MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

8
1 MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5 CE Tested by the DIN EN 13240 § 15a B-VG Austria Type 1 Color Emajl d.o.o. – Alaginci 87 a – 34000 Požega – Croatia www.color.hr [email protected]

Transcript of MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

Page 1: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

1

MANUALFORUSEANDINSTALATION

STOVEMODELS:G3,G5

CETestedbytheDINEN

13240§15aB-VGAustria

Type1

ColorEmajld.o.o.–Alaginci87a–34000Požega–Croatia

www.color.hr

[email protected]

Page 2: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

2

DisposalofpackagingPackaging protects fireplace from damage during the transport. Packaging materials arechosenfromaspectsofenvironmentalandwaste,andcanberecycled.

PRACTICAL!

Woodenpartofpackagingcanbeusedforheating.Itisaffordabletocutitonsmallpiecesanduseitasfirewood.

Attention!

Priortoinstallationandstart,donotmisstocheckwhethertherewas,duetothetransportation,anydamageonthefunctionalparts(airregulators,mantle,seals,door,chimneyconnector,etc.).

Ifyouhavenoticeddamage,pleasecontactourcustomerservice.

Fireplacemaynotbemodified!

Page 3: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

3

CongratulationsonpurchaseofthisfireplacefromtheproductionseriesofthecompanyColoremajld.o.o.Thismanualforusagewillintroduceyoutothefunctionsandproperhandlingofthefireplace.Buyerandusersareobligated,basedonthismanual,toinformthemaboutproperhandlingofthefireplace!Ourguaranteeisvalidonlyifthefollowingguidelinesarecomplied.

Pleasekeepthismanual,inordertoremindyourselfhowtoproperlyhandlethefireplacepriortothenextheatingseason.

1. Description

Fireplaceismadeofweldedsteelconstruction.Inthemiddlepartthereisstokeholepaneledwithisolation.Beneaththestablecastironbar,anashtrayislocated,andbeneaththeashtraythereiswoodstorage.Fireplaceisfromtheuppersideclosedwithheatingstorage.

Thisfireplaceworksontheprincipleofconvectionarea,inwhichtheairthatisinsideofthefireplace,warmsinairspace,andafterthewarming,getsoutfromthestoveintotheroom.

2. General

NationalandEuropeanstandards,localandconstructionregulations,fireprotectionlawandregulationsmustbeobligated.Becauseofthatinformthechimneysweepfromyourcountry.Theremustbeprovidedenoughfreshairintotheroomwherethefireplaceisinstalled.CalculationofchimneyisdoneaccordingtoDINEN13384-1andDINEN13384-2withspecificvalueswhichcanbeseeninthismanualunderthesection4.Yourfireplacecanbeequippedwithaconnectionfortheexternalairsupply(seeimage1).Intheroomwithcontrolledventilation,therecanbeconnectionofairsupplyfromtheoutside.Inthatcasetheadditionalpressuremonitoringintheroomisrequired.Therequiredconnectionisavailableasadditionalequipment.

Payattentiontothesealedtubepipes.Thetotallengthofpipeshouldnotbelongerthan6meters,donotcalculatereductions,aswellastopof3piecesof90°elbow.Atstandstillkeepbothregulatorsclosed,inorderforcoldairnottobeabletocirculatethroughoutthechimney.Duetothecoldoutsideair,condensationcanbeavoidedbyisolatingthepipes.Chimneysubpressuremustbeinaconditiontoovercomethoseadditionalresistances.FireplacesthataredescribedinthismanualaretestedthroughDINEN13240norm.Fireplacesofthistype1canbeconnectedonmulti-paneledchimneys,ifchimneydimensionsallowit.Yourchimneysignificantlycontributestoproperworkofyourfireplace.Recommendations:

• Workinglevelofchimney:min.5meters• Cross-sectionofsubpressuremax.160mm• Inanycase,letyourchimneybeexaminedbyanexpert!

Ifthefireplaceisconnectedtothemulti-paneledchimney,thaninanycasedonotremovethehelixthatclosesthedoor.Thedoormust,afterputtingfirewoodintothestokehole,self-close,inordertopreventairinfluenceonsub-pressureandintensityoffire,andinordertoavoiddangerthatisrelatedwithstokehole.

3. Installationofthefireplaceandthefluepipeconnection

3.1. Fluepipeconnection

Forconnectiontothechimneythereshouldbeusedfluepipethathas2mmthickness.Allconnectorsfromfireplaceintothechimneymustbefirmandtightlyconnected.Becarefulthatfluepipedoesnotenterintothefreesectionofthechimney.Wallcoveringisrecommended.Horizontalpartofthefluepipe,comparedwithfireplace,mustbesituatedon90°orhigher.Fireplacesthathaveconnectiontouporback,switchablecapshouldbeonceagainsecurelyattachedwithscrews!

