Port systems› T-Port™ HP› T-Port™ Low Profile HP› Tita Jet™ Light II HP› Tita Jet™ II Low Profile HP› Jet Port® Plus II HP› Dual Port HP
The implantable port systems ofpfm medical meet the high demands of users and patients: safety, quality and selection from a broad portfolio.
www.pfmmedicalusa.com
Features and Benefits
L100
4/A
www.pfmmedicalusa.com
© PFM Medical Inc. 2015, All Rights Reserved.
pfm medical, inc.1815 Aston Ave., Ste. 106 • Carlsbad, CA 92008Ph: 760.758.8749 • Fx: [email protected] • www.pfmmedicalusa.com
Radiopaque CT Markings printed on bottom surface for visibility under x-ray.
Hybrid DesignCombines light weight plastic with durable titanium
Strong titanium reservoirReliability, dependable and durability
Plastic outer bodyMinimizes discomfortby light weight form
Highly compressed siliconeSecures and closes
Port systems
High Pressure Port systems
View
Knowledge
▸ ▸ ▸ ▸ ▸ ▸ ▸
▸
▸ ▸ ▸
▸ ▸ ▸ ▸ ▸ ▸ ▸
▸
Configurations
▸
▸
▸
▸
▸
▸
▸▸
Details
The implantable port systems of pfm medical meet the high demands of users and patients: safety, quality, and selection from a broad portfolio.
The High Pressure Port systems from pfm medical represent the latest development in the field of implantable port systems. These systems allow, besides the application of common substances for chemotherapy and parenteral nutrition, the high pressure application of contrast mediums during a follow-up examination of the tumor within the
framework of staging for examinations in computed tomog-raphy. The well-known and proven advantages of implant-able port systems are thereby enriched with another diagnostic capability. These offer users and patients a high level of comfort and safety and set new standards.
High pressure-resistant catheter made of biostable, implantation-tested polyurethane (PU)Radiopaque catheterVessel-friendly, atraumatic catheter tipAttachable or preconnected cathetersHighly compressed silicone membrane for secure closingof septum and secure holding of puncturing needleEasy to palpate septum for safe identification of thepuncture siteLatex-, DEHP- and PVC-freeOpen or silicone filled (SP) suture holes
The required flow rate and pressure stability (during injec-tion of contrast medium for CT examination) can be guaran-
teed with the 19 G (1.1 mm) Huber needle of the JetCan™series. Both product ranges are available from pfm medical.
Pressure test conditions: High pressure injector with set max. pressure of 21 bar/300 psi; flow rate ml/s; connection tube 1,5 m 60 sec.; contrast medium Visipaque® 320 at a temperature of 37 to 38 °C; with vascular simulation; Huber needle
JetCan™ (19 G, 25 mm) with extension. Instructions for use and port care advice must be strictly adhered to. Data from in-vitro test series is available on request.
Set components 1 Port with CT marking 1 Catheter with atraumatic tip 2 Click-connectors 1 Rinsing needle 1 JetCan™ straight Huber needle (22 G, 25 mm) 1 Vein lifter Accessories for identification of high pressure port (purple bracelet, patient ID-card, pendant for key ring) 1 Introducer kit (peel-away-sheath with dilator, guide wire 70 cm with J-tip, puncture needle) 1 Tunneling needle 1 Patient ID-card 1 Syringe (10 ml); 2 Syringes with DualPort
Basic components 1 Port with CT marking 1 Catheter with atraumatic tip 2 Click-connectors 1 Rinsing needle 1 JetCan™ straight Huber needle (22 G, 25 mm) 1 Vein lifter Accessories for identification of high pressure port (purple bracelet, patient ID-card, pendant for key ring) 1 Patient ID-card
Port systems
High Pressure Port Comparison
T-Port™
MRI Compatible (to 3-Tesla)
High Pressure Rated to 300 psi
Radiopaque CT Markings
Titanium Design
Plastic Design
Hybrid Design(plastic body and titanium reservior)
Open Suture Holes
Silicone Filled Suture Holes
Single Lumen
Dual Lumen
Polyurethane Catheter
4.8 F
6.6 F
8.0 F
9.6 F
T-Port™Low Profile
Tita Jet™Light II HP
Tita Jet™ IILow Profile HP
Jet Port®Plus II HP Dual Port HP
Port systems Port systems
The Dual Port High Pressure is an implantable double-chamber port with a port inlay made of titanium and a plastic casing for the simultaneous administration of incompatible medication. This port system also permits the high pressure application of a contrast medium as part of regular tumor assessment.
