Post on 28-Jul-2020
Goodrive100-01 Series Inverter Special for PV Water Pumps
D
Multi -function input terminal 1
Multi -function input terminal 2
Multi -function input terminal 3
Multi -function input terminal 4
High speed pulse input
Open co llector input
frequency setting power supply
multi -function analog input
analog output
analog output
Relay output 1
Relay output 2
Wall installation
Output voltage
Linear type
Square type
Output frequency
1.3th power off V/Fcurve1.7th power off V/Fcurve2.0th power off V/Fcurve
Output voltage
Output frequency
boos t
cut- off
S1
S4
S3
S2PB
(+)
M
U V W
R S T
HDICOM
GND
10V
AI2
AI3RO2A
RO1BRO1A
RO2BRO2C
RO1C
24VPWPE
AO1
AO2
485-485+
(-)
Q2
PVmodules
Run/Stop
Reservoir
B1
B2
S1
S4
S3
S2
PB
(+)
M
U V W
R S T
Q1
HDI
COM
GND
10V
AI2
AI3RO2A
RO1BRO1A
RO2B
RO2C
RO1C
24VPWPE
AO1
AO2
485-
485+
(-)
Q2
The grid
PV voltagereferenceenabling
B1
B2
Protectiondiode
Note: If there is no diode protectionat the bus input, Q2 and Q1 can notbe switched on at the same time,otherwise, damage may occur to thebuttery board.
PVmodules
Run/Stop
Reservoir
201405(V1.2)
Industrial Automation:
Electric Power: SVG