New Construction & Energy Codes

Post on 19-Apr-2022

3 views 0 download

Transcript of New Construction & Energy Codes

New Construction &

Energy Codes

Multifamily Building Lifecycle Series

September 26th, 2012

Introductions

The Heschong Mahone Group, Inc

Consulting on energy efficiency for buildings

Based in California:

– Headquarters in Sacramento region

– Offices in Bay Area and San Diego region

Expertise in multifamily and residential energy efficiency program implementation throughout California

www.h-m-g.com/multifamily

2 / 66 2

Using GoToWebinar

Minimize or expand the pane

View attendee list

Raise your hand

Choose audio mode

Type Questions

Questions will be taken at breaks, in the order received

3

/ 66 3

Today’s Agenda

1. 2013 Title 24 Energy Standards Preview

2. Funding Programs

3. Questions and Discussion

/ 66 4

/ 66 5

Energy Management

• Energy management guidelines

• Benchmarking and utility tracking

Tenant Programs and Education

• Tenant education

• SDG&E low income programs

Energy Upgrade Approach

• Trigger points

• Energy upgrade measures

• Funding finder tool

Energy Upgrade Implementation

• HERS assessment

• Programs and rebates

• Return on investment

New Construction • Integrated design

• New Title 24 Energy Standards

• Programs and rebates

Multifamily

Building

Lifecycle

Thank you to our sponsor

This webinar series is sponsored by San Diego Gas and Electric through the Local Government Partnership program with the City and County of San Diego.

/ 66 6

2013 Title 24 Standards

Preview

Section 1

Overview

Overarching Title 24 Topics

Low Rise Residential

– Mandatory measures

Question Break

– Prescriptive Changes

Question Break

High Rise Residential Updates

– Mandatory Measures

– Prescriptive Changes

Question Break

/ 66 8

Overarching Topics

Section 1A

Why Energy Standards?

Reduce energy costs

Increase availability and reliability of electricity

Improve occupant comfort

Reduce the impact on the environment

/ 66 10

Why Change?

2013 Update drivers:

California Energy Efficiency Strategic Plan

By 2020 – All new residential construction net

zero energy

– Low income single, multi-family homes more energy efficient

By 2030 – All new nonresidential construction net

zero energy

HVAC industry transformed for optimal system performance

/ 66 11

Overarching Updates

• January 1, 2014 Implementation date

• Application for permit on or after this date use 2013 Standards

• The Standards ‘subchapters’ have been renumbered

• Section 150 becomes 150.0

• Section 151 becomes 151.0

/ 66 12

Overarching Updates

• TDV (Time Dependent Value) multipliers are changing

• Electricity, natural gas, propane

• (Energy units) X (Applicable TDV multiplier)

• Multipliers vary by:

• Energy type, climate zone, building type, date and hour

/ 66 13

Overarching Updates

Values for TDV energy will increase

Multipliers for electricity and Propane increase significantly

/ 66 14

Overarching Updates

A central data registry or repository for all residential HERS and

Nonresidential compliance

documents to be created

/ 66 15

Overarching Updates

• New weather files from 2009 NREL data for compliance performance software

/ 66 16

Overarching Updates

• There is only 1 low rise residential alternative component package (prescriptive)

• Component Package A

/ 66 17

Low Rise Residential

Mandatory Measures

Section 1B

Residential – Mandatory Measures

• Minimum building energy measures

• Building envelope

• Fireplaces

• Space conditioning

• Water heating

• Ducts and fans

• Pools and spas

• Lighting

/ 66 19

Residential – Mandatory Measures

• Frame wall insulation -> R15

• Ceiling/roof insulation ->R30

• Raised floor insulation ->R19

• Crawlspaces to have vapor retarder at earth floor (all CZ)

/ 66 20

Residential – Mandatory Measures

• Maximum fenestration U-factor = 0.58

• Can average across entire home HERS Duct testing added

/ 66 21

Residential – Mandatory Measures

• HERS Duct testing added

• Minimum duct insulation = R6

• Condensing units located a minimum 5 feet away from dryer vent

/ 66 22

Residential – Mandatory Measures

• Water System Piping Insulation:

• ALL piping:

• with diameter of ¾” or larger

• associated with recirculation systems (regardless of diameter)

• Hot water pipes from the heating source to the kitchen fixtures

• Buried below grade hot water piping:

• Installed in water proof and non-crushable casing/sleeve

• To allow for installation, removal and replacement

/ 66 23

Residential – Mandatory Measures

• Residential Lighting

• No change to the kitchen 50%

• ALL kitchen lighting controlled

• Vacancy sensor or dimmer

• Bathroom

• Needs 1 high efficacy fixture AND

• All other lighting to be high efficacy or controlled by vacancy sensor

• Garages, Laundry and Utility rooms

• Hard wired lighting MUST be high efficacy AND

• Be controlled by vacancy sensor

/ 66 24

Residential – Mandatory Measures

• Low Rise Multifamily Outdoor Lighting

• Buildings with 4+ dwelling units:

• Private patios, entrances, balconies, porches

• Parking/Carports (less than 8 vehicles)

