Post on 09-Apr-2015
Broadband Multiplay Project
Basic Configuration Guide for OCLAN Switch
v 3.0
HCL Infosystems Ltd.
This document contains proprietary information of HCL Infosystems Ltd. No part of this document may be re-produced, stored,copied, or transmitted in any form or by means electronic, mechanical, photocopying or otherwise, without the express consentof HCL Infosystems Ltd. These services are provided by HCL Infosystems Limited – System Support Organisation –InfoStructure Services under the controls established by a quality management system that meets the requirements of ISO9001:2000 which has been independently certified by BVQI under certificate number: 131026
CONFIDENTIAL
Page 2 of 11Basic Configuration Guide for OCLAN Switch v3.0
OCLAN SWITCH
Unit/Component introduction
SWITCH : ZXR10 T64GOEM : ZTE Corporation
Control Switching Board
The Control Switching Board (MCS) is the core of ZXR10 T64G, implementing the
functions of control module and switching module. It performs the function of
master/slave switchover.
Interfaces Available: Console Interface and 10/100 base TX Ethernet Interface.
Line Interface Cards
The Line Interface cards include Fast Ethernet Interface board, Gigabit Ethernet
Interface board and 10giga bit Ethernet board.10 GB Ethernet is not being used in
BSNL currently.
CONFIDENTIAL
Page 3 of 11Basic Configuration Guide for OCLAN Switch v3.0
44 FE + 4 GE Interface Board
44FE + 4GE Interface card board provides 44 Fast Ethernet Optical
Interfaces and 4 gigabit Ethernet electrical Interfaces.
24 port Gigabit Ethernet Interface Board
This provides 4 gigabit Ethernet Electrical Interfaces and 20 Ethernet Optical
Interfaces.
Line Interface Cards Used
2 * 44FE + 4GE Interface card
1 * 24 GE Interface Card
Ports Used in BSNL currently
GE Interfaces populated with SFPs : 17 nos
FE Interfaces populated with SFPs : 16 nos
ROLE OF OCLAN SWITCH
CONFIDENTIAL
Page 4 of 11Basic Configuration Guide for OCLAN Switch v3.0
OCLAN Switches which becomes the Tier 2 component of the network resides in the
Access layer. OCLAN switches aggregate the number of DSLAMs in every OC cities
as required in the project.
Rack Layout
Note:
1. PDP should be fixed at the front side of Rack and should be at the TOP.
2. Between PDP and OCLAN Rack there should be 2U gap.
Power Cabling:
1. Power cable and Lugs for OCLAN is shipped along with the equipment and
connect it accordingly and on PDP side crimp the –ve with point type lug
and other two ( +ve and ground ) with round type.
CONFIDENTIAL
Page 5 of 11Basic Configuration Guide for OCLAN Switch v3.0
CONTROL AND LINE INTERFACE CARD INSERTION RULE
Note: Each Slot in the slot numbered from 1 to 6 from top of the switch has to
be populated with appropriate cards as shown in the figure above.
SFP MODULE INSERTION RULE
As described in the above figure, slot 1 and slot 2 populated with 44 FE
+ 4 GE card will be inserted with the following SFP modules.
4 GE SFPs in port numbered 45, 46, 47 and 48
8 FE SFPs in port numbered 1, 2, 3, 4, 5, 6, 40 and 41
Port 40 to be configured for Uplink.
Port 41 is reserved for Uplink
All other ports mentioned above to be configured for connecting
DSLAMs
Slot 5 populated with 24 GE card will be inserted with the following SFP
modules.
9 GE SFPs in port numbered 5, 6, 7, 8, 9, 10, 11, 12 and 13
CONFIDENTIAL
Page 6 of 11Basic Configuration Guide for OCLAN Switch v3.0
Fiber Cabling Details
Slot no Card Type Port no SFP/XFPType
Fiber Cable Type Connecting to
1 to 6 FE SFP LC-FC Multimode DSLAM via BSNLprovided Converters
40,41 FE SFP LC-FC MultimodeT1 via UT Starcom
supplied STM Converter1 44 FE + 4 GE
45 to 48 GE SFPLC-FC
Singlemode DSLAMs
1 to 6 FE SFP LC-FC MultimodeDSLAM via BSNL
provided Converters
40,41 FE SFP LC-FC MultimodeT1 via UT Starcom
supplied STM Converter2 44 FE + 4 GE
45 to 48 GE SFPLC-FC
Singlemode DSLAMs
5 24GE 5 to 13 GE SFP LC-FCSinglemode
DSLAMs
Optical Power Range for Transceivers in OCLAN Switch
Tx Optical Power Rangein dBm
Rx Optical Power Rangein dBmTransceiver Type Fiber Type
Min Max Min Max
GE SFP SMF -5 2 -22 -3
FE SFP MMF -9.5 -3 -17 0
Note:
Use 0 dB attenuators for GE Transceivers.
