REFERENCE O-3001-1 version 1.0.0
Company / Organization UIC ERTMS/GSM-R Operators Group
Test specifications for GSM-R MI related requirements
Part 1: Cab Radio
ACCESS: Public Restricted Confidential
Document Data Sheet
Title of the document Test specifications for GSM-R MI related requirements; Part 1: Cab Radio
Reference, version number and
date
REFERENCE O-3001-1 version 1.0.0; Date: 20.07.2017
Number of pages 118
Prepared by Funkwerk Systems (Alexander Ende)
Checked by CEF Activity beneficiaries
Approved by ERTMS/GSM-R UIC ERIG Chairman (Robert Sarfati)
ISBN 978-2-7461-2592-6
Warning
No part of this publication may be copied, reproduced or distributed by any means whatsoever, including electronic, except for
private and individual use, without the express permission of the International Union of Railways (UIC). The same applies for
translation, adaptation or transformation, arrangement or reproduction by any method or procedure whatsoever. The sole
exceptions - noting the author's name and the source -are “analyses and brief quotations justified by the critical, argumentative,
educational, scientific or informative nature of the publication into which they are incorporated” (Articles L 122-4 and L122-5 of
the French Intellectual Property Code).
International Union of Railways (UIC) - Paris, 2017
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 version 1.0.0 3/117
Evolution Sheet
Revision Date Author Object of revision
x.0.1 2016-11 Funkwerk Systems Creation based on O-3001 v2.1.1
x.0.2 2016-11 Funkwerk Systems Changes after TIG review
x.0.3 2017-02 Funkwerk Systems Changes after NoBo review
x.0.4 2017-02 Funkwerk Systems Changes after Ad Hoc Group review
x.0.5 2017-03 Funkwerk Systems Changes after NoBo review
x.0.6 2017-03 Funkwerk Systems Changes after TIG review
1.0.0 2017-05 UIC Approval by UIC
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 version 1.0.0 4/117
Contents
Evolution Sheet ........................................................................................................................... 3
Contents ...................................................................................................................................... 4
1 Object ............................................................................................................................... 8
1.1 Purpose of the document .......................................................................................................................... 8
1.2 Abbreviations ........................................................................................................................................... 8
1.3 Reference Documents ............................................................................................................................ 11
2 Test Configuration ......................................................................................................... 12
2.1 Overview ................................................................................................................................................ 12
2.2 Equipment required ................................................................................................................................ 12
2.3 Network configuration ........................................................................................................................... 12
2.4 Cab Radio configuration ........................................................................................................................ 13
2.4.1 Software ........................................................................................................................................ 13
2.4.2 Hardware ....................................................................................................................................... 13
2.4.3 SIM cards ...................................................................................................................................... 13
3 Completion of the Functional tests ................................................................................ 14
3.1 General ................................................................................................................................................... 14
3.2 Structure of the tests ............................................................................................................................... 14
3.3 Completion of the tests .......................................................................................................................... 14
3.4 Cab Radio test configuration.................................................................................................................. 14
4 EIRENE Requirements for Cab Radio: Mandatory for Interoperability ....................... 16
4.1 Power on / Power off functions .............................................................................................................. 16
4.1.1 System boot - error-free device ..................................................................................................... 16
4.1.2 System boot – faulty device .......................................................................................................... 16
4.1.3 Loudspeaker volume at power-on ................................................................................................. 17
4.1.4 System boot – no GSM-(R) network coverage ............................................................................. 17
4.1.5 Power-off and back on with different network coverage .............................................................. 18
4.1.6 Saving numbers at power-off ........................................................................................................ 18
4.2 MMI functions ....................................................................................................................................... 19
4.2.1 MMI activation ............................................................................................................................. 19
4.2.2 MMI deactivation.......................................................................................................................... 20
4.2.3 MMI language selection ............................................................................................................... 22
4.3 Self-test functions .................................................................................................................................. 23
4.3.1 Manual self-test ............................................................................................................................. 23
4.3.2 Manual self-test – incoming call ................................................................................................... 23
4.4 Network related features ........................................................................................................................ 24
4.4.1 Manual network selection – idle mode ......................................................................................... 24
4.4.2 Manual network selection – during ongoing call .......................................................................... 25
4.4.3 Visualisation – network loss ......................................................................................................... 25
4.4.4 Visualisation – "no EIRENE network" ......................................................................................... 26
4.4.5 Numbering plan ............................................................................................................................ 26
4.4.6 Location Dependent Addressing ................................................................................................... 27
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 version 1.0.0 5/117
4.4.7 Bearer service ............................................................................................................................... 28
4.5 Operation in idle mode ........................................................................................................................... 28
4.5.1 Main components of the Cab Radio .............................................................................................. 28
4.5.2 Loudspeaker volume ..................................................................................................................... 29
4.5.3 Phone number entries .................................................................................................................... 29
4.6 Entry of train data .................................................................................................................................. 30
4.6.1 Registration of train data ............................................................................................................... 30
4.6.2 Correction of train data ................................................................................................................. 30
4.6.3 Re-registration after changing networks ....................................................................................... 31
4.6.4 Registration of functional address to other driver (non-leading driver) ........................................ 32
4.6.5 Registration / deregistration of stock number ............................................................................... 33
4.6.6 Deregistration of train number ...................................................................................................... 33
4.6.7 Deregistration of train number – not successful ............................................................................ 34
4.6.8 Forced deregistration .................................................................................................................... 34
4.6.9 Follow-me service control sequences ........................................................................................... 36
4.7 Text messaging ...................................................................................................................................... 37
4.7.1 Sending a text message using SMS teleservice ............................................................................. 37
4.7.2 Receiving a text message using SMS teleservice .......................................................................... 37
4.7.3 Receiving a text message – maximum length ............................................................................... 38
4.7.4 Receiving a text message – interaction with other calls ................................................................ 38
4.7.5 Cell Broadcast message ................................................................................................................ 39
4.8 Point-to-Point calls................................................................................................................................. 39
4.8.1 Incoming PTP call with eMLPP <4> and with no functional identity .......................................... 39
4.8.2 Incoming PTP call with eMLPP <4> and with train functional identity ....................................... 41
4.8.3 Incoming PTP call with eMLPP <4> and with engine/coach functional identity ......................... 41
4.8.4 Incoming call with eMLPP <0-3> ................................................................................................ 42
4.8.5 Leaving or terminating incoming calls ......................................................................................... 43
4.8.6 Outgoing PTP call – MSISDN or number of fixed network user (CoLP) .................................... 44
4.8.7 Outgoing PTP call – functional number ........................................................................................ 44
4.8.8 Outgoing PTP call – controller ..................................................................................................... 45
4.8.9 Outgoing PTP call – controller (fails) ........................................................................................... 46
4.8.10 Outgoing PTP call – train staff ..................................................................................................... 47
4.8.11 Outgoing PTP call – using the phone book ................................................................................... 47
4.8.12 Outgoing PTP call – priorities of functional identities.................................................................. 48
4.8.13 Terminating outgoing calls ........................................................................................................... 48
4.8.14 Incoming PTP call – during ongoing PTP call (CW / HOLD)...................................................... 50
4.8.15 Outgoing PTP call – during ongoing PTP call .............................................................................. 51
4.8.16 Higher priority PTP call – ongoing PTP call ................................................................................ 51
4.9 Group calls ............................................................................................................................................. 52
4.9.1 Incoming voice group call............................................................................................................. 52
4.9.2 Incoming voice group call – “other drivers in the area” ............................................................... 53
4.9.3 Group call participation depending on the activated GID ............................................................. 54
4.9.4 Outgoing voice group call ............................................................................................................. 55
4.9.5 Outgoing high priority voice group call – “other drivers in the area” ........................................... 56
4.9.6 Visualisation – "Unable to establish VGC" .................................................................................. 57
4.9.7 Leaving voice group call ............................................................................................................... 57
4.9.8 Terminating voice group call – “other drivers in the area” ........................................................... 57
4.9.9 Moving out of the group call area ................................................................................................. 58
4.10 Conference calls ..................................................................................................................................... 59
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 version 1.0.0 6/117
4.10.1 Multiparty call (MPTY) ................................................................................................................ 59
4.10.2 Multi-driver communication – leading driver ............................................................................... 59
4.10.3 Multi-driver communication – other driver .................................................................................. 60
4.10.4 Multi-driver communication – controller ...................................................................................... 61
4.11 Broadcast calls ....................................................................................................................................... 62
4.11.1 Incoming voice broadcast call ....................................................................................................... 62
4.11.2 Leaving a voice broadcast call ...................................................................................................... 62
4.11.3 Outgoing voice broadcast call ....................................................................................................... 63
4.11.4 Moving out of the broadcast call area ........................................................................................... 63
4.12 Call arbitration ....................................................................................................................................... 64
4.12.1 Call arbitration – ongoing railway emergency call ....................................................................... 64
4.12.2 Call arbitration – ongoing high priority point-to-point call .......................................................... 65
4.12.3 Call arbitration – ongoing high priority group call between drivers in the same area .................. 67
4.12.4 Call arbitration – ongoing operational group call to drivers in the same area ............................... 70
4.12.5 Call arbitration – ongoing call from a controller ........................................................................... 72
4.12.6 Call arbitration – ongoing “other drivers on same train” call ....................................................... 74
4.12.7 Call arbitration – ongoing chief conductor call (over radio link) .................................................. 76
4.12.8 Call arbitration – ongoing voice group call (eMLPP<3>) ............................................................ 78
4.12.9 Call arbitration – ongoing voice broadcast call (eMLPP<3>) ...................................................... 80
4.12.10 Call arbitration – ongoing point-to-point call (eMLPP<3>) ......................................................... 82
4.12.11 Call arbitration – ongoing voice group call (eMLPP<4>) ............................................................ 84
4.12.12 Call arbitration – ongoing voice broadcast call (eMLPP<4>) ...................................................... 86
4.12.13 Call arbitration – ongoing point-to-point call (eMLPP<4>) ......................................................... 88
4.12.14 Call arbitration – ongoing shunting emergency call ..................................................................... 90
4.12.15 Call arbitration – ongoing default group call in shunting mode .................................................... 91
4.12.16 Call arbitration – ongoing dedicated group call in shunting mode ............................................... 92
4.13 Railway emergency calls ....................................................................................................................... 94
4.13.1 Incoming railway emergency call ................................................................................................. 94
4.13.2 Outgoing railway emergency call ................................................................................................. 95
4.13.3 Deleted .......................................................................................................................................... 96
4.13.4 Railway emergency call – leaving group call area ........................................................................ 96
4.13.5 Railway emergency call – entering group call area ...................................................................... 96
4.13.6 Railway emergency call – re-dial after unsuccessful call ............................................................. 97
4.13.7 eREC backward compatibility ...................................................................................................... 98
4.14 Shunting mode ....................................................................................................................................... 99
4.14.1 Entering shunting mode – during ongoing call ............................................................................. 99
4.14.2 Entering shunting mode – idle mode ............................................................................................ 99
4.14.3 Shunting registration ................................................................................................................... 100
4.14.4 Shunting registration – failed registration ................................................................................... 101
4.14.5 Shunting group activation ........................................................................................................... 101
4.14.6 Shunting area change – joining ongoing shunting emergency call ............................................. 102
4.14.7 Shunting area change – during shunting group call .................................................................... 102
4.14.8 Exiting shunting mode ................................................................................................................ 102
4.14.9 Exiting shunting mode – during shunting group call .................................................................. 103
4.14.10 Storage of shunting data .............................................................................................................. 104
4.14.11 Group call in shunting mode ....................................................................................................... 104
4.14.12 Link Assurance Signal ................................................................................................................ 105
4.15 Call confirmation ................................................................................................................................. 106
4.15.1 Emergency call confirmation ...................................................................................................... 106
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 version 1.0.0 7/117
4.15.2 Emergency call confirmation – group call area change .............................................................. 107
4.15.3 Emergency call confirmation – network or power loss ............................................................... 108
5 EIRENE Requirements for Cab Radio: Mandatory for Interoperability – optional
components .................................................................................................................. 109
5.1 Public Address ..................................................................................................................................... 109
5.1.1 Public Address – incoming call .................................................................................................. 109
5.1.2 Call arbitration – ongoing public address call ............................................................................. 109
5.1.3 Call arbitration – ongoing public address call (over radio link) .................................................. 111
5.2 Intercom ............................................................................................................................................... 112
5.2.1 Intercom system - incoming call ................................................................................................. 112
5.2.2 Call arbitration – ongoing intercom call ..................................................................................... 113
5.2.3 Call arbitration – ongoing intercom call (over radio link) .......................................................... 114
5.3 Train-borne recorder ............................................................................................................................ 116
5.4 Bulk registration / deregistration .......................................................................................................... 116
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 8/117
1 Object
1.1 Purpose of the document
This document contains the test cases that are necessary for the functional validation of a Cab Radio
according to the EIRENE specifications FRS (see [2]) and SRS (see [3]). The test cases cover all the
requirements that have been identified as mandatory for interoperability (MI) according to the EIRENE
specification and which can be validated using functional tests. QoS and performance requirements for
voice and non-safety related data communications are not in the scope of this document.
1.2 Abbreviations
AC Access Code
AT Attention command set
BC Breakout Code
BTS Base Transceiver Station
CC Country Code
CN Coach Number
CR Cab Radio
CHPC Confirmation of High Priority Calls
CLIP Calling Line Identification Presentation
CoLP Connected Line Identification Presentation
CS Circuit Switched
CTS Centralized Train Signaling
DL Downlink
DSD Driver Safety Device
EDOR ETCS data only radio
EIRENE European Integrated Railway Radio Enhanced Network
eMLPP enhanced Multi-Level Precedence and Pre-emption
ETCS European Train Control System
EN Engine Number
eREC enhanced Railway Emergency Call
FFFIS Form Fit Functional Interface Specification
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 9/117
FI Functional Identity
FC Function Code
FN Functional Number
FRS Functional Requirements Specification
GBR Guaranteed Bitrate
GCA Group Call Area
GID Group call Identity
GPH General Purpose Handheld
GSM Global System for Mobile Communications
GSM-MT GSM Mobile Termination
GSM-R GSM-Railway, GSM train radio system
ISDN Integrated Services Digital Network
LAS Link Assurance Signal
LN Location Number
MCC Mobile Country Code
MLPP Multi-Level Precedence and Pre-emption
MMI Man – Machine Interface
MNC Mobile Network Code
MPTY Multiparty Supplementary Services
MS Mobile Station, GSM-R mobile phone with a valid SIM Card for the test
MT Mobile Termination/Terminated
NDC National Destination Code
OPH Operational Purpose Handheld
OPS Operational Purpose Handheld for Shunting
OTA Over The Air
OTDI Originator To Dispatcher Information
PA Public Address
PC Primary Controller
PDP Packet Data Protocol
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 10/117
PFN Presentation of Functional Number
PPP Point to Point Protocol
PS Packet Switched
PSC Power Supply Controller
PSK Phase Shift Keying
PTP Point-to-Point call
PTT Push to Talk
QoS Quality of Services
REC Railway Emergency Call
SC Secondary Controller
SDU Service Data Unit
SEC Shunting Emergency Call
SGC Shunting Group Call
SIM Subscriber Identification Module
SMS Short Message Service
SN Stock Number
SN Subscriber Number
SRS System Requirements Specification
TE Terminal Equipment
TN Train Number
UIC Union Internationale des Chemins de Fer
UL Uplink
USSD Unstructured Supplementary Service Data
UUIE User-to-User Information Element
UUS User-User Signalling
VBC Voice Broadcast Call
VBS Voice Broadcast Service
VGC Voice Group Call
VGCS Voice Group Call Service
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 11/117
1.3 Reference Documents
[1]* Cab Radio User’s Manual
[2] UIC, EIRENE Functional Requirements Specification
Doc.-N°: UIC CODE 950 v 0.0.2 | version: 8.0.0
[3] UIC, EIRENE System Requirement Specification
Doc.-N°: UIC CODE 951 v 0.0.2 | version: 16.0.0
[4]
COMMISSION REGULATION (EU) 2016/919 of 27 May 2016 on the technical
specification for interoperability relating to the ‘control-command and signalling’
subsystems of the rail system in the European Union
[5] UIC, FFFIS for GSM-R SIM Cards
Doc.-N°: P38 T 9001 | version: 5.0 (2015-12)
[6]
UIC, Loudspeaker and telephone systems in RIC coaches - Standard technical
characteristics
Doc.-N°: UIC CODE 568 | version: 3.0 (1996-01)
[7] Void
[8] UIC, Test specifications for GSM-R MI related requirements, Part 2: EDOR
Doc.-N°: UIC O-3001-2 | version: 1.0.0
[9] UIC, Test specifications for GSM-R MI related requirements, Part 3: SIM Cards
Doc.-N°: UIC O-3001-3 | version: 1.0.0
[10] UIC, Test specifications for GSM-R MI related requirements, Part 4: Network
Doc.-N°: UIC O-3001-4 | version: 1.0.0
* Document [1] refers to the User’s Manual of the tested type of Cab Radio. It is imperative to use the Cab
Radio User / Interface Manual corresponding to the tested version of the Cab Radio.
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 12/117
2 Test Configuration
2.1 Overview
Following components of the EIRENE GSM-R system are needed to execute the tests:
GSM-R Network(s)
Cab Radio (device under test)
General purpose radio (GPH) or operational purpose radio (OPH)
Shunting radio (OPS)
Dispatchers
SIM Cards
2.2 Equipment required
GSM-R network(s) operating in the R-GSM 900 band
GSM Abis-tracer or GSM A-tracer, in order to check the contents on the messages exchanged between
mobiles and network when required.
Cab Radio (device under test) which includes a GSM-R module with type approval
Fixed network controller (dispatcher)
Enough mobile stations (Cab Radio or handheld) to cover multiparty calls e.g. drivers multi-party call
(MPTY).
GSM-R SIM cards with all the services and features provisioned and configured for the appropriate
mobile user and function.
SIM card editor, in order to be able to modify the services and features provisioned and the
configuration on the SIM cards for the different test requirements
User’s Manual of the tested device
User’s Manual of the other mobiles involved testing
2.3 Network configuration
It is recommended that GSM-R network is fully compliant to the requirements listed in the set of
specifications applicable to GSM-R network, see [4]. However it is noted that some of the features are not
specifically required for Cab Radio testing.
It must be possible to adjust various functions within the network in order to carry out the Cab Radio tests.
The GSM-R network configuration shall at least support two location / group call areas.
