MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

Post on 19-May-2022

3 views 0 download

Transcript of MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

1

MANUALFORUSEANDINSTALATION

STOVEMODELS:G3,G5

CETestedbytheDINEN

13240§15aB-VGAustria

Type1

ColorEmajld.o.o.–Alaginci87a–34000Požega–Croatia

www.color.hr

team@color.hr

2

DisposalofpackagingPackaging protects fireplace from damage during the transport. Packaging materials arechosenfromaspectsofenvironmentalandwaste,andcanberecycled.

PRACTICAL!

Woodenpartofpackagingcanbeusedforheating.Itisaffordabletocutitonsmallpiecesanduseitasfirewood.

Attention!

Priortoinstallationandstart,donotmisstocheckwhethertherewas,duetothetransportation,anydamageonthefunctionalparts(airregulators,mantle,seals,door,chimneyconnector,etc.).

Ifyouhavenoticeddamage,pleasecontactourcustomerservice.

Fireplacemaynotbemodified!

3

CongratulationsonpurchaseofthisfireplacefromtheproductionseriesofthecompanyColoremajld.o.o.Thismanualforusagewillintroduceyoutothefunctionsandproperhandlingofthefireplace.Buyerandusersareobligated,basedonthismanual,toinformthemaboutproperhandlingofthefireplace!Ourguaranteeisvalidonlyifthefollowingguidelinesarecomplied.

Pleasekeepthismanual,inordertoremindyourselfhowtoproperlyhandlethefireplacepriortothenextheatingseason.

1. Description

Fireplaceismadeofweldedsteelconstruction.Inthemiddlepartthereisstokeholepaneledwithisolation.Beneaththestablecastironbar,anashtrayislocated,andbeneaththeashtraythereiswoodstorage.Fireplaceisfromtheuppersideclosedwithheatingstorage.

Thisfireplaceworksontheprincipleofconvectionarea,inwhichtheairthatisinsideofthefireplace,warmsinairspace,andafterthewarming,getsoutfromthestoveintotheroom.

2. General

NationalandEuropeanstandards,localandconstructionregulations,fireprotectionlawandregulationsmustbeobligated.Becauseofthatinformthechimneysweepfromyourcountry.Theremustbeprovidedenoughfreshairintotheroomwherethefireplaceisinstalled.CalculationofchimneyisdoneaccordingtoDINEN13384-1andDINEN13384-2withspecificvalueswhichcanbeseeninthismanualunderthesection4.Yourfireplacecanbeequippedwithaconnectionfortheexternalairsupply(seeimage1).Intheroomwithcontrolledventilation,therecanbeconnectionofairsupplyfromtheoutside.Inthatcasetheadditionalpressuremonitoringintheroomisrequired.Therequiredconnectionisavailableasadditionalequipment.

Payattentiontothesealedtubepipes.Thetotallengthofpipeshouldnotbelongerthan6meters,donotcalculatereductions,aswellastopof3piecesof90°elbow.Atstandstillkeepbothregulatorsclosed,inorderforcoldairnottobeabletocirculatethroughoutthechimney.Duetothecoldoutsideair,condensationcanbeavoidedbyisolatingthepipes.Chimneysubpressuremustbeinaconditiontoovercomethoseadditionalresistances.FireplacesthataredescribedinthismanualaretestedthroughDINEN13240norm.Fireplacesofthistype1canbeconnectedonmulti-paneledchimneys,ifchimneydimensionsallowit.Yourchimneysignificantlycontributestoproperworkofyourfireplace.Recommendations:

• Workinglevelofchimney:min.5meters• Cross-sectionofsubpressuremax.160mm• Inanycase,letyourchimneybeexaminedbyanexpert!

Ifthefireplaceisconnectedtothemulti-paneledchimney,thaninanycasedonotremovethehelixthatclosesthedoor.Thedoormust,afterputtingfirewoodintothestokehole,self-close,inordertopreventairinfluenceonsub-pressureandintensityoffire,andinordertoavoiddangerthatisrelatedwithstokehole.

3. Installationofthefireplaceandthefluepipeconnection

3.1. Fluepipeconnection

Forconnectiontothechimneythereshouldbeusedfluepipethathas2mmthickness.Allconnectorsfromfireplaceintothechimneymustbefirmandtightlyconnected.Becarefulthatfluepipedoesnotenterintothefreesectionofthechimney.Wallcoveringisrecommended.Horizontalpartofthefluepipe,comparedwithfireplace,mustbesituatedon90°orhigher.Fireplacesthathaveconnectiontouporback,switchablecapshouldbeonceagainsecurelyattachedwithscrews!

4

Picture1

Outdoorairsupply

3.2. Safetyrules

Atfireplaceinstallation,youmustcomplywithsafetyrules(FeuVo).Payattentiononminimumrequireddistancefromthewall,flammableelementsandonprotectionofthefloor!