Page 4: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

4

Picture1

Outdoorairsupply

3.2. Safetyrules

Atfireplaceinstallation,youmustcomplywithsafetyrules(FeuVo).Payattentiononminimumrequireddistancefromthewall,flammableelementsandonprotectionofthefloor!

Minimumdistance

4. Technicalspecifications

FireplaceModel

Strength

kW

TheAmount

OfExhaustGas

TheTemperature

Oftheoutgoinggas

Pressure

mbar

DiameterOfthe

Fluepipe

mm

Diameterofthe

connectionoftheoutdoorairsupply

mm

Heighttotheloweredgeofthefluepipeconnection

Fuel

Dimensions

H/W/L

mm

G3 7,2 0,08 252 0,12 150 100 900 Wood 1133X508,6X508,6

G3 7,4 0,08 - 0,12 150 100 900 Browncoalbriquette

1133X508,6X508,6

5. Generalinformationaboutfireplacework

Alwaysuseglove!Donotuseanyflammableliquidfluidsforlightingfire.Thedoorofthestokeholecanbeopenedonlywhenaddingfuel.Useonlysuitablefuels(seesection5.2.).Check,isthereenoughquantityoffreshairintheroom,whenworkingontheopenprinciple.Fireplacescanbeusedonlybyadults.Makesurethatchildrenareneveralonenearfireplace.Neverleavefireplaceforalongerperiodoftimewithoutsurveillance.Fireplacecanbeusedonlyaccordingtotheinstructionsinthismanual.

A 900mm IntheareaofthermalradiationB1 150mm Backspacebetweenwallandfireplace

B2 250mm SidespacebetweenwallandfireplaceC D

Attention!

Attoolowbutalsoattoohighpressuretheremaycometoaproblemwithfireplacework.

Ifthedeviationfromtherequiredpressure(section4)isover25%,suitablechangesonthechimneyshouldbemade.

Page 5: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

5

5.1. Start

1. Primaryandsecondaryregulatorsopenmaximally!Becareful,ifthefluepipehasintegratedflapitshouldalsobeopenedmaximally.

2. 2-3cubesforfire,placeonthecenterofthestokeholeandputonitfirewood.

3. Lightthecubesandjustleanthedoor.Itpreventscondensationofgasonthecoldglass.

4. Afterapproximately5to10minutes,whenthefireisfullyburst,carefullyopenthedoor,put1to2piecesofthewoodintothestokehole,andthenclosethedoor.

5. Whentheamountofputtedfueledmaterialbecomeswellflamedandburst,andtheworkingtemperatureofthefireplaceisachieved,graduallymovetheprimaryairregulatorbackwards,buttheflamestillmustbefurthervisible.

Atoptimumsubpressureandqualitativefuel,theprimaryregulatorcanbecompletelyclosed.

6. Thedoorofthestokeholecanbeopenedagain,onlywhentheplacedquantityofthefuelisburned,andwhenyouwanttoputthenewfuel.

7. Itisrecommendedthatthesecondaryairregulatoriskeptmaximallyopened,inorderforthe“glasscleaning”tobecomemaximallyefficient,andtoavoidglass“fogging”.

8. Withfuelquantityregulatethenecessaryheatofyourroom.Excessivefireplaceworkbringstounnecessaryenvironmentoverload,moreoverstokehole,glassandfluepipepollution.

9. Whenusingbrowncoalbriquette,leaveprimaryairregulatoropen.

• Possibleodorappearancethatgeneratesduetoprotectivepaintdryingwilldisappearafterashortwhile.Iftheodorappears,openthewindowsoftheroomforaventilation.

ATTENTION!!!FORPROPPERREGULATIONOFPRIMARYANDSECUNDARYAIR;ASHTRYMUSTBETIGHTLYCLOSED!

5.2. Suitablematerialsforlighting

Fireplaceservesforcombustionofnaturalwood,woodenbriquetteandbrowncoalbriquette.Classicalwoodforfireplaceisbeechandbirch.Thesetypesofwoodhavethehighestburndegree;theyburncleanest,iftheyarestorageonadryplace.

Forlightingdonotuse:• Humidifiedwoodorwoodtreatedwithprotectionrepellants• Paperandcarton(exceptfordisposal)• Barkorplywood• Plasticorotherwaste

Freshwoodshouldbetornupandstored12to18monthsonopenstorage,butprotectedfromrain.Accordingtothemanual,therecanbeusedonlywoodwithmaximumhumidityof20%.

Page 6: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

6

5. 4 Einstellen des Verriegelungsmechanismuses

Hebel für das öffnen der Seitenverkleidung. Der Hebel muss leicht nach vorne und nach oben geschoben werden, danach kann die Seitenverkleidung jeweils nach links oder rechts bewegt werden.

Auf diesem Bild wird der Fuss dargestellt mit welchem man den Kamin justieren kann, damit der automatische Verriegelungsmechanismus einwandfrei funktionieren kann.

