Installation InstructionsBulletin 1585BP UTP Plug
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.Refer to the product catalog pages for additional information.
Cut the rip cord asclose to the jacket as
possible. Fan pairs intoproper color code (see nextframe).
Using a cable stripper,remove approximately
38 mm (1.5 in.) of sheath-ing.
3 4
Place modular plugover wire ends being
sure to maintain color code.Insure that the pairs are in-serted all the way into themodular plug including theinner jacket. The inner jack-et should be directly underthe plug’s strain relief tab.
7 8 Using a crimp tool(1585A--JCRIMP),terminate the modularplug to the cable.
Product includes: flexnut, plug assembly,
and modular plug.
1 Place plug housingover the industrial
cable as shown, flex nutmay need to be loosened.
2
Note:Outer cablediameter range 4…8 mm(0.160…0.315 in.)
5 6
T568AColor Code
T568BColor Code
Color Key:1=White/Green2=Green3=White/Orange4=Blue5=White/Blue6=Orange7=White/Brown8=Brown
Color Key:1=White/Orange2=Orange3=White/Green4=Blue5=White/Blue6=Green7=White/Brown8=Brown
= Tip = Ring
1 82 3 4 5 6 7
Pair 3 Pair 1 Pair 4
Pair 2
1 82 3 4 5 6 7
Pair 1 Pair 4Pair 2
Pair 3
After fanning pairs toproper color code,
hold the pairs close to thejacket and trim conductorsleaving 12 mm (0.5 in.) ex-tending from the inner jack-et.
12 mm(0.5 in.)
Insert the modularplug into the plug
housing. Align the latch withthe LATCH slot, depresslatch and insert plug intoplug housing until it bottomsout.
Slide the plug housingup the cable and align
with the modular plug.
9 10
2
PN--26346Printed in USA
The original dustcover (1585BP--MCAP) can be usedto insure properseating of plug.
11 12 While maintainingpressure on plug or
keeping dust cap engaged,tighten the flex nut to0.5 N•m (5 in•lbs).
Place optional dustcap (1585BP--MCAP)
chain over plug housing andposition between flex nutand plug assembly asshown. Tighten chain tosecure.
13
ATTENTION: To assist safe installation, complywith the following:
A. Use caution when installing or modifyingtelecommunications circuits.
B. Never touch uninsulated wire terminalsunless the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
IP67 rating can only be achieved when usingan IP67 rated enclosure with a properly assembledindustrial outlet or industrial plug cap.