LED SIGNALS IN
INDIAN RAILWAYS
WHAT IS LED?
IT IS A DIODE WHICH EMITS LIGHT OF REQUIRE COLOUR WHEN FORWARD BIASED.
INTERNAL STRUCTURE OF LED
Colour Wavelength Voltage Semiconductor Material
RED 610 < λ < 760 1.63 < ΔV < 2.03Aluminium gallium arsenide (AlGaAs)Gallium arsenide phosphide (GaAsP)Aluminium gallium indium phosphate (AlGaInP)Gallium(III) phosphide (GaP)
Yellow 570 < λ < 590 2.10 < ΔV < 2.18Gallium arsenide phosphide (GaAsP)Aluminium gallium indium phosphide (AlGaInP)Gallium(III) phosphide (GaP)
Green 500 < λ < 570 1.9[< ΔV < 4.0
(AlGaP) Indium gallium nitride (InGaN) / Gallium(III) nitride (GaN)Gallium(III) phosphide (GaP)Aluminium gallium indium phosphide (AlGaInP)Aluminium gallium phosphide
DOPING MATERIAL, WAVELENGTH AND OPERATING VOLTAGE FOR COLOUR EMITTED BY LED
WHAT IS LED SIGNALS?
IT IS REPLACEMENT FOR FILAMENT LAMP WITH LOT OF ADVANTAGES OVER DRAWBACK OF FILAMENT LAMP
OTHER SELECTION
BX110 V AC
NX110 V AC
Fuse 0.63 Amp
LED SIGNAL UNIT
AC I/P
DC I/P
MOTHER BOARD & HMU CARD #
#
ECR
UNIVERSAL CURRENT REGULATOR
Aspect control circuit with LED signal arrangement
UNDER GROUND CABLE
CLS Unit Relay room
ECR
OTHER SELECTION
BX110 V AC
NX110 V AC
Fuse 0.63 /2 Amp
##
OTHER SELECTION
BX110 V AC
NX110 V AC
Fuse 0.63 Amp
LED SIGNAL UNIT
AC I/P
DC I/P
MOTHER BOARD & HMU CARD #
#
ECR
UNIVERSAL CURRENT REGULATOR
UNDER GROUND CABLE
RELAY ROOM CLS UNIT
Comparison between filament lamp & LED circuit
Aspect control circuit arrangement with filament lamp & LED signal
ADVANTAGES OF LED SIGNALS
• Long life 1,00,000 hours .• Pre-focused. • Better visibility .• Very good short view .• No focusing on curved track.• Same type of ECR for all aspect and signal.• No phantom effect .
DISADVANTAGES OF LED SIGNALS
• Colour of LED change according to temperature and supply voltage.
• Its intensity of light is high which affect the sight of the driver.
Signal with Filament lamp & door open
Signal with LED lamp & door open
NO PHANTOM EFFECT
WHETHER LED EMITS NOMINATED COLOUR ONLY?
A good quality LED emits nominated colour only.
There is very remote possibility that it may emits wrong colour if biased current changes.
COMPONENT OF LED SIGNAL
FUSE LAMP CHECKING RELAY (ECR) HEALTH MONITORING UNIT (HMU) UNIVERSAL CURRENT
REGULATOR LED SIGNAL UNIT
COMPONENT OF LED SIGNAL
Health monitoring unit
Lamp checking relay ECR Universal current regulator
LED signal lighting unit
Fuse
FUSE TO BE USED WITH LED SIGNALS
Fuse shall be 0.63 Amps capacity.Whether fuse of 0.63 capacity is available in ND type open fuse?
ND type open fuse G type closed fuse
HEALTH MONITORING UNIT
Front View
Rear View
RELAY COMPATIBLE WITH LED SIGNALS
Any type of relay recommended (metal to carbon/ metal to metal )by Railway board can be useThere is a recommended ECR for LED signal The selection of jumper on the UCR shall be as per ECR used.
Sr Nob
Type of ECR Make
Suitability with LED signal
P-up & DA current Relay ContactsMain
C-ON
Route
Shunt
ON-Metal to Metal M/s ABB YES YES - - 180&110 ma 3F/3B
OFF-Metal to Metal M/s Siemens YES YES
- - 145&62ma 3F/3B front 2,12,13
& back 3,4 ,14
ON-Metal to Carbon
M/s CGL
Company code
YES YES YES YES
180&110 ma4F/B, front A1/A2 to
D1/D2Back A3/A4 toD3/D4QECX51
M/s Hytronic
s
HRC-1 180&110 ma
4F/B ,front A1/A2 to D1/D2
Back A3/A4 toD3/D4HMCR-1
108/110ma
3F/3B ,Front A1/A2,D1/D2 &
D3/D4Back A3/A4, A5/A6
&D5/D6LED AC
ECR-Metal to carbon
-QECX61
YES YES YES YES 108 & 72 ma4F/B , front A1/A2 to
D1/D2Back A3/A4 toD3/D4
LED DC ECR-Metal to
carbon-
QECR2 YES YES YES YES 80 &55ma
4F/B , front A1/A2 to D1/D2
Back A3/A4 toD3/D4Conventional
ECR Rest conventional ECR are not suitable for LED signal
Reference RDSO Latter Nob .STS/E EL-LED Dated 02.06.2006
RELAYS TO USED WITH LED SIGNALS
COMPONENT OF LED SIGNAL LIGHTING UNIT
Quality LEDs Sensors Poly-carbonet Dom
Power supply socket
Feed back socket
INPUT POWER SUPPLY, OUT PUT & FUNCTIONS
• Input to all type of LED signal unit is ±25% of 110 volts DC and AC.
• Input to LED signal unit for main aspect is taken from O/P of current regulator.
