Features & Applications• Determinephaserelationshipsandapproximate
voltage,line-to-lineorline-to-ground• Featuretwofiberglasspoleswithendfittingsthreaded
forinterchangeableprobes• Probefittingscouplewithahigh-impedance
componentencasedineachpole• Tocompletetestcircuit,a22ft.lengthofinsulated
flexiblecablestoresonreelaffixedtoonepoleandconnectstovoltmeteronotherpole
• Simpletooperate,testerpolesfirstattachtotwo6ft.Epoxiglas®insulatinguniversalhandles(includedineachkitforproperworkingclearances)
• Probescanbebroughtintocontactwithconductorsappropriateforthemetertoreadphase-to-phaseorphase-to-groundvoltage
Single-Range Units• Forconvenienceondifferentsystems,toggle
ondual-rangeunitscanswitchcalibrationbetweentwoscalesonmeterface
• Canimprovereadabilityforlow-endvaluesonHiscale
• SwitchedtoLorange,thosevaluesdeflectneedlemoretogivemorefinitereadingsforsecondaryandDChi-potting
• Tocheckinstrumentbeforeandaftereachuse,test-pointjackinfrontofmeteracceptsplugfromPhasingMeterTester,nextpage
For URD testing, see Hi-Pot Adapters (page 2458) and Adapters for Elbows and Bushings (page 2472).
Accessories
Analog Phasing Testers
Dual-Range Meters 1 & 16 kV Unit 5 & 16 kV Unit
• for †Distribution Circuits
Distribution Phasing TestersSingle-Range Units
Dual-Range Units
Extension Resistors, as installed▲
H18765
*Eachkitincludestwo6’x1-1⁄4"-dia.Epoxiglas®universalhandleswithstoragebag,tester,hookprobes,caseandinstructionmanual†ToextendanyCHANCE16kVPhasingTesterfor48or80kVapplications,optionalExtensionResistorssimplythreadoninthefield
Extension Resistors
Catalog No. Description Weight
H1876 †16kVTesterKit* 271⁄2lb./12.4kg.
H18761 †16kVTesterHookProbes,CaseandManual
23lb./10.4kg.
T4032261 25kVTesterKit* 271⁄2lb./12.4kg.
H18767 40kVTester,HookProbes,CaseandManual
23lb./10.4kg.
T4030786 1&†16kVTesterKit* 271⁄2lb./12.4kg.
T4032311 5&†16kVTesterKit* 271⁄2lb./12.4kg.
T4032398 5&†16kVTesterOnly 23lb./10.4kg.
H18762 PairofExtensionResistorsforupto80kV(32"long)
6lb./2.7kg.
H18764 PairofExtensionResistorsforupto48kV(21"long)
4lb./1.8kg.
P6242 Bagfor48kVResistors 1lb./0.5kg.
P6244 Bagfor80kVResistors 11⁄4lb./0.6kg.
H17601 UniversalPole11⁄4"x6'—TwoNeeded
13⁄4lb./0.7kg.
P6436 BagforTwoPoles 1lb./0.5kg.
H18763 CaseonlyforTester 2lb./0.9kg.
H18766P PigtailHookProbe 1⁄4lb./0.1kg.
H18766S ShepherdHookProbe 1⁄4lb./0.1kg.
H18766 StraightProbe 1⁄8lb./0.1kg.
H18765 AngleProbe 1⁄8lb./0.1kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2453July 2018
Features & Applications• Versatileforpopulardistributionvoltages• Facilitatestestingbothundergroundandoverhead
systems• Basicfunctionsincludeidentifyingphasesandreading
line-to-lineorline-to-groundvoltage• URDaccessoriesintheKitalsopermitcable-fault
detectionviaDChi-potting• Consistsofhigh-impedancecomponentsencasedin
twofiberglasspoleswiththreadedendfittingsforoverheadprobesorURDadapters
• A22ft.-longcableconnectstovoltmeterpoleandstoresonreelpole
• TodetectfaultsonURDcable,Hi-PotAdapterconvertsACsourcetoDCpulse
• Effectivefieldmethodquicklytestsnew,repairedorsuspectspans
Ordering Information
• Tocheckinstrumentbeforeandafteruse,PhasingMeterTesterleadplugsintotest-pointjackbymeter
• Otherleadclipsontoeachprobe
• SwitchonMeterTesterreversespolarityforthoroughfield-checkingprocedure
• Completeinstructionsincluded
• Forconvenienceondifferentsystems,toggleonmeterhousingcanswitchcalibrationbetweenthetwoscalesonmeterface
• Improvesreadabilityforlow-endvaluesontheHi(16kV)scale
• SwitchedtoLo(5kV)range,valuesdeflectneedlemoretogivemorefinitereadings
Complete Kit includes:Two 6’ x 1-1/4"-dia. Epoxiglas® universal handles with storage bag, tester with instruction manual and two probes (shepherd hook and pigtail hook) in padded carrying case, plus four items below
TwoBushing
AdaptersOneDCHi-PotAdapter& Instructions
URD Accessories in Kit
PhasingMeterTester (withbattery)in Kit
Catalog No. Description WeightT4032557PhasingTesterKit311/2lb./14.2kg. with16kVHi-PotAdapter, 2URDBushingAdapters, PhasingMeterTester
Distribution Analog Phasing Tester Kitfor Overhead and Underground SystemsDual Range: 5kV & 16kV Scales
C4031762T4030857
H17601 HotstickP6436 BagC4030838
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2454 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
• Largedirect-readingdisplay• Determinephaserelationshipsandapproximate
voltage,line-to-lineorline-to-ground• Eachtesterconsistsoftwofiberglasspoleswithend
fittingsthreadedforinterchangeableprobes• Probefittingscouplewithhigh-impedancecomponent
encasedineachpole• Tocompletethetestcircuit,a22ft.lengthofinsulated
flexiblecablestoresonthereelaffixedtoonepoleandconnectstoelectronicdisplaymoduleonotherpole
• Simpletooperate,testerattachestotwo6ft.Epoxiglas®insulatinguniversalhandles(includedineachkitforproperworkingclearances)
• Probescanbebroughtintocontactwithconductorsfortestertodisplayphase-to-phaseorphase-to-groundvoltage
• PushbuttoncontrolspermiteasyselectionofoptionsfordisplayBacklightandHoldfeatures
• Whennotinuse,theunit’sSleepmodeautomaticallyconservesthebattery
Hi-Pot & Higher Voltage Test Accessories• Forundergroundcablehi-pottesting• 16kVKitC4033402includesaDCHi-PotAdapteron
page2455• Hi-pottestingcannotbedonewiththe40kVunit• Boththe16kVand40kVKitsincludeunderground
bushingandelbowadapters
Digital Phasing Testers
Large direct display with backlight and hold features
• Foroverheadsubtransmissionsystems,ExtensionResistorsareavailableasaccessoriesspecifictoeachDigitalPhasingTester
Available as accessories, Extension Resis-tors simply thread onto the Digital Phasing Tester in the field.
Each Basic Unit Digital Phasing Tester includes the tester unit with meter and reel poles, a pigtail hook probe, a shepherd hook probe, instruction manual and hard shell padded case.
16kV Digital Phasing Tester Basic Unit Cat. No. C4033369 (14 lb./6.4 kg.)
40kV Digital Phasing Tester Basic Unit Cat. No. C4033370 (141⁄2 lb./6.6 kg.) Hi-pot testing cannot be done with the 40kV unit.
Basic Units:
See next page for Tester Kits.
