Post on 23-Jul-2021
Quality of air means quality of life
De
Baa
lje, A
uric
h, G
erm
any
Outstanding corrosion
protection!
Efficient dehumidification and climate control solutions for your swimming pool
Pool Line HANSA is a member of the association of manufacturers for air conditioning devices (Raumlufttechnische Geräte e.V.)
Air Conditioning Systemswww.hansa-klima.com
About us
Our Team
We continuously train our employees in order to educate our team to be well-prepared for the changing needs of the industry. Some staff members have been with us since the founding of the company, other specialists are enriching our staff continuously. The HANSA team consists of experienced experts in the field of air conditioning device production and the associated specialized fields of refrigeration technique, control engineering and control. We have excellent organizational means and state-of-the-art manufacturing machines. The construction and production are performed in QM-conditions according to DIN EN ISO 9001:2008.
Our philosophy
Our goal is to optimally comply with the climate re-quirements of our customers and to contribute to the protection of the environment. We offer therefore sys-tems that can be adapted to the individual operating conditions of the customers at low energy consumpti-on thanks to flexible production processes and up-to-date components. As the energy demand of the over-all system and the individual modules can be reduced without affecting the efficiency of the system, the investment and energy costs will decrease likewise.
Our company, the HANSA Klimasysteme GmbH, was founded in 1971 and is based in Strücklingen in the municipality Saterland that is known to be the tiniest linguistic enclave in Germany for its Saterfrisian dialect. In contrast, we speak in plain language about our products. We have been guaranteeing sophisticated and high-quality air conditioning systems for more than 40 years.
The company
Since the founding of the company, we have been known for the construction of air-conditioning systems for schools, sports halls, swimming pools and hospitals as well as for the use in industries and process engineering in Germany and far beyond. Based on our experience with these systems, we have developed a wide range of air conditioning devices that we are pleased to present in our delivery program.
Our constructive solutions for the continuously increasing of today‘s indoor air quality needs guarantee a constant quality, functionality, and reliability with increasing energy efficiency levels. Many property rights have been registered at the European Patent Office during the development processes and have been considered worthy of patents and protection.
As member of the association of manufacturers for air conditioning devices (RLT Herstellerverbandes e.V.), we undertake to construct our devices according to the associations’ guidelines to always guarantee quality, operational safety and legal security for our customers and operators of our devices.
HANSA site
QM-System
mit SystemPartnerschaft
Sie rechnen
ISO
900
1
EN
-900
1
. . . mit uns können
Pool dehumidification
Why HANSA?
• Benefit from our experience: We have been producing swimming pool dehumidifier units for decades
• Benefit from the durability of our units: Our customers can confirm that they have achieved service lives of several decades despite the units being installed in corrosive atmospheres
• Reduce your operating costs: Our controller expertise in conjunction with energy-efficient components from well-known manufacturers guarantees optimum energy use and therefore low operating costs for these units
Our references speak for us:
The task
Guaranteeing a high level of comfort and protecting health:
• Adequate exchange of fresh air
• Compliance with humidity limits
• Removal of odorous and noxious substances (chlorine / trihalogen methane concentrations)
• Preventing mold growth
• Air/temperature regulation according to requirements
Providing building protection:
• Preventing damp spots on wall and ceiling elements
• Preventing corrosion by adhering to humidity limits
• Preventing excessive diffusion of steam
The challenge
• Maximum energy-efficiency management
• High level of corrosion protection for the unit and all of its components
• Ensuring high availability
The HANSA solution
• Careful selection of high-efficiency components for the unit
• All of the units in our Pool Line series are optimized for their respective application
• HANSA controller, produced in house, with the optimized Pool Line Energy Management System developed over many years of experience
• High-efficiency heat recovery systems
• High level of corrosion protection of all materials and components used
• Only components from well-known manufacturers are used
Complies toregulation(EU) 1253/2014regarding toecodesignrequirements forventilation units
ErPREADY
Pool Line references
3Status 11 / 2017 - Subject to construction modifications
Winter operating mode When outside temperatures are low, the outside/return airflow ratio is reduced to the amount hygienically necessary.
The moisture extraction capacity via the plate heat exchanger is increased by the cold outside air. The heat pump is used in order to further increase dehumidification capacity. The con-densation heat generated by this is fed into the swimming pool via the supply air; excess en-ergy from this process is released to the pool water (optional).
Operation in transition periods (spring/autumn)
Only small transmission losses occur with mod-erate outside temperatures. For moisture extrac-tion, the unit is operated with 100 % outside air and the plate heat exchanger is fully activated for energy recovery. Additional heat demand can be satisfied by the heat pump or the hot water coil.
Summer operating mode
Unlike the previous working condition, as tem-peratures increase, the plate heat exchanger is only charged with an infinitely variable partial airflow. This stops the swimming pool over-heating and guarantees a comfortable climate.
Functional description (example: Pool Line PT with heat pump)
Key:
Outside air Exhaust air Return air Supply air
4
Functional description (example: Pool Line PT with heat pump)
Summer operating mode with a high outside temperature
The swimming pool hall is supplied with pure outside air; heat recovery is not required. The volume of air is regulated on a sliding basis in dependence of the moisture extraction required.
Unoccupied (Rest) operating mode No fresh air feed is necessary during rest operating mode. The volume of air is reduced. The unit ensures that the temperature is main-tained and that sufficient air flows through the swimming pool hall. The humidity of the swim-ming pool hall corresponds to the set points.
Rest dehumidification operating mode
If the humidity set points of the swimming pool hall are not fulfilled in rest operating mode, dehumidification is performed by the heat pump with a reduced volume of air. The reduction in the volume of air simultaneously increases dehumidification capacity. No supply of fresh air is required in rest operating mode.
