is also a logic valve O that will stop/prevent impact whenfeed pressure is below its preset value.
S446A/B controls the activation of solenoid valves Y115 , Y116 in the air system, but it isS100 that controls the combination of Y115 and Y116. It’s recommended to keep S100
activated to allow full flushing air pressure as soon as S446 is activated. S100 should beswitched off (changing to reduced flushing air) only when drilling through a weaker complexof the rock layer. S446A/B also control three solenoids valves in the hydraulic system,Y101A f i i i Y101B f i i l i Y101C f i hi
Drilling functions
Air flushing:Solenoid valve Y116 (or Y116+Y115) is activated to engage reduced (or full) airpressure depending on the status of Y100, and the air pressure is directed to theregulating valve for air pressure regulation.
Drill feed:The drill feed low pressure solenoid valve Y101C is not activated in order to engagelow feed pressure.
- High impact pressureWhen the high impact control switch S446B is activated, the following will take place
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 148/368
When the high impact control switch S446B is activated, the following will take placein respect to all the pressures needed for the impact function. Led H446 will be
activated to give stable signal. Impact/pump1 pressure:Logic valve B is activated since solenoid valve Y101A is ON , logic valve E isactivated since solenoid valve Y101B is OFF , logic valve D is activated by rotationpressure, and damper pressure now meets logic valve A . If the damper pressure is highenough to overcome the preset value of logic-A, pump 1 Load Sensing line isconnected to the high impact relief valve 47f . Otherwise logic-A is deactivated, thusconnecting the pump 1 Load Sensing line to the low impact relief valve 47e .
Air flushing:Solenoid valve Y116 (or Y116+Y115) is activated to engage reduced (or full) airpressure depending on the status of Y100, and the air pressure is directed to theregulating valve for air pressure regulation.
Drill feed:The drill feed low pressure solenoid valve Y101C is now activated in order to engagehigh feed pressure, under the condition that the RPC-F valve logic-B is not activated.
Refer to RPC-F under “Protective functions”.Deactivation of impactImpact can be deactivated by pressing S446A/B for shorter than 0.5 seconds. If the lever issituated in magnetic holding position, impact will be switched off with the lever returning tothe neutral position, thus also switching off feed , rotation and air flushing .
Impact hour counter
The impact hour counter is a build-in function of the HEC system. As long as either of theimpact switches S446A or S446B is activated, the counter in the software keeps counting.
Drilling functions
Impact – L8 30 Conditions for the impact function:
•
Switch S130 in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Impact switch S446A or S446B must be activated => D550-CH9/10/ON
The impact circuit includes function for activating the DTH hammer impact mechanism andt lli th f ll i d d illi (l d hi h ) Th i it l
L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 149/368
controlling the pressure for collaring and drilling (low and high pressure). The circuit alsoactivates the Impact hour counter (a function of the HEC software in the display).
Activation of ImpactPressing the impact control switch S446A/B for longer than 0.5 seconds activates lowrespective high impact.
The impact control switch S446A/B , positions low and high, control three solenoid valves inthe air system, Y116 , low impact, Y115 , high impact and Y210B , high/low air pressure
regulation. They also control one solenoid valve in the hydraulic system, Y101C , switchingbetween high/low feed pressure.
Impact feed and air pressures- Low impact pressure
When the low impact control switch S446A is activated, the following will take placein respect to all the pressures needed for the impact function. Led H446 will beactivated to give blinking signals.
Air pressure for impact and flushing:When the impact control switch S446A is activated, solenoid valve Y116 is activatedto give reduced flushing air, and the air pressure is being controlled by the regulatingvalve set to 18 bar via the un-activated compressor high pressure solenoid valveY210B .
Drill feed pressure:The drill feed low pressure solenoid valve Y101C is not activated in order to engagelow feed pressure.
- High impact pressure When the high impact control switch S446B is activated the following will take place
Drilling functions
Deactivation of impactImpact can be deactivated by pressing S446A/B for shorter than 0.5 seconds. If the lever issituated in magnetic holding position, impact will be switched off with the lever returning tothe neutral position, thus also switching off feed , rotation and air flushing .
Impact hour counterThe impact hour counter is a build-in function of the HEC system. As long as either of theimpact switches S446A or S446B is activated, the counter in the software keeps counting.
L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 150/368
Impacthour countsince last
reset.
Accumulatedimpact hours
(can not be reset)
Drilling functions
Impact stroke lengthThe stroke length of the COP 4050, COP 4050CR impactpiston is electrically controlled through switch S400.
When S400 is in position (a) => D553-CH7/ON:- Solenoid valve Y175 is not activated, only short
stroke length is available.
When S400 is in position (b) => D553-CH7/OFF:- If low impact S446A is activated, Y175 is not a
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 151/368
activated, only short stroke length is available
- If high impact S446B is activated, Y175 is activated,only long stroke length is available.
When solenoid valve Y175 (PLC output X17-15) is activated, it is not opento allow pump 1 impact pressure to affect the stroke position valve in the rock-drill, the rock-drill will use long stroke length. When Y175 is deactivated, it is open to the pump 1 impactpressure line and the rock-drill will use the short stroke length.
Which position to use has to be decided from the rock condition. Drilling in softer formations,each stroke can contain more energy than can be absorbed by the rock. In such cases it can bebetter to use only the short stroke length.
S400
b
Figure: example, L7 40 left panel
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 152/368
Impact / Flushing air
Input / SignalSwitch S130 in Drilling pos.
Gripper sensor B118 in carousel pos.
Impact switch S446A or B activated
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 153/368
1
p
Compressor load switch S180 activated(mandatory for L6, L8)
12
3
56
4
Drill feed
75
6
8
B
C I
H
GAD
F
EDrill rotationMagneticholding
Magnetic holding
Impact / Flushing air
Input / SignalS130/1 - D552,CH 1/ON
S180/A3 - D552,CH 9/ON
S100/A3 D551 CH1/ON or OFF
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 154/368
2
S100/A3 - D551, CH1/ON or OFF
S446A or B - D550, CH9 or 10/ON
B118 - X10-5/ON
Output on indicator card
Drilling - D550, CH16/ON H446X17-13 Y115
X17-14 Y116
X11-9 Y101A
X13-12 Y101B
X11-15 Y101C
X18-8 Y210A
X12-1 Y210 B
Y116
Page 38 Reduced flushing air, also impact low L8 30
L740 , L7 40CR, L8 30
L740 , L7 40 CR, L8 30
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 155/368
3
Y101A
Y101B
Page 40 Compressor loading, also impact low L830
L740 , L7 40CR
Impact low
Y210A
Page 34
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 156/368
4
Y116Y115
M
a i n a
i r f l o w
B142L7TH/CR only
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 157/368
5
M a
i n a
i r f l o
w
7 bar
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 158/368
6
Pilot lever
Y175
P
F e e
d p .
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 159/368
7
Q
I
O
JY101AY101B
D
B
C
Pump p.
Impact low on ROC L7 40
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 160/368
8
Y116
Page 38 Full flushing air, also impact high L8 30
L740 , L7 40CR, L8 30
L740 , L7 40CR, L8 30
Y115
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 161/368
9
Y101A
Page 34 Max feed pressure, impact high
L740 , L7 40CR
Impact high
Y210A
Page 34
Y101C
Y210B
L830
Y210A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 162/368
10
Impact high
i r m
i x t u r e
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 163/368
11
Y106Tank
O i l / a
Y116Y115
M
a i n a
i r f l o w
B142L7TH/CR only
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 164/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 165/368
13
Y101C
Pilot lever
Y175
Pump p.
F e e
d p .
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 166/368
14
Q
I
O
JY101AY101B
D
B
C
high
Y101C
Impact high on ROC L7 40
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 167/368
15
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 168/368
Drilling functions
ECL, rock drill lubrication system
FunctionECL pump Y106 starts to pump as soon as Impact is turned ON. The ECL pump is anelectrical piston pump, controlled by the PLC output X17-9 which sends out pulses to thepump. Lubrication oil is then fed through a small plastic hose inside the air hose to the rockdrill, where the oil and air are mixed. A pressure reducing valve set to 5.5 bar limits theamount of air used for the ECL system. The ECL lubrication pressure gauge is located in thecabin. There are two sensor switches which control the ECL oil collection pressure, B381 forlimiting the low collection pressure and B382 for limiting the high collection pressure. TheECL oil collection system is optional.
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 169/368
Conditions for the ECL function:
• Switch S130 in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Impact switch S446A or S446B must be activated, to obtain percussion => D550-
CH9/10/ONResult in:• PLC output X17-9/ON => Y106 activated
Note : The ECL pump works for an extended time after the percussion is switched off.This time delay can be adjusted via the HEC3 display.
Adjustable parameters•
Time pulse – length of the pulse, i.e. the signaltime.• Pulses/minute – how many pulses there is per
minute• Extended time – total time of the pumping
cycle (after air flushing stop).
Drilling functions
HECL, DTH hammer lubrication system
Function The HECL pump Y165 is a hydraulic driven lubrication pump that starts pumping as soon asthe Impact/Flushing air is turned ON. The pump receives pulses from the HECL PLC outputX11-16 (30-40 pulses/min) in the electrical cabinet. Lubrication oil is then led through a ¼”hose to the rotation unit, where the lubricating oil and air is mixed. The HECL lubricationpressure gauge is in the cab.
Conditions for the HECL function:
• S130
L8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 170/368
Switch in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Impact switch S446A or S446B must be activated => D550-CH9/10/ONResult in:• PLC output X11-16/ON => Y165 activated
Note : The HECL pump works for an extended time after the percussion is switched off.This time delay can be adjusted via the HEC3 display.
Adjustable parameters• Time pulse – length of the pulse, i.e. the signal
time.• Pulses/minute – how many pulses there is per
minute• Extended time – total time of the pumping
cycle (after air flushing stop).
Drilling functions
HECL, COPROD head and sections lubrication system
Function The HECL pump Y165 is a hydraulic driven lubrication pump that starts pumping as soon asthe Flushing air is turned ON. The pump receives pulses from the HECL PLC output X11-16(30-40 pulses/min) in the electrical cabinet. Lubrication oil is then led through a ¼” hose tothe flushing air connection at the rock drill, where the lubricating oil and air is mixed. Thereis no pressure gauge for the HECL lubrication pressure.
Conditions for the HECL function:
• S130
L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 171/368
Switch in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Impact switch S446A or S446B must be activated, to obtain air flushing => D550-
CH9/10/ONResult in:• PLC output X11-16/ON => Y165 activated
Note : The HECL pump works for an extended time after the percussion is switched off.This time delay can be adjusted via the HEC3 display.
Adjustable parameters • Time pulse – length of the pulse, i.e. the signal
time.• Pulses/minute – how many pulses there is per
minute• Extended time – total time of the pumping
cycle (after air flushing stop).
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 172/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 173/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 174/368
Damper & DPC-I system
Damper & DPC-I system
DamperThe rock-drill damper circuit is supplied with oil from Pump1 through a constant flowregulator. The flow regulator is adjusted to correspond to a pressure of 25 bar at the damperhose connection on the rock-drill.
The damper pressure during drilling shows the actual feed force on the drill bit. The pressurecan be read on the pressure gauge in the cabin. During drilling, the damper pressure controlscertain logic valves, which in turn controls the impact pressure (hammer pressure). This isdescribed below as the DPC-I system.
Adj ti g th d
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 175/368
Adjusting the damper pressureAdjustment of the damper pressure must be done with the damper piston in its rested, forwardposition. To ensure this, the shank adapter can be pulled out to its most forward position.Adjustment of the damper pressure should only be done with the hydraulic oil has reachednormal working temperature, 40ºC (104ºF).
1. Connect a pressure gauge between the damperhose connection and the damper hose on therock-drill.
2. Start the diesel engine and let it run at 1500rpm.
3. Make sure that the shank adapter is in itsforward position, i.e. the damper piston is inits forward position.
4. Turn switch S130 to Drilling position.5. Loosen the lock screw (8b) and adjust thedamper pressure by turning the adjustmentscrew (8a) clockwise to decrease and anti-clockwise to increase the pressure.
6. Tighten the lock screw when the correct setting is achieved.
Read on the gauge on the damper connection the pressure should be:
COP 4050 & COP 4050CR, 25 barThe corresponding pressure read on the cabin gauge: (happens to be higher than the one read
th d ti b it h ll d )
Damper & DPC-I system
DPC-I System
FunctionThe DPC-I system (Damper Pressure Controlled Impact) controls the impact function by
sensing the damper pressure during drilling. Depending on the damper pressure, impact canbe allowed, stopped or changed between high and low impact pressure. This is done by anumber of logic valves in the rig hydraulic system.
• Logic-I. Prevents activation of impact if the damper pressure is below 45 bar, or stopsimpact if the damper pressure drops below 45 bar in case of, e.g., hose rupture, valvemalfunction or drilling into cavity.
• Logic J Stops impact if the damper pressure exceeds 120 bar in case of e g excessive
L7 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 176/368
Logic-J. Stops impact if the damper pressure exceeds 120 bar in case of, e.g., excessivefeed pressure or mechanical failure of the damper.
• Logic-A. During normal drilling with high impact pressure, the logic proportional valve Ais activated by the damper pressure through logic valve D. If the damper pressure fallsbelow the preset value of logic-A, it is deactivated. The Pump 1 pressure provided by thehigh impact relief valve 47f is then connected to the low impact relief valve 47e , thus the
low impact relief valve 47e controls the pump pressure.
ROC L7 40CR:• Logic-O. Allows activation of impact when the feed pressure has reached 45 bar and stops
impact when feeding backwards or entering a cavity in the rock.
Warning! Wronged adjusted damper pressure can cause damage to rock-drill, drill rig anddrill string. Adjustments should only be performed by a qualified Atlas Copcoservice technician.
Setting the DPCI systemThe DPCI system can be adjusted either in the workshop or on the drill site. Adjusting in theworkshop generally gives a more exact setting. On the other hand, adjusting during drillingcan result in a setting well adapted to the rock conditions and other system settings.In general, logic-I and logic-O should be set as high as possible without making it difficult to
start impact.
ROC L7 40 :
Damper & DPC-I system
Setting during drilling – L7 40
Logic-I, Setting during drilling:
1. Check that the damper pressure is adjusted according to “Adjusting the damper pressure”.
2. Start drilling on low impact pressure and collaring feed pressure.3. Adjust the feed pressure slowly towards 0 while observing the damper pressure gauge.
4. When the damper pressure drops below 45 bar as a result of the low feed pressure, impact should bestopped automatically.
5. If needed, adjust logic-I CW to increase the setting or CCW to decrease it.
6. Test the function by starting drilling on low impact pressure and collaring feed pressure. When the drillcradle comes to a stop against the mechanical end stop, impact should shut of immediately. If not, thesetting of logic-I should be increased.
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 177/368
g g
NOTE! The setting of logic-I should be the highest possible without making it difficult to start impact. Thismeans that high collaring feed and damper pressures calls for a higher setting of logic-I.
Logic-A, Setting during drilling:
1. Check that the damper pressure is adjusted according to “Adjusting the damper pressure”.
2. Start drilling. Make a good collaring, and then activate high impact pressure.
3. Slowly decrease the feed pressure while observing the damper pressure gauge.
4. The impact pressure should change from high to low when the damper pressure drops below 50 bar.
5. If needed: Adjust logic-A CCW to lower the setting and CW to increase it.
Logic-J, Setting during drilling:
1. Check that the damper pressure is adjusted according to “Adjusting the damper pressure”.
2. Start drilling on low impact pressure.3. Increase the feed pressure towards maximum while observing the damper pressure gauge.