• 16kV and 40kV models, plus 80kV extensions• For Overhead & UndergroundDisplay With Backlight, Hold and Sleep Modes
Extension Resistors as installed for testing up to 80kV ➧
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2455July 2018
Digital Phasing Testers• For Overhead & Underground
Easy Verification Test• Tocheckinstrumentbeforeandafteruse,PhasingMeterTesterleadplugs
intotest-pointjackbymeter• Otherleadclipsontoeachprobe.SwitchonMeterTester• Testerreversespolarityforthorough,easyfield-checkingprocedure• Completeinstructionsareincludedwitheachunit
TwoT4030857
BushingAdapters
C4031762DC Hi-PotAdapter
C4030838Phasing Meter Tester
16kV Digital Phasing Tester KitCat. No. C4033402 (221⁄2 lb./10.2 kg.)
T4030856ElbowAdapter
TwoT4030857
BushingAdapters
C4030838Phasing Meter Tester
40kV Digital Phasing Tester KitCat. No. C4033403 (211⁄2 lb./9.7 kg.)
Hi-pot testing cannot be done with the 40kV unit.
Two H176016-ft. x 11⁄4"-dia. Epoxiglas® universal poles in P6436 Bag
T4030856ElbowAdapter
C4033369Digital Phasing Tester
C4033370Digital Phasing Tester
NOTICE: UseONLYtheExtensionResistorsspecifiedforeach DigitalPhasingTesteraslistedonthispage. ExtensionResistorsareNOTinterchangeablebetween 16kVand40kVDigitalPhasingTesters.
Two H176016-ft. x 11⁄4"-dia. Epoxiglas® universal poles in P6436 Bag
AccessoriesH18766S ShepherdHookProbe 1⁄4lb./0.1kg.
H18766 StraightProbe 1⁄8lb./0.1kg.
Extension Resistors for 16kV Digital Phasing TesterH18762 PairofExtensionResistors
forupto80kV(32"long)6lb./2.7kg.
H18764 PairofExtensionResistorsforupto48kV(21"long)
4lb./1.8kg.
P6242 Bagfor48kVResistors 1lb./0.5kg.
P6244 BagforH1876280kVResistors 11⁄4lb./0.6kg.
Extension Resistors for 40kV Digital Phasing TesterC4033371 PairofExtensionResistors
forupto80kV(21"long)4lb./1.8kg.
P6242 BagforC403337180kVResistors 1lb./0.5kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2456 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Digital Phasing Testersfor Transmission Circuits• Two models for up to 120 kV or 240 kVFeatures & Applications• Easilydeterminephaserelationships• Readapproximatevoltage(line-to-lineorline-to-
ground)ontransmissioncircuits• Featuretwohigh-impedancecomponents
encapsulatedinfiberglasspoles,eachwithanendfittingthreadedforinterchangeablehookprobes
• 22-ft.-longinsulatedflexiblecablefromvoltmeterstoresonreelonotherpole
• Twocompletekitsofferachoiceofvoltagerangesforspecificsystemapplications
• Eachkitincludesapairof1-1⁄2"-dia.insulatedhandlesforproperworkingclearances
• Individualitemslistedineachkit’sbillofmaterialsmaybeorderedseparatelybyreferencenumbersgiven
Large direct display with backlight and hold features
10 - 120 kVDigital Phasing Tester
40 - 240 kVDigital Phasing Tester
C403045996" Epoxiglas®
Handles
Phasing Meter Testerfor Transmission Phasing Testers (pages 2456-2457)
Ordering Information
PSE4033473Phasing Meter Tester
for Transmission Phasing Testers
Features & Applications• Allowslinepersonneltodetermine,inthefield,the
operatingconditionofCHANCEinstrumentsabove• Useseachinstrument’sownmetertodisplayits
operatingcondition• Testerplugsintojackoninstrument• Meterreadingsarenotedwhentester’sclipis
contactedtoeachofinstrument’stwoterminalsandtester’spolarityswitchisinbothofitspositions
• Instrumentisinproperworkingorderifallfourreadingsarewithintwounits
• Pullingplugfromjackautomaticallydisconnectstester’sbattery
• 9-voltbattery,furnished,usuallylastsoneyearandiseasilyreplaced
• Tester’sdurableandcompactfiberglasshousingwillwithstandabuseoffieldapplications
Catalog No. Description Weight
PSE4033473 PhasingMeterTesterwithleadsandbattery
1lb./0.5kg.
Catalog No. Description WeightPSC4033465 10-120kVPhasingTesterKit:
(1)InstructionManual(1)PSE4033454PhasingTester(64"long)(2)C4030459Handles(96")(1)P6218BagforHandles(108")(1)C4030460BagforTester(1)PSE40333473MeterTester
40lb./18.2kg.
221⁄2lb.
10lb.31⁄2lb.3lb.1lb.
PSC4033466 40-240kVPhasingTesterKit:(1)InstructionManual(1)PSE4033455PhasingTester(102"long)(2)C4030459Handles(96")(1)P6218BagforHandles(108")(1)C4030464BagforTester(1)PSE40333473MeterTester
61lb./27.7kg.
431⁄2lb.
10lb.31⁄2lb.3lb.1lb.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2457July 2018
C403045996" Epoxiglas®
Handles
Phasing Meter Testerfor Transmission Phasing Testers (pages 2456-2457)
Features & Applications• Allowslinepersonneltodetermine,inthefield,the
operatingconditionofCHANCEinstrumentsabove• Useseachinstrument’sownmetertodisplayits
operatingcondition• Testerplugsintojackoninstrument• Meterreadingsarenotedwhentester’sclipis
contactedtoeachofinstrument’stwoterminalsandtester’spolarityswitchisinbothofitspositions
• Instrumentisinproperworkingorderifallfourreadingsarewithintwounits
• Pullingplugfromjackautomaticallydisconnectstester’sbattery
• 9-voltbattery,furnished,usuallylastsoneyearandiseasilyreplaced
• Tester’sdurableandcompactfiberglasshousingwillwithstandabuseoffieldapplications
Three kits for Transmission CircuitsFeatures & Applications• Determinephaserelationships• Readapproximatevoltage(line-to-lineorline-to-
ground)ontransmissioncircuits• Featureshigh-impedancecomponentsencapsulatedin
fiberglasspoles,eachwithanendfittingthreadedforinterchangeablehookprobes
• 22'longinsulatedflexiblecablefromvoltmeterstoresonreelonotherpole
• Threecompletekitsofferachoiceofvoltagerangesforspecificsystemapplications.Eachkitincludesapairof1-1⁄4"-dia.insulatedhandlesforproperworkingclearances
• Individualitemslistedineachkit’sbillofmaterialsmaybeorderedseparatelybyreferencenumbersgiven
AnalogTransmission
Phasing Tester
Catalog No.
C4030457
C4030458
T4032781
Description
69-120kVPhasingTesterKit:(1)InstructionManual(1)E4030498Tester(62"long)(2)C4030459Handles(96")(1)P6218BagforHandles(108")(1)C4030460BagforTester
69-161kVPhasingTesterKit:(1)InstructionManual(1)E4030499Tester(75"long)(2)C4030459Handles(96")(1)P6218BagforHandles(108")(1)C4030464BagforTester
69-240kVPhasingTesterKit:(1)InstructionManual(1)E4032780Tester(98"long)(2)C4030459Handles(96")(1)P6218BagforHandles(108")(1)C4030464BagforTester
Weight
39lb./17.7kg.
221⁄2lb.10lb.31⁄2lb.3lb.
44lb./20kg.
271⁄2lb.10lb.31⁄2lb.3lb.
60lb./27.2kg.
431⁄2lb.10lb.31⁄2lb.3lb.
