BYELAWS to be followed for the institutional buildingOJASis referred from the Local Planning
Area regulations of the Tiruchirappalli corporation
Variation to the Master Plan for Tiruchirappalli Local Planning Area
[G.O.Ms. No. 130, Housing and Urban Development (UD4-1), 14th June 2010.]
No. II(2)/HOU/379/2010.In exercise of powers conferred by sub-section (4) of section 32 of the
Tamil Nadu Town and Country Planning Act, 1971 (Tamil Nadu Act 35 of 1972), the Governor of
Tamil Nadu hereby makes the following variation to the master plan for Tiruchirappalli Local
Planning Area approved under the said Act and published with the Housing and Urban
Development Department Notification No.II(2)/HOU/453/2009 at page 319 of Part IISection 2 of
the Tamil Nadu Government Gazette, dated the 2nd September 2009.
PLANNING PARAMETERS:
Minimum road width9m
Maximum height of the building15m or G+3 or Stilt + 4 floors
Maximum floor space index (FSI)1.5
Maximum plot coverage60%
Front set back
o Min 3m; Up to 18m3m; 18m to 24m4.5m. More than 24m & NH & SH7m.
Side set back - 3m. or 1/4th height whichever is higher
Rear set back - 3m. or 1/4th height whichever is higher
Open space reservationas per Schedule 1
Parking spaceas per Schedule 2
Minimum width of corridorInstitutional buildingschools and colleges2.0meters
Special regulations for physically disabledSchedule 4
Rain water conservationSchedule 5
Vehicular ramp in setback spaces around building blocks may be permitted subject to the
condition that the clearance of the proposed ramp from the property boundary/street
alignment shall be minimum 1.5 meters and a clear motor able driveway of minimum 3.5
meters in width is available around the building block.
Parking standards: Educational buildings:
Floor area less than 100 sq.mnil
Floor area above 100sq.m but less than 1000sq.m one car space for every 200sq.m of
floor area.
7/24/2019 HSS Assignment
3/12
For every additional 100 sq.m of floor area or part thereof over 1000sq.mone car space.
Dimensions:
o The dimension of parking stall shall be 5.0m x 2.5m with a minimum which width of
driveway of 3.5m for one way movement and 7.2m width for two way movement.
In the case of ware house and go downs and industries the dimension of parkingstall shall be 10m x 3.75m with a minimum width of driveway of 3.75m. The
number of car spaces required will be calculated on 75% of the total floor area of
the building.
Radius: Minimum inside radius of lane 4.5meters
Gradient:
o Preferred gradient4%(1 in 25)
o Absolute maximum gradient 5% (1 in 20)
Type of parking, Stall size minimum, aisle width
o Parallel , 2.5 x 6.0m , 3.5meter
o 30degree, 2.5 x 5.0m, 3.5meter
o 45degree, 2.5 x 5.0m, 3.5meter
o 60degree, 2.5 x 5.0m, 3.5meter
o 90degree, 2.5 x 5.0m, 6.0meter
Structures permissible in the minimum prescribed Front setback, side setback and rear setback
Sun-shades0.60 meters Non continuous wardrobes or built-in cub boards above ground floor0.60 meters
Open non-continuous balconies (above ground floor)1.20 meters
Open service verandah to kitchen (above ground floor)1.20 meters
Architectural projections above ground floor1.00 meters
Staircase open landing projections (not affecting driveway)1.00meters
Cantilever portico so long as it does not fall within 1.5meters from the street alignment or
boundary of the site whichever is closer.
Special regulations for physically disabled shall be adhered to as follow:
Site planning:
o Every building should have at least one access to main entrance/exit to the disabled
which shall be indicated by proper signage. This entrance shall be approached
through a ramp together with stepped entry. The ramp should have a landing in
front of the doorway.
7/24/2019 HSS Assignment
4/12
Parking:
o Surface parking for at least two car spaces shall be provided near entrance for the
physically handicapped persons with maximum travel distance of 30 meters from
building entrance.
o
The width of parking bay shall be minimum 3.6 meters.o The information stating that the space is reserved for wheel chair users shall be
conspicuously displayed.
Building requirements:
o Ramps slope shall not be steeper than 1 in 12. Its length shall not exceed 9 meters
between landings and its width shall be minimum 1.5 meters with handrails on
either side;
o Among the lifts provided within the premises at least one lift shall have the facility
to accommodate the wheel chair size 80cm x 150cm.o The doors and doorways shall be provided with adequate width for free movement
of the disabled persons and it shall not be less than 90cm.
Rain water conservation:
Effective measures shall be taken within each premise for conservation of rainwater and
rainwater-harvesting structures at least to the following standards shall be provided; the
same shall be shown in the plan applied for planning permission.
Institutional buildings:o There shall be a pebble bed of 1 meter width and 1.5 meters depth all around the
building and filled with rounded pebbles of 5 centimeters to 7.5 centimeters size.
o The concrete paving around the building has to be sloped at about 1 in 20 towards
the pebble bed, so that rain water from the terrace and side open spaces flow over
this pavement and spread into the pebble bed around.
o Dwarf walls in masonry of 7.5 centimeters, height shall be constructed at the
entrance and exit gates to retard rainwater collected into the compound from
draining out to the road.
Additional regulations for all buildings:
o In the ground floor, floor level of water closets shall be at least 0.9 meter above the
road level to ensure free flow.
o A separate sump shall be constructed for storing potable water supplied by the
local body, the volume of sump not exceeding 1,000 liters per dwelling. This sump
7/24/2019 HSS Assignment
5/12
shall be independent of other tanks, which may be constructed for storing water
obtained from other sources.