5Status 11 / 2017 - Subject to construction modifications
Pool Line HKG-PL-P
OAEA SA RA
Length
Summer operating mode Summer operating mode with high outside temperatures
Rest dehumidification operating modeRest operating mode
Winter operating mode Operation in transition periods(spring/ autumn)
P-015 P-023 P-030 P-034
Width [in] 27 35 43 43Height [in] 78.74 78.74 82.68 82.68Length [in] 73.23 73.23 81.5 81.5Weight [lbs] 1 246 1 587 1 885 1 885
P-015 P-023 P-030 P-034
Width [mm] 670 880 1 080 1 080Height [mm] 2 000 2 000 2 100 2 100Length [mm] 1 860 1 860 2 070 2 070Weight [kg] 565 720 855 855
The model features and design parameters displayed here have been configured as an example to adhere to the values which will be introduced by the Ecodesign Directive from 2018 and therefore also to the values of HVAC energy efficiency class A+, without an integrated heat pump. We would be happy to supply a unit optimized to suit your particular application. Talk to us!
2018ErPREADY
Complies toregulation(EU) 1253/2014regarding toecodesignrequirements forventilation units
• Compact units with dual-plate exchangers
• Air flow from 883 CFM to 2 001 CFM
• Private pool up to 1130 sq ftIndoor pool up to 797 sq ftLeisure pool up to 581 sq ftWave pool up to 474 sq ftTherapy pool up to 269 sq ft
• Optionally available with a freely-controllable dehumidi-fying heat pump as well as a pool water condenser / fresh water heater
• Housing design: Highly rigid thermally insulated 1.2 in pro-files with appropriate panel-ling, for indoor installation
• Latest generation EC fans
• Includes unit controller mounted to the side of the unit with optimized operating strategy
6
P-015 P-023 P-030 P-034
Area of application 1)
Private pool m2 / sq ft 44 / 474 67 / 721 88 / 947 105 / 1130
Indoor pool m2 / sq ft 33 / 355 51 / 549 67 / 721 74 / 797
Leisure pool m2 / sq ft 24 / 258 37 / 398 48 / 517 54 / 581
Wave pool m2 / sq ft 19 / 205 29 / 312 38 / 409 44 / 474
Therapy pool m2 / sq ft 11 / 118 16 / 172 21 / 226 25 / 269
Air flow m3/h / CFM 1 500 / 883 2 300 / 1354 3 000 / 1766 3 400 / 2001
Dehumidification capacity 2) kg/h / lb/h 9.7 / 21.4 14.9 / 32.8 19.4 / 42.8 22 / 48.5
Dehumidification capacity 3) kg/h / lb/h 4.8 / 10.6 7.4 / 16.3 9.6 / 21.2 10.9 / 24
Energy recovery
Power 4) kW / MBTU/h 18.2 / 62 28.1 / 96 36.7 / 125 41.5 / 142
Degree of efficiency acc. to DIN EN 308 5) % 77.6 77.4 78.6 78.8
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400
Supply air fan
Electrical system power kW 0.54 0.87 1.13 1.45
Rated motor power kW 0.75 1.05 1.23 1.8
Return air fan
Electrical system power kW 0.51 0.83 1.09 1.38
Rated motor power kW 0.75 1.05 1.23 1.8
Heating coil 6)
Power kW / MBTU/h 8 / 27.3 12 / 41.0 16 / 54.6 18 / 61.4
Heat pump (optional)
Heating capacity kW / MBTU/h 7 / 23.9 10.3 / 31.1 12.5 / 42.7 15.2 / 51.9
Coefficient Of Performance COP 4.6 4.5 4.5 4.6
Sound power level at
Air inlet nozzle dB(A) 80 82 79 85
Air outlet nozzle dB(A) 68 69 70 73
Outside air nozzle dB(A) 58 60 61 63
Exhaust air nozzle dB(A) 71 73 70 76
Electrical connection data at 400 V (with heat pump)
Voltage V 230/400 400 400 400
Connected load kW 5 6.7 7.6 9.6
Power consumption A 9 12 14 18
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7
1) According to VDI 2089 at Twater= 28°C (82.4°F) and Troom= 30°C (86°F) / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, 2/3 rated flow rate, Tinlet= 30°C (86°F) / 54% r.h., with heat pump4) At rated flow rate for Toutside air= -12°C (10.4 °F) / 90% r.h.; Treturn air= 30°C (86°F) / 54% r.h. 5) At rated flow rate for Toutside air= 5°C (41°F) / 10% r.h.; Treturn air: 25°C (77°F) / 10% r.h.6) Air inlet temperature: 18°C (64.4°F); water temperature: 60°C (140°F) / 40°C (104°F)
7Status 11 / 2017 - Subject to construction modifications
Pool Line HKG-PL-PWT
EA OA RA SA
CB
Length
A
Summer operating mode Summer operating mode with high outside temperatures
Rest dehumidification operating mode
Rest operating mode
Winter operating mode Operation in transition periods(spring/ autumn)
PWT-027 PWT-031 PWT-041 PWT-050 PWT-068 PWT-084Width [mm / in] 800 / 32 880 / 32 1 080 / 43 1 280 / 51 1 280 / 51 1 590Height [mm / in] 1 865 / 75 1 865 / 75 1 865 / 75 1 865 / 75 2 140 / 86 2 140Length [mm / in] 3 210 / 128 3 210 / 128 3 210 / 128 3 210 / 128 4 060 / 162 4 060 / 162A [mm / in] 785 / 31 785 / 31 785 / 31 785 / 31 1 030 / 41 1 030 / 41B [mm / in] 1 640 / 66 1 640 / 66 1 640 / 66 1 640 / 66 2 000 / 80 2 000 / 80C [mm / in] 785 / 31 785 / 31 785 / 31 785 / 31 1 030 / 41 1 030 / 41
2018ErPREADY
Complies toregulation(EU) 1253/2014regarding toecodesignrequirements forventilation units
The model features and design parameters displayed here have been configured as an example to adhere to the values which will be introduced by the Ecodesign Directive from 2018 and therefore also to the values of HVAC energy efficiency class A+, without an integrated heat pump. We would be happy to supply a unit optimized to suit your particular application. Talk to us!
