ELECTRICAL MACHINES LAB-1List of experiments
1. Magnetization characteristics of DC shunt generator.Determination of critical field response.
2. Brake test on DC shunt motor. Determination of performancecurves.
3. Load test on DC series generator. Determination of characteristics.
4. Load test on DC compound generator. Determination of characteristics.
5. Swinburns test and speed control of DC shunt motor. Pre-determination of efficiency.
6. Load test on DC shunt generator. Determination of characteristics.
7. Hopkinsons test on DC shunt machines.
8. Brake test on DC compound motor. Determination of performancecurves
9. Retardation test on DC shunt motor. Determination of losses atrated speed.
10. Separation of losses in DC shunt motor .
7/30/2019 EM-I manual
2/35
ELECTRICAL MACHINES LAB-1
EXP-1. MAGNETIZATION CHARACTERISTICS OFDC SHUNT GENERATOR
AIM : To draw the magnetization characteristics or open circuit characteristics of a self excited DC shunt generator and to determine Critical resistance, critical speed.
NAME PLATE DETAILS:
1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:
S.NO Name of theequipment
Range Type Quantity
CIRCUIT DIAGRAM :
7/30/2019 EM-I manual
3/35
THEORY:
PRECAUTIONS:
1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE:
1. make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit.3. Switch on the supply and run the generator with out load.4. Vary the field current in the steps using the field rheostat.
i) Increasing mode: increase the field current in steps and not down thevalues of Field current (I f ) and Generated e.m.f (E) at each step.
ii) Decreasing mode: Decrease se the field current in steps and not downthe values of Field current (I f ) and Generated e.m.f (E) at each step.
5. Plot the graph between the average value (increasing and decreasing) of Fieldcurrent (I f ) and Generated e.m.f (E)
6. Find the critical resistance and critical speed
OBSERVATIONS :
S.No Field current (I f )(amps)
Generated e.m.f (E)(Vots)
Increasing mode Decreasing mode Increasing mode Decreasing mode
7/30/2019 EM-I manual
4/35
SAMPLE CALCULATIONS:
EXPECTED GRAPH:
Field current (I f ) Vs Generated e.m.f (E G)
RESULTS AND CONCLUSION:
7/30/2019 EM-I manual
5/35
ELECTRICAL MACHINES LAB-1
EXP. 2. BRAKE TEST ON DC SHUNT MOTOR.
AIM : To study the performance of DC shunt motor by conducting Brake test.
NAME PLATE DETAILS :1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:
S.NO Name of theequipment Range Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
6/35
THEORY:
PRECAUTIONS:
1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.5. Release the load on the motor before switch OFF the supply
PROCEDURE:
1. Make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit.3. Switch on the supply and slowly push the starter till the end and run the motor
with out load.4. Adjust the speed of the motor to the rated value by adjusting field resistance .5. Take the Noload readings of ammeter, voltmeter and speed.6. Slowly increase the load on the brake pulley by tightening the wheels in steps. At
each step note down the ratings ammeter, voltmeter, spring balance readings andspeed.
7. Release the load on the pulley and switch OFF the supply
OBSERVATIONS :S.No S1
(kgs)S2(kgs)
Load(S1-S2)(kgs)
Speed(N)(rpm)
Voltage(V)(volts)
Current(I)(amps)
Torque(T)(N-M)
O/PPower (watts)
I/P power (watts)
Efficiency( )
Torque T = (S 1 S 2)*R*9.81 N-MMotor output = 2NT/60 watts.Motor input = VI watts.Efficiency = output/ input =2NT/60*VI
7/30/2019 EM-I manual
7/35
SAMPLE CALCULATIONS:
GRAPHS:
1. Efficiency Vs output.2. Speed Vs output3. Torque Vs output
4. Load current Vs output5. speed Vs output
RESULTS AND CONCLUSION:
7/30/2019 EM-I manual
8/35
ELECTRICAL MACHINES LAB-1
EXP-3. LOAD TEST ON DC SERIES GENERATOR.
AIM : To perform the load test on DC series generator and to draw the internal andexternal characteristics.
NAME PLATE DETAILS:1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:
S.NO Name of theequipment Range Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
9/35
THEORY:
PRECAUTIONS:
1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the machine ON load.
PROCEDURE:
1. Make the connection as per the circuit diagram.2. The motor generator set is started and brought to rated speed my varying themotor field rheostat.
3. When it is running at rated speed the generated field is adjusted to get ratedvoltage on no load.
4. The generator field rheostat is not disturbed through out the experiment.5. Load is put in steps on the generator the speed is adjusted to rated value for each
load and the load current I L and terminal voltage V are noted.6. The step 5 is repeated till the generator is over loaded by about 25%.