Dual Port High Pressure
View
Excellent plastic-titanium combination in Tita Jet™ LightThe special combination of two materials provides light weight and high safety.
Suitable for high-pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Ergonomic designA flat construction form for easy placement and handling.
Easy identificationPalpation of both excellently-palpable port chambers allows for their easy location.
Minimal mixingThe graduated openings of the catheter lumen ensure that mixing of applied medication is kept to a minimum.
MRT-compatibleReduced artifact formation(up to 3.0 T).
Connection mechanismThe transparent click-con-nector for simple andeasy connection as well assecure and reliable fixation ofcatheter and port chamber.
Securing the portSilicone filled suture holes.
Benefits
Detailed View Technical Data
Ordering Information
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s Length of catheter: 50 cm Dimensions: 41.0 x 26.0 x 12.7 mm (L x W x H) Weight: 9.0 g Residual volume per chamber: 0.37 ml Septum diameter: each 11.0 mm Puncture frequency (non-coring 19-G needle): 500 per chamber
Dual Port High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.021.0078-HA2 PU Attachable 2 x 1.1 mm 3.2 mm 9.6 F 2 x 22 ml/min. 2 x 0.20 ml/10cm length of catheter Yes
616.022.0078-HA3 PU Attachable 2 x 1.1 mm 3.2 mm 9.6 F 2 x 22 ml/min. 2 x 0.20 ml/10cm length of catheter Yes
The implantable port system Tita Jet™ Light Low Profile High Pressure is used to administer systemic chemotherapy, long-term parenteral nutrition or long-term medication. This port system also permits the high pressure application of a contrast medium as part of regular tumor assessment. The slim design allows for its use in pediatrics or as a peripheral port, e.g. for placement in the arm.
Tita Jet™ Light Low Profile High Pressure
View
Excellent plastic-titanium combinationThe special combination of two materials provides light weight and high safety.
Suitable for high pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Safe identificationThe radiopaque CT marking at the bottom of the port ensures identification as high pressure port.
Reduced risk of migrationThe low weight reduces the risk of migration and increases patient comfort.
Slim designThe narrow shape of the port allows for its use in pediatrics or as a peripheral port, e.g. for placement in the arm.
Shovel nose designGuides port pocket placement.
Easy placementSmall dimensions for easy placement.
MRI-compatibleReduced artifact formation (up to 3.0 T).
Connection mechanismThe transparent click-connector for easy and simple connection as well as secure and reliable fixation of catheter and port chamber.
Benefits
Technical Data
Ordering Information
Weight: 3.5 g Residual volume per chamber: 0.30 Septum diameter: 8.0 mm Puncture frequency (non-coring 19-G needle): 600
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s (3ml/s with catheter 4.8 F) Length of catheter: 75 cm Dimensions: 24.0 x 20.5 x 10.3 mm (L x W x H)
Tita Jet™ II Low Profile High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.360.9070-HA PU Attachable 1.0 mm 1.6 mm 4.8 F 14 ml/min. 0.10 ml/10 cm length of catheter No
616.360.8070-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 25 ml/min. 0.18 ml/10 cm length of catheter No
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle2. Jet Port® Dual High Pressure3. Tita Jet™Light Dual High Pressure
Port systems Port systems
The Dual Port High Pressure is an implantable double-chamber port with a port inlay made of titanium and a plastic casing for the simultaneous administration of incompatible medication. This port system also permits the high pressure application of a contrast medium as part of regular tumor assessment.
Dual Port High Pressure
View
Excellent plastic-titanium combination in Tita Jet™ LightThe special combination of two materials provides light weight and high safety.
Suitable for high-pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Ergonomic designA flat construction form for easy placement and handling.
Easy identificationPalpation of both excellently-palpable port chambers allows for their easy location.
Minimal mixingThe graduated openings of the catheter lumen ensure that mixing of applied medication is kept to a minimum.
MRT-compatibleReduced artifact formation(up to 3.0 T).
Connection mechanismThe transparent click-con-nector for simple andeasy connection as well assecure and reliable fixation ofcatheter and port chamber.
Securing the portSilicone filled suture holes.
