Work with TSC
Yong Guo
Introduction Non-inductive current for NSTX TSC model for EAST Simulation for EAST experiment Voltage second consumption for different
maximum plasma current Methods of saving voltage second Future work
Introduction
The Tokamak Simulation Code (TSC) is a numerical mode of an tokamak plasma and the associated control systems.
The code simulates the time evolution of a free boundary plasma by solving the MHD equations on a rectangular computational grid.
The MHD equations are coupled to the external circuits through the boundary conditions
The TSC model evolves the surface-averaged thermodynamic variables relative to magnetic coordinate surface.
Non-inductive current
TSC model for NSTX Reason:
limitation of voltage-second
Aim:
improve the fraction of non-inductive current
Non-inductive current:
NB driven current, bootstrap current
Introduction to simulation:
The simulation begins at 0.0sec, end at 5.0sec
The initial plasma current is 25KA Plasma reach flattop at 0.2sec The flattop last 4.8sec The transition from L-mode to H-mode is at
0.08sec NB is turned on at 0.12sec, and the
maximum amplitude is 6.15MW
.
* The non-inductive current is more than the total plasma current
.
Conclusion: compared to reference improve plasma confinement: increases central temperature and stored energy reduces the volt-second needed for plasma operation It improve bootstrap current and NB driven current It reach 100% non-inductive operation when anomalous transport coefficients equals
to 0.8. lower total plasma current: reduce the resistive volt-second consumption increase the total volt-second reduce bootstrap current and NB driven current increase the non-inductive current fraction and bootstrap current fraction Increase plasma density: increase bootstrap current and reduce NB driven current the non-inductive current fraction is close more resistive volt-second consumption and less inductive consumption the total volt-second consumption is close
TSC model for EAST PF coils: 14 PF coils
PF7 and PF9 connect together
PF8 and PF10 connect together
Vacuum vessel: divide into 4cm*4cm cross-section coils along vacuum vessel
Limiter point: inner limiter point (1.3634, 0.0) at the mid-plane
outer limiter point (2.3700, 0.0) at the mid-plane
Active coils: two active coils inside the vacuum vessel for VDE control
Computational region: 1.100m < R < 2.940m, 47 vertices
-1.400m < Z < 1.400m, 71 vertices
PF 7 and PF9 are in series, they share one power supplysame as PF 8 and PF 10
Simulation for EAST experiment Shot 7721 diagnostic data: surface voltage, PF current, plasma current, line average density EFIT: major radius, minor radius, elongation, Lack of diagnostic data central temperature, temperature profile, density profile, beta_p, internal inductance,
…… Plasma evolution: Ohmic discharge initial plasma current is 109.4KA, maximum current is 304.0KA ramp-up: 0.00sec - 0.95sec limiter configuration: 0.95sec - 2.03sec transition to divertor configuration: 2.03sec - 2.89sec divertor configuration: 2.89sec - 3.03sec transition to limiter configuration: 3.03sec - 4.46sec ramp-down: 4.46sec - 5.23sec
Ip (A) Surface voltage (V) Line average density (m^-2)
Group1 current (KA) Group2 current (KA) Group3 current (KA)
Group4 current (KA) Group5 current (KA) Group6 current (KA)
Major radius (m) Minor radius (m) Elongation
q(0)
Beta_torInternal inductance
Internal energy
Te(0) Te(0)/Te_av
Volt-second Vsec-abs
Summary: Central safety factor is larger than 1 in the evolution. And in the
EFIT calculation at chosen time slice, q0 is set as 1, and get a wrong li. vertical magnetic field, which mainly provided by group 6, is a function of beta_p+li/2. When I try to fit plasma position provided by EFIT, the simulation results of group 6 current disagree with Exp.