The stationary work stations, especially for the primary controller, secondary controller, power supply
controller, traffic controller and high priority call acknowledgement centre belong to the test environment
and are provided by the test lab operator or the customer. The configuration of the used GSM-R network,
supplier and the software release of the network components such as e.g. network switching subsystem,
base station subsystem etc. must be documented in the test protocol. Optionally the network compliance
can be verified by [10].
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 13/117
2.4 Cab Radio configuration
2.4.1 Software
The software release of the Cab Radio must be declared in the test protocol.
2.4.2 Hardware
The hardware release of the Cab Radio must be declared in the test protocol.
2.4.3 SIM cards
The SIM cards need to be compliant to [5] and will be provided by the network operator or test lab
operator. Optionally the SIM card compliance can be verified by [9].
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 14/117
3 Completion of the Functional tests
3.1 General
The following chapters contain a detailed description of all functional tests provided for the Cab Radio.
3.2 Structure of the tests
The tests are structured as follows:
test title
purpose of the test
precondition for the test
reference to specific requirement(s)
completion of the test in individual steps
Where the term “User’s Manual” is used, the required action and/or any audible and/or visual indication
has to be referred to the User’s Manual of the tested Cab Radio.
3.3 Completion of the tests
The tests are carried out with at least one Cab Radio. If other subscribers are used they are identified by
MS-A, MS-B, MS-C (for mobile subscribers) or TE1, TE2 (for terminal equipment).
The entire series of tests has to be completed successfully once. The order of the tests during the test run
might vary.
If the result of a test case is PASSED then it does not need to be redone.
If the result of a test case is FAILED, the cause of the failure should be determined.
If the failure is not due to the CR-A (equipment under test) the test case needs to be retested after
correction of the fault. If the 1st test result is FAILED and the 2nd result is PASSED then the test case
needs to be retested again. The test case is passed only if the result was PASSED already at 1st test
execution or PASSED within 2nd and 3rd execution. Where the procedure section of a test case contains
“- none -” that means no action to be performed on the tested device, only on other devices (e.g. CR-B
or MS-A).
If the failure is due to the CR-A (equipment under test) this shall be recorded in the test report.
The priority and severity management of an issue that caused the test to fail is not subject of this document.
3.4 Cab Radio test configuration
The following requirements or settings apply to the Cab Radio test grouping:
Test system requirements:
EIRENE compliant GSM-R network (or in some test cases two networks) compliant to [4]
Subscriber for controller calls 1200, 1300, 1400 & 1500
Two primary controller (PC1, PC2) in different cell specific routing areas
Shunting radio with LAS function
Cab Radio
Handhelds
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 15/117
Public address and intercom system in accordance with [6]
(connected to the test unit if it supports it)
SIM card editor, in order to be able to modify the services and features provisioned and the
configuration on the SIM cards for the different test requirements.
External device for setting the test unit’s vehicle number (e.g. personal computer with appropriate
software installed)
The interface between the application and GSM-R modem can be recorded (is required, e.g. for testing
the correct format of the UUIE)
Test unit requirements
Equipped with a plug-in SIM card according to [5]
Group number 299 for railway emergency call, 599 for shunting emergency call (SEC) configured on
the SIM
Additional group numbers (e.g. 203) are enabled on the SIM
Voice broadcast groups (e.g. 200 or 998) are enabled on the SIM
Own phone number (MSISDN) entered on the SIM
Registered engine number entered on the SIM and on the network
Short numbers for the controllers have to be defined in the SIM (EFSDN) file, as defined in [5]
Unless otherwise specified CR is switched on and in Train Radio Mode (unless Shunting Radio Mode is
specified in precondition), MMI1 is activated, idle mode, registered as the lead vehicle
Further requirements
• SIM cards of CR & MS are activated
• SMS service centre number is stored on CR & MS SIM cards
• SIM of CR & MS does not contain any received SMS messages
• The following GIDs should be defined on SIM cards, and in network database:
- default train group*: CT(50)+GCA+GID (200)
- default maintenance group: CT(50)+GCA+GID (560)
- default shunting group*: CT(50)+GCA+GID (500)
- dedicated maintenance group: CT(50)+GCA+GID (561-568)
- dedicated shunting group*: CT(50)+GCA+GID (501-529)
- national broadcast group: CT(51)+GCA+GID (400-499)
- train broadcast group: CT(51)+GCA+GID (200)
* For interoperability
If required, the necessary deviations are listed in the individual test cases. The used test environment shall
be documented in the test report.
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 16/117
4 EIRENE Requirements for Cab Radio: Mandatory for
Interoperability
4.1 Power on / Power off functions
4.1.1 System boot - error-free device
Purpose: This test is to show the system start-up procedure and the default settings of an error-free
Cab Radio.
Precondition: Cab Radio test configuration. Cab radio is powered off and all units are error-free.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.1, 5.2.3.13
§ 4.4.1, 5.4.1, 5.4.2
Step Procedure Result / Effect
1 Power-on CR-A
- Indication of the start-up procedure visible on
the MMI
- Automatic self-test
- Network registration to the previously
registered network
- MMI default settings initialised
(e.g. brightness, audio profile, loudspeaker
volume,
handset volume)
- Default user language selected
- Acoustic signal: ready for operation
- Last used network selected
- Name of the network and indication of the
adequate signal strength is displayed on the
MMI
4.1.2 System boot – faulty device
Purpose: This test is to show that the automatic self-test during system start-up identifies a faulty
device and the according error message is displayed on the MMI.
Precondition: Cab Radio test configuration. An artificial defect shall be implanted into the CR-A
according to documentation (e.g. remove the Public Address and Intercom Unit).
Attention: To prepare this test, the CR-A system must be electrically powered off.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.1
§ 5.4.1
Step Procedure Result / Effect
1 Power-on CR-A
- Indication of the start-up procedure is
displayed on the MMI
- Automatic self-test
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 17/117
Step Procedure Result / Effect
2 - none -
(Initialisation finished)
- MMI default settings initialised
- Default user language selected
- Acoustic signal: ready for operation
- Name of the network displayed on the MMI.
- Error message - according to user’s manual – is
displayed on the MMI
4.1.3 Loudspeaker volume at power-on
Purpose: This test is to show that after a system start-up, the Cab Radio automatically selects the
default loudspeaker volume.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.17
§ 5.4.1i
Step Procedure Result / Effect
1a
Set the loudspeaker volume using MMI
menu or external device to „Quiet cab” or
equivalent
Loudspeaker volume set to the selected level 1b
Set the loudspeaker volume using MMI
menu or external device to „Normal cab” or
equivalent
1c
Set the loudspeaker volume using MMI
menu or external device to „Noisy cab” or
equivalent
2 Power-off CR-A CR-A powered off
3 Power-on CR-A Loudspeaker volume at the same level as before
4.1.4 System boot – no GSM-(R) network coverage
Purpose: This test is to show that after a system start-up an audible and visual indication is given if
connection to a GSM-(R) network is not possible.
Precondition: Cab Radio test configuration. The antenna cable should be removed from the GSM-MT
antenna connector or the network coverage of the BTS should be switched off (Radio
Signal < -110dBm).
Attention: To prepare this test, the Cab Radio must be electrically powered off.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.1
§ 5.4.3
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 18/117
Step Procedure Result / Effect
1 Power-on CR-A
- Indication of the start-up procedure is
displayed on the MMI
- Automatic self-test
2 - none -
(initialisation finished)
- MMI default settings initialised
- Default user language selected
- Audio-visual indication of no GSM-(R)
coverage
- Error message is displayed on the MMI
4.1.5 Power-off and back on with different network coverage
Purpose: This test is to show that after the Cab Radio is powered off it is no longer connected to the
GSM-(R) network and after it is powered on again the corresponding network availability is
displayed on the MMI.
Precondition: Cab Radio test configuration; Manual network selection is configured. CR-A has a
registered engine and train number.
References:
EIRENE FRS :
§ 5.2.3.1, 5.2.3.3
Step Procedure Result / Effect
1 Power-off CR-A CR-A powered off
2a - none –
(MS-A calls CR-A by MSISDN) No connection to CR-A
2b - none –
(MS-A calls CR-A by engine number)
3a Power-on CR-A (previous network
available)
- Audible indication is given
- Network name is displayed on the MMI
3b Power-on CR-A (only other network
available)
- Audio-visual indication is given for the
unavailability of the last used network
- Manual network selection needed for
connecting to other network
4.1.6 Saving numbers at power-off
Purpose: This test is to show that if the Cab Radio is powered off the last used numbers are saved.
Precondition: Cab Radio test configuration; Manual network selection is configured; Cab Radio registered
to CT4/CT3/CT2 functional numbers according to the test steps.
References:
EIRENE FRS :
§ 5.2.3.4
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 19/117
Step Procedure Result / Effect
1a Power-off CR-A
(CR-A registered only by CT4)
CR-A powered off 1b Power-off CR-A
(CR-A registered only by CT3)
1c Power-off CR-A
(CR-A registered by CT3/CT4 and CT2)
2 Power-on CR-A CR-A powered on and in default idle status
3a - none -
(Controller initiates a call to CR-A by CT4)
- Call established, communication possible
- CR-A sends correct PFN Tag5 to Controller 3b
- none -
(Controller initiates a call to CR-A by CT3)
3c - none -
(Controller initiates a call to CR-A by CT2)
4 Power-off CR-A CR-A powered off
5
- none -
(CR-A’s CT2 registration is removed from
subscription handling entity)
- none -
(CR-A powered off)
6 Power-on CR-A - CR-A powered on and in default idle status
- No Train Number is displayed on the MMI
7 CR-A initiates a call to Controller - Call established, communication possible
- CR-A sends PFN Tag5 with CT3/CT4 to
Controller
4.2 MMI functions
4.2.1 MMI activation
Purpose: This test is to show that the MMI can be activated using a soft switch-on function.
Precondition: Cab Radio test configuration. CR-A is powered on and its MMI is switched off (inactive).
MMI reset timer is set to t minutes.
References:
EIRENE FRS :
§ 5.2.3.6, 5.2.3.7
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 20/117
Step Procedure Result / Effect
1
(MMI was switched off with non-default
settings)
Switch-on the MMI
- Indication of the switch-on procedure
- Self-test of the MMI
2a - none -
(MMI was switched off less than t
minutes ago)
MMI powers on with the same configuration as
before
(e.g. previously set brightness / contrast / volume
levels)
2b - none -
(MMI was switched off more than t
minutes ago)
MMI powers on with the default configuration
(e.g. default brightness / contrast / volume levels)
4.2.2 MMI deactivation
Purpose: This test is to show that the MMI can be deactivated by a soft switch-off function during an
active call which is terminated or left by the Cab Radio. Deregistration of the train number
in shunting mode only possible if train number is already registered during shunting.
Precondition: Cab Radio test configuration; CR-A in train mode for steps 1-14 and later in shunting mode
for steps 5-14;
References:
EIRENE FRS :
§ 5.2.3.5, 5.2.3.9
Step Procedure Result / Effect
PTP / Voice Broadcast Call
1 CR-A registers a CT2 number CR-A has a CT2 registration
2a - none -
(Incoming broadcast call GID 20X) Call established, communication possible
2b CR-A initiates a PTP call to MS-A
3a During the active call, switch-off the MMI
(e.g. by using CR-A’s reversing switch or
MMI’s power switch, and if required by the
user’s manual, confirm deregistration of CT2
number )
- Active MMI becomes passive
- Broadcast call left
- Deregistration of the CT2 number
- Save data
3b
- Active MMI becomes passive
- PTP call terminated
- Deregistration of the CT2 number
- Save data
4
Switch-on the MMI
(e.g. by using CR-A’s reversing switch or
MMI’s power switch)
- MMI becomes active again
- CR-A in default idle status without CT2
registration
Voice Group Call
5 CR-A registers a CT2 / CT6 number CR-A has a CT2 / CT6 registration
6a - none -
(Incoming group call GID 200 / 50X) Call established, communication possible
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 21/117
Step Procedure Result / Effect
6b CR-A initiates a group call GID 200 / 50X
7a - none -
(uplink is taken by MS-A) MS-A can be heard on CR-A
7b (uplink is free)
CR-A press and hold PTT button CR-A can be heard on MS-A
8a During the active call, switch-off the MMI
(e.g. by using CR-A’s reversing switch or
MMI’s power switch, and if required by the
user’s manual, confirm deregistration of CT2
number)
- Active MMI becomes passive
- Group call left
- Deregistration of the CT2 number
- Save data
8b
- Active MMI becomes passive
- Group call terminated
- Deregistration of the CT2 number
Save data
9
Switch-on the MMI
(e.g. by using CR-A’s reversing switch or
MMI’s power switch)
- MMI becomes active again
- CR-A in default idle status without CT2
registration
Railway Emergency Call
10 CR-A registers a CT2 / CT6 number CR-A has a CT2 / CT6 registration
11a - none -
(Incoming emergency call GID 299 / 599) Call established, communication possible
11b CR-A initiates an emergency call GID 299 /
599
12a - none -
(uplink is taken by MS-A) MS-A can be heard on CR-A
12b (uplink is free)
CR-A press and hold PTT button CR-A can be heard on MS-A
13a
During the active call, switch-off the MMI
(e.g. b y using CR-A’s reversing switch or
MMI’s power switch, and if required by the
user’s manual, confirm deregistration of
CT2 number)
Preferred Implementation – call is left
immediately:
- Active MMI becomes passive
- Emergency call left
- Deregistration of the CT2 number
- Save data
- CHPC is sent with Tag5 containing CT2 / CT6
number and with CAUSE 0x10 (call was left
on user command)
Optional Implementation – call is not left:
- No change until the call is terminated by
another party
- After call termination active MMI becomes
passive
- Deregistration of the CT2 number
- Save data
- CHPC is sent with Tag5 containing CT2 / CT6
number and with CAUSE 0x00 (no error)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 22/117
Step Procedure Result / Effect
13b
During the active call, switch-off the
MMI
(e.g. b y using CR-A’s reversing switch or
MMI’s power switch, and if required by
the user’s manual, confirm deregistration
of CT2 number)
Preferred Implementation – call is terminated
immediately:
- Active MMI becomes passive
- Emergency call terminated
- Deregistration of the CT2 number
- Save data
- CHPC is sent with Tag5 containing CT2 / CT6
number and with CAUSE 0x00 (no error)
Optional Implementation – call is not terminated:
- No change until the call is terminated by the
driver (after releasing PTT), Controller or
network (timer)
- After call termination active MMI becomes
passive
- Deregistration of the CT2 number
- Save data
- CHPC is sent with Tag5 containing CT2 / CT6
number and with CAUSE 0x00 (no error)
14
Switch-on the MMI
(e.g. by using CR-A’s reversing switch or
MMI’s power switch)
- MMI becomes active again
- CR-A in default idle status without CT2
registration
4.2.3 MMI language selection
Purpose: This test is to show that the Cab Radio supports at least ten different languages on the
MMI for related prompts and information to be displayed. The user can select the
preferred language from a list of available languages.
Precondition: Cab Radio test configuration. CR-A is loaded with at least 10 different languages options.
References:
EIRENE FRS :
§ 5.2.3.12, 5.2.13, 5.2.3.14, 5.2.3.16
Step Procedure Result / Effect
1 CR-A activates MMI language selection
- List of available languages are displayed on
the MMI
- There are at least 10 different language
options
2 CR-A selects and activates a different
language than the currently used language
Information, prompts and menu items are changed
to the selected language on the MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 23/117
4.3 Self-test functions
4.3.1 Manual self-test
Purpose: This test is to show that the driver can manually initiate a Cab Radio self-test and the
results are displayed on the MMI.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
§ 5.2.3.44
Step Procedure Result / Effect
1a CR-A selects MMI menu for
manual self-test and starts the test
(All Cab Radio units are error-free) - Self-test is started
- Visual indication of the running self-test is
displayed on the MMI 1b
CR-A selects MMI menu for
manual self-test and starts the test
(Cab Radio has an artificially implanted
defect based on the self-test framework
declared by the manufacturer)
2 - none -
- Visual indication for the completed self-test is
displayed on the MMI
- Result of the self-test is displayed on the
MMI.
4.3.2 Manual self-test – incoming call
Purpose: This test is to show that an ongoing manually initiated self-test doesn’t prevent calls (e.g.
train emergency calls). The self-test is terminated by the incoming train emergency call.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
§ 5.2.3.44, 5.2.3.45
Step Procedure Result / Effect
1 CR-A selects MMI menu for
manual self-test and starts the test
- Self-test is started
- Visual indication of the running self-test is
displayed on the MMI
2 - none –
(MS-A initiates „train emergency call”)
- CR-A receives and joins the call automatically
- The ongoing self-test procedure is terminated
- Communication is possible
3 - none –
(MS-A terminates emergency call)
- Emergency call is terminated
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 24/117
4.4 Network related features
4.4.1 Manual network selection – idle mode
Purpose: This test is to show that the driver can select an authorised mobile radio network manually
from a prioritised list using MMI action and the Cab Radio can roam between EIRENE
networks.
Precondition: Cab Radio test configuration. Prioritised list of all authorised mobile radio networks
should be stored on the SIM of CR-A. At least two GSM-R networks should be available
and connected together so the de-registration command can be routed from one network to
the other.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.23, 5.2.3.23i, 5.2.3.25, 10.5.1, 11.3.4.1, 11.3.4.2, 11.3.4.3, 11.4.4
§ 5.6.1i, 10.5.1, 11.3.14, 11.3.15
Step Procedure Result / Effect
1 CR-A starts manual network selection
using a simple MMI action
Preferred Implementation: A prioritised list of all authorised mobile radio
networks
that are stored on the SIM is displayed in the
following order:
- Home EIRENE network
- Foreign EIRENE networks
- Non-EIRENE networks
Optional Implementation:
A prioritised list of authorised mobile radio
networks
that are stored on the SIM and are available at
the current location is displayed in the following
order:
- Home EIRENE network
- Foreign EIRENE networks
- Non-EIRENE networks
2 CR-A selects an authorised network and
starts changing the network Network selection procedure started
3 - none -
- Network selection is executed
- Registration of on-train functional numbers
based on the train number are executed
- After successful registration, de-registration
on the previous network are executed
- Progress of actions may be displayed on the
MMI
- New network name is displayed on the MMI
- New registration information is displayed on
the MMI
- CR-A returns to default idle status
4 CR-A initiate a call to the Primary
Controller using short code 1200 The call is initiated.
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 25/117
4.4.2 Manual network selection – during ongoing call
Purpose: This test is to show that the manual network selection function is not available when there
are ongoing calls involving the Cab Radio.
