Post on 14-Apr-2018
Plug on Type MCBs & Distribution BoardsIntelligent Choice forPrestigious Buildings
New Offer
Table of ContentsQO Series Miniature Circuit Breakers
Specifications
QOvsRCBO Residual Current Circuit Breakerswith Integral Overcurrent Protection
QOE QWIK-GARD Current Circuit Breakerswith Integral Overcurrent Protection
QOE Miniature Circuit Breakers
LoadCentre Distribution Boards
Specifications
Rated Current 100A
Rated Current 200A
CLASSIC Metal Consumer Units
Specifications
Rated Current 100A
Certificates
1
Square D I-Line busbar trunking is designed and manufactured in afacility that is quality system registered by UL and BSI to ISO 9001.
CERT. NO.: 5732-1
ISO 9001: 2000CERT. NO.: 0086-1999-AQ-RGC-RvA
CERT. NO.: FM23076
2
3
4/5
6/7NEW
8
9
10
11
11
12/13
2
QO Series Miniature Circuit Breakers
Specifications
Comply with BS EN 60898.Comply with BS EN 60947-3 : 1992.Add i t i ona l sa fe ty requ i remen ts fo r Disconnectors and Switch Disconnectors as referred to in BS 7671.Trip-free handle ensures tripping even when the circuit breaker handle is held or locked in the ON position.To restore service, simply switch the indicative buttom from OFF to ON position once the fault has been cleared, which completely eliminates the cost and inconvenience of replacing fuse links or fuse wire.
All circuit breakers fit all LoadCentre Distribution Boards and Consumer Units in the range.Plug-on circuit breakers are tamperproof and provide positive connection to the busbar in one quick operation.Easy for installation and maintenance, with labour cost saved up to 50%.Current ratings from 6A to 63A, single, double and triple pole.Instantaneous trip type B, C and D.Rated voltage up to 240V AC single phase or 415V AC three phase 50/60Hz.
Full Range of QO Series Miniature Circuit Breaker Breakers
3
QO Series RCBO
QOvsRCBO Residual Current Circuit Breakerswith Integral Overcurrent Protection
Used in Square D consumer units, LoadCentre Distribution Boards.Compliance with International Standards: IEC 61009-2-2 and BSEN 61009-1, CE marked.Rated voltage: 240V AC, +10%, -15%.Frequency: 50...60 Hz.Class: AC.Ratings: 10-45 A to 40ºC.Breaking capacity as per IEC 61009: 6 kA.Tripping characteristics: Type C (5-10 In).Tripping time is in compliance with IEE wiring regulations BS7671.Sensitivities: 10 or 30 mA (for protection against direct and indirect contact).ON/OFF Indication:
Trip-free handle through an over-center toggle mechanism that ensure tripping even when the handle is held or locked at the ON position.Overload, short circuit, and earth fault currects are indicated by location of the handle in the OFF position.