• O/P is beam nominated colour (110 Lux for OFF aspect & 120 Lux for ON aspect).
• Also gives feed back about light O/P to current regulator if sensors are provided.
INPUT POWER SUPPLY, OUT PUT & FUNCTIONS
Sr No LED signal unit FunctionIn put & connectio
nOut put
Minimum
Visibility
AC Immunity
AC I/P DC I/P
1
Main running signal
RED gives out red light beam
Optical output
Feedback to current regulator ( if sensors
are provided
DC & appro. 125% of Input of current regulator & current regulation ±2% & Direct
120 lux -
15% +25% 600Mts
AC noise immunity 60 Volts
300 volts AC
YELLOW gives out yellow light beam
GREENgives out
green light beam
110 lux -
15% +25%
2 Directional route indicator
gives out lunar white light beam
50 lux -15% +25% 400Mts
3 Calling ON signal gives out yellow light beam
50 lux -15% +25%
200Mts4 Shunt signal gives out lunar white
light beam 30 lux -15%
+25%
FRONT VIEW ON ASPECT RED OFF ASPECT YELLOW OFF ASPECT GREEN
REAR VIEW
LED SIGNAL UNIT FOR MAIN SIGNALS
WHETHER LED SIGNALS ARE AVAILABLE FOR MAIN SIGNAL ONLY ?
LED SIGNAL UNIT FOR ROUTE INDICATOR
LED SIGNAL UNIT FOR SHUNT SIGNAL
LED SIGNAL UNIT FOR CALLING ON SIGNAL
FRONT VIEW CALLING ON SIGNAL ROUTE INDICATOR SHUNT SIGNAL
REAR VIEW
LED SIGNAL UNIT FOR SUBSIDIARY SIGNALS
WHETHER LED LIGHTING UNIT IS FOR MAIN SIGNAL ONLY?
I/P POWER SUPPLY, O/P OF CURRENT UNIVERSAL REGULATOR
• Placed inside CLS unit.• I/P 110 ±20 volts AC/DC.• O/P 125% of I/P & always DC.• O/P Current regulation 2 %.
Sr No
Universal current regulator for
In put per unit Out put Function
current volts
1 Main running signal
Separate fixed in
CLS unit
AC 125 ma ± 5%
DC 105 ma ± 5%
AC/DC 110
VOLTS ± 20%
DC approxim
ate 125% of
I/P & current
regulation margin
2%
Supply constant regulate current to LED SIGNAL UNIT
Scope for adjustment of circuit current to suite pick up current of ECR
Scope for adjustment to suite cascaded and non-cascaded aspect control circuit.
Regulates current as per feedback from LED signal unit
2 Directional route indicator
Inbuilt
AC 25 ma ± 5%
DC 23 ma ± 5%
3 Calling ON signal
AC 125 ma ± 5%
DC 105 ma ± 5%
4 Shunt signal
AC 125 ma ± 5%
DC 105 ma ± 5%
I/P POWER SUPPLY, O/P & FUNCTIONS OF CURRENT UNIVERSAL REGULATOR
Note – parameter as per specification RDSO/SPN/153/2002
Sr No
Universal current regulator for
In put per unit Out put Function
current volts
1Main
running signal
Separate fixed in CLS
unit
AC 140 ma +10,-20 (rms)DC 125 ma
+10,-20 (rms)
AC/DC 110
VOLTS ± 25% DC
approximate
125% of I/P &
current regulation
margin 2%
Supply constant regulate current to LED SIGNAL UNIT
Scope for adjustment of circuit current to suite pick up current of ECR
Scope for adjustment to suite cascaded and non-cascaded aspect control circuit.
Regulates current as per feedback from LED signal unit
2 Directional
route indicator
Inbuilt
AC 25 ma ± 5%DC 23 ma ± 5%
AC/DC 110
VOLTS ± 20%
3 Calling ON signal
AC 150 ma +10,-20 (rmsAC 125 ma
+10,-20 (rms
4 Shunt signal
AC 55 ma ± 5%DC 50ma ± 5%
I/P POWER SUPPLY, O/P & FUNCTIONS OF CURRENT UNIVERSAL REGULATOR
Note – parameter as per specification RDSO/SPN/153/2004 effective from 1.1.2007
PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT
Transformer 110/12 Volts 40 VAMECR (If provided )Signal lighting unit Inner colour lens
Outer Clear lensLamp holderLampClamp
PROVISION OF LED SIGNAL IN EXISTING FILAMENT LAMP CLS
• OUTDOOR ARRANGEMENT• Items to be removed from CLS unit:
– CLS Transformer & Lamp – MECR (if provided)– Lamp holder & clamp assembly – inner & Outer lens
• Items to be fitted:– Current Regulator – LED light unit
• INDOOR ARRANGEMENT• Items to be removed/add from Relay room:• Check 110 AC fuse, shall be 0.6 Amps • ECR, if it is not as per RB guide lines• If required Aspect monitoring card per Aspect of
HMU
PROVISION OF LED SIGNAL IN EXISTING FILAMENT LAMP CLS
PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT
Signal lighting unit
PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT
Inner colour & outer clear lens
Lamp, holder & clamp
Signal transformer
MECR
FIXING OF LED SIGNAL UNIT & UNIVERSAL CURRENT REGULATOR
• Fuse of Aspect control circuit shall be 0.63 amps.• Existing ECR & shall be as RB guidelines.• Make the jumper settings on UCR & HMU to suite ECR.• The availability/non-availability of cascading in Aspect
control ckt.• Make the jumper setting (blanking/non-blanking) on UCR
accordingly.• Check whether HMU is in circuit OR bypass mode.
CHECKS- DURING REPLACEMENT LED SIGNAL IN EXISTING FILAMENT LAMP CLS