Preconditions: Cab Radio test configuration. CR-A is in an ongoing call with MS-A.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.24
§ 5.6.1i
Step Procedure Result / Effect
1 CR-A starts manual network change
using MMI menu
Network selection menu is not available
Network selection menu is available but
network change is not started
2 - none - - Network not changed
- CR-A continues the call
4.4.3 Visualisation – network loss
Purpose: This test is to show that loss of the GSM-R network is indicated audio-visually.
Purpose: Cab Radio test configuration
References:
EIRENE FRS :
EIRENE SRS :
§ 5.4.16
§ 4.4.1, 5.6.6
Step Procedure Result / Effect
1a Network coverage breaks off
(CR-A in train radio mode) - Visual indication for no signal strength is
displayed on the MMI
- Audio-visual indication for the network loss is
displayed on the MMI 1b Network coverage breaks off
(CR-A in shunting radio mode)
2a Restore network coverage
CR-A in idle train mode
2b CR-A in idle shunting mode
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 26/117
4.4.4 Visualisation – "no EIRENE network"
Purpose: This test is to show that the usage of networks with limited EIRENE functionality is clearly
indicated to the driver.
Purpose: Cab Radio test configuration
Network with limited EIRENE functions is selectable from the SIM
References:
EIRENE FRS :
§ 10.5.2
Step Procedure Result / Effect
1 CR-A changes the used network to
a network with limited EIRENE functions
- Network change indicated audio-visually
- Visual indication of the limited EIRENE
functionality - according to user’s manual –
is displayed on the MMI
4.4.5 Numbering plan
Purpose: This test is to show the correct handling of Numbering plan:
The correct handling of Group IDs
The correct handling of National EIRENE Numbers
The correct handling of international EIRENE Numbers
The correct handling of different Functional numbers and function Codes
Precondition: Cab Radio test configuration. MS-A registered to TN / EN / CN or a maintenance team
member or a national usage team member, according to the specific test steps.
References:
EIRENE FRS :
EIRENE SRS :
ITU-T :
UIC :
§ 9.2.1.1, 9.2.1.2, 9.2.2.2, 9.2.3.2, 9.2.4.1, 9.3.1, 9.3.2, 10.4.4, 11.2.1.1
§ 4.3.3., 4.3.4, 9.2.2, 9.2.4, 9.2.7, 9.2.9, 9.4.1, 9.5.3, 9.6.3, 9.6.4, 9.7.1, 9.9.2, 9A.2, 9A.3,
11.2.3
E.164
438-1, 438-3
Step Procedure Result / Effect
1 CR-A initiate a PTP call to MS-A
using MSISDN:
CT(8) + SN
- Call established successfully
- Communication possible
- CR-A terminates the initiated call
2 CR-A initiate a PTP call to MS-A
using Train Number:
CT(2) + TN + FC
3 CR-A initiate a PTP call to MS-A
using Engine Number:
CT(3) + EN + FC
4 CR-A initiate a PTP call to MS-A
using Coach Number:
CT(4) + CN + FC
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 27/117
Step Procedure Result / Effect
5 CR-A initiate a PTP call to MS-A
using Shunting team number:
CT(6) + LN +FC(5xxx)
6
(activate “high priority group call
between
drivers in the same area” for CR-A)
CR-A initiate a group call GID 200
7
(activate “operational group call to drivers
in the same area” for CR-A)
CR-A initiate a group call GID 555
8
(change CR-A to shunting and activate
“default shunting group”)
CR-A initiate a group call GID 500
9
(activate “dedicated shunting group” for
CR-A)
CR-A initiate a group call GID 50X
4.4.6 Location Dependent Addressing
Purpose: This test is to show that if the Cab Radio initiates a call to the primary controller then this
call is being routed to the controller corresponding to the current cell specific routing area
(except at border crossing).
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.4, 11.4.1, 11.4.4
§ 11.7.2
Step Procedure Result / Effect
1
(CR-A is in the location of PC1)
CR-A initiate a call to the Primary
Controller using short code 1200
The call is initiated to the selected controller (PC1)
2 - none –
(PC1 terminates the call)
The call is terminated with an audio-visual
indication
3
(CR-A moves into the location of PC2)
CR-A initiate a call to the Primary
Controller using short code 1200
The call is initiated to the selected controller (PC2)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 28/117
4.4.7 Bearer service
Purpose: This test is to show that the Cab Radio can receive data transmissions with different data
rates.
Precondition: Cab Radio test configuration; Data transfer call configured on MS-A (e.g. with
"AT+CBST=<speed>,<name>,<ce>") and data call initiated from MS-A (e.g. with
"ATD+MSISDN"). Network supports GSM bearer services:
- 24: Asynchronous 2.4 kbps Transparent (e.g. "AT+CBST=4,0,0")
- 25: Asynchronous 4.8 kbps Transparent (e.g. "AT+CBST=6,0,0")
- 26: Asynchronous 9.6 kbps Transparent (e.g. "AT+CBST=7,0,0")
References:
EIRENE SRS :
§ 4.3.2
Step Procedure Result / Effect
1a
- none -
(incoming Asynchronous Transparent
data call to CR-A with 2.4 kbps)
Call established, data transfer possible 1b
- none -
(incoming Asynchronous Transparent
data call to CR-A with 4.8 kbps)
1c
- none -
(incoming Asynchronous Transparent
data call to CR-A with 9.6 kbps)
4.5 Operation in idle mode
4.5.1 Main components of the Cab Radio
Purpose: This test is to show that the main components of the Cab Radio are all in place and
working.
Precondition: Cab Radio test configuration
References:
EIRENE FRS :
EIRENE SRS :
§ 5.4.1
§ 4.1.3.1, 5.2.2.1
Step Procedure Result / Effect
1
Check the following components of CR-
A:
- display
- control panel
- loudspeaker
- handset with PTT button
Components of CR-A are all in place and working.
2 CR-A initiate a call to MS-A - Call established, communication possible
- GSM-MT air interface is working correctly
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 29/117
4.5.2 Loudspeaker volume
Purpose: This test is to show that the volume of the Cab Radio loudspeaker can be adjusted
manually.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
§ 5.2.3.18
Step Procedure Result / Effect
1 - none –
(Incoming PTP call to CR-A) Call established, communication possible
2 Select volume settings for CR-A
loudspeaker Loudspeaker volume setting is activated
3a Increase loudspeaker volume Loudspeaker volume increased
3b Decrease loudspeaker volume Loudspeaker volume is decreased
4.5.3 Phone number entries
Purpose: This test is to show that the Cab Radio can access saved numbers and call lists.
Purpose: Cab Radio test configuration
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.39, 5.2.3.40
§ 5.5.16
Step Procedure Result / Effect
1 CR-A opens the MMI menu
for managing phone numbers
The following functions at least are available in this
menu. The order can differ and individual functions
can also be swapped out in separate menus (e.g.
VGCS), which are reached using additional soft keys
(see user’s manual):
- Phone book
- Phone number entry (manual dialling)
- Call list
- VGCS calls
- Driver conferences
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 30/117
4.6 Entry of train data
4.6.1 Registration of train data
Purpose: This test is to show that the leading driver can register a train number for the Cab Radio.
Precondition: Cab Radio test configuration ; CR-A not registered to any train number previously
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.26, 5.2.3.27, 5.2.3.34, 11.2.2.2, 11.3.2.1, 11.3.2.2
§ 4.3.3, 4.3.4, 9.2.4, 11.3.5
Step Procedure Result / Effect
1 CR-A selects train data entry menu Train data entry menu activated on the MMI
2 Enter train number and confirm - Only numbers can be entered
- Train number displayed on the MMI
3 Enter the function code for
leading driver and confirm Train function displayed on the MMI
4 Start registration
- Train number registration started using USSD
messages and protocols
- Registration progress is displayed on the MMI
- Indication of the successful registration is
sent back to CR-A
- Registration status is displayed on the MMI
(e.g. train number appears on the display)
5
- none –
(MS-A initiates a PTP call to CR-A
by Train Number and Function Code)
Call established, communication is possible
4.6.2 Correction of train data
Purpose: This test is to show that after a failed registration the train data can be corrected by the
user. The overriding of an automatic change (FRS 5.2.3.32) is not considered here as
automatic change is an optional feature.
Precondition: Cab Radio test configuration. CR-A is registered to a valid train number. MS-A has a
valid train number (different from CR-A) registration on the network.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.29, 5.2.3.30, 5.2.3.32
§ 11.3.12
Step Procedure Result / Effect
1 CR-A selects train data entry menu Train data entry menu activated on the MMI
2 Enter train number and confirm.
(same train number as MS-A) Train number displayed on the MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 31/117
Step Procedure Result / Effect
3
Enter the function code for
leading driver and confirm
(same function code as MS-A)
Train function displayed on the MMI
4 Start registration
- Registration progress is displayed on the MMI
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI.
- Registration status is displayed on the MMI
(e.g. “FN already in use”)
- Menu option provided for overriding the
currently registered train number
5 Return to idle mode and select
train data entry menu again - Train data entry menu activated on the MMI
6 Enter train number and confirm.
(same train number as MS-A) Train number displayed on the MMI
7 Enter the function code for other driver
(2nd driver) and confirm Train function displayed on the MMI
8 Start registration
- Registration progress is displayed on the MMI
- Registration status is displayed on the MMI
(e.g. train number updated on the display)
9 - none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code -
other driver)
Call established, communication possible
4.6.3 Re-registration after changing networks
Purpose: This test is to show that after changing to another network the same train number can be
used on the new network.
Precondition: Cab Radio test configuration. “Network 1” and “Network 2” are EIRENE GSM-R
networks or public networks with EIRENE facilities.
References:
EIRENE FRS :
EIRENE SRS :
§ 11.2.1.7, 11.2.1.8, 11.3.4.1, 11.3.4.2, 11.3.4.3
§ 11.3.14, 11.3.15
Step Procedure Result / Effect
1 CR-A registers Train Number on
“Network 1” Train Number registration is carried out
2
CR-A changes network to “Network 2”
(Train Number is not yet used on the new
network)
- Train Number is re-registered on the new
network automatically
- Train Number is deregistered on the old network
automatically
- New registration details are displayed on the
MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 32/117
4.6.4 Registration of functional address to other driver (non-leading driver)
Purpose: This test is to show the correct registration of the train number to the Cab Radio of the
other driver (non-leading).
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.33, 5.2.3.34
§ 4.3.3, 4.3.4, 9.2.4
Step Procedure Result / Effect
1 CR-A selects train data entry menu Train data entry menu activated on the display of the
MMI
2 Enter train number and confirm. Train number displayed on the MMI
3a Enter the function code for the
2nd driver and confirm
Train function displayed on the MMII
3b Enter the function code for the
3rd driver and confirm
3c Enter the function code for the
4th driver and confirm
3d Enter the function code for the
5th driver and confirm
4 Start registration
- Registration progress is displayed on the MMI
- Registration status is displayed on the MMI
(e.g. train number updated on the display)
5a
- none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code -
2nd driver)
Call established, communication is possible
5b
- none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code -
3rd driver)
5c
- none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code -
4th driver)
5d
- none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code -
5th driver)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 33/117
4.6.5 Registration / deregistration of stock number
Purpose: This test is to show that a Stock Number can be registered and deregistered.
Precondition: Cab Radio test configuration. If applicable, the interface to the external device is activated
or maintenance mode / menu is accessible. No Train Number or Stock Number is
registered to CR-A.
References:
EIRENE SRS :
§ 5.4.10, 11.3.5
Step Procedure Result / Effect
1
CR-A initiates registration of a Stock
Number
using maintenance functions
or by an external device
- Stock number registration started using USSD
messages and protocols
- Stock Number registered on the network
2
- none –
(MS-A initiates a call to CR-A Stock
Number)
Call established, communication possible
3
CR-A initiates deregistration of a Stock
Number
using maintenance functions
or by an external device
- Stock number deregistration started using USSD
messages and protocols
- Stock Number deregistered on the network
4
- none –
(MS-A initiates a call to CR-A’s new
Stock Number)
Call cannot be established
4.6.6 Deregistration of train number
Purpose: This test is to show the correct deregistration of the train number currently registered with
the Cab Radio.
Precondition: Cab Radio test configuration. Cab Radio has a train number registered on the network.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.34, 11.3.3.1, 11.3.3.2, 11.3.3.4, 11.3.3.5
§ 4.3.3, 4.3.4, 11.3.10, 11.3.12
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 34/117
Step Procedure Result / Effect
1
- none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code)
Call established, communication possible
2 - none –
(MS-A terminates the call) CR-A in default idle status
3 CR-A selects deregistration menu Deregistration menu activated on the display of the
MMI
4 CR-A starts deregistration
- De-registration progress is displayed on the
MMI
- De-registration successful, all FN associated
with
CR-A deregistered (e.g. data and fax ports)
- Registration status is displayed on the MMI
(e.g. train number is removed from the display)
5
- none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code)
PTP call cannot be established
4.6.7 Deregistration of train number – not successful
Purpose: This test is to show that the Cab Radio receives the result and cause after a failed
deregistration.
Precondition:
Cab Radio test configuration; Cab Radio has a train number registered on the network.
Deregistration must be barred on the network or the GSM service must be deactivated.
References:
EIRENE SRS :
§ 11.3.12
Step Procedure Result / Effect
1 CR-A selects deregistration menu Deregistration menu activated on the display of the
MMI
2 CR-A start deregistration.
(deregistration fails)
- Deregistration progress is displayed on the MMI
- Registration status is displayed on the MMI
(e.g. train number still present on the display)
4.6.8 Forced deregistration
Purpose: This test is to show that the Cab Radio can be forced to register to an already registered
(assigned) functional number. (e.g. train number)
Precondition: Cab Radio test configuration. MS-A has a train number registered on the network.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.3.29, 5.2.3.30, 5.2.3.31, 11.3.3.4, 11.3.3.5
§ 11.3.9i
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 35/117
Step Procedure Result / Effect
1 CR-A selects train data entry menu Train data entry menu activated on the display of the
MMI
2 Enter train number and confirm
(same train number as MS-A) Train number displayed on the MMI
3 Enter the function code for
leading driver and confirm
(same function code as MS-A)
Train function displayed on the MMI
4 Start registration
- Registration progress is displayed on the MMI
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Registration status is displayed on the MMI
(e.g. “FN already in use”)
- Menu option provided for overriding the
currently registered train number
5 Start forced deregistration
(optional user action on MS-A to
confirm the forced de-registration)
- Forced deregistration progress started in the
background:
Sends interrogation message
Receive MSISDN from the network
Send a forced de-registration message
Receive the answer
Send a registration message
Receive the answer
- Registration progress is displayed on the MMI
- Registration status is displayed on the MMI
(e.g. train number updated on the display)
6 - none –
(MS-A initiates a PTP call to CR-A by
Train Number and Function Code)
Call established, communication is possible
7 - none –
(MS-A terminates the call) CR-A in default idle status
8
- none –
(MS-A registers to the train number
associated with CR-A and performs a
forced deregistration)
- Audio-visual indication of the forced
deregistration is displayed on the MMI
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 36/117
4.6.9 Follow-me service control sequences
Purpose: This test is to show that the Cab Radio manages the Functional Number changes using the
Follow-me service control sequences. These functions can be used by MMI menu or by
external device.
Precondition: Cab Radio test configuration with at least one attached system. Cab Radio and ABIS trace
or protocol analyser.
References:
EIRENE FRS :
EIRENE SRS :
§ 11.3.3.4
§ 4.3.3, 5.4.7, 5.4.8, 5.4.9, 5.4.11, 11.3.2, 11.3.7, 11.3.14
Step Procedure Result / Effect
1 CR-A starts registration of FN
(lead driver and at least one other
system, e.g. Public Address)
- FN registration procedure successful
- Cab Radio trace contains "AT+CUSD"
messages (one for lead driver and one for each
other system):
* * 214 * SI * * * #
(where SI = International EIRENE Number)
or ABIS trace contains “DATIN” message with
“2A95..”
2 CR-A starts deregistration of FN
(lead driver and at least one other
system, e.g. Public Address)
- FN de-registration procedure successful
- Cab Radio trace contains "AT+CUSD"
messages (one for lead driver and one for each
other system):
# # 214 * SI * * * #
(where SI = International EIRENE Number)
or ABIS trace contains “DATIN” message with
“A391..”
3 CR-A starts interrogation of FN
- Interrogation procedure successful
- Cab Radio trace contains "AT+CUSD"
message:
* # 214 * SI * * * # (where SI = International EIRENE Number)
or ABIS trace contains “DATIN” message with
“AA91..”
4
CR-A changes network to another
GSM(-R) network with EIRENE
functionalities and
starts re-registration of FN
- FN re-registration procedure successful
- Cab Radio trace contains two "AT+CUSD"
messages:
first message: * * 214 * SI * * * #
second message: # # 214 * SI * * * #
(where SI = International EIRENE Number)
or ABIS trace contains two “DATIN” messages
with
“2A95..” followed by “A391..”
5 CR-A starts forced de-registration of
FN
- FN forced de-registration procedure successful
- Cab Radio trace contains "AT+CUSD"
message:
# # 214 * SI * 88 * MSISDN * #
(where SI = International EIRENE Number)
or ABIS trace contains “DATIN” message with
“A391..”
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 37/117
4.7 Text messaging
4.7.1 Sending a text message using SMS teleservice
Purpose: This test is to show that the Cab Radio can send text messages using teleservice SMS.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.2, 12.2.2
§ 4.3.1, 12.2.1, 12.2.2
Step Procedure Result / Effect
1
CR-A sends text message containing
160 characters to MS-A using MMI
menu
or by external device
- Text message sent from CR-A
- MS-A receives text message containing all 160
characters
4.7.2 Receiving a text message using SMS teleservice
Purpose: This test is to show that the Cab Radio can receive incoming text messages using
teleservice SMS.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.2, 5.2.2.62, 12.2.2
§ 4.3.1, 5.3.12, 12.2.1
Step Procedure Result / Effect
1 - none -
(MS-A sends a text message to CR-A
by MSISDN)
CR-A receives and stores text message
(message is stored automatically or by user input)
2 CR-A selects the SMS menu to read
the received text message Received text message displayed on the MMI
3 CR-A returns to default screen per MMI
action CR-A in default idle status
4 CR-A selects the SMS menu to read
the last received text message Stored text message displayed on the MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 38/117
4.7.3 Receiving a text message – maximum length
Purpose: This test is to show that the Cab Radio can receive text messages with a length of 160
characters using teleservice SMS.