• Compact units with air to air heat exchanger, all connec-tions on top
• Air flow from 1 589 CFM to 4 944 CFM
• Private pool up to 2443 sq ftIndoor pool up to 1873 sq ftLeisure pool up to 1335 sq ftWave pool up to 1076 sq ftTherapy pool up to 603 sq ft
• Optionally available with a freely-controllable dehumidi-fying heat pump as well as a pool water condenser / fresh water heater
• Housing design: Highly rigid thermally insulated 1.2 in pro-files with appropriate panel-ling, for indoor installation
• Latest generation EC fans
• Includes unit controller mounted to the side of the unit with optimized operating strategy
8
PWT-027 PWT-031 PWT-041 PWT-050 PWT-068 PWT-084
Area of application 1)
Private pool m2 / sq ft 79 / 850 91 / 980 120 / 1 292 146 / 1 572 200 / 2 153 227 / 2 443
Indoor pool m2 / sq ft 60 / 646 70 / 753 92 / 990 112 / 1 206 152 / 1 636 174 / 1 873
Leisure pool m2 / sq ft 43 / 463 50 / 538 66 / 710 80 / 861 110 / 1 184 124 / 1 335
Wave pool m2 / sq ft 35 / 377 40 / 431 52 / 560 64 / 689 87 / 936 100 / 1 076
Therapy pool m2 / sq ft 19 / 205 22 / 237 29 / 312 36 / 388 49 / 527 56 / 603
Air flow m3/h / CFM 2 700 / 1 589 3 100 / 1 825 4 100 / 2 413 5 000 / 2 943 6 800 / 4 002 8 400 / 4 944
Dehumidification capacity 2) kg/h / lb/h 17.5 / 38.6 20.1 / 44.3 26.5 / 58.4 32.4 / 71.4 44.1 / 97.2 54.4 / 119.9
Dehumidification capacity 3) kg/h / lb/h 8.6 / 19 10.0 / 22 13.1 / 28.9 16.0 / 35.3 21.8 / 48.1 21.8 / 48.1
Energy recovery
Power 4) kW / MBTU/h 32.2 / 110 37.0 / 126 49.0 / 167 59.6 / 203 81.6 / 278 99.9 / 341
Degree of efficiency acc. to DIN EN 308 5) % 74.9 74.9 75.0 75.2 75.5 74.8
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400 400 400
Supply air fan
Electrical system power kW 1.09 1.21 1.52 1.85 2.38 3.00
Rated motor power kW 1.23 1.80 1.90 2.50 2.90 3.45
Return air fan
Electrical system power kW 1.07 1.20 1.50 1.87 2.36 2.98
Rated motor power kW 1.23 1.80 1.90 2.50 2.90 3.45
Heating coil 6)
Power kW / MBTU/h 15.0 / 51.2 17.0 / 58 23.0 / 78.5 30 .0/ 102.4 41.0 / 139.9 50.0 / 170.6
Heat pump
Heating capacity kW / MBTU/h 10.5 / 35.8 12.0 / 41.0 15.0 / 51.2 21.5 / 73.4 30 .0/ 102.4 40.0 / 136.5
Coefficient Of Performance COP 4.9 4.8 5.0 4.7 4.8 5.1
Pool water condensation unit (optional) 7)
Power kW / MBTU/h 10.5 / 35.8 12.0 / 41.0 15.0 / 51.2 21.5 / 73.4 30.0 / 102.4 40.0 / 136.5
Fresh water heater (optional) 8)
Power kW / MBTU/h 1.95 / 6.7 2.23 / 7.6 2.79 / 9.5 4.00/ 13.6 5.58 / 19.0 7.44 / 25.4
Sound power level at
Air inlet nozzle dB(A) 81 85 84 85 85 85
Air outlet nozzle dB(A) 67 66 66 67 67 68
Outside air nozzle dB(A) 67 65 65 66 66 66
Exhaust air nozzle dB(A) 81 85 84 85 85 85
Electrical connection data at 400V (with heat pump)
Voltage V 400 400 400 400 400 400
Connected load kW 7 8 10 13 15 20
Power consumption A 12 15 18 23 27 34
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7
1) According to VDI 2089 at Twater= 28°C (82.4°F) and Troom= 30°C (86°F) / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, 2/3 rated flow rate, Tinlet= 30°C (86°F) / 54% r.h., with heat pump4) At rated flow rate for Toutside air= -12°C (10.4°F) / 90% r.h.; Treturn air= 30°C (86°F) / 54% r.h.5) At rated flow rate for Toutside air= 5°C (41°F) / 10% r.h.; Treturn air: 25°C (77°F) / 10% r.h.6) Air inlet temperature: 18°C (64.4°F); water temperature: 60°C (140°F) / 40°C (104°F)7) Only possible in conjunction with a heat pump. Water inlet temperature: 28°C (82.4°F)8) Only possible in conjunction with a heat pump. Water inlet temperature: 10°C (50°F)
9Status 11 / 2017 - Subject to construction modifications
Pool Line HKG-PL-PT
Summer operating mode Summer operating mode with high outside temperatures
Rest dehumidification operating mode
Rest operating mode
Winter operating mode Operation in transition periods(spring/ autumn)
PT-2 PT-3 PT-4 PT-6 PT-7 PT-9 PT-12 PT-16 PT-18Width [mm / in] 670 / 26 880 / 35 1 080 / 43 1 080 / 43 1 280 / 50 1 590 / 63 1 930 / 76 2 240 / 88 2 440 / 96Height [mm / in] 1 440 / 57 1 440 / 57 1 760 / 69 2 160 / 85 2 160 / 85 2 160 / 85 2 560 / 101 2 760 / 109 3 000 / 118Length [mm / in] 3 260 / 128 3 310 / 130 3 830 / 151 4 510 / 178 4 640 / 183 4 800 / 189 5 570 / 219 6 020 / 237 6 020 / 237A [mm / in] 1 000 / 39 1 050 / 41 1 150 / 45 1 330 / 52 1 460 / 58 1 620 / 64 1 760 / 69 2 010 / 79 2 010 / 79B [mm / in] 1 640 / 65 1 640 / 65 1 960 / 77 2 360 / 93 2 360 / 93 2 360 / 93 2 760 / 109 2 960 / 117 2 960 / 117C [mm / in] 620 / 24 620 / 24 720 / 28 820 / 32 820 / 32 820 / 32 1 050 / 41 1 050 / 41 1 050 / 41
2018ErPREADY
Complies toregulation(EU) 1253/2014regarding toecodesignrequirements forventilation units
• Compact units with air to air plate heat exchanger, connec-tions on side
• Air flow from 971 CFM to 10 594 CFM, no heat pump
• Private pool up to 5705 sq ft Indoor pool up to 4252 sq ft Leisure pool up to 3100 sq ft Wave pool up to 2476 sq ft Therapy pool up to 1389 sq ft
• Optionally available with a freely-controllable dehumidi-fying heat pump as well as a pool water condenser / fresh water heater
• Housing design: Highly rigid, thermally insulated 1.2 / 2.0 in profiles with appropriate pan-elling, for indoor and outdoor installation (weatherproof)
• Latest generation fans
• Includes unit controller with optimized operating strategy
The model features and design parameters displayed here have been configured as an example to adhere to the values which will be introduced by the Ecodesign Directive from 2018 and therefore also to the values of HVAC energy efficiency class A+, without an integrated heat pump. We would be happy to supply a unit optimized to suit your particular application. Talk to us!
