OPTION 1:Local Connections
OPTION 2:Dial-up Connection
OPTION 3:TCP/IP Connection
SYSTEM OVERVIEW
w w w . c d v a m e r i c a s . c o m
Every Centaur edition includes a Centaur Server with an administration console, plus all these software modules:Pro-Report with Tracker: On demand, scheduled or customized reportsFrontView: Live interactive fl oor plansFrontGuard: Display real-time visual authenticationFrontCard: Create, modify, delete and print cards, include Photo-IDLocator: Monitor real-time location of each card holderWavePlayer: Play a sound on any system event
Workstation license(CS-WSLIC):Centaur supports an unlimited amount of Workstations with any Centaur Software edition. The Workstation license includes: Centaur Administration Console andall software modules.
LITECS-AC-LITE
StandardCS-AC-STD
ProfessionalCS-AC-PRO**
EnterpriseCS-AC-ENT**
Sites 1 64 64 64
Serial Ports 1 1 1 4
Dial Up - Yes Yes Yes
TCP/IP - Yes Yes Yes
Cards* 512 2,048 8,196 16,384
Controllers* 16 32 64 256
Doors* 16 128 512 2048
* Per site ** Comes with a workstation license
LCD DisplayCK-TRAK-L
(Max. 8 per CT-V900-A)
ElevatorController
CA-A480-A(Max. 8 per CT-V900-A)
RelayExpansion Module
CA-A460-P(Max. 2 per CT-V900-A)
2-DoorExpansion Module
CA-A470-A(Max. 3 per CT-V900-A)
E-BUS NETWORK MODULE CAPACITY
Input 11K Ohm
Input 22.2K Ohm
EOL1K Ohm
Optional Loop Supervision
CONTROLLER INPUTS(UP TO 16 PER CONTROLLER)
+-Power
Supply
+-
+-Power
Supply
+-
Connect directly to controller lock terminals
ELECTROMAGNETIC LOCK OPTION OR DOOR STRIKE OPTION
+
-
+
-
ALARM SOUNDER
2-DOOR CONTROLLER
CT-V900-A
R1/DO
GND
R1/D112VOUT1OUT2OUT5
GREEN
BLACK
WHITEREDYELLOW (green LED)ORANGE (red LED)BROWN (buzzer)
Blue (Clock) Not applicable with Centaur System
R2/DO
GND
R2/D112VOUT3OUT4OUT6
DO
-
D1+V (green LED)R (red LED)B (buzzer)
H (Clock) Not applicable with Centaur System
Connect earth terminal to cold water pipe
Transformer24 VAC, 75VA
50/60Hz Class 2 2 batteries (12V, 7AH) connected in series for
24V backup
+
-
+
-
Reader wiring may differ from diagram. Please consult your dealer for details.!
SERVER TO CONTROLLER COMMUNICATION
Tamper Switch N.C. Contact
To the controller serial port, up to
7.6M (25 ft)
SERIALPORT CABLE(DB9F to DB9F)
RS-485 CONVERTER
To the controller Network, up to
1220M (4000 ft)
GN
D
A+
B-
or
To ServerUSB Port
To ServerSerial Port
To ServerSerial Port
To ServerEthernet Port
To remote modemand
fi rst controller of a site
Telephone line connection
To remote TCP/IP module(CA-ETHR-A) and
fi rst controller of a site
GND
A1+
B1-To next controller
of a site.
+12V
MODULE NETWORK(E-BUS RS-485)Furthest module can be up to 1220M (4000ft) away from the CT-V900-A controller
GND
A2+
B2-
PolycarbonateProximityReaderDGLP FN WLC
Stainless SteelProximity Reader
DGLI WLC
+
-
CONTROLLER NETWORK(RS-485)
CT-V900-A
CT-V900-A2-Door Controller
P O S I T I O N
GNDTXB-
+12V
RXG
NDA+G
ND
RECEIVE
TRANSMIT
POWER
CA-A360-A
CONVERTERSETTINGS
EOL= ON
Bias High/Low JumpersA+= LowB-= Low
CONTROLLER #2SETTINGS
EOL= OFF
Bias High/Low JumpersA+= HighB-= High
CONTROLLER #1SETTINGS
EOL= OFF
Bias High/Low JumpersA+= HighB-= High
CONTROLLER #3SETTINGS
EOL= ON
Bias High/Low JumpersA+= HighB-= High
START POINTof the RS-485 controller network.(Furthest modules can be up to 1220m (4000ft) from start point)
END POINTof the RS-485 controller network
CT-V900-A #1
CT-V900-A #2
CT-V900-A2-Door Controller
CT-V900-A #3
CT-V900-A2-Door Controller
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
DEF/R
UN
9.6K/19.2K
ADD
32
ADD
16
ADD
8
ADD
4
ADD
2
ADD
1
1 2 3 4 5 6 7 8
RS-2327.6m (25ft) max.
Addressable dipswitch
Addressable dipswitch
Addressable dipswitch
Example of Jumper Settings
HIGH
HIGH
EOL
EOL
LOW
LOW
Jumper set to LOW
Jumper set to HIGH
Jumper set to EOL ON
Jumper set to EOL OFF
ON
ON
OFF
OFF
BATT
BATTJumper set to OFF
Jumper set to ON
CONTROLLERNETWORK JUMPERS
ADDRESSABLEDIPSWITCH
E-BUSNETWORK JUMPERS
CT-V900-A CUT VIEW
At the START POINT and the END POINT of the RS-485 controller network, the controllers’ EOL jumpers= ON. All controllers in between EOL= OFF
Note: If you do not use a converter, the first CT-V900-A controller will be the START POINT.
