Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature...

16
Plug on Type MCBs & Distribution Boards Intelligent Choice for Prestigious Buildings New Offer

Transcript of Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature...

Page 1: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

Plug on Type MCBs & Distribution BoardsIntelligent Choice forPrestigious Buildings

New Offer

Page 2: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers
Page 3: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

Table of ContentsQO Series Miniature Circuit Breakers

Specifications

QOvsRCBO Residual Current Circuit Breakerswith Integral Overcurrent Protection

QOE QWIK-GARD Current Circuit Breakerswith Integral Overcurrent Protection

QOE Miniature Circuit Breakers

LoadCentre Distribution Boards

Specifications

Rated Current 100A

Rated Current 200A

CLASSIC Metal Consumer Units

Specifications

Rated Current 100A

Certificates

1

Square D I-Line busbar trunking is designed and manufactured in afacility that is quality system registered by UL and BSI to ISO 9001.

CERT. NO.: 5732-1

ISO 9001: 2000CERT. NO.: 0086-1999-AQ-RGC-RvA

CERT. NO.: FM23076

2

3

4/5

6/7NEW

8

9

10

11

11

12/13

Page 4: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

2

QO Series Miniature Circuit Breakers

Specifications

Comply with BS EN 60898.Comply with BS EN 60947-3 : 1992.Add i t i ona l sa fe ty requ i remen ts fo r Disconnectors and Switch Disconnectors as referred to in BS 7671.Trip-free handle ensures tripping even when the circuit breaker handle is held or locked in the ON position.To restore service, simply switch the indicative buttom from OFF to ON position once the fault has been cleared, which completely eliminates the cost and inconvenience of replacing fuse links or fuse wire.

All circuit breakers fit all LoadCentre Distribution Boards and Consumer Units in the range.Plug-on circuit breakers are tamperproof and provide positive connection to the busbar in one quick operation.Easy for installation and maintenance, with labour cost saved up to 50%.Current ratings from 6A to 63A, single, double and triple pole.Instantaneous trip type B, C and D.Rated voltage up to 240V AC single phase or 415V AC three phase 50/60Hz.

Full Range of QO Series Miniature Circuit Breaker Breakers

Page 5: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

3

QO Series RCBO

QOvsRCBO Residual Current Circuit Breakerswith Integral Overcurrent Protection

Used in Square D consumer units, LoadCentre Distribution Boards.Compliance with International Standards: IEC 61009-2-2 and BSEN 61009-1, CE marked.Rated voltage: 240V AC, +10%, -15%.Frequency: 50...60 Hz.Class: AC.Ratings: 10-45 A to 40ºC.Breaking capacity as per IEC 61009: 6 kA.Tripping characteristics: Type C (5-10 In).Tripping time is in compliance with IEE wiring regulations BS7671.Sensitivities: 10 or 30 mA (for protection against direct and indirect contact).ON/OFF Indication:

Trip-free handle through an over-center toggle mechanism that ensure tripping even when the handle is held or locked at the ON position.Overload, short circuit, and earth fault currects are indicated by location of the handle in the OFF position.

Push-to-test Function:A Yellow push-test button “T” is positioned on the front of the device for testing that product is operationalThe smallest operating voltage for the test button: 200V AC (0.85 Un)

Connection:Phase in: plug-on tyepPhase & Neutral out: 1 to 16mm2 flexible or rigid cable (tightening torque 2 N.m)

Catalogue NumberSingle Pole

QO110vs6RCBO10QO160vs6RCBO10QO120vs6RCBO10QO132vs6RCBO10QO140vs6RCBO10QO145vs6RCBO10

QO110vs6RCBO30QO160vs6RCBO30QO120vs6RCBO30QO132vs6RCBO30QO140vs6RCBO30QO145vs6RCBO30

101010101010

303030303030

101620324045

101620324045

SensitivitymA

Rated CurrentA

-

-

-

-

--

QO132vs6RCBO30

Page 6: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

4

QO Series RCBO

QOE QWIK-GARD Residual Current Circuit Breakerswith Integral Overcurrent Protection

