Long Bo FT and Flanges

Post on 01-Jan-2016

22 views 0 download

Tags:

description

Long Bo FT and Flanges. April 12, 2012 talk Hans Jostlein. Based on Comments and Requirements from the April 4 presentation: Increase the distance between HV Feed and TPC Increase the distance between central purity monitor and TPC / HV feed - PowerPoint PPT Presentation

Transcript of Long Bo FT and Flanges

Long Bo FT and Flanges

April 12, 2012 talk

Hans Jostlein

04/20/23 Long Bo FT and Flanges 1

Requested Design Changes from 4/4/2012

04/20/23 Long Bo FT and Flanges 2

Based on Comments and Requirements from the April 4 presentation:

1.Increase the distance between HV Feed and TPC

1.Increase the distance between central purity monitor and TPC / HV feed

2.Raise the HV FT flange above the insulation atop the big 33 ½”) flange

to diminish icing danger

Implementation of new Design Requirements

04/20/23 Long Bo FT and Flanges 3

Move the TPC away from the Tank Center.This frees up radial space for the purity monitor and

the HV Feed

Raise the TPC to the same elevation as the central purity monitor,

maintaining the same minimum LAr depth.

04/20/23 Long Bo FT and Flanges 4

04/20/23 Long Bo FT and Flanges 5

04/20/23 Long Bo FT and Flanges 6

Additional Design Features: Bubbles

04/20/23 Long Bo FT and Flanges 7

Analyze bubble paths and Bubble Size Control

Add a tight fitting seal at the bottom of the PE sleeve. It will sea when cold

Conical bottom end of the PE sleeve to prevent bubble aggregation

Venting of the space surrounding the 7/8” center tube to its inside

Venting the 7/8 tube inside through tiny holes in the contact cup at the bottom. Hole size 0.2 mm requires 2 cm LAr head; we will use 0.5 mm or larger.

04/20/23 Long Bo FT and Flanges 8

Additional Design Features: Purging

04/20/23 Long Bo FT and Flanges 9

Purge the space surrounding the PE sleeve into the GAr space at the top.

Purge the GAr space near the top into an external purge line

Purge the GAr space near the TPC Signal Feedthrough into an external purge line

New Feedthrough DesignNew Features:

1.Top Flange raised above the top insulation2.Bubble stop insert at bottom of PE Sleeve (See later slide)3.Inverted cup/ spring contact arrangement (see later slide)4.Extended to great depth to avoid having an insulated support5.Bubble and purge management (see later slide)

04/20/23 Long Bo FT and Flanges 10

Additional Design Features: HV Contact Area

04/20/23 Long Bo FT and Flanges 11

In order to minimize the TPC assembly diameter, thus maximizing the stand-off distances of HV FT and Purity monitor,

We invert the usual arrangement:

The spring loaded finger is attached to the TPC cathode HV tubing, while the (inverted) cup is welded to the HV FT center tube.

This change turns out useful and effective for bubble control (see previous slide)

04/20/23 Long Bo FT and Flanges 12

Additional Design Features: Windows

04/20/23 Long Bo FT and Flanges 13

We will have two windows, both existing:

An 8” CF window and a 6” CF window.These will help during HV FT installation

04/20/23 Long Bo FT and Flanges 14

04/20/23 Long Bo FT and Flanges 15

04/20/23 Long Bo FT and Flanges 16

04/20/23 Long Bo FT and Flanges 17

Making the Long Bo High Voltage Fedthrough

Cutting grooves into the PE:

04/20/23 Long Bo FT and Flanges 18

Making the Long Bo High Voltage Fedthrough

Cutting grooves into the PE:

04/20/23 Long Bo FT and Flanges 19

Making the Long Bo High Voltage Fedthrough

Cutting grooves into the PE:

04/20/23 Long Bo FT and Flanges 20

04/20/23 Long Bo FT and Flanges 21

04/20/23 Long Bo FT and Flanges 22