At the START POINT of the RS-485 controller network, the controllers’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Real-Time ClockLithium Battery Setting
SERVER
CONTROLLER NETWORK
JUMPER & DIPSWITCH SETTINGS
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
+
SP
+12V
R1/
KP
DR
1/K
PC
R1/
KP
BR
1/K
PAO
UT2
OU
T1R
1/D
1R
1/D
0R
1/0V
R1/
+5V
SP
+12V
R2/
KP
DR
2/K
PC
R2/
KP
BR
2/K
PAO
UT4
OU
T3R
2/D
1R
2/D
0R
2/0V
R2/
+5V
ACAC
BAT+BAT-
V+V+V-V-
OUT5OUT6
A+B-
GNDTMPTMP
D1NCCOMD1NOD2NCCOMD2NOZ1COMZ2Z3COMZ4
CA-A470-A2-Door Expansion Module
LOCK#1
AC OK
EOLBACKUP
SWITCHADD 1SW1ADD 2SW2L1EnergizeSW3L2EnergizeSW4BACKUP1SW5BACKUP2SW6 PULSE 5&6SW7N/DSW8
READER#1DATA
READER#2DATA
NO CARD
LOW HIGH
TX RXE-BUS
B-A+
2 CARDSALL CARDSUNLOCK DOOR
20011
10101
AUX OKCOMMCHECK BATTBATT TRBL
LOCK#2
STATUS
JP120350mA/700mA
ON1 2
3 4
5 6
7 8
4
5
1
2
3
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
STATUSFREE ACCESSCOMM FAILUREBATT TROUBLE
ADDRESS 1ADDRESS 2ADDRESS 4ADDRESS 8RLY COMMSRLY OFF/ONDRM ENABLEDPWR OFF/ON
12
34
56
78
ON
NO14
NO13
NC14
NC13
COM16NC15NO15
NO16NC16
COM15
COM14
COM13
NO3
NO4
NC2
NC3
COM1
NC1
NO2
NO1
COM2
COM3
COM4
NC4
NO
7
NO
8
NC
6
NC
7
COM
5
NC
5
NO
6
NO
5
COM
6
COM
7
COM
8
NC
8
NO
11
NO
12
NC
10
NC
11
COM
9
NC
9
NO
10
NO
9
COM
10
COM
11
COM
12
NC
12
A+
GNDB-
TAMPERTAMPER
FC
+12V
AC
BAT+BAT-
AC
+12VGNDGND
FC
RL16RL1
RL2RL3
RL4
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12
RL13
RL14
RL15
DRM
MO
DULE
BATT REVERSED12V
+12V RELAYBATT
AC
EOL
BLOW HIGH
ALOW HIGH
FC OVERIDE350mA/700mA
E-BUSTXRX
Elevator ControllerCA - A480 - P
E-BUS
EOL= OFF
Bias High/LowA+= HighB-= High
EOL= OFF
Bias High/LowA+= HighB-= High
EOL= OFF
Bias High/LowA+= HighB-= High
EOL= ON
Bias High/LowA+= HighB-= High
EOL= ON
Bias High/Low JumpersA+= LowB-= Low
START POINTof the RS-485 E-bus network(Furthest module can be up to1220m (4000ft) from start point)
END POINTof the RS-485 E-bus network
CT-V900-A2-Door Controller
CT-V900-A
CA-A480-A CA-A480-A
CA-A470-A CA-A470-A
ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8ONOFF
N/D
PULSE 5&6
BACKU
P2
BACKU
P1
L2 Energize
L1 Energize
ADD
2
ADD
1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
ONOFF
PWR
OFF/O
N
DR
M EN
ABLED
RLY O
FF/ON
RLY C
OM
MS
ADD
RESS 8
ADD
RESS 4
ADD
RESS 2
ADD
RESS 1
1 2 3 4 5 6 7 8
At the START POINT and the END POINT of the installation, the modules’ EOL jumpers = ON. All modules in between EOL = OFF
At the START POINT of the network, the modules’ HIGH/LOW Bias jumpers are set to A+ = LOW and B- = LOW. All other modules’ HIGH/LOW Bias jumpers are set to A+ = HIGH and B- = HIGH
Addressabledipswitch
Addressabledipswitch
Addressabledipswitch
Addressabledipswitch
E-BUS NETWORK
JUMPER & DIPSWITCH SETTINGS
or
LAN/WAN Network
Fire alarm contact for Lock1 & Lock2
DestinationReporting Module
CA-A482-PThe DRM connects directly
to the CA-A480-A,elevator controller
TCP/IPModule
CA-ETHR-A
RS-485Network HubCA-A370-P
SOFTWARE EDITIONS
1645-A Highway 440 WestLaval, Québec, Canada, H7L3W3
Tel: (450) 682-7945, Toll Free Tel: 1-866-610-0102Fax: (450) 682-9590, Toll Free Fax: 1-866-682-9590