Precondition: Cab Radio test configuration. Text message with 7bit encoding and with no extended
characters.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.2, 5.2.2.62, 12.2.2
§ 4.3.1, 5.3.12, 12.2.2
Step Procedure Result / Effect
1 - none -
(MS-A sends a text message to CR-A
containing 160 characters by MSISDN)
CR-A receives text message
2 CR-A selects the SMS menu to read
the received text message Received text message contains all 160 characters
3
- none -
(MS-A sends a concatenated text
message to CR-A containing 306
characters by MSISDN)
CR-A receives two text message
4 CR-A selects the SMS menu to read
the received text message Received text messages contain all 306 characters
4.7.4 Receiving a text message – interaction with other calls
Purpose: This test is to show that an incoming text message using teleservice SMS is correctly
received and indicated during a PTP call.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.2, 5.2.2.62, 12.2.2, 12.3.3
§ 4.3.1, 5.3.12, 12.2.1
Step Procedure Result / Effect
1 - none -
(Primary Controller initiates
a PTP call to CR-A)
PTP call established, communication is possible
2 - none -
(MS-A sends text message
to CR-A by MSISDN)
- CR-A receives text message
- Ongoing call with controller is maintained
3 Primary Controller terminates PTP call CR-A in default idle status
4 CR-A selects the SMS menu to read
the received text message Received text message displayed on the MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 39/117
Step Procedure Result / Effect
5 CR-A initiates „railway emergency call”
using “Emergency button” Railway emergency call is established
6 CR-A terminates the railway emergency
call Railway emergency call is terminated
7 CR-A selects the SMS menu to read
the received text message Received text message displayed on the MMI
8 - none -
(MS-A initiates “railway emergency
call”)
CR-A receives and joins call automatically
9 - none -
(MS-A terminates the railway
emergency call)
Railway emergency call is terminated
10 CR-A selects the SMS menu to read
the received text message Received text message displayed on the MMI
4.7.5 Cell Broadcast message
Purpose: This test is to show that certain cell broadcast message identifiers exist on the Cab Radio
and that "Cell Broadcast Messages" can be received.
Precondition: Cab Radio test configuration. Cab radio must be configured for reception of cell broadcast
messages of certain channels.
References:
EIRENE SRS :
§ 4.3.1
Step Procedure Result / Effect
1
- none -
(incoming Cell Broadcast message to CR-
A)
- CR-A receives Cell Broadcast message
- Cell Broadcast message can be read using MMI
menu or by external device
4.8 Point-to-Point calls
4.8.1 Incoming PTP call with eMLPP <4> and with no functional identity
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 40/117
Purpose: This test is to show that the Cab Radio can handle incoming calls with the lowest priority
and having no functional identity information for calling party. The priority of the call
makes it necessary to manually accept the call.
Precondition:
Cab Radio test configuration. CR-A and MS-A does not have a registered functional
identity. MSISDN of MS-A is not on the phonebook of CR-A. External network (e.g.
public GSM with appropriate SIM card) connected to the test network.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 4.2.3, 5.2.2i, 5.2.2ii, 5.2.2.43, 5.2.2.45, 5.2.2.46, 5.2.3.19, 9.5.1
§ 4.3.1, 4.3.3, 5.4.4, 5.5.19, 5.5.22, 9.7.4, 11.5.3
Step Procedure Result / Effect
1a
- none –
(MS-A initiate a PTP call from the
same network to CR-A by
MSISDN with eMLPP <4>)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Identification of the caller is displayed on the MMI 1b
- none –
(MS-A initiate a PTP call from a
foreign network to CR-A by
MSISDN and Access Code)
1c - none –
(Fixed terminal initiate a PTP call to
CR-A by MSISDN with eMLPP <4>)
2 CR-A accept the call using the MMI
- The call is accepted
- Visual indication is displayed on the MMI
- UUS1 information Tag5 is empty, MSISDN of the
connected party transmitted by CLIP
- MSISDN of MS-A is displayed on the MMI
- Caller can be heard on CR-A loudspeaker
3 CR-A pick up handset - Driver’s loudspeaker set to reduced volume
- CR-A handset activated, communication is possible
4 - none –
(MS-A terminates the call)
- Ongoing PTP call terminated.
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 41/117
4.8.2 Incoming PTP call with eMLPP <4> and with train functional identity
Purpose: This test is to show that the Cab Radio can handle incoming calls with the lowest priority
and including train functional identity of calling party. The priority of the call makes it
necessary to manually accept the call.
Precondition: Cab Radio test configuration. CR-A and MS-A has a registered train number.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 4.2.4, 5.2.2.44, 11.2.3.1, 11.2.3.5
§ 4.3.4, 5.5.2, 5.5.3, 11.5.1
Step Procedure Result / Effect
1 - none –
(MS-A initiate a PTP call to CR-A by
Train Number with eMLPP <4>)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Identification of the caller is displayed on the MMI
2 CR-A accept the call using MMI
or by picking-up handset
- The call is accepted
- Visual indication is displayed on the MMI
- UUS1 information Tag5 contains the Functional
Identity
- Functional Identity of the caller is displayed in a
readily understandable form on the MMI
- Caller can be heard on CR-A loudspeaker
3 - none –
(MS-A terminates the call)
- Ongoing PTP call terminated.
- CR-A in default idle status
4.8.3 Incoming PTP call with eMLPP <4> and with engine/coach functional identity
Purpose: This test is to show that the Cab Radio can handle incoming calls with the lowest
priority and including engine/coach functional identity of calling party. The priority of
the call makes it necessary to manually accept the call.
Precondition: Cab Radio test configuration. CR-A is functionally registered to engine/coach number.
References:
EIRENE SRS :
§ 5.4.4
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 42/117
Step Procedure Result / Effect
1a - none –
(MS-A initiate a PTP call to CR-A by
Engine Number with eMLPP <4>) - Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Identification of the caller is displayed on the MMI 1b
- none –
(MS-A initiate a PTP call to CR-A by
Coach Number with eMLPP <4>)
2 CR-A accept the call using MMI
or by picking-up handset
- The call is accepted
- Visual indication is displayed on the MMI
- Identification of the caller is displayed on the MMI
- Caller can be heard on CR-A loudspeaker
3 - none –
(MS-A terminates the call)
- Ongoing PTP call terminated.
- CR-A in default idle status
4.8.4 Incoming call with eMLPP <0-3>
Purpose: This test is to show that the Cab Radio can handle incoming calls with priority higher than
4. The call has to be automatically accepted if the call priority is of or exceeds eMLPP
<3>.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.3
§ 4.3.3, 5.5.2, 10.2.1
Step Procedure Result / Effect
1a - none –
(incoming call to CR-A with eMLPP
<3>)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- CR-A automatically accepts the call
- Identification of the caller is displayed on the MMI
1b - none –
(incoming call to CR-A with eMLPP
<2>)
1c - none –
(incoming call to CR-A with eMLPP
<1>)
1d - none –
(incoming call to CR-A with eMLPP
<0>)
2 - none –
(caller party terminates the call) - CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 43/117
4.8.5 Leaving or terminating incoming calls
Purpose: This test is to show that the Cab Radio can end or leave incoming calls in different ways.
Precondition: Cab Radio test configuration;
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2iii, 5.2.2.34, 5.2.2.60
§ 5.5.3, 5.5.23, 5.5.24, 5.5.26, 5A.3
Step Procedure Result / Effect
PTP call
1 CR-A receives a PTP call
Pick up handset Communication possible
2
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a-b) Call terminated
Multi-party call
3 CR-A receives a MPTY call
Pick up handset Communication possible
4
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a-b) CR-A leaves the call
(call terminated if there was only two subscribers
in it)
Group call
5 CR-A receives a VGC
Pick up handset Communication possible
6
The following actions are carried out:
a) Hang up handset.
b) Press "End" button
a) VGC placed on the loudspeaker
b) CR-A leaves the call
Drivers conference (other drivers on the same train)
7 CR-A receives a driver’s conference call
Pick up handset Communication possible
8
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a) Call placed on the loudspeaker
b) CR-A leaves the call
(call terminated if there was only two subscribers
in it)
Emergency call
9
CR-A receives an emergency call (GID
299)
Pick up handset
Communication possible
10
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a) Emergency call placed on the loudspeaker
b) No change, emergency call remains active
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 44/117
4.8.6 Outgoing PTP call – MSISDN or number of fixed network user (CoLP)
Purpose: This test is to show that the Cab Radio can initiate calls by dialling a MSISDN number
and the call is established with eMLPP <4>.
Precondition: Cab Radio test configuration. CR-A and MS-A does not have a registered functional
identity. Cab Radio and/or ABIS trace or protocol analyser to check message content.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2.42, 10.2.1, 10.2.2
§ 4.3.3, 5.3.11, 5.5.4, 5.5.14, 5.5.15, 5.5.17, 5.5.18, 10.2.1, 11.5.6
Step Procedure Result / Effect
1a CR-A initiates a call to MS-A by CT(8)
+ SN
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI 1b CR-A initiates a call to fixed network
user
(B-Party) by dialling its telephone
number
2 - none –
(MS-A/B-Party accepts the call)
- Call established to MS-A/B-Party with eMLPP <4>
- Visual indication is displayed on the MMI
- UUS1 information Tag5 is empty,
MSISDN of the connected party transmitted by
CoLP
- MSISDN of the connected party is
displayed on the MMI
- MS-A/B-Party can be heard on the loudspeaker
3 MS-A/B-Party terminates the call - Ongoing call terminated.
- CR-A in default idle status
4.8.7 Outgoing PTP call – functional number
Purpose: This test is to show that the Cab Radio can initiate calls by dialling a functional number
and the call established with eMLPP <4>
Precondition: Cab Radio test configuration. CR-A and MS-A has a registered functional identity. Cab
Radio and/or ABIS trace or protocol analyser to check message content.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2.42, 11.2.3.1
§ 4.3.3, 5.5.4, 5.5.14, 5.5.15, 11.5.1, 11.5.2, 11.5.4, 11.5.5
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 45/117
Step Procedure Result / Effect
1 CR-A initiates a call to MS-A by
dialling its Functional Number
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
2 - none -
(MS-A accepts the call)
- Call established to MS-A with eMLPP <4>
- Visual indication is displayed on the MMI
- UUS1 information Tag5 contains the Functional
Identity
- Functional Identity of the connected party is
displayed on the MMI
- MS-A can be heard on the loudspeaker
3 CR-A pick up handset - Loudspeaker set to reduced volume
- CR-A handset activated, communication possible
4 - none –
(MS-A terminates the call)
- Ongoing call terminated
- CR-A in default idle status
4.8.8 Outgoing PTP call – controller
Purpose: This test is to show that the Cab Radio can initiate calls to any types of controllers with a
minimum driver action (e.g. a single keystroke) and the call established with eMLPP <3>.
Precondition: Cab Radio test configuration. Call to Train Management Centre is only possible if an
ERTMS/ETCS system is connected to the Cab Radio.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 4.2.4, 5.2.2i, 5.2.2ii, 5.2.2iii, 5.2.2.1, 5.2.2.3, 5.2.2.3i; 5.2.2.4, 5.2.2.5, 5.2.2.6,
5.2.2.7, 5.4.3, 9.3.2, 10.2.1, 10.2.2, 11.4.1, 11.4.2, 11.4.5
§ 5.3.1, 5.3.2, 5.5.1, 5.5.4, 5.5.6, 9.4.1, 9.8.1, 9.8.2, 9.8.3, 9.8.4
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 46/117
Step Procedure Result / Effect
1a
CR-A initiates a call to
Primary Controller (no Functional Number registered to
CR-A)
- Call dialled out with the correct four digit short
code
(12xx – PC, 13xx – SC, 14xx – PSC)
- Audible indication for call proceeding is given on
the loudspeaker
- Visual indication for call proceeding is displayed
on the MMI
1b CR-A initiates a call to
Secondary Controller (Engine Number registered to CR-A)
1c CR-A initiates a call to
Power Supply Controller (Train Number registered to CR-A)
2 - none –
(Controller accepts the call)
- Call established to controller with eMLPP <3>
- Audible indication for call establishment is given
on the loudspeaker
- Visual indication for call establishment is displayed
on the MMI
- Identification of the connected party is
displayed on the MMI of CR-A
- Identification of the connected party is displayed
on the display of controller (TN / EN /
MSISDN)
- Controller can be heard on the loudspeaker
3 CR-A pick up handset
- Loudspeaker set to reduced volume
- Communication to controller is
activated on the handset of the CR-A
4 - none –
(Controller terminates the call)
- Ongoing call terminated.
- CR-A in default idle status
4.8.9 Outgoing PTP call – controller (fails)
Purpose: This test is to show that if the system cannot connect the call to a controller, an
appropriate audible and visual indication is provided to the driver.
Precondition: Cab Radio test configuration. (Routing of) Controller calls disabled.
References:
EIRENE FRS :
§ 5.2.2.1, 5.2.2.8
Step Procedure Result / Effect
1a CR-A initiates a call to Primary
Controller
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI 1b
CR-A initiates a call to Secondary
Controller
1c CR-A initiates a call to Power Supply
Controller
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 47/117
Step Procedure Result / Effect
2 - none –
(Call is not established)
- Call cannot be established
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- CR-A in default idle status
4.8.10 Outgoing PTP call – train staff
Purpose: This test is to show that the Cab Radio can initiate calls from a reconfigurable list of stored
numbers and perform abbreviated dialling to named user identities.
Precondition: Cab Radio test configuration; CR-A and Chief Conductor are registered to the same Train
Number.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2.38, 5.2.2.39, 5.2.2.40, 5.2.3.39, 5.2.3.40
§ 5.3.10, 5.5.4, 5.5.6, 5.5.9, 5.5.16
Step Procedure Result / Effect
1 CR-A activates function for calling train
staff using the MMI
- List of the trains ‘generic’ staff is displayed on
the MMI
(e.g. chief conductor; conductor; catering staff)
2 CR-A selects Chief Conductor from
the list and initiates a call to it
- Call initiated to CR-A’s Train Number with
FC10
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
3 - none –
(Chief Conductor accepts the call)
- Call established with eMLPP <3> using CT2 to
the registered train number and the
corresponding FC
- Visual indication is displayed on the MMI
- Identification of the connected party is
displayed on the MMI
4 - none –
(Chief Conductor terminates the call)
- Ongoing call terminated.
- CR-A in default idle status
4.8.11 Outgoing PTP call – using the phone book
Purpose: This test is to show that the Cab Radio can initiate calls from the phone book of the SIM
card.
Precondition: Cab Radio test configuration. Phone book has stored numbers with various different types
of calls and priorities.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.42, 5.2.3.39, 5.2.3.40
§ 5.5.4, 5.5.9, 5.5.11, 5.5.12, 5.5.13
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 48/117
Step Procedure Result / Effect
1 CR-A opens the phone book
using MMI menu Phone book opened, all entries are available.
2a CR-A selects the first phone book entry
and initiates a call to it
Voice calls are dialled and established with correct
eMLPP (priority <4> unless otherwise specified in the
dialled number)
or
if the subscriber is not available on the network the
reason for the connection failure is signalled.
2b CR-A initiates a PTP call
by phone book entry
2c CR-A initiates a VGCS call
by phone book entry
2d CR-A initiates a VBS call
by phone book entry
2e CR-A initiates a PTP call with eMLPP
<3> by phone book entry
4.8.12 Outgoing PTP call – priorities of functional identities
Purpose: This test is to show that the registered train number of the Cab Radio has priority over other
functional numbers. The functional number registration situations need to be created as
described in the test step. Then a call should be initiated to another subscriber a) via MMI
and b) via Intercom (when connected).
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.3i, 11.2.3.4
§ 4.3.3
Step Train number
(CT2)
Engine number
(CT3)
Coach number
(CT4)
Result
(FN in display)
1 Registered Not registered Registered CT2 (Train number)
2 Registered Registered Not registered CT2 (Train number)
3 Not registered Registered Not registered CT3 (Engine number)
4.8.13 Terminating outgoing calls
Purpose: This test is to show that the Cab Radio can end outgoing calls in different ways.