SA
RAOA
EA
CB
Length
A
10
US customary units
PT-2 PT-3 PT-4 PT-6 PT-7 PT-9 PT-12 PT-16 PT-18
Area of application 1)
Private pool sq ft 484 807 1 345 1 830 2 153 2 691 3 821 4 898 5 705
Indoor pool sq ft 377 592 969 1 346 1 615 1 991 2 852 3 735 4 252
Leisure pool sq ft 280 431 721 990 1 163 1 464 2 067 2 669 3 100
Wave pool sq ft 226 344 570 797 936 1 163 1 647 2 131 2 476
Therapy pool sq ft 118 194 323 441 517 657 926 1 195 1 389
Air flow CFM 971 1 471 2 472 3 237 4 002 5 003 7 063 9 123 10 594
Dehumidification capacity 2) lb/h 22 35 60 77 97 121 170 220 256
Dehumidification capacity 3) lb/h 15 18 22 33 42 60 88 115 132
Energy recovery
Power 4) MBTU/h 68 102 174 222 300 311 450 638 740
Degree of efficiency acc. to DIN EN 308 5) % 76 75 74.9 73.5 78 76.6 78.3 74.7 74.6
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400 400 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400 400 400 400 400 400
Supply air fan
Electrical system power kW 0.83 1.08 1.61 2.04 2.76 3.35 4.75 6.00 6.86
Rated motor power kW 1.27 1.65 2.25 2.83 2.83 4 5.5 5.5 7.5
Return air fan
Electrical system power kW 0.8 1.06 1.54 1.97 2.53 3.22 4.65 5.81 6.75
Rated motor power kW 1.27 1.65 2.25 2.83 2.83 4 5.5 5.5 7.5
Heating coil 6)
Power MBTU/h 48 72 119 157 194 242 341 444 512
Heat pump (optional)
Heating capacity MBTU/h 25 39 56 82 113 143 184 290 290
Coefficient Of Performance COP 4.5 4.6 4.8 5 4.8 4.9 4.8 4.4 4.7
Pool water condensation unit (optional) 7)
Power MBTU/h 20 31 46 65 92 119 154 188 239
Fresh water heater (optional) 8)
Power MBTU/h 5 9 10 17 20 24 31 34 48
Sound power level at
Air inlet nozzle dB(A) 86 84.3 85 84.3 85.8 85.8 85.7 87.5 88
Air outlet nozzle dB(A) 73.8 79.7 72.6 72.3 73.6 81.6 73.9 75.5 75.7
Outside air nozzle dB(A) 69.9 68 67.7 67.5 68.8 66.9 68.7 70.5 70.2
Exhaust air nozzle dB(A) 81.2 72.9 80.4 79.7 81.1 72 81.3 83.2 83.3
Electrical connection data
Voltage V 230/400 400 400 400 400 400 400 400 400
Connected load kW 6 8 11 14 21 21 29 31 40
Power consumption A 20 16 22 27 38 44 58 61 77
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
1) According to VDI 2089 at Twater= 82.4°F and Troom= 86°F / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, rated flow rate, Tinlet= 86°F / 54% r.h., with heat pump4) At rated flow rate for Toutside air= 10.4°F / 90% r.h.; Treturn air= 86°F / 54% r.h.5) At rated flow rate for Toutside air= 41°F / 10% r.h.; Treturn air: 77°F / 10% r.h.6) Air inlet temperature: 59°F; water temperature: 140°F / 104°F7) Only possible in conjunction with a heat pump. Water inlet temperature: 82.4°F8) Only possible in conjunction with a heat pump. Water inlet temperature: 50°F
11Status 11 / 2017 - Subject to construction modifications
PT-2 PT-3 PT-4 PT-6 PT-7 PT-9 PT-12 PT-16 PT-18
Area of application 1)
Private pool m2 45 75 125 170 200 250 355 455 530
Indoor pool m2 35 55 90 125 150 185 265 347 395
Leisure pool m2 26 40 67 92 108 136 192 248 288
Wave pool m2 21 32 53 74 87 108 153 198 230
Therapy pool m2 11 18 30 41 48 61 86 111 129
Air flow m3/h 1 650 2 500 4 200 5 500 6 800 8 500 12 000 15 500 18 000
Dehumidification capacity 2) kg/h 10 16 27 35 44 55 77 100 116
Dehumidification capacity 3) kg/h 7 8 10 15 19 27 40 52 60
Energy recovery
Power 4) kW 20 30 51 65 88 91 132 187 217
Degree of efficiency acc. to DIN EN 308 5) % 76 75 74.9 73.5 78 76.6 78.3 74.7 74.6
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400 400 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400 400 400 400 400 400
Supply air fan
Electrical system power kW 0.83 1.08 1.61 2.04 2.76 3.35 4.75 6.00 6.86
Rated motor power kW 1.27 1.65 2.25 2.83 2.83 4 5.5 5.5 7.5
Return air fan
Electrical system power kW 0.8 1.06 1.54 1.97 2.53 3.22 4.65 5.81 6.75
Rated motor power kW 1.27 1.65 2.25 2.83 2.83 4 5.5 5.5 7.5
Heating coil 6)
Power kW 14 21 35 46 57 71 100 130 150
Heat pump (optional)
Heating capacity kW 7.4 11.5 16.5 24 33 42 54 85 85
Coefficient Of Performance COP 4.5 4.6 4.8 5 4.8 4.9 4.8 4.4 4.7
Pool water condensation unit (optional) 7)
Power kW 6 9 13.5 19 27 35 45 55 70
Fresh water heater (optional) 8)
Power kW 1.4 2.5 3 5 6 7 9 10 14
Sound power level at
Air inlet nozzle dB(A) 86 84.3 85 84.3 85.8 85.8 85.7 87.5 88
Air outlet nozzle dB(A) 73.8 79.7 72.6 72.3 73.6 81.6 73.9 75.5 75.7
