EMROL – Your power partner
EMROL – Your power partner
Support – Part twoSupport – Part two What are profiles and an explanation of the
parameters How to improve the accuracy of a capacity test Charger and cycle test on a battery Use of monitor test The possibility of recording data in a system with a
load/source on a battery Can the AlfaBat break down, how can you test it
(tools and technical manual) and how can you fix it (spare parts + instructions)
EMROL – Your power partner
ProfilesProfiles What are profiles? What are parameters?
3 profiles in the AlfaBat, Unlimited on the PC
How to use them?
Always use the same profile or choose to select one
Upload to device
EMROL – Your power partner
Profile ParametersProfile ParametersParameter Min Max Default
01: Battery voltage autodetection ( 0 = Manual / 1 = Auto ) 0 1 102: Preselect battery voltage ( 00 = 6V / 01 = 8V / 11 = 12V ) 00 11 1103: Use Preset mode ( 0 = Automatic / 1 = Manual ) 0 1 104: Preset Mode ( 00 = discharge, 01 = charger test, 10 = cycle, 11 = record ) 00 11 0005: Record Voltage ( 0 = OFF, 1 = ON ) 0 1 106: Record Current ( 0 = OFF, 1 = ON ) 0 1 007: Printer output enable ( 0 = OFF, 1 = ON ) 0 1 008: Preset Capacity ( 0 = Manual, 0.8 - 100 Ah ) 0.8 100 20.0009: Capacity Unit ( 0 = Manual, 5 = C5, 10 = C10, 20 = C20 ) 5 20 010: Peukert Factor ( 0 = Manual, 1.10, 1.12, 1.14, .., 1.36 ) 1.10 1.36 1.2011: Peukert calculation test ( 0 = OFF / 1 = ON ) 0 1 012: Temperature ( 0 = Manual, 1 .. 127) 0 127 013: Temperature Unit ( 0 = °C, 1 = °F) 0 1 014: Maximum Charging Time / Recording Time ( 0 = Manual, 1 .. 99 hour ) 0 99 1215: Number of cycle in cycle mode ( 0 = Manual, 255 = Unlimited, 1 .. 254 ) 0 255 316: Offset (1/impedance) 0 255 2417: Bad Cell Timer in minutes ( 0 = Auto, 1..30 ) 0 30 018: Bad Cell Voltage High level ( 0 = Auto, 1.50V .. 2.55V ) 1.50 2.55 0.0019: Bad Cell Voltage Low level ( 0 = Auto, 1.50V .. 2.55V ) 1.50 2.55 0.0020: End of discharge voltage in Volt / element ( 0 = Auto, 1.51 .. 2.55 ) 1.51 2.55 0.0021: Needs charging voltage in Volt / element ( 0 = Auto, 1.51 .. 2.55 ) 1.51 2.55 0.0022: Pass / Fail Treshold in % ( 0 .. 100 ) 0 100 6023: Maximum discharge in % ( 0 = OFF / 1 .. 150 ) 0 150 024: Discharge current ( 0 = AUTO, 5 = 5A, 10 = 10A) 0.00 10.00 0.00
EMROL – Your power partner
ImprovImprovinging the accuracy the accuracy Correct battery temperature
Battery quality Peukert value
EMROL – Your power partner
PeukertPeukert Peukert capacity = capacity when discharged
with one ampere
Normal value = 1.10 to 1.36
Ideal value = 1
High values indicate poor battery quality
AlfaBat has a function to determine this factor
EMROL – Your power partner
Charger and cycle test Charger and cycle test on a batteryon a battery
Select a correct profile Adaptor is required Connect the charger
Charger test: result in Ah Usefull to record a charger’s regime.
Cycle discharge: result in % Cycle charge: Charge factor
EMROL – Your power partner
Charge FactorCharge Factor Relation between the discharged capacity and
the charged capacity
> 1.10 : to compensate charge losses you need to put more energy in a battery then what was extracted.
EMROL – Your power partner
Monitor TestMonitor Test Online tracking of a test in progress
Necessary during cycle test (unless printer is used)
Needed for peukert calculation
Alternative to cycle test with PC: use of the printer
EMROL – Your power partner
Cycle test exampleCycle test example
EMROL – Your power partner
Recording data in a Recording data in a systemsystem
Connect the source/load to the charger port. Make sure the load respects the max current 15A or 50A.
Connect the battery to the battery port
Start a recording test (use the correct profile)
EMROL – Your power partner
Technical solutionsTechnical solutions1. Simple things first: all connections are present,
polarity ok, bad connection, latest firmware / software, ...
2. Look in the knowledge base on the Emrol website.
3. If you are sure there is a technical problem look in the technical manual
4. Use the service tools to locate / fix the technical problem
EMROL – Your power partner
Technical Technical ManualManual Use ONLY original spare parts (FAN, Fuse,
controller board, ...).
Use one of the tools for testing the device in combination with the Windows software.
EMROL – Your power partner
AlfaBat ServiceAlfaBat ServiceProgrammingProgramming
EMROL – Your power partner
AlfaBat ServiceAlfaBat ServicePower supplyPower supply
EMROL – Your power partner
AlfaBat ServiceAlfaBat ServiceMeasuringMeasuring
EMROL – Your power partner
AlfaBat ServiceAlfaBat ServiceTest PeripheralTest Peripheral
EMROL – Your power partner
AlfaBat ServiceAlfaBat ServiceDeviceDevice
EMROL – Your power partner
Thank you