OBSERVATIONS :
S.No Load current (I L)(amps)
Terminal voltage (V T)(volts)
EMF Generated (E g)(volts)
EMF Generated (E g)=V + I aR a (volts).
SAMPLE CALCULATIONS:
7/30/2019 EM-I manual
10/35
GRAPHS:
1. Internal characteristics: E g Vs I L2. External characteristics: V T Vs I L
RESULTS AND CONCLUSION:
7/30/2019 EM-I manual
11/35
ELECTRICAL MACHINES LAB-1
EXP-4. LOAD TEST ON DC COMPOUND GENERATOR.
AIM : : To perform the load test on DC compound generator and draw the internal andexternal characteristics.
NAME PLATE DETAILS:1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:
S.NO Name of theequipment Range Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
12/35
THEORY:
PRECAUTIONS:
1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE:1. Make the connection as per the circuit diagram.2. The motor generator set is started and brought to rated speed my varying the
motor field rheostat.3. When it is running at rated speed the generated field is adjusted to get rated
voltage on no load.4. The generator field rheostat is not disturbed through out the experiment.5. Load is put in steps on the generator the speed is adjusted to rated value for each
load and the load current I L, shunt Field current I sh and terminal voltage V arenoted.
6. The step 5 is repeated till the generator is over loaded by about 25%.
OBSERVATIONS :
S.No Terminalvoltage (V T)(volts)
Load current (I L)(amps)
Shunt fieldcurrent (I sh)(amps)
Ia= I sh+ I L(amps)
E=V T+ I aR a(volts)
SAMPLE CALCULATIONS:
7/30/2019 EM-I manual
13/35
GRAPHS:
1. Internal characteristics: E g Vs I L2. External characteristics: V T Vs I L
RESULTS AND CONCLUSION
7/30/2019 EM-I manual
14/35
ELECTRICAL MACHINES LAB-1
EXP-5(A). SWINBURNS TEST ON DC SHUNT MOTOR
AIM : To perform the Swinburns test on given DC shunt machine and predetermine itsefficiency at any desired load both as motor and as generator.
NAME PLATE DETAILS:
1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:
S.NO Name of theequipment
Range Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
15/35
THEORY:
PRECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE:
1. make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit.3. Switch on the supply and run the motor at rated speed by adjusting the field
rheostat.4. take the readings of Line current I L0, shunt Field current I sh and terminal voltage
VT
OBSERVATIONS :1. No load Line current I L0:2. shunt Field current I sh :3. Terminal voltage V T:
Running as a motorArmature current R a=Rated current I r =Armature current for motor I ao= I 0-I f Constant losses (Wco) =Field current (I f ) =Terminal voltage V=
S.No Fractionof load
Loadcurrent
IL=X* I r
Armaturecurrent
Ia= I L*I f
Armaturecu losses
Wcu=Ia2R a
Totallosses
WT= Wco+Wcu
Input power
Wi=VI L
Output power
Wo= Wi-Wt
Efficiency = Wo/
Wi
Amps Amps Watts Watts Watts Watts %1. 1/42. 1/23. 3/44. 1
7/30/2019 EM-I manual
16/35
Running as a generator:Armature current R a=Rated current I r =Armature current for motor I ao= I 0+I f Constant losses (Wco) =
Field current (I f ) =Terminal voltage V=
S.No Fractionof load
LoadcurrentIL=X* I r
ArmaturecurrentIa= I L*i f
Armaturecu lossesWcu=Ia2R a
TotallossesWT= Wco+Wcu
Input power Wi=VI L
Output power Wo= Wi-Wt
Efficiency = Wo/Wi
Amps Amps Watts Watts Watts Watts %1. 1/42. 1/23. 3/44. 1
SAMPLE CALCULATIONS:
RESULTS AND CONCLUSION :
7/30/2019 EM-I manual
17/35
ELECTRICAL MACHINES LAB-1
EXP-5(B). SPEED CONTROL OF A DC SHUNT MOTOR AIM : To control the speed of the DC shunt motor by varying field current an armaturevoltage.
NAME PLATE DETAILS:
5. voltage :6. current :7. H.P/KW rating:8. speed :
APPARATUS REQUIRED:
S.NO Name of the
equipment
Range Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
18/35
THEORY:
PRECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.5.
PROCEDURE:
1. make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit andmaximum resistance in armature circuit.
