Dalian Taijia Technology Co.,Ltd
Ultrasonic level transmitter
UTG21-PYincludes several proprietary technologies, is safe and clean, with
high precision and long service life, stable and reliable, and convenient to
install and maintain, and is applicable to various fields of acid, alkali, salt,
anticorrosion, and high temperature. The meters all input and output lines
must be with such protection functions as lightning protection and short
circuit prevention.
Rrange: 015m
Blind area: 0.25m0.5m
Ranging accuracy : 0.3% Standard condition
Ranging resolution: 1mm
Pressure: Less than four atmospheric pressure
Display: With LCD to display liquid levels
Analog output: 4~20mA
Digital output: RS485 a greement,MODBUS protocol or customization
agreement (four-wire)
Power supply: DC24V or AC220V
Ambient temperature: -20~60
Protection grade: IP65
Installation: Nut or flange
UTG21-PS is separate type.the sensor PTFE material can be used for a
variety of corrosive occasions.
Rrange: 015m
Blind area: 0.25m0.5m
Ranging accuracy : 0.3% Standard condition
Ranging resolution: 1mm
Pressure: Less than four atmospheric pressure
Display: With LCD to display liquid levels
Analog output: 4~20mA
Digital output:RS485 a greement MODBUS protocol
or customization agreement (four-wire)
Power supply: DC24V or AC220V
Ambient temperature: -20~60
Protection grade: IP65
Installation: Wall type
7/25/2019 UTG+ultrasonic+level+transmitter
2/3
Dalian Taijia Technology Co.,Ltd
Wiring Diagram
Model selection guide
UTG21-P-
S:Separate type
Y:In line type
E: Two-wire
D: Four-wire DC24V
A: Four-wire AC220V
0:None on-off output
2:2-way on-off output
4:4-wa on-off output
T: RS485
X: None RS485
N: Common model
F: Corrosion prevention model
7/25/2019 UTG+ultrasonic+level+transmitter
3/3
Dalian Taijia Technology Co.,Ltd
Ultrasonic level transmitter
UTG21-Hs precision of liquid level can up to 0.3%, which is
enough to resist various interference waves. The transmitter is a
non-contact one and dose not directly contact liquid, so the fault rate
is low.
Rrange: 015m
Blind area: 0.2m0.5m
Accuracy: 0.3%
Direction angle: 4-6 (full angle)
Pressure: Less than four atmospheric pressure
Display: LCD display built-level height or distance
Analog Output: 4-20Ma
Supply voltage: two-wireDC24V 120mA
Ambient temperature: -20~60
Protection grade: IP67
Installation: Flange
Shell material: Aluminum Die Casting,proof-explosion shell
UTG21-BEis a non-contact one and dose not directly contact liquid,
so the fault rate is low. The meters all input and output lines must be
with such protection functions as lightning protection and short
circuit prevention.
Rrange: 020m
Blind area: 0.2m0.8m
Accuracy: 0.3%
Pressure: Less than four atmospheric pressure
Display: LCD display built-level height or distance
Digital output: RS485 Interface, MODBUS protocolor custom
Analog Output: 4-20Ma
Supply voltage: four-wireDC24V 120mA
Ambient temperature: -20~60
Protection grade: IP67
Proof-explosion grade: EX d[ia]iaBT4
Installation: Flange
Shell material: Aluminum Die Casting,proof-explosion shell