Ordering Information
PSE4033473
Analog Phasing Testers
Catalog No. Description Weight
PSE4033473 Toolwithleadsandbattery 1lb./0.5kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2458 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
D.C. Hi-Pot URD Test Adapters
Features & Applications• WorkwithCHANCEPhasingToolH1876(page2452)for
meteredreadout• Forquick,reliablefaultdetectiononunderground
cables• Twounitsareavailableforphase-to-phasesystem
voltagesupto16kVor35kV• ByconvertingACsourcevoltagetoarectifiedhalf-
wave,theseadapterspermittestingofcableswithapotentiallevelequaltopeaksourcevoltage
• Field-effectivemethodprovesespeciallybeneficialfor: oTestingnewcablebeforeinitialenergizing oTestingrepairedcablebeforere-energizing oTestingsuspectcablespansforfaults• Brassmalefittinginsidelargerendthreadsontothe
meterprobeofphasingtool• Fortestingandsubsequentdischarging,brassfemale
fittingatsmallerendacceptsCHANCEElbowAdaptersorBushingAdaptersfor15through35kV(page2455)
• Illustratedinstructionbookletisincluded• Unitscontainhigh-voltagerectifiersencapsulated
inCHANCEorange1-1⁄4"and1-1⁄2"dia.Epoxiglas®housings
Hi-PotAdaptersmeasureonly13"inlengthfor35kVunit,and10"for16kVunit,farright.
*Maximumphase-to-phasesystemvoltage.
EnergizedSwitch or
Transformer
Bushing Adapter
DC Hi-PotAdapter
Feed-ThruUniversal Sticks
Bushing Adapter Reel Stick of Phasing Tester
EnergizedSwitch or
Transformer
DisconnectBuriedPrimaryCable
Meter Stick of Phasing Tester
Catalog No. Description Weight, eachC4031762 *16kVHi-PotAdapter 1lb./0.5kg.C4031763 *35kVHi-PotAdapter 11⁄4lb./0.6kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2459July 2018
Phase Rotation TesterFeatures & Applications• Todeterminethecorrectphase-rotationrelationship,
thisportableinstrumentfeaturesconstructionsimilartoPhasingTesterH18761,page2452
• AnadditionalgroundingcircuitonthePhaseRotationTestersetsitapartforphaserotationtesting
• Testerconsistsoftwofiberglasspoleswithendfittingsthreadedforinterchangeableprobes
• Probefittingscouplewithahigh-impedancecomponentencasedineachpole
• 22ft.lengthofinsulatedcablestoresonreelaffixedtoonepoleandconnectstovoltmeteronotherpole
• Groundingterminalbelowthemeterpermitsconnectiontoaknowngroundforproperoperation
• Tocheckinstrumentbeforeandaftereachuse,atest-pointjackinfrontofmeteracceptstheplugfromPhasingMeterTesterC4030838,shownonpage2457
Application Range• AttachestoEpoxiglas®
UniversalPolesofproperlengthforvoltagebeingworked
• Meterdisplaysupto16kValone
• Canalsoreadcircuitsthrough80kVwiththethread-onExtensionResistors
Weight23lb./10.4kg.6lb./2.7kg.4lb./1.8kg.
13⁄4lb./0.7kg.1lb./0.5kg.1lb./0.5kg.
11⁄4lb./0.6kg.2lb./0.9kg.
DescriptionPhaseRotationTester,16kV,withCasePairofExtensionResistorsforthrough80kV,Length:43"PairofExtensionResistorsforthrough48kV,Length:25"UniversalPole,11⁄4"x6',TwoNeededBagforTwoUniversalPolesBagfor48kVExtensionResistorsBagfor80kVExtensionResistorsCarryingCaseOnlyforTester
Catalog No.H1879H18762H18764H17601P6436P6242P6244
H18763
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2460 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Wireless Phasing Set (WPS)Phasing Mode Range: 480V up to 765kVARVI Mode Range: Cap. Test Point up to 765kVFeatures & Applications• Dualmodeunit–WirelessPhasingSet(WPS)andfull
rangeAuto-RangingVoltageIndicator(ARVI)• WPSmodefordeterminingphaserelationship
betweentwoconductorswithsamenominalvoltage• ARVImodetodetermineapproximatevoltageclassof
energizedconductor• BrightLEDsandaudiblealarmindicatein-phaseor
out-of-phase(WPSmode)andvoltageclass(ARVImode)
• Foruseon50/60Hzoverheadandundergroundsystemswithproperadapters
• Forusewithhotsticksonly
Design Features• Wirelessmainandprobeunitshavearangeof
approximately300ft• Batterydrawerdoesnotrequireremovaloffront
panelforreplacementofbatteries• RequirestwoAAbatteriesforeachunit• WorkswithelbowandbushingadaptersforURD
applications
Operation• TouseintheARVImode,onlyturnonthemainunit
bydepressingthepowerbutton.ThemainwillgointoARVImodewhentheyellowARVImodeLEDturnssolid.
• TouseintheWPSmode,turnonboththemainandprobeunitsbydepressingthepowerbuttonsonbothunits.ThebluecommLEDswillturnsolidwhentheunitsarelinked.
Optional Field Tester• TheWPScanbefieldtestedinARVImodewiththe
PSC4033582VoltageIndicatorTester
Orange Bag Hard Case (sold separately)
Catalog No. Description Weight
PSC4032916 WirelessPhasingSetwithOrangeBag
10lb./4.5kg.
PSC4033926 WirelessPhasingSetwithHardCase
13lb./5.9kg.
PSC4033811 HardCaseOnly 6lb./2.7kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2461July 2018
Includes the tester unit, a shepherd hook probe, a straight probe, instruction manual and hard shell padded case.
Distribution / Transmission ARVI(Auto-Ranging Voltage Indicator)Cat. No. PSC4032915 (41⁄2 lb./2.0 kg.)
Full Range (600V – 500kV)Auto-Ranging Voltage Indicator (ARVI)
Bright display lights indicate voltage classThis smart new-generation instrument makes hot-linevoltage testing easier than ever. Its state-of-the-artelectronics eliminate the need for a selector switch.Its automatic-ranging function quickly displays theapproximate phase-to-phase voltage class.Itprovidesaneasy,reliablemeansfortheoperatortodetermineifalineis:a) De-energized,orb) Carrying less than normal system voltage from any
sourceorinducedvoltagefromanadjacentlivecircuit,or
c) Energizedatfullsystemvoltage.
Simple to operate, the tester attaches to an Epoxiglas®insulating universal hot stick of appropriate length tomaintainproperOSHAworkingclearances.Asinglepushbuttonactivatestheinstrument,thenasinglelightindicateseither Power On (by glowing solid) or Low Battery (byblinking).Withagoodbatterycondition,theinstrumentperformsaconfirmingself-testbyilluminatingeachofthe12indicatorlightsinserieswhileemittinganalternating audible signal.
Then the probe can be brought into contact withthe conductor. It automatically begins detecting atapproximately100Vandholdsthedisplayofoneofthesephase-to-phasevoltageclasses:600V,4kV,15kV,25kV,35kV,69kV,115kV,161kV,230kV,345kVor500kV.Theaudiblesignalbeginsasaslowbeepingthatbecomesfasterasthereadingisincreased.
When not in use, the unit’s energy-saving Sleep modeautomaticallyconservesthebattery.
Voltage Indicator Tester PSC4033582
Plug-in jack on Full-Range ARVI housing permits line personnel to quickly verify its operable
condition with Voltage Indicator Tester (Cat. No. PSC4033582) before and after each use.
MUST BE ORDERED AS A SEPARATE ITEM
Complies with OSHA 1910.269 to Test for Absence of Nominal Voltage• 600V to 500kV • For Overhead and URD Systems
Large easy-to-read display activates each red light, one at a time, beginning at the low end and finally holds on the light for the phase-to-phase voltage class detected.
Accessories
ThismodeladaptstobothoverheadlinesaswellasURD
circuitswith200and600Ampelbows, including those with and
without capacitance test-points. Inter-changeableprobesandadaptersjustthread
intotheARVIendfittingandtestpoint(T.P.)settingap-propriatetoeachapplication.Furnishedowner’smanualillustratesoperatingdetailsforallmodels.
...continuedonnextpage...
