XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 1 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
XENTRY Update Service with
Retail Data Storage for
XENTRY Kit | Kit 2
Mercedes-Benz AG, GSP/ORE
Valid from 11/2019
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 2 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
Contents
1. Introduction ........................................................................................................................................................ 3
2. Configuring the XENTRY Kit | Kit 2 to download control unit software .................................................. 4
3. Downloading diagnosis updates ...................................................................................................................... 9
1. Configuring the Retail Data Storage ............................................................................................................... 9
2. Preparing the USB flash drive ........................................................................................................................ 11
3. Downloading the release update to a USB flash drive ................................................................................. 12
4. Installing the release update on the XENTRY Connect ................................................................................ 14
5. Installing the release update on the XENTRY Tab | Tab 2 / standard PC .................................................. 15
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 3 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
1. Introduction The Retail Data Storage unit allows you to obtain diagnosis updates and control unit software such as Regio DVDs and
Digital Operator's Manuals (DiBA) directly online. The data are transferred by the Retail Data Storage directly to the
XENTRY Kit | Kit 2 through your network connection.
1 Downloading control unit software
directly to the XENTRY Kit | Kit 2
1. Automatic transfer of
Regio DVDs and DiBA
from Daimler server to
your Retail Data
Storage
2. Demand-based
transfer of control unit
software (Regio DVD
and DiBA) to your
XENTRY Kit | Kit 2
3. Overwriting of control
unit software (Regio
DVD and DiBA)
2 Updating your XENTRY Kit | Kit 2 via
the Retail Data Storage
1. Automatic transfer of
software updates from
Daimler server to your
Retail Data Storage
2. Download of release
update to a PC as ZIP
file; followed by
transfer to a USB flash
drive
3. Installation of release
update on XENTRY
Connect and then on
the
XENTRY Tab | Tab 2
The prerequisite for this is pairing of the
XENTRY Kit | Kit 2 to the Retail Data Storage
(chapter 2).
The prerequisite for this is adjusting the
configuration of the Retail Data Storage
(chapter 3).
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 4 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
2. Configuring the XENTRY Kit | Kit 2
to download control unit software The Retail Data Storage available at your workshop enables you to retrieve control unit software such as Regio DVDs and
Digital Operator's Manuals (DiBA) online and to transfer these via your XENTRY Kit | Kit 2 system to the control unit in a
vehicle.
Please note the following requirements:
A Retail Data Storage must be available at your workshop.
Have your IT administrator provide you with the IP address of your Retail Data Storage.
To pair your XENTRY Kit | Kit 2 to the Retail Data Storage, proceed as follows.
1. Launch XENTRY Control via the shortcut on the desktop of your XENTRY Tab:
2. You will see the following home screen.
Please make sure that no connection between XENTRY Tab and XENTRY Connect is established.
Select the menu item "Configuration".
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 5 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
3. In the window that now opens, click on "Expert configuration".
4. Confirm the note that appears by clicking on "Continue".
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 6 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
5. Select the tab "XENTRY Tab / standard PC".
6. And in the next window, click on the tab "XENTRY Update Service".
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 7 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
8. Select "With Retail Data Storage" as the update mode and then enter the IP address of your Retail Data
Storage in the text field. You can obtain this IP address from your IT administrator.
Then select the button "Check connection".
9. If the check is successful, the connection is confirmed with a green check mark.
Now select the button "Apply configuration to XENTRY Tab/standard PC".
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 8 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
10. Confirm the information window that then appears by clicking on "Continue".
11. Finish the configuration process by clicking on "Finished".
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 9 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
3. Downloading diagnosis updates
1. Configuring the Retail Data Storage
Please note:
At the current time, only release updates for the XENTRY Diagnosis Kit 3 are downloaded by the Retail Data
Storage. The Retail Data Storage must be re-configured to download release updates for XENTRY Kit | Kit 2
systems.