4. When the damper pressure exceeds 120 bar, impact should be stopped automatically.
5. If needed, adjust logic-J CCW to lower the setting or CW to increase it.
NOTE! During this adjustment there is an increased risk of getting stuck in the hole due to the increased feed pressure. NOTE! In soft rock conditions it can be difficult to force the damper pressure high enough. In this case thedamper pressure regulator can be adjusted temporarily to 120 bar.
40
Damper & DPC-I system
6. Verification: Increase and decrease the damper pressure a few times in order to verify that impact isstopped when the damper pressure is below 45 bar.
7. De-activate impact and turn off the diesel engine.
8. Tighten the lock nut on logic-I without changing the setting and reconnect the impact pressure hose onthe rock-drill.
9. Adjust the damper pressure according to “Adjusting the damper pressure”. Verify through test drillingthat impact can not be activated unless the drill bit is pressed against the rock.
Logic-A, Setting in workshop:
1. Disconnect and plug the impact pressure hose on the rock-drill.
2. Start the diesel engine, increase the rpm to 1500 and turn switch S130 to Drilling position.
3 Adjust the damper pressure to 50 bar read on the damper pressure gauge in the cabin
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 178/368
3. Adjust the damper pressure to 50 bar, read on the damper pressure gauge in the cabin.
4. Activate drill rotation.
5. Activate high impact pressure. Check the pressure on the impact pressure gauge in the cabin.
6. Slowly adjust logic-A in and out to find the activation point where the impact pressure changes fromhigh to low. CW increases the activation point and CCW lowers it. Finally, adjust slowly CW until theimpact changes to low.
7. Verification: Increase and decrease the damper pressure a few times in order to verify that the impactpressure changes when the damper pressure passes 50 bar.
8. De-activate impact and turn off the diesel engine.
9. Tighten the lock nut on logic-A without changing the setting and reconnect the impact pressure hose onthe rock-drill.
10. Adjust the damper pressure according to “Adjusting the damper pressure”. Verify through test drillingthat the impact pressure changes from high to low when the damper pressure drops below 50 bar if the
feed pressure is lowered.
Logic-J, Setting in workshop:
1. Disconnect and plug the impact pressure hose on the rock-drill.
2. Start the diesel engine, increase the rpm to 1500 and turn switch S130 to Drilling position.
3. Adjust the damper pressure to 120 bar, read on the damper pressure gauge in the cabin.
4. Activate low impact pressure. Check the pressure on the impact pressure gauge in the cabin.
5. Slowly adjust logic-J in and out to find the activation point where the impact pressure disappears fromthe gauge CW increases the activation point and CCW lowers it Finally adjust slowly CW until the
Damper & DPC-I system
Related logic-valves• Logic-D. It is activated by the pilot signal for drill rotation anti-clockwise. This means
that the DPC-I system is only in effect when drill rotation is active. When logic-D isclosed to damper pressure it is open to the Pump 1 system pressure. This means that whenrotation is not active, the impact pressure will be according to the position of the impactcontrol switch S446A/B, irrespective of the damper pressure.
• Logic-C. It is activated through Y101B (impact low pressure activated) or when feedingbackwards. This excludes logic-E from getting activated. Consequently, in these casesthere can only be low impact pressure. Feeding backwards and activating impact is thecase when back hammer function is switched on. It does not matter which impact button(high or low) is pushed, the impact pressure will stay low anyway.
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 179/368
Note : Impact pressure has the same pressure as the pump pressure, since impact pressure
comes from pump 1. In the diagram they are being distinguished by two different colours toidentify their own circuits.
Damper & DPC-I system
Setting during drilling – L7 40CR
Logic-I, Setting during drilling:
1. Check that the damper pressure is adjusted according to “Adjusting the damper pressure”.
2. Disable logic-O by turning its adjustment screw 3-4 turns CCW. If this is not done, impact will bestopped due to too low feed pressure during the setting of logic-I.
3. Start drilling on low impact pressure and collaring feed pressure.
4. Adjust the feed pressure slowly towards 0 while observing the damper pressure gauge.
5. When the damper pressure drops below 45 bar as a result of the low feed pressure, impact should bestopped automatically.
6. If needed, adjust logic-I CW to increase the setting or CCW to decrease it.7 V if th t i t t b ti t d ith t k t t d th t i t b ti t d h th
L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 180/368
7. Verify that impact can not be activated without rock contact, and that impact can be activated when thebit is pressed against the rock with collaring feed pressure.
8. Readjust logic-O by turning its adjustment screw CW the same number of turns as it was turned CCWin point 1, or according to instruction.
9. Test the function by going into the display and change the setting for “impact stop” (position M0) byadding 0.5 m in menu “Rapid feed stop”. This will deactivate the automatic impact stop. Write downthe original setting! Impact should then cease immediately when the rock drill cradle stops against themechanical end stop. If not, the setting of logic-I should be increased.
10. Re-enter the parameter setting for “impact stop”.
NOTE! The setting of logic-I should be the highest possible without making it difficult to start impact. Thismeans that high collaring feed and damper pressures calls for a higher setting of logic-I.
NOTE! Excessive drilling with too low feed pressure can cause damage to COPROD sections and rockdrill.
Logic-O, Setting during drilling:
1. Start drilling on low impact pressure and your normal collaring feed pressure.
2. Adjust logic-O CW until impact is stopped and then CCW until impact just starts again.
3. Reverse the feed direction. Impact should stop immediately without free hammering.
4. Restart drilling and check that impact starts easily. If not, the setting of logic-O may need to belowered slightly.
NOTE! The setting of logic-O should be the highest possible without making it difficult to start impact.
L i A S i d i d illi
Damper & DPC-I system
3. Increase the feed pressure towards maximum while observing the damper pressure gauge.
4. When the damper pressure exceeds 120 bar, impact should be stopped automatically.
5. If needed, adjust logic-J CCW to lower the setting or CW to increase it.
NOTE! During this adjustment there is an increased risk of getting stuck in the hole due to the increased feed pressure. NOTE! In soft rock conditions it can be difficult to force the damper pressure high enough. In this case thedamper pressure regulator can be adjusted temporarily to 120 bar.
Setting in workshop
Logic-I, Setting in workshop:
1. Disconnect and plug the impact pressure hose on the rock-drill.
L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 181/368
2. Start the diesel engine, increase the rpm to 1500 and turn switch S130 to Drilling position.
3. Adjust the damper pressure to 45 bar, read on the damper pressure gauge in the cabin.
4. Activate drill-feed forward. This is required to enable activation of impact on COPROD rigs (logic-O).When the rock-drill almost reaches its lower end position, impact will be stopped by the impact stopcheck. This can be avoided by adding 0.5 m to the parameter for “impact stop”. Write down theoriginal setting!
5. Activate low impact pressure. Check the pressure on the impact pressure gauge in the cabin.
6. Slowly adjust logic-I in and out to find the activation point where the impact pressure disappears fromthe gauge. CW increases the activation point and CCW lowers it. Finally, adjust slowly CCW until theimpact pressure appears on the gauge again.
7. Verification: Increase and decrease the damper pressure a few times in order to verify that impact isstopped when the damper pressure is below 45 bar.
8. De-activate impact and feed and turn off the diesel engine.
9. Tighten the lock nut on logic-I without changing the setting, re-enter the parameter setting for “impactstop” and reconnect the impact pressure hose on the rock-drill.
10. Adjust the damper pressure according to “Adjusting the damper pressure”. Verify through test drillingthat impact can not be activated unless the drill bit is pressed against the rock, and that impact can beactivated when the bit is pressed against the rock with collaring feed pressure.
Logic-O, Setting in workshop:
1. Disconnect and plug the impact pressure hose on the rock-drill.
2. Start the diesel engine, increase the rpm to 1500 and turn switch S130 to Drilling position.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 182/368
Damper & DPC-I system
9. Tighten the lock nut on logic-J without changing the setting, re-enter the parameter setting for “impactstop” and reconnect the impact pressure hose on the rock-drill.
10. Adjust the damper pressure according to “Adjusting the damper pressure”. Verify through test drillingthat impact is stopped when the damper pressure exceeds 120 bar if the feed pressure is increased to
maximum.
Related logic-valves• Logic-D. It is activated by the pilot signal for drill rotation clockwise. This means that the
DPC-I system is only in effect when drill rotation is active. When logic-D is closed todamper pressure it is open to the Pump 1 system pressure. This means that when rotationis not active, the impact pressure will be according to the position of the impact controlswitch S446A/B, irrespective of the damper pressure.
• Logic-C. It is activated through Y101B (impact low pressure activated).
L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 183/368
Note : Impact pressure has the same pressure as the pump pressure, since impact pressurecomes from pump 1 In the diagram they are being distinguished by two different colours to
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 184/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 185/368
Pilot lever
Y175
Q
BPump p.
F e e
d
p .
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 186/368
2
I
O
J
Y101AY101B
D
C
low
A
Y101C
DPCI on ROC L7 40
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 187/368
3
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 188/368
Dust collector, DCT
Dust collector, DCTConditions for the DCT suction functions:
• Switch S130 in drilling position => D552-CH1/ON• Sensor B118 activated, RHS arm in carousel => PLC input X10-5/ON• Compressor load switch S180 must be on => D552-CH9/ON• Flushing/Impact switch S446A or S446B must be activated, in either flushing or
impact mode => D550-CH9/10/ON• Switch S181 must be in suction position => D552-CH12/ON
The DCT system includes functions for starting the fan, controlling suction ON/OFF and
cleaning the filters. The hydraulic power is supplied from pump 3.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 189/368
DCT hydraulic systemWhen the drilling/tramming switch S130 is in drilling position, it activates DCT fan motorsolenoid Y250 . This means that the fan is running as soon as the switch is in drilling positionbut there will not be any suction until the fan housing outlet is opened. The running speed ofthe DCT fan motor 14 is set by the pressure relief valve 13a to around 5800 rpm @ 150 barfor L7 40 , L7 40 CR ; and to around 5000 rpm @ 150 bar for L8 30 .The speed can be changed by adjusting the screw on pressure relief valve 13a.
When the fan motor is stopped by turning switch S130 away from drilling position, the pilotoperated relief valve 13b acts as a brake. It creates counter pressure in the return line when itis no longer pilot opened by the pump pressure and is set to stop the fan wheel in 8 seconds.The stop time can be changed by adjusting the screw on pressure relief valve 13b.
The fan motor drain connection is fitted with restrictor 15 to keep a sufficient amount of oilinside the housing for cooling purposes.
Dust collector, DCT
DCT electrical system• Starting the DCT suctionThe fan housing outlet is operated by a hydraulic cylinder controlled by solenoid valve Y253 .Y253 is controlled by PLC output X18-7, and will be activated if S181 is ON (input D551-
CH12) and S446 is in reduced or full air/impact position (input D550 CH-9/10). To activateflushing air only, press S446A for shorter than 0.5 seconds, to start impact, press S446A forlonger than 0.5 seconds. Normally, switch S181 is kept in the ON position to allow thesuction to be automatically controlled by the impact switch.
• DCT filter cleaningWhen PLC output X18-7 is activated, it also activates the four filter cleaning valves Y251A-
D alternately. The filter cleaning valves quickly opens and closes to create pressure shocks ofcompressed air to clean the filters.The length of each cleaning pulse can be adjusted in the “Time pulse” data entry field in the
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 190/368
g g p j p ydisplay. The time between each pulse can be adjusted in the “Pulses/minute” data entry fieldin the display. The pulse time is set to 0.5 seconds (can be set up to 1 second) and the pulsecan be set between 6 to 20 times per minute, depending on moisture of the drill dust. If thedust is moist the pulse is set to maximum 20 times, if the drill dust is very dry the pulse timeis set to minimum 6 times. Factory setting is 10 pulses/minute.
When the DCT switch S181 is OFF or when impact is shut off by S446 , the control systemactivates valves Y251A-D simultaneously to clean the DCT filters. The cleaning time can beadjusted in the “Extended time” data entry field in the display.
DCT air systemThe air supply to the DCT is limited to 7 bar by pressure reducing valve and protected by a8.5 bar safety valve. Solenoid valves Y251A-D opens alternately to clean the DCT filters.
DCT adjustable parameters• Time pulse – length of the pulse, i.e. the
signal time.• Pulses/minute – how many pulses there is per
minute• Extended time – total time of the cleaning
DCT System
Input / Signal
Switch S130 drilling positionCompressor load switch S180 on
Flushing/impact switch S446A or B on
DCT switch S181 on
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 191/368
1
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 192/368
Y250
Y253
Y251A
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 193/368
3
DCT fan on +hatch open
D C T
- h a t c h
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 194/368
4
Y253
Y250
170 bar
100 bar
Pump 3
Y251A
Pressure vessel
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 195/368
5
DCT filter 1DCT filter 2DCT filter 3DCT filter 4
Y251A-D
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 196/368
6
DCT off,cleaning
D C T
- h a t c h
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 197/368
7
Y250
Y251A Y251B
Y251DY251C
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 198/368
8
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 199/368
9
Y250
100 bar
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 200/368
Protective functions
Protective functions
RPC-F system – L7 40 RPC-F, Rotation Pressure Controlled Feed.When drilling, the drill string must have a certain rotation torque in order to keep all the rodcouplings tightened. Loosened joints increases the loss of impact energy transmitted to thedrill bit and leads to damage of the threads with drill steel breakage as a possible result.However, too high rotation torque also has disadvantages:
• The couplings can get “over-tightened”, which makes itdifficult to loosen the couplings when withdrawing the drillstring.
• Higher load on the rock drills rotation driver, thus shorterlife length.
• Jerky rotation could cause the anti-jamming to activate
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 201/368
often.
Rotation torque is achieved by feed force, and will varydepending on different rock layers. The RPC-F system will
adapt the feed force during drilling, maintaining only therequired rotation torque. The RPC-F valve, 44 , senses thepressure in the rotation circuit (rotation torque) and varies thefeed pressure between the settings of the high feed pressurevalve 47b and the low feed pressure valve 47a to maintain therequired rotation torque.
Protective functions
Anti-Jamming system
Devices The drill rig is equipped with two types of anti-jamming device.
•
Flushing air flow switch – L740
, L740
CR• Rotation pressure switch – All typesBoth changes the direction of feed from forward to backward, if activated by insufficientflushing air or too high rotation pressure, in order to avoid getting stuck.
Logic function of drill leverSince the anti-jamming inverts the feed direction, pulling the drill lever for feeding backwardswould result in feed forward movement. To avoid this there is a pressure switch, B262 ,connected to the pilot pressure line for feed backwards. B262 is connected to PLC input X16-16, which, when active, inhibits the anti-jamming output X11-11.
Fl hi i fl i h B142 L7 40 L7 40CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 202/368
Flushing air flow switch, B142 – L7 40 , L7 40CRConditions for the flow switch activated anti jamming function:
• Switch S130 in drilling position => D552-CH1/ON•
SensorB118
activated, RHS arm in carousel =>PLC input X10-5/ON• Compressor load switch S180 must be on => D552-CH9/ON• Flushing air switch S100 must be in full flushing position => D551-CH1/ON • Flushing/Impact switch S446A or S446B must be activated, in either flushing or
impact mode => D550-CH9/10/ON• Pressure switch B262 not activated => PLC input X16-16/OFF• Signal from flow switch B142 => PLC input X11-7/ON
Result in:• PLC output X11-11/ON => Solenoid Y109 activated
NOTE: The anti-jamming will be activated for at least 2 sec.