H18766S Shepherd Hook Probe 0.3 lb./0.1 kg.
H18766 Straight Probe 0.1 lb./0.1 kg.
T4030428 15kV only Bushing Adapter 0.5 lb./0.2 kg.
T4030856 15 - 35kV Elbow Adapter 1 lb./0.4 kg.
T4030857 15 - 35kV Bushing Adapter 1.6 lb./0.7 kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2462 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
URD Voltage Presence Testwith Bushing Adapter and your feed-thru device
This model is capable of these three test methods:
Full Range (600V – 500kV)Auto-Ranging Voltage Indicator (ARVI)
URD Capacitance Testwith Straight Probe on Elbows with Test Points
FPO
Overhead Voltage Presence Testwith Shepherd Hook Probe
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2463July 2018
DistributionAuto-Ranging Voltage Indicator (ARVI)
Large easy-to-read display activates each red light, one at a time, beginning at the low end and finally holds on the light for the phase-to-phase voltage class detected.
Includes the tester unit, a shepherd hook probe, instruction manual and hard shell padded case.
Basic ARVI for Overhead ApplicationsCatalog No. C4033374 (51⁄2 lb./2.5 kg.)
Complies with OSHA 1910.269 to Test for Absence of Nominal Voltage• 600V to 69kV • For Overhead & UndergroundBright Display Lights Indicate Voltage Class• Makeshot-linevoltagetestingeasierthanever• State-of-the-artelectronicseliminateneedforselector
switch• Automatic-rangingfunctionquicklydisplays
approximatephase-to-phasevoltageclass• Provideseasy,yetreliablemeansforoperatorto
determineifalineis: o De-energized,or o Carryinglessthannormalsystemvoltagefromany
sourceorinducedvoltagefromanadjacentlivecircuit,or
o Energizedatfullsystemvoltage• Simple-to-operatetesterattachestoanEpoxiglas®
insulatinguniversalhandleofappropriatelengthtomaintainproperOSHAworkingclearances
• Singlepushbuttonactivatestheinstrument,thenasinglelightindicateseitherPowerOn(byglowingsolid)orLowBattery(byblinking)
• Withgoodbatterycondition,instrumentperformsaconfirmingself-test
• Itdoesthisbyilluminatingeachofthesixindicatorlightsinserieswhileemittinganalternatingaudiblesignal
• Thentheprobecanbebroughtintocontactwiththeconductor
• Itautomaticallybeginsdetectingatapproximately480Voltsandholdsdisplayofoneofthesevoltageclasses:600V,4kV,15kV,25kV,35kVor69kVphase-to-phase
• Audiblesignalbeginsasaslowbeeping,becomingfasterasfinalreadingisdisplayed
• Whennotinuse,unit’senergy-savingSleepmodeautomaticallyconservesbattery
Overhead & Underground Capabilities• Foroverheadtesting,aShepherdHookprobeis
includedwiththeBasicARVI(Auto-RangingVoltageIndicator)
• Forundergroundtesting,ElbowAdapterT4030856and
ARVI Kitfor Overhead and Underground
Catalog No. T4033418 (161⁄4 lb./7.4 kg.)Includes the tester unit, shepherd hook probe, elbow adapter, bushing adapter, voltage indicator tester, instruction manual and hard shell padded case.
Bushing Adapter T4030857for 15, 25, 35kV
Elbow Adapter T4030856for 15, 25, 35kV
Voltage Indicator Tester C4033409
ARVIAuto-RangingVoltage Indicator
ARVIAuto-RangingVotage Indicator
Accessories
BushingAdapterT4030857areincluded• TheysimplythreadontotheARVIinthefieldtocheck
forvoltageatswitchbushingsorelbowsoncables,usingafeed-thrudevice
H18766S ShepherdHookProbe 1⁄4lb./0.1kg.
H18766 StraightProbe 1⁄8lb./0.1kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2464 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Includes the tester unit, a shepherd hook probe, instruction manual and hard shell padded case.
Transmission ARVI(Auto-Ranging Voltage Indicator)Cat. No. C4033375 (51⁄2 lb./2.5 kg.)
TransmissionAuto-Ranging Voltage Indicator (ARVI)
Bright Display Lights Indicate Voltage Class• Makeshot-linevoltagetestingeasierthanever• State-of-the-artelectronicseliminateneedforselector
switch• Automatic-rangingfunctionquicklydisplays
approximatephase-to-phasevoltageclass• Provideseasy,yetreliablemeansforoperatorto
determineifalineis: o De-energized,or o Carryinglessthannormalsystemvoltagefromany
sourceorinducedvoltagefromanadjacentlivecircuit,or
o Energizedatfullsystemvoltage• Simple-to-operatetesterattachestoanEpoxiglas®
insulatinguniversalhandleofappropriatelengthtomaintainproperOSHAworkingclearances
• Singlepushbuttonactivatestheinstrument,thenasinglelightindicateseitherPowerOn(byglowingsolid)orLowBattery(byblinking)
• Withgoodbatterycondition,instrumentperformsaconfirmingself-test
• Itdoesthisbyilluminatingeachofthesixindicatorlightsinserieswhileemittinganalternatingaudiblesignal
• Thentheprobecanbebroughtintocontactwiththeconductor
• Itautomaticallybeginsdetectingatapproximately69kVandholdsdisplayofoneofvoltageclasses:69kV,115kV,161kV,230kV,345kVor500kVphase-to-phase
Voltage Indicator Tester C4033431
Plug-in jack on Tester meter housing permits line personnel to quickly verify its operating
condition with a Voltage Indicator Tester (Cat. No. C4033431) before and after each use.
MUST BE ORDERED AS A SEPARATE ITEM
Complies with OSHA 1910.269 to Test for Absence of Nominal Voltage• 69kV to 500kV • For Overhead Conductors
Large easy-to-read display activates each red light, one at a time, beginning at the low end and finally holds on the light for the phase-to-phase voltage class detected.
Accessories
• Audiblesignalbeginsasaslowbeeping,becomingfasterasfinalreadingisdisplayed
• Whennotinuse,unit’senergy-savingSleepmodeautomaticallyconservesbattery
H18766S ShepherdHookProbe 1⁄4lb./0.1kg.
H18766 StraightProbe 1⁄8lb./0.1kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2465July 2018
Light Switch
Easier-To-Read, illuminated Dial • Thelighted-dialoptionsetsthisunitapartfromstandard
featuresonMulti-RangeVoltageDetector(MRVD)C4030979,shownonnextpage
• Along-lifebulb,poweredbyincludedinternalbattery,givesaglowtothemeterfacesoscaleiseasytoreadinmostconditions
• Toconservethebattery,aspecialswitchlocksthelightoffwhennotinuse
• Spring-loadedtogglemustbepulleduptomoveitoverthestopbetweenitsonandoffpositions
• Thishelpskeepswitchfrombeingflippedonaccidentallywhileunitisnotinuse
Standard Features • Confirmsalineisde-energizedpriortoperforming
maintenance• Afieldintensitymeter,itiscalibratedtoread
approximatephase-to-phasevoltagewhenconnectedtoanyphaseconductor
• Respondstomagnitudeoffieldgradientbetweenitsendprobeandfloatingelectrode(attheuniversalhotstick-attachmentfitting)
• Iftheuniversalfittingisclosetoaground,anotherphaseoranothervoltagesource,readingshouldbehigh
• Ifit’sclosetoajumperorequipmentofthesamephase,thereadingshouldbelow
• Givesmeteredreadoutcapableofdistinguishingactuallinevoltagefromstaticorfeedoverfromanadjacentline
• Numericalreadingscanbecomparedwithnumericalratherthansubjectivejudgmentsassociatedwith“fuzzsticking”or“glow-detecting”• Sinceitisnotavoltmeter,nospecificaccuracyisclaimed
bythemanufacturerorcanbeassumedbytheuser
Operation • Mustbemountedonproperlengthhotstickforthe
voltageclassinvolved• Completeinstructionsarefurnishedwitheasy,illustrated
step-by-stepprocedures• Internalcircuitandpushbuttonpermitcheckbefore
andaftereachusetoconfirmoperationalconditionofinstrumentandbattery
Includes:• Straight probe for URD elbows with test points• Hook probe for overhead uses• Instructions and storage case
OverheadVoltage-PresenceTest with HookProbe
Self-testButton
▲
Lighted-dial model for systems through 40 kV
URD Voltage-PresenceTest on elbows withTest Points can beperformed with Straight Probe when selector is set at TP
Multi-Range Voltage Detector
Catalog No. Scale Weight
T4033228 1-40kV 51⁄2lb./2.5kg.
