HSS Assignment

download HSS Assignment

of 12

Transcript of HSS Assignment

  • 7/24/2019 HSS Assignment

    1/12

    HUMAN SETTLEMENT SCIENCEII

    ASSIGNMENT -1

    BUILDING TAKENINSTITUTIONAL BUILDINGOJASNITT

    SHUBANI CHANDRA J

    101111017

  • 7/24/2019 HSS Assignment

    2/12

    BYELAWS to be followed for the institutional buildingOJASis referred from the Local Planning

    Area regulations of the Tiruchirappalli corporation

    Variation to the Master Plan for Tiruchirappalli Local Planning Area

    [G.O.Ms. No. 130, Housing and Urban Development (UD4-1), 14th June 2010.]

    No. II(2)/HOU/379/2010.In exercise of powers conferred by sub-section (4) of section 32 of the

    Tamil Nadu Town and Country Planning Act, 1971 (Tamil Nadu Act 35 of 1972), the Governor of

    Tamil Nadu hereby makes the following variation to the master plan for Tiruchirappalli Local

    Planning Area approved under the said Act and published with the Housing and Urban

    Development Department Notification No.II(2)/HOU/453/2009 at page 319 of Part IISection 2 of

    the Tamil Nadu Government Gazette, dated the 2nd September 2009.

    PLANNING PARAMETERS:

    Minimum road width9m

    Maximum height of the building15m or G+3 or Stilt + 4 floors

    Maximum floor space index (FSI)1.5

    Maximum plot coverage60%

    Front set back

    o Min 3m; Up to 18m3m; 18m to 24m4.5m. More than 24m & NH & SH7m.

    Side set back - 3m. or 1/4th height whichever is higher

    Rear set back - 3m. or 1/4th height whichever is higher

    Open space reservationas per Schedule 1

    Parking spaceas per Schedule 2

    Minimum width of corridorInstitutional buildingschools and colleges2.0meters

    Special regulations for physically disabledSchedule 4

    Rain water conservationSchedule 5

    Vehicular ramp in setback spaces around building blocks may be permitted subject to the

    condition that the clearance of the proposed ramp from the property boundary/street

    alignment shall be minimum 1.5 meters and a clear motor able driveway of minimum 3.5

    meters in width is available around the building block.

    Parking standards: Educational buildings:

    Floor area less than 100 sq.mnil

    Floor area above 100sq.m but less than 1000sq.m one car space for every 200sq.m of

    floor area.

  • 7/24/2019 HSS Assignment

    3/12

    For every additional 100 sq.m of floor area or part thereof over 1000sq.mone car space.

    Dimensions:

    o The dimension of parking stall shall be 5.0m x 2.5m with a minimum which width of

    driveway of 3.5m for one way movement and 7.2m width for two way movement.

    In the case of ware house and go downs and industries the dimension of parkingstall shall be 10m x 3.75m with a minimum width of driveway of 3.75m. The

    number of car spaces required will be calculated on 75% of the total floor area of

    the building.

    Radius: Minimum inside radius of lane 4.5meters

    Gradient:

    o Preferred gradient4%(1 in 25)

    o Absolute maximum gradient 5% (1 in 20)

    Type of parking, Stall size minimum, aisle width

    o Parallel , 2.5 x 6.0m , 3.5meter

    o 30degree, 2.5 x 5.0m, 3.5meter

    o 45degree, 2.5 x 5.0m, 3.5meter

    o 60degree, 2.5 x 5.0m, 3.5meter

    o 90degree, 2.5 x 5.0m, 6.0meter

    Structures permissible in the minimum prescribed Front setback, side setback and rear setback

    Sun-shades0.60 meters Non continuous wardrobes or built-in cub boards above ground floor0.60 meters

    Open non-continuous balconies (above ground floor)1.20 meters

    Open service verandah to kitchen (above ground floor)1.20 meters

    Architectural projections above ground floor1.00 meters

    Staircase open landing projections (not affecting driveway)1.00meters

    Cantilever portico so long as it does not fall within 1.5meters from the street alignment or

    boundary of the site whichever is closer.