Benefits
Detailed View Technical Data
Ordering Information
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s Length of catheter: 50 cm Dimensions: 41.0 x 26.0 x 12.7 mm (L x W x H) Weight: 9.0 g Residual volume per chamber: 0.37 ml Septum diameter: each 11.0 mm Puncture frequency (non-coring 19-G needle): 500 per chamber
Dual Port High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.021.0078-HA2 PU Attachable 2 x 1.1 mm 3.2 mm 9.6 F 2 x 22 ml/min. 2 x 0.20 ml/10cm length of catheter Yes
616.022.0078-HA3 PU Attachable 2 x 1.1 mm 3.2 mm 9.6 F 2 x 22 ml/min. 2 x 0.20 ml/10cm length of catheter Yes
The implantable port system Tita Jet™ Light Low Profile High Pressure is used to administer systemic chemotherapy, long-term parenteral nutrition or long-term medication. This port system also permits the high pressure application of a contrast medium as part of regular tumor assessment. The slim design allows for its use in pediatrics or as a peripheral port, e.g. for placement in the arm.
Tita Jet™ Light Low Profile High Pressure
View
Excellent plastic-titanium combinationThe special combination of two materials provides light weight and high safety.
Suitable for high pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Safe identificationThe radiopaque CT marking at the bottom of the port ensures identification as high pressure port.
Reduced risk of migrationThe low weight reduces the risk of migration and increases patient comfort.
Slim designThe narrow shape of the port allows for its use in pediatrics or as a peripheral port, e.g. for placement in the arm.
Shovel nose designGuides port pocket placement.
Easy placementSmall dimensions for easy placement.
MRI-compatibleReduced artifact formation (up to 3.0 T).
Connection mechanismThe transparent click-connector for easy and simple connection as well as secure and reliable fixation of catheter and port chamber.
Benefits
Technical Data
Ordering Information
Weight: 3.5 g Residual volume per chamber: 0.30 Septum diameter: 8.0 mm Puncture frequency (non-coring 19-G needle): 600
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s (3ml/s with catheter 4.8 F) Length of catheter: 75 cm Dimensions: 24.0 x 20.5 x 10.3 mm (L x W x H)
Tita Jet™ II Low Profile High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.360.9070-HA PU Attachable 1.0 mm 1.6 mm 4.8 F 14 ml/min. 0.10 ml/10 cm length of catheter No
616.360.8070-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 25 ml/min. 0.18 ml/10 cm length of catheter No
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle2. Jet Port® Dual High Pressure3. Tita Jet™Light Dual High Pressure
Port systems Port systems
The implantable port system T-Port High Pressure and T-Port Low Profile High Pressure made of titanium are used to administer systemic chemotherapy, long-term parenteral nutrition or long-term medication. This port system also permits the high pressure application of contrast mediums as part of regular tumor staging.
T-Port High Pressure and T-Port Low Profile High Pressure
View
Titanium material ofproven qualityThe excellent material ensures a highly reliable usage.
Suitable for high pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Safe identificationThe radiopaque CT markingat the bottom of the port ensures identification as ahigh pressure port.
Small dimensions with T-Port Low Profile High PressureSmall version for more discreet placing of the port.
Connection mechanismTransparent click-connector for simple and easy connection as well as secure and reliable fixation of catheter and port chamber.
Benefits
Technical Data
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s Length of catheter: 75 cm T-Port High Pressure: Dimensions: 27.0 mm (Ø base plate) x 13.0 mm (height) Weight: 14.5 g Residual volume chamber: 0.7 ml Septum diameter: 12.0 mm Puncture frequency (non-coring 19-G needle): 1,000
▸ ▸▸ ▸ ▸
T-Port Low Profile High Pressure: Dimensions: 23.0 mm (Ø base plate) x 10.0 mm (height) Weight: 8.0 g Residual volume chamber: 0.2 ml Septum diameter: 9.0 mm Puncture frequency (non-coring 19-G needle): 600
▸ ▸▸ ▸ ▸
Ordering Information
The implantable port system Tita Jet™ Light II High Pressure and Jet Port® Plus II High Pressure are used to administer systemic chemotherapy, long-term parenteral nutrition or long-term medication. This port system also permits the high pressure application of a contrast medium as part of regular tumor staging.
Tita Jet™ Light II High Pressure and Jet Port® Plus II High Pressure
View
Tita Jet™ Light II High PressureExcellent plastic-titanium combination.
Jet Port® Plus II High PressureHigh-quality plastic (poly-oxymethylene).
Suitable for high pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Safe identificationThe radiopaque CT marking at the bottom of the port guarantees the identification as a high pressure port.
Reduced risk of migrationThe low weight reduces the risk of migration and increases patient comfort.
Easy placementThe oval shape of the port makes it easy to insert the port into the prepared pocket.
MRI-compatibleReduced artifact formation (up to 3.0 T).