AccessoriesH18766S ShepherdHookProbe 1⁄4lb./0.1kg.
H18766 StraightProbe 1⁄8lb./0.1kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2466 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
*FortestingURDelbowswithtestpoints,onlymodelC4030979onthispageincludesstraightprobeand“TP”settingonselectorswitch(aswellashookprobeforoverheaduses).For other URD models and Accessories, see next page.
Ordering Information
Distribution and TransmissionMulti-Range Voltage Detectors
Catalog No.C4030979*C4031029C4031140
Scales1-40kV
16-161kV69-600kV
Weight51⁄2lb./2.5kg.51⁄2lb./2.5kg.51⁄2lb./2.5kg.
Multi-Range Voltage Detectorsfor Overhead Systems to 600 kV and URD Elbow Test Points*
Overhead Voltage-Presence Test can be performed by all models.
Switch on C4030979* includes Test Point.
Self-testButton
▲
C4031029 or C4031140
C4030979*
URD Voltage-PresenceTest on Elbows withTest Points can beperformed only byModel C4030979* setat TP and fitted withits Straight Probe.
Design Features • Confirmsalineisde-energizedpriortoperforming
maintenance• Afieldintensitymeter,itiscalibratedtoread
approximatephase-to-phasevoltagewhenconnectedtoanyphaseconductor
• Respondstomagnitudeoffieldgradientbetweenitsendprobeandfloatingelectrode(attheuniversalhotstick-attachmentfitting)
• Iftheuniversalfittingisclosetoaground,anotherphaseoranothervoltagesource,readingshouldbehigh
• Ifit’sclosetoajumperorequipmentofthesamephase,thereadingshouldbelow
• Givesmeteredreadoutcapableofdistinguishingactuallinevoltagefromstaticorfeedoverfromanadjacentline
• Numericalreadingscanbecomparedwithnumericalratherthansubjectivejudgmentsassociatedwith“fuzzsticking”or“glow-detecting”• Sinceitisnotavoltmeter,nospecificaccuracyisclaimed
bythemanufacturerorcanbeassumedbytheuser
Operation • Mustbemountedonproperlengthhotstickforthe
voltageclassinvolved• Completeinstructionsarefurnishedwitheasy,illustrated
step-by-stepprocedures• Internalcircuitandpushbuttonpermitcheckbefore
andaftereachusetoconfirmoperationalconditionofinstrumentandbattery
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2467July 2018
T4032271for Overhead and for URD Loadbreak Elbows
Catalog No.T4032271
DescriptionMRVD,Hook&StraightProbes,Elbows&BushingAdapters,Case
Weight6lb./2.7kg.
Ordering Information
5-15-25-40 kV Multi-Range Voltage Detectorwith TP Setting for Test Point on URD Elbows
*Elbow Adapter also furnished to complete testwhen not using a feed-thru bushing device.
URD Voltage Presence Test URD Voltage Presence Test
andyour feed-thru device*
withBushingAdapter
withStraightProbe
on ElbowswithTest Points
Features & Applications• Testbothoverheadandundergrounddistribution
systems• Forsystemsinvoltageclassesfrom5through40kV• Provideeasy,yetreliablemeansforoperatorto
determineifalineis: o De-energized,or o Carryinglessthannormalsystemvoltagefromany
sourceorinducedvoltagefromanadjacentlivecircuit,or
o Energizedatfullsystemvoltage• AdapttobothoverheadlinesaswellasURDcircuits
with200and600Amploadbreakelbowsincludingthosewithandwithoutcapacitivetestpoints
• InterchangeableprobesandadaptersthreadintotheMRVDendfittingandtheselectorswitchdialstothevoltagerangeortestpoint(T.P.)settingappropriatetoeachapplication
• Furnishedowner’smanualillustratesoperatingdetailsforallmodels.
Thismodeliscapableofthesethreetests:
Multi-Range Voltage Detectorsfor Overhead & URD Systems to 40 kV
Accessories
Self-testButton
▲
Overhead Test
H18766S ShepherdHookProbe 1⁄4lb./0.1kg.
H18766 StraightProbe 1⁄8lb./0.1kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2468 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Features & Applications• Visibleandaudiblevoltageindicatorwith
rangefromCapacitiveTestPointupto80kVPhase-to-Phase
• BluetoothConnectivitytoviewMRVIdisplayliveonamobiledevice
• Mobileappdisplaysthemeterfaceandapproximatephase-to-phaseandphase-to-groundvoltages
• Large,easy-to-readdialfaceandbrightlyilluminatedpointerindicatetheapproximatephase-to-phaseandphase-to-groundvoltage
• Canbeusedonoverheadandundergroundlineswithproperadapters
Design Features• Newbatterydrawerdoesnotrequireremoval
offrontpanelforreplacementofbatteries• RequiresfourAAbatteries• Comeswithstoragebagdesignedwith
snaphookforsuspendingfrombeltorinstorage
• Lightweight• Workswithelbowandbushingadaptersfor
URDapplications
Operation• Toturnonthemeter,pressthepowerswitch
untilthemeterlightsturnonandaudibletoneisheard
• Theneedlewillfullydeflecttoshowtheconditionofthebatteries
• TheneedlewillthengobacktothezeroandthesenselightwillblinkindicatingtheMRVIisreadytotakeareading
• Holdmodecanalsobeselectedbydepressingthepowerbuttontwiceinquicksuccession
• OptionalmobileappcanbedownloadedfromtheGooglePlayorAppleiTunesstore
Optional Field Tester• Theproximityvoltageindicatorcanbefield
testedwiththeVoltageIndicatorTesterPSC4033582
Multi-Range Voltage Indicator (MRVI)Capacitive Test Point up to 80kV phase-to-phase – Bluetooth connectivity for mobile device
Catalog No. Application WeightPSC4033710 Multi-RangeVoltage
IndicatorandBag1.3lb./0.6kg.
PSC4033925 Multi-RangeVoltageIndicatorandHardCase
1.3lb./0.6kg.