Outside air nozzle dB(A) 69.9 68 67.7 67.5 68.8 66.9 68.7 70.5 70.2
Exhaust air nozzle dB(A) 81.2 72.9 80.4 79.7 81.1 72 81.3 83.2 83.3
Electrical connection data
Voltage V 230/400 400 400 400 400 400 400 400 400
Connected load kW 6 8 11 14 21 21 29 31 40
Power consumption A 20 16 22 27 38 44 58 61 77
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
1) According to VDI 2089 at Twater= 28°C and Troom= 30°C / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, rated flow rate, Tinlet= 30°C / 54% r.h., with heat pump4) At rated flow rate for Toutside air= -12°C / 90% r.h.; Treturn air= 30°C / 54% r.h.5) At rated flow rate for Toutside air= 5°C / 10% r.h.; Treturn air: 25°C / 10% r.h.6) Air inlet temperature: 15°C; water temperature: 60°C / 40°C7) Only possible in conjunction with a heat pump. Water inlet temperature: 28°C8) Only possible in conjunction with a heat pump. Water inlet temperature: 10°C
Metric system
12
Pool Line HKG-PL-DPT
EA
OA
RA
SA
CB
Length
A
The model features and design parameters displayed here have been configured as an example to adhere to the values which will be introduced by the Ecodesign Directive from 2018 and therefore also to the values of HVAC energy efficiency class A+, without an integrated heat pump. We would be happy to supply a unit optimized to suit your particular application. Talk to us!
2018ErPREADY
Complies toregulation(EU) 1253/2014regarding toecodesignrequirements forventilation units
• Units with dual air to air plate heat exchanger and accord-ingly with outstanding degree of efficiency
• Air flow from 1 413 CFM to 23 543 CFM
• Private pool up to 11 141 sq ftIndoor pool up to 8288 sq ftLeisure pool up to 555 sq ftWave pool up to 445 sq ftTherapy pool up to 245 sq ft
• Optionally available with a freely-controllable dehumidi-fying heat pump as well as a pool water condenser / fresh water heater
• Housing design: Highly rigid, thermally insulated 1.2 / 2.0 in profiles with appropriate pan-elling, for indoor and outdoor installation (weatherproof)
• Latest generation fans
• Includes unit controller with optimized operating strategy
Summer operating mode Summer operating mode with high outside temperatures
Rest dehumidification operating mode
Rest operating mode
Winter operating mode Operation in transition periods(spring/ autumn)
DPT-4 DPT-6 DPT-9 DPT-12 DPT-16 DPT-20 DPT-25 DPT-30 DPT-35
Width [mm / in] 880 / 35 1 080 / 43 1 590 / 63 1 280 /51 1 890 / 74 1 890 / 74 2 540 / 100 3 150 / 124 3 150 / 124
Height [mm / in] 1 860 / 73 2 060 / 81 2 060 / 81 2 660 / 105 2 660 / 105 3 280 / 129 3 360 / 132 3 360 / 132 4 040 / 159
Length [mm / in] 6 520 / 257 7 160 / 282 7 500 / 295 8 310 / 327 8 340 / 328 9 040 / 356 9 620 / 379 9 840 / 387 10 890 / 429
A [mm / in] 2 480 / 98 2 580 / 102 2 680 / 106 2 680 / 106 2 680 / 106 2 680 / 106 2 680 / 106 2 680 / 106 2 680 / 106
B [mm / in] 2 320 / 91 2 610 / 103 2 610 / 103 3 310 / 130 3 310 / 130 3 910 / 154 3 970 / 156 4 180 / 165 4 580 / 180
C [mm / in] 1 720 / 68 1 970 / 78 2 210 / 87 2 320 / 91 2 350 / 93 2 450 / 97 2 970 / 117 2 980 / 118 3 630 / 143
PT-2 PT-3 PT-4 PT-6 PT-7 PT-9 PT-12 PT-16 PT-18
Area of application 1)
Private pool m2 45 75 125 170 200 250 355 455 530
Indoor pool m2 35 55 90 125 150 185 265 347 395
Leisure pool m2 26 40 67 92 108 136 192 248 288
Wave pool m2 21 32 53 74 87 108 153 198 230
Therapy pool m2 11 18 30 41 48 61 86 111 129
Air flow m3/h 1 650 2 500 4 200 5 500 6 800 8 500 12 000 15 500 18 000
Dehumidification capacity 2) kg/h 10 16 27 35 44 55 77 100 116
Dehumidification capacity 3) kg/h 7 8 10 15 19 27 40 52 60
Energy recovery
Power 4) kW 20 30 51 65 88 91 132 187 217
Degree of efficiency acc. to DIN EN 308 5) % 76 75 74.9 73.5 78 76.6 78.3 74.7 74.6
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400 400 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400 400 400 400 400 400
Supply air fan
Electrical system power kW 0.83 1.08 1.61 2.04 2.76 3.35 4.75 6.00 6.86
Rated motor power kW 1.27 1.65 2.25 2.83 2.83 4 5.5 5.5 7.5
Return air fan
Electrical system power kW 0.8 1.06 1.54 1.97 2.53 3.22 4.65 5.81 6.75
Rated motor power kW 1.27 1.65 2.25 2.83 2.83 4 5.5 5.5 7.5
Heating coil 6)
Power kW 14 21 35 46 57 71 100 130 150
Heat pump (optional)