Precondition: Cab Radio test configuration;
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2iii, 5.2.2.34, 5.2.2.60, 13.2.4.1
§ 5.5.3, 5.5.23, 5.5.24, 5.5.25, 5A.2
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 49/117
Step Procedure Result / Effect
PTP call
1 CR-A initiates a PTP call
(handset in “off-hook” state) Call established, communication possible
2
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a-b) Call terminated
Multi-party call
3 CR-A initiates a Multi-party call
(handset in “off-hook” state) Call established, communication possible
4
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a-b) Call terminated
Broadcast call
5 CR-A initiates a VBS call
(handset in “off-hook” state) Call established, broadcast is possible
6
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a-b) Call terminated
Group call
7 CR-A initiates a VGCS call
(handset in “off-hook” state) Call established, communication possible
8
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a-b) Call terminated or left
Drivers conference (other drivers on the same train)
9 CR-A initiates a drivers conference call
(handset in “off-hook” state) Call established, communication possible
10
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a) Call placed on the loudspeaker
b) Call terminated
Emergency call
11
CR-A initiates an emergency call (GID
299)
(handset in “off-hook” state)
Call established
Communication is possible
12
The following actions are carried out:
a) Hang up handset
b) Press "End" button
a) Emergency call placed on the loudspeaker
b) Call terminated or left
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 50/117
4.8.14 Incoming PTP call – during ongoing PTP call (CW / HOLD)
Purpose: This test is to show that the Cab Radio manages call wait and call hold for incoming PTP
voice calls during an ongoing PTP voice call with the same or with lower priority.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.3, 5.2.3.42, 5.4.3
§ 4.3.3
Step Procedure Result / Effect
1a (MS-A initiate a PTP call to CR-A by
MSISDN with eMLPP <4>)
CR-A accept the call Call established, communication possible
1b (MS-A initiate a PTP call to CR-A by
MSISDN with eMLPP <3>)
CR-A accept the call
2 - none –
(MS-B initiate a PTP call (2nd call)
to CR-A by MSISDN with eMLPP <4>)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Details of the new incoming call are
displayed on the MMI
3 CR-A accept the call by MMI menu
- Call from MS-A (1st call) put on hold
- Displayed information on the MMI is updated
- Call from MS-B is active, communication is
possible
4 CR-A swap calls by MMI menu
- Call from MS-B (2nd call) put on hold
- Displayed information on the MMI is updated
- Call from MS-A (1st call) is active again,
communication possible
5 CR-A swap calls again by MMI menu
- Call from MS-A (1st call) put on hold
- Displayed information on the MMI is updated
- Call from MS-B (2nd call) is active again,
communication possible
6 CR-A terminates call using the MMI
menu
- Call from MS-B (2nd call) is terminated
- Displayed information on the MMI is updated
- Call from MS-A (1st call) is active again
7 CR-A terminates call by hanging-up
handset
- Call from MS-A (1st call) is terminated
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 51/117
4.8.15 Outgoing PTP call – during ongoing PTP call
Purpose: This test is to show that a PTP call can be placed on hold and a second PTP call can be
initiated.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.3, 5.2.3.42, 5.4.3
§ 4.3.3
Step Procedure Result / Effect
1 (MS-A initiate a PTP call to CR-A by
MSISDN with eMLPP <4>)
CR-A accept the call
Call established, communication possible
2 CR-A puts the ongoing call on hold and
initiate 2nd PTP call with eMLPP<4> to
MS-B
- Call from MS-A (1st call) put on hold
- Details of the new outgoing call are
displayed on the MMI
3 - none –
(MS-B accept the call)
- Visual indication is displayed on the MMI
- Identification of MS-B is displayed on the MMI
- Call to MS-B (2nd call) is active,
communication possible
4 CR-A terminates call using the MMI
menu
- Call to MS-B (2nd call) is terminated
- Displayed information on the MMI is updated
5
CR-A retrieve the call to MS-A
(previously
put on hold) automatically or by user
action
(implementation option)
Call from MS-A (1st call) is active again,
communication possible
6 CR-A terminates call by hanging-up
handset
- Call from MS-A (1st call) is terminated
- CR-A in default idle status
4.8.16 Higher priority PTP call – ongoing PTP call
Purpose: This test is to show that an ongoing PTP call should be either put on hold or cleared down
in case of a higher priority incoming or outgoing call
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.5, 5.2.4.6
§ 4.3.3
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 52/117
Step Procedure Result / Effect
1
(MS-A initiate a PTP call to CR-A by
MSISDN with eMLPP <4>)
CR-A accept the call
Call established, communication is possible
2 - none –
(incoming PTP call to CR-A with
eMLPP <3> from MS-B)
- Ongoing call terminated (“cleared down”)
- Incoming call from MS-B connected
3 CR-A terminates call - Call to MS-B is terminated
- CR-A in default idle status
4 (MS-A initiate a PTP call to CR-A by
MSISDN with eMLPP <4>)
CR-A accept the call
Call established, communication is possible
5 Call to Chief Conductor from CR-A
(over radio link) with eMLPP <3>
- Ongoing call is put on hold
- New call established
6 CR-A terminates call to Chief
Conductor using the MMI menu
- Call to Chief Conductor is terminated
- Displayed information on the MMI is updated
- Call from MS-A (1st call) is active again
7 CR-A terminates call by hanging-up
handset
- Call from MS-A (1st call) is terminated
- CR-A in default idle status
4.9 Group calls
4.9.1 Incoming voice group call
Purpose: This test is to show that the group call subscribed and activated on the Cab Radio is
received and managed correctly.
Precondition: Cab Radio test configuration. CR-A’s GID of the VGC 20X is activated.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2.47, 5.2.2.48, 5.2.2.49, 5.2.2.51, 5.2.2.52, 5.2.2.54, 5.2.2.61, 11.2.3.2
§ 4.3.1, 5.5.19
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 53/117
Step Procedure Result / Effect
1 CR-A handset is in “on-hook” state
(MS-A initiates VGC 20X with
eMLPP<3>)
- CR-A receives the call and accepts it
automatically
- Audible indication is given on the loudspeaker
- Visual indication including GID is displayed on
the MMI
- MS-A can be heard on CR-A’s loudspeaker
- Indication to use PTT to talk is displayed on the
MMI
2 CR-A pick up handset - Loudspeaker set to reduced volume
- Communication is activated on the handset
3 CR-A press PTT button
(uplink is busy)
- Audible indication is given on the loudspeaker
- Visual indication (e.g. “Uplink busy”) is
displayed on the MMI
4 CR-A press PTT button
(uplink is free)
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “You can talk”) is
displayed on the MMI
- CR-A can be heard on MS-A loudspeaker
5 CR-A release PTT Indication to use PTT to talk is given to MMI
6a CR-A leaves the call - Ongoing group call left
- CR-A in default idle status
6b - none –
(MS-A terminates the call)
- Call terminated
- CR-A in default idle status
4.9.2 Incoming voice group call – “other drivers in the area”
Purpose: This test is to show that a group call “other drivers in area” is received and managed by the
CR-A.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2iii, 5.2.2iv, 5.2.2.11, 5.2.2.47, 5.2.2.48, 5.2.2.49, 5.2.2.51, 5.2.2.52, 5.2.2.54,
5.2.2.61
§ 4.3.1, 5.5.19
Step Procedure Result / Effect
1
CR-A handset is in “off-hook” state
(MS-A initiates group call “other
drivers
in the area”)
- CR-A receives the call and accepts it
automatically
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- MS-A can be heard in CR-A’s handset
- Indication to use PTT to talk is displayed on the
MMI
2 CR-A press PTT button
(uplink is busy)
- Audible indication is given on the loudspeaker
- Visual indication (e.g. “Uplink busy”) is
displayed on the MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 54/117
Step Procedure Result / Effect
3 CR-A press PTT button
(uplink is free)
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “You can talk”) is
displayed on the MMI
- CR-A can be heard on MS-A loudspeaker
4 CR-A release PTT Indication to use PTT to talk is given to MMI
5 - none –
(MS-A press PTT and has the uplink) - MS-A can be heard on CR-A handset
6 CR-A hangs-up handset
(MS-A still has the uplink)
- Loudspeaker set to increased volume
- Ongoing call transferred to the loudspeaker
- MS-A can be heard on CR-A loudspeaker
7 MS-A terminates the call
- Group call “other drivers in the area” is
terminated
- CR-A in default idle status
4.9.3 Group call participation depending on the activated GID
Purpose: This test is to show that GIDs can be activated and deactivated on the Cab Radio and only
the activated GIDs’ group calls can be received.
Precondition: Cab Radio test configuration. GID VGC 20X is deactivated for CR-A.
References:
EIRENE FRS :
§ 10.4.1, 10.4.2, 10.4.3
Step Procedure Result / Effect
1 - none -
(MS-B initiate VGC 20X) Call is not received by CR-A
2
GID VGC 20X activation for CR-A
(by MMI menu / external device / SIM
OTA)
- Call is received by CR-A
- Communication is possible
3 - none -
(MS-B terminates the call) CR-A in idle mode
4
GID VGC 20X deactivation for CR-A
(by MMI menu / external device / SIM
OTA)
Display the GID status in accordance with user’s manual
5 - none -
(MS-B initiate VGC 20X) Call is not received by CR-A
6
GID VGC 299 deactivation for CR-A
(by MMI menu / external device / SIM
OTA)
No change (not possible to deactivate GID 299)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 55/117
4.9.4 Outgoing voice group call
Purpose: This test is to show that a voice group call can be initiated by the Cab Radio.
Precondition: Cab Radio test configuration. Additional VGC GIDs (e.g. 203) are activated on CR-A and
MS-A.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.3.39, 11.2.3.2
§ 5.5.4, 5.5.14, 5.5.15
Step Procedure Result / Effect
1
CR-A initiates a voice group call by
entering phone number or
using dedicated menu selection
(e.g. VGC 203, not VGC 200 or VGC
299)
- MS-A receives the call
- VGC established
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Indication to use PTT to talk is displayed on the
MMI
- Incoming audio is connected to the loudspeaker
until the driver picks up the handset
2 CR-A pick up handset and press PTT
- Loudspeaker set to reduced volume
- Communication is activated on the handset
- CR-A has a dedicated uplink until the PTT
button is released or the network timer expires
- CR-A can be heard on MS-A loudspeaker
3 CR-A release PTT Indication to use PTT to talk is displayed on the
MMI
4 CR-A press PTT button
(uplink is busy)
- Audible indication is given on the loudspeaker
- Visual indication (e.g. “Uplink busy”) is
displayed on the MMI
5 CR-A press PTT button
(uplink is free)
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “You can talk”) is
displayed on the MMI
- CR-A can be heard on MS-A loudspeaker
6 CR-A release PTT Indication to use PTT to talk is displayed on the
MMI
7 CR-A terminates group call - Call terminated
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 56/117
4.9.5 Outgoing high priority voice group call – “other drivers in the area”
Purpose: This test is to show that the group call “High priority group call between drivers in the
same area” is initiated and managed by the Cab Radio. The call established with eMLPP
<2> as it is read from the SIM Card.
Precondition: Cab Radio test configuration. MS-A and CR-A are in the same group call area.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2iv, 5.2.2.9, 5.2.2.11, 5.2.2.12, 5.2.2.13, 5.2.2.14, 5.2.2.15, 5.2.2.48, 5.2.2.54,
5.2.2.60, 5.2.4.9, 10.2.1, 10.2.2
§ 4.3.1, 5.3.3, 5.3.4, 5.5.6, 10.2.1
Step Procedure Effects
1
CR-A initiates group call “High priority
group call between drivers in the same
area” using
dedicated MMI menu selection
- MS-A receives the call
- VGC established with eMLPP <2>
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Indication to use PTT to talk is displayed on the
MMI
- Incoming audio is connected to the loudspeaker
until the driver picks up the handset
2 - none -
On the Controller’s display:
GID, GCA, call type and Functional umber of CR-A
(displayed information are based on the transmitted
UUS1 OTDI from CR-A during VGC establishment)
3 CR-A pick up handset and press PTT
- Loudspeaker set to reduced volume
- Communication is activated on the handset
- CR-A has a dedicated uplink until the PTT
button is released or the network timer expires
- CR-A can be heard on MS-A loudspeaker
4 CR-A release PTT Indication to use PTT to talk is given to MMI
5 CR-A press PTT button
(uplink is busy)
- Audible indication is given on the loudspeaker
- Visual indication (e.g. “Uplink busy”) is
displayed on the MMI
6 CR-A press PTT button
(uplink is free)
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “You can talk”) is
displayed on the MMI
- CR-A can be heard on MS-A loudspeaker
7 CR-A release PTT Indication to use PTT to talk is given to MMI
8 CR-A terminates group call - Call terminated
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 57/117
4.9.6 Visualisation – "Unable to establish VGC"
Purpose: This test is to show that the failure of a group call establishment is indicated audio-
visually.
Precondition: Cab Radio test configuration. VGC 20X barred in the network
References:
EIRENE FRS :
§ 5.2.2.17
Step Procedure Result / Effect
1 CR-A initiates a VGC 20X.
(call establishment barred in the network)
- CR-A displays the outgoing VGC 20X on the
MMI
- Failure of the call establishment indicated audio-
visually
- CR-A in idle mode
4.9.7 Leaving voice group call
Purpose: This test is to show that the Cab Radio can leave an ongoing voice group call without
terminating it.
Precondition: Cab Radio test configuration
References:
EIRENE FRS :
§ 5.2.2.61
Step Procedure Result / Effect
1 - none -
(MS-B initiates VGC 20X) CR-A receives group call and joins automatically
2 CR-A leaves the ongoing VGC
- VGC is left without being terminated
- CR-A in idle mode
- VGC 20X continues to exist on MS-B
3 - none -
(MS-B terminates VGC 20X)
- VGC 20X terminated
- CR-A still in idle mode
4.9.8 Terminating voice group call – “other drivers in the area”
Purpose: This test is to show that the group call initiated by the Cab Radio can be left when the
uplink is occupied. The group call stays connected between the other participants and re-
entry for the Cab Radio (initiator) is possible.
Precondition: Cab Radio test configuration. MS-A and CR-A are in the same group call area.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 5.2.2.15, 5.2.2.61
§ 5.5.24
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 58/117
Step Procedure Result / Effect
1 CR-A initiates group call
“other drivers in the area” MS-A receives group call
2 - none -
(MS-A takes the uplink by pressing
PTT)
MS-A can be heard on CR-A
3 CR-A tries to terminate group call Group call “other drivers in area” cannot be
terminated (uplink occupied by MS-A)
4
CR-A leaves group call
automatically after the termination
attempt
or manually by another MMI action
- Group call continues without CR-A
- CR-A in default idle status
5 CR-A initiates group call
“other drivers in the area”
- CR-A rejoins ongoing group call “other drivers
in area”
- Audible indication is given on the loudspeaker
- Visual indication with group identity is
displayed
6 (MS-A release PTT - uplink free)
CR-A press PTT button
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “Talk”) is displayed on
the MMI
- CR-A can be heard on MS-A loudspeaker
7 CR-A terminates group call - Group call “other drivers in area” is terminated
- CR-A in default idle status
4.9.9 Moving out of the group call area
Purpose: This test is to show that when the Cab Radio is in an ongoing group call and it leaves the
group call area the group call is also left.
Precondition: Cab Radio test configuration. CR-A first in train mode and later in shunting mode.
References:
EIRENE FRS :
§ 4.2.3, 5.2.2.16, 5.2.2.55
Step Procedure Result / Effect
1a CR-A initiates group call GID 200 /
GID 500
- Group call established
- MS-A receives and joins group call
1b
- none –
(MS-A initiates group call GID 200 /
GID 500)
- Group call established
- CR-A receives group call and joins call
automatically
2
- none –
(change the attenuation at the
handover machine to initiate cell change
and group call area change for CR-A)
- CR-A’s group call area changed
- CR-A leaves ongoing group call
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Group call continues at MS-A
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 59/117
4.10 Conference calls
4.10.1 Multiparty call (MPTY)
Purpose: This test is to show that a general multiparty call can be established and is handled
correctly by the Cab Radio.
Precondition: Cab Radio test configuration. CR-A, MS-A and MS-B has different registered train
numbers.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1
§ 4.3.3
Step Procedure Result / Effect
1 CR-A initiates a PTP call to MS-A PTP call to MS-A established
2 CR-A creates a multiparty call
with MS-A and MS-B
- CR-A initiate a PTP call to MS-B
- Multiparty call created between CR-A, MS-A
and MS-B
- Visual indication (e.g. “Multiparty call” ) is
displayed
on the MMI
- Communication is possible for every participant
3 - none –
(MS-A leaves the call)
- CR-A is notified of MS-A leaving the call
(optional)
- Call continues.
4 CR-A terminates the call - Ongoing multiparty call terminated.
- CR-A in default idle status
4.10.2 Multi-driver communication – leading driver
Purpose: This test is to show the communication with other drivers on the same train as a leading
driver.
Precondition: Cab Radio test configuration. CR-A, CR-B/C or MS-A/B are different drivers of the same
train.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1, 4.2.4, 5.2.2.26, 5.2.2.28, 5.2.2.29, 5.2.2.30, 5.2.2.31, 5.2.2.32, 5.2.2.33, 5.2.3.42
§ 4.3.3, 4.3.4, 5.3.8, 5.3.9, 5.5.6, 5.5.7
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 60/117
Step Procedure Result / Effect
1
CR-A creates a "Multi-driver call"
connecting 2nd driver (MS-A), 3rd
driver (MS-B) and 4th driver (CR-B)
by simplified automation or
guidance using the MMI
- When creating the "Multi-driver call" the
following steps were made by CR-A:
CR-A initiates PTP call to MS-A
CR-A places PTP call on hold
CR-A initiates next PTP call to MS-B
CR-A requests multiparty call
CR-A initiates next PTP call to CR-B
CR-A requests multiparty call
- Multiparty call established
- Visual indication (e.g. “multi-drivers” ) is
displayed on the MMI
- Communication is possible for every participant
2
- none –
(MS-A put the ongoing multiparty call
on hold)
- Notification is given for leading driver (CR-A)
for MS-A putting the call on hold
- Call is still active between the other participants
3a
- none –
(MS-A disconnects from
ongoing multiparty call) - Notification is given for leading driver (CR-A)
about disconnection of MS-A
- Call is still active between the other participants 3b
CR-A removes MS-A from
ongoing multiparty call
4 CR-A terminates multiparty call - Multiparty call terminated
- CR-A in default idle status
4.10.3 Multi-driver communication – other driver
Purpose: This test is to show the communication with other drivers on the same train as a non-
leading driver.
Precondition: Cab Radio test configuration. CR-A and CR-B/C or MS-A/B are different drivers of the
same train.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2iii, 5.2.2.28, 5.2.2.30, 5.2.2.34, 5.2.2.35
§ 5.5.19
Step Procedure Result / Effect
1
- none –
(CR-B as leading driver initiates a
“multi-drivers” call and connects CR-
A/C to it)
- Multiparty call established between CR-B and
CR-A and -C
- Visual indication (e.g. “multi-drivers” ) is
displayed on the MMI
- Communication is possible for every participant
2 CR-A pick up handset - Loudspeaker set to reduced volume
- Communication is activated on the handset
3 CR-A hang up handset - Loudspeaker set to increased volume
- Ongoing call transferred to the loudspeaker
4 CR-A put the ongoing multiparty call on
hold
- Indication that the call is on hold is
displayed on the MMI
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 61/117
Step Procedure Result / Effect
5 CR-A rejoins the call from hold - Multiparty call rejoined, communication
possible
6a - none –
(network coverage breaks off)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- After network coverage returns,
CR-A in default idle mode
6b
- none –
(CR-A is being disconnected from
ongoing multiparty call) - CR-A in default idle status
6c
- none –
(CR-B terminates the ongoing
multiparty call)
4.10.4 Multi-driver communication – controller
Purpose: This test is to show that a controller can be added to a driver conference and can be called
separately via call waiting.
Precondition: Cab Radio test configuration
References:
EIRENE FRS :
§ 5.2.2.37
Step Procedure Result / Effect
1
CR-A as leading driver initiates a “multi-
drivers” call and connects other drivers (at
least two) to it
Conference established and communication is possible
2a
CR-A adds the controller to the "multi-
drivers" call using the driver conference
menu
- Call is put through and displayed at the
controller
- The controller accepts the call
- Controller added to the “multi-drivers” call
2b CR-A initiates a PTP call to a controller
using the Hold menu option or soft key
- Call is put through and displayed at the
controller
- Controller accepts the call, communication
between CR-A and the controller is possible
- The ”multi-drivers” call is on hold
(call waiting is possible)
- Communication is possible for the other
participants of the “multi-drivers” call
2c
- none –
(incoming call from Controller to CR-A
using functional number)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Controller is automatically added to the
“multi-drivers” call
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 62/117
4.11 Broadcast calls
4.11.1 Incoming voice broadcast call
Purpose: This test is to show that the Cab Radio accepts voice broadcast calls automatically and the
call can be heard on the loudspeaker or in the handset, depending on the handset state.