The line average density trajectory is not flat between 2sec and 4.5sec. It cause the internal energy and beta_t have the same change
The central electron temperature is about 900EV at flattop, and te(0)/Te_av, which signs electron temperature profile is about 2.75.
this shot start at -2.0328v*sec, end at 1.8513v*sec. Resistive consumption is large, about 77% at 4.5sec
Voltage second consumption for different Ip_max Choose five time slices of shot 7721 [0.0sec, 0.95sec, 2.03sec, 2.89sec, 3.03sec] Design new equilibrium use the plasma shape, internal inductance, poloidal beta at the chosen time
slice, design three sets of plasma equilibrium for 300KA, 500KA and 600KA, respectively
Follow the course of shot 7721 ramp up – limiter configuration – transition – divertor configuration Note flux linkage: -3.5 V-sec – 4.8 V-sec (due to the PF coil) same ramp up rate keep similar central temperature and temperature profile flatten the central density trajectory at flattop
group Maximum value 300KA 500KA 600KA
1 3920 KA -2.8373E3 KA -2.9925E3 KA -3.3413E3 KA
2 3920 KA -3.6261E3 KA -3.7562E3 KA -3.5469E3 KA
3 3920 KA -3.5953E3 KA -2.4462E3 KA -1.7664E3 KA
4 6944 KA 1.6247E2 KA 1.1638E3 KA 1.4409E3 KA
5 1680 KA -1.1976E3 KA -1.6689E3 KA -1.5441E3 KA
6 896 KA 1.1209E2 KA 1.8827E2 KA -1.0680E0 KA
(1) For 300KA, group 2 current is close to 95% of maximum value(2) For 500KA and 600KA, group 2 and group 5 current are close to 95% of their
maximum value
So, I choose 4.8V-sec as the maximum flux linkage for these simulation
The group coil current at 4.8V-sec for different I_max
300KA 500KA 600KA
First stage(ramp up)
Time 1.0s 2.0s 2.5s
Consumed V-sec 1.6 4.1 5.275
Second stage(limiter configuration)
Time 1.0s 1.0s 1.0s
Consumed V-sec 0.77 1.13 1.625
Third stage(transition)
Time 1.0s 1.0s 1.0s
Consumed V-sec 0.764 1.085 1.2132
Fourth stage(divertor configuratio
n)
Time 7.6s 2.0s 0.06s
Consumed V-sec 5.166 1.985 0.1750
(1) In the ramp up part, the demand of voltage-second raises quickly as Ip_max increases(2) In the other three parts, the demand of voltage-second raises slowly as Ip_max increases (3) The flattop time reduces as Ip_max increases(4) Ip_max>600KA, there is no enough voltage-second to form divertor configuration as shot 77
21 evolution
The volt-second consumption at the different stage for different I_max
Ramp up:
300KA (1.0sec) 500KA (2.0sec) 600KA (2.5sec)
Resistive 0.658 2.131 3.033
Inductive 0.328 0.656 0.705
External 0.616 1.313 1.537
Total 1.6 4.1 5.275
1. In ramp-up stage, plasma consumes 19.28% of total volt-second for 300KA, 49.4% for 500KA, and 63.55% for 600KA
2. With the increasing of Ip, the inductive component and external component increase slowly, and resistive component increases quickly
3. For 600KA case, resistive component take a large part of total flux needed, about 57.5%. For 300KA case, resistive component only take 39.25%
increase ramp up rate (taking 600KA as example):
Ramp up time 2.0s 1.5s 1.25s 1.0s
Voltage second
4.9623 4.2081 3.8865 3.5708
resistive 2.492 1.746 1.428 1.116
inductive 0.671 0.549 0.617 0.489
external 1.799 1.913 1.841 1.966
Note: (1) As ramp up time reduces, the total demand of voltage-second reduces. (2) The demand of resistive component reduces obviously. It takes 50.22% of total volt-second for ramp-up ti
me=2.0sec, and only 31.25% of total volt-second for ramp-up time=1.0sec.(3) The inductive component change small, due to it is used to establish magnetic configuration to hold plasm
a (4) It save 1.3915v-sec when ramp up time reduces from 2s to 1s. It could make divertor configuration about
0.4771sec longer
Methods of saving voltage second
Auxiliary heating and current driven :
Methods of saving voltage second
600KA , 2.5sec ramp-up ICRF for heating, and LH for heating and current driven ICRF is launched at 0.5sec for heating, and LH is launched at 0.6sec when the
plasma temperature is higher ICRF power profile is prescribed peaked profile For LH, the parallel index of refraction is limited by the plasma density
profile and temperature profile. The density profile and temperature profile are not optimized to make driven
current locate at somewhere. Here, I use the smallest n_para I find which can drive current.