Heating capacity kW 7.4 11.5 16.5 24 33 42 54 85 85
Coefficient Of Performance COP 4.5 4.6 4.8 5 4.8 4.9 4.8 4.4 4.7
Pool water condensation unit (optional) 7)
Power kW 6 9 13.5 19 27 35 45 55 70
Fresh water heater (optional) 8)
Power kW 1.4 2.5 3 5 6 7 9 10 14
Sound power level at
Air inlet nozzle dB(A) 86 84.3 85 84.3 85.8 85.8 85.7 87.5 88
Air outlet nozzle dB(A) 73.8 79.7 72.6 72.3 73.6 81.6 73.9 75.5 75.7
Outside air nozzle dB(A) 69.9 68 67.7 67.5 68.8 66.9 68.7 70.5 70.2
Exhaust air nozzle dB(A) 81.2 72.9 80.4 79.7 81.1 72 81.3 83.2 83.3
Electrical connection data
Voltage V 230/400 400 400 400 400 400 400 400 400
Connected load kW 6 8 11 14 21 21 29 31 40
Power consumption A 20 16 22 27 38 44 58 61 77
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
1) According to VDI 2089 at Twater= 28°C and Troom= 30°C / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, rated flow rate, Tinlet= 30°C / 54% r.h., with heat pump4) At rated flow rate for Toutside air= -12°C / 90% r.h.; Treturn air= 30°C / 54% r.h.5) At rated flow rate for Toutside air= 5°C / 10% r.h.; Treturn air: 25°C / 10% r.h.6) Air inlet temperature: 15°C; water temperature: 60°C / 40°C7) Only possible in conjunction with a heat pump. Water inlet temperature: 28°C8) Only possible in conjunction with a heat pump. Water inlet temperature: 10°C
13Status 11 / 2017 - Subject to construction modifications
DPT-4 DPT-6 DPT-9 DPT-12 DPT-16 DPT-20 DPT-25 DPT-30 DPT-35
Area of application 1)
Private pool sq ft 1453 1991 3014 4036 4790 5920 7610 9688 11141
Indoor pool sq ft 1098 1507 2260 2960 3552 4413 5769 7212 8288
Leisure pool sq ft 807 1076 1615 2153 2583 3229 4090 5167 5974
Wave pool sq ft 624 861 1292 1744 2045 2583 3283 4090 4790
Therapy pool sq ft 344 474 710 947 1130 1399 1787 2260 2637
Air flow CFM 2708 3708 5592 7416 8829 11036 14126 17657 20600
Dehumidification capacity 2) lb/h 65 88 133 177 222 266 336 421 505
Dehumidification capacity 3) lb/h 13 18 27 47 66 73 85 106 134
Energy recovery
Power 4) MBTU/h 186 259 381 532 635 781 1003 1252 1532
Degree of efficiency acc. to DIN EN 308 5) % 74.9 76.5 74.2 76 76 79 79 79 80
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400 400 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400 400 400 400 400 400
Supply air fan
Electrical system power kW 1.8 2.26 2 x 1.76 2 x 2.31 2 x 2.73 2 x 3.26 8.27 10.1 13.7
Rated motor power kW 2.68 5.25 2 x 2.5 2 x 3.6 2 x 3.5 2 x 5.7 11 11 15
Return air fan
Electrical system power kW 1.7 2.11 2 x 1.67 2 x 2.16 2 x 2.54 2 x 2.81 6.97 9.68 13.1
Rated motor power kW 2.68 5.25 2 x 2.5 2 x 3.6 2 x 3.5 2 x 3.45 11 11 15
Heating coil 6)
Power kW 35 53 93 115 125 154 200 250 320
Heat pump (optional)
Heating capacity MBTU/h 41 54 92 123 150 167 215 252 293
Coefficient Of Performance COP 4.8 3.9 5 5 5 5 4.8 5 5
Pool water condensation unit (optional) 7)
Power MBTU/h 38 48 82 92 136 160 194 249 290
Fresh water heater (optional) 8)
Power MBTU/h 8 9 16 17 24 31 34 48 55
Sound power level at
Air inlet nozzle dB(A) 83.6 87.1 86.6 88.1 88.3 92.3 85.4 85.4 86.4
Air outlet nozzle dB(A) 72.1 71.3 73.4 73.5 73.4 78.8 75.1 75.1 76.1
Outside air nozzle dB(A) 62.2 61.9 64.3 64.8 64.9 67.7 65.8 65.8 66.8
Exhaust air nozzle dB(A) 74.2 78.8 78 78.8 79.3 78.9 76.8 76.8 77.8
Electrical connection data
Voltage V 400 400 400 400 400 400 400 400 400
Connected load kW 12 17 19 25 27 33 41 43 55
Power consumption A 24 31 36 46 47 56 86 81 102
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
1) According to VDI 2089 at Twater= 82.4°F and Troom= 86°F / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, 2/3 rated flow rate, Tinlet= 86°F / 54% r.h., with heat pump4) At rated flow rate for Toutside air= 10.4°F / 90% r.h.; Treturn air= 86°F / 54% r.h.5) At rated flow rate for Toutside air= 41°F / 10% r.h.; Treturn air: 77°F / 10% r.h.6) Air inlet temperature: 59°F; water temperature: 140°F / 104°F7) Only possible in conjunction with a heat pump. Water inlet temperature: 82.4°F8) Only possible in conjunction with a heat pump. Water inlet temperature: 50°F
US customary units
14
DPT-4 DPT-6 DPT-9 DPT-12 DPT-16 DPT-20 DPT-25 DPT-30 DPT-35
Area of application 1)
Private pool m2 135 185 280 375 445 550 707 900 1035
Indoor pool m2 102 140 210 275 330 410 536 670 770