Precondition: Cab Radio test configuration; Broadcast groups are activated on CR-A
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.49, 5.2.2.50, 11.2.3.2
§ 4.3.1, 5.5.19
Step Procedure Result / Effect
1a
CR-A handset is in “on-hook” state
(incoming broadcast call with
eMLPP<3>)
- Broadcast call is accepted automatically
- Visual indication for broadcast service
- Group identity of the caller is displayed on the
MMI
- Incoming call can be heard in the loudspeaker
1b
CR-A handset is in “off-hook” state
(incoming broadcast call with
eMLPP<3>)
- Broadcast call is accepted automatically
- Visual indication for broadcast service
- Group identity of the caller is displayed on the
MMI
- Loudspeaker set to reduced volume
- Incoming call can be heard in the handset
2 Initiator terminates the call CR-A in default idle status
4.11.2 Leaving a voice broadcast call
Purpose: This test is to show that the Cab Radio can leave an ongoing voice broadcast call without
terminating it.
Precondition: Cab Radio test configuration; Broadcast groups are activated on CR-A
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.61i
§ 5A.3, 5.5.19
Step Procedure Result / Effect
1 - none -
(MS-A initiates VBC 200) CR-A receive voice broadcast service
2 CR-A pick up handset Broadcast call placed on the handset
3 CR-A hang up handset Broadcast call placed on the loudspeaker
4 CR-A leaves broadcast call
- Broadcast call left
- Broadcast call continues to exist on other
participants
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 63/117
4.11.3 Outgoing voice broadcast call
Purpose: This test is to show that a voice broadcast call can be initiated by the Cab Radio.
Precondition: Cab Radio test configuration; Dedicated broadcast group (e.g. 203) is activated on the Cab
Radio.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.1
§ 4.3.1, 5.5.14, 5.5.15
Step Procedure Result / Effect
1
CR-A initiates a broadcast call by
entering phone number or
using dedicated menu selection
(GID VBC 20X)
- MS-A receives the call
- VBC established
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
2 CR-A pick up handset
- Communication is activated on the handset
- CR-A has a dedicated uplink after call
establishment
- CR-A can be heard on MS-A loudspeaker
3 CR-A terminates broadcast call - Call terminated
- CR-A in default idle status
4.11.4 Moving out of the broadcast call area
Purpose: This test is to show that when the Cab Radio is in an ongoing broadcast call and it leaves
the broadcast call area the broadcast call is also left.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
§ 5.2.2.16, 5.2.2.55
Step Procedure Result / Effect
1
- none –
(MS-A initiates broadcast call VBS
200)
- Broadcast call established
- CR-A receives broadcast call and
joins the call automatically
2
- none –
(change the attenuation at the handover
machine to initiate cell change that
invokes
broadcast call area change for CR-A)
- CR-A’s broadcast call area changed
- CR-A leaves ongoing broadcast call
- Audible indication is given on the
loudspeaker
- Visual indication is displayed on the MMI
- CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 64/117
4.12 Call arbitration
4.12.1 Call arbitration – ongoing railway emergency call
Purpose:
Note:
This test is to show the call arbitration with an ongoing emergency call.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing railway emergency call (eMLPP <0> , GID 299)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) No change
1b PtP call from CR-A (eMLPP <2>)
- Ongoing call maintained
- New call not established
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>)
1e Call to Controller from CR-A (eMLPP
<3>)
1f ”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call maintained
- New call not established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 65/117
Step Procedure Result / Effect
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call maintained
- New call not established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call maintained
- Incoming call indicated but cannot be accepted
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
4.12.2 Call arbitration – ongoing high priority point-to-point call
Purpose:
Note:
This test is to show the call arbitration with an ongoing high priority point-to-point call.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing high priority point-to-point call (eMLPP <2>)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 66/117
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>)
- Ongoing call terminated
- Emergency call established
1b PtP call from CR-A (eMLPP <2>) - Ongoing call is on hold
- New call established
1c VGC 200 call from CR-A (eMLPP <2>)
Preferred Implementation:
- Ongoing call is put on hold
- New call established
Optional Implementation (If system limitations
prevent an ongoing PTP call from being put on
hold):
- Ongoing terminated
- New call established
1d VGC 555 call from CR-A (eMLPP <3>)
- Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>)
1f ”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call terminated
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call is maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call terminated
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call maintained
- New call not established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call maintained
- New call not established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>) - Ongoing call terminated
- Incoming call connected
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 67/117
Step Procedure Result / Effect
2b PtP call to CR-A (eMLPP <2>)
- Ongoing call maintained
- Incoming call indicated
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
4.12.3 Call arbitration – ongoing high priority group call between drivers in the same area
Purpose:
Note:
This test is to show the call arbitration with an ongoing high priority group call between
drivers in the same area.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing high priority group call between drivers in the same area
(eMLPP <2> , GID 200)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 68/117
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call left
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
- Ongoing call maintained
- New call not established
1d VGC 555 call from CR-A (eMLPP <3>)
1e Call to Controller from CR-A (eMLPP
<3>)
1f ”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call maintained
- New call not established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call maintained
- New call not established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 69/117
Step Procedure Result / Effect
New incoming calls
2a Emergency call to CR-A (eMLPP <0>) - Ongoing call left
- Incoming call connected
2b PtP call to CR-A (eMLPP <2>)
- Ongoing call maintained
- Incoming call indicated
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 70/117
4.12.4 Call arbitration – ongoing operational group call to drivers in the same area
Purpose:
Note:
This test is to show the call arbitration with an ongoing operational group call to drivers in
the same area.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing operational group call to drivers in the same area (eMLPP
<3> , GID 555)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call left
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call left
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call is maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call maintained
- New call not established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call left
- New call is established 1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>) - Ongoing call maintained
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 71/117
Step Procedure Result / Effect
1p VBC call from CR-A (eMLPP <4>) - New call not established
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call left
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call is maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 72/117
4.12.5 Call arbitration – ongoing call from a controller
Purpose:
Note:
This test is to show the call arbitration with an ongoing call from a controller (or
operational calls).
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing call from a controller (eMLPP <3>)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call is on hold
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call terminated
- Public Address connected
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call is maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call terminated
- Intercom connected
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call is on hold
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call is maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>) Preferred Implementation:
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 73/117
Step Procedure Result / Effect
1m VBC call from CR-A (eMLPP <3>)
- Ongoing call is put on hold
- New call established
Optional Implementation (If system limitations
prevent an ongoing PTP call from being put on
hold):
- Ongoing terminated
- New call established
1n PtP call from CR-A (eMLPP <3>) - Ongoing call is on hold
- New call established
1o VGC 20X call from CR-A (eMLPP <4>) - Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>) - Ongoing call is on hold
- New call established
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 74/117
4.12.6 Call arbitration – ongoing “other drivers on same train” call
Purpose:
Note:
This test is to show the call arbitration with an ongoing “other drivers on same train” call.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing “other drivers on same train” call as leading driver (Multi-
driver call with eMLPP <3>)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the “other drivers on same train” call)
- New call established
1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>)
- Ongoing call is on hold
- New call established
1f ”Other drivers same train” call from
CR-A
- Ongoing call maintained
- New call not established
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call is on hold
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>) Preferred Implementation:
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 75/117
Step Procedure Result / Effect
1m VBC call from CR-A (eMLPP <3>)
- Ongoing call is put on hold
- New call established
Optional Implementation (If system limitations
prevent an ongoing PTP call from being put on
hold):
- Ongoing terminated
- New call established
1n PtP call from CR-A (eMLPP <3>) - Ongoing call is on hold
- New call established
1o VGC 20X call from CR-A (eMLPP <4>)
- Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>) - Ongoing call terminated
- Incoming call connected
2b PtP call to CR-A (eMLPP <2>)
- Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the “other drivers on same train” call)
- Incoming call connected
2c VGC 200 call to CR-A (eMLPP <2>) - Ongoing call terminated
- Incoming call connected
2d VGC 555 call to CR-A (eMLPP <3>) - Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
- Ongoing call maintained
- Controller has joined the ongoing call
2f ”Other drivers same train” call to CR-A Not possible
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 76/117
4.12.7 Call arbitration – ongoing chief conductor call (over radio link)
Purpose:
Note:
This test is to show the call arbitration with an ongoing “chief conductor” call over radio
link.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing “chief conductor” call (over radio link MLPP <3>)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call is on hold
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call terminated
- New call connected to Public Address
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call terminated
- New call connected to Intercom
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link) No change
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>) Preferred Implementation:
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 77/117
Step Procedure Result / Effect
1m VBC call from CR-A (eMLPP <3>)
- Ongoing call is put on hold
- New call established
Optional Implementation (If system limitations
prevent an ongoing PTP call from being put on
hold):
- Ongoing terminated
- New call established
1n PtP call from CR-A (eMLPP <3>) - Ongoing call is on hold
- New call established
1o VGC 20X call from CR-A (eMLPP <4>)
- Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 78/117
4.12.8 Call arbitration – ongoing voice group call (eMLPP<3>)
Purpose:
Note:
This test is to show the call arbitration with an ongoing voice group call with eMLPP<3>.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing voice group call (eMLPP <3> , GID 20x)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call left
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call left
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link) Not possible
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call left
- New call established 1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>) - Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 79/117
Step Procedure Result / Effect
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call left
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 80/117
4.12.9 Call arbitration – ongoing voice broadcast call (eMLPP<3>)
Purpose:
Note:
This test is to show the call arbitration with an ongoing voice broadcast call with
eMLPP<3>.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing voice broadcasting call (eMLPP <3> , GID 2xx)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established
1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established 1f ”Other drivers same train” call from
CR-A
1g
Call to the Public Address from CR-A
(using UIC intercom link)
For mobile terminated VBC
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i
Call to the Intercom from CR-A
(using UIC intercom link)
For mobile terminated VBC
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link) - Not possible
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>) - Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 81/117
Step Procedure Result / Effect
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- Incoming call connected
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 82/117
4.12.10 Call arbitration – ongoing point-to-point call (eMLPP<3>)
Purpose:
Note:
This test is to show the call arbitration with an ongoing point-to-point call with
eMLPP<3>.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing point-to-point call (eMLPP <3>)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call is on hold
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call terminated
- New call connected to Public Address
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call terminated
- New call connected to Intercom
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call is on hold
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>) Preferred Implementation:
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 83/117
Step Procedure Result / Effect
1m VBC call from CR-A (eMLPP <3>)
- Ongoing call is put on hold
- New call established
Optional Implementation (If system limitations
prevent an ongoing PTP call from being put on
hold):
- Ongoing terminated
- New call established
1n PtP call from CR-A (eMLPP <3>) - Ongoing call is on hold
- New call established
1o VGC 20X call from CR-A (eMLPP <4>)
- Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 84/117
4.12.11 Call arbitration – ongoing voice group call (eMLPP<4>)
Purpose:
Note:
This test is to show the call arbitration with an ongoing voice group call with eMLPP<4>.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing other group call (eMLPP <4> , GID 20x)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call left
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call left
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call left
- New call established
(or no change if no UIC Intercom link present)
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call left
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call left
- New call established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 85/117
Step Procedure Result / Effect
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call left
- Incoming call connected
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
- Ongoing call maintained
- Incoming call indicated
2j VGC 20X call to CR-A (eMLPP <3>)
- Ongoing call left
- Incoming call connected 2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
- Ongoing call maintained
- Incoming call indicated 2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 86/117
4.12.12 Call arbitration – ongoing voice broadcast call (eMLPP<4>)
Purpose:
Note:
This test is to show the call arbitration with an ongoing voice broadcast call with
eMLPP<4>.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing voice broadcasting call (eMLPP <4> , GID 2xx)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established
1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established 1f ”Other drivers same train” call from
CR-A
1g
Call to the Public Address from CR-A
(using UIC intercom link)
For mobile terminated VBC
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established
1i
Call to the Intercom from CR-A
(using UIC intercom link)
For mobile terminated VBC
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of 1m VBC call from CR-A (eMLPP <3>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 87/117
Step Procedure Result / Effect
1n PtP call from CR-A (eMLPP <3>) the voice broadcast call)
- New call established 1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- Incoming call connected
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
- Ongoing call maintained
- Incoming call indicated
2j VGC 20X call to CR-A (eMLPP <3>) - Ongoing call terminated or left
(depends on whether CR-A was the initiator of
the voice broadcast call)
- Incoming call connected
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
- Ongoing call maintained
- Incoming call indicated 2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 88/117
4.12.13 Call arbitration – ongoing point-to-point call (eMLPP<4>)
Purpose:
Note:
This test is to show the call arbitration with an ongoing point-to-point call with
eMLPP<4>.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing point-to-point call (eMLPP <4>)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call terminated
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call terminated
- New call connected to Public Address
(or no change if no UIC Intercom link present)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call is on hold
- New call established
(or no change if no UIC Intercom link present)
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call terminated
- New call connected to Intercom
(or no change if no UIC Intercom link present)
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call is on hold
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call terminated
- New call established 1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>) Preferred Implementation:
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 89/117
Step Procedure Result / Effect
1p VBC call from CR-A (eMLPP <4>)
- Ongoing call is put on hold
- New call established
Optional Implementation (If system limitations
prevent an ongoing PTP call from being put on
hold):
- Ongoing terminated
- New call established
1q PtP call from CR-A (eMLPP <4>) - Ongoing call is on hold
- New call established
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated
- Incoming call connected
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
- Ongoing call maintained
- Incoming call indicated
2j VGC 20X call to CR-A (eMLPP <3>)
- Ongoing call terminated
- Incoming call connected 2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
- Ongoing call maintained
- Incoming call indicated 2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 90/117
4.12.14 Call arbitration – ongoing shunting emergency call
Purpose:
Note:
This test is to show the call arbitration with an ongoing shunting emergency call.
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration;
CR-A is in an ongoing shunting emergency call (eMLPP <0> , GID 599)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) No change
1b PtP call from CR-A (eMLPP <2>)
- Ongoing call maintained
- New call not established 1c Call to Controller from CR-A (eMLPP
<3>)
1d Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1e Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1f Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1g Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1h PtP call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established 1i PtP call from CR-A (eMLPP <4>)
New incoming calls
2a PtP call to CR-A (eMLPP <2>) - Ongoing call maintained
- Incoming call indicated but cannot be accepted 2b Call from Controller to CR-A (eMLPP
<3>)
2c Call to CR-A’s Public Address
(over radio link, eMLPP <3>) - Ongoing call maintained
- Incoming call rejected 2d
Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2e Call to CR-A from the Intercom
(using UIC intercom link)
- Ongoing call maintained
- Incoming call indicated but cannot be accepted
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 91/117
Step Procedure Result / Effect
2f PtP call to CR-A (eMLPP <3>)
2g PtP call to CR-A (eMLPP <4>)
2h Shunting Emergency call to CR-A
(eMLPP <0>)
2i SGC 500 call to CR-A (eMLPP <3>)
2j SGC 50X call to CR-A (eMLPP <3>)
4.12.15 Call arbitration – ongoing default group call in shunting mode
Purpose:
Note:
This test is to show the call arbitration with an ongoing group call in shunting mode (GID
500).
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration; Shunting mode;
CR-A is in an ongoing default group call in shunting mode (eMLPP <3> , GID 500)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>)
- Ongoing call left
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c Call to Controller from CR-A (eMLPP
<3>)
1d Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1e Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1f Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1g Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1h PtP call from CR-A (eMLPP <3>) - On-going call left
- New call established
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 92/117
Step Procedure Result / Effect
1i PtP call from CR-A (eMLPP <4>) - Ongoing call maintained
- New call not established
1j SGC 500 call from CR-A (eMLPP <3>) No change
New incoming calls
2a PtP call to CR-A (eMLPP <2>) - Ongoing call left
- Incoming call connected
2b Call from Controller to CR-A (eMLPP
<3>)
- Ongoing call maintained
- Incoming call indicated
2c Call to CR-A’s Public Address
(over radio link, eMLPP <3>) - Ongoing call maintained
- Incoming call rejected 2d
Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2e Call to CR-A from the Intercom
(using UIC intercom link) - Ongoing call maintained
- Incoming call indicated 2f PtP call to CR-A (eMLPP <3>)
2g PtP call to CR-A (eMLPP <4>)
2h Shunting Emergency call to CR-A
(eMLPP <0>)
- Ongoing call left
- Incoming call connected
4.12.16 Call arbitration – ongoing dedicated group call in shunting mode
Purpose:
Note:
This test is to show the call arbitration with an ongoing dedicated group call in shunting
mode (GID 50X).
Intercom / Public Address / Chief Conductor (with UIC Intercom link) has no eMLPP but
has priorities according to EIRENE SRS §5A.1.1 and §5A.1.2
Precondition: Cab Radio test configuration; Shunting mode;
CR-A is in an ongoing dedicated group call in shunting mode (eMLPP <3> , GID
501-529)
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.4.4, 5.2.4.5, 5.2.4.6, 5.2.4.7
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 93/117
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>)
- Ongoing call left
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c Call to Controller from CR-A (eMLPP
<3>)
1d Call to the Public Address from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Public Address connected to the handset
(or no change if no UIC Intercom link present)
1e Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- New call not established
1f Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call transferred to the loudspeaker
- Intercom connected to the handset
(or no change if no UIC Intercom link present)
1g Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
(or no change if no UIC Intercom link present)
1h PtP call from CR-A (eMLPP <3>) - On-going call left
- New call established
1i PtP call from CR-A (eMLPP <4>) - Ongoing call maintained
- New call not established
1j SGC 50X call from CR-A (eMLPP <3>) No change
New incoming calls
2a PtP call to CR-A (eMLPP <2>) - Ongoing call left
- Incoming call connected
2b Call from Controller to CR-A (eMLPP
<3>)
- Ongoing call maintained
- Incoming call indicated
2c Call to CR-A’s Public Address
(over radio link, eMLPP <3>) - Ongoing call maintained
- Incoming call rejected 2d
Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2e Call to CR-A from the Intercom
(using UIC intercom link) - Ongoing call maintained
- Incoming call indicated 2f PtP call to CR-A (eMLPP <3>)
2g PtP call to CR-A (eMLPP <4>)
2h Shunting Emergency call to CR-A
(eMLPP <0>)
- Ongoing call left
- Incoming call connected
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 94/117
4.13 Railway emergency calls
4.13.1 Incoming railway emergency call
Purpose: This test is to show that when the Cab Radio receives an incoming railway emergency call
automatically joins the call.