    Special regulations for physically disabled shall be adhered to as follow:

    Site planning:

    o Every building should have at least one access to main entrance/exit to the disabled

    which shall be indicated by proper signage. This entrance shall be approached

    through a ramp together with stepped entry. The ramp should have a landing in

    front of the doorway.

  • 7/24/2019 HSS Assignment

    4/12

    Parking:

    o Surface parking for at least two car spaces shall be provided near entrance for the

    physically handicapped persons with maximum travel distance of 30 meters from

    building entrance.

    o

    The width of parking bay shall be minimum 3.6 meters.o The information stating that the space is reserved for wheel chair users shall be

    conspicuously displayed.

    Building requirements:

    o Ramps slope shall not be steeper than 1 in 12. Its length shall not exceed 9 meters

    between landings and its width shall be minimum 1.5 meters with handrails on

    either side;

    o Among the lifts provided within the premises at least one lift shall have the facility

    to accommodate the wheel chair size 80cm x 150cm.o The doors and doorways shall be provided with adequate width for free movement

    of the disabled persons and it shall not be less than 90cm.

    Rain water conservation:

    Effective measures shall be taken within each premise for conservation of rainwater and

    rainwater-harvesting structures at least to the following standards shall be provided; the

    same shall be shown in the plan applied for planning permission.

    Institutional buildings:o There shall be a pebble bed of 1 meter width and 1.5 meters depth all around the

    building and filled with rounded pebbles of 5 centimeters to 7.5 centimeters size.

    o The concrete paving around the building has to be sloped at about 1 in 20 towards

    the pebble bed, so that rain water from the terrace and side open spaces flow over

    this pavement and spread into the pebble bed around.

    o Dwarf walls in masonry of 7.5 centimeters, height shall be constructed at the

    entrance and exit gates to retard rainwater collected into the compound from

    draining out to the road.

    Additional regulations for all buildings:

    o In the ground floor, floor level of water closets shall be at least 0.9 meter above the

    road level to ensure free flow.

    o A separate sump shall be constructed for storing potable water supplied by the

    local body, the volume of sump not exceeding 1,000 liters per dwelling. This sump

  • 7/24/2019 HSS Assignment

    5/12

    shall be independent of other tanks, which may be constructed for storing water

    obtained from other sources.

    Spaces excluded from Floor Space Index and coverage computation: The following shall not be

    counted towards FSI and plot coverage computation:

    Areas covered by stair-case rooms and lift rooms and passages thereto above the top most

    storey, architectural features, chimneys, elevated tanks (provided its height below the tank

    from the floor does not exceed 1.5 meters) and water closet (area not exceeding 10 square

    meters).

    Staircase and lift rooms and passage thereto in the stilt parking floor.

    Lift wells in all the floors.

    Area of fire escape staircase and cantilever fire escape passages.

  • 7/24/2019 HSS Assignment

    6/12

    ASSESSMENT OF THE BUILDING AND COMPARING WITH THE REGIONAL BUILING

    BYE-LAWS

    SITE LOCATION: Institutional buildingOJASNIT Trichy

    SITE AREA: 100m x 80m = 8000sq.m

    BUILD UP AREA: G+2 = 7500sq.m (2500 sq.m each floor)

    OPEN AREA: 1750sq.m

    Floor Area Ratio(FAR) = 0.9

    Height of the building12 meters

    No. of entry/exit:

    Main entry = 1 ; side entry = 4 (2 on each side)

    No. of men and women toilets = 2 washrooms for each per floor

  • 7/24/2019 HSS Assignment

    7/12

    PHOTOS OF THE BUILDING FOR ASSESSMENT, SHOWING THE IMPACTS

    No parking space is provided at the front of the

    building which leads to random parking by the

    users in the front.

    Parking space is provided at the side of the

    building which is not visible and so it is not

    much used.

    (Rule not followed - Surface parking for at least

    two car spaces shall be provided near entrance

    for the physically handicapped persons)

    All ACs outdoor units are placed on the frontelevation wall of the building which creates an

    unpleasant scene. No proper arrangement for

    the drain pipes.

    Front set back is not measurable since there is

    no boundary wall for the building.