Due to the heating of ICRF and LH, the plasma internal energy will increase. Due to the LH driven current and bootstrap current, the plasma current profile will change. It is difficult to design plasma at the chosen time slices for evolution calculation. I use former evolution result as the input for next evolution, make it convergence.
c
bkn par
1 2 3 4 5 6 7
ICRF 2MW 2MW 1MW 1MW 1MW 0.5MW 0.5MW
LH 2MW 0MW 2MW 1MW 0MW 1MW 0.5MW
N_para 5.2 ~ 6.0 6.7 ~ 7.8 7.8
q0 (t=2.5sec) 2.30 0.98 1.48 1.02 0.93 0.99 0.97
LH current 8.63e+4 ~ 7.63e+4 3.98e+4 ~ 2.66e+4 1.37e+4
BS current 1.57e+5 8.05e+4 1.12e+5 7.01e+4 5.97e+4 6.05e+4 5.19e+4
Resistive 0.6219 0.6904 0.7415 0.9849 1.117 1.285 1.564
Inductive 0.5901 0.8376 0.6155 0.7661 0.857 0.768 0.800
External 1.6070 1.615 1.622 1.632 1.603 1.631 1.634
Total 2.819 3.143 2.979 3.383 3.5774 3.684 3.988
Li(GA) 0.81 1.019 0.81 0.96 1.061 0.94 0.99
Beta_p 0.825 0.47 0.61 0.44 0.33 0.37 0.32
Auxiliary heating and current driven (taking 600KA as example):
Comparison case 1 and case 2
Same ICRF power and different LH power
LH driven current located at rou=0.4, make current profile off-axis
Off-axis current profile make li small, reduce the inductive volt-second consumption
Resistive volt-second consumption is close for two case
Off-axis current profile make q(0) large (2.3 for case 1, and 0.98 for case 2)
Some LH power deposit at rou=0.4 for case 1. It help to create more bootstrap current
(the same results for the comparison of case 3,4,5 and comparison of case 6,7)
T
Case 1
j (rou)
AUX heating
j (rou)
AUX heating
T
Case 2
Comparison case 1 and case 3
Same ICRF power and different LH power
Less beta_p and a little more resistive consumption for case 3
Smaller temperature for case 3 Less BS current created for case
3 LH driven current is smaller and
location is outer for case 3 Li is same for two case, and
inductive consumption is close
(same results for comparison of case 4 ,6)
j (rou) j (rou)
AUX heating AUX heating
T T
Case 1 Case 3
comparing case 2 and case 4
Same total power of LH and ICRF LH driven current located at rou=0.6 f
or case 4which turn on 1MW LH A little more q0 for case 4 Less Li and inductive volt-second con
sumption for case 4 Less temperature and more resistive
volt-second consumption for case 4 Less BS current for case 4 More non-inductive current for case 4
due to the contribution of LH current (3.98e4 A LH + 7.01e4A BS)
(same results for comparison of case 5 ,7)
j (rou)
AUX heating
T
j (rou)
AUX heating
Case 2 Case 4
Future work
In the this month Ptransp TSC work with Transp together
More practices with TSC such as: VDE study …
Thank you
Top Related