LED Signal

32
LED SIGNALS IN INDIAN RAILWAYS

description

Signal

Transcript of LED Signal

Page 1: LED Signal

LED SIGNALS IN

INDIAN RAILWAYS

Page 2: LED Signal

WHAT IS LED?

IT IS A DIODE WHICH EMITS LIGHT OF REQUIRE COLOUR WHEN FORWARD BIASED.

Page 3: LED Signal

INTERNAL STRUCTURE OF LED

Page 4: LED Signal

Colour Wavelength Voltage Semiconductor Material

RED 610 < λ < 760 1.63 < ΔV < 2.03Aluminium gallium arsenide (AlGaAs)Gallium arsenide phosphide (GaAsP)Aluminium gallium indium phosphate (AlGaInP)Gallium(III) phosphide (GaP)

Yellow 570 < λ < 590 2.10 < ΔV < 2.18Gallium arsenide phosphide (GaAsP)Aluminium gallium indium phosphide (AlGaInP)Gallium(III) phosphide (GaP)

Green 500 < λ < 570 1.9[< ΔV < 4.0

(AlGaP) Indium gallium nitride (InGaN) / Gallium(III) nitride (GaN)Gallium(III) phosphide (GaP)Aluminium gallium indium phosphide (AlGaInP)Aluminium gallium phosphide

DOPING MATERIAL, WAVELENGTH AND OPERATING VOLTAGE FOR COLOUR EMITTED BY LED

Page 5: LED Signal

WHAT IS LED SIGNALS?

IT IS REPLACEMENT FOR FILAMENT LAMP WITH LOT OF ADVANTAGES OVER DRAWBACK OF FILAMENT LAMP

OTHER SELECTION

BX110 V AC

NX110 V AC

Fuse 0.63 Amp

LED SIGNAL UNIT

AC I/P

DC I/P

MOTHER BOARD & HMU CARD #

#

ECR

UNIVERSAL CURRENT REGULATOR

Aspect control circuit with LED signal arrangement

UNDER GROUND CABLE

CLS Unit Relay room

Page 6: LED Signal

ECR

OTHER SELECTION

BX110 V AC

NX110 V AC

Fuse 0.63 /2 Amp

##

OTHER SELECTION

BX110 V AC

NX110 V AC

Fuse 0.63 Amp

LED SIGNAL UNIT

AC I/P

DC I/P

MOTHER BOARD & HMU CARD #

#

ECR

UNIVERSAL CURRENT REGULATOR

UNDER GROUND CABLE

RELAY ROOM CLS UNIT

Comparison between filament lamp & LED circuit

Aspect control circuit arrangement with filament lamp & LED signal

Page 7: LED Signal

ADVANTAGES OF LED SIGNALS

• Long life 1,00,000 hours .• Pre-focused. • Better visibility .• Very good short view .• No focusing on curved track.• Same type of ECR for all aspect and signal.• No phantom effect .

Page 8: LED Signal

DISADVANTAGES OF LED SIGNALS

• Colour of LED change according to temperature and supply voltage.

• Its intensity of light is high which affect the sight of the driver.

Page 9: LED Signal

Signal with Filament lamp & door open

Signal with LED lamp & door open

NO PHANTOM EFFECT

Page 10: LED Signal

WHETHER LED EMITS NOMINATED COLOUR ONLY?

A good quality LED emits nominated colour only.

There is very remote possibility that it may emits wrong colour if biased current changes.

Page 11: LED Signal

COMPONENT OF LED SIGNAL

FUSE LAMP CHECKING RELAY (ECR) HEALTH MONITORING UNIT (HMU) UNIVERSAL CURRENT

REGULATOR LED SIGNAL UNIT

Page 12: LED Signal

COMPONENT OF LED SIGNAL

Health monitoring unit

Lamp checking relay ECR Universal current regulator

LED signal lighting unit

Fuse

Page 13: LED Signal

FUSE TO BE USED WITH LED SIGNALS

Fuse shall be 0.63 Amps capacity.Whether fuse of 0.63 capacity is available in ND type open fuse?