Push-to-test Function:A Yellow push-test button “T” is positioned on the front of the device for testing that product is operationalThe smallest operating voltage for the test button: 200V AC (0.85 Un)
Connection:Phase in: plug-on tyepPhase & Neutral out: 1 to 16mm2 flexible or rigid cable (tightening torque 2 N.m)
Catalogue NumberSingle Pole
QO110vs6RCBO10QO160vs6RCBO10QO120vs6RCBO10QO132vs6RCBO10QO140vs6RCBO10QO145vs6RCBO10
QO110vs6RCBO30QO160vs6RCBO30QO120vs6RCBO30QO132vs6RCBO30QO140vs6RCBO30QO145vs6RCBO30
101010101010
303030303030
101620324045
101620324045
SensitivitymA
Rated CurrentA
-
-
-
-
--
QO132vs6RCBO30
4
QO Series RCBO
QOE QWIK-GARD Residual Current Circuit Breakerswith Integral Overcurrent Protection
Rated voltage of 220V to 240V AC, 50/60Hz, operating voltage: 50V 250V AC, 50/60Hz.Used in Square D Consumer Units, LoadCentre Distribution Boards and can be retrofitted to existing installations.Compliance with International Standards : Certfiied to IEC 60898 and IEC 61009, 10kA at 240V AC, 50/60Hz, CE market.ON/OFF Indication: ON/OFF marketings are on the face of the circuit breaker along with the international I/O markings.Handle Operation: Trip-free handle through an over-centre toggle mechanism that ensures tripping even when the handle is held or locked in the ON position.Trip Indication: Indication of a tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position. Indication of a tripped circuit breaker on residual current ground fault is by location of the handle in an intermediate position.Push-to-test Function: A push-to-test button is positioned on the front of the device for testing the residual current electronic trip circuit and mechanism tripping interface.Thermal Trip Element: Thermal trip elements are factory calibrated at 30ºC ambient temperature.Instantaneous trip level:- Type B: (3-5In) Overcurrent protection for sensitive equipment- Type C: (5-10In) Overcurrent protection for all application typesClass: ACResidual Current Protection: Residual ground-fault trip currents are factory set at 10mA, 30mA or 100mA.Trip Mechanism:
Loss of neutral Protection: Device will trip on loss of neutral and is sensitive to both AC and pulsating DC fault current. Device will trip on voltage between neutral and earth greater than 50V AC.Protection against reversed polarity (Phase and Neutral)Protection against nuisance tripping (compliance with IEC 61543 for EMC)
Mounting: Plug-on connection.
-
--
QOE120C03
5
QO Series RCBO
QOE QWIK-GARD Residual Current Circuit Breakerswith Integral Overcurrent Protection
QOE132C03
Catalogue Number
Single Pole
Maximum Earth FaultLoop Impedance Zs
OHMs at 50V AC (RCCB)
Short Circuit Capacity (Icn) : 10000A
5 Seconds 0.4 Seconds
QOE106B01QOE110B01QOE116B01QOE120B01QOE132B01
QOE106B03QOE110B03QOE116B03QOE120B03QOE132B03
Type B Instantaneous Trip (3In to 5In)1 - 161 - 161 - 161 - 161 - 16
1 - 161 - 161 - 161 - 161 - 16
575575575575575
575575575575575
50005000500050005000
16671667166716671667
50005000500050005000
16671667166716671667
500500500500500
500500500500500
610162032
610162032
1010101010
3030303030
QOE106C01QOE110C01QOE116C01QOE120C01QOE132C01
QOE106C03QOE110C03QOE116C03QOE120C03QOE132C03
QOE106C10QOE110C10QOE116C10QOE120C10QOE132C10
Type C Instantaneous Trip (5In to 10In)1 - 161 - 161 - 161 - 161 - 16
1 - 161 - 161 - 161 - 161 - 16
1 - 161 - 161 - 161 - 161 - 16
575575575575575
575575575575575
575575575575575
50005000500050005000
16671667166716671667
500500500500500
50005000500050005000
16671667166716671667
500500500500500
500500500500500
500500500500500
500500500500500
610162032
610162032
610162032
1010101010
3030303030
100100100100100
RatedCurrent
A
TerminalCapacity
Load L&N
mm2
Pigtail Wire ConnectionColor & LengthEarth
Yellow & Greenmm
NeutralBluemm
ResidualTrippingCurrent
mA
6
QO Series Miniature Circuit Breakers
QOE Miniature Circuit Breaker
QO110EC6
Grey in color.Instantaneous trip level types B & C.Indication of tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position & trip status window.
BS EN 60898, IEC 898 - Miniature Circuit BreakerBS EN 60947-3 : 1992Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 7671.