Precondition: Cab Radio test configuration; CR-A and MS-A in Train Mode and later in Shunting Mode.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.4, 5.2.2iii, 5.2.2.56, 5.2.2.60, 10.4.5, 13.2.4.1, 13.3.1
§ 4.3.1, 4.3.4, 5.5.4, 5.5.19, 13.4.1, 13.4.2
Step Procedure Result / Effect
1 - none -
(MS-A initiates „railway emergency
call”)
- CR-A receives and joins call automatically
- Audible indication (different to common
VGCS) is given on the loudspeaker for 5
seconds
- Visual indication is displayed on the MMI
including group identity
(299/599 or textual translation)
- Caller can be heard on the loudspeaker
- Indication to use PTT to talk is displayed on
the MMI
2 CR-A pick up handset - Loudspeaker set to reduced volume
- Communication is activated on the handset
3 CR-A hangs-up handset
- Loudspeaker set to increased volume
- Ongoing call transferred to the loudspeaker
- MS-A can be heard on CR-A loudspeaker
4 CR-A tries to leave or terminate the
railway emergency call
- CR-A cannot leave or terminate the „railway
emergency call”
5 - none -
(MS-A terminates emergency call)
- Emergency call terminated
- CR-A in default idle status
6 Check CR-A’s VGCS/VBS subscription
state via MMI
- A list with all GIDs from the SIM Card is
presented except for GID 299 and 599
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 95/117
4.13.2 Outgoing railway emergency call
Purpose: This test is to show that a railway emergency call is initiated and managed by the Cab
Radio using emergency access and that this established with eMLPP <0> (railway
emergency). The functional number of the Cab Radio is transmitted to the controller when
sending a train emergency call.
Precondition: Cab Radio test configuration. CR-A in Train Mode and later in Shunting Mode.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.4, 5.2.2iii, 5.2.2.18, 5.2.2.20, 5.2.2.21, 5.2.2.22, 5.2.2.24, 5.2.2.60, 5.2.4.9, 9.3.2,
10.2.1, 10.2.2, 13.1.4, 13.1.5, 13.2.2.1, 13.2.2.4, 13.2.2.6, 13.2.3.1, 13.2.4.1
§ 4.3.4, 4.4.3, 5.3.5, 5.3.6, 5.5.4, 5.5.5, 10.2.1, 13.2.2, 13.3.1
Step Procedure Result / Effect
1a CR-A initiates „railway emergency
call” using “Emergency button”
(handset is off-hook)
- Dialling or status indication for dialling
starts within 2 seconds
- An attention sound with reduced volume is in
the loudspeaker for 5 seconds while the call is
initiated
1b CR-A initiates „railway emergency
call” using “Emergency button”
(handset is on-hook)
- Dialling or status indication for dialling
starts within 2 seconds
- An attention sound with increased volume is in
the loudspeaker for 5 seconds while the call is
initiated
2 - none -
- Permanent visual indication is displayed on the
MMI;
- Emergency call established with eMLPP <0>
- GID, GCA, Call Type (and FN of CR-A)
is displayed at the controller
- Indication to use PTT to talk is displayed on the
MMI
3
(pick up handset if it is on-hook)
CR-A press PTT button
(uplink is free)
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “You can talk”) is
- displayed on the MMI
- CR-A has a dedicated uplink until the PTT
button is released or the network timer expires
- CR-A can be heard on MS-A loudspeaker
4 Release PTT on CR-A
- Audible indication is given on the loudspeaker
- Indication to use PTT to talk is given
to the driver on the MMI
5 CR-A hangs-up handset
- Loudspeaker set to increased volume
- Ongoing call transferred to the loudspeaker
- MS-A can be heard on CR-A loudspeaker
6a CR-A terminates emergency call - Emergency call terminated
- Visual indication - regarding the call - cleared
- CR-A in default idle status 6b - none –
(Controller terminates emergency call)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 96/117
Step Procedure Result / Effect
6c
- none –
(network terminates the call
after predefined time of no speech)
4.13.3 Deleted
4.13.4 Railway emergency call – leaving group call area
Purpose: This test is to show that the Cab Radio leaves the “railway emergency call” after moving
out of the group call area.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
§ 5.2.2.23, 13.2.4.2
Step Procedure Result / Effect
1a
- none –
(MS-A initiates “railway emergency
call”)
CR-A receives and joins the call automatically
1b CR-A initiates “railway emergency
call” MS-A receives and joins the call automatically
2
- none –
(change of attenuation at the handover
machine to initiate a cell change that
invokes group call area change for
CR-A)
- CR-A leaves emergency call
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Emergency call continues at MS-A
- CR-A returns in default idle status
4.13.5 Railway emergency call – entering group call area
Purpose: This test is to show that the Cab Radio when entering a group call area with an ongoing
“railway emergency call” automatically receives and joins it.
Precondition: Cab Radio test configuration. Ongoing “train emergency call” is present in a different
group call area than CR-A. A VGC 20X shall be present in both group call areas.
References:
EIRENE FRS :
§ 3.5.6, 13.2.2.7
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 97/117
Step Procedure Result / Effect
1a - none -
CR-A is in idle mode CR-A is in idle mode
1b - none -
CR-A is in an ongoing PtP call with
eMLPP <3>
CR-A is in an ongoing PtP call
1c
- none -
CR-A is in an ongoing, mobile
terminated VGC 20X with eMLPP
<3> as listener (no uplink)
CR-A is in an ongoing, mobile terminated VGC 20X
as listener (no uplink)
1d
- none -
CR-A is in an ongoing, mobile
terminated VGC 20X with eMLPP
<3> as talker (PTT pressed)
CR-A is in an ongoing, mobile terminated VGC 20X
as talker (PTT pressed)
2
- none -
(change of attenuation at the
handover machine to initiate a cell
change that invokes group call area
change for CR-A)
CR-A enters the group call area where the ongoing
“railway emergency call” is present
3 - none -
- CR-A receives and joins the
emergency call automatically
- Other ongoing calls are terminated or left
immediately
- An attention sound is in the loudspeaker for 5
seconds
- Visual indication is displayed on the MMI
including group identity
- Caller can be heard on driver’s loudspeaker
- Indication to use PTT to talk is
given to the driver on the MMI
4.13.6 Railway emergency call – re-dial after unsuccessful call
Purpose: This test is to show that the Cab Radio shall automatically re-attempt call initiation for 30
seconds when a “railway emergency call” establishment is unsuccessful. If the call cannot
be initiated within this time an audible and visual indication is provided to the driver.
Precondition: Cab Radio test configuration.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.25, 13.2.2.3, 13.2.2.3i, 13.2.2.3ii
§ 4.3.5, 4.3.6, 4.4.3
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 98/117
Step Procedure Result / Effect
1 CR-A initiates „ railway emergency
call”
(call cannot be established)
(after approx. 2 seconds)
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI about
the unsuccessful emergency call establishment
status
2
- none –
(CR-A automatically tries re-
establishing
the emergency call for 30 seconds)
- Audible indication is given on the loudspeaker
- Visual indication (e.g. “trying to connect the
call”) is displayed on the MMI
3 - none –
(after 30 seconds)
- CR-A gives up trying to establish the
emergency call Audible indication is given on
the loudspeaker
- Visual indication is displayed on the MMI
- CR-A in default idle status
4.13.7 eREC backward compatibility
Purpose: This test is to show that eREC capable Cab Radio can operate in either eREC or non-eREC
capable network.
Precondition: Cab Radio test configuration. CR-A has eREC functionalities. Two GSM-R networks
available, one with eREC capabilities and another without eREC capabilities. CR-A camped
on the eREC capable network and has eREC registration first without and later with active
Sector Identity(-ies). ABIS trace or protocol analyser.
References:
EIRENE SRS :
§ 4.3.4, 13A.2.2
Step Procedure Result / Effect
1a (CR-A in eREC Standby Mode –
no Sector Identities are active)
CR-A initiates emergency call
- Emergency call initiated by dialling 299 / 599
- REC call established
1b (CR-A in eREC Mode – at least
one Sector Identity is active)
CR-A initiates emergency call
- Emergency call initiated by dialling S299 / S599
(S is the first active Sector Identity of CR-A)
- eREC call established
1c
(CR-A in eREC Mode – at least
one Sector Identity is active)
- none -
(incoming eREC call to CR-A with the
same Sector Identity activated on CR-
A)
CR-A receives and joins emergency call automatically
2 Initiator terminates the emergency call Call terminated
3 CR-A change network to non-eREC
network
- Network changed
- CR-A in default idle mode
4a - none -
(incoming REC call to CR-A) CR-A receives and joins emergency call automatically
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 99/117
Step Procedure Result / Effect
4b CR-A initiates emergency call - Emergency call initiated by dialling 299 / 599
- REC call established
5 CR-A change network to eREC
network
- Network changed
- CR-A in eREC Standby Mode
- No Sector Identities are active on CR-A
4.14 Shunting mode
4.14.1 Entering shunting mode – during ongoing call
Purpose: This test shall verify that the change from train radio mode into shunting mode is not
possible during an on-going call involving the Cab radio.
Precondition: Cab Radio test configuration. CR-A in train mode.
References:
EIRENE FRS :
§ 5.2.2.65
Step Procedure Result / Effect
1a (MS-A initiates a PTP call to CR-A)
CR-A accepts the call
Call established, communication is possible 1b (MS-A initiates a group call)
CR-A accepts the call
1c (MS-A initiates a broadcast call)
CR-A accepts the call
2 CR-A activates shunting mode using
MMI menu (if available)
Activation of shunting mode not possible
CR-A maintains the ongoing call
4.14.2 Entering shunting mode – idle mode
Purpose: This test shall verify that the change from train radio mode into shunting mode is supported
by the Cab Radio.
Precondition: Cab Radio test configuration. CR-A in train mode and has train number registered.
References:
EIRENE FRS :
EIRENE SRS :
§ 4.2.4, 14.2.2
§ 4.3.4, 5.3.13, 14.4.1, 14.5.2
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 100/117
Step Procedure Result / Effect
1 CR-A activates shunting mode
using MMI menu
- CR-A performs the following steps during
transition:
All active GIDs deactivated
(except GID 299)
GID 599 activated
Emergency button assigned to GID 599
GID 299 deactivated
- Display is according to shunting mode
(see user’s manual)
- CR-A in default idle status
2a
- none –
(MS-A initiates PTP call to CR-A by
TN)
CR-A does not receive the call (TN deregistered)
2b - none –
(MS-A initiates group call 200) - Group call GID 200/299 is established
- Group call is not received by CR- A
- CR-A in default idle status 2c
- none –
(MS-A initiates train emergency call
299)
2d
- none –
(MS-B initiates shunting group call
500) - CR-A receives and accepts the call
automatically.
2e
- none –
(MS-B initiates shunting emergency
call)
4.14.3 Shunting registration
Purpose: This test is to show that the Cab Radio provides options for selecting shunting area and
group (and also role in dedicated shunting group) during shunting registration procedure.
Precondition: Cab Radio test configuration. CR-A in shunting mode.
References:
EIRENE FRS :
EIRENE SRS :
§ 14.3.1
§ 11.3.5, 14.4.6, 14.5.2
Step Procedure Result / Effect
1 CR-A selects MMI menu for changing
shunting registration Shunting registration menu is displayed on the MMI
2 CR-A changes the shunting area and
shunting group using MMI menu
- Only valid group ID (501-529) can be entered
or selected from a list
3
CR-A changes the shunting group to a
dedicated group where ongoing
shunting group call is present
(previously set up by MS-A) using
MMI menu
- CR-A enters the selected shunting group
- New CT6 registration carried out
- CR-A automatically joins ongoing group call
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 101/117
Step Procedure Result / Effect
4 CR-A leaves ongoing group call - Ongoing group call left
- CR-A in default idle status
5 CR-A changes the shunting area
using MMI menu
- CR-A enters the selected shunting area
- New CT6 registration carried out
4.14.4 Shunting registration – failed registration
Purpose: This test is to show that a failed registration is indicated to the user.
Precondition: Cab Radio test configuration. CR-A in shunting mode and in a defined group area with a
registered functional identity. Prepare possibility to produce registration failure (e.g.
network configuration denies a specific shunting group).
References:
EIRENE FRS :
EIRENE SRS :
§ 11.3.2.4i
§ 14.4.7
Step Procedure Result / Effect
1 CR-A selects MMI menu for changing
shunting registration Shunting registration menu is displayed on the MMI
2 CR-A changes call area and group
number using MMI menu
- Automatic (de-) registration of the FN for group
number is attempted (de-) registration NOT
successful)
- Indication is given to the user of the failure
4.14.5 Shunting group activation
Purpose: This test is to show that during shunting operation, besides the emergency group ID 599,
only one group ID can be activated.
Precondition: Cab Radio test configuration. Shunting group ID 500, 50X are available;
References:
EIRENE SRS :
§ 14.4.9
Step Procedure Result / Effect
1
(CR registered to shunting GID 500)
CR-A changes to a dedicated shunting
group (GID 50X)
CR-A changes to dedicated shunting group 50X
2 – none –
(MS-A initiate a SGC in GID 500)
- Shunting group call established
- CR-A in default idle status
3
– none –
(MS-A initiate a shunting emergency
call)
- Shunting emergency call established
- CR-A joins the emergency call automatically
4 – none –
(MS-A initiate a SGC in GID 50X)
- Shunting group call established
- CR-A joins the call GID 50X automatically
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 102/117
4.14.6 Shunting area change – joining ongoing shunting emergency call
Purpose: This test is to show that the Cab Radio joins an ongoing shunting emergency call
automatically when entering into an area with an ongoing shunting emergency call.
Precondition: Cab Radio test configuration; CR-A in shunting mode;
References:
EIRENE FRS :
§ 13.2.2.7
Step Procedure Result / Effect
1
CR-A enters a shunting area with
an ongoing shunting emergency call
(GID 599)
- CR-A changes the area and joins the
ongoing call automatically
- Audible and visual indication of the call
- Initiator of the emergency can be heard on CR-
A
4.14.7 Shunting area change – during shunting group call
Purpose: This test is to show that the Cab Radio leaves the shunting group call after moving out of
the group call area.
Precondition: Cab Radio test configuration. CR-A in shunting mode.
References:
EIRENE FRS :
§ 5.2.2.55
Step Procedure Result / Effect
1
- none –
(MS-A initiates shunting group call
500)
CR-A receives and accepts call automatically
2
Change of attenuation at the handover
machine to initiate a cell change that
invokes group call area change for
CR-A
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- CR-A leaves ongoing group call
- Shunting group call remains ongoing
for the other participants
4.14.8 Exiting shunting mode
Purpose: This test is to show that the Cab Radio can leave shunting radio mode and enter train radio
mode.
Precondition: Cab Radio test configuration; CR-A in shunting mode;
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.64
§ 14.4.15, 14.4.16, 14.4.18, 14.4.19
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 103/117
Step Procedure Result / Effect
1 CR-A initiates system change to
train radio system using MMI menu
- CR-A performs the following steps during
transition:
All active GIDs deactivated
(except GID 599)
GID 299 activated
Emergency button assigned to GID 299
GID 599 deactivated
GIDs that were active before entering
shunting mode are re-activated
- Display is according to train mode
(see user’s manual)
- CR-A in default idle status
2a - none –
(MS-A initiates shunting group call)
- Shunting group call is established
- CR-A does not receive the call
- CR-A in default idle status (train radio system)
2b - none –
(MS-B initiates PTP call to CR-A by
FN)
- CR-A receives the call (FN registered)
2c - none –
(MS-B initiates group call 200) - CR-A receives and accepts the call
automatically. 2d
- none –
(MS-B initiates emergency call 299)
2e - none –
(MS-A initiates shunting emergency
call)
- Shunting emergency call is established
- CR-A does not receive the call
- CR-A in default idle status (train radio system)
4.14.9 Exiting shunting mode – during shunting group call
Purpose: This test is to show that the Cab Radio won’t terminate an ongoing shunting group call if
the function for system change to train mode is activated. The system change procedure
can result in two different ways and it is an implementation option.
Precondition: Cab Radio test configuration; CR-A in shunting mode;
References:
EIRENE SRS :
§ 14.4.14
Step Procedure Result / Effect
1a - none –
(MS-A initiates shunting group call)
- Shunting group call is established
- CR-A and MS-B join the call automatically
1b CR-A initiates shunting group call - Shunting group call is established
- MS-A and MS-B join the call automatically
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 104/117
Step Procedure Result / Effect
2
(MS-A takes the uplink)
CR-A initiates system change to
train radio system using MMI menu
- Shunting group call left
- Changing to train radio mode
(shunting group call remains active,
MS-A and MS-B can communicate)
- CR-A in default idle status (train radio system)
- Changing to train radio mode is not possible
until shunting group call terminated or left
- CR-A stays connected to the ongoing group call
4.14.10 Storage of shunting data
Purpose: This test is to show that shunting data is stored in non-volatile memory to be used for the
start-up procedure.
Precondition: Cab Radio test configuration. CR-A in shunting mode and registered to a dedicated
shunting group.
References:
EIRENE SRS :
§ 14.4.11
Step Procedure Result / Effect
1 Power-off CR-A CR-A powered off
2 Power-on CR-A
- CR-A performs its normal start-up
- CR-A is in default train idle status
or in default idle status.
- Shunting data are the same as was before
4.14.11 Group call in shunting mode
Purpose: This test is to show that a voice group call can be initiated in shunting mode by the Cab
Radio.
Precondition: Cab Radio test configuration. Cab Radio and MS-A in shunting mode and registered to the
same dedicated shunting group.
References:
EIRENE FRS :
§ 5.2.2.9, 5.2.2.60
Step Procedure Result / Effect
1
CR-A initiates a voice group call by
entering phone number or
using dedicated menu selection or
by pressing PTT
- MS-A receives the call
- SGC established with eMLPP <3>
- Audible indication is given on the loudspeaker
- Visual indication is displayed on the MMI
- Indication to use PTT to talk is displayed on the
MMI
- Incoming audio is connected to the loudspeaker
until the driver picks up the handset
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 105/117
Step Procedure Result / Effect
2 CR-A pick up handset and press PTT
- Loudspeaker set to reduced volume
- Communication is activated on the handset
- CR-A has a dedicated uplink until the PTT
button is released or the network timer expires
- CR-A can be heard on MS-A loudspeaker
3 CR-A release PTT Indication to use PTT to talk is displayed on the MMI
4 CR-A press PTT button
(uplink is busy)
- Audible indication is given on the loudspeaker
- Visual indication (e.g. “Uplink busy”) is
displayed on the MMI
5 CR-A press PTT button
(uplink is free)
- Audible indication is given on the loudspeaker
- Visual indication (e. g. “You can talk”) is
displayed on the MMI
- CR-A can be heard on MS-A loudspeaker
6 CR-A release PTT Indication to use PTT to talk is displayed on the MMI
7 CR-A terminates group call - Call terminated
- CR-A in default idle status
4.14.12 Link Assurance Signal
Purpose: This test is to show that the Cab Radio can receive the Link Assurance Signal (LAS)
during a shunting group call. Incoming and outgoing shunting emergency calls are
automatically takes priority over the link assurance signal
Precondition: Cab Radio test configuration. CR-A in shunting mode with dedicated shunting group
activation. MS-A is an operational shunting radio that supports link assurance signal
(LAS).