ND type open fuse G type closed fuse

Page 14: LED Signal

HEALTH MONITORING UNIT

Front View

Rear View

Page 15: LED Signal

RELAY COMPATIBLE WITH LED SIGNALS

Any type of relay recommended (metal to carbon/ metal to metal )by Railway board can be useThere is a recommended ECR for LED signal The selection of jumper on the UCR shall be as per ECR used.

Page 16: LED Signal

Sr Nob

Type of ECR Make

Suitability with LED signal

P-up & DA current Relay ContactsMain

C-ON

Route

Shunt

ON-Metal to Metal M/s ABB YES YES - - 180&110 ma 3F/3B

OFF-Metal to Metal M/s Siemens YES YES

- - 145&62ma 3F/3B front 2,12,13

& back 3,4 ,14

ON-Metal to Carbon

M/s CGL

Company code

YES YES YES YES

180&110 ma4F/B, front A1/A2 to

D1/D2Back A3/A4 toD3/D4QECX51

M/s Hytronic

s

HRC-1 180&110 ma

4F/B ,front A1/A2 to D1/D2

Back A3/A4 toD3/D4HMCR-1

108/110ma

3F/3B ,Front A1/A2,D1/D2 &

D3/D4Back A3/A4, A5/A6

&D5/D6LED AC

ECR-Metal to carbon

-QECX61

YES YES YES YES 108 & 72 ma4F/B , front A1/A2 to

D1/D2Back A3/A4 toD3/D4

LED DC ECR-Metal to

carbon-

QECR2 YES YES YES YES 80 &55ma

4F/B , front A1/A2 to D1/D2

Back A3/A4 toD3/D4Conventional

ECR Rest conventional ECR are not suitable for LED signal

Reference RDSO Latter Nob .STS/E EL-LED Dated 02.06.2006

RELAYS TO USED WITH LED SIGNALS

Page 17: LED Signal

COMPONENT OF LED SIGNAL LIGHTING UNIT

Quality LEDs Sensors Poly-carbonet Dom

Power supply socket

Feed back socket

Page 18: LED Signal

INPUT POWER SUPPLY, OUT PUT & FUNCTIONS

• Input to all type of LED signal unit is ±25% of 110 volts DC and AC.

• Input to LED signal unit for main aspect is taken from O/P of current regulator.

• O/P is beam nominated colour (110 Lux for OFF aspect & 120 Lux for ON aspect).

• Also gives feed back about light O/P to current regulator if sensors are provided.

Page 19: LED Signal

INPUT POWER SUPPLY, OUT PUT & FUNCTIONS

Sr No LED signal unit FunctionIn put & connectio

nOut put

Minimum

Visibility

AC Immunity

AC I/P DC I/P

1

Main running signal

RED gives out red light beam

Optical output

Feedback to current regulator ( if sensors

are provided

DC & appro. 125% of Input of current regulator & current regulation ±2% & Direct

120 lux -

15% +25% 600Mts

AC noise immunity 60 Volts

300 volts AC

YELLOW gives out yellow light beam

GREENgives out

green light beam

110 lux -

15% +25%

2 Directional route indicator

gives out lunar white light beam

50 lux -15% +25% 400Mts

3 Calling ON signal gives out yellow light beam

50 lux -15% +25%

200Mts4 Shunt signal gives out lunar white

light beam 30 lux -15%

+25%

Page 20: LED Signal

FRONT VIEW ON ASPECT RED OFF ASPECT YELLOW OFF ASPECT GREEN

REAR VIEW

LED SIGNAL UNIT FOR MAIN SIGNALS

Page 21: LED Signal

WHETHER LED SIGNALS ARE AVAILABLE FOR MAIN SIGNAL ONLY ?

LED SIGNAL UNIT FOR ROUTE INDICATOR

LED SIGNAL UNIT FOR SHUNT SIGNAL

LED SIGNAL UNIT FOR CALLING ON SIGNAL

Page 22: LED Signal

FRONT VIEW CALLING ON SIGNAL ROUTE INDICATOR SHUNT SIGNAL

REAR VIEW

LED SIGNAL UNIT FOR SUBSIDIARY SIGNALS

WHETHER LED LIGHTING UNIT IS FOR MAIN SIGNAL ONLY?

