7/21/2019 Weld Dual Frequency_2014-07-31_10.56.36
1/3
Mentor Report
Weld Dual Frequency / Inspection
Instrument SettingsInput 1
TimeSlot1
Bridge Mode Receive Gain Drive Voltage
BRIDGE 100 22 dB 8
Frequency
SelectionFA
Channel Label Weld Inspection
Frequency 100.0 kHz
Drive Percentage 100 %
TimeSlot2
Bridge Mode Receive Gain Drive Voltage
BRIDGE ABS 16 dB 4
Frequency
SelectionFA
Channel Label CoatingMeasurement
Frequency 10.0 kHz
Drive Percentage 100 %
7/21/2019 Weld Dual Frequency_2014-07-31_10.56.36
2/3
Instrument SettingsInput 2
TimeSlot1
Bridge Mode Receive Gain Drive Voltage
BRIDGE 50 22 dB 8
Frequency
Selection
Channel Label
Frequency
Drive Percentage
TimeSlot2
Bridge Mode Receive Gain Drive Voltage
BRIDGE 50 22 dB 8
Frequency
Selection
Channel Label
Frequency
Drive Percentage
Panel SettingsAlarm 1 Delay 0.00 sec Alarm 1 Hold 0.5 sec
Alarm 2 Delay 1.00 sec Alarm 2 Hold 0.5 sec
Comparison View File \Data\comparisondata.pkt Comparison Enabled false
Shims 1 Shim Thickness nan mm
Drive RPM 1000 Sample Rate 1000 Hz
Persistence 2.0 sec Rotary Mode Off
Rotary Probe RPM 0 Rotary Sweeps 5
Scan Time (sec) 10.0 sec
7/21/2019 Weld Dual Frequency_2014-07-31_10.56.36
3/3
ChannelLabel
Frequency Gain X Gain Y Phase FilterSelection
LP Filter HP Filter
WeldInspection
100.0 kHz 48.6 dB 48.6 dB 82 deg Band Pass 100.0 Hz 0.0 Hz
CoatingMeasurement
10.0 kHz 55.9 dB 55.9 dB 70 deg Band Pass 100.0 Hz 0.0 Hz
Top Related