• Must be high efficacy, or controlled by a photocell and motion sensor

• All other areas comply with nonresidential outdoor lighting

• Same for parking lots or carports with 8 or more vehicles

/ 66 25

Residential – Mandatory Measures

• Low Rise Multifamily Interior Common Areas

• Total interior common area = 20% or less CFA, shall be:

• High efficacy or Controlled by an occupancy sensor

• Total Interior common area = more than 20% CFA

• Comply with Nonresidential standards

• Corridors and stairwells

• Controlled by occupant sensors

• Turn full on-full off from all entryways or exits

/ 66 26

Residential – Mandatory Measures

• Continuous operation of air handler cannot be used to meet ventilation requirements plus air flow is HERS verified

• Return Duct Sizing

• Less than 30’ in length

• Labeled for airflow

• Follow Table 150.0 for sizing

• OR HERS test for airflow and the fan watt draw

/ 66 27

Residential – Mandatory Measures

• Solar Ready - Occupancies covered:

• SF located in subdivisions w-10 or more homes

• Low rise multifamily

• High rise multifamily w-10 stories or less

• Solar Zone

• Single Family = 250 sqft • Exception for 3+ story homes, 150 sqft

• Multifamily (LR & HR)

• 15% of total roof area

/ 66 28

Questions? Comments?

Low Rise Residential Prescriptive changes and how they

affect performance compliance

Section 1C

Residential – Prescriptive Changes

• Frame Walls above grade (All CZ)

• R15+R4

• R13+R5

• Mass Walls Above Grade

• Interior R13 in all CZ except 16 (R17)

• Exterior R8 in all CZ except 16 (R13)

• Mass Walls Below Grade

• Interior R13 in all CZ except 16 (R15)

• Exterior R5 in CZ 1-13, R10 in 14-15, R19 in CZ 16

/ 66 31

Residential – Prescriptive Changes

• Radiant Barrier required in all CZ except 1 and 16

• Max U-factor in all CZ changed 0.32

• Max SHGC changed to 0.25

• No thermal mass requirement in any CZ

• Whole house fan requirement added for CZ8 – 14

• Duct insulation increases in some CZ to R-8

/ 66 32

Residential – Performance

• ACM still under development

• New software will feature a new simulation “engine”

• California Simulation Engine (CSE)

• More accurately estimate:

• Solar gain impacts on cooling and peak loads

• Building shell, interior mass impacts

• Ventilation interaction with mass

• Add capability for comfort analysis, mechanical ventilation

• Build on UZM model

/ 66 33

Bruce Wilcox, 2011

Residential – Performance

• New CSE

• Simulations: more of them, more detailed

• Run times will be slower

• CEC to maintain “Compliance Manager” software

• Provides standard/proposed building modeling rules

• All software vendors will use this for Title 24 results

/ 66 34

Questions? Comments?

High Rise Residential

Section 1D

High Rise Residential

January 1, 2015 – All nonresidential compliances documents uploaded to HERS provider

– Registered versions issued by provider

– Registered versions required by building department

Applies to ALL nonresidential buildings

/ 66 37

High Rise Residential

Nonresidential Performance modeling

– Under development

Adding new building types

– Data Centers

– Computer rooms

Adding standard design system types

– Single zone VAV

– Warehouses without AC

/ 66 38

Building Commissioning

New Section 120.8

Definition:

– Systematic quality assurance

– Spans design and construction phases

– Includes verifying and documenting systems and components

Planned, designed, installed, tested

Operated, maintained - meeting project requirements

All new nonresidential buildings

– More than 10,000 square feet

– Includes multifamily high rise

/ 66 39

Building Commissioning Summary of requirements (more than

10,000sq ft) – Owner or owner’s representative project

requirements

– Basis of design

– Design phase review

– Commissioning measures in construction documents

– Commissioning plan

– Functional performance testing

– Documentation and testing

– Commissioning report

/ 66 40

Design Review

All nonresidential, hotel/motel, highrise residential

This is to encourage:

– Best practices in design

Easier to construct/maintain

– Title 24 compliant/above code

Two more Certificates of Compliance

– Design Review Kickoff

– Document Design Review

/ 66 41

Nonresidential (High Rise Res)

New Mandatory Insulation requirements (Section 120.7)

Weighted average U-factors

– Roof/Ceiling

Metal buildings 0.098 (R11)

Wood framed & Others 0.075 (R19 wood frame)

– Walls

Metal building 0.113 (R13); Metal Frame 0.098 (R8 rigid over frame)

Light Mass 0.44; Heavy Mass 0.69

Wood framed & Others 0.110 (R11)

Spandrels and Curtain 0.28

– Floors

Raised mass 0.269 or 3” of lightweight concrete

Other floors 0.071 (R11)

/ 66 42

Nonresidential (High Rise Res)

Prescriptive requirements for High Rise

– Table 140.3-C in the Standards

– Table is restructured

Cool Roof

– Low sloped = less than 2:12

– Steep sloped = more than 2:12

– Removed reference to weight of roofing product

/ 66 43

Nonresidential (High Rise Res)

Prescriptive requirements for High Rise, cont.