The flow switch is connected after the flushing airvalves and senses the pressure drop over arestriction, venture pipe, in the flushing air line.The difference in pressure between the two
connections is keeping the contact of the flowswitch open.
Protective functions
Adjusting B142 – L7 40 , L7 40CR The flushing air flow switch can only be set during drilling and only with full flushing airactivated.
1. Unscrew the cover of the flow switch.2. Drill almost down to the greatest depth that will be drilled on the site. Make sure full
flushing is activated, switch S100, position (a). (see figure below)3. Turn the adjustment screw (1) anti-clockwise until the rock-drill starts to back up. The
higher the figure on the adjustment scale, the more sensitive the flow switch will be.Factory setting is 30 mbar.
4. Turn the adjustment screw (1) back clockwise until the rock-drill returns downwards.5. Drill another whole to verify that the flow switch is not unintentionally activated due
to too sensitive setting. If so, back the adjustment screw off a little bit more.
6. Assemble the cover of the flow switch.When changing dimension of drill-bit or drill steel, or if the hole depth is changed, it can benecessary to re-adjust the flow switch in order to maintain a good anti-jamming protection.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 203/368
Rotation pressure switch, B134 – L7 40 , L7 40CR, L8 30 Conditions for the rotation pressure activated anti-jamming function:
• Switch S130 in drilling position => D552-CH1/ON• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Impact switch S446A or S446B must be activated => D550-CH9/10/ON• Pressure switch B262 not activated => PLC input X16-16/OFF• Signal from pressure switch B134 => PLC input X11-6/ON
L7
S100a
b
L7 CR
S100
a
b
Protective functions
Adjusting B134Setting of the activation pressure of the anti-jamming is done on the pressure switch B134itself. The activation pressure can be difficult to adjust during drilling because it is usuallydifficult to force the rotation pressure high enough. In stead, a simulation can be done.Warning! During the setting, the rock-drill will reverse automatically.1. Turn the knob for adjustment of the drill rotation speed anti-clockwise until the spring
pressure is released. The rotation speed will now be 0 rpm.2. For CR and DTH: Feed the rock drill down until the coupling sleeve of the drill steel is in
the upper break out table. Close the upper break out table to lock the sleeve.For TH: Feed the rock drill down until the drill bit is in the upper drill steel support. Closethe upper drill steel support to lock the drill bit.
3. Activate drill rotation.
4. Activate drill feed.5. Slowly turn the rotation speed controlclockwise while observing the drill rotationpressure gauge. When the pressure exceeds the
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 204/368
p g g ppreset value of the pressure switch B134, thefeed direction will change. This can be seen asthe feed pressure turns to 0 and the rock drilltries to pull out of the drill steel support.
6. Turn the rotation speed control anti-clockwiseto lower the rotation pressure and allow the feedto change back to downwards.
7. If the setting needs to be changed this can bedone by turning the adjustment screw on B134clockwise to increase the activation pressure oranti-clockwise to decrease it.
8. Repeat point 1 – 6 to verify the new setting.9. Re-adjust the rotation speed to normal.
Feed & pump pressure during anti-jamming – L7 40 , L7 40CR Impact/pump 1 pressure:When feed backwards is automatically activated during anti-jamming, PLC deactivatesoutput X11-9 for impact activation. This deactivates Y101A, and leaves logic valve B idlehence blocking the access to the pressure relief valves 47e and 47f which control the pump
1 pressure. The pump 1 system pressure is then limited by pressure relief valve 4d ,together with the delta-p pressure, pump 1 will be working at 250 bar (LS return line +
RPCF for L7 40
Maintaining only the required rotation torque for drilling
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 205/368
1
Anti-jamming
Two anti-jamming devices – Monitoring of the flushing air flow (L7 40 , L740 CR)
– Monitoring of the rotation pressure
Inverts the feed direction incase of insufficient air flow or too highrotation pressure
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 206/368
2
Factory settings:
– 30mBar pressure drop over the venturi – 80 Bar rotation pressure
Anti-jammingInput / Signal
S130/1 - D552,CH 1/ONS180/A3 – D552, CH 9/ON
S446/A/B – D550, CH 9/10/ON
S100/A3 – D551, CH 1/ON
X11-7 B142
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 207/368
3
X11-5 B134
Output on indicator cardX11-11 Y109
B142
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 208/368
4
Y116Y115
M a
i n a
i r f l o w
B134
Y169
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 209/368
5
Y121A
Pump 4
B142
L740 , L7 40 CR
B134
L740 , L7 40 CR, L8 30Page 28
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 210/368
6
Y109
L740 , L7 40 CR, L8 30
Anti-jamming
Page 27
Page 35
Y109 is activated by
either B142 or B134.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 211/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 212/368
B262
Pilot lever
CY109Feed backwards
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 213/368
9
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 214/368
Length measurement
Length measurement
Hole depth measurementData from pulse sensor B172 is handled for measuringhole length, with stop signal for drilling when set lengthis reached. A choice can be made between hole depthand hole length which stops the drilling.
The first row in the menu view to the right (figure 2, 3)shows actual length/depth of the hole.
• Hole length is the actual number of metres thathave been drilled.
• Hole depth is the vertical distance fromground level to the bottom of the hole.
Hole length and hole depth can be set on a menu, pushenter key according to the selection on figure 1.
Figure 1
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 215/368
The value in the square box shows the required holelength/hole depth. The length or depth can be set from0.1m- 99.9m . When the hole has reached the requireddepth/length the PLC automatically sets the drill output“low”. The drilling can continue by restarting thedrilling functions.
The second row displays the penetration rate.The third row displays the position of the drill bit.
EXAMPLE: If the hole is 10m the first row shows10m. If the drill steel is run backward the drill bit’sposition starts to count backward to inform the operatorof the distance from the bit to the bottom of the hole.
: Reset of the hole depth
: Numbers of performed couplings
Figure 2
Figure 3
Length measurement
Basic conditions for measurement:• Correct length of drill steel must be chosen in the drill steel menu.• The length measurement system must be reset before the start of drilling.• Impact must be activated for measuring hole length/depth. Bit position will be
measured even without impact.
During rod handling, the HEC system pause the drill length/depth measuring. This means thatnegative distance created when backing up to add a new rod is not taken into consideration bythe system.The start of the pause is defined by a signal coming from a pressure switch B128 along withother conditions (see below). B128 is activated when unthreading the rock drill from the rod.
Conditions for blocking:• Upper drill steel support closed (for RHS 102); lower break out table closed (for RHS140).
• Unthreading activated => B128 activated. • Impact interrupted.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 216/368
Impact interrupted.
To exit standby and re-enter measuring mode after adding a drill steel, the followingconditions must be fulfilled.
Conditions for restarting measurement after rod handling:• Upper drill steel support opened (for RHS 102); lower break out table opened (for
RHS 140). • Impact activated. • The cradle must be retracted to the upper position, i.e. 90% of the length for the
chosen rod.
Drill stop activation for reached depthDrill stop activation for reached depth is a build-in function of the HEC system. When the
drilled metre on the display equals to the metre that has been entered , alldrilling functions will be stopped. The drill lever is then automatically shifted to rapidfeed/threading mode.
Rod Handling System, RHS 102
Rod Handling System, RHS 102
Conditions common for all RHS functions:
• Switch S130 in drilling position => D552-CH1/ON• Switch B379 (operator in chair) must be activated =>
D550-CH1/ON• The impact control switch S446A/B must be OFF =>
D550-CH9/10/OFF
The functions of the different rod handling movements areelectrically operated by the RHS control lever S111 . The
control lever sends a signal to the PLC which, when the rightinputs are present, activates the corresponding hydraulicvalve in order to perform one of the following movements:
RHS control lever S111:ROD CAROUSEL ROD GRIPPER
S111
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 217/368
RODTRANSFER
CAROUSELROTATION
ROD GRIPPER
-To carousel -Clockwise -Hard grip-To drill centre -Anti-clockwise -Guide grip
-Open
The hydraulic power is supplied from Pump 1 and is limited to 200 bar by pressure reducingvalve 91 . Some functions have individual pressure reducers to further limit the pressure.
d f
RHS arm → drill centre/hard grip(Note : lever has a latch in this position)
Carousel rotationanti-clockwise
Carouselrotation
clockwise
RHS arm → carousel/hard grip
Button for opening gripper claws
Rod Handling System, RHS 102
Control lever S111 is mechanically latched during this movement, that is to say one push onthe lever and the lever stays there, instead of a spring return to centre position. With the leverin position it will carry out the whole movement until the rod is moved into the drill centre.The function has been introduced to prevent grippers to automatically switch to loose gripmoved into the drill centre.
Loose grip can be achieved by pulling the lever back to the neutral position, when the armreached its end position (drill centre).
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 218/368
Hard grip stage S111 back to neutral Loose grip stage
NOTE! Always put the rod grippers in loose grip before the threads meet in order to let therod in the rod gripper rotate. The threads will otherwise be easily damaged.
Additional conditions:
- Sensor B118 activated, PLC input X10-5/ON. (Arm in carousel.) - The rod grippers should be in hard grip during this movement as the PLC output X12-
d h l h l d f h
Rod Handling System, RHS 102
To carousel without a rod
CLAIM: The carousel could still have rods in it or not, arm has to move back to carousel inorder to get the next rod to drill; also to allow drilling.
Additional conditions:- Sensor B120 activated, PLC input X10-3/ON. (Arm in drill centre.) - RHS control lever S111 top button pushed, input D551-CH6/ON. The rod grippers
should be in open grip during this movement.- RHS control lever S111 to position (a), input D551-CH2/ON. When all the conditions are met, this function will take place:• Solenoid valve Y300 will be activated by PLC output X12-3. (Rod grippers are open.)• Solenoid valve Y301A will be activated by PLC output X12-4. The cylinder speed is
limited by restrictors 82 . (Arm transfer towards carousel starts.)
When the rod transfer arm have reached position carousel, sensor B118 will be activated,PLC i t X10 5/ON Thi lt i
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 219/368
PLC input X10-5/ON. This results in:• PLC output X12-4/ON, Y301A activated. (Arm transfer towards carousel stops
mechanically.)
SEQUENCE COMPLETE
To carousel with a rod
CLAIM: The carousel empty or not, rods are supposed to be put back to the carousel.
Additional conditions:- Sensor B120 activated, PLC input X10-3/ON. (Arm in drill centre.) - The rod grippers should be in hard grip during this movement as the PLC output X12-
8 and X12-3 are OFF. This is also the normal condition of the grippers.- RHS control lever S111 to position (a), input D551-CH2/ON. When all the conditions are met, these two functions will take place in its order:• Solenoid valve Y301A will be activated by PLC output X12-4. The cylinder speed is
limited by restrictors 82 . (Rod transfer towards carousel starts.)
Rod Handling System, RHS 102
To drill centre without a rod
CLAIM: The carousel could be empty or not, the grippers are in hard grip state in carousel.This is the case when drilling has been done, rods are being pulled out and need to
be picked up from the drill centre.
Loose grip is needed first when the grippers have been moved into the drill centre, becauseonly loose grip can allow the upper rod to rotate out of the lower rod/drill bit which is beingheld in the drill steel support. Loose grip can be achieved by pulling the lever to the neutralposition. Manual switching is needed here since the lever is latched in this position.
Once the upper rod has been unthreaded, hard grip needs to be activated in order to allow therock drill to be unthreaded. Hard grip can be achieved by pulling the lever backwards to the“arm to drill centre” position, thus breaking the conditions for loose grip.
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 220/368
Loose grip stage S111 to arm to drill centre Hard grip stage
Additional conditions:Sensor B118 activated PLC input X10 5/ON (Arm in carousel )
Rod Handling System, RHS 102
Carousel rotationAdditional conditions:• The rod gipper arms must be in carousel position, sensor switch B118 ON, PLC input
X10-5/ON.• RHS control lever S111 , top button pushed, input X550-CH6/ON.• RHS control lever S111 , to position (c) or (d), input X550-CH4 or CH5/ON.The carousel stop positions are determined by the two sensors B182 (CCW) and B183 (CW).The carousel rotation motor solenoid valve Y303A/B is activated by PLC output X15-2(CWW) and X15-1 (CW).When rotation is activated it will continue until the corresponding sensor is activated, givinginput to PLC X14-8 and X13-1 respectively. The rotation speed is limited by restrictors 84 .To facilitate the rotation of the carousel, the rod grippers must be the rod grippers must be at
the carousel position to allow rotation, i.e. B118 activated.
Rod grippersThere are three rod gripper positions, which are controlled bysolenoid valves Y300 and Y306 .
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 221/368
o Hard gripAdditional conditions:None. Hard grip is the normal state of the grippers. None of thesolenoid valves are activated with the result that system pressure,200 bar, is acting to keep the gripper closed.
o Open grippersAdditional conditions:• RHS control lever S111 , top button pushed, input X550-
CH6/ON.Solenoid valve Y300 is activated by PLC output X12-3.
o Guide grip (loose grip)Additional conditions:• RHS control lever S111 must be in middle position, no signal
from the RHS switch to the PLC.• Sensor B120 activated, PLC input X10-3/ON.Guide grip can only be achieved when the rod grippers are in thedrill-centre position and when there is no signal from RHS switchto the PLC.Solenoid valve Y306 in the guide grip valve block 80 , is activated
Rod Handling System, RHS 102
Sleeve retainer (Option)Additional conditions:• Sleeve retainer switch S182 ON, input D551-CH13/ON.Solenoid valve Y309 is activated by PLC output X15-3. The cylinder speed is limited byrestrictors 83 . The sleeve retainer can only be folded out when the rod grippers are in drillcentre position and in hard grip mode. The rod transfer movements which include “arm tocarousel” function are electrically blocked as long as the sleeve retainer is activated.
Drill steel supports & suction hoodConditions for these functions:• The Drilling/Tramming switch S130 must be in drilling position
o Drill steel supports, upper and lower
The drill steel supports are controlled by switches S119 (upper) and S187 (lower), whichoperates solenoid valves Y361A-B and Y350A-B respectively. The cylinder speed islimited by restrictors 85 and 86 .o Suction hoodThe suction hood is controlled by switch S167 , which operates solenoid valve Y357 . The
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 222/368
hydraulic pressure downwards is limited by pressure reducing valve 88 set to 40 bar, andthe cylinder speed is limited by restrictor 87 .
NOTE: It’s important that during drilling, the drill steel supports should be carefully operatedto prevent the drill rods colliding with them.
Service winch (Option)The service winch is a pure hydraulic function that works aside of the PLC. Solenoid valveY208 controls the moving direction of the winch, and it is activated by a lever that sits on thelower drill steel support.
RHS 102 – L7 40
Input / Signal
Switch S130 in Drilling pos.Operator in chair switch B379
Flushing/impact switch S446A or B off
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 223/368
1
RHS 102 – L7 40
Input / SignalS130/1 - D552, CH 1/ON
B379 - D550, CH 1/ON
S446A/B - D550, CH 9/10/OFF
S111 - D551, CH 2/3/4/5/6/ON
X10-5 B118X10-3 B120
X15-2 B182
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 224/368
2
X15-1 B183
Output on indicator cardX17-1 Y301A/B
X13-11 Y303A/B
X12-3 Y300
X12-8 Y306
1 B118
L740
Page 33
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 225/368
3
B120
Y301BRod transfer from carousel
1
2
Page 31
Page 41
200 bar
1 )
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 226/368
4
Y301B
R H S ( f r o m
p u m p
1
B182 2
L740
Y303A 1 2 Rotation stops for 1 second.