Minimumdistance

4. Technicalspecifications

FireplaceModel

Strength

kW

TheAmount

OfExhaustGas

TheTemperature

Oftheoutgoinggas

Pressure

mbar

DiameterOfthe

Fluepipe

mm

Diameterofthe

connectionoftheoutdoorairsupply

mm

Heighttotheloweredgeofthefluepipeconnection

Fuel

Dimensions

H/W/L

mm

G3 7,2 0,08 252 0,12 150 100 900 Wood 1133X508,6X508,6

G3 7,4 0,08 - 0,12 150 100 900 Browncoalbriquette

1133X508,6X508,6

5. Generalinformationaboutfireplacework

Alwaysuseglove!Donotuseanyflammableliquidfluidsforlightingfire.Thedoorofthestokeholecanbeopenedonlywhenaddingfuel.Useonlysuitablefuels(seesection5.2.).Check,isthereenoughquantityoffreshairintheroom,whenworkingontheopenprinciple.Fireplacescanbeusedonlybyadults.Makesurethatchildrenareneveralonenearfireplace.Neverleavefireplaceforalongerperiodoftimewithoutsurveillance.Fireplacecanbeusedonlyaccordingtotheinstructionsinthismanual.

A 900mm IntheareaofthermalradiationB1 150mm Backspacebetweenwallandfireplace

B2 250mm SidespacebetweenwallandfireplaceC D

Attention!

Attoolowbutalsoattoohighpressuretheremaycometoaproblemwithfireplacework.

Ifthedeviationfromtherequiredpressure(section4)isover25%,suitablechangesonthechimneyshouldbemade.

5

5.1. Start

1. Primaryandsecondaryregulatorsopenmaximally!Becareful,ifthefluepipehasintegratedflapitshouldalsobeopenedmaximally.

2. 2-3cubesforfire,placeonthecenterofthestokeholeandputonitfirewood.

3. Lightthecubesandjustleanthedoor.Itpreventscondensationofgasonthecoldglass.

4. Afterapproximately5to10minutes,whenthefireisfullyburst,carefullyopenthedoor,put1to2piecesofthewoodintothestokehole,andthenclosethedoor.

5. Whentheamountofputtedfueledmaterialbecomeswellflamedandburst,andtheworkingtemperatureofthefireplaceisachieved,graduallymovetheprimaryairregulatorbackwards,buttheflamestillmustbefurthervisible.

Atoptimumsubpressureandqualitativefuel,theprimaryregulatorcanbecompletelyclosed.

6. Thedoorofthestokeholecanbeopenedagain,onlywhentheplacedquantityofthefuelisburned,andwhenyouwanttoputthenewfuel.

7. Itisrecommendedthatthesecondaryairregulatoriskeptmaximallyopened,inorderforthe“glasscleaning”tobecomemaximallyefficient,andtoavoidglass“fogging”.

8. Withfuelquantityregulatethenecessaryheatofyourroom.Excessivefireplaceworkbringstounnecessaryenvironmentoverload,moreoverstokehole,glassandfluepipepollution.

9. Whenusingbrowncoalbriquette,leaveprimaryairregulatoropen.

• Possibleodorappearancethatgeneratesduetoprotectivepaintdryingwilldisappearafterashortwhile.Iftheodorappears,openthewindowsoftheroomforaventilation.

ATTENTION!!!FORPROPPERREGULATIONOFPRIMARYANDSECUNDARYAIR;ASHTRYMUSTBETIGHTLYCLOSED!

5.2. Suitablematerialsforlighting

Fireplaceservesforcombustionofnaturalwood,woodenbriquetteandbrowncoalbriquette.Classicalwoodforfireplaceisbeechandbirch.Thesetypesofwoodhavethehighestburndegree;theyburncleanest,iftheyarestorageonadryplace.

Forlightingdonotuse:• Humidifiedwoodorwoodtreatedwithprotectionrepellants• Paperandcarton(exceptfordisposal)• Barkorplywood• Plasticorotherwaste

Freshwoodshouldbetornupandstored12to18monthsonopenstorage,butprotectedfromrain.Accordingtothemanual,therecanbeusedonlywoodwithmaximumhumidityof20%.

6

5. 4 Einstellen des Verriegelungsmechanismuses

Hebel für das öffnen der Seitenverkleidung. Der Hebel muss leicht nach vorne und nach oben geschoben werden, danach kann die Seitenverkleidung jeweils nach links oder rechts bewegt werden.

Auf diesem Bild wird der Fuss dargestellt mit welchem man den Kamin justieren kann, damit der automatische Verriegelungsmechanismus einwandfrei funktionieren kann.