Connection mechanismThe transparent click-connector provides a simple and easy connection as well as secure and reliable fixation of the catheter and port chamber.
Benefits
Technical Data
Ordering Information
Weight Jet Port® Plus II High Pressure: 6.6 g Residual volume chamber: 0.37 ml Septum diameter: 12.1 mm Puncture frequency (non-coring 19-G needle): 1,000
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s Length of catheter: 75 cm Dimensions: 32.1 x 23.6 x 13.2 mm (L x W x H) Weight TitaJet™ light II High Pressure: 6.9 g
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle
Tita Jet™ Light II High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.368.3077-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter No
616.368.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
Jet Port Plus II High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.367.3077-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter No
616.367.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle
T-Port High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.365.3078-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter Yes
616.365.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
616.365.2088-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter Yes
T-Port Low Profile High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.366.3077-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter No
616.366.3078-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter Yes
616.366.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
616.366.2088-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter Yes
Port systems Port systems
The implantable port system T-Port High Pressure and T-Port Low Profile High Pressure made of titanium are used to administer systemic chemotherapy, long-term parenteral nutrition or long-term medication. This port system also permits the high pressure application of contrast mediums as part of regular tumor staging.
T-Port High Pressure and T-Port Low Profile High Pressure
View
Titanium material ofproven qualityThe excellent material ensures a highly reliable usage.
Suitable for high pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Safe identificationThe radiopaque CT markingat the bottom of the port ensures identification as ahigh pressure port.
Small dimensions with T-Port Low Profile High PressureSmall version for more discreet placing of the port.
Connection mechanismTransparent click-connector for simple and easy connection as well as secure and reliable fixation of catheter and port chamber.
Benefits
Technical Data
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s Length of catheter: 75 cm T-Port High Pressure: Dimensions: 27.0 mm (Ø base plate) x 13.0 mm (height) Weight: 14.5 g Residual volume chamber: 0.7 ml Septum diameter: 12.0 mm Puncture frequency (non-coring 19-G needle): 1,000
▸ ▸▸ ▸ ▸
T-Port Low Profile High Pressure: Dimensions: 23.0 mm (Ø base plate) x 10.0 mm (height) Weight: 8.0 g Residual volume chamber: 0.2 ml Septum diameter: 9.0 mm Puncture frequency (non-coring 19-G needle): 600
▸ ▸▸ ▸ ▸
Ordering Information
The implantable port system Tita Jet™ Light II High Pressure and Jet Port® Plus II High Pressure are used to administer systemic chemotherapy, long-term parenteral nutrition or long-term medication. This port system also permits the high pressure application of a contrast medium as part of regular tumor staging.
Tita Jet™ Light II High Pressure and Jet Port® Plus II High Pressure
View
Tita Jet™ Light II High PressureExcellent plastic-titanium combination.
Jet Port® Plus II High PressureHigh-quality plastic (poly-oxymethylene).
Suitable for high pressure applicationsThe pressure resistance of the systems allows for use of power injectors.
Safe identificationThe radiopaque CT marking at the bottom of the port guarantees the identification as a high pressure port.
Reduced risk of migrationThe low weight reduces the risk of migration and increases patient comfort.
Easy placementThe oval shape of the port makes it easy to insert the port into the prepared pocket.
MRI-compatibleReduced artifact formation (up to 3.0 T).
Connection mechanismThe transparent click-connector provides a simple and easy connection as well as secure and reliable fixation of the catheter and port chamber.
Benefits
Technical Data
Ordering Information
Weight Jet Port® Plus II High Pressure: 6.6 g Residual volume chamber: 0.37 ml Septum diameter: 12.1 mm Puncture frequency (non-coring 19-G needle): 1,000
Pressure stability: up to max. 300 psi with maximum flow rate of 5 ml/s Length of catheter: 75 cm Dimensions: 32.1 x 23.6 x 13.2 mm (L x W x H) Weight TitaJet™ light II High Pressure: 6.9 g
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle
Tita Jet™ Light II High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.368.3077-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter No
616.368.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
Jet Port Plus II High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.367.3077-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter No
616.367.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
1. Flow Rate: 0.9% saline, gravity, 100 cm height, 40 cm catheter length, 19G non-coring needle
T-Port High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.365.3078-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter Yes
616.365.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
616.365.2088-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter Yes
T-Port Low Profile High Pressure
REF Catheter ID OD OD Flow rate1 Residual volume SP
616.366.3077-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter No
616.366.3078-HA PU Attachable 1.3 mm 2.2 mm 6.6 F 30 ml/min. 0.18 ml/10 cm length of catheter Yes
616.366.2087-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter No
616.366.2088-HA PU Attachable 1.6 mm 2.6 mm 8.0 F 35 ml/min. 0.23 ml/10 cm length of catheter Yes
Port systems
High Pressure Port systems
View
Knowledge
▸ ▸ ▸ ▸ ▸ ▸ ▸
▸
▸ ▸ ▸
▸ ▸ ▸ ▸ ▸ ▸ ▸
▸
Configurations
▸
▸
▸
▸
▸
▸
▸▸
Details
The implantable port systems of pfm medical meet the high demands of users and patients: safety, quality, and selection from a broad portfolio.