Fenestration

– Prescriptive table is reorganized

– Using area weighted performance ratings

– All values are for all climate zones

Max U-factor, Max RSHGC, Minimum VT

– Maximum ‘vertical’ fenestration window to wall ratio = 40%

/ 66 44

Nonresidential (High Rise Res)

Prescriptive requirements for High Rise, cont.

Air Barriers

– Materials and assemblies joined and sealed to prevent air leakage from conditioned spaces to unconditioned spaces

– Required for all other buildings in CZ 10 – 16 but…

– NOT for High Rise Residential

/ 66 45

Nonresidential High Rise Res

Solar Zones

Required on all nonresidential, high rise residential and hotel/motel buildings

Minimum of 15% of the roof area

See Section 110.10 for exceptions for locating solar zones

/ 66 46

Linda’s Key Take-a-ways and

Other Info

Section 1E

Other information

Compliance Manuals

– Draft Residential Version

Should be posted on or around October 8, 2012

– Draft Nonresidential Version

Should be posted on or around October 22, 2012

Pay attention, review the draft versions, send in your comments, concerns and/or suggestions

/ 66 48

Take-a-ways

It’s going to be challenging

It’s going to take project teamwork

Architects and/or Building designers – beware!

– No longer can you avoid knowing about Title 24

– No longer can buildings be designed and tossed to the energy consultant

It could be a lot of fun!

/ 66 49

Take-a-ways

Thank you!!

/ 66 50

Questions? Comments?

Funding Programs

Section 2

Funding Opportunities

Utility

– California Advanced Homes Program (CAHP)

– California Solar Initiative

Tax Credit/Deductions

– Federal tax deduction (179D)

– State (low-income housing, TCAC)

Grants

– Enterprise Green Communities

– LEED Affordable Housing

/ 66 53

California Advanced Homes Program

• Residential New Construction incentives from California’s investor-owned utilities (PG&E, SDG&E, SCE, SCG)

• Calculated incentives based on Title 24 compliance percent (must exceed 15%)

• Incentives increase incrementally with the performance of the home – from $200 to $10,000 per home or unit

• www.californiaadvancedhomes.com

/ 66 55

For more program information, please

see the CAHP Participant Handbook or

contact you utility representative.

CAHP Measure Trends Envelope

– Insulation

– Superior air seal

– Advanced wall systems

– Radiant barrier

Space heating and cooling – High efficiency HVAC

– Combined heating, cooling and domestic hot water systems

– No cooling in coastal climates

Domestic hot water (DHW) – High efficiency DHW

– Tankless DHW

– Combined systems

Increased HERS verifications

/ 66 56 Source: www.californiaadvancedhomes.com

CAHP Contacts San Diego Gas & Electric Company

Phone: (866) 631-1744 Email: NewHomes@sdge.com Web: www.sdge.com/construction

Southern California Edison Phone: (714) 973-5776 Email: Karen.Klepack@sce.com Web: www.sce.com

Southern California Gas Company Phone: (866) 563-2637 Email: NewHomes@socalgas.com Web: www.socalgas.com/construction

Pacific Gas and Electric Company Single-Family Phone: (866) 352-7457 Email: cahp@h-m-g.com

Pacific Gas and Electric Company Multi-Family Phone: (866) 352-7457 Email: cmfnh@h-m-g.com Web: multifamily.h-m-g.com (Heschong Mahone Group)

/ 66 57

Tax Credits (CA) Sustainable building

method (SBM) point scoring requirements – competitive credits

‘Application’ and ‘placed in service’ submittal phases

Minimum performance criteria

Team qualification criteria

www.treasurer.ca.gov/ctcac/sustainable

/ 66 59

Enterprise Grants Charrette Grants: Up to $5,000

to assist housing developers with integrating green building systems in their developments and engage in a serious discussion of green design possibilities.

Sustainability Training Grants: Up to $5,000 to cover the design and distribution of an operations and maintenance manual and the development and implementation of a green training curriculum.

www.enterprisecommunity.com/financing-and-development/grants

/ 66 60

Source: www.enterprisecommunity.com

LEED Grants The Affordable Green

Neighborhoods Grant Program will award grants and provide educational resources to affordable housing developers and related public agencies who choose to pursue LEED 2009 for Neighborhood Development certification.

www.usgbc.org/homes

/ 66 61

Source: www.usgbc.org

Other Resources

www.dsireusa.org

– Database of incentives for renewables and efficiency

http://energy.gov/savings

– Tax credits, rebates, and savings

www.energyupgradeca.org

– ‘Funding Finder’ for multifamily properties

/ 66 62

New Construction Webinar Series

Date Topic

Today Benchmarking and Multi-Family Buildings

April 17 ENERGY STAR v3: The Impact on Multi-Family Buildings

June 19 Post-Construction Energy Efficiency: Continued Savings Through Maintenance and Tenant Behavior

October 16 Heads Up: What the New Title 24 Means for Multi-Family

64

2012 Schedule

To register: http://multifamily.h-m-g.com/training/

/ 66

Questions? Comments?