HHJ6/8/10-LED INSTRUCTIONS
SAFETY INSTRUCTIONS 1. Do not use outdoors. 2. Equipment should be mounted securely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. 3. Do not mount near gas or electric heaters. 4. Cap unused wires with enclosed wire nuts or other approved method. 5. Do not use this equipment for anything other than its intended use. 6. The use of accessory equipment not recommended by the manufacturer will void product listing and warranty and may cause an unsafe condition. 7. Use caution when servicing batteries. 8. Any service on this equipment should be performed by qualified personnel only. 9. Make sure wire terminations are secure and leads are properly tucked in appropriate wire channels. CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING
PAGE 1 OF 4
Catalog# HHJ6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000L/5000LO.R.-Revision B: 5/4/20
323-888-1973 techsupport@iuseelite.com www.iuseelite.com
Caution: Disconnect AC power before servicing and installation.All electrical connections must be in accordance withNEC/CEC or your local code.
Lay down the EMG driver in the drywall ceiling..
Instructions Steps
Emergency Test Switch
Gut out existing reflectorand wiring from mounting
frame and j-box respectively
If needed remove any existing friction blades clipsfrom the mounting frame.
Architectural High Lumen LED Downlight- Retrofit
1 2 3
Integral Test Switch Remote Mount Test Switch
Emergency Driver Mounting
EMG LED Driver
Test Switch J-Box(J-Box not provided)
Old Luminaire'sJ-Box
Power
Screw in MFG-BK-HHJ6-8-10-L bracket into
existing mounting frame.
HHJ6/8/10-LED INSTRUCTIONSPAGE 2 OF 4
Catalog# HHJ6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000L/5000LO.R.-Revision B: 5/4/20
323-888-1973 techsupport@iuseelite.com www.iuseelite.com
Instructions Steps (Continuation)
Apply plaster or spackle over mesh ring. Once dry sand surface for
a finished look.
7
Insert
Cover
Architectural High Lumen LED Downlight- Retrofit
4
Insert the flange trim by squeezing v-spring into the bracket slot
Flange Trim Installation
7
END OF FLANGE TRIM
Push up the reflector then rotate it counter clockwise to secure the twist screws into reflector slots. Tighten
both twist screws.
5 6
Flangeless Trim Installation
65
Insert the mesh ring. Friction blades will hold it in place. Screw in the screws.
Insert Cover
Feed the regular LED driver through hole opening and lay it down in
the drywall
Connect all electrical connectionsin the old junction box. For wiring diagram please refer to last page.
HHJ6/8/10-LED INSTRUCTIONSPAGE 3 OF 4
Catalog# HHJ6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000L/5000LO.R.-Revision B: 5/4/20
323-888-1973 techsupport@iuseelite.com www.iuseelite.com
Flangeless Trim Installation (Continuation)
10
END OF FLANGELESS TRIM
Architectural High Lumen LED Downlight- Retrofit
Insert the flange trim by squeezing v-spring into the bracket slot
98
Push up the reflector then rotate it counter clockwise to secure the twist screws into reflector slots. Tighten
both twist screws.
HHJ6/8/10-LED WIRING DIAGRAMPAGE 4 OF 4
Catalog# HHJ6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000L/5000LO.R.-Revision B: 5/4/20
323-888-1973 techsupport@iuseelite.com www.iuseelite.com
DIM10 DIMMING WIRING (0-10V Dimming)
DIMTR/LUT2W DIMMING WIRING (Line Voltage Dimming)
DALI DIMMING WIRING
DMX DIMMING WIRING
Fixture
W
B
G
Gr
P
W
B
G
Gr
P
Color Func�on
W White Neutral
B Black Hot
G Green Ground
Gr Gray Dim10-
P Purple Dim10+
Recommended Dimming Class 2 Cable
18-2C-LVBP
Class 2 Cable
Class 1 ConduitJunction
Box Fixture
Class 1 Conduit
Junction Box Fixture
FixtureW
B
G
W
B
G
Color Func�on
W White Neutral
B Black Hot
G Green Ground
Fixture
W
B
G
P
P
W
B
G
P
P
Class 2 Cable
Class 1 ConduitJunction
Box Fixture
*E1 and E2 (EcoSystem digital link wires) are polarity‑insensitive and can be wired in any topology.
LUTH DIMMING WIRING (Lutron Ecosystem)
Color Func�on
W White Neutral
B Black Hot
G Green Ground
P Purple E1*
P Purple E2*
Class 2 Cable
Class 1 ConduitJunction
Box Fixture
Recommended Dimming Class 2 Cable
18-2C-LVBP
Fixture
W
B
G
W
B
G
DMX+
DMX-
Common
DMX+
DMX-
Common
Color Func�on
W White Neutral
B Black Hot
G Green Ground
O Orange DMX+
Bl Blue DMX-
B/W Blue/White DMX Common
DMX Driver
STEP DIMMING WIRING
Fixture
W
B
G
W
B
BB
G
Class 1 Conduit
Junction Box Fixture
Color Func�on
W White Neutral
B Black Switch 1
B Black Switch 2
G Green Ground
Fixture
W
B
G
Control 1
Control 2
DALICONTROLLER
W
B
G
Control 1
Control 2
Class 2 Cable
Class 1 ConduitJunction
Box Fixture
DALICONTROLLER
Color Func�on
W White Neutral
B Black Hot
G Green Ground
O Orange DA+
Bl Blue DA-
Architectural High Lumen LED Downlight- Retrofit