7

5.3. Emptyingashtray

Becarefulthattheashtrayisregularlyemptiedandthattoomuchashisnotaccumulated.Otherwise,thereisdangerthatthebardoesnotcoolenoughanddamagesinthatway.Beforeemptyingtheashtray,checkisthereanyardorleftintheashtray.Eventhoughtheashiscoldfromtheoutside,itispossiblethatintheinneroftheashisardorwhichcanleadtotheinflammationofwastebin.

5.4. Cleaningandmaintenance

Fireplacecanbecleanedonlywhenitiscold!

Itisrecommendedtocleantheasheveryday,whichisoccurredduetocombustion.Neverleaveashaccumulatesinthetankinwaythatittouchesthebar,becauseitwoulddisruptcirculationofprimaryair,graduallyextinguishingtheflame;exceptthat,thebarwouldnotbecooledenoughanditwoulddamagepromptly.Payattentionwhilecleaningourfireplacestonotdamage,scratchedorbrakeessentialpartsofourproduct.Forcleaningsteelpartsusenon-abrasivedetergentsandsoftrag,andafterthecleaningwashitwelltoavoidthatdepositofdetergentdamagematerial.

Placeswheretheproductisequippedwithglass,cleaningtheglassshouldbedonewhenthefireplaceiscold,usingnormaldetergentforwashingtheglass.Inthecaseofsoliddepositsthatshouldberemoved,werecommendtousedetergentsthataresoldinstores,andthatareintendedtothatuse.

Afterwashingwashoutwithcleanwater,andiftherearecondensates,donotwaituntiltheyaredried,ratherswipethemimmediately.

5.5. Layoutandusageofairregulators

NoteinthecaseofchimneyfireIfthewrongortoohumidifiedflueisused,itispossiblethatachimneyfiresduetoaccumulationofdepositsinsideofthechimney.

• Immediatelycloseallairregulatorsonthefireplaceandcallthefiredepartment.• Afterthat,theprofessionalsmustsecure,thatontheentireexhaustsystemaren’tanycracksorleaks.

Attention!Fireplacecolorachievesitsultimatefirmnessonlyafterseveraltimesachievesitsratedtemperature.Toavoidcolordamaging,itisrecommendedtocleanthefireplacesurfaceonlywhenthecolorachievesitsultimatefirmness!

SECUNDARYOpen(push)Close(pullout)

PRIMARYOpen(push)Close(pullout)

8

6. Complaintsandservice

Forassessedmalfunctioncomplaintorbadproductfunctioningdoasinstructedinthewarrantycardandontheaddressofserviceworkshop.

Itisimportanttomention,iftherecomestoacomplaint,contacttheserviceworkshopinPožegaontelephonenumber034/312-303orfax034/312-305.Inthecaseofaneedourserviceteamwillcometoyou.Purchaseofthesparepartsyoucandothroughourservicesordirectlyfromafactory.Whendoingtheorder,writethenameofthesparepart.

Durationoftheproduct,intermsoflegalregulationsis6years.Duringthedurationperiod,wewillensureourserviceandsupplyofspareparts.

Properlylightafire

Pleasepayattentiononminimumspacebetweenwallsandflammableobjectsduringthelightingafire!

Stepno.1:Cubesforfirelayonthegridofthestokehole(leave2ribsofthegridfree),butdonotremoverestoftheashfromthestokehole.Nowputalittleoffuel(thickasafinger)acrossthecubeforfire(around15pieces),onthatput4to6logs(around5to6cmthick)andlightafire.

Duringthisphaseoflightingafire,thehandleforprimaryandsecondaryairshouldbemovedon“open”.Latchinsideofthefluepipeshouldbeopened.

Stepno.2:Fireplaceswithbigglassshouldhaveinthebeginningphaseoflightingalotofoxygen.Sequencetothat,thedoorofthestokeholemustatleast15to20minutesonlybeleaneduntiltheallwoodisinflame.Nowyoucanclosethedoor.

Stepno.3:Whenthefireplaceisafter1hourreachedtheworkingtemperature,youmayclosethehandlefortheprimaryair(seetheinstructions).

Stepno.4:Duringtheaddingoflargerwood,beneathitshouldbeonesmallerwood,inorderfortheremainingwoodfasterlightandinorderfornotproduceextrasmokeandpollutetheenvironment.

Basic:Duringtheaddingwoods,handlefortheprimaryairmustbealwaysopen.Afteroneandahalfhourofburning,youcanclosethehandleforthesecondaryair.

FIREPLACESHOULDNEVERBEFILLEDEXCESSIVELY.EXCESSIVEAMOUNTOFFUELORAIRFORCOMBUSTIONCANCAUSEOVERHEATANDDAMAGETHEFIREPLACE.