Page 41
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 227/368
5
2
Page 32 Carousel rotation CCW
1 )
200 bar
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 228/368
6
R H S ( f r o m
p u m p
1
Y300
Y303A
1 )
Y306
200 bar
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 229/368
7
R H S ( f r o m
p u m p
1
Y300
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 230/368
Rod Handling System, RHS 140
Rod Handling System, RHS 140
Conditions common for all RHS functions:
• Switch S130 in drilling position => D552-CH1/ON• Switch B379 (operator in chair) must be activated =>
D550-CH1/ON• The impact control switch S446A/B must be OFF =>
D550-CH9/10/OFF
The functions of the different rod handling movements areelectrically operated by the RHS control lever S111 . The control
lever sends a signal to the PLC which, when the right inputs arepresent, activates the corresponding hydraulic valve in order toperform one of the following movements:
RHS control lever S111:RODTRANSFER
CAROUSELGATE
CAROUSELROTATION
RODGRIPPER
GRIPPERROTATION
L8 , L7 CR
S111
Figure: example, L8 30 left panel
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 231/368
TRANSFER GATE ROTATION GRIPPER ROTATION-To carousel -Open -Clockwise -Hard grip -To carousel-To drill centre -Closed -Anti-clockwise -Guide grip -To drill centre
-Open
The hydraulic power is supplied from Pump 1 and is limited to 200 bar by pressure reducingvalve 97 . Some functions have individual pressure reducers to further limit the pressure.
RHS arm → drill centre/hard grip(Note : lever has a latch in this position)
Carousel rotationanti-clockwise
Carouselrotation
clockwise
RHS arm → carousel/hard grip
Button for opening gripper claws
Rod Handling System, RHS 140
To drill centre with a tube
CLAIM: The carousel loaded, the grippers are in the carousel holding on to the tube which isgoing to moved, the initial holding state should be hard grip.
Control lever S111 is mechanically latched during this movement, that is to say one push onthe lever and the lever stays there, instead of a spring return to centre position. With the leverin position it will carry out the whole sequence until the tube is moved into the drill centre.The function has been introduced to prevent grippers to automatically switch to loose gripwhen moved into the drill centre.
Loose grip can be achieved by pulling the lever back to the neutral position, when the armreached its end position (drill centre).
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 232/368
Rod Handling System, RHS 140
Additional conditions:
- Sensor B118 activated, PLC input X10-5/ON. (Arm in carousel.)
- The rod grippers should be in hard grip during this movement as the PLC output X12-8 and X12-3 are OFF. This is also the normal condition of the grippers.
- RHS control lever S111 to position (b), input D551-CH3/ON.
When all the conditions are met, these two functions will take place in its order:• Solenoid valve Y310 will be activated by PLC output X15-4. The cylinder speed islimited by restrictors 86 . (Carousel door opens.)
• Solenoid valve Y301B will be activated by PLC output X12-5. The cylinder speed islimited by restrictors 82 . (Tube transfer towards dill centre starts.)
When the tube transfer arm has reached the position between the carousel and drill centre,sensor B119 will be activated, PLC input X10-2/ON. This results in:
• PLC output X12-5/OFF, Y301B deactivated. (Tube transfer towards drillcentre stops.)
• PLC output X16-12/ON, Y311B activated. (This will rotate the rod grippersfrom facing the carousel to facing the drill centre.)
The gripper rotation sequence will continue for 3 seconds, after that:
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 233/368
The gripper rotation sequence will continue for 3 seconds, after that:• PLC output 16-12/ON, Y311B activated. (Even though Y311B is activated,
but the gripper rotation has stopped mechanically.)• PLC output X15-4/OFF, Y310 deactivated. (Carousel door closes.)• PLC output X12-5/ON, Y301B activated again. (Tube transfer towards
drill centre continues.)
When the tube transfer arm have reached position drill centre, sensor B120 willbe activated, PLC input X10-3/ON. This results in:
• PLC output X12-5/ON, Y301B activated. (Tube transfer towards drillcentre stops mechanically.)
• PLC output X16-12/ON, Y311B activated. (Gripper rotation has stoppedmechanically.)
• PLC output X12-8/OFF and X12-3/OFF, Y306 and Y300 deactivated.(Hard grip)
SEQUENCE COMPLETE
Rod Handling System, RHS 140
To carousel without a tube
CLAIM: The carousel could still have tubes in it or not, arm has to move back to carousel inorder to get the next tube to drill; and/or moving back to carousel to allow drilling.
Additional conditions:- Sensor B120 activated, PLC input X10-3/ON. (Arm in drill centre.)
- RHS control lever S111 top button pushed, input D551-CH6/ON. The rod grippersshould be in open grip during this movement.
- RHS control lever S111 to position (a), input D551-CH2/ON.
When all the conditions are met, this function will take place:• Solenoid valve Y310 will be deactivated by PLC output X15-4. (Carousel door is
closed.)• Solenoid valve Y300 will be activated by PLC output X12-3. (Rod grippers are open.)• Solenoid valve Y301A will be activated by PLC output X12-4. The cylinder speed is
limited by restrictors 82 . (Arm transfer towards carousel starts.)
When the tube transfer arm has reached the position between the carousel and drill centre,
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 234/368
psensor B119 will be activated, PLC input X10-2/ON. This results in:
•
PLC output X12-4/OFF, Y301A deactivated. (Arm transfer towards carouselstops.)• PLC output X18-1/ON, Y311A activated. (This will rotate the rod grippers
from facing the drill centre to facing the carousel.)
The gripper rotation sequence will continue for 3 seconds, after that:• PLC output 18-1/ON, Y311A activated. (Even though Y311A is activated,
but the gripper rotation has stopped mechanically.)• PLC output X12-4/ON, Y301A activated again. (Arm transfer towards
carousel continues.)
When the tube transfer arm have reached position carousel, sensor B118 will beactivated, PLC input X10-5/ON. This results in:
• PLC output X12-4/ON, Y301A activated. (Arm transfer towardscarousel stops mechanically.)
• PLC output X18-1/ON, Y311A activated. (Gripper rotation has stoppedh i ll )
Rod Handling System, RHS 140
To carousel with a tube
CLAIM: The carousel empty or not, tubes are supposed to be put back to the carousel.
Additional conditions:- Sensor B120 activated, PLC input X10-3/ON. (Arm in drill centre.)
- Sensor B178 deactivated, PLC input X16-1/OFF. (No tube in carousel outlet.)
- The rod grippers should be in hard grip during this movement as the PLC output X12-8 and X12-3 are OFF. This is also the normal condition of the grippers.
- RHS control lever S111 to position (a), input D551-CH2/ON.
When all the conditions are met, these two functions will take place in its order:• Solenoid valve Y310 will be activated by PLC output X15-4. The cylinder speed is
limited by restrictors 86 . (Carousel door opens.)• Solenoid valve Y301A will be activated by PLC output X12-4. The cylinder speed is
limited by restrictors 82 . (Tube transfer towards carousel starts.)
When the tube transfer arm has reached the position between the carousel and drill centre,sensor B119 will be activated, PLC input X10-2/ON. This results in:
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 235/368
• PLC output X12-4/OFF, Y301A deactivated. (Tube transfer stops.)•
PLC output X18-1/ON, Y311A activated. (This will rotate the rod grippersfrom facing the drill centre to facing the carousel.)
The gripper rotation sequence will continue for 3 seconds, after that:• PLC output 18-1/ON, Y311A activated. (Even though Y311A is activated,
but the gripper rotation has stopped mechanically.)• PLC output X12-4/ON, Y301A activated again. (Tube transfer towards
carousel continues.)
When the tube transfer arm have reached position carousel, sensor B118 will beactivated, PLC input X10-5/ON. This results in:
• PLC output X12-4/ON, Y301A activated. (Tube transfer towardscarousel stops mechanically.)
• PLC output X18-1/ON, Y311A activated. (Gripper rotation has stoppedmechanically.)
• PLC output X15-4/OFF, Y310 activated. (Carousel door closes.)SEQUENCE COMPLETE
Rod Handling System, RHS 140
To drill centre without a tube
CLAIM: The carousel could be empty or not, the grippers are in hard grip state in carousel.This is the case when drilling has been done, tubes are being pulled out and need to
be picked up from the drill centre.Loose grip is needed first when the grippers have been moved into the drill centre, becauseonly loose grip can allow the breakout table to take place and then allow the upper tube torotate out of the lower tube/drill bit which is being held in the lower breakout table. Loosegrip can be achieved by pulling the lever to the neutral position. Manual switching is neededhere since the lever is latched in this position.
Once the upper rod has been unthreaded, hard grip needs to be activated in order to allow therotation unit to be unthreaded. Hard grip can be achieved by pulling the lever backwards tothe “arm to drill centre” position, thus breaking the conditions for loose grip.
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 236/368
Rod Handling System, RHS 140
Additional conditions:- Sensor B118 activated, PLC input X10-5/ON. (Arm in carousel.) - RHS control lever S111 top button pushed, input D551-CH6/ON. The rod grippers
should be in open grip during this movement.- RHS control lever S111 to position (b), input D551-CH3/ON.
When all the conditions are met, this function will take place:• Solenoid valve Y310 will be deactivated by PLC output X15-4. (Carousel door isclosed.)
• Solenoid valve Y300 will be activated by PLC output X12-3. (Rod grippers are open.)• Solenoid valve Y301B will be activated by PLC output X12-5. The cylinder speed is
limited by restrictors 82 . (Arm transfer towards dill centre starts.)
When the tube transfer arm has reached the position between the carousel and drill centre,sensor B119 will be activated, PLC input X10-2/ON. This results in:
• PLC output X12-5/OFF, Y301B deactivated. (Arm transfer towards dill centrestops.)
• PLC output X16-12/ON, Y311B activated. (This will rotate the rod grippersfrom facing the carousel to facing the drill centre.)
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 237/368
The gripper rotation sequence will continue for 3 seconds, after that:•
PLC output X16-12/ON, Y311B activated. (Even though Y311B isactivated, but the gripper rotation has stopped mechanically.)• PLC output X12-5/ON, Y301B activated again. (Arm transfer towards drill
centre continues.)
When the tube transfer arm have reached position drill centre, sensor B120 willbe activated, PLC input X10-3/ON. This results in:
• PLC output X12-5/ON, Y301B activated. (Arm transfer towards drillcentre stops mechanically.)
• PLC output X16-12/ON, Y311B activated. (Gripper rotation has stoppedmechanically.)
SEQUENCE COMPLETE
Carousel rotationAdditional conditions:• The rod gipper arms must be in drill centre position or in the middle position, sensor
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 238/368
Rod Handling System, RHS 140
Drill steel supports & suction hoodConditions for these functions:• The Drilling/Tramming switch S130 must be in drilling position
o Drill steel supports, upper and lower – L8 30 The drill steel supports are controlled by switches S119 (upper) and S187 (lower), which
operates solenoid valves Y361A-B and Y350A-B respectively. The cylinder speed islimited by restrictors 91 and 92 .o Drill steel support, upper and lower – L7 40CRBoth the upper and lower drill steel supports are controlled by one switch S187 , whichoperates solenoid valves Y361A-B . The cylinder speed is limited by restrictor 91 .o Suction hoodThe suction hood is controlled by switch S167 , which operates solenoid valve Y357 . Thehydraulic pressure downwards is limited by pressure reducing valve 94 set to 40 bar, andthe cylinder speed is limited by restrictor 93 .
Breakout table and rock drill lockConditions for these functions:• The Drilling/Tramming switch S130 must be in drilling position
o Breakout wrench, clockwise and anti-clockwise rotation
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 239/368
The Breakout wrench is controlled by switch S258 , which opens solenoid valves Y352A-
B respectively. The cylinder speed is limited by restrictors 87 .o Breakout table, upper and lowerThe breakout table is controlled by switch S260 (upper) and S259 (lower), which operatessolenoid valves Y356A-B and Y354A-B respectively. The pressure to the upper breakouttable cylinder limited by pressure reducing valve 88 , and the pressure to the lowerbreakout table cylinder is limited by pressure reducing valve 89 .o Rock drill lock rotation – L7 40CR onlyThe rock drill lock is controlled by switch S257 , which opens solenoid valve Y359 . Thehydraulic pressure to the cylinder is limited by pressure reducing valve 98 set to 50 bar.
Service winch (Option)The service winch is a pure hydraulic function that works aside of the PLC. Solenoid valveY208 controls the moving direction of the winch, and it is activated by a lever that sits on thelower drill steel support.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 240/368
RHS 140 – L740
CR, L830
Input / SignalSwitch S130 in Drilling pos.
Operator in chair switch B379
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 241/368
1
RHS 140 – L740
CR, L830
Input / SignalS130/1 - D552, CH 1/ON
B379 - D550, CH 1/ON
S111 - D551, CH 2/3/4/5/6/ON
X10-5 B118
X10-2 B119
X10-3 B120X15-2 B182
X15-1 B183
Output on indicator card
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 242/368
2
Output on indicator cardX11-13 Y310
X17-1 Y301A/B
X11-14 Y311A/B
X13-11 Y303A/BX12-3 Y300
X12-8 Y306
1 B118
Page 33
L830 , L7 40CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 243/368
3
Y3101
Page 42 Tube transfer from carousel 1
B1193
Y301B
2 3 Off for 3 seconds when B119 is activated.Page 41
L830 , L7 40CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 244/368
4
Y311B
3 On when B119 is activated.
Tube transfer from carousel 2
Page 31
Page 42
B1193
Y301B
2 3 Off for 3 seconds when B119 is activated.Page 41
L830 , L7 40CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 245/368
5
Y311B
3 On when B119 is activated.
Tube transfer from carousel 2
Page 31
Page 42
Y301B
4 3 seconds later.Page 41
L830 , L7 40CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 246/368
6
B1205
Page 31Tube transfer from carousel 3
200 bar
u m p
1 )
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 247/368
7
Y310
Y311BY301B
R H S ( f r o m
p u
B182 2
Y303A 1 2 Rotation stops for 1 second.
Page 41
L830 , L7 40CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 248/368
8
Page 32 Carousel rotation CCW
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 249/368
200 bar
u m p
1 )
Y306
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 250/368
10
R H S ( f r o m
pY300
Extractor unit (Option)
Extractor unit (Option)The extractor function of the rock-drill consists of a hydraulic piston in the front part of therock-drill and a logic valve for the activation of it, the unit is also known as the back hammer.The hydraulic power is supplied from Pump 1.
The extractor unit is used when the rock conditions vary a lot and there is a large risk of jamming. The function of the extractor unit is to provide reverse percussion to the shankadapter and thus the drill string and drill bit. The shank adapter for rock-drills equipped withan extractor unit has a special flange that receives the reverse percussion force. Since theshank adapter is pressed into the rock-drill by the feed force during normal drilling, it workswithout the flange meeting the extractor piston.
The extractor piston lifts the shank-adapter to enable the impact piston to reach it whenfeeding backwards in a jam situation (see picture below).
extractorpiston
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 251/368
Activating the extractorDuring normal drilling, with a damper pressure above 50 bar, logic-L closes the extractorreturn connection and the system is closed. The main reason is to minimize oil consumptionand heat.
In case of a sudden loss of damper pressure e g drilling into weak formations or cavity
impact pistonshankadapter
Extractor unit (Option)
When feeding backwards, the damper pressureis below the minimum limit to allow impact,set by the DPC-I system. To make it possibleto activate impact when using the extractor itis necessary to override the DPC-I system.This is done by push-button S451 , whichactivates solenoid valve Y176 , which by-passes logic valves I and J . Consequently,impact can be activated at any damperpressure.