3. Switch on the supply and run the motor at rated speed by adjusting the fieldrheostat.
4. Vary the field regulator in steps and take the readings of shunt Field current I f andspeed for each step.
5. keep the field rheostat in minimum position again.6. Vary the armature regulator in steps and take the readings of armature voltage V
and speed for each step.7. plot the graphs
OBSERVATIONS :
Field current control method :S.No Field current I f
(amps)Speed N(rpm)
Armature voltage method:S.No armature voltage V
(volts)Speed N(rpm)
7/30/2019 EM-I manual
19/35
SAMPLE CALCULATIONS:
GRAPH:
1. Armature voltage V Vs speed
2. Field current I f Vs speed
RESULTS AND CONCLUSION:
7/30/2019 EM-I manual
20/35
ELECTRICAL MACHINES LAB-1
EXP-6. LOAD TEST ON DC SHUNT GENERATOR
AIM : To perform the load test on DC compound generator and draw the internal andexternal characteristics
NAME PLATE DETAILS:1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:S.NO Name of the
equipmentRange Type Quantity
CIRCUIT DIAGRAM:
THEORY:
7/30/2019 EM-I manual
21/35
PRECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE:1. Make the connection as per the circuit diagram.2. The motor generator set is started and brought to rated speed my varying the
motor field rheostat.3. When it is running at rated speed the generated field is adjusted to get ratedvoltage on no load.
4. The generator field rheostat is not disturbed through out the experiment.5. Load is put in steps on the generator the speed is adjusted to rated value for each
load and the load current I L, shunt Field current I sh and terminal voltage V arenoted.
6. The step 5 is repeated till the generator is over loaded by about 25%.
OBSERVATIONS :
S.No Terminalvoltage (V T)(volts)
Load current (I L)(amps)
Shunt fieldcurrent (I sh)(amps)
Ia= I sh+ I L(amps)
E=V T+ I aR a(volts)
SAMPLE CALCULATIONS:
7/30/2019 EM-I manual
22/35
GRAPHS:1. Internal characteristics: E g Vs I L
2. External characteristics: V T Vs I L
RESULTS AND CONCLUSION:
7/30/2019 EM-I manual
23/35
ELECTRICAL MACHINES LAB-1
EXP-7: HOPKINSONS TEST OR REGENERATIVESTEST (BACK TO BACK TEST)
AIM : To perform Hopkinsons test on DC shunt machines.
NAME PLATE DETAILS:1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:S.NO Name of the
equipmentRange Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
24/35
THEORY:
PRECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE :1. make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit.3. Switch on the supply and start the motor whereas the switch S of the other
machine is open.4. Adjust the speed of the motor to its rated value by the rheostat.5. Adjust the voltage of the generator by the field rheostst until the voltmeter V 1
reads zero, there by showing that its voltage is same, both in polarity andmagnitude as that of the main supply.
6. Close the switch S to run the machine in parallel.7. Note down the reading of I 1, I2, I3, I4, I5 and V8. Repeat the procedure for different generator armature currents.
OBSERVATIONS:SNo Voltage
(volts)I1(amps)
I2(amps)
I3(amps)
I4
(amps)I5(amps)
Motor input(watts)
Motor output(watts)
Motor efficiency%
generator input(watts)
generator output(watts)
Generator efficiency%
CALCULATIONS: I1=I2=I3=I4=
I5 =V=
Total losses:
7/30/2019 EM-I manual
25/35
Armature copper losses in motor= I 22R a wattsShunt copper losses in motor=V I 3 wattsArmature copper losses in generator = I 42R a wattsShunt copper losses in generator = V I 5 wattsMotor drawn supply from the supply= V I 1 watts
Total stray losses= V I1-[I 22
Ra +I 42
R a] watts.Stray losses for each machine =W/2 watts.
Motor input:=Armature input + Shunt field input=V I 2 +V I 3.Motor losses: Armature copper losses +Shunt copper losses +Stray losses=I22R a+V I 3 +W/2 (watts).
Motor output:Motor input losses.
Motor efficiency: output/ input.Generator output: V (I 4-I5 ) watts
Generator losses: Armature copper losses +Shunt copper losses +Stray losses=I42R a + V I 5 +W/2 ( watts).
Generator input= output= losses.
Generator efficiency: output/ input.
RESULTS AND CONCLUSION
ELECTRICAL MACHINES LAB-1
7/30/2019 EM-I manual
26/35
EXP-8. BRAKE TEST ON DC COMPOUND MOTOR.
AIM : To study the performance of DC compound motor by conducting Brake test.
NAME PLATE DETAILS:1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:S.NO Name of the
equipmentRange Type Quantity
CIRCUIT DIAGRAM:
THEORY:
7/30/2019 EM-I manual
27/35
PRECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.5. Release the load on the motor before switch OFF the supply
PROCEDURE:1. make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit.
3. Switch on the supply and slowly push the starter till the end and run the motor with out load.4. Adjust the speed of the motor to the rated value by adjusting field resistance .5. Take the Noload readings of ammeter, voltmeter and speed.6. Slowly increase the load on the brake pulley by tightening the wheels in steps. At
each step note down the ratings ammeter, voltmeter, spring balance readings andspeed.