Leisure pool m2 75 100 150 200 240 300 380 480 555
Wave pool m2 58 80 120 162 190 240 305 380 445
Therapy pool m2 32 44 66 88 105 130 166 210 245
Air flow m3/h 4 600 6 300 9 500 12 600 15 000 18 750 24 000 30 000 35 000
Dehumidification capacity 2) kg/h 29.3 40.1 60.4 80.1 100.5 120.8 152.6 190.8 229
Dehumidification capacity 3) kg/h 5.9 8.1 12.2 21.2 30 33 38.4 48 61
Energy recovery
Power 4) kW 54.6 75.8 111.7 156 186 229 294 367 449
Degree of efficiency acc. to DIN EN 308 5) % 74.9 76.5 74.2 76 76 79 79 79 80
Ext. pressure drop
Outside air - Supply air Pa 400 400 400 400 400 400 400 400 400
Return air - Exhaust air Pa 400 400 400 400 400 400 400 400 400
Supply air fan
Electrical system power kW 1.8 2.26 2 x 1.76 2 x 2.31 2 x 2.73 2 x 3.26 8.27 10.1 13.7
Rated motor power kW 2.68 5.25 2 x 2.5 2 x 3.6 2 x 3.5 2 x 5.7 11 11 15
Return air fan
Electrical system power kW 1.7 2.11 2 x 1.67 2 x 2.16 2 x 2.54 2 x 2.81 6.97 9.68 13.1
Rated motor power kW 2.68 5.25 2 x 2.5 2 x 3.6 2 x 3.5 2 x 3.45 11 11 15
Heating coil 6)
Power kW 35 53 93 115 125 154 200 250 320
Heat pump (optional)
Heating capacity kW 12 15.75 27 36 44 49 63 74 86
Coefficient Of Performance COP 4.8 3.9 5 5 5 5 4.8 5 5
Pool water condensation unit (optional) 7)
Power kW 11 14 24 27 40 47 57 73 85
Fresh water heater (optional) 8)
Power kW 2.3 2.7 4.6 5 7 9 10 14 16
Sound power level at
Air inlet nozzle dB(A) 83.6 87.1 86.6 88.1 88.3 92.3 85.4 85.4 86.4
Air outlet nozzle dB(A) 72.1 71.3 73.4 73.5 73.4 78.8 75.1 75.1 76.1
Outside air nozzle dB(A) 62.2 61.9 64.3 64.8 64.9 67.7 65.8 65.8 66.8
Exhaust air nozzle dB(A) 74.2 78.8 78 78.8 79.3 78.9 76.8 76.8 77.8
Electrical connection data
Voltage V 400 400 400 400 400 400 400 400 400
Connected load kW 12 17 19 25 27 33 41 43 55
Power consumption A 24 31 36 46 47 56 86 81 102
Filters
Exhaust air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
Outside air filter (DIN EN 779) Class F7 F7 F7 F7 F7 F7 F7 F7 F7
1) According to VDI 2089 at Twater= 28°C and Troom= 30°C / 54% r.h., based on the surface of the water2) According to VDI 2089 at rated flow rate3) Recirculated air, 2/3 rated flow rate, Tinlet= 30°C / 54% r.h., with heat pump4) At rated flow rate for Toutside air= -12°C / 90% r.h.; Treturn air= 30°C / 54% r.h.5) At rated flow rate for Toutside air= 5°C / 10% r.h.; Treturn air: 25°C / 10% r.h.6) Air inlet temperature: 15°C; water temperature: 60°C / 40°C7) Only possible in conjunction with a heat pump. Water inlet temperature: 28°C8) Only possible in conjunction with a heat pump. Water inlet temperature: 10°C
Metric system
15Status 11 / 2017 - Subject to construction modifications
Certified qualityWe use design software and the corresponding components certified by TÜV Süd, in order to provide our customers with ecologically and eco-nomically optimized solutions.
Various certificates and test reports by external institutes confirm that we comply with all relevant standards and guidelines.
In commercial and technical terms, we demonstrate our reliability as a partner to our customers through the use of our QM system, which in-cludes all of the company processes.
HANSA is able to provide certification according to UL for the USA and Canada, if needed
Our standard
E309358
INSTITUT FÜR LUFTHYGIENE Luft und Wasser: Planung, Analysen, Sanierungskonzepte
ILH BERLIN
Zertifikat
Hygiene – Konformitätsprüfung
Geprüftes Baumuster Zentrallüftungsgerät HKG siehe Anlage 1
Auftraggeber / Hersteller HANSA Ventilatoren und Maschinenbau Neumann GmbH, Stockweg 19, 26683 Saterland / Strücklingen, Deutschland
Prüfdatum /-ort 07. – 08.10.2013, HANSA Ventilatoren und Maschinenbau Neumann GmbH, Stockweg 19, 26683 Saterland / Strücklingen, Deutschland
Prüfingenieure Dr.-Ing. M. Möritz, Dipl. Ing. (FH) Jacob Kornack
Im Rahmen der Hygiene-Konformitätsprüfung wurden die hygienerelevanten Anforderungen* der nachfolgend mit „“ markierten Regelwerke geprüft:
Prüfkriterien
Allgemeine Raumlufttechnik
VDI 6022, Blatt 1 (04/2006)
SWKI VA104-01 (04/2006)
VDI 3803 (02/2010)
ÖNORM H 6021 (09/2003)
DIN EN 13779 (09/2007)
Krankenhausbereich
DIN 1946-4 (12/2008)
SWKI 99-3 (03/2004)
ÖNORM H 6020 (02/2007)
Prüfergebnis Die Konformität des geprüften Baumusters mit den hygienerelevanten Anforderungen der o. g. Regelwerke wird bestätigt.
