Fire Safety ProductsProduct Overview

Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Conditioning | Air Curtains and Heating Products | Tunnel Fans

FIREDAMPER

EVACUATIONDAMPER

FIRE AIRGRILLE

MULTI-COMPARTMENTSMOKE DAMPER

FIREDAMPER

FIREDAMPER

EVACUATIONDAMPER

FIREDAMPER

MULTI-COMPARTMENTSMOKE DAMPER

FIRE SAFETY PRODUCTSprevent the spread of toxic gases, smoke and fire, help with evacuation, increase the effectivness of active fire protection systems and minimize the property damage.

PKIR3GCircular Fire Damper

Available in an explosion-proof versionDimension range (mm)

DN 100 up to 1000

PKIS3GRectangular Fire Damper

Available in an explosion-proof versionDimension range (mm)

W × H = 100 × 100 up to 1200 × 800

PKIS3GARectangular Fire Damper

Available in an explosion-proof versionDimension range (mm)

800 < W ≤ 1200& 100 ≤ H ≤ 300

PKIR-E60SCircular Fire Damper

Dimension range (mm) DN 100 up to 630

PKIS-EI90SRectangular Fire Damper

Available in an explosion-proof versionDimension range (mm)

W > 1200 and/or H > 800 up to 1600 × 1000

PKIS-EI120SRectangular Fire Damper

Available in an explosion-proof versionDimension range (mm)

W > 1200 and/or H > 800 up to 1600 × 1000

PKI-CCartridge Fire Damper

Dimension range (mm) DN 100 up to 200

Fire resistivity* II 2/- G IIB1396-CPR-0077

II 2/- G IIB1396-CPR-0077 Fire resistivity*

Fire resistivity* II 2/- G IIB1396-CPR-00761396-CPD-0061

II 2/- G IIB1396-CPD-0062 Fire resistivity*

1396-CPD-0069 Fire resistivity*

II 2/- G IIB1396-CPD-0062 Fire resistivity*

1396-CPD-0050 Fire resistivity*

* Detailed information about fire resistivity is on the back page.

FIRE DAMPERSSafety position: closed

DKIR1Single-compartment Circular Smoke DamperDimension range (mm) DN 100 up to 630

DKIS1Single-compartment Rectangular Smoke DamperDimension range (mm) W × H = 200 × 200 up to 1500 × 800

DKISMAMulti-compartment Smoke DamperDimension range (mm) W × H = 200 × 200 up to 1600 × 1000

EKIR-E60SCircular Evacuation DamperDimension range (mm) DN 100 up to 630

FGSFire Air GrilleDimension range (mm) 200 × 200 up to 800 × 1000

Fire resistivity*

1396-CPD-0069 Fire resistivity*

1396-CPD-0058 Fire resistivity*1396-CPR-0058 Fire resistivity*

1396-CPR-0112 Fire resistivity*

* Detailed information about fire resistivity is on the back page.

SMOKE DAMPERSSafety position: open or closed

EVACUATION DAMPERSSafety position: open

FIRE AIR GRILLESSafety position: closed

Product type

Dimensions range (mm)

Fire resistivity

Supporting construction

Installation - tested at underpressure (Pa)