In compliance with specifications:
QO103EB6QO106EB6QO110EB6QO116EB6QO120EB6QO125EB6QO132EB6QO140EB6QO150EB6QO163EB6
Type B Instantaneous Trip (3In to 5In)361016202532405063
1 - 251 - 251 - 251 - 251 - 251 - 25
2.5 - 352.5 - 352.5 - 352.5 - 35
20.010.06.03.73.02.31.81.51.20.9
16.08.04.83.02.41.91.51.21.00.8
Catalogue Number
Single Pole
Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC
Short Circuit Capacity (Icn) : 6000A
5 Seconds 0.4 Seconds
Rated Current
A
Teminal Capacity
mm2
QO106EC6QO110EC6QO116EC6QO120EC6 QO125EC6QO132EC6QO140EC6QO150EC6QO163EC6
Type C Instantaneous Trip (5In to 10In)61016202532405063
1 - 251 - 251 - 251 - 251 - 25
2.5 - 352.5 - 352.5 - 352.5 - 35
10.06.03.73.02.31.81.51.20.9
4.02.41.51.21.00.80.60.50.4
Catalogue Number
Single Pole Double Pole Triple Pole
Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC
Short Circuit Capacity (Icn) : 6000A
5 Seconds 0.4 Seconds
Rated Current
A
Teminal Capacity
mm2
QO206EC6QO210EC6QO216EC6QO220EC6 QO225EC6QO232EC6QO240EC6QO250EC6QO263EC6
QO306EC6QO310EC6QO316EC6QO320EC6 QO325EC6QO332EC6QO340EC6QO350EC6QO363EC6
7
QO Series Miniature Circuit Breakers
QOE Miniature Circuit Breaker
QO132EC10
QO232EC10
QO332EC10
Catalogue Number
Single Pole
Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC
QO103EB10QO106EB10QO110EB10QO116EB10QO120EB10QO125EB10QO132EB10QO140EB10QO150EB10QO163EB10
Type B Instantaneous Trip (3In to 5In)361016202532405063
1 - 251 - 251 - 251 - 251 - 251 - 25
2.5 - 352.5 - 352.5 - 352.5 - 35
20.010.06.03.73.02.31.81.51.20.9
16.08.04.83.02.41.91.51.21.00.8
Short Circuit Capacity (Icn) : 10000A
5 Seconds 0.4 Seconds
Rated Current
A
Teminal Capacity
mm2
QO106EC10QO110EC10QO116EC10QO120EC10 QO125EC10QO132EC10QO140EC10QO150EC10QO163EC10
Type C Instantaneous Trip (5In to 10In)61016202532405063
1 - 251 - 251 - 251 - 251 - 25
2.5 - 352.5 - 352.5 - 352.5 - 35
10.06.03.73.02.31.81.51.20.9
4.02.41.51.21.00.80.60.50.4
Catalogue Number
Single Pole Double Pole Triple Pole
Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC
Short Circuit Capacity (Icn) : 10000A
5 Seconds 0.4 Seconds
Rated Current
A
Teminal Capacity
mm2
QO206EC10QO210EC10QO216EC10QO220EC10 QO225EC10QO232EC10QO240EC10QO250EC10QO263EC10
QO306EC10QO310EC10QO316EC10QO320EC10 QO325EC10QO332EC10QO340EC10QO350EC10QO363EC10
8
Full Range of Miniature Circuit Breaker Boards
LoadCentre Distribution Boards with Finger Safe Protection
Specifications
Finger safe design for plug on - main busbar to maximize safety (live part have been totally insulated).Built-in with 4 pole main switch for complete isolation (TPN Type).Quick and easy to install.Accepts 1, 2 & 3 pole Plug-on circuit breakers and RCBOs.Range of incoming devices, including 4 pole.Brass neutral and earth terminal bars for every single pole outgoing way.Plenty of cable space, with knock-outs provided at top and bottom.
Used in offices, banks, IT buildings, hotels and commercial premises.Bluish grey color epoxy powder paint. Zinc coated corrosion resistant steel enclosure.Rated voltage up to 415V AC three phase.Main switch comply with BS EN 60439-3. Enclosure protection to BS EN 60529 IP41 (on request for higher IP rating).Comply with BSEN 60439 & IEC 60439.