The oil flow to the extractor unit is limited byflow regulator 9 to correspond to a pressure of
22 bar with unloaded shank adapter and logic-L not activated. The pressure can be read ongauge outlet 8 on the service panel.
Pump pressure when using the extractorIt should be noticed that only low hammer/pump pressure is available when using back
S451
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 252/368
y p p p ghammer function. Logic valve C gets activated by reverse feed pilot pressure if high impact isactivated (see figure below left); and by pump pressure if low impact is activated (see figurebelow right), this prevents activation of logic-E . Without logic-E being activated, the pumppressure line going through logic-B will only lead oil to pressure relief valve 47e for pump 1pressure control.
TED-Extractor unit for COPROD (Option)
TED-Extractor unit for COPROD (Option)
The Rock drill can be equipped with a separate, air-powered extractor unit. The function ofthe extractor unit is to generate and transmit reverse percussion into the housing and therebyto the drill string and bit.The extractor unit, which is fitted in front of the rock drill, is powered by the flushing air.
L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 253/368
Water mist system (Option)
Water mist system (Option)Water mist can only be activated with reduced flushing air.
Water-mist system 225 LitresThe 225 litre water-mist system is a pressurized system. The water is injected into the
flushing air after it has been pressurized by the compressed air.
The system consists of:1. Tank2. Safety valve3. Drain valve4. Blow down valve5. Isolation valve6. Filter7. Needle valve8. Solenoid valves9. Check valves
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 254/368
The system is controlled by switch S448 as follows:• OFF – None of the solenoid valves Y112A-B are activated.• AUTO – Solenoid valve Y112A is activated. The amount of water
injected is limited by the needle valve 7.• MANUAL – Both of solenoid valves Y112A-B are activated. The
amount of water injected is limited by the isolation valve 5.
The water-mist system is primarily used for hole stabilization and dustcontrol by adding water into the flush air. Generally a small amount ofwater is used in order to make the drill dust moist and bind into largerparticles, for dust control, or to bind to the hole wall, for holestabilization. In this case switch S448 should be in position AUTO (b).The amount of injected water should be adjusted by the needle valve tomatch the dust characteristics. Different settings may be necessary on
different sites and different applications
a
b
c
a
b c
d
Water mist system (Option)
Water-mist system 400 LitresThe 400 litre water-mist system is a non-pressurized system. Thewater is pumped into the flushing air circuit by a pneumaticpiston pump.
The system consists of:1. Tank2. Pneumatic piston pump3. Solenoid valves4. Drain valve5. Isolation valve6. Filter7. Needle valve
8. Check valves
The system is controlled by switch S448 as follows:• OFF – None of the solenoid valves Y112A-C are activated. • AUTO – Solenoid valve Y112A is activated. Y112A
activates the pump. The amount of air to power the pump islimited by the needle valve 7.
• Y112A-B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 255/368
MANUAL – All of the solenoid valves areactivated. The amount of air to power the pump is limited bythe isolation valve 5.
• BLOW OFF – Double push on S448 forwards to blow out allthe water remaining in the system so the hose does notfreeze.
ECG, thread lubrication with oil (Option)
ECG, thread lubrication with oil (Option)
FunctionThe ECG pump Y107 starts pumping as soon as Flushing air is turned ON. The ECG pump isan electrical piston pump, controlled by the PLC output X11-16 which sends out pulses to the
pump. ECG injects a small amount of lubricating oil into the flushing air. The oil creeps alongthe walls of the flushing hole and out into the threaded joints. Atlas Copco recommends theuse of COP OIL for all ECG and ECL lubrication.
Conditions for the ECG function:
• Switch S130 in drilling position => D552-CH1/ON• Sensor B118 activated, RHS arm in carousel =>PLC input X10-5/ON• Compressor load switch S180 must be on => D552-CH9/ON• Impact switch S446A or S446B must be activated, to obtain air flushing => D550-
CH9/10/ONResult in:• PLC output X11-16/ON => Y107 activated
Adjusting• Ti l l h f h l i h
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 256/368
• Time pulse – length of the pulse, i.e. thesignal time.
• Pulses/minute – how many pulses there isper minute
Thread lubrication with grease brushes (Option)
Thread lubrication with grease brushes (Option)
FunctionLubrication of the drill steel threads is done by two brushes (A) mounted on the lower RHScarousel bracket.The grease is supplied by a pump placed in the front of the wagon frame. The pump ispowered by compressed air from the rig compressor and controlled through solenoid valveY552 .Activation of Y552 can be done either automatically or manually and is controlled by theswitch S449 on the drilling control panel.
A
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 257/368
Conditions for the automatic function:
• Switch S130 in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON• Brush greasing switch S449 in automatic mode, position (b) => D554-CH10/ON• RHS control lever S111 in arm to drill centre position => D551-CH3/ON
Result in:• PLC output X17-9/ON => Y552 activated for 2 seconds
When S449 is put in manual mode, no input from S111 is needed to cause the activation ofY552.
Thread lubrication with grease brushes (Option)
Operating• In normal operation, the system works in automatic mode. The grease pump is activated
when the rod handling lever S111 is in position to transfer a rod to drill centre. The resultis that each time a rod is removed from the carousel, a quantity of lubricant is pumped intothe brushes that the threads of the drill rod pass through.
•
If there is a need to additional grease, the system can be run manually. In this case thegrease pump is activated as long as switch S449 is kept in position (a).• If there is no need for thread greasing the system can be turned off by putting switch S449
in position (c).
a
b
c
ab c
d
L7
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 258/368
The maximum pressure to the pump is adjusted to 7 bars by the pressure regulator 21 which isdisplayed by the pressure gauge 22. The system can be switched off by blocking the airsupply with ball cock valve 8 or by the electrical switch in the cabin.
We recommend the use of “Atlas Copco Secoroc thread lubricant A” for the lubrication ofdrill steel threads.
Spray greasing system (Option)
Spray greasing system (Option)
FunctionLubrication of the drill steel threads is doneby an air spray and a grease injectormounted on the lower RHS carouselbracket.The grease is injected by a pump placed inthe front of the wagon frame. The greasepump is powered by compressed air fromthe rig compressor and controlled throughsolenoid valve Y552A . Compressed air isalso used for the spraying, and it’s
controlled by solenoid valve Y552B . Whenfunctioning, solenoid valve Y552B for airspray is set to start first before solenoidvalve Y552A for grease pump. The air thensprays grease onto the thread. Whenshutting off the function, Y552A is set to beturned off first before Y552B.Activation of Y552 is done manually and iscontrolled by the switch S449 on the
L8 , L7 CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 259/368
controlled by the switch S449 on thedrilling control panel.
Conditions for the function:
• Switch S130 in drilling position => D552-CH1/ON• Compressor load switch S180 must be on => D552-CH9/ON • Spray greasing switch S449 activated, position (a) => D554-CH9/ONResult in:o X11-10/ON => Y552B activated for 1 secondo X15-8/ON => Y552A activated after 400 ms, then activated for 200 ms
The maximum pressure to the pump is adjusted to 7 bars by the pressure regulator 21 which isdisplayed by the pressure gauge 22. The system can be switched off by blocking the airsupply with ball cock valve 8 or by the electrical switch in the cabin.
Laser sensor (Option)
Laser sensor (Option)Laser sensor B316 on the rock drill cradle sends in data signals via CPU3 which areprocessed by the display for showing the correct hole length/hole depth information as perpreview.
The laser sensor is most often used in undulating terrain to maintain as level a hole bottom aspossible for blasting.
10m
Hole bottom
4m
Drill bit position
Laser sensor position
Laser level
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 260/368
Hole bottom
Ex:A rotary laser is placed at the highest point in the area. From here, the depth to hole bottom ismeasured (in this case 10 m). When the rotary laser hits the sensor B316 on the rock drillcradle, the length between the sensor and drill bit (in this case 4 m) is automatically shown onthe display, irrespective of how many metres that has been drilled. This is done every time the
hole depth is reset. In this case, we know that there are 6 metres left to hole bottom (10-4=6m).
If it takes one meter for B316 to be hit by the rotary sensor in the above example, thefollowing describes the transaction which will take place on the display.
Q
I
JD
B
CA
Y101AY101B
L
Y176
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 261/368
1
low
Y101AY101B
Y112A
Water/air mixture
Watertank
Y116
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 262/368
2
M a
i n a
i r f l o w
Adjustment/calibration
Adjustment/calibration
Calibrating of positioning instruments
Calibration of laser sensorThe manually measured length value between thedrill bit and laser sensor when the drill bit isapplied to the ground. This value is entered in themenu for calibrating the laser sensor.
Calibration of aiming deviceThe aiming device is set in straight-forwardposition in the track’s extension. By selecting the
button for the aim device in the menusensor/calibration and pressing enter the functionis calibrated.
Calibration of length sensorRun the rock drill cradle to the feeder’s uppermechanical stop. Mark the button for cradleposition in the sensor/calibration menu and pressEnter to calibrate the function.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 263/368
Calibration of angle sensor on feed beamPosition the feeder in the vertical position. Markthe button for feed swing and/or feed dump in thesensor/calibration menu and press Enter tocalibrate the function.
Calibration of boom joint sensorPosition the boom in the straight ahead position.Mark the button for boom swing angle in thesensor/calibration menu and press Enter tocalibrate the function.
Adjustment/calibration
Adjustable drilling parameters
RPCF
High impact pressure
High feed pressure
RPCF system(only in L7 )40
Rotation speed
Low impact pressure
Low feed pressure
Threading pressure
Unthreading pressure
ROC L7 , L7 CR with Bosal cabin
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 264/368
Not used
High feed pressure
Not used
Low feed pressure
Threading pressure
ROC L8 30 with Bosal cabin
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)
PLC-PROGRAMME EXPLANATION
DRILLRIG TYPE : ROC L7 40 PLC TYPE : IFM CR0200/CR0020
PLC PART NUMBER : 3176 0001 50/3176 0001 55INDEX
INDEX .........................................................................................................................................................................................1 1. GENERAL FUNCTIONS ....................................................................................................................................................2
1.1 Power supply.....................................................................................................................................................................2 1.2 Engine cranking.................................................................................................................................................................2 1.3 Start Conditions for diesel engine....................................................................................................................................2 1.4 Pump 4 unload..................................................................................................................................................................2 1.5 Hydraulic oil pre-heating..................................................................................................................................................2 1.6 Indication for hydraulic jack (option)..............................................................................................................................2 1.7 Diesel filler pump stop ..................................................................................................................................................... 2
2. TRAMMING FUNCTIONS .................................................................................................................................................3 2.1 Tramming low speed.........................................................................................................................................................3 2.2 Tramming high speed........................................................................................................................................................3
3. DRILLING FUNCTIONS ....................................................................................................................................................3 3.1 Flushing, reduced..............................................................................................................................................................3 3.2 Flushing, full.....................................................................................................................................................................3 3.3 Dust Collector, suction control .......................................................................................................................................3 3.4 ECL-pump.........................................................................................................................................................................4 3.5a ECG-pump (option)........................................................................................................................................................4 3.5b Thread lubrication with grease brushes, automatic mode (option)..............................................................................4 3.6a Anti-jamming activated by high rotation pressure.........................................................................................................4 3.6b Anti-jamming activated by flushing...............................................................................................................................5
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 265/368
3.7 Feed lever, logic direction when anti-jamming is active ................................................................................................5 3.8a Low percussion with function self-holding...................................................................................................................5 3.9a High percussion with function self-holding..................................................................................................................6 3.8/3.9b Deactivation of magnetic holding for drill lever ....................................................................................................6 3.10 Impact hour counter........................................................................................................................................................6 3.11 Automatic drill stop function.........................................................................................................................................7 3.12 Impact stroke...................................................................................................................................................................7 3.13 Water mist system (option) ............................................................................................................................................7
4. RAPID FEED STOP FUNCTIONS ...................................................................................................................................8 4.1 Rapid feed stop, forward ..................................................................................................................................................8 4.2 Rapid feed stop, backwards, at break out position..........................................................................................................8 4.3 Rapid feed stop, backwards, at magazine level................................................................................................................8 4.4 Rapid feed stop, backwards, max .....................................................................................................................................8
5. ROD HANDLING FUNCTIONS ........................................................................................................................................9 5.1 Open Gripper.....................................................................................................................................................................9 5.2 Guide grip..........................................................................................................................................................................9 5.3 Hard grip............................................................................................................................................................................9 5 4 RHS t d d ill t 9
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
1. GENERAL FUNCTIONS1.1 Power supply
S139/Ignition ON K11Fuse F13-F23/ON + 24V +24VX1/100 - ground connection
• When ignition key S139 is in position I, ignition ON, relay K11 is activated to allow power supply tofuse F13, F15-F22. Fuse F14 and F23 are powered directly aside from the K11 relay.
1.2 Engine crankingS130/Tramming pos. D552-CH2/3/ON X11-13/ON Y121A
X17-1/ON Y121BS180/Compressor load D552-CH9/OFF X18-8/OFF Y210 OFFE-stops S132A, S132Bnot activated X10-8/ONS139/Engine start D550-CH3/ON X11-4/ON K5A
1.3 Start Conditions for diesel engineB366/Compressor temp. X16-7 (< ~17.5mA)B362/Hydraulic oil temp. X16-5 (< ~15mA)B143/Hydraulic oil level X11-8/ON X11-3/ON K200
1.4 Pump 4 unloadS130/Tramming pos. D552-CH2/3/ON X11-13/ON Y121AS139/Engine start D550-CH3/ON X17-1/OFF Y121B OFF
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 266/368
S139/Ignition D550-CH4/ON X17-1/ON Y121B
• When the ignition switch S139 is release from starting position and re-springed back to the ignitionposition, the output X17-1 will be ON until the diesel motor has reached a revolution of 1000 rpm.
1.5 Hydraulic oil pre-heating
S130/Pre-heating position D552-CH4/ON X11-13/ON Y121AX17-1/ON Y121BX11-12/ON Y120A
Y120BY120C
1.6 Indication for hydraulic jack (option)B184/Dis-ACTIVE X11-1/OFF Indication in display
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
2. TRAMMING FUNCTIONS2.1 Tramming low speed
S130/Tramming pos. low D552-CH2/ON X11-13/ON Y121AX17-1/ON Y121BX11-1/ON Y169
S121/Chair in position D550-CH2/ONB184/Active (option) X11-1/ONS174/S175/Activated D553/CH13 or 14/ON X10-9/10/ON Y206
X10-11/12/ON Y207
2.2 Tramming high speedS130/Tramming pos. high D552-CH3/ON X11-13/ON Y121A
X17-1/ON Y121BX11-1/ON Y169X11-14/ON Y122
S121/Chair in position D550-CH2/ONB184/Active (option) X11-1/ONS174/S175/Activated D553/CH13 or 14/ON X10-9/10/ON Y206
X10-11/12/ON Y207
3. DRILLING FUNCTIONS3.1 Flushing, reduced
S130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ON
l d ( b d d )
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 267/368
S180/Compressor load (not PLC based condition)S100/Flush air pos. reduced D551-CH1/OFFS446A/Flushing pos. D550-CH9/ON X17-14/ON Y116
• To start flushing, press the impact switch S446A for shorter than 0.5 sec. To start low impact, pressswitch S446A for longer than 0.5 sec.
3.2 Flushing, fullS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S100/Flush air pos. full D551-CH1/ONS446A/Flushing pos. D550-CH9/ON X17-14/ON Y116
X17-13/ON Y115
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.4 ECL-pumpS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S446/Low or High Imp. D550-CH9/10/ON X17-9/ON Y106
• The ECL-pump Y106 works for an extended time after impact switch S446 have been shut-off afterdrilling, the time delay can be adjusted via the HEC3 display.