Wet Dry Soft crossing Instal. kit On a wall Out of a wall

PKIR3GATEX

100 ≤ DN ≤ 400

EI60 (ve ho i ↔ o)S

ve 500 300 300 500 300 W 300 W

ho 500 300 300

EI90 (ve ho i ↔ o)S

ve 500 300 300 500 300 W 300 W

ho 500 300 300

EI120 (ve ho i ↔ o)S

ve 500 500

ho 500

400 < DN ≤ 630

EI60 (ve ho i ↔ o)S

ve 500 300 300 500 300 W 300 W

ho 500 300 300

EI90 (ve ho i ↔ o)S

ve 500 300 300 500

ho 500 300 300

EI120 (ve ho i ↔ o)S

ve 500 500

ho 500

630 < DN ≤ 1000

EI60 (ve ho i ↔ o)S

ve 500 300

ho 500

EI90 (ve ho i ↔ o)S

ve 500 300

ho 500

EI120 (ve ho i ↔ o)S

ve 500

ho 500

PKIR-E60S DN 100 up to 630 E60

(ve ho i ↔ o)S

ve 300 NOINS 300 NOINS

ho 300 NOINS 300 NOINS

PKI-C DN 100 up to 200

EI60 (ve ho i ↔ o)S

ve 300 300

ho 300

EI90 (ve ho i ↔ o)S

ve 300 300

ho 300

EI120 (ve ho i ↔ o)S

ve 300 300

ho 300

PKIS3GATEX

100 × 100 up to 1200 × 800

EI60 (ve ho i ↔ o)S

ve 500 300 300 500 KIT 300 W, P 300 W, P

ho 500 300 300

EI90 (ve ho i ↔ o)S

ve 500 300 300 500 KIT 300 W, P 300 W, P

ho 500 300 300

EI120 (ve ho i ↔ o)S

ve 500 500 KIT 300i→o W, P 300i←o W, P

ho 500 300

PKIS3GAATEX

800 < W ≤ 1200& 100 ≤ H ≤ 300

EI60 (ve ho i ↔ o)S

ve 300 300 P 300 P

ho

EI90 (ve ho i ↔ o)S

ve 300 300 P 300 P

ho

PKIS-EI90S MULTI, ATEX

W > 1200 and/or

H > 800 up to 1600 × 1000

EI90 (ve ho i ↔ o)S

ve 300 300 300 300 W 300 W

ho 300 300 300

PKIS-EI120SATEX

EI120 (ve ho i ↔ o)S

ve 300

ho 300 300

FGS200 × 200 up to

800 × 1000EI60Sa , EI90Sa * ve

Sa = 33 m3/

(hm2) at 50 Pa

Sa = 33 m3/

(hm2) at 50 Pa

DKIR1 DN 100 up to 630E600120 (ved i ↔ o)

S500 C10000 AA singleve 500

DKIS1200 × 200 up to

1500 × 800E600120 (ved i ↔ o)

S1500 C10000 AA single **ve

500 & 1500 **

DKISMA200 × 200 up to

1600 × 1000EI120 (vew i ↔ o)

S1500 Cmod AA multive 1500

EKIR-E60S DN 100 up to 630E60

(ve ho i ↔ o)S

ve 300 NOINS 300 NOINS

ho 300 NOINS 300 NOINS

www.systemair.com

E828

3 . I

MO

S-Sy

stem

air .

May

201

7

ATEX All ATEX fire dampers are designed for explosion hazardous areas classified as

MULTI Multi-installation in a wall: multiple neighbouring dampers always aligned horizontally and/or vertically with blade axis in horizontal orientation

KIT Up to dimensions W × H = 800 × 600 mm only

* The FGS has resistivity EI60Sa in the upper part & EI90Sa in the lower part of a vertical building element according to ETAG 026 Part 4 art. 2.4.2.1 par. 6

** DKIS1 has resistivity E600 120(ved i↔o)S500 C10000 AA single, for dimensions bigger than W × H = 1200 × 800 mm

P Installation on a wall or out of a wall with Promatect boards insulation for lower ceilings with resistivity EI30/45/60/90S; all PKIS3G and PKIS3GA up to dimensions W × H = 800 × 600 mm only

W Installation on a wall or out of a wall with mineral wool insulation, installation with EI90S up to DN = 400 mm, installation with EI60S up to DN = 500 mm

NOINS Installation on a wall or out of a wall without insulation

The tightness of the blade and the casing according to EN 1751:- 3C for PKIR3G as standard- 2C for other fire damper types as standard- 3C for other fire damper types for extra charge

Modulated fire dampers (the activation mechanism DV9-T-SR) are manufactured: - PKIR3G with DN ≥ 160 mm- PKIR-E60S in all dimensions- PKIS3G with H ≥ 160 mm

RIGID/FLEXIBLE WALL ONLY RIGID WALL/CEILING ONLY IN/ON THE DUCT

Legend

GOOD TO KNOWCurrent information on all fire safety products are available at www.systemair.com/FSPoverview