Snaphook on each bag• Forsuspendingfrombeltorinstorage• Leatherreinforcedtabisstitchedtothebackofeachbag
Mobile Device Display
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2469July 2018
Super Tester Voltage Detector• Dual Range • Audible & Visible IndicatorsFeatures & Applications• Lightsblinkandalarmsoundswhenplacedinelectrostaticfield
abovetriggerthreshold• Fiveflashingredlightsalerttheoperator• High-pitchedtonesalsosignalnearbypersonnelofpresent
voltagethatcouldbedangerouswhenapplyingtemporarygroundsorperformingmaintenance
• Canbeusedtocheckoverheadlines,insubstationsandaroundswitchgear
• Simplyslipsovertheheadofastandard1-1⁄4"-diameterdisconnectstick
• MaybeusedonaCHANCEGrip-Allclampstick,universal,telescopingorpositive-griphotlinestickfittedwithaspecialadapter(seetablebelow)
Design Features• Handythree-wayswitchpermitsselectionofeitherthe1-100kV
orthe100-800kVrangeforcircuitbeingtested• Turnsoffunittosavethebatterywhennotinuse• 9-Voltalkalinebatteryreadilyinstallsbyremovingtwoknurl-head
screwsandslidingofftheinstrumentcover• Testbuttonchecksboththebatteryandthetester• Depressingbuttonactivatessignalcircuits,soundingthetoneand
lightingthealarmlampsifthebatteryisgoodandunitoperable• Comeswithinstructionspackedinlined,reinforcedcasewith
carryinghandle
Operation• Turnontesterwithselectorswitchforvoltagerangerequired• Checkbatteryandunitbypushing“Test”button• Iftonevolumeisnotclearorindicatorlightsarenotbright,
replacebatteryandrecheck• Mounttesteronproperhotlinetool• Formaximum-strengthsignals,placethetesterwithinfollowing
minimumproximitytothecircuitbeingtested
Phase-to-Phase versus Response Distance
kV (1 - 100kV Range) (100 - 800kV Range)
Distance - inches Distance - inches
2.0….................0
13.8….................4
25.0…...............12
34.5…...............19…...............…..............1
69…..................39…...............….............. 3
115…........................................................ 7
161…......................................................10
230…......................................................20
345…..................................................... 26
525…..................................................... 44WARNING: Instrument damaged by touching 33kV or higher.
Note: Super Tester will not detect any voltage on cable with metallic sheath or semiconductive coating. Super Tester does not discriminate between induced and line voltage types. Device signals in the presence of either and the operator must determine which type before following utility safety working practices for engaging energized conductors.
Ordering InformationCatalog No.
H1990ST
M445598(Catalog
Section2100)
Description
SuperTester,battery,plasticcase
SuperTesterAdapterforGrip-All,Universal,TelescopingorPositive-Griphotlinetools
Weight
43⁄4lb./2.1kg.
5oz./0.1kg.
M445598 AdapterfitsintoSuperTestereitherwaysoyoucanuseitonaGrip-AllclampstickoronasplinedfittingofUniver-sal,TelescopingorPositive-Griphotlinesticks.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2470 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Features & Applications• Brightdisplaylightsandaudiblealarm
indicatevoltageclasswithoutneedtodirectlycontacttheconductor
• Theclassdisplayedistheapproximatephase-to-phasevoltageclass
• Usedtodetermineifpowerlinesareatratedvoltage,haveinducedvoltageorarede-energized
• Designedasanon-contactVoltageIndicator• Mustbeusedwithproperlyselecteduniversal
hotstick,evenwithrubbergloves• Designedtobeheld6to18inchesaway
fromconductorbeingtestedforpresenceofvoltage
• Advancedfeatureallowsusertotemporarilydisablerangeindicationsforvoltagesbelowtheuserselectedrange
Design Features• Newbatterydrawerdoesnotrequireremoval
offrontpanelforreplacementofbatteries• RequirestwoAAbatteries• Comeswithstoragebagdesignedwith
snaphookforsuspendingfrombeltorinstorage
• Lightweight,1.25lbsversusthe4.75lbsoftheSuperTester
Operation• Toturnonthemeter,pressthepowerswitch
untiltheaudibletoneisheard• EachLEDwilllightupindividuallyfromthe
lowesttohighestandthenthealarm• Bringtheindicatorwithin6to18inchesof
thelinetobemeasured• Below480volts,theindicatormayneedtobe
6inchesorlessawayfromtheline• Onceanelectricalfieldisdetected,therange
indicationswillincreaseasyouapproachtheconductor
• Asthevoltagefieldintensityincreases,theProximity“SENSE”LED,RangeLEDandaudiblealarmwillflashandbeepfaster
Optional Field Tester• Theproximityvoltageindicatorcanbefield
testedwiththeVoltageIndicatorTesterPSC4033582
Proximity Voltage Indicator (PVI)600V to 500kV - Audible & Visible Indicators
Catalog No. Application Weight
PSC4033737 ProximityVoltageIndicatorandBag
1.3lb./0.6kg.
Snaphook on each bag• Forsuspendingfrombeltorinstorage• Leatherreinforcedtabisstitchedtothebackofeachbag
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2471July 2018
Transmission TesterC4032299
*Carryingcaseweighsadditional101⁄4lb.(4.6kg.)
Catalog No.C4032298C4032299
System ApplicationsDistribution(thru35kV)Transmission(44thru500kV)
Weight4lb./1.8kg.5lb./2.3kg.
Energized Insulator Testers(each includes instrument, two straight probes,operating instructions and metal carrying case)
Plug-injackonInsulatorTestermeterhousingpermitslinepersonneltoquicklyverifyitsoperableconditionwithaPhasingVoltmeterTester(Cat.No.C4030838)beforeandaftereachuse.
for Distribution and Transmission SystemsOperation• Sensitivevoltmetermeasuresdifferenceinpotential
acrosseachinsulatorinasuspectstring• Comparativereadingsfromsatisfactorystringsinsame
operatingsituationquicklyindicatethestateofeveryinsulatorinthestringbeingtested
• Meterplacesminimalloadonthephaseasitrequiresonlyasmallleakagecurrenttomakeareading
• Twostraightsteelprobesthreadedintothetesterforkssimplycontactthemetalfittingsonbothendsofeachinsulatoratthesametime
• Mountedona1-1⁄4"-dia.Epoxiglas®polewithauniversalfitting
• Beforeeachusethetestershouldbeattachedtotheproperlengthhotstickforthesystemvoltageinvolved
• Distributionmodel’sscalereadsupto11kV• Transmissionmodel’sscalereadsamaximumof16kV
Applications• Withoutinterruptingservice,oneofthesetesters
quicklycanchecktheconditionofeachinsulatorinastring
• Greatlyreducesmaintenancecosts• Onlyinsulatorsidentifiedasdamagedrequire
replacements• Noneedtochangeentirestrings• Availableintwomodels• Testersservespecificapplications: o Deadendinsulatorsondistributionsystemsthrough
35kV o Suspensioninsulatorson44kVthrough500kV
transmissionsystems
Energized Insulator Testers
Distribution TesterC4032298
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2472 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Operation• Measureselectricalintegrityofpolymer
insulator• Comparesdatafromknowngoodinsulatoror
fromcalibrationsamplesprovided• Canbeusedonenergizedlineorde-
energized• Rechargeablebattery• Selfcontainedpowersupply.Doesnotrelyon
E-fieldtooperate.• Mustbeusedwithappropriatelength
Epoxiglas®polewithuniversalfitting• EasytointerpretGo/NoGolightsandaudible
tones• Datacanbeviewedanddownloadedto
Wi-Fienableddevice• Adjustableprobespacingtofitmost
suspensioninsulators• Ruggedcarryingcase
Applications• Canbeusedtocollectdataonenergizedline
withoutinterruptingservice• Usetotestinsulatorsbeforeinstallationfor
addedsecurity• Usedontransmissionsuspensioninsulators
69kVandaboveupto1.8”indiameter
Polymer Insulator TesterFor Transmission Suspension Insulators
Blue Probe Engaged Power
SwitchBattery Status
Blue Probe Engaged
Green Result Pass
Red Result Fail
Amber Warning/Busy
White Ready/ Power On
Calibration Indicators
Kitincludes;Tester,Batterycharger,Adaptercables,Calibrationsamples,HolderandUsersManual
Catalog No. Application Weight
PSC4033679 TransmissionSuspension69kVthru500kV
4.2lb./1.9kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2473July 2018
C4031369for 0 - 10 kV
To check tester’s condition before and after each use, test-point jack in front of meter accepts plug-in lead of Voltmeter Tester (see page 2453).