• To start low impact, press the impact switch S446A for longer than 0.5 sec.
3.5a ECG-pump (option)S130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S446/Flushing pos. D550-CH9/10/ON X11-16/ON Y107
• To start flushing and DCT, press the impact switch S446A for shorter than 0.5 sec. To start low/highimpact, press the impact switch S446A for longer than 0.5 sec.
3.5b Thread lubrication with grease brushes, automatic mode (option)S130/Drilling pos. D552-CH1/ONS180/Compressor load (not PLC based condition)S449/Automatic pos. D554-CH10/ONS111/Arm to drill centre D551-CH3/ON X15-8/ON Y552
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 268/368
3.6a Anti-jamming activated by high rotation pressureS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS446/Low or High Imp. D550-CH9/10/ONB262/Not activated X16-16/OFFB134/ACTIVE X11-6/ON X11-11/ON Y109
X11-9/OFF Y101A OFFB134/De-activated X11-6/OFF X11-11/OFF Y109 OFF
X11-9/ON Y101AX13-12/ON Y101BX11-15/OFF Y101C OFF
……4 sec….. X13-12/OFF Y101B OFFX11-15/ON Y101C
• Input X11-6 must be ON for a minimum of 0.8 sec in order to result in output Y11-11.
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.6b Anti-jamming activated by flushingS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S100/Full flush air pos. D551-CH1/ONS446/Flush air/impact pos. D550-CH9/10/ONB262/Not activated X16-16/OFFB142/Active X11-7/ON X11-11/ON Y109
X11-9/OFF Y101A OFFB142/De-activated X11-7/OFF X11-11/OFF Y109 OFF
X11-9/ON Y101AX13-12/ON Y101BX11-15/OFF Y101C OFF
……4 sec….. X13-12/OFF Y101B OFFX11-15/ON Y101C
• The flow switch is only functioning during full flushing. The minimum activating time is set by PLCinternally to 0.8 sec.
• Y11-11 will remain active for a minimum of 2 sec or until the pressure drop/air flow is back tonormal.
• When anti-jamming has been de-activated low feed and low impact pressure will be activated for 4sec. before going to high feed and high impact pressure.
• When feed backwards is automatically activated during anti-jamming output X11-9 will be OFF. Thisdeactivates Y101A, which means full pump pressure is available for feeding backwards.
3 7 Feed lever logic direction when anti jamming is active
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 269/368
3.7 Feed lever, logic direction when anti-jamming is activeS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB134/ACTIVE X11-6/ON X11-11/ON Y109B262/ACTIVE X16-16/ON X11-11/OFF Y169 OFF
• Pulling the drill lever to feed backwards position activates B262. This will block the anti jammingoutput X11-11 to allow logic function of the drill lever.
3.8a Low percussion with function self-holdingMagnetic holding on rotation anti-clockwise and feeding forwards can only be achieved when the controllever is being pulled to the end position, pulling the lever only half way and then release would result in leverspringed back to the neutral position.
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)
S452/R id f d d ff D550 CH11/OFF D550 CH7/ON Y179A
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.9a High percussion with function self-holdingS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S452/Rapid feed mode off D550-CH11/OFF D550-CH7/ON Y179A
D550-CH8/ON Y179BD550-CH15/ON H452
S446A/Low impact D550-CH9/ON X11-9/ON Y101A
X13-12/ON Y101BX17-13/ON Y115*X17-14/ON Y116
D550-CH16/ON H446⇓ ⇓ ⇓ ⇓
S446B/High impact D550-CH10/ON X13-12/OFF Y101B OFFX11-15/ON Y101CX17-13/ON Y115*
X17-14/ON Y116D550-CH16/ON H446
• To shift to high impact from low impact, press S446B for longer than 0.5 sec, pressing the button oncemore or shorter than 0.5 sec would deactivate impact/flushing and the lever returns to the neutralposition.
• When changing back to low impact, press the low impact pressure switch S446A for longer than 0.5sec, otherwise the impact will be shut off.
• When switch S446B is activated, valve Y101C for high feed pressure is activated, valve Y101B forlow impact pressure is deactivated.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 270/368
p p• Diode H446 gives stable signal when drilling with high impact.• When performing percussion release or starting directly on high impact, impact is activated as long as
switch S446B is pressed.• Valve Y115 is only activated when full flushing air is chosen by switch S100.
3.8/3.9b Deactivation of magnetic holding for drill leverS453/Magnets off drill lever D550-CH12/ONORS452/Rapid feed mode D550-CH11/ON D550-CH7/OFF
D550-CH8/OFF
3.10 Impact hour counterS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact pos. D550-CH9/10/ON parameter in software
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.11 Automatic drill stop functionparameter in software/Active X11-9/OFF Y101A OFF
X17-13/OFF Y115 OFFX17-14/OFF Y116 OFFD550-CH7/OFFD550-CH8/OFFD550-CH15/OFF X12-2/ON Y178
• Engine rpm will be lowered to 1500 rpm.• The drill lever is automatically shifted to rapid feed/threading mode when the desired drill
depth/length is reached.
3.12 Impact strokeS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFF
Short stroke S400/Upper pos D553-CH7/ON X17-15/OFF Y175 OFFShort stroke S400/Lower pos D553-CH7/OFF
S446A/Low impact D550-CH9/ON X17-15/OFF Y175 OFFLong stroke S400/Lower pos D553-CH7/OFF
S446B/High impact D553-CH10/ON X17-15/ON Y175
3.13 Water mist system (option)S130/Drilling pos. D552-CH1/ONS180/Compressor load (not PLC based condition)S446A/Reduced flush air D550-CH9/ON
Automatic S448/Middle pos D554-CH4/ON X17-11/ON Y112AX17-10/ON Y112C*
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 271/368
Manual S448/Upper pos D554-CH3/ON X17-11/ON Y112AX17-12/ON Y112BX17-10/ON Y112C*
• Valve Y112C is activated if the 400 litre water-mist system is used.
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
4. RAPID FEED STOP FUNCTIONS4.1 Rapid feed stop, forward
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
software stop X17-2/ON Y150
4.2 Rapid feed stop, backwards, at break out positionS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
S113/Take up rod string D551-CH9/ONsoftware stop X16-10/ON *Y149
*Y149 only activated for 2 seconds.
4.3 Rapid feed stop, backwards, at magazine levelS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
S113/Take up rod string D551-CH9/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 272/368
software stop X16-10/ON *Y149*Y149 only activated for 2 seconds.
4.4 Rapid feed stop, backwards, maxS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
software stop X16-10/ON Y149
• The stop signals come from HEC-3 program,and all the stop distances can be set in thedisplay. The signal is then sent to the PLC for 4.1
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5. ROD HANDLING FUNCTIONS5.1 Open Gripper
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONS111/Top button pushed D550-CH6/ON X12-3/ON Y300
5.2 Guide gripS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONS111/RHS lever in neutral D551-CH2/3/4/5/6/OFF
..….0.5 sec…. X12-8/ON Y306• The activation of Y306 is delayed 0.5 sec by the PLC.
5.3 Hard gripS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFF
• Hard grip is the normal condition. No active inputs or outputs are required.
5.4 RHS, arm towards drill-centre
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 273/368
B118/RHS-arm in carousel X10-5/ONS111/Arm to drill centre D551-CH3/ON
Arm movement starts X12-5/ON Y301B⇓
Arm in drill centre B120/ACTIVE X10-3/ONArm in carousel stops mechanically X12-5/ON Y301B
⇓ Sequence complete
• The output X12-5 remains activated until the sequence is completed although the function is stoppedmechanically.
5.5 RHS, arm towards carouselS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFF
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5.6 RHS, carousel rotation, clockwiseS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB118/RHS-arm in carousel X10-5/ONS111/Push the top button D551-CH6/ONS111/Pos, to the left. D551-CH4/ON
Rotation starts B183/ACTIVE X13-1/ON X15-2/ON Y303A
⇓ B183/Dis-ACTIVE X13-1/OFFRotation stops B183/ACTIVE X13-1/ON X15-2/OFF Y303A OFF
⇓ Sequence complete
5.7 RHS, carousel rotation, anti-clockwiseS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFF
B379/Operator seat active D550-CH1/ONB118/RHS-arm in carousel X10-5/ONS111/Push the top button D551-CH6/ONS111/Pos, to the right. D551-CH5/ON
Rotation starts B182/ACTIVE X14-8/ON X15-1/ON Y303B⇓ B182/Dis-ACTIVE X14-8/OFF
Rotation stops B182/ACTIVE X14-8/ON X15-1/OFF Y303B OFF
⇓ Sequence complete
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 274/368
5.8 Sleeve retainer activationS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONS182/Sleeve retainer D551-CH13/ON X15-3/ON Y309
• Sleeve retainer activation is time delayed in PLC, to secure that the rod grippers are in drill centrebefore activation.
5.9 Sleeve retainer de-activationS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS182/Sleeve retainer D551-CH13/OFF X15-3/OFF Y309 OFF
2008-10-21 PLC Programme, ROC L7 40 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
6. MONITORING FUNCTIONS 6.1 Low hydraulic oil level, engine shut down
B143/Open contact X11-8/OFF X11-3/OFF K200 OFF
6.2 High hydraulic oil temperatureB362/sensor reached 90°C X16-5 X11-3/OFF K200 OFF
6.3 High compressor temperatureB366/sensor reached 120°C X16-7 X11-3/OFF K200 OFF
• For all the functions mentioned above, loss of X11-3 deactivates the start engine relay K200. WhenK200 is not activated, it is connected to the ground, thus shutting down the engine.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 275/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 276/368
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)
PLC-PROGRAMME EXPLANATIONDRILLRIG TYPE : ROC L7 40CRPLC TYPE : IFM CR0200/CR0020
PLC PART NUMBER : 3176 0001 50/3176 0001 55INDEX
INDEX .........................................................................................................................................................................................1 1. GENERAL FUNCTIONS ....................................................................................................................................................2
1.1 Power supply.....................................................................................................................................................................2 1.2 Engine cranking.................................................................................................................................................................2 1.3 Start Conditions for diesel engine....................................................................................................................................2 1.4 Pump 4 unload..................................................................................................................................................................2 1.5 Hydraulic oil pre-heating..................................................................................................................................................2 1.6 Indication for hydraulic jack (option)..............................................................................................................................2 1.7 Diesel filler pump stop ..................................................................................................................................................... 2
2. TRAMMING FUNCTIONS .................................................................................................................................................3 2.1 Tramming low speed.........................................................................................................................................................3 2.2 Tramming high speed........................................................................................................................................................3
3. DRILLING FUNCTIONS ....................................................................................................................................................3 3.1 Flushing, reduced..............................................................................................................................................................3 3.2 Flushing, full.....................................................................................................................................................................3 3.3 Dust Collector, suction control .......................................................................................................................................4 3.4 ECL-pump.........................................................................................................................................................................4 3.5 HECL-pump......................................................................................................................................................................4 3.6 Spray greasing activation (option) ...................................................................................................................................5 3.7a Anti-jamming activated by high rotation pressure.........................................................................................................5 3.7b Anti-jamming activated by flushing...............................................................................................................................5 3.8 Feed lever, logic direction when anti-jamming is active ................................................................................................6 3.9a Low percussion with function self-holding...................................................................................................................6
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 277/368
3.9a Low percussion with function self holding...................................................................................................................6 3.10a High percussion with function self-holding................................................................................................................7 3.9/3.10b Deactivation of magnetic holding for drill lever..................................................................................................7 3.11 Impact hour counter........................................................................................................................................................7 3.12 Automatic drill stop function.........................................................................................................................................8 3.13 Impact stroke...................................................................................................................................................................8 3.14 Water mist system (option) ............................................................................................................................................8
4. RAPID FEED/FEED STOP F UNCTIONS ......................................................................................................................9 4.1 Feed stop/Impact stop, forward........................................................................................................................................9 4.2 Rapid feed stop, forward ..................................................................................................................................................9 4.3 Rapid feed stop, backwards, at break out position..........................................................................................................9 4.4 Rapid feed stop, backwards, at magazine level................................................................................................................9 4.5 Rapid feed stop, backwards, max .....................................................................................................................................9
5. ROD HANDLING FUNCTIONS ......................................................................................................................................10 5.1 Open Gripper...................................................................................................................................................................10 5.2 Guide grip........................................................................................................................................................................10
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 278/368
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
2. TRAMMING FUNCTIONS2.1 Tramming low speed
S130/Tramming pos. low D552-CH2/ON X11-13/ON Y121AX17-1/ON Y121BX11-1/ON Y169
S121/Chair in position D550-CH2/ONB184/Active (option) X11-1/ONS174/S175/Activated D553/CH13 or 14/ON X10-9/10/ON Y206
X10-11/12/ON Y207
2.2 Tramming high speedS130/Tramming pos. high D552-CH3/ON X11-13/ON Y121A
X17-1/ON Y121BX11-1/ON Y169X11-14/ON Y122
S121/Chair in position D550-CH2/ON
B184/Active (option) X11-1/ONS174/S175/Activated D553/CH13 or 14/ON X10-9/10/ON Y206
X10-11/12/ON Y207
3. DRILLING FUNCTIONS3.1 Flushing, reduced
S130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 279/368
p ( )S100/Flush air pos. reduced D551-CH1/OFFS446A/Flushing pos. D550-CH9/ON X17-14/ON Y116
• To start flushing, press the impact switch S446A for shorter than 0.5 sec. To start low impact, pressswitch S446A for longer than 0.5 sec.
3.2 Flushing, fullS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S100/Flush air pos. full D551-CH1/ONS446A/Flushing pos. D550-CH9/ON X17-14/ON Y116
X17-13/ON Y115
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.3 Dust Collector, suction controlS130/Drilling pos. D552-CH1/ON X18-2/ON Y250B118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S181/Suction pos. D551-CH12/ONS446/Flushing pos. D550-CH9/10/ON X18-7/ON Y253
• To start flushing and DCT, press the impact switch S446A for shorter than 0.5 sec. To start low
impact, press the impact switch S446A for longer than 0.5 sec.• When Impact is shut OFF there is a 4 seconds delay before X18-7 goes OFF and suction stops.
3.4 ECL-pumpS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S446/Low or High Imp. D550-CH9/10/ON X17-9/ON Y106
• The ECL-pump Y106 works for an extended time after impact switch S446 have been shut-off afterdrilling, the time delay can be adjusted via the HEC3 display.
• To start low impact, press the impact switch S446A for longer than 0.5 sec.
3.5 HECL-pumpS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S446/Flushing pos. D550-CH9/10/ON X11-16/ON Y165
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 280/368
• The HECL-pump Y165 works for an extended time after impact switch S446 have been shut-offafter drilling, the time delay can be adjusted via the HEC3 display.
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.6 Spray greasing activation (option)S130/Drilling pos. D552-CH1/ONS180/Compressor load (not PLC based condition)S449/Manual pos. D554-CH10/ON X15-8/ON Y552A
X16-11/ON Y552B
3.7a Anti-jamming activated by high rotation pressureS130/Drilling pos. D552-CH1/ON
B118/RHS-arm in carousel X10-5/ONS446/Low or High Imp. D550-CH9/10/ONB262/Not activated X16-16/OFFB134/ACTIVE X11-6/ON X11-11/ON Y109
X11-9/OFF Y101A OFFB134/De-activated X11-6/OFF X11-11/OFF Y109 OFF
X11-9/ON Y101AX13-12/ON Y101B
X11-15/OFF Y101C OFF……4 sec….. X13-12/OFF Y101B OFFX11-15/ON Y101C
• Input X11-6 must be ON for a minimum of 0.8 sec in order to result in output Y11-11.• Y11-11 will remain active for a minimum of 2 sec or until the rotation pressure drops below the
setting of sensor B134.• When anti-jamming has been de-activated low feed and low impact pressure will be activated for 4
sec. before going to high feed and high impact pressure.• When feed backwards is automatically activated during anti-jamming output X11-9 will be OFF.