To adjust the configuration of the Retail Data Storage, access your Retail Data Storage unit through your network either by
entering the IP address of the Retail Data Storage in the address bar of the browser on your XENTRY Kit | Kit 2 or
standard PC or by starting the XENTRY Update Service Control Center through your XENTRY Diagnosis Kit 3.
Navigate to the "Settings" menu item.
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 10 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
You may be asked to enter the password for your Retail Data Storage, enter it and then click on "Log in". The password
will have been assigned by your IT administrator, ask them for the password if necessary.
The "Configuration" window opens. Now check the box next to "XENTRY Kit | Kit 2 | XENTRY Connect" and then click on
"Save".
Please note: The downloading of release updates will start at the download times specified by your IT admin. These can
be changed in the "Download time configuration" menu item. The download can take up to several days depending on the
speed of your Internet connection.
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 11 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
2. Preparing the USB flash drive
You will need an empty USB flash drive to transfer the downloaded release update to your XENTRY Kit | Kit 2. It must have
a storage capacity of at least 64 GB.
Please plug the USB flash drive into the XENTRY Tab | Tab 2 / standard PC and wait a moment until it is detected by the
system.
Now open Windows Explorer, right-click on the data storage medium and select the "Format" item.
This opens the following window:
For the file system and size of the allocation units, the default values are recommended.
Please note:
The USB update function only supports NTFS as the file system. – The file systems of FAT, FAT32, and exFAT cannot be
used.
Assign a designation to the USB flash drive and check the selection box for quick formatting. Clicking the "Start" button
will format your USB data storage medium. You might have to confirm a dialog notifying you that all data will be deleted
during formatting of the data storage medium.
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 12 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
3. Downloading the release update to a USB flash drive
Navigate to the menu item "Overview of available releases". Here you can see which release updates are available. The
platform for which the respective release is available is also displayed. The "Status" column indicates whether the release
has already been fully downloaded to the Retail Data Storage; wait for the download to complete if necessary.
To download the desired release for your XENTRY Kit | Kit 2, click on ".ZIP" in the "Download release file" column in the
respective row.
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 13 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
An information window opens. Select "Save" here. The ".META" file does not have to be downloaded.
After successfully downloading the file, unpack the ZIP directory. Then copy all of the unpacked files to your USB flash
drive.
Please note: All files and directories must be located directly on the top level of the USB flash drive and may not be stored
in a sub-directory.
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 14 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
4. Installing the release update on the XENTRY Connect
Please note: The XENTRY Connect must be in standby mode to install the release update. You can shut down the XENTRY
Connect directly on the device via the menu (gearwheels button) or from the XENTRY Control session.
Connect the power supply unit to the XENTRY Connect and insert the USB data storage medium into a free USB port of
the XENTRY Connect.
Now start the update mode of the XENTRY Connect by simultaneously pressing the two "red cross" and "green tick"
buttons.
Once "Start update" appears on the display, confirm this with the green tick. The update procedure starts. This will be
indicated as follows on the XENTRY Connect display:
The USB update takes about 100 minutes. The XENTRY Connect indicates when the update is finished on the display.
You can complete the process by pressing the "gearwheels" button. Or, wait until the XENTRY Connect automatically
shuts down (approx. 10 minutes after the picture appears on the display).
XENTRY Update Service with Retail Data Storage for XENTRY Kit | Kit 2, version 11/19 (valid until revoked) page 15 of 15
Mercedes-Benz AG, Mercedesstr. 120, 70372 Stuttgart
5. Installing the release update on the XENTRY Tab | Tab 2 /
standard PC
Now insert the USB flash drive into a free USB port of your XENTRY Tab | Tab 2 / standard PC.
Run the "start.exe" file. The Update Wizard starts.
After the update procedure is completed successfully, you can exit the Wizard and your device is ready for use.
You have now updated your XENTRY Kit | Kit 2 / standard PC.