    (Rule not followed - The concrete paving

    around the building has to be sloped at about 1

    in 20 towards the pebble bed, so that rain

    water from the terrace and side open spaces

    flow over this pavement)

    Drainage pipes are not properly covered

    with ducts which may lead to leakage and

    damage elevation wall of the building.

    The drain pipe of the ACs outdoor unit is

    not connected well to the ground.

    The width of the lift door is only 1meter which is small for

    the wheel chair to go in comfortably.

    (Rule not followed - Among the lifts provided within the

    premises at least one lift shall have the facility to

    accommodate the wheel chair size 80cm x 150cm).

  • 7/24/2019 HSS Assignment

    8/12

    The staircase is direct and easily accessible by

    the users.

    Rule followed - The width of the staircase is

    2meter, which is minimum width for the

    institutional building.

    The distance between the two internal

    staircases is about 15 meters, which is more for

    the user to walk that far.

    The ratio of the built-up area to the open area

    in the building is more, which is comfortable

    and spacious.

    The width to height ratio is more which causesmore direct sunlight into the opposite corridors

    and the open space, since not much shade of

    the building falls on it.

    A total of 4 staircase and 2 lifts are provided

    but no fire extinguishing system is installed.

    There is no rain water conservation system and the

    drain pipe from which water is coming from the terrace

    directly flows on the floor, making the floor slippery

    during rain.

    (Rule not followed all the drain pipes are not

    connected to the rain water conservation system)

    Sufficient number of toilets for men and

    women are provided in each floor.

    But they are located on far end of the

    building which is difficult for the user to

    find out and walk so far.

  • 7/24/2019 HSS Assignment

    9/12

    The distance from one side entry to the other

    side entry is almost 80meters which is very

    far for a person to walk towards the other

    end in the building.

    Other staircase is provided almost in the

    middle of the building but the distance

    between the two staircases is almost 15-20m

    which is far for the users to walk.

    This staircase comes in the open area of the

    building and it is projecting out which is

    clearly visible by the users.

    Some open space between the staircase and

    the paved area in the courtyard is provided

    for landscape but it is not properly used.

    The area that is supposed to be for growing

    plants and landscaping is used as a dumping

    zone where all the unused building materials

    are dumped.

    Provisions are made for the rain water and

    surface water from the floors to get collected

    into the drain which is running all around the

    courtyard, through the drain pipe.

  • 7/24/2019 HSS Assignment

    10/12

    Provisions were made for lifts in the early

    stages of the building construction but later it

    is not being used.

    No provisions for lift were made after the

    completion of the building and now the place

    is used as a storage space for the unused

    furniture.

    The space is not closed with door which

    causes unpleasant scene in the building.

    The lift space which is now unused wascovered with marble flooring but the lift well

    was not closed and no such provisions were

    given so that people come closer to it.

    The entire lift well was left open as such from

    top to bottom which is dangerous for the

    users, since people may fall into it

    accidentally.

    Electrical equipment was kept open in the

    corner of the floor with all wiring being open.

    This space was actually meant for the water

    cooler but it is being misused and it has a sink

    at the side of it, it was meant for refreshment

    for the users.

    There is only water cooler for the entire

    building at the ground floor which is not

    sufficient for the users of the building.

  • 7/24/2019 HSS Assignment

    11/12

    A balcony space is provided in first and second floornear the labs for refreshment but that is used as a

    storage space and all the unused furniture is

    dum ed there.

    Gas cylinders that are used in the lab areplaced outside on the floor and no fire

    extinguisher is there in the building which is

    ver dan erous for the users.

    All the drain pipes from the toilets are left open without covering them with ducts which

    causes an unpleasant scene, since it is on the side entry of the building which is often

    used by the people after they park their vehicles in the parking zones at the side.

  • 7/24/2019 HSS Assignment

    12/12

    Parking space for the cycles and the bikes is provided at the side of the building, which is not visible

    for the users approaching the building from the front. This leads to more parking in the front of the

    building than at the sides where parking space is provided.

    Car parking space is insufficient for this building and so many users park their car on the road

    abutting the side of the building or in front of the building causing disturbance for other people

    The sewer pipe connecting to the tank at

    the ground is not properly maintained and

    not closed.

    This causes an unpleasant scene and may

    lead to health problems for the users and to

    the surroundings.