For FE Transceivers, use attenuators of appropriate dB so as to attain Optical
Power within the given range, preferably towards the Rx Minimum value.
CONFIDENTIAL
Page 7 of 11Basic Configuration Guide for OCLAN Switch v3.0
Connecting to ZXR10 T64G
Via Console port:
Connect the PC’s serial port and OCLAN switch’s Console port in the Control
Switching module.
Note: Before Powering on, connect the Console and capture all the logs.
Goto All Programs
Accessories
Communications
HyperTerminal
And set the following parameters as shown after selecting the appropriate COM port.
Bits per sec : 115200Data bit : 8Parity : noneStop bit : 1Flow control : none
CONFIDENTIAL
Page 8 of 11Basic Configuration Guide for OCLAN Switch v3.0
After successful connection establishment capture the logs:
Go to
Transfer
Capture text
In this specify the folder to which the file is to be stored.
Then power ON the system.
After capturing the first boot log you will be getting a prompt as follows
You will enter to the user mode now directly after successfully log intosystem
Prompt : ZXR10> In the User Mode, you may
View simple info Use ping command etc..
Input “enable” command to enter the privilege mode.
Password to enter privilege mode: zxr10
Prompt : ZXR10# The system parameters can be displayed and configured in Privilege
(Enable) Mode Relevant Commands
show running-config show ip route show interface
Input “configure terminal” command to enter the privilege mode.
Prompt : ZXR10(config)# You are able to implement system configuration in Global (Terminal)
Mode
SUMMARY
User mode ZXR100>Privilege mode ZXR100#Global mode ZXR100(config)#
CONFIDENTIAL
Page 9 of 11Basic Configuration Guide for OCLAN Switch v3.0
CONFIGURATION TASKS
Set a username and password for Telnet Access.
ZXR100 (Config)#Username <name> password <password>
Username : bbmp
Password : bbmp123
Configure ip address of management port .
ZXR100(Config)# nvram mng-ip-address <ip address>
IP address: 192.168.1.1
Now OCLAN Switch is ready for access via telnet.
Setting TIME for the System
To set the system time use the command “clock set” in the enable
mode (privilege mode) as given below
ZXR100#clock set <hh:mm:ss>
Setting NAME for the System
To set the system name use the command “hostname” in global
configuration mode.
ZXR100(config)#hostname <system name>
System name to be given as per standard naming conventions as
follows.
AAA-BBB-ccccc-<ID>,
where AAA denotes the location code as per NIB Naming Scheme
BBB denotes the Device Type i.e. LSW
Ccccc (3-5 characters will be used) denotes the function type here it
is OCLAN- OCT2.
ID denotes integer ID ex: 01,02 .
For Ex : OCLAN Switch in Bangalore to be configured as
BGL-LSW-OCT2-01
CONFIDENTIAL
Page 10 of 11Basic Configuration Guide for OCLAN Switch v3.0
PORT CONFIGURATION FOR UPLINK
Slot 1: Port no: 40
1) Login to the system using proper credentials
2) Input enable command in the user mode
ZXR100>enable
3) Input configure terminal command in the privilege mode
ZXR100#configure terminal
4) Create VLAN using following commands
ZXR100#vlan database
ZXR100(vlan)#vlan <vlan-id> [name <vlan-name>]
5) Assigning IP address to the Uplink Port
ZXR10#configure terminal
ZXR10(config)#interface vlan <vlan-id>
ZXR10(config-if)#ip address <ip-address> <netmask>
IP address and mask to be intimated later from NOC, Bangalore
6) Port Configuration.
ZXR100(config)# interface fei_1/40
ZXR100(config-if)#no shutdown
ZXR100(config-if)#negotiation auto
ZXR100(config-if)#switch port mode hybrid
ZXR100(config-if)#switchport hybrid vlan <vlan-id> untag
Vlan-id to be intimated later from NOC, Bangalore
PORT CONFIGURATION FOR REDUNDANT UPLINK
Slot 2 : Port no: 40
Follow the configuration steps as above
Only changes to be made on port number as fei_2/40. Corresponding vlanid and IP
address change will be intimated as and when required.
CONFIDENTIAL
Page 11 of 11Basic Configuration Guide for OCLAN Switch v3.0
FOR CONNECTION TO DSLAMS
Configure the respective ports using the above procedures for vlan-id creation,
Assigning of vlan-ids to the particular port, assigning of ip addresses etc.
Note: Primary GE link from OCLAN to DSLAM will be connected to SFP GE
ports available in the slot 5 of OCLAN.
Redundant GE link from OCLAN to DSLAM will be connected to SFP GE
ports available in slot 1 or slot 2(port 45 to 48 in both slot 1&2).
If the link to DSLAM is FE, primary link will be from slot 1(port 1 to 6) and