Ang Kian Seng - The Next Challenge - Greening Existing Buildings in SG

Post on 09-May-2015

1.133 views 0 download

description

Presentation by Ang Kian Seng titled "The Next Challenge - Greening Existing Buildings in SG"

Transcript of Ang Kian Seng - The Next Challenge - Greening Existing Buildings in SG

Ang Kian SengGroup Director, ResearchExecutive Director, BCA Centre for Sustainable Buildings

The Next ChallengeGreening Existing

Buildings in Singapore

Why Green our Built Environment?

End-Use Electricity Consumption in Singapore (2005)

BCA Green Mark Scheme

Estimated Energy Savings 10% to 15% 15% to 25% 25% to 30% > 30%

Singapore Green Building Roadmap at a glance

Envelop Thermal Transfer Value (ETTV)

CP24:1999 EE Standard for Bldg Services and equipment

2005(green buildings)

80’s – 2005(Energy conservation)

Energy Efficient Building Awards (Oct 2001 to 2005)

2006 - 2007

Offered $20 million cash incentives

$50 million R&D funds

Govt to take lead in green buildings

Legislation (for new and MR bldgs)

Comprehensive industry training

Public outreach

2009

Offered $100million cash incentives

Govt to take stronger leaderships

Offered bonus Gross Floor Area

Higher energy standard

Singapore – Green hub in region

Imposing Minimum Standards on Environmental Sustainability

All New Buildings and Existing Buildings undergoing major

retrofitting works (with GFA ≥ 2000 m2) to meet at least GM -Certified

Standard (April 2008)

Green Mark Building Projects in Singapore

FY05 FY06 FY07 FY08 FY09 FY10 FY11 FY120

200

400

600

800

1000

1200

1400

11 2596

201

367

625

10191110

6 8 31 38 60 111161 164

17 33127

239

427

736

11801274

NB - Cumulative EB - Cumulative

Barriers to greening existing building

Awareness & Knowledge

Capacity

Lack of confidence

Financing

Training and Capacity Building- Green Collar workforceTraining and Capacity Building- Green Collar workforce

2700 attended Green Mark

Manager Course

540 attended Green Mark

Facilities Manager Course

190 attended Green Mark Professional

Course

>200 Certified Singapore

Certified Energy Manager

Newly introduced a Certificate Course in Measurement and Verification for Central Chilled Water Plant Efficiency – 120 attended

Green Buildings Enhance Asset ValueGreen Buildings Enhance Asset Value

BCA- NUS PROJECT ON VALUATION OF GREEN COMMERCIAL PROPERTIES

A saving of 10% in operating expense will translate into

a 2% increase in capital value.

• 4 weekly advertorials on business case of greening existing buildings

• In Straits Times July 2012

Green Building Advertorials

Upfront Capital cost

10% - 20%

• Invest in efficient Chiller Plant

Energy / maintenance cost

80% - 90%

Once in 15 years Opportunity

Incentives & Financing Assistance

S$100milINCENTIVES FOR

RETROFITTING EXISTING BUILDINGS (SINCE 2009)

Building Retrofit Energy Efficiency Financing (BREEF) Scheme

Provide financing to undertake energy efficiency

retrofits

Enhanced GMIS-EB Qualifying Criteria

Green Mark Requirement (Ver 3) + Air-conditioning

System EfficiencyCo-funding Rate Cap Amount

Gold + 0.7 kW/RT 35% $1,500,000

Goldplus + 0.65 kW/RT 40% $2,250,000

Platinum + 0.6 kW/RT 50% $3,000,000

Up toS$3 Million

Enhanced Green Mark Incentive Scheme – Existing Buildings

Amended in July 2012

Co-fund includes supply & installation of energy efficient equipment and professional services

Phase 2 Phase 3 Phase 4Phase 1

Four-Phased Approach to Green our Existing Building Stock

Legislation – New Bdgs (April 08)

Minimum EE Standards for New Building and Existing Buildings undergoing major retrofitting(GFA of >2000m2)

Incentive Scheme

(April 09)

GMIS (Existing Buildings) scheme co-fund upgrading for energy improvement.

Energy Data Submission

Yearly submission on energy consumption to BCA.Building owners to submit energy related building information.

Legislation –Existing

Buildings

Minimum EE standards for Existing Buildings and meet GM Certified

New and retrofitted existing buildings – 3 yearly system efficiency audit

• Three-yearly energy audit on cooling system

• Annual submission of building info & energy consumption data

• Min. GM standard for existing buildings

• Phase 1– Any hotel, retail building or

office building– GFA > 15,000m2

– Installing/replacing chilled-water cooling system.

– Must meet minimum GM Standard for Existing Buildings

• Lifespan of chilled-water cooling system is between 15 – 20 years

Energy Consumptions in Buildings

Cooling system

Lift

Lighting

Equipment

Others

Cooling system accounts for as much

as 50% of the building’s total energy

consumption.

Min. GM Standard for Existing Buildings1

Planning

• Owner engages a PE(Mech).

• PE (Mech) looks into the overall building design and ensures that the building can achieve at least Green Mark 50 points.

• Owner to submit the Green Mark design score, retrofitted design, drawings, computations for approval before commencement of the energy improvement works.

Retrofitting

Completion

• Owner must complete the energy improvement works within three years from the date of approval of the design score by BCA.

• Submit the Green Mark as-built score (at least 50 points) (including commissioning of the cooling system).

Min. GM Standard for Existing Buildings1

1Min. GM Standard for Existing Buildings

Buildings involved

Existing buildings which have undergone retrofitting and are required to meet min. GM standard for existing buildings.

New buildings (except industrial and residential) with centralised chilled-water building cooling system which are required to comply with the enhanced Green Mark standards for new buildings implemented on 1 December 2010

2 3-Yearly System Efficiency Audit

Chiller Plant Load and Efficiency 2 3-Yearly System Efficiency Audit

BCA serve Notice to building owner to carry out energy audit

Building owner engage PE(Mech) or Energy Auditor to carry out energy audit and comply with requirements

Submit complying energy audit results to BCA by deadline stipulated in Notice

2 3-Yearly System Efficiency Audit

Purpose

Basis of the national energy benchmarks

Sharing of data with building owners for pro-active improvement to the energy performance of buildings

Measure effectiveness of energy efficiency initiatives

3 Annual Submission of Energy Data

Submit to BCA through Building Energy Submission System (BESS)

Useful links user submission manual technical guide demo-video

3 Annual Submission of Energy Data

1000

1000

1000

Similar BuildingActivity Type (Average)

EEI of Your Building

Similar BuildingActivity Type (Lowest)

Similar BuildingActivity Type (Highest)

3 Annual Submission of Energy Data

Green Buildings with Green Tenants

GM for Office Interior

GM for Restaurants

GM for Retail

GM for Supermarkets

GM for Non-Residential Building

New

New

We shape a safe, high quality, sustainable and friendly built environment.

Thank you