Finger Safe
NEW
9
LoadCentre Distribution Boards
Rated Current 100A
CatalogueNumber
No. of Ways DimensionsHeight
mmWidth
mmDepth
mm
SQDLC104-100SQDLC106-100SQDLC108-100SQDLC110-100SQDLC112-100SQDLC114-100SQDLC116-100SQDLC118-100SQDLC120-100
LoadCentre TPN Type (Installed with 100A TPN Main Switch)468101214161820
SQDLC204-100SQDLC206-100SQDLC208-100SQDLC210-100SQDLC212-100SQDLC214-100SQDLC216-100SQDLC218-100SQDLC220-100
LoadCentre Lug Type (For direct connection w/o Main Switch)468101214161820
For installation ofCircuit Breaker orResidual CurrentCircuit Breakerwith IntegralOvercurrent Protection
Main isolator
SQDLC112-100
NEW
SAFE
453510567624681738795852909
380380380380380380380380380
121121121121121121121121121
453510567624681738795852909
380380380380380380380380380
121121121121121121121121121
10
LoadCentre Distribution Boards
Rated Current 200A
CatalogueNumber
No. of Ways DimensionsHeight
mmWidth
mmDepth
mm
SQDLC104-200SQDLC106-200SQDLC108-200SQDLC110-200SQDLC112-200SQDLC114-200SQDLC116-200SQDLC118-200SQDLC120-200
LoadCentre TPN Type (Installed with 200A TPN Main Switch)468101214161820
SQDLC204-200SQDLC206-200SQDLC208-200SQDLC210-200SQDLC212-200SQDLC214-200SQDLC216-200SQDLC218-200SQDLC220-200
LoadCentre Lug Type (For direct connection w/o Main Switch)468101214161820
For installation of Circuit Breaker orResidual CurrentCircuit Breakerwith IntegralOvercurrent Protection
NEW
SAFE
SQDLC112-200
5676246817387958529099661023
380380380380380380380380380
121121121121121121121121121
5676246817387958529099661023
380380380380380380380380380
121121121121121121121121121
Main isolator
11
CLASS Metal Consumer Units with Finger Safe Protection
Specifications
Catalogue Number No. of Ways DimensionsHeight
mmWidth
mmDepth
mm
SDCS14SDCS16SDCS110SDCS114SDCS118
100A Rated With Space for Incoming Device46101418
206206206206206
200238315391517
9898989898
Weight
kg
1.91.92.53.14
Catalogue Number Description DimensionsHeight
mmWidth
mmDepth
mm
QO1-100MPlug-on Incoming Device
100A double pole main switch 80 40 85
Weight
kg
0.28
Terminal Capacity
mm2
35
Finger safe design for plug on main busbar to maximize safety.Used in apartments. IT buildings, banks, hotels and commercial premises.Grey color, epoxy power paint.Zinc coated corrosion resistant steel enclosure.Rated voltage up to 240V AC single phase.Comply with BS EN 60439 & IEC 60439.Plug-on main switch complies with BS EN 60947-3 : 1992.Plug-on circuit breakers provide positive connection to the busbar in one quick operation, saving up to 50% on wiring and connection time.
SAFE
Rated Current 100A
SDCS14
Main Isolator
Circuit Breaker or RCBO
Finger Safe Main Busbar
12
Certificates
Miniature Circuit Breaker
Certificates
Consumer unit / LoadCentre
13
Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place,979 King’s Road, Quarry Bay, Hong KongTel: (852)2565 0621 Fax: (852)2811 1029Customer Care Centre: (852)2579 9699www.schneider-electric.com.hk
Macau Branch Office:Suite D, 13th Floor, The Macau Square,Avenida do Infante D. Henrique, No. 47-53, MacauTel : (853)2871 7488Fax: (853)2871 7499
SEHK/SQD/007 10/2010
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.
Plug on Type MCBs &Distribution Boards
Document No.: SEHK/SQD/007
Unit Mounting MCCBs & EnclosureDocument No.: SEHK/SQD/002
I-Line MCCBs & PanelboardsDocument No.: SEHK/SQD/001
Intelligent Choice forPrestigious Buildings
Intelligent Choice forPrestigious Buildings