Rated voltage of 220V to 240V AC, 50/60Hz, operating voltage: 50V 250V AC, 50/60Hz.Used in Square D Consumer Units, LoadCentre Distribution Boards and can be retrofitted to existing installations.Compliance with International Standards : Certfiied to IEC 60898 and IEC 61009, 10kA at 240V AC, 50/60Hz, CE market.ON/OFF Indication: ON/OFF marketings are on the face of the circuit breaker along with the international I/O markings.Handle Operation: Trip-free handle through an over-centre toggle mechanism that ensures tripping even when the handle is held or locked in the ON position.Trip Indication: Indication of a tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position. Indication of a tripped circuit breaker on residual current ground fault is by location of the handle in an intermediate position.Push-to-test Function: A push-to-test button is positioned on the front of the device for testing the residual current electronic trip circuit and mechanism tripping interface.Thermal Trip Element: Thermal trip elements are factory calibrated at 30ºC ambient temperature.Instantaneous trip level:- Type B: (3-5In) Overcurrent protection for sensitive equipment- Type C: (5-10In) Overcurrent protection for all application typesClass: ACResidual Current Protection: Residual ground-fault trip currents are factory set at 10mA, 30mA or 100mA.Trip Mechanism:

Loss of neutral Protection: Device will trip on loss of neutral and is sensitive to both AC and pulsating DC fault current. Device will trip on voltage between neutral and earth greater than 50V AC.Protection against reversed polarity (Phase and Neutral)Protection against nuisance tripping (compliance with IEC 61543 for EMC)

Mounting: Plug-on connection.

-

--

QOE120C03

Page 7: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

5

QO Series RCBO

QOE QWIK-GARD Residual Current Circuit Breakerswith Integral Overcurrent Protection

QOE132C03

Catalogue Number

Single Pole

Maximum Earth FaultLoop Impedance Zs

OHMs at 50V AC (RCCB)

Short Circuit Capacity (Icn) : 10000A

5 Seconds 0.4 Seconds

QOE106B01QOE110B01QOE116B01QOE120B01QOE132B01

QOE106B03QOE110B03QOE116B03QOE120B03QOE132B03

Type B Instantaneous Trip (3In to 5In)1 - 161 - 161 - 161 - 161 - 16

1 - 161 - 161 - 161 - 161 - 16

575575575575575

575575575575575

50005000500050005000

16671667166716671667

50005000500050005000

16671667166716671667

500500500500500

500500500500500

610162032

610162032

1010101010

3030303030

QOE106C01QOE110C01QOE116C01QOE120C01QOE132C01

QOE106C03QOE110C03QOE116C03QOE120C03QOE132C03

QOE106C10QOE110C10QOE116C10QOE120C10QOE132C10

Type C Instantaneous Trip (5In to 10In)1 - 161 - 161 - 161 - 161 - 16

1 - 161 - 161 - 161 - 161 - 16

1 - 161 - 161 - 161 - 161 - 16

575575575575575

575575575575575

575575575575575

50005000500050005000

16671667166716671667

500500500500500

50005000500050005000

16671667166716671667

500500500500500

500500500500500

500500500500500

500500500500500

610162032

610162032

610162032

1010101010

3030303030

100100100100100

RatedCurrent

A

TerminalCapacity

Load L&N

mm2

Pigtail Wire ConnectionColor & LengthEarth

Yellow & Greenmm

NeutralBluemm

ResidualTrippingCurrent

mA

Page 8: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

6

QO Series Miniature Circuit Breakers

QOE Miniature Circuit Breaker

QO110EC6

Grey in color.Instantaneous trip level types B & C.Indication of tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position & trip status window.

BS EN 60898, IEC 898 - Miniature Circuit BreakerBS EN 60947-3 : 1992Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 7671.