7. Release the load on the pulley and switch OFF the supply
OBSERVATIONS :S.No S1
(kgs)S2(kgs)
Load(S1-S2)(kgs)
Speed(N)(rpm)
Voltage(V)(volts)
Current(I)(amps)
Torque(T)(N-M)
O/PPower (watts)
I/P power (watts)
Efficiency( )
Torque T = (S 1 S 2)*R*9.81 N-MMotor output = 2NT/60 watts.Motor input = VI watts.Efficiency = output/ input =2NT/60*VI
SAMPLE CALCULATIONS:
7/30/2019 EM-I manual
28/35
GRAPHS:
1. Efficiency Vs output.2. Speed Vs output3. Torque Vs output4. Load current Vs output5. speed Vs output
RESULTS AND CONCLUSION:
ELECTRICAL MACHINES LAB-1
EXP -9. RETARDATION TEST
7/30/2019 EM-I manual
29/35
AIM : To conduct a Retardation test on DC shunt motor and to determine dn/dt anddetermination of losses at rated speed.
NAME PLATE DETAILS:
1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:S.NO Name of the
equipmentRange Type Quantity
CIRCUIT DIAGRAM:
THEORY:
PRECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.
7/30/2019 EM-I manual
30/35
3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE:5. make the connection as per the circuit diagram
6. Ensure minimum resistance (rheostat in min position) in the field circuit.7. Switch on the supply and run the motor at rated speed by adjusting field rheostat.8. Raise speed to 1700 rpm (above rated speed) by adjusting field rheostat.9. open the DPST switch and start stop watch at 1650 rpm find T 1 while coasting
down to 1500 rpm.10. repeat procedure 2 for different speeds starting from 1650.
OBSERVATIONS :
Sno N 1rpm
N2Rpm TSec Va Ia dn/dt
SAMPLE CALCULATIONS:
GRAPHS:
7/30/2019 EM-I manual
31/35
RESULTS AND CONCLUSION:
7/30/2019 EM-I manual
32/35
ELECTRICAL MACHINES LAB-1
EXP -10 : SEPARATION OF LOSSES
AIM : To Separation the losses in a DC shunt motor.
.
NAME PLATE DETAILS:1. voltage :2. current :3. H.P/KW rating:4. speed :
APPARATUS REQUIRED:S.NO Name of the
equipmentRange Type Quantity
CIRCUIT DIAGRAM:
7/30/2019 EM-I manual
33/35
THEORY:
RECAUTIONS:1. Wear the hand gloves.2. Avoid loose connections and hanging wires.3. Make sure the initial value of field resistance is minimum.4. Dont start the motor ON load.
PROCEDURE:
1. make the connection as per the circuit diagram2. Ensure minimum resistance (rheostat in min position) in the field circuit.3. Switch on the supply and run the motor at rated speed by adjusting field rheostat.4. Adjust I f to rated value at no load.5. Reduce the armature circuit resistance in steps, increasing the speed.6. Take the readings of voltmeter, ammeter and speed at constant field current.7. Continue the experiment till maximum speed is obtained by cutting out the
complete resistance in armature circuit (do not exceed rated speed).8. Bring the armature rheostat back to full resistance(initial position).9. repeat the experiment with a reduced field (75%) .
OBSERVATIONS :
At full exciatation:Sno N
RpmVVolts
If Amps
Ia
Amps
V-IaR a=E b
W s=E bIa W s/N
At excitation:Sno N
RpmVVolts
If Amps
Ia
Amps
V-IaR a=E b
W s=E bIa W s/N
7/30/2019 EM-I manual
34/35
GRAPHS:
Plot W s/N vs field excitation
From graphOP=A+CPQ=tan 1=slope of line PQPQ= B+DIf motor runs at different excitation then
OR= A+C 1
RS=tan 2 = slope of line RSRS=B+D 1
C-C 1=OP-OR D-D 1=tan 1-tan 2 =
If B1 max and B2max are flux densities of two different excitations then
6.1
2
1
6.1
2
11 max
max
=
=
EB
EB
B
B
C
C
Where EB 1 and EB 2 are back emf developed in motor at two different excitations then
2
2
1
2
2
11 max
max
=
=
EB
EB
B
B
D
D
C-C 1=OP-OR D-D 1=tan 1-tan 2
7/30/2019 EM-I manual
35/35
A=B=C=D=Hysterisis losses= AN
Eddy current losses=BN2
Friction losses= CNWindage losses= DN2Stray losses= (A=C)N+(B+D)N 2
RESULTS AND CONCLUSION