Page 23: LED Signal

I/P POWER SUPPLY, O/P OF CURRENT UNIVERSAL REGULATOR

• Placed inside CLS unit.• I/P 110 ±20 volts AC/DC.• O/P 125% of I/P & always DC.• O/P Current regulation 2 %.

Page 24: LED Signal

Sr No

Universal current regulator for

In put per unit Out put Function

current volts

1 Main running signal

Separate fixed in

CLS unit

AC 125 ma ± 5%

DC 105 ma ± 5%

AC/DC 110

VOLTS ± 20%

DC approxim

ate 125% of

I/P & current

regulation margin

2%

Supply constant regulate current to LED SIGNAL UNIT

Scope for adjustment of circuit current to suite pick up current of ECR

Scope for adjustment to suite cascaded and non-cascaded aspect control circuit.

Regulates current as per feedback from LED signal unit

2 Directional route indicator

Inbuilt

AC 25 ma ± 5%

DC 23 ma ± 5%

3 Calling ON signal

AC 125 ma ± 5%

DC 105 ma ± 5%

4 Shunt signal

AC 125 ma ± 5%

DC 105 ma ± 5%

I/P POWER SUPPLY, O/P & FUNCTIONS OF CURRENT UNIVERSAL REGULATOR

Note – parameter as per specification RDSO/SPN/153/2002

Page 25: LED Signal

Sr No

Universal current regulator for

In put per unit Out put Function

current volts

1Main

running signal

Separate fixed in CLS

unit

AC 140 ma +10,-20 (rms)DC 125 ma

+10,-20 (rms)

AC/DC 110

VOLTS ± 25% DC

approximate

125% of I/P &

current regulation

margin 2%

Supply constant regulate current to LED SIGNAL UNIT

Scope for adjustment of circuit current to suite pick up current of ECR

Scope for adjustment to suite cascaded and non-cascaded aspect control circuit.

Regulates current as per feedback from LED signal unit

2 Directional

route indicator

Inbuilt

AC 25 ma ± 5%DC 23 ma ± 5%

AC/DC 110

VOLTS ± 20%

3 Calling ON signal

AC 150 ma +10,-20 (rmsAC 125 ma

+10,-20 (rms

4 Shunt signal

AC 55 ma ± 5%DC 50ma ± 5%

I/P POWER SUPPLY, O/P & FUNCTIONS OF CURRENT UNIVERSAL REGULATOR

Note – parameter as per specification RDSO/SPN/153/2004 effective from 1.1.2007

Page 26: LED Signal

PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT

Transformer 110/12 Volts 40 VAMECR (If provided )Signal lighting unit Inner colour lens

Outer Clear lensLamp holderLampClamp

Page 27: LED Signal

PROVISION OF LED SIGNAL IN EXISTING FILAMENT LAMP CLS

• OUTDOOR ARRANGEMENT• Items to be removed from CLS unit:

– CLS Transformer & Lamp – MECR (if provided)– Lamp holder & clamp assembly – inner & Outer lens

• Items to be fitted:– Current Regulator – LED light unit

Page 28: LED Signal

• INDOOR ARRANGEMENT• Items to be removed/add from Relay room:• Check 110 AC fuse, shall be 0.6 Amps • ECR, if it is not as per RB guide lines• If required Aspect monitoring card per Aspect of

HMU

PROVISION OF LED SIGNAL IN EXISTING FILAMENT LAMP CLS

Page 29: LED Signal

PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT

Signal lighting unit

Page 30: LED Signal

PARTS TO BE REMOVED IN SIDE THE CLS LIGHTING UNIT

Inner colour & outer clear lens

Lamp, holder & clamp

Signal transformer

MECR

Page 31: LED Signal

FIXING OF LED SIGNAL UNIT & UNIVERSAL CURRENT REGULATOR

Page 32: LED Signal

• Fuse of Aspect control circuit shall be 0.63 amps.• Existing ECR & shall be as RB guidelines.• Make the jumper settings on UCR & HMU to suite ECR.• The availability/non-availability of cascading in Aspect

control ckt.• Make the jumper setting (blanking/non-blanking) on UCR

accordingly.• Check whether HMU is in circuit OR bypass mode.

CHECKS- DURING REPLACEMENT LED SIGNAL IN EXISTING FILAMENT LAMP CLS