In compliance with specifications:

QO103EB6QO106EB6QO110EB6QO116EB6QO120EB6QO125EB6QO132EB6QO140EB6QO150EB6QO163EB6

Type B Instantaneous Trip (3In to 5In)361016202532405063

1 - 251 - 251 - 251 - 251 - 251 - 25

2.5 - 352.5 - 352.5 - 352.5 - 35

20.010.06.03.73.02.31.81.51.20.9

16.08.04.83.02.41.91.51.21.00.8

Catalogue Number

Single Pole

Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC

Short Circuit Capacity (Icn) : 6000A

5 Seconds 0.4 Seconds

Rated Current

A

Teminal Capacity

mm2

QO106EC6QO110EC6QO116EC6QO120EC6 QO125EC6QO132EC6QO140EC6QO150EC6QO163EC6

Type C Instantaneous Trip (5In to 10In)61016202532405063

1 - 251 - 251 - 251 - 251 - 25

2.5 - 352.5 - 352.5 - 352.5 - 35

10.06.03.73.02.31.81.51.20.9

4.02.41.51.21.00.80.60.50.4

Catalogue Number

Single Pole Double Pole Triple Pole

Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC

Short Circuit Capacity (Icn) : 6000A

5 Seconds 0.4 Seconds

Rated Current

A

Teminal Capacity

mm2

QO206EC6QO210EC6QO216EC6QO220EC6 QO225EC6QO232EC6QO240EC6QO250EC6QO263EC6

QO306EC6QO310EC6QO316EC6QO320EC6 QO325EC6QO332EC6QO340EC6QO350EC6QO363EC6

Page 9: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

7

QO Series Miniature Circuit Breakers

QOE Miniature Circuit Breaker

QO132EC10

QO232EC10

QO332EC10

Catalogue Number

Single Pole

Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC

QO103EB10QO106EB10QO110EB10QO116EB10QO120EB10QO125EB10QO132EB10QO140EB10QO150EB10QO163EB10

Type B Instantaneous Trip (3In to 5In)361016202532405063

1 - 251 - 251 - 251 - 251 - 251 - 25

2.5 - 352.5 - 352.5 - 352.5 - 35

20.010.06.03.73.02.31.81.51.20.9

16.08.04.83.02.41.91.51.21.00.8

Short Circuit Capacity (Icn) : 10000A

5 Seconds 0.4 Seconds

Rated Current

A

Teminal Capacity

mm2

QO106EC10QO110EC10QO116EC10QO120EC10 QO125EC10QO132EC10QO140EC10QO150EC10QO163EC10

Type C Instantaneous Trip (5In to 10In)61016202532405063

1 - 251 - 251 - 251 - 251 - 25

2.5 - 352.5 - 352.5 - 352.5 - 35

10.06.03.73.02.31.81.51.20.9

4.02.41.51.21.00.80.60.50.4

Catalogue Number

Single Pole Double Pole Triple Pole

Maximum Earth FaultLoop Impedance ZsOHMs at 240V AC

Short Circuit Capacity (Icn) : 10000A

5 Seconds 0.4 Seconds

Rated Current

A

Teminal Capacity

mm2

QO206EC10QO210EC10QO216EC10QO220EC10 QO225EC10QO232EC10QO240EC10QO250EC10QO263EC10

QO306EC10QO310EC10QO316EC10QO320EC10 QO325EC10QO332EC10QO340EC10QO350EC10QO363EC10

Page 10: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

8

Full Range of Miniature Circuit Breaker Boards

LoadCentre Distribution Boards with Finger Safe Protection

Specifications

Finger safe design for plug on - main busbar to maximize safety (live part have been totally insulated).Built-in with 4 pole main switch for complete isolation (TPN Type).Quick and easy to install.Accepts 1, 2 & 3 pole Plug-on circuit breakers and RCBOs.Range of incoming devices, including 4 pole.Brass neutral and earth terminal bars for every single pole outgoing way.Plenty of cable space, with knock-outs provided at top and bottom.

Used in offices, banks, IT buildings, hotels and commercial premises.Bluish grey color epoxy powder paint. Zinc coated corrosion resistant steel enclosure.Rated voltage up to 415V AC three phase.Main switch comply with BS EN 60439-3. Enclosure protection to BS EN 60529 IP41 (on request for higher IP rating).Comply with BSEN 60439 & IEC 60439.

