Congratulations! You have purchased a LUMISHORE advanced LED technology underwater lighting system. Every care has been taken to ensure your SMX-92 / SMX-152 system arrives in perfect condition, so please enjoy the ultimate experience in underwater lighting.
Please read the following pages before attempting installation to ensure complete understanding of the LUMISHORE LED lights.
• High Intensity LED light – Do not stare into the LED module at close proximity.
• The lights are high power and should be installed below the water line.
• These lights are intended to be installed on vessels no larger than 50ft (15m).
• For best underwater illumination, LUMISHORE recommends installation 4” to 12” (100-300mm) below the water line.
• Choose a