The High Pressure Port systems from pfm medical represent the latest development in the field of implantable port systems. These systems allow, besides the application of common substances for chemotherapy and parenteral nutrition, the high pressure application of contrast mediums during a follow-up examination of the tumor within the
framework of staging for examinations in computed tomog-raphy. The well-known and proven advantages of implant-able port systems are thereby enriched with another diagnostic capability. These offer users and patients a high level of comfort and safety and set new standards.
High pressure-resistant catheter made of biostable, implantation-tested polyurethane (PU)Radiopaque catheterVessel-friendly, atraumatic catheter tipAttachable or preconnected cathetersHighly compressed silicone membrane for secure closingof septum and secure holding of puncturing needleEasy to palpate septum for safe identification of thepuncture siteLatex-, DEHP- and PVC-freeOpen or silicone filled (SP) suture holes
The required flow rate and pressure stability (during injec-tion of contrast medium for CT examination) can be guaran-
teed with the 19 G (1.1 mm) Huber needle of the JetCan™series. Both product ranges are available from pfm medical.
Pressure test conditions: High pressure injector with set max. pressure of 21 bar/300 psi; flow rate ml/s; connection tube 1,5 m 60 sec.; contrast medium Visipaque® 320 at a temperature of 37 to 38 °C; with vascular simulation; Huber needle
JetCan™ (19 G, 25 mm) with extension. Instructions for use and port care advice must be strictly adhered to. Data from in-vitro test series is available on request.
Set components 1 Port with CT marking 1 Catheter with atraumatic tip 2 Click-connectors 1 Rinsing needle 1 JetCan™ straight Huber needle (22 G, 25 mm) 1 Vein lifter Accessories for identification of high pressure port (purple bracelet, patient ID-card, pendant for key ring) 1 Introducer kit (peel-away-sheath with dilator, guide wire 70 cm with J-tip, puncture needle) 1 Tunneling needle 1 Patient ID-card 1 Syringe (10 ml); 2 Syringes with DualPort
Basic components 1 Port with CT marking 1 Catheter with atraumatic tip 2 Click-connectors 1 Rinsing needle 1 JetCan™ straight Huber needle (22 G, 25 mm) 1 Vein lifter Accessories for identification of high pressure port (purple bracelet, patient ID-card, pendant for key ring) 1 Patient ID-card
Port systems
High Pressure Port Comparison
T-Port™
MRI Compatible (to 3-Tesla)
High Pressure Rated to 300 psi
Radiopaque CT Markings
Titanium Design
Plastic Design
Hybrid Design(plastic body and titanium reservior)
Open Suture Holes
Silicone Filled Suture Holes
Single Lumen
Dual Lumen
Polyurethane Catheter
4.8 F
6.6 F
8.0 F
9.6 F
T-Port™Low Profile
Tita Jet™Light II HP
Tita Jet™ IILow Profile HP
Jet Port®Plus II HP Dual Port HP
Port systems› T-Port™ HP› T-Port™ Low Profile HP› Tita Jet™ Light II HP› Tita Jet™ II Low Profile HP› Jet Port® Plus II HP› Dual Port HP
The implantable port systems ofpfm medical meet the high demands of users and patients: safety, quality and selection from a broad portfolio.
www.pfmmedicalusa.com
Features and Benefits
L100
4/A
www.pfmmedicalusa.com
© PFM Medical Inc. 2015, All Rights Reserved.
pfm medical, inc.1815 Aston Ave., Ste. 106 • Carlsbad, CA 92008Ph: 760.758.8749 • Fx: [email protected] • www.pfmmedicalusa.com
Radiopaque CT Markings printed on bottom surface for visibility under x-ray.
Hybrid DesignCombines light weight plastic with durable titanium
Strong titanium reservoirReliability, dependable and durability
Plastic outer bodyMinimizes discomfortby light weight form
Highly compressed siliconeSecures and closes