Finger Safe

NEW

Page 11: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

9

LoadCentre Distribution Boards

Rated Current 100A

CatalogueNumber

No. of Ways DimensionsHeight

mmWidth

mmDepth

mm

SQDLC104-100SQDLC106-100SQDLC108-100SQDLC110-100SQDLC112-100SQDLC114-100SQDLC116-100SQDLC118-100SQDLC120-100

LoadCentre TPN Type (Installed with 100A TPN Main Switch)468101214161820

SQDLC204-100SQDLC206-100SQDLC208-100SQDLC210-100SQDLC212-100SQDLC214-100SQDLC216-100SQDLC218-100SQDLC220-100

LoadCentre Lug Type (For direct connection w/o Main Switch)468101214161820

For installation ofCircuit Breaker orResidual CurrentCircuit Breakerwith IntegralOvercurrent Protection

Main isolator

SQDLC112-100

NEW

SAFE

453510567624681738795852909

380380380380380380380380380

121121121121121121121121121

453510567624681738795852909

380380380380380380380380380

121121121121121121121121121

Page 12: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

10

LoadCentre Distribution Boards

Rated Current 200A

CatalogueNumber

No. of Ways DimensionsHeight

mmWidth

mmDepth

mm

SQDLC104-200SQDLC106-200SQDLC108-200SQDLC110-200SQDLC112-200SQDLC114-200SQDLC116-200SQDLC118-200SQDLC120-200

LoadCentre TPN Type (Installed with 200A TPN Main Switch)468101214161820

SQDLC204-200SQDLC206-200SQDLC208-200SQDLC210-200SQDLC212-200SQDLC214-200SQDLC216-200SQDLC218-200SQDLC220-200

LoadCentre Lug Type (For direct connection w/o Main Switch)468101214161820

For installation of Circuit Breaker orResidual CurrentCircuit Breakerwith IntegralOvercurrent Protection

NEW

SAFE

SQDLC112-200

5676246817387958529099661023

380380380380380380380380380

121121121121121121121121121

5676246817387958529099661023

380380380380380380380380380

121121121121121121121121121

Main isolator

Page 13: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

11

CLASS Metal Consumer Units with Finger Safe Protection

Specifications

Catalogue Number No. of Ways DimensionsHeight

mmWidth

mmDepth

mm

SDCS14SDCS16SDCS110SDCS114SDCS118

100A Rated With Space for Incoming Device46101418

206206206206206

200238315391517

9898989898

Weight

kg

1.91.92.53.14

Catalogue Number Description DimensionsHeight

mmWidth

mmDepth

mm

QO1-100MPlug-on Incoming Device

100A double pole main switch 80 40 85

Weight

kg

0.28

Terminal Capacity

mm2

35

Finger safe design for plug on main busbar to maximize safety.Used in apartments. IT buildings, banks, hotels and commercial premises.Grey color, epoxy power paint.Zinc coated corrosion resistant steel enclosure.Rated voltage up to 240V AC single phase.Comply with BS EN 60439 & IEC 60439.Plug-on main switch complies with BS EN 60947-3 : 1992.Plug-on circuit breakers provide positive connection to the busbar in one quick operation, saving up to 50% on wiring and connection time.

SAFE

Rated Current 100A

SDCS14

Main Isolator

Circuit Breaker or RCBO

Finger Safe Main Busbar

Page 14: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

12

Certificates

Miniature Circuit Breaker

Page 15: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

Certificates

Consumer unit / LoadCentre

13

Page 16: Plug on Type MCBs & Distribution Boards - Schneider … · Full Range of QO Series Miniature Circuit Breaker Breakers. 3 QO Series RCBO QOvsRCBO Residual Current Circuit Breakers

Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place,979 King’s Road, Quarry Bay, Hong KongTel: (852)2565 0621 Fax: (852)2811 1029Customer Care Centre: (852)2579 9699www.schneider-electric.com.hk

Macau Branch Office:Suite D, 13th Floor, The Macau Square,Avenida do Infante D. Henrique, No. 47-53, MacauTel : (853)2871 7488Fax: (853)2871 7499

SEHK/SQD/007 10/2010

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.

Plug on Type MCBs &Distribution Boards

Document No.: SEHK/SQD/007

Unit Mounting MCCBs & EnclosureDocument No.: SEHK/SQD/002

I-Line MCCBs & PanelboardsDocument No.: SEHK/SQD/001

Intelligent Choice forPrestigious Buildings

Intelligent Choice forPrestigious Buildings