This deactivates Y101A, which means full pump pressure is available for feeding backwards.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 281/368
3.7b Anti-jamming activated by flushingS130/Drilling pos. D552-CH1/ONB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S100/Full flush air pos. D551-CH1/ONS446/Flush air/impact pos. D550-CH9/10/ONB262/Not activated X16-16/OFFB142/Active X11-7/ON X11-11/ON Y109
X11-9/OFF Y101A OFFB142/De-activated X11-7/OFF X11-11/OFF Y109 OFF
X11-9/ON Y101AX13-12/ON Y101B
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.8 Feed lever, logic direction when anti-jamming is activeS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB134/ACTIVE X11-6/ON X11-11/ON Y109B262/ACTIVE X16-16/ON X11-11/OFF Y109 OFF
• Pulling the drill lever to feed backwards position activates B262. This will block the anti jammingoutput X11-11 to allow logic function of the drill lever.
3.9a Low percussion with function self-holdingMagnetic holding on rotation clockwise and feeding forwards can only be achieved when the control leveris being pulled to the end position, pulling the lever only half way and then release would result in leverspringed back to the neutral position.
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S452/Rapid feed mode off D550-CH11/OFF D550-CH7/ON Y179A
D550-CH8/ON Y179BD550-CH15/ON H452
S446A/Low impact D550-CH9/ON X11-9/ON Y101AX13-12/ON Y101BX17-13/ON Y115*X17-14/ON Y116
D550-CH16/ON H446
•
To activate impact, press S446A for longer than 0.5 sec, pressing the button once more for shorterthan 0.5 sec would deactivate impact/flushing and the lever returns to the neutral position.
• Diode H446 gives blinking signals when drilling with low impact.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 282/368
• Valve Y115 is only activated when full flushing air is chosen by switch S100.
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.10a High percussion with function self-holdingS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S452/Rapid feed mode off D550-CH11/OFF D550-CH7/ON Y179A
D550-CH8/ON Y179BD550-CH15/ON H452
S446A/Low impact D550-CH9/ON X11-9/ON Y101A
X13-12/ON Y101BX17-13/ON Y115*X17-14/ON Y116
D550-CH16/ON H446⇓ ⇓ ⇓ ⇓
S446B/High impact D550-CH10/ON X13-12/OFF Y101B OFFX11-15/ON Y101CX17-13/ON Y115*
X17-14/ON Y116D550-CH16/ON H446
• To shift to high impact from low impact, press S446B for longer than 0.5 sec, pressing the buttononce more or shorter than 0.5 sec would deactivate impact/flushing and the lever returns to theneutral position.
• When changing back to low impact, press the low impact pressure switch S446A for longer than 0.5sec, otherwise the impact will be shut off.
•
When switch S446B is activated, valve Y101C for high feed pressure is activated, valve Y101B forlow impact pressure is deactivated.• Diode H446 gives stable signal when drilling with high impact.
h d l h h h d l h d
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 283/368
• When starting directly with high impact, impact is activated as long as switch S446B is pressed.• Valve Y115 is only activated when full flushing air is chosen by switch S100.
3.9/3.10b Deactivation of magnetic holding for drill leverS453/Magnets off drill lever D550-CH12/ONORS452/Rapid feed mode D550-CH11/ON D550-CH7/OFF
D550-CH8/OFF
3.11 Impact hour counterS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact pos. D550-CH9/10/ON parameter in software
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
3.12 Automatic drill stop functionparameter in software/Active X11-9/OFF Y101A OFFX17-13/OFF Y115 OFFX17-14/OFF Y116 OFFD550-CH7/OFFD550-CH8/OFFD550-CH15/OFF X12-2/ON Y178
• Engine rpm will be lowered to 1500 rpm.
• The drill lever is automatically shifted to rapid feed/threading mode when the desired drilldepth/length is reached.
3.13 Impact strokeS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFF
Short stroke S400/Upper pos D553-CH7/ON X17-15/OFF Y175 OFFShort stroke S400/Lower pos D553-CH7/OFF
S446A/Low impact D550-CH9/ON X17-15/OFF Y175 OFFLong stroke S400/Lower pos D553-CH7/OFF
S446B/High impact D553-CH10/ON X17-15/ON Y175
3.14 Water mist system (option)S130/Drilling pos. D552-CH1/ONS180/Compressor load (not PLC based condition)S446A/Reduced flush air D550-CH9/ON
Automatic S448/Middle pos D554-CH4/ON X17-11/ON Y112AX17-10/ON Y112C*
Manual S448/Upper pos D554-CH3/ON X17-11/ON Y112AX17 12/ON Y112B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 284/368
X17-12/ON Y112BX17-10/ON Y112C*
• Valve Y112C is activated if the 400 litre water-mist system is used.
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
4. RAPID FEED/FEED STOP FUNCTIONS4.1 Feed stop/Impact stop, forward
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Feed mode D550-CH11/OFF X12-2/ON K178
D550-CH7/OND550-CH8/OND550-CH15/ON
software stop X17-2/ON Y150
4.2 Rapid feed stop, forwardS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
software stop X17-2/ON Y150
4.3 Rapid feed stop, backwards, at break out positionS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
S113/Take up rod string D551-CH9/ON
software stop X16-10/ON *Y149*Y149 only activated for 2 seconds.
4 4 R id f d b k d i l l
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 285/368
4.4 Rapid feed stop, backwards, at magazine levelS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFF
D550-CH15/OFFS113/Take up rod string D551-CH9/ON
software stop X16-10/ON *Y149*Y149 only activated for 2 seconds.
4.5 Rapid feed stop, backwards, maxS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFF
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5. ROD HANDLING FUNCTIONS5.1 Open Gripper
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONS111/Top button pushed D550-CH6/ON X12-3/ON Y300
5.2 Guide grip
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONS111/RHS lever in neutral D551-CH2/3/4/5/6/OFF
..….0.5 sec…. X12-8/ON Y306• The activation of Y306 is delayed 0.5 sec by the PLC.
5.3 Hard gripS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFF
• Hard grip is the normal condition. No active inputs or outputs are required. Exceptions are opengripper and Guide grip.
5.4 RHS, arm towards drill-centre with closed grippers (Tube in grippers)
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB118/RHS i l X10 5/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 286/368
B118/RHS-arm in carousel X10-5/ONS111/Arm to drill centre D551-CH3/ON
Outlet hatch opens X15-4/ON Y310Arm movement starts X12-5/ON Y301B
⇓ Halfway sensor B119/ACTIVE X10-2/ONArm movement stops X12-5/OFF
Y301B OFFGripper rotation starts towards drill centre X16-12/ON Y311B
⇓ Timer delay 3 sec after B119 is activated…Gripper rotation stops mechanically X16-12/ON Y311BArm movement continues X12-5/ON Y301B
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5.5 RHS, arm towards drill-centre with open grippers S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB118/RHS-arm in carousel X10-5/ONS111/Arm to drill centre D551-CH3/ONS111/Push the top button D551-CH6/ON
Outlet hatch is closed X15-4/OFF Y310 OFF
Rod grippers open X12-3/ON Y300Arm movement starts X12-5/ON Y301B⇓
Half way sensor B119/ACTIVE X10-2/ONArm movement stops X12-5/OFF Y301B OFFGripper rot. starts towards drill centre X16-12/ON Y311B
⇓ Timer delay 3 sec after B119 is activated…
Gripper rot. stops mechanically X16-12/ON Y311BArm movement continues X12-5/ON Y301B⇓
Arm in drill centre B120/ACTIVE X10-3/ONArm movement stops mechanically X12-5/ON Y301BGripper rot. stopped mechanically X16-12/ON Y311B
⇓ Sequence complete
• The output X12-5 and X16-12 remain activated until the sequence is completed although thefunction is stopped mechanically.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 287/368
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5.6 RHS, arm towards carousel with closed gripper (Tube in grippers) S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB178/Dis-ACTIVE X16-1/OFFB120/RHS-arm in drill centre X10-3/ONS111/Arm to carousel pos. D551-CH2/ON
Outlet hatch opens X15-4/ON Y310Arm movement starts X12-4/ON Y301A
⇓ Halfway sensor B119/ACTIVE X10-2/ONArm movement stops X12-4/OFF Y301A OFFGripper rot. towards carousel starts X18-1/ON Y311A
⇓ Timer delay 3 sec after B119 is activated…Gripper rot. stops mechanically X18-1/ON Y311A
Arm movement continues X12-4/ON Y301A⇓ Magazine sensor B118/ACTIVE X10-5/ONArm movement stops mechanically X12-4/ON Y301AGripper rot. stopped mechanically X18-1/ON Y311AOutlet hatch is closed. X15-4/OFF Y310 OFF
⇓ Sequence complete
• The output X12-4 and X18-1 remain activated until the sequence is completed although the functionis stopped mechanically.
• Outlet hatch will remain opened until last condition is fulfilled (B118 activated).
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 288/368
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5.7 RHS, arm towards carousel with open gripper S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONS111/Push the top button. D551-CH6/ONS111/Arm to carousel pos. D551-CH2/ON
Outlet hatch is closed X15-4/OFF Y310 OFFOpen grippers X12-3/ON Y300Arm movement starts X12-4/ON Y301A
⇓ Halfway sensor. B119/ACTIVE X10-2/ONArm movement stops X12-4/OFF Y301A OFFGripper rot. towards carousel starts X18-1/ON Y311A
⇓ Timer delay 3 sec after B119 is activated…Gripper rot. stops mechanically X18-1/ON Y311AArm movement continues X12-4/ON Y301A
⇓ Arm in carousel B118/ACTIVE X10-5/ONArm in carousel stops mechanically X12-4/ON Y301AGripper rot. stopped mechanically X18-1/ON Y311A
⇓ Sequence complete
• The output X12-4 and X18-1 remain activated until the sequence is completed although the functionis stopped mechanically.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 289/368
2008-10-21 PLC Programme, ROC L7 40CR (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
5.8 RHS, carousel rotation, clockwiseS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONORB119/RHS-arm in mid pos. X10-2/ONS111/Pos, to the left. D551-CH4/ON
Rotation starts B183/ACTIVE X13-1/ON X15-2/ON Y303A⇓ B183/Dis-ACTIVE X13-1/OFF
Rotation stops B183/ACTIVE X13-1/ON X15-2/OFF Y303A OFF⇓
Sequence complete
• To index additional steps, S111 can be kept in position.
5.9 RHS, carousel rotation, anti-clockwiseS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONORB119/RHS-arm in mid pos. X10-2/ONS111/Pos, to the right. D551-CH5/ON
Rotation starts B182/ACTIVE X14-8/ON X15-1/ON Y303B⇓ B182/Dis-ACTIVE X14-8/OFFRotation stops B182/ACTIVE X14-8/ON X15-1/OFF Y303B OFF
⇓
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 290/368
Sequence complete
• To index additional steps, S111 can be kept in position.
6. MONITORING FUNCTIONS 6.1 Low hydraulic oil level, engine shut down
B143/Open contact X11-8/OFF X11-3/OFF K200 OFF
6.2 High hydraulic oil temperatureB362/sensor reached 90°C X16-5 X11-3/OFF K200 OFF
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)
PLC-PROGRAMME EXPLANATION
DRILLRIG TYPE : ROC L8 30 and ROC L6 30 PLC TYPE : IFM CR0200/CR0020
PLC PART NUMBER : 3176 0001 50/3176 0001 55
INDEXINDEX .........................................................................................................................................................................................1 1. GENERAL FUNCTIONS ....................................................................................................................................................2
1.1 Power supply.....................................................................................................................................................................2 1.2 Engine cranking.................................................................................................................................................................2 1.3 Start Conditions for diesel engine....................................................................................................................................2 1.4a Pump 4 unload ................................................................................................................................................................2 1.4b Compressor blow off valve............................................................................................................................................2 1.5 Hydraulic oil pre-heating..................................................................................................................................................2 1.6 Indication light for hydraulic jack (option) .....................................................................................................................2 1.7 Diesel filler pump stop ..................................................................................................................................................... 3
2. TRAMMING FUNCTIONS .................................................................................................................................................3 2.1 Tramming low speed.........................................................................................................................................................3 2.2 Tramming high speed........................................................................................................................................................3
3. DRILLING FUNCTIONS ....................................................................................................................................................3 3.1 Dust Collector, suction control .......................................................................................................................................3 3.2 HECL-pump......................................................................................................................................................................3 3.3 Spray greasing activation (option) ...................................................................................................................................4 3.4 Anti-jamming activated by high rotation pressure ..........................................................................................................4 3.5 Feed lever, logic direction when anti-jamming is active ................................................................................................5 3.6a Low percussion with function self-holding...................................................................................................................5 3.7a High percussion with function self-holding..................................................................................................................5
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 291/368
3.6/3.7b Deactivation of magnetic holding for drill lever ....................................................................................................6 3.8 Impact hour counter..........................................................................................................................................................6 3.9 Automatic drill stop function...........................................................................................................................................6 3.10 Water mist system (option) ............................................................................................................................................6
4. RAPID FEED STOP FUNCTIONS ...................................................................................................................................7 4.1 Rapid feed stop, forward ..................................................................................................................................................7 4.2 Rapid feed stop, backwards, at break out position..........................................................................................................7 4.3 Rapid feed stop, backwards, at magazine level................................................................................................................7 4.4 Rapid feed stop, backwards, max .....................................................................................................................................7
5. ROD HANDLING FUNCTIONS ........................................................................................................................................8 5.1 Open Gripper.....................................................................................................................................................................8 5.2 Guide grip..........................................................................................................................................................................8 5.3 Hard grip............................................................................................................................................................................8 5.4 RHS, arm towards drill-centre with closed grippers (Tube in grippers) ........................................................................8
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay
1. GENERAL FUNCTIONS1.1 Power supplyS139/Ignition ON K11Fuse F13-F23/ON + 24V +24VX1/100 - ground connection
• When ignition key S139 is in position I, ignition ON, relay K11 is activated to allow power supply tofuse F13, F15-F22. Fuse F14 and F23 are powered directly aside from the K11 relay.
1.2 Engine crankingS130/Tramming pos. D552-CH2/ON X11-13/ON Y121A
X17-1/ON Y121BS180/Compressor load D552-CH9/OFF X18-8/OFF Y210A OFFE-stops S132A, S132Bnot activated X10-8/ONS139/Engine start D550-CH3/ON
B336/Pressure preventing X13-4/OFF X11-4/ON K5A
1.3 Start Conditions for diesel engineB366A,B/Compressor temp. X16-6,7 (< ~17.5mA)B362/Hydraulic oil temp. X16-5 (< ~15mA)B143/Hydraulic oil level X11-8/ON X11-3/ON K200
1.4a Pump 4 unload
S130/Tramming pos. D552-CH2/ON X11-13/ON Y121AS139/Engine start D550-CH3/ON X17-1/OFF Y121B OFFS139/Ignition D550-CH4/ON X17-1/ON Y121B
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 292/368
• When the ignition switch S139 is release from starting position and re-springed back to the ignitionposition, the output X17-1 will be ON until the diesel motor has reached a revolution of 1000 rpm.
