Post on 15-Sep-2020
≤ 0.04”(1mm)
Cat 6 UTP Field Plug Termination
2
Tools
3 4
Remove center spline ifapplicable
Flush Cutters Crimp tool(p/n: PT-908)with 3-slot die:(p/n: PT-DIE2-8)
Jacket Strip tool(p/n: CPT-RGTP)or equivalent
PlugBody
OptionalBoot
PairIsolator
5
Remove Jacket
~ 2 in. (51 mm)
6
1
≤ 0.04” (1mm)
LoadBar
Slide onoptionalboot ifbeing used
Insert Isolator (notched side away from jacket)
[T568Bwiringshown]
Untwist and flatten pairdown to isolator Trim ends clean 7
Insert into load bar withbrown pair on right and lipside of bar up as shown
8
[T568B] [T568A]
Trim flush with load bar
≤ 0.04”(1mm)
Cable O.D. ≤ 0.25”(6.4 mm)
Category 6 UTP23-26 AWG solid or stranded, conductorinsulation 0.037” – 0.042” (.94 – 1.07mm)
Brown conductor(pin 8)
Wh
ite-
Ora
ng
eO
ran
ge
Wh
ite-
Gre
enB
lue
Wh
ite-
Blu
eG
reen
Wh
ite-
Bro
wn
Bro
wn
Ora
ng
eP
air
Blu
eP
air
Gre
enP
air
Bro
wn
Pai
r
[T568B shown] [T568B shown]
[T568A]
Wh
ite-
Gre
enG
reen
Wh
ite-
Ora
ng
eB
lue
Wh
ite-
Blu
eO
ran
ge
Wh
ite-
Bro
wn
Bro
wn
Gre
enP
air
Blu
eP
air
Ora
ng
eP
air
Bro
wn
Pai
r
Cat 6 UTP Field Plug Termination
10
If using boot, slide intoplace prior to crimping
1
2
Optional Boot
11
Fully insert assembly intocrimp tool and squeezehandles until they release.!
OR
(non-booted version)
12Finished Assembly
Pin#’s1 2 3 4 5 6 7 8
©2
01
9S
iem
on
Re
v.B
03
/19
10
0.2
6236
.00
To assist safe installations, comply with the following:A. Use caution when installing or modifying telecommunications circuits.B. Never touch uninsulated wire terminals unless the circuit has been disconnected.C. Never install this device in a wet location.D. Never install wiring during a lightning storm.
Lors de l'installation, respectez les consignes de sécurité suivantes:A. Utiliser avec prudence lors de l'installation ou de la modification circuits detélécommunications.B. Ne jamais toucher les bornes de fil métallique non isolés sauf si le circuit a été débranché.C. Ne jamais installer cet appareil dans un endroit humide.D. Ne jamais installer pendant un orage.
www.siemon.comTo ensure you have the latestrevision to this document, please visit:
Use 3-slot die(p/n: PT-DIE2-8)
9
Insert fully into plug body
Min. jacket depth:0.2” (5.1mm)