Download - UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

Transcript
Page 1: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

GRANT W KIGHTLINGERARCHITECTURAL ENGINEERING SENIOR THESIS

LIGHTING / ELECTRICAL OPTIONADVISORS: DR. HOUSER + PROF. DANNERTH

Final PresentationApril 15, 2009

UCI NATURAL SCIENCE UNIT I I

Page 2: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 3: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

PRESENTATION OUTL INE

NAME: UCI Natural Science Unit II

LOCATION: Irvine, California

OWNER: The University of California Irvine

SIZE: 146,075 ft²Five Stories

COST: $45 Million

FUNCTIONS: Science LaboratoriesFaculty OfficesGraduate Student Offices

PROJECT INTRODUCTION

Page 4: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

SUMMARY OF SPACES

N

1

43

2

1. NORTH FAÇADE AND PLAZA

2. LOBBY

3. CONFERENCE ROOM

4. OPEN OFFICE (3F)

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 5: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

DESIGN GOALS

SLEEK, MODERN AESTHETIC

BUILDING IDENTITY

VERTICAL + RADIAL MOTION

TRANSPARENCY

WARM EXTERIOR vs. COOL INTERIOR

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 6: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

PLAZA

CONFERENCE ROOM

WOODWALL

N

ELEVATOR

FOCAL POINTS

ATRIUM

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 7: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

DESIGN OBJECTIVES

1. Transparency to Plaza

2. Signature View

3. Highlight Center

4. Facial Rendering

5. Radial + Vertical Motion

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 8: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 9: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 10: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 11: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 12: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 13: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 1F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 14: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY 2F

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 15: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – LOBBY

HORIZONTAL ILLUMINANCE

Goal: 10.0 fcResult: 10.1fc (1F) OK

9.8fc (2F) OK

POWER DENSITY

ASHRAE 90.1: 1.30 W/ft²Result: 0.79 W/ft² OK

NFIRST FLOOR

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 16: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

CREDENZAWALL

TABLE

ARTWORK

PATIO

WHITEBOARD /PROJECTION SCREEN

FOCAL POINTS

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 17: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

DESIGN OBJECTIVES

1. Transparency to Patio2. Scene Flexibility3. Peripheral Emphasis4. Facial Rendering

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 18: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

CONTROL SCENES

1. Meeting / Classroom2. AV Presentation3. Social

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 19: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 20: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 21: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 22: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 23: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

TECHNICAL OBJECTIVE SUMMARY

PRESENTATION OUTL INE

L IGHTING – CONFERENCE ROOM

NMEETING / CLASSROOM

DESCRIPTION GOAL RESULT MET?

Meeting /

Classroom Mode

Table: 30 fc Avg. 33.7 fc YES

Credenza: 15 fc Avg. 25.0 fc YES

Whiteboard: 30 fc Avg. 35.6 fc YES

Faces: 15 fc Avg. 25.6 fc YES

A/V Presentation ModeProjection Screen: < 5 fc Max 2.6 fc YES

Table: 15-30 fc Avg. 16.3 fc YES

Social ModeFaces: 15 fc Avg. 16.1 fc YES

Credenza: 15 fc Avg. 28.3 fc YES

Power Density (ASHRAE 90.1) 1.3 W/SF (Space Method) 0.56 W/SF YES

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 24: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

ELECTRICAL – PV ARRAY ANALYSIS

N

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 25: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

ELECTRICAL – PV ARRAY ANALYSIS

N

Unoccupied Roof Area: 21,302 ft²Usable Roof Area (75%): 15,976 ft²PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 26: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

ELECTRICAL – PV ARRAY ANALYSIS

SELECTED PV PANELBP SOLAR - BP 3165

Rated Power: 165 WattsNominal Voltage: 24V

Module Efficiency: 13.1%Frame Size: 13.6 ft²

Usable Roof Area: 15,976 ft²Total Installable Units: 1,174 Panels

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 27: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

ELECTRICAL – PV ARRAY ANALYSIS

TOTAL SYSTEM COST (RS MEANS 2009)

$2,211,033

AVAILABLE INCENTIVES

Calif. Solar Initiative: $293,169Federal Tax Credit: $456,000

TOTAL Incentives: $749,169

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 28: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

ELECTRICAL – PV ARRAY ANALYSISRETSCREEN ENERGY ANALYSIS

Utility Cost: $0.09033 / kWhWeather Data: Long Beach, Ca

Annual Production: 270.5 MWhAnnual Utility Savings: $24,434

Payback Period: 19.4 YearsRecommended

CASHFLOW (USD)

YEARS

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 29: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

MECHANICAL – CURTAIN WALL ANALYSISDIRECT SOLAR PENETRATIONSummer Solstice – Worst Case

9 AM 11 AM

1 PM 3 PM

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 30: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

MECHANICAL – CURTAIN WALL ANALYSIS

EXISTING GLAZINGHeat Mirror 66

U-Value: 0.29SHGC: 0.37

Annual Heat Gain: 99,599 kBTU

PROPOSED GLAZINGPPG SolarBan 70XL

U-Value: 0.26SHGC: 0.27

Annual Heat Gain: 72,539 kBTU

27% ImprovementRecommended

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 31: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

DAYLIGHTING – OPEN OFFICE

N

WINDOWSPROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 32: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

DAYLIGHTING – OPEN OFFICE

N

ONE-ROW DIMMING

WINDOWS

WINDOWS

Illuminance DataClear Sky – Winter Solstice 12PM

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 33: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

DAYLIGHTING – OPEN OFFICE

DAYSIM ENERGY ANALYSIS

Desired Workplane Illuminance: 30 fc (without personal task)Lighting Power Density: 0.86 W/ft²

Non-Dimming Power Use: 2914.7 kWh Annually

Dimming System Power Use: 477.0 kWh Annually

$220 Annual Energy SavingsNot Recommended

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 34: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

PRESENTATION OUTL INE

CONCLUSIONS

LIGHTINGTechnical and Design Objectives Achieved

ELECTRICALPhotovoltaic Array:

Recommended – 19.4 Year Payback

MECHANICALCurtain Wall Glazing:

Recommended - 29% Improvement with SolarBan Glazing

DAYLIGHTINGOffice Dimming System:

$220 Annual Savings – Not Recommended

PROJECT INTRODUCTION

SUMMARY OF SPACES

DESIGN GOALS

LIGHTING – LOBBY

LIGHTING – CONFERENCE ROOM

PHOTOVOLTAIC ARRAY ANALYSIS

CURTAIN WALL ANALYSIS

OFFICE DAYLIGHTING STUDY

CONCLUSIONS

Page 35: UCI NATURAL SCIENCE UNIT II · outline. lighting – lobby 1f n. project introduction. summary of spaces. design goals. lighting – lobby. lighting – conference room. photovoltaic

ACKNOWLEDGEMENTS

The University of California IrvineClifford Stokes Jr., Robyn Stiffler

Design TeamCarrier-Johnson Architects – Gary Hipolite, Philip Pipal

Tangram Interiors – Tom Walsh

Penn State AE FacultyThesis Review Panel

Dr. Kevin HouserProf. Ted Dannerth

Prof. M. Kevin ParfittProf. Robert Holland

AE Colleagues