C4031367
Features & Applications• PortabledevicecheckstheACvoltageson
UndergroundDistributioncircuitsthrough20kV• Determinesapproximateline-to-groundvoltageofthe
circuits• Basicinstrument,C4031369,readsvoltagesupto10kV
onmeter• Resistanceunitsareencapsulatedinanepoxy
compoundtoprotectagainstmechanicaldamage• Preventsmoisturepenetrationoraccumulationaround
resistors• Nocalibrationisrequired–toolispresetatthefactory• Extensionresistorisprovidedforvoltagesabove10kV
phase-to-ground.Thisincreasesvoltagerangeto20kVphase-to-ground.
• Donotusemorethanoneextensionresistorelementpertool
• Groundconnectionismadetoastudonthestickbelowthemeterhousing
• ThisstudMUSTbeelectricallyconnectedtoagoodgroundsource
• BeforetheVoltageTesterisusedtotestelbowsorbushingsondeadfrontURDequipment,properadaptermustbeattachedtotool
• ElbowmustbecontrolledorrestrainedwithaninsulatedhotstickwhileusingVoltageTestertocheckelbows
• Elbowmustbeproperlyparkedwhenbushingisbeingchecked
Voltage Tester for Underground Transformers
BushingAdapter
T4030857
ElbowAdapterT4030856
Adapters for 15, 25 and 35 kV only
Units Assembledfor 20 kV Testing
Adapters for 15 kV only
BushingAdapter
T4030428
ElbowAdapterT4030602
Catalog No. DescriptionC4031367 CompleteVoltageTesterfor20kVØ-G
includesTester,ExtensionResistor,CaseandInstructionBooklet
C4031368 1ExtensionResistorC4031369 VoltageIndicator10kVØ-GwithCase
andInstructionBookletT4030602 ElbowAdapterfor8.3/15kVonlyT4030428 BushingAdapterfor8.3/15kVonlyT4030856 ElbowAdapterfor15,25&35kVT4030857 BushingAdapterfor15,25&35kVC4030838 ToolwithLeadsandBattery
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2474 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Features & Applications• AllowslinemantodeterminewhetherURDcableis
energizedorde-energized• Amplifierisdesignedtogiveameterreading• ThisoccurswhensmallACvoltagebetweenthesemi-
conductivesheathandtheconcentricneutraloftheenergizedURDcableisappliedtotestprobe
• Amplifierishousedinaruggedthermoplasticcase
• Self-testcontactpointislocatedontopofamplifierhousing
• Checkmeteroperationandbatteryconditionbytouchingtestprobetotestpoint
Dielectric Compound No. 7
DielectricCompoundNo.7,asiliconebasematerial,ismadeforusewithloadbreakdisconnectsandotherelectricalconnectingandterminatingdevices.
Cat. No. C4170287..................................... 2 oz. Tube
DescriptionURDCableSensor,twoleads,twohoseclamps,two9-voltbatteriesandinstructions
Weight5lb./2.3kg.
Catalog No.C4030803
• Sensorchecksenergizedconditiononconcentric-neutralcablebelowanelbowwithouttestpoints(asabove)
• Atcablemid-span(left),hoseclampsbridgeallstrandsofconcentricneutralatthetestlocation
• Sensor’sneutralleadclipstooneofthehoseclamps• Tiponprobeleadcontactssemi-conductivecable
sheathtotestvoltage
Energized Cable Sensor
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2475July 2018
Self-Contained, Portable Convenience• Usedtocheckresistanceinprotectivegroundingsets• 120VACand230VACmodelsavailable• AppliesDirectCurrentacrossthetestspecimen• Seven-minutevideo,includedwitheachunit,shows
howtousetester• Instructionmanualincludesproceduredetails• Allcomponentsstoreintester’sintegralcarryingcase
Protective-Grounding-Set Tester• Meets ASTM Standard F 2249 • Offers easy, accurate diagnostics
Troubleshooting Mode • Ifagroundsetdoesnotpassinitialtest,Testercanhelp
isolateproblems• High-resistancesourcecanoftenberemediedby
simplerepairstocableset• Retestingthencanquicklyverifytheeffectsofrepairs• Fortroubleshootingmode,testprobesarefurnishedto
plugintotheTester• Aswitchactivatestheminsteadofball-studterminals• Probesareusedtotestacrosseachcontactinterfacein
groundset• Resultsdisplayinmilliohms,justasinthefirsttest
mode
Optional Terminals For Special Ground Sets • Standardball-studterminalsacceptmosttypesof
groundclamps,includingCHANCEball-socketclamps.• Totestspecial-applicationgroundingsetsfor
underground-distributiontransformersorswitchgear,twooptionaladaptersshownonnextpageareavailableasseparateitems
Simple, One-Button Testing • Digitaldisplayshowstheresistancemeasuredin
milliohm• Comparemeasuredresistanceagainsttheacceptable
resistancelevelsspecifiedinASTMF2249• Resistancedisplayedwith±1%accuracy,from1micro-
ohmto6.5ohms
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2476 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Features & Applications• Quicklyandaccuratelyfigurespole,tree,orbuilding
heightsorconductorclearance• Easytooperate–onlytakeafewminutestolearn• Diagramshowshowitworks• SightpointAandmovebackwardorforwarduntilthe
bubblecentersonthehairline,whichispointC• MeasuredistancefromCtoDandadddistanceBCto
findcorrectheight• Leathercase(2-1⁄4"x4-1⁄4")hasbeltloop
CHANCE Teleheight
Optional Elbow Adapter C4033449 (15 & 25kV) for testing temporary grounding sets fitted with a grounding elbow. PSC4032947, 35kV, Elbow Adapter.
Optional Straight Stud Terminal T4033159 for testing grounded-parking-stand temporary grounding sets.
CompleteProtective Ground-SetTesterCatalog No.C4033220.
Optional Adapters:
Included with eachProtective-Grounding-Set Tester:• Self-containedcarrycase• 2ball-studterminals • DVDdemonstrationvideo • 2troubleshootingprobes• Self-testcable
Protective-Grounding-Set Tester (continued)
• For easy, accurate diagnostics• Meets ASTM Standard F 2249
T4033159 StraightStudTerminalfor15and25kV
3⁄4lb./0.3kg.
C4033449 15/25kVElbowAdapterfor.50"Probe
1lb./0.5kg.
PSC4032947 35kVElbowAdapterfor.50"Probe
11/4lb./0.6kg.
PSC4033796 35kVElbowAdapterfor.75"Probe
11/4lb./0.6kg.
Catalog No. Description WeightC4033220 115/120-VoltProtective
Ground-SetTester17lb./7.7kg.
PSC4033220003 230-VoltProtectiveGround-SetTester
17lb./7.7kg.
Catalog No. Description WeightCW TeleheightComplete
w/LeatherCase11/4lb./0.6kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2477July 2018
LoadLooker Ammeter• Models for Distribution, Transmission and Substation uses
• Hold feature for easy hotstick use
NarrowJaw
WideJaw
...continuedonnextpage...
User-Friendly Electronic-Loop Design• Electronicallyclosesloop• Nomoremanipulatingahingedorclamp-type
inductivepick-up• UniqueU-shapejawsensesamperagepresentbetween
tines• Open-enddesignforcheckingcomponentloadsnot
accessiblebyotherhot-lineammeters
Live-Line-Ready Hotstick Mount• Standardfittingmountsonyourinsulatedhotsticks• Fitsthesameasanyotheruniversaltool• Yourhot-linecrewscanbeginusingitimmediately
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2478 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Catalog No.
MEAMP11RW
MEAMP21RW
MEAMP32RN
MEAMP32RN2
Weight
3.1lb./1.4kg.
3.1lb./1.4kg.
3.1lb./1.4kg.
3.1lb./1.4kg.
Max. Voltage (Ø-Ø)
Upto69kV
Upto400kV
Upto500kV
Upto500kV
Max. Current
Upto2,000amps
Upto2,000amps
Upto5,000amps
Upto5,000amps
Reading Type
TrueRMS
TrueRMS
TrueRMS
TrueRMS
Jaw Size
3.86"
3.86"
2.50"
2.50"
Replacement CaseCatalog No.