1.4b Compressor blow off valveS130/Tramming pos. D552-CH2/ON X11-13/ON Y121A S139/Engine start D550-CH3/ON X17-1/OFF Y121B OFFS139/Ignition D550-CH4/ON X17-1/ON Y121B
X17-16/ON Y186
• When the ignition switch S139 is released from starting position and re-springed back to ignitionposition, the output X17-16 will be ON until the diesel motor has reached a revolution of 1000 rpm.
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay1.7 Diesel filler pump stop
B352/Diesel level X13-6/appox. 23.5V X11-2/OFF K18 OFF
• Filler pump relay K18 connected to PLC output X11-2 is activated when the analogue signal read fromPLC input X13-6 is less than appox. 23.5V.
2. TRAMMING FUNCTIONS2.1 Tramming low speed
S130/Tramming pos. low D552-CH2/ON X11-13/ON Y121AX17-1/ON Y121BX11-1/ON Y169
S121/Chair in position D550-CH2/ONB184/Active X11-1/ONS174/S175/Activated D553/CH13 or 14/ON X10-9/10/ON Y206
X10-11/12/ON Y207
2.2 Tramming high speedS130/Tramming pos. high D552-CH3/ON X11-13/ON Y121A
X17-1/ON Y121BX11-1/ON Y169X11-14/ON Y122
S121/Chair in position D550-CH2/ONB184/Active (option) X11-1/ONS174/S175/Activated D553/CH13 or 14/ON X10-9/10/ON Y206
X10-11/12/ON Y207
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 293/368
3. DRILLING FUNCTIONS3.1 Dust Collector, suction control
S130/Drilling pos. D552-CH1/ON X18-2/ON Y250B118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S181/Suction pos. D551-CH12/ONS446/Low or High Imp. D550-CH9/10/ON X18-7/ON Y253
• When Impact is shut OFF there is a 4 seconds delay before X18-7 goes OFF and suction stops.
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay3.3 Spray greasing activation (option)
S130/Drilling pos. D552-CH1/ONS180/Compressor load (not PLC based condition)S449/Manual pos. D554-CH10/ON X15-8/ON Y552A
X16-11/ON Y552B
3.4 Anti-jamming activated by high rotation pressureS130/Drilling pos. D552-CH1/ON
B118/RHS-arm in carousel X10-5/ONS446/Low or High Imp. D550-CH9/10/ONB262/Not activated X16-16/OFFB134/ACTIVE X11-6/ON X11-11/ON Y109B134/De-activated X11-6/OFF X11-11/OFF Y109 O FF
X11-15/OFF Y101C OFFX12-1/OFF Y210B OFF
……4 sec….. X11-15/ON Y101CX12-1/ON Y210B
• Input X11-6 must be ON for a minimum of 0.8 sec in order to result in output Y11-11.• Y11-11 will remain active for a minimum of 2 sec or until the rotation pressure drops below the
setting of sensor B134.• When anti-jamming has been de-activated low feed pressure and low air pressure will be activated
for 4 sec. before going to high feed pressure and full air pressure.• When feed backwards is automatically activated during anti-jamming, impact will be OFF
mechanically. Since the drill bit extends out when feeding backwards and the impact piston won’tget any contact with the drill bit, so no impact is carried out when feeding backwards.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 294/368
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay3.5 Feed lever, logic direction when anti-jamming is active
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB134/ACTIVE X11-6/ON X11-11/ON Y109B262/ACTIVE X16-16/ON X11-11/OFF Y109 OFF
• Pulling the drill lever to feed backwards position activates B262. This will block the anti-jammingoutput X11-11 to allow logic function of the drill lever.
3.6a Low percussion with function self-holdingMagnetic holding on rotation clockwise and feeding forwards can only be achieved when the control leveris being pulled to the end position, pulling the lever only half way and then release would result in leverspringed back to the neutral position.
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)S452/Rapid feed mode off D550-CH11/OFF D550-CH7/ON Y179A
D550-CH8/ON Y179BD550-CH15/ON H452
S446A/Low impact D550-CH9/ON X17-14/ON Y116D550-CH16/ON H446
• To activate impact/flushing, press S446A for longer than 0.5 sec, pressing the button once more forshorter than 0.5 sec would deactivate impact/flushing and the lever returns to the neutral position.
• Diode H446 gives blinking signals when drilling with low impact.
3.7a High percussion with function self-holdingS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFB118/RHS-arm in carousel X10-5/ONS180/Compressor load (not PLC based condition)
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 295/368
S452/Rapid feed mode off D550-CH11/OFF D550-CH7/ON Y179AD550-CH8/ON Y179B
D550-CH15/ON H452S446A/Low impact D550-CH9/ON X17-14/ON Y116
D550-CH16/ON H446⇓ ⇓ ⇓ ⇓
S446B/High impact D550-CH10/ON X11-15/ON Y101CX12-1/ON Y210BX17-13/ON Y115X17-14/ON Y116
D550-CH16/ON H446
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay3.6/3.7b Deactivation of magnetic holding for drill lever
S453/Magnets off drill lever D550-CH12/ONORS452/Rapid feed mode D550-CH11/ON D550-CH7/OFF
D550-CH8/OFF
3.8 Impact hour counterS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact pos. D550-CH9/10/ON parameter in software
• As long as either of the impact switches S446A and S446B is activated, the PLC sends signals to theHEC-3 program in the display so the timer would keep counting.
3.9 Automatic drill stop functionparameter in software/Active X17-13/OFF Y115 O FF
X17-14/OFF Y116 OFF D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF X12-2/ON Y178
• Engine rpm will be lowered to 1500 rpm.• The drill lever is automatically shifted to rapid feed/threading mode when the desired drill
depth/length is reached.
3.10 Water mist system (option)S130/Drilling pos. D552-CH1/ONS180/Compressor load (not PLC based condition)S446A/R d d fl h i D550 CH9/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 296/368
S446A/Reduced flush air D550-CH9/ONAutomatic S448/Middle pos D554-CH4/ON X17-11/ON Y112A
X17-10/ON Y112C*Manual S448/Upper pos D554-CH3/ON X17-11/ON Y112A
X17-12/ON Y112BX17-10/ON Y112C*
• Valve Y112C is activated if the 400 litre water-mist system is used.
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay4. RAPID FEED STOP FUNCTIONS4.1 Rapid feed stop, forward
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
software stop X17-2/ON Y150
4.2 Rapid feed stop, backwards, at break out positionS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
S113/Take up rod string D551-CH9/ON
software stop X16-10/ON *Y149*Y149 only activated for 2 seconds.
4.3 Rapid feed stop, backwards, at magazine levelS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFF
D550-CH15/OFFS113/Take up rod string D551-CH9/ONsoftware stop X16-10/ON *Y149
*Y149 only activated for 2 seconds.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 297/368
4.4 Rapid feed stop, backwards, maxS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS452/Rapid feed mode D550-CH11/ON X12-2/ON K178
D550-CH7/OFFD550-CH8/OFFD550-CH15/OFF
software stop X16-10/ON Y149
• The stop signals come from HEC-3 program,and all the stop distances can be set in thedisplay. The signal is then sent to the PLC for 4.1
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay5. ROD HANDLING FUNCTIONS5.1 Open Gripper
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONS111/Top button pushed D550-CH6/ON X12-3/ON Y300
5.2 Guide grip
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONS111/RHS lever in neutral D551-CH2/3/4/5/6/OFF
..….0.5 sec…. X12-8/ON Y306• The activation of Y306 is delayed 0.5 sec by the PLC.
5.3 Hard grip S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFF
• Hard grip is the normal condition. No active inputs or outputs are required. Exceptions are Opengripper and Guide grip.
5.4 RHS, arm towards drill-centre with closed grippers (Tube in grippers)
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB118/RHS-arm in carousel X10-5/ONS111/Arm to drill centre D551-CH3/ON
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 298/368
S111/Arm to drill centre D551 CH3/ONOutlet hatch opens X15-4/ON Y310Arm movement starts X12-5/ON Y301B
⇓
Halfway sensor B119/ACTIVE X10-2/ONArm movement stops X12-5/OFF Y301B OFFGripper rotation starts towards drill centre X16-12/ON Y311B
⇓ Timer delay 3 sec after B119 is activated…Gripper rotation stops mechanically X16-12/ON Y311BArm movement continues X12-5/ON Y301BOutlet closes X15-4/OFF Y310 OFF
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay5.5 RHS, arm towards drill-centre with open grippers
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB118/RHS-arm in carousel X10-5/ONS111/Arm to drill centre D551-CH3/ONS111/Push the top button D551-CH6/ON
Outlet hatch is closed X15-4/OFF Y310 OFFRod grippers open X12-3/ON Y300Arm movement starts X12-5/ON Y301B
⇓ Half way sensor B119/ACTIVE X10-2/ONArm movement stops X12-5/OFF Y301B OFFGripper rot. starts toward drill centre X16-12/ON Y311B
⇓ Timer delay 3 sec after B119 is activated…Gripper rot. stops mechanically X16-12/ON Y311BArm movement continues X12-5/ON Y301B
⇓ Arm in drill centre B120/ACTIVE X10-3/ONArm movement stops mechanically X12-5/ON Y301BGripper rot. stopped mechanically X16-12/ON Y311B
⇓ Sequence complete
• The output X12-5 and X16-12 remain activated until the sequence is completed although thefunction is stopped mechanically.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 299/368
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay5.6 RHS, arm towards carousel with closed gripper (Tube in grippers)
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB178/Dis-ACTIVE X16-1/OFFB120/RHS-arm in drill centre X10-3/ONS111/Arm to carousel pos. D551-CH2/ON
Outlet hatch opens X15-4/ON Y310Arm movement starts X12-4/ON Y301A
⇓ Halfway sensor B119/ACTIVE X10-2/ONArm movement stops X12-4/OFF Y301A OFFGripper rot. towards carousel starts X18-1/ON Y311A
⇓ Timer delay 3 sec after B119 is activated…Gripper rot. stops mechanically X18-1/ON Y311AArm movement continues X12-4/ON Y301A
⇓ Magazine sensor B118/ACTIVE X10-5/ONArm movement stops mechanically X12-4/ON Y301AGripper rot. stopped mechanically X18-1/ON Y311AOutlet hatch is closed. X15-4/OFF Y310 OFF
⇓ Sequence complete
• The output X12-4 and X18-1 remain activated until the sequence is completed although the functionis stopped mechanically.
• Outlet hatch will remain opened until last condition is fulfilled (B118 activated).
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 300/368
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay5.7 RHS, arm towards carousel with open gripper
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/ACTIVE D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONS111/Push the top button. D551-CH6/ONS111/Arm to carousel pos. D551-CH2/ON
Outlet hatch is closed X15-4/OFF Y310 OFFOpen grippers X12-3/ON Y300Arm movement starts X12-4/ON Y301A
⇓ Halfway sensor. B119/ACTIVE X10-2/ONArm movement stops X12-4/OFF Y301A OFFGripper rot. towards carousel starts X18-1/ON Y311A
⇓ Timer delay 3 sec after B119 is activated…Gripper rot. stops mechanically X18-1/ON Y311AArm movement continues X12-4/ON Y301A
⇓ Arm in carousel B118/ACTIVE X10-5/ONArm in carousel stops mechanically X12-4/ON Y301AGripper rot. stopped mechanically X18-1/ON Y311A
⇓ Sequence complete
• The output X12-4 and X18-1 remain activated until the sequence is completed although the functionis stopped mechanically.
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 301/368
2008-10-21 PLC Programme, ROC L8 30 and ROC L6 30 (Bosal cabin)Function Signal from/position Input/status Output Valve/relay5.8 RHS, carousel rotation, clockwise
S130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONORB119/RHS-arm in mid pos. X10-2/ONS111/Pos, to the left. D551-CH4/ON
Rotation starts B183/ACTIVE X13-1/ON X15-2/ON Y303A⇓ B183/Dis-ACTIVE X13-1/OFF
Rotation stops B183/ACTIVE X13-1/ON X15-2/OFF Y303A OFF⇓
Sequence complete
• To index additional steps, S111 can be kept in position.
5.9 RHS, carousel rotation, anti-clockwiseS130/Drilling pos. D552-CH1/ON X11-1/OFF Y169 OFFS446/Impact switch off D550-CH9/10/OFFB379/Operator seat active D550-CH1/ONB120/RHS-arm in drill centre X10-3/ONORB119/RHS-arm in mid pos. X10-2/ONS111/Pos, to the right. D551-CH5/ON
Rotation starts B182/ACTIVE X14-8/ON X15-1/ON Y303B⇓ B182/Dis-ACTIVE X14-8/OFF
Rotation stops B182/ACTIVE X14-8/ON X15-1/OFF Y303B OFF⇓
Sequence complete
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 302/368
• To index additional steps, S111 can be kept in position.
6. MONITORING FUNCTIONS6.1 Low hydraulic oil level, engine shut down
B143/Open contact X11-8/OFF X11-3/OFF K200 OFF
6.2 High hydraulic oil temperatureB362/90°C X16-5 X11-3/OFF K200 OFF
L7 40
Bosal
13
13a
14
15
13b
68
64
65
63
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 303/368
L7 40
Bosal
31
30
45
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 304/368
47f 47e47c 47d47a 47b
L740
Bosal
5b
66
66f
66e
66d
66a
66c
66b
4s4r
4q
4l4k
4n4e4i 4p
4m
4a
4x
4b
4w
4u
4t
4c
10
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 305/368
4s
4j4f
33
4d
4y
34
L7 40
Bosal
91
90
89
87
88
86858483
82
80
80b
80a
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 306/368
64
65
63
68
13
13a
14
15
13b
L7 40
Bosal
CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 307/368
31
45
L7 40
Bosal
CR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 308/368
47f 47e47c 47d47a 47b
66
66f
66e
66d
66a
66c
66b
5b
4s4r
4q4p
4l4k
4n4m4e4i
4a
d
4x
4b
4w4t
4u
4c
10
L740
BosalCR
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 309/368
4j4f
3334
4d
4y
L7 40
Bosal
CR
97
95
96
93
94
91
89
88
90
87
86
8483
82
80a
80b
80
9885
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 310/368
L8 30
Bosal68
13
14
15
13a
13b
64
63
65
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 311/368
L8 30
Bosal45
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 312/368
47a 47b 47c 47d
L830
Bosal
66
66f
66e
66d
66a
66c
66b
4s4r
4q4p
4l4k
4n
4j
4i4m
4f
4e
4a
4b
4d
4c
4x
4w
4u
4t
10
5b
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 313/368
4j4f
4y
34 33
L8 30
Bosal
97
95
96
93
94
89
88
90
8786
8483
82
80a
80b
80
9885
9291
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 314/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 315/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 316/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 317/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 318/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 319/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 320/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 321/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 322/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 323/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 324/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 325/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 326/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 327/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 328/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 329/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 330/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 331/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 332/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 333/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 334/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 335/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 336/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 337/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 338/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 339/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 340/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 341/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 342/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 343/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 344/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 345/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 346/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 347/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 348/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 349/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 350/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 351/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 352/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 353/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 354/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 355/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 356/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 357/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 358/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 359/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 360/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 361/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 362/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 363/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 364/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 365/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 366/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 367/368
8/17/2019 ROC L6 L8 SystemDescriptionBosal
http://slidepdf.com/reader/full/roc-l6-l8-systemdescriptionbosal 368/368