COCO22 Heat pump Kick Off MeetingThe Natural Refrigerant, The Natural Choice
22 April 2008
SANYO Air Conditioners Europe Kjell Lundén
Maarud gård, Norge
Looking at the house you have to consider:
• Which year the house was built and ev. improvements
• Number of residents
• Living area (heated area)• Energy consumption
• Plot of land and its location
Windows
2-glass windows
Standard 3-glass windows
Energy effective 3-glass windows
-5°
+5°
0°
-10°
-15°
Where goes the energy?
Outer walls 15%
Floor & Basement 15%
Windows 25%
Roof 15%
Ventilation 30%
Old plankhouse with extreme highenergy consumption
Outer walls U=1.0
Base U=1.0
Windows U=3.0
Roof U=0.5
Usage of energy
Household electricity
5000 kWh/year
Heating of the house
15000 kWh/year or around 60%
Hot water
5000 kWh/year
Energy for heating / year
-30°
50 100 150 200 250 300 350
Days
Maximum power requirement at lowest temperature
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 60% of the highest power requirment
T e m p e r a t u r e / e f f e c t
Kostnadseffektivitet
• - 1990: Vedeldning
• 1990 - 2005: Bergvärme
• 2005 - ? : Sanyos CO-2 teknik
Borrhål
• Tidigare energiförbrukning ska kunna motsvaras av värmepumpen.
• Viktigt att kunden håller en så låg framledningstemperatur som möjligt.
• Fler radiatorer eller luftkonvektor sänker framledningstemperaturen.
• Tumregel: Framledningstemperaturen bör aldrig överstiga 50°C, för optimal besparing.
• Rekommendera alltid markstativ.
Att tänka på
Plumbing 01 Sanyo CO2 Eco02 Mixing valve, automatized03 Circulation pump, radiator system04 Adjustment valve for radiator coils05 Radiators06 Radiator thermostatic valves07 Shut off valve for the radiator system08 System/boiler pressure,install on the return pipe09 Expansion vessel, closed(recommended)10 Expansion vessel, open (alternative)11 Filling valve for radiator system12 Safety valve (factory mounted)13 Safety valve for hot water coil14 Mixing valve for hot water15 Non-return valve for incoming cold water16 Taps17 Incoming cold water18 Load circulation pump19 Insulated pipes20 Flexible houses21 Heat pump unit22 Shut-off valves23 Drain valve
Installation of systems with radiators
TankUnit
Mix.V
Radiator
Outdoor IndoorHP Unit
597
931
12
30
Water Supply
Heatingcircuit
Circulationbetween HP and tank
Installation of systems with radiators and floor heating
TankUnit
Mix.V
Radiator
ND10
OutdoorIndoor
HP Unit
597
931
12
30
Water Supply
Heatingcircuit
Circulationbetween HP and tank
Floor heatingMix.V
?????????
Övre skiktplåt
Nedre skiktplåt
Returledning tillNedre skikt
Till VP ifrånNedre skikt
Ifrån VP tilltankensmellanskikt
Tank structure
Domestic cold water inlet (Ø22 mm out)
Domestic hot water outlet (Ø22 mm out)
Waste water pipe connection (Ø22 mm in)
Expansion pipe connection (DN 20 in)
Primary flow out connection (Ø22 mm in)
Primary flow return connection (Ø22 mm out)
Lifting device (DN 20 in). Not a water connection.
From heat pump. Connection (Ø22 mm out)
To heat pump. Connection (Ø22 mm out)
Tank Structure 2
Limitations
Pipe maximum length 15 m
Limitations
Rörchema
Electric box
Electronic
PCB
Electronic
PCB
Main power
supply
connectors Lower
electrical
immersion
heater Cable intake
Cable fixing
Cable fixings
Electrical parts
Wiring
Wiring
Wiring
Connections
Elinkoppling
PANEL
CO2 ECORUM 21 °C (21.5 °C)Tanktemp. 50 °CUte temp. 3 °CStatus:Måndag 20:45Manuell avfrostning Nej
Display normalläge
LoggDiagnosInställningarInställningar kodadManuell drift(Inställning tid)
Huvudmeny
Total drifttid 15351 hTotal kompressor 7350 hKompressor/24 h17:32 hStart komp./24 h 2Senast larm:1. Utegivare2. -3. -
Meny Logg
Kompr effekt 82 HzElpanna 0 kwElpanna temp (55°C) 55°CEl nedre 0 kWEl nedre temp 45°C Rumstemp (21,5 °C) 21 °CUtetemp 3 °CTanktemp (50 °C) 44 °C Radiator temp (40 °C) 40 °C
Meny Diagnos sid 1
Ström (25A) 12AShuntventil +Laddpump 99%VP vatten in 37 °CVP vatten ut 55 °CKompr temp 90 °C Utetemp VP 1 °CFördröjn. El Ej aktiv
Meny Diagnos sid 2
Kommunikation OK
Program ID XXXXXXXProgram datum XX-XX-XX
Meny Diagnos sid 3
Språk SweVärmepump JaHuvudsäkring 20 AFördröjning elpanna 3 hElpanna 50 °C Max elpanna 6 kwEl nedre 45°CMax el nedre 6 kW
Meny Inställningar sid 1
Sommargräns 17°CRumsgivare JaMax framledning 55 °CMin framledning AvHuskurva 50 °CJustering Huskurva 0 °C Temp sänkning NejRum / Framl ändras 0 °C
Meny Inställningar sid 2
TiderMåndag ▲06▼--▲--▼22Tisdag ▲06▼--▲--▼22Onsdag ▲06▼--▲--▼22Torsdag ▲06▼--▲--▼22Fredag ▲06▼--▲--▼22Lördag ▲06▼--▲--▼22Söndag ▲06▼--▲--▼22
Meny Inställningar sid 3
Kod 276Tank Max 65 °CTank Min A 43 °CTank Min B 50 °CTank min gräns 5 °CMin Pump hast 10%Diff Start / Stopp 5 °C Frysgräns 2 °C
Meny Inställningar kodad 276
Värmepump ( )Pumphast 0%Relä 1.5( ) 3( ) 4,5( ) 6( ) 7,5( ) 9( )
Relä nedre 3() 6()
Shuntventil ( )Rumsgivare fel ( )
Meny Manuell
Inställning Tid
MåndagTimme 00:Minut 00:
Meny Inställning tid
Let’s go with the natural choice!Let’s go with the natural choice!