Gültigkeitszeitraum 5 Jahre: 06.2014 – 06.2019
Registriernummer HKP 10/13 - 02
Dipl.-Ing. (FH) J. Kornack ausgestellt am 03.06.2014, Berlin* Regelwerke bzw. Anforderungen aus Regelwerken, auf die in den zu dieser Hygiene-Konformitätsprüfung (HKP) herangezogenen Regelwerken verwiesen wird, wurden nicht berücksichtigt. Die HKP beinhaltet keine toxikologischen Prüfungen oder Bewertungen der in dem geprüften Baumuster eingesetzten Materialien. Dieses Zertifikat einschließlich seiner Anlagen darf nur in vollständiger Form vervielfältigt, verbreitet und/oder zugänglich gemacht werden. Eine Vervielfältigung, Verbreitung und/oder Zugänglichmachung ohne Anlagen oder in Auszügen oder sonst in unvollständiger Form bedarf der Zustimmung des Instituts für Lufthygiene (ILH) Berlin. Alle Rechte, wie insbesondere Urheber- und Leistungsschutzrechte, bleiben im Übrigen vorbehalten.
S. 1 von 12
16
References
Four PT dehumidification units up to 23 543 CFM, ret-rofitting of two heat pumps, ventilation unit for ancillary rooms
Source: Nordseebad Carolinensiel-Harlesiel GmbH,
Fotograf Ulrich Hoppe
Two PT dehumidification units up to 14 714 CFM, ventilation
units for ancillary rooms and roof-mounted unit
Source: Stadt Aurich
Two PT dehumidification unit up to 29 429 CFM, various
ventilation units for ancillary rooms including kitchen
and sauna
Five PT dehumidification units with heat pumps up to 23 543 CFM, multiple roof-mounted units with adiabatic spray humidification as well as smaller ventilation units
Aquadrom Ruda Śląska, PL
Les Thermes water park, LU
Nordseebad Cliner Quelle, Carolinensiel
De Baalje family and wellness baths, Aurich
17Status 11 / 2017 - Subject to construction modifications
Other products in our portfolio
Three ventilation units with hygroscopic rotors have been mounted in the
former AWD headquarters exactly in the wings of the building (inset bottom left, blue elements). Overall, a ventilation capacity of 170 687 CFM was installed.
Custom ventilation and air conditioning equipmentUpon customer request, we can produce high-grade, custom ventilation and air conditioning equipment for a wide range of applications. Our HVAC systems are designed with a pro-gram certified by TÜV Süd and labelled according to their energy efficiency rating.
Blue Line catalog
HKG-K-GP Kompakt Line air handling units
Ready for operating ventilation units with counter-current heat exchanger and DDC up to 942 CFM and 400 Pa exter-nal pressure for installation in suspended ceilings.
Kompakt Line catalog
HKG-P / P-iK Kompakt Line ventilation and complete air conditionersThe P-series air conditioning units are ideal for use in confined spaces because they have a very small footprint, overhead duct connections and DDC. They provide air flow of up to 2 001 CFM, external pressure of 400 Pa and highly efficient heat recovery with a dual-plate exchanger (cross-counter current).
Kompakt Line catalog
LF-Hy high pressure and filtration systems for fresh produce departments A reliable system solution: Turnkey equipment with com-plete production control system and perfect production of the air curtain using slot rails made of aluminium (variable length). Our systems meet the stringent Regulation (EC) No. 852/2004 requirements for hygiene and the DIN 10505 re-quirements in an exemplary manner. These systems have been installed for years, and proven their worth thousands of times over. Each device can supply a counter length of up to 82 ft.
LF-Hy Series catalog
An HKG-P-034 ventilates the new laboratory building of the Fraunhofer Institute in Ilmenau.
HANSA LF-Hy high pressure and air curtain systems for fresh produce counters offer compact, reasonably-priced and efficient system solutions which satisfy DIN 10505, as are used for example in the eat happy sushi bars.
18
Blue Line Hy hygiene devices in health careIn addition to our DIN EN ISO 9001:2008 certified Quality Man-agement System, numerous certificates and reports attest to our high-quality and efficient equipment (e.g. TÜV: meets VDI 3803; ILH Berlin: in compliance with DIN 1946 , page 4, and VDI 6022) the quality of our climate control solutions in the health care industry.
Blue Line Hy catalog
Slim-Line compact heat dissipation unitsHeat dissipation units for telecommunications facilities, data centres, server rooms and control rooms, etc. Energy-opti-mised and highly compact units with free and mechanical cooling, on request in VDI 6022 version. Our slim-line de-vices have a DDC that allows the creation of redundant cool-ing and integration into your BMS (Modbus, BACnet, S-Bus).
Slim Line catalog
Free Line heat dissipation units
Freely configurable heat dissipation units with free and me-chanical cooling, optionally available with humidifier and heater coil for plant rooms and data centres.
Free Line catalog
In the Heart Centre Leipzig, several Blue Line Hy units provide health and standards-compliant ventilation of the stations, etc.
More than 8,000 HANSA HVAC systems with a mechan-ical cooling capacity that is between 24 and 427 MBTU/h and with air flows of at least 883 CFM have been built and installed for Deutsche Telekom.
Heat dissipation of the DolWin 3 converter station, 4 Free Line units with air flow of 29 429 CFM, cooling capacities of 1092 MBTU/h and integrated electric fan heaters.
HANSA Products
19Status 11 / 2017 - Subject to construction modifications
HANSA Air Conditioning Systems Corp. 5333 Oakwood Drive North Tonawanda, NY 14120 +1 716 625 8615 +1 716 710 5440 aaron.wendt@hansa-klima.com www.hansa-klima.com
www.hansa-klima.de/en/sales/national
www.hansa-klima.de/en/sales/international
Find your contact:
HANSA Climate Systems
Office North/StadeOffice North/Butjadingen
Office North/BielefeldOffice East/Potsdam
Office West/Mönchengladbach
Office West/Dülmen
Office West/Waltrop
Head Office / Saterland
Office South-West/St. Ingbert
Office Central/Giessen
Office South/Nürnberg