8/8/2019 Sustainability It
1/14
GEEN IT ENVIRONMENTFOR BOX HILL INSTITUTE
CHANDANA EDIRISINGHE
0799607
8/8/2019 Sustainability It
2/14
INTRODUCTION
Boxhill Institute is an one of the most popular educationprovider which is based in Melbourne.
This institute has many LAB and lecture rooms andthey consists of computing, electronic and electricalequipments.
The main focus of this presentation is to provide informationabout how to make better sustainable IT environment forBoxhill Institute.
8/8/2019 Sustainability It
3/14
OBJECTIVES
This energy audit project mainly focus on 6 LAB rooms whichconsists of more ICT equipments.
Identifies the main energy consumption areas
Identifies drawback of current process
Introduce power management policies
The end result of this project is introducing what is ICTsustainability and implementing Greener ICT environment.
8/8/2019 Sustainability It
4/14
IT and Energy Assets
The institute uses following IT and energy assetsfor their activities.
Desktop Computers with LCDMonitors
Network switches and routers
Multimedia Projectors
Fluorescent Lamps
Compact Fluorescent Lamps (CFL)
Printers
Multimedia Speakers
8/8/2019 Sustainability It
5/14
IT and Energy Assets
Comments
Room:N
151
Quantity:
Dimensions:
Orientation:
WallColor:
White
EntryPoints:
1
Legend
C Computers
P1 - Printer
P2 Projectors
L - Lightning
8/8/2019 Sustainability It
6/14
Current energy usage
No Qty ItemRatin
g Hours Days Kwh/DayKwh/Per
YearC1 24 Acer PC On 70 8 5 9.600 3504.00
C1 24Acer PC-
Standby 7 16 24 3.218 1174.57
C1 24 Monitor On 28 8 5 3.840 1401.60
C1 24Monitor
Standby 3 5 2 0.402 146.73L1 16 2 x FT 72 8 5 6.583 2402.74
P1 1HP Laser
Printer SB 11 4 5 0.031 11.47P2 1 Projector 250 3 5 0.536 195.54Sw 8 Switch 32 4 5 0.091 33.37Rt 10 Routers 37 4 5 1.057 385.86 25.359 9255.88
Sample Data from Room 151
8/8/2019 Sustainability It
7/14
Current energy usage
Total energy usage of 6 LAB
Rooms
No Qty ItemRatin
gHour
s DaysTotKwh Per Year
C1 124 PC On 63.040 23009.60
C1 124 PC-Standby 7.488 2733.12C1 124 Monitor On 23.936 8736.64
C1 124MonitorStandby 5.952 2172.48
L1 82 2 x FT 55.872 20393.28P2 5 Projector 5.720 2087.80
Sw 42 Switch 5.704 2081.96Rt 49 Routers 5.112 1865.88
172.82
4 63080.76
8/8/2019 Sustainability It
8/14
Current energy profile
0
2
4
6
8
10
12
8/8/2019 Sustainability It
9/14
CURRENT DRAWBACKS
PCs and Monitors has long stand by time. Monitors used higher brightness.
Fluorescent Lamps are switched ON most of time.
Lack of using Compact Fluorescent Lamps(CFL)
8/8/2019 Sustainability It
10/14
FUTURE CHANGES
Switched off PCs and monitors when they are not in use
Adjust monitors for low brightness
Replacing inefficient LCD monitors with high efficient, low
power consuming monitors (LED)
Switched off all the laps when theres no classes. (Use
censers, timers)
Introduced power management polices for computing
environment
Install CFL lamps for each and every LAB room.
8/8/2019 Sustainability It
11/14
No Qty ItemRatin
gHours Days
TotKWh
PerYear
KWh
C1 24 Acer PC On 70 8 5 9.600 3504.00 Save1147.57
C1 24 Acer PC-Standby 0 0 0 0.000 0.00
C1 24 Monitor On 28 8 5 3.840 1401.60Save
146.73C1 24 Monitor Standby 0 0 0 0.000 0.00
L1 16 CFL 14 8 5 1.280 467.20Save
1935.54
P1 1 HP Laser Printer SB 11 4 5 0.031 11.47
P2 1 Projector 250 3 5 0.536 195.54
Sw 8 Switch 32 4 5 0.091 33.37
Rt 10 Routers 37 4 5 1.057 385.86
16.436 5999.043229.84
Projected Energy Usage
Sample Data from Room 151
8/8/2019 Sustainability It
12/14
0
2
4
6
8
10
12
Projected Energy Profile
8/8/2019 Sustainability It
13/14
Projected Energy Profile
0
2
4
6
8
10
12
8/8/2019 Sustainability It
14/14
THE END