C4002561
Description
HardCaseforLoadLookerAmmeter
Weight
2.5lb./1.1kg.
LoadLooker Ammeter
General SpecificationsLCD 31⁄2-digitdisplayof Amps,Hold,LowBattery
Battery 9voltalkaline(included)
Accuracy±1%+2Digits
Frequency50or60Hertz
Operating Temperature-30°to60°C(-22°to140°F)
Display RangeAutomaticRanging:
0-99.9Amperes,in0.1-Ampincrements. 100-1999Amperes,in1.0-Ampincrements. 2000-5000Amperes,in0.1kAAmpincrements.Operators Manual and Caseincluded
Rugged, Application-Specific Design• Materialsandconstructionaredesignedforfield-
conditionrigors• Typicalapplicationsinclude: o Identifyingloadimbalances oVerifyingaccuracyofcurrenttransformers oDeterminingloadtoselectproperlysizedjumpers oMeasuringloadbeforeopeningswitches
Simple Push button Operation, Direct-Reading Accuracy• PushitoncetoturnonLoadLooker• PushitasecondtimeandLoadLookerwilldisplaythe
wordHOLD• Willcontinuetodisplaythenextreadingit“sees”until
youpushthebuttontoclear• Thisletsyoubringitdownfromthelinetoeyelevelto
readit• Afterfiveidleminutes,unitwillturnitselfoff• Youcanalsomanuallyturnitoffbykeepingthebutton
depressedforfiveseconds• Operator’sManualandstoragecaseareincluded
Wide Jawwith
Hard Case
Narrow Jawwith
Soft Case
50 Hertz unit, Case and Operators Manual
Ordering Information60 Hertz unit, Case and Operators Manual
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2479July 2018
Controls & Meter for All Requirements• Simpletooperate,portableunit• Makeseasyworkoftestinginsulatedlive-linetools• Wetanddrymodesselectedbyatoggleswitch• FollowsproceduresspecifiedbyASTM,IEEEandOSHA• Graduatedmetergivesprecisereadoutofeachtool’s
leakagecurrent
Portable Operating Ease• Fortestinganylengthfiberglass-reinforcedplastic
(FRP)hotstickupto3”india.•Forspotchecksatfield
jobsitesorperiodicdiagnosticsinworkshop
•Full-scaletestsetupsforbothWet(75kV-per-foot)andDry(100kV-per-foot)
•Compact,self-containeduniteasilycarriedandoperatedbyoneperson
•InSetupprocedurebeforeeachuse,azeroingknobisusedtosetmetertozerowithoutatoolinthetester
•FurnishedCheckBarservesasself-checktoensuretesterisfunctional
• Includedvideodemonstrates“how-to”basicsforSetup,DryandWettests
• OwnersManualmustbereadandunderstoodbeforeoperatingtester
Catalog No.C4033178C4033179
Wet/Dry Hot Stick Tester115-voltmodel*230-voltmodel
Weight20lb./9.0kg.20lb./9.0kg.
Included with each Tester: • Check bar • Owners operating instruction manual • Demonstration video • Carrying case
Ordering Information
Quantitative Test Results• Whenplacedontool,displaysanyincreaseinleakage
currentduetohotstick• Givesimmediateindicationofstick’strueleakage
condition,independentofstraycurrents(throughtheair,internaltotesters,etc.)zeroedoutinadvance
• Detectsleakagecurrentsduetosurfacecontamination,internalmoistureandsuchinternalconductivematerialsascarbontracks
Wet/Dry Hot Stick Testerfor easy, portable compliance with industry standards
*Power-sourcecorddoesnotincludeplugon230-voltmodel
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2480 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Ladder Monitor Kitfor EHV Microamp Measurement on Barehand Equipment
Features & Applications• UsedwithEHVBarehandmaintenancetodetect
microampleakageonaladder• Meterisconnectedtoladderandtakesreadingswhen
ladderisincontactwithconductor• Recommendedthatreadingsbetakenperiodicallyto
ensureoptimalworkingconditionswhichcouldbealteredbychangeinatmosphere
• Kitincludes: o 200micro-ampscalemicroammeter o Threeclampstoeffectuseonathree-railladder o Cablewithclipsandadaptertoestablishcontact o Brackettogroundandholdmeteronstructure o Twodrycellbatteries o Instructiondrawingsforfieldassembly o Operatinginstructions
CHANCE SentinelLeakage-Current Monitor• Alertsutility-lineworkersofovercurrentconditions• Forsuchaerialdevicesasinsulatedladdersandtruck
booms• Soundsanalarmifleakagecurrentreachesapre-set
level• Leakagesettingadjustsfrom1to1,000microamperes
inresolutionincrementsof0.1microamp• Audiblewarningeliminatesneedtowatchtheactual
currentlevel,continuouslydisplayedondigitalLCDscreen
• Alarmsoundsimmediatelyuponovercurrentandcontinuesuntiltheconditioniscorrected
• Instrumentpaneljackacceptsastandard1⁄4"two-conductorphoneplugtoalsotriggeratruckhornorotherexternalalarm
• Paneltestterminalpermitsasimplecontinuitycheckofthemonitorleadspriortoeachoperation
• Beforeuse,instrumentautomaticallyperformsarapidelectronicself-test
• Simpleoperatingstepsareprintedoninsidelidpanel• Detailedinstructionsheetincluded
• Kitincludesonecoaxialcableandbattery,twojumpersandthreehoseclampsforconnectionstotwo-orthree-railladders
• Bracketsonboxsecuretoanearth-groundedstructureupto5⁄8"thicksuchasatransmissiontower
Catalog No. Description Weight
C4020288 LadderMonitorKit 7.5lb./3.4kg.
Catalog No. Description Weight
C4070025 CHANCESentinelKit 9lb./4.1kg.
Inst
rum
en
ts a
nd
Me
ters
– 2
45
0
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
Page 2481July 2018
Truck Boom Leakage-Current Monitor
Mounting studs on steel box bond directly to truck body.
• Mountsontruckbodyandhardwiresintotruck’s12-Voltsystem,whicheliminatesbatterychangeout
• Soundsanalarmifleakagecurrentreachesapre-setlevel
• Alertsutility-lineworkersofovercurrentconditionsontruckbooms
• Leakagesettingadjustsfrom1to1,000microamperesinresolutionincrementsof0.1microamp
• Audiblewarningeliminatesneedtowatchtheactualcurrentlevel,continuouslydisplayedondigitalLCDscreen
• Alarmsoundsimmediatelyuponovercurrentandcontinuesuntiltheconditioniscorrected
• Instrumentpaneljackacceptsastandard1⁄4"two-conductorphoneplugtoalsotriggeratruckhornorotherexternalalarm
• Paneltestterminalpermitsasimplecontinuitycheckofthemonitorleadspriortoeachoperation
• Beforeuse,instrumentautomaticallyperformsarapidelectronicself-test
• Simpleoperatingstepsareprintedontheinsidelidpanel
• Detailedinstructionsheetincluded
Catalog No. Decription Weight
T4070327 BoomMonitorKit(12Volt)
14lb./6.4kg.
Instru
me
nts a
nd
Me
ters – 2
45
0
Page 2482 July 2018
Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com
NEVER COMPROMISE™
www.hubbellpowersystems.com
Catalog2450
• 210 N. Allen St. • Centralia, MO 65240 • (573) 682-5521
NOTE:Hubbellhasapolicyofcontinuousproductimprovement.Pleasevisithubbellpowersystems.comtoconfirmcurrentdesignspecifications.©Copyright2018HubbellIncorporated
NOTICE:ForthelatestrevisionofourCatalogandLiterature,clickhereorvisitourwebsite:www.hubbellpowersystems.com
JULY2018