Spaces excluded from Floor Space Index and coverage computation: The following shall not be
counted towards FSI and plot coverage computation:
Areas covered by stair-case rooms and lift rooms and passages thereto above the top most
storey, architectural features, chimneys, elevated tanks (provided its height below the tank
from the floor does not exceed 1.5 meters) and water closet (area not exceeding 10 square
meters).
Staircase and lift rooms and passage thereto in the stilt parking floor.
Lift wells in all the floors.
Area of fire escape staircase and cantilever fire escape passages.
7/24/2019 HSS Assignment
6/12
ASSESSMENT OF THE BUILDING AND COMPARING WITH THE REGIONAL BUILING
BYE-LAWS
SITE LOCATION: Institutional buildingOJASNIT Trichy
SITE AREA: 100m x 80m = 8000sq.m
BUILD UP AREA: G+2 = 7500sq.m (2500 sq.m each floor)
OPEN AREA: 1750sq.m
Floor Area Ratio(FAR) = 0.9
Height of the building12 meters
No. of entry/exit:
Main entry = 1 ; side entry = 4 (2 on each side)
No. of men and women toilets = 2 washrooms for each per floor
7/24/2019 HSS Assignment
7/12
PHOTOS OF THE BUILDING FOR ASSESSMENT, SHOWING THE IMPACTS
No parking space is provided at the front of the
building which leads to random parking by the
users in the front.
Parking space is provided at the side of the
building which is not visible and so it is not
much used.
(Rule not followed - Surface parking for at least
two car spaces shall be provided near entrance
for the physically handicapped persons)
All ACs outdoor units are placed on the frontelevation wall of the building which creates an
unpleasant scene. No proper arrangement for
the drain pipes.
Front set back is not measurable since there is
no boundary wall for the building.
(Rule not followed - The concrete paving
around the building has to be sloped at about 1
in 20 towards the pebble bed, so that rain
water from the terrace and side open spaces
flow over this pavement)
Drainage pipes are not properly covered
with ducts which may lead to leakage and
damage elevation wall of the building.
The drain pipe of the ACs outdoor unit is
not connected well to the ground.
The width of the lift door is only 1meter which is small for
the wheel chair to go in comfortably.
(Rule not followed - Among the lifts provided within the
premises at least one lift shall have the facility to
accommodate the wheel chair size 80cm x 150cm).
7/24/2019 HSS Assignment
8/12
The staircase is direct and easily accessible by
the users.
Rule followed - The width of the staircase is
2meter, which is minimum width for the
institutional building.
The distance between the two internal
staircases is about 15 meters, which is more for
the user to walk that far.
The ratio of the built-up area to the open area
in the building is more, which is comfortable
and spacious.
The width to height ratio is more which causesmore direct sunlight into the opposite corridors
and the open space, since not much shade of
the building falls on it.
A total of 4 staircase and 2 lifts are provided
but no fire extinguishing system is installed.
There is no rain water conservation system and the
drain pipe from which water is coming from the terrace
directly flows on the floor, making the floor slippery
during rain.
(Rule not followed all the drain pipes are not
connected to the rain water conservation system)
Sufficient number of toilets for men and
women are provided in each floor.
But they are located on far end of the
building which is difficult for the user to
find out and walk so far.
7/24/2019 HSS Assignment
9/12
The distance from one side entry to the other
side entry is almost 80meters which is very
far for a person to walk towards the other
end in the building.
Other staircase is provided almost in the
middle of the building but the distance
between the two staircases is almost 15-20m
which is far for the users to walk.
This staircase comes in the open area of the
building and it is projecting out which is
clearly visible by the users.
Some open space between the staircase and
the paved area in the courtyard is provided
for landscape but it is not properly used.
The area that is supposed to be for growing
plants and landscaping is used as a dumping
zone where all the unused building materials
are dumped.
Provisions are made for the rain water and
surface water from the floors to get collected
into the drain which is running all around the
courtyard, through the drain pipe.
7/24/2019 HSS Assignment
10/12
Provisions were made for lifts in the early
stages of the building construction but later it
is not being used.
No provisions for lift were made after the
completion of the building and now the place
is used as a storage space for the unused
furniture.
The space is not closed with door which
causes unpleasant scene in the building.
The lift space which is now unused wascovered with marble flooring but the lift well
was not closed and no such provisions were
given so that people come closer to it.
The entire lift well was left open as such from
top to bottom which is dangerous for the
users, since people may fall into it
accidentally.
Electrical equipment was kept open in the
corner of the floor with all wiring being open.
This space was actually meant for the water
cooler but it is being misused and it has a sink
at the side of it, it was meant for refreshment
for the users.
There is only water cooler for the entire
building at the ground floor which is not
sufficient for the users of the building.
7/24/2019 HSS Assignment
11/12
A balcony space is provided in first and second floornear the labs for refreshment but that is used as a
storage space and all the unused furniture is
dum ed there.
Gas cylinders that are used in the lab areplaced outside on the floor and no fire
extinguisher is there in the building which is
ver dan erous for the users.
All the drain pipes from the toilets are left open without covering them with ducts which
causes an unpleasant scene, since it is on the side entry of the building which is often
used by the people after they park their vehicles in the parking zones at the side.
7/24/2019 HSS Assignment
12/12
Parking space for the cycles and the bikes is provided at the side of the building, which is not visible
for the users approaching the building from the front. This leads to more parking in the front of the
building than at the sides where parking space is provided.
Car parking space is insufficient for this building and so many users park their car on the road
abutting the side of the building or in front of the building causing disturbance for other people
The sewer pipe connecting to the tank at
the ground is not properly maintained and
not closed.
This causes an unpleasant scene and may
lead to health problems for the users and to
the surroundings.