Page 7: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

7

5.3. Emptyingashtray

Becarefulthattheashtrayisregularlyemptiedandthattoomuchashisnotaccumulated.Otherwise,thereisdangerthatthebardoesnotcoolenoughanddamagesinthatway.Beforeemptyingtheashtray,checkisthereanyardorleftintheashtray.Eventhoughtheashiscoldfromtheoutside,itispossiblethatintheinneroftheashisardorwhichcanleadtotheinflammationofwastebin.

5.4. Cleaningandmaintenance

Fireplacecanbecleanedonlywhenitiscold!

Itisrecommendedtocleantheasheveryday,whichisoccurredduetocombustion.Neverleaveashaccumulatesinthetankinwaythatittouchesthebar,becauseitwoulddisruptcirculationofprimaryair,graduallyextinguishingtheflame;exceptthat,thebarwouldnotbecooledenoughanditwoulddamagepromptly.Payattentionwhilecleaningourfireplacestonotdamage,scratchedorbrakeessentialpartsofourproduct.Forcleaningsteelpartsusenon-abrasivedetergentsandsoftrag,andafterthecleaningwashitwelltoavoidthatdepositofdetergentdamagematerial.

Placeswheretheproductisequippedwithglass,cleaningtheglassshouldbedonewhenthefireplaceiscold,usingnormaldetergentforwashingtheglass.Inthecaseofsoliddepositsthatshouldberemoved,werecommendtousedetergentsthataresoldinstores,andthatareintendedtothatuse.

Afterwashingwashoutwithcleanwater,andiftherearecondensates,donotwaituntiltheyaredried,ratherswipethemimmediately.

5.5. Layoutandusageofairregulators

NoteinthecaseofchimneyfireIfthewrongortoohumidifiedflueisused,itispossiblethatachimneyfiresduetoaccumulationofdepositsinsideofthechimney.

• Immediatelycloseallairregulatorsonthefireplaceandcallthefiredepartment.• Afterthat,theprofessionalsmustsecure,thatontheentireexhaustsystemaren’tanycracksorleaks.

Attention!Fireplacecolorachievesitsultimatefirmnessonlyafterseveraltimesachievesitsratedtemperature.Toavoidcolordamaging,itisrecommendedtocleanthefireplacesurfaceonlywhenthecolorachievesitsultimatefirmness!

SECUNDARYOpen(push)Close(pullout)

PRIMARYOpen(push)Close(pullout)

Page 8: MANUAL FOR USE AND INSTALATION STOVE MODELS: G3, G5

8

6. Complaintsandservice

Forassessedmalfunctioncomplaintorbadproductfunctioningdoasinstructedinthewarrantycardandontheaddressofserviceworkshop.

Itisimportanttomention,iftherecomestoacomplaint,contacttheserviceworkshopinPožegaontelephonenumber034/312-303orfax034/312-305.Inthecaseofaneedourserviceteamwillcometoyou.Purchaseofthesparepartsyoucandothroughourservicesordirectlyfromafactory.Whendoingtheorder,writethenameofthesparepart.

Durationoftheproduct,intermsoflegalregulationsis6years.Duringthedurationperiod,wewillensureourserviceandsupplyofspareparts.

Properlylightafire

Pleasepayattentiononminimumspacebetweenwallsandflammableobjectsduringthelightingafire!

Stepno.1:Cubesforfirelayonthegridofthestokehole(leave2ribsofthegridfree),butdonotremoverestoftheashfromthestokehole.Nowputalittleoffuel(thickasafinger)acrossthecubeforfire(around15pieces),onthatput4to6logs(around5to6cmthick)andlightafire.

Duringthisphaseoflightingafire,thehandleforprimaryandsecondaryairshouldbemovedon“open”.Latchinsideofthefluepipeshouldbeopened.

Stepno.2:Fireplaceswithbigglassshouldhaveinthebeginningphaseoflightingalotofoxygen.Sequencetothat,thedoorofthestokeholemustatleast15to20minutesonlybeleaneduntiltheallwoodisinflame.Nowyoucanclosethedoor.

Stepno.3:Whenthefireplaceisafter1hourreachedtheworkingtemperature,youmayclosethehandlefortheprimaryair(seetheinstructions).

Stepno.4:Duringtheaddingoflargerwood,beneathitshouldbeonesmallerwood,inorderfortheremainingwoodfasterlightandinorderfornotproduceextrasmokeandpollutetheenvironment.

Basic:Duringtheaddingwoods,handlefortheprimaryairmustbealwaysopen.Afteroneandahalfhourofburning,youcanclosethehandleforthesecondaryair.

FIREPLACESHOULDNEVERBEFILLEDEXCESSIVELY.EXCESSIVEAMOUNTOFFUELORAIRFORCOMBUSTIONCANCAUSEOVERHEATANDDAMAGETHEFIREPLACE.