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.63, 5.2.2.66, 13.1.8, 14.2.9, 14.2.12, 14.4.5
§ 14.7.16, 14.7.17
Step Procedure Result / Effect
1 - none –
(MS-A initiates shunting group call
501)
CR-A receives shunting group call GID 501 and
accepts the call automatically
2 - none –
(MS-A start LAS transmission)
- Shunting group call 501 ongoing
- LAS can be heard on CR-A’s loudspeaker
3a - none –
(MS-B initiates „shunting emergency
call”) - LAS interrupted on CR-A’s loudspeaker
- CR-A receives and accepts call automatically
3b CR-A initiates „shunting emergency
call”
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 106/117
4.15 Call confirmation
4.15.1 Emergency call confirmation
Purpose: This test is to show that the Cab Radio uses the correct functional identity in the process of
railway emergency call confirmation as well as specific CHPC tags. Every registration
situation (Cases a, b, c, d, e) has to be created and all test steps must be carried out and
analysed.
Precondition: Cab Radio test configuration. Cab radio trace or protocol analyser. CR-A in train mode
and later in shunting mode according to registration situations.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.58, 13.4.2, 13.4.3, 13.4.5, 13.4.6, 13.4.9, 14.2.11, 14.4.7
§ 13.5.2, 13.5.3, 13.5.4, 13.5.5, 13.5.6, 13.5.7, 13.5.9, 13.5.10
Case
Train
number
(CT2)
Engine
number (CT3)
Coach number
(CT4)
Shunting registration
(CT6)
SETUP message
Tag5
a not registered not registered not registered not registered Empty (00)
b not registered not registered registered not registered Coach Number (CT4)
c not registered registered not registered not registered Engine Number (CT3)
d registered registered not registered not registered Train Number (CT2)
e registered not registered registered not registered
f not registered registered not registered registered Shunting
registration (CT6)
Step Procedure Result / Effect
1a - none –
(incoming emergency call to CR-A)
Call established, communication is possible
1b CR-A initiates emergency call
1c
(Change SIM Card field EFCallConfC –
PL_ACK to eMLPP <2>)
CR-A initiates VGCS 200 with eMLPP
<2>
1d
(Enable CHPC flag for VGCS 20X via
network settings)
CR-A initiates VGCS 20X
2a - none –
(initiator terminates emergency call)
CR-A in default idle status 2b CR-A terminates emergency call
2c CR-A terminates VGCS 200
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 107/117
Step Procedure Result / Effect
2d CR-A terminates VGCS 20X
3
- none –
(CR-A initiates PTP call for emergency
call confirmation in the background)
- Confirmation data cannot be modified by the
user
- Call initiated after random time (T_RAN)
- Call initiated by short code “1612”
- Call has eMLPP <4>
- CHPC is sent by UUS1
Tag2 (incoming call) or Tag3 (outgoing call) contains:
- duration of the call (T_DUR)
- relative time of termination (T_REL)
- priority level of call (PL_CALL)
- cause of termination (CAUSE)
- group call reference (GC_REF)
Tag5 contains:
a) Empty (no FN registered)
b) Coach Number (CT4)
c) Engine Number (CT3)
d-e) Train Number (CT2)
f) Shunting registration (CT6)
(optionally Tag2/Tag3 and Tag5 can be combined)
4 - none –
CR-A receives RELEASE COMPLETE message by
UUIE with positive confirmation (CAUSE 0x00) in
Tag2/Tag3
4.15.2 Emergency call confirmation – group call area change
Purpose: This test is to show that the Cab Radio starts emergency call confirmation after leaving the
group call area. The test has to be conducted in Train Radio Mode and after that in
Shunting Radio Mode.
Precondition: Cab Radio test configuration. Cab radio trace or protocol analyser. CR-A in train mode
and later in shunting mode.
References:
EIRENE FRS :
§ 13.4.3
Step Procedure Result / Effect
1a - none –
(incoming emergency call to CR-A) Call established, communication is possible
1b CR-A initiates emergency call
2 CR-A leaves Group Call Area
(in the new GCA group call is not active)
CR-A leaves ongoing emergency call
CR-A in default idle status
3
- none –
(CR-A initiates PTP call for emergency
call confirmation in the background)
CR-A sends confirmation with CAUSE 0x00
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 108/117
4.15.3 Emergency call confirmation – network or power loss
Purpose: This test is to show that the Cab Radio starts emergency call confirmation after power loss
or network loss if it was shorter than 5 minutes. The test has to be conducted in Train
Radio Mode and after that in Shunting Radio Mode.
Precondition: Cab Radio test configuration. Cab radio trace or protocol analyser. CR-A in train mode
and later in shunting mode.
References:
EIRENE FRS :
§ 13.4.4
Step Procedure Result / Effect
Network loss
1a - none –
(incoming emergency call to CR-A) Call established, communication is possible
1b CR-A initiates emergency call
2 - none –
(interrupt network coverage for CR-A)
- CR-A leaves emergency call
- Call for emergency call confirmation
cannot be established
3a
- none –
(restore network coverage for CR-A
t < 5 minutes)
- Call for emergency call confirmation initiated
- CR-A sends confirmation with CAUSE 0x02
(radio link error)
3b
- none –
(restore network coverage for CR-A
t > 5 minutes)
Call for emergency call confirmation not initiated
Power loss
4a - none –
(incoming emergency call to CR-A) Call established, communication is possible
4b CR-A initiates emergency call
5a
Power-off CR-A
(emergency call terminated while CR-A
is powered off)
- CR-A leaves ongoing emergency call
- CR-A is powered off
5b
CR-A terminates emergency call and is
switched off (controlled power off
according to [1])
- CR-A terminates ongoing emergency call
- CR-A is (controlled) powered off
and during that time:
- Call for emergency call confirmation initiated
- CR-A sends confirmation with CAUSE 0x00
(no error)
6a Power-on CR-A
- Call for emergency call confirmation initiated
- CR-A sends confirmation with CAUSE 0x01
(loss of power)
6b Power-on CR-A CR-A in default idle status
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 109/117
5 EIRENE Requirements for Cab Radio:
Mandatory for Interoperability – optional components
5.1 Public Address
5.1.1 Public Address – incoming call
Purpose: This test is to show that the Cab Radio can receive and join an incoming call and
terminate communication involving the Cab Radio’s Public Address system.
Precondition: Cab Radio test configuration. Public Address has a registered FN.
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.71, 5.2.2.73, 5.2.2.74
§ 5.6.1
Step Procedure Result / Effect
1
- none –
(MS-A initiate call with eMLPP <3>
to CR-A’s Public Address by FN)
- Call is established and connected to Public
Address
- Indication is given to the driver that CR-A is
busy
- MS-A can be heard on the loudspeaker
of Public Address
2 CR-A picks up handset Driver of CR-A joins the communication as a listener
or as stated in [1]
3 CR-A initiates another call - Communication between MS-A and Public
Address terminated
- New call initiated
5.1.2 Call arbitration – ongoing public address call
Purpose: This test is to show the call arbitration with an ongoing public address call using UIC
intercom link.
Precondition: Cab Radio test configuration; CR-A is in an ongoing call with its Public Address using
UIC intercom link;
References:
EIRENE SRS :
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call terminated
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 110/117
Step Procedure Result / Effect
1f ”Other drivers same train” call from
CR-A
- New call established
1g Call to the Public Address from CR-A
(using UIC intercom link) No change
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
Preferred Implementation:
- Ongoing call maintained
- New call established
Optional Implementation:
- Ongoing call maintained
- New call not established
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call not established
1j Call to the Chief Conductor from CR-A
(over radio link) Not possible
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call terminated
- New call established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
1r Shunting Emergency call from CR-A
(eMLPP <0>)
1s SGC 500 call from CR-A (eMLPP <3>)
1t SGC 50X call from CR-A (eMLPP <3>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call maintained in the handset
- Incoming call connected to the loudspeaker
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated 2h
Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 111/117
Step Procedure Result / Effect
2j VGC 20X call to CR-A (eMLPP <3>)
- Ongoing call maintained in the handset
- Incoming call connected to the loudspeaker 2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
- Ongoing call maintained
- Incoming call indicated 2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
2p Shunting Emergency call to CR-A
(eMLPP <0>) - Ongoing call maintained in the handset
- Incoming call connected to the loudspeaker 2q SGC 500 call to CR-A (eMLPP <3>)
2r SGC 50X call to CR-A (eMLPP <3>)
5.1.3 Call arbitration – ongoing public address call (over radio link)
Purpose: This test is to show the call arbitration with an ongoing public address call over radio link.
Precondition: Cab Radio test configuration; MS-A is in an ongoing call with CR-A’s Public Address
over radio link (eMLPP<3>);
References:
EIRENE SRS:
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>)
- Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>)
1f ”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>)
1i Call to the Intercom from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call connected to Intercom
1j Call to the Chief Conductor from CR-A
(over radio link) Not possible
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
1l VGC 20X call from CR-A (eMLPP <3>) - Ongoing call maintained
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 112/117
Step Procedure Result / Effect
1m VBC call from CR-A (eMLPP <3>) - New call not established
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f
”Other drivers same train” call to CR-A
This test is only applicable if CR-A allows
a non-leading driver to register FC08.
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
- Ongoing call maintained
- Incoming call rejected 2h
Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link)
2j VGC 20X call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
5.2 Intercom
5.2.1 Intercom system - incoming call
Purpose: This test is to show that the Cab Radio can receive and join an incoming call and
terminate communication involving the Cab Radio’s Intercom system.
Precondition: Cab Radio test configuration. Intercom has a registered FN
References:
EIRENE FRS :
EIRENE SRS :
§ 5.2.2.71, 5.2.2.73, 5.2.2.74
§ 5.6.1
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 113/117
Step Procedure Result / Effect
1
(MS-A is in an ongoing call with
CR-A’s Intercom, eMLPP <4>)
- none -
- Indication is given to the driver that CR-A is
busy
- MS-A can be heard on the Intercom
2 CR-A picks up handset Driver of CR-A joins the communication
3 CR-A initiates another call
- Communication between MS-A and Intercom
terminated
- New call initiated
5.2.2 Call arbitration – ongoing intercom call
Purpose: This test is to show that the call arbitration with an ongoing intercom call using UIC
intercom link.
Precondition: Cab Radio test configuration; CR-A is in an ongoing call with its Intercom using UIC
intercom link;
References:
EIRENE SRS:
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>)
- Ongoing call terminated
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>) Not possible
1i Call to the Intercom from CR-A
(using UIC intercom link) No change
1j Call to the Chief Conductor from CR-A
(over radio link)
- Ongoing call terminated
- New call established
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call terminated
- New call established
1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
1p VBC call from CR-A (eMLPP <4>)
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 114/117
Step Procedure Result / Effect
1q PtP call from CR-A (eMLPP <4>)
1r Shunting Emergency call from CR-A
(eMLPP <0>)
1s SGC 500 call from CR-A (eMLPP <3>)
1t SGC 50X call from CR-A (eMLPP <3>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call maintained in the handset
- Incoming call connected to the loudspeaker
2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
2e Call from Controller to CR-A (eMLPP
<3>)
2f ”Other drivers same train” call to CR-A
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>) - Ongoing call maintained
- Incoming call indicated 2h
Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
2i Call to CR-A from the Intercom
(using UIC intercom link) Not possible
2j VGC 20X call to CR-A (eMLPP <3>)
- Ongoing call maintained in the handset
- Incoming call connected to the loudspeaker 2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
- Ongoing call maintained
- Incoming call indicated 2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
2p Shunting Emergency call to CR-A
(eMLPP <0>) - Ongoing call maintained in the handset
- Incoming call connected to the loudspeaker 2q SGC 500 call to CR-A (eMLPP <3>)
2r SGC 50X call to CR-A (eMLPP <3>)
5.2.3 Call arbitration – ongoing intercom call (over radio link)
Purpose: This test is to show that the call arbitration with an ongoing intercom call over radio link.
Precondition: Cab Radio test configuration; CR-A’s Intercom is in an ongoing call with Contorller
over radio link (eMLPP<3>);
References:
EIRENE SRS :
§ 5.5.20, 5.5.21, 5A.1.1, 5A.1.2
Step Procedure Result / Effect
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 115/117
Step Procedure Result / Effect
New outgoing calls
1a Emergency call from CR-A (eMLPP
<0>) - Ongoing call terminated
- New call established 1b PtP call from CR-A (eMLPP <2>)
1c VGC 200 call from CR-A (eMLPP <2>)
1d VGC 555 call from CR-A (eMLPP <3>) - Ongoing call maintained
- New call not established
1e Call to Controller from CR-A (eMLPP
<3>) - Ongoing call terminated
- New call established 1f
”Other drivers same train” call from
CR-A
1g Call to the Public Address from CR-A
(using UIC intercom link)
Preferred Implementation:
- Ongoing call maintained
- Public Address connected
Optional Implementation:
- Ongoing call terminated
- Public Address connected
1h Call to Controller from CR-A’s Intercom
(over radio link, eMLPP <3>) Not possible
1i Call to the Intercom from CR-A
(using UIC intercom link) No change
1j Call to the Chief Conductor from CR-A
(over radio link) Not possible
1k Call to the Chief Conductor from CR-A
(using UIC intercom link)
- Ongoing call maintained
- New call sent on Public Address
1l VGC 20X call from CR-A (eMLPP <3>)
- Ongoing call terminated
- New call established 1m VBC call from CR-A (eMLPP <3>)
1n PtP call from CR-A (eMLPP <3>)
1o VGC 20X call from CR-A (eMLPP <4>)
- Ongoing call maintained
- New call not established 1p VBC call from CR-A (eMLPP <4>)
1q PtP call from CR-A (eMLPP <4>)
New incoming calls
2a Emergency call to CR-A (eMLPP <0>)
- Ongoing call terminated
- Incoming call connected 2b PtP call to CR-A (eMLPP <2>)
2c VGC 200 call to CR-A (eMLPP <2>)
2d VGC 555 call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2e Call from Controller to CR-A (eMLPP
<3>)
2f
”Other drivers same train” call to CR-A
This test is only applicable if CR-A allows
a non-leading driver to register FC07.
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 116/117
Step Procedure Result / Effect
2g Call to CR-A’s Public Address
(over radio link, eMLPP <3>)
2h Call to CR-A’s Intercom
(over radio link, eMLPP <3>)
- Ongoing call maintained
- Incoming call rejected
2i Call to CR-A from the Intercom
(using UIC intercom link) Not possible
2j VGC 20X call to CR-A (eMLPP <3>)
- Ongoing call maintained
- Incoming call indicated
2k VBC call to CR-A (eMLPP <3>)
2l PtP call to CR-A (eMLPP <3>)
2m VGC 20X call to CR-A (eMLPP <4>)
2n VBC call to CR-A (eMLPP <4>)
2o PtP call to CR-A (eMLPP <4>)
5.3 Train-borne recorder
Purpose: This test is to show that the Cab Radio records the details of the call confirmation in the
train-borne recorder.
Precondition: Cab Radio test configuration. CR-A has a train borne recorder connected via Train
Interface Unit or directly by means of a nationally determined interface.
References:
EIRENE SRS :
§ 13.5.8
Step Procedure Result / Effect
1 CR-A initiates emergency call Call established, communication possible
2 CR-A terminates emergency call Call terminated
3
- none –
(CR-A starts call confirmation
in the background)
- Call confirmation finished
- Details of the call confirmation stored in the
train-borne recorded:
Entry #1:
- PL_CALL (Priority of confirmed call)
- GC_REF (Group Call Reference)
- FNR (Functional Number)
Entry#2:
- T_DUR (Duration of call)
- CAUSE (Reason for termination)
Entry #3:
- ACK/CAUSE (Value of the final acknowledge)
- N_ACK (Number of retries)
5.4 Bulk registration / deregistration
Purpose: This test is to show that it is possible to register up to ten Functional Numbers to items of
equipment physically connected to the Cab Radio using bulk registration within 30
Test specifications for GSM-R MI related requirements Part 1: Cab Radio
Doc.-N°: O-3001-1 v 1.0.0 117/117
seconds and later it can be also deregistered within 30 seconds using bulk deregistration.
Note: If the network has basic bulk registration capabilities registrations are performed for all
function codes which were requested by the Cab Radio. Otherwise if the network has
enhanced bulk registration capabilities it may override the request and registers predefined
function codes for the Cab Radio. “SI” is the International EIRENE Number with Function
Code 01. “FC_LIST” is a list of two-digit function codes starting with a space character
(0x20) to be registered to the Cab Radio in addition to Function Code 01.
Precondition:
Cab Radio test configuration. Cab Radio has no FN registered on the network. Both the
network and the Cab Radio has bulk registration / deregistration capabilities.
References:
EIRENE FRS :
§ 11.3.2.3, 11.3.3.3
Step Procedure Result / Effect
1
CR-A starts bulk registration procedure
for
10 different Functional Numbers
(using the MMI or by external device)
- Registration started using only one UUSD
message containing:
* * 214 * SI * * * BULK9 FC_LIST #
(optionally * * 214 * SI * * * BULK0 # can be
used when network has enhanced bulk
registration capabilities and override the
registration request with the same amount of
Function Codes)
- Registration finished within 30 seconds
2
- none -
(MS-A initiates a call to all registered
Function Codes of CR-A)
Call established, communication possible
3 - none -
(initiator terminates the call) Call terminated
4
CR-A starts bulk deregistration
procedure for the previously registered10
Functional Numbers
(using the MMI or by external device)
- Deregistration started using only one UUSD
message containing:
# # 214 * SI * * * BULK9 FC_LIST # - Deregistration finished within 30 seconds
5
- none -
(MS-A initiates a call to the previously
registered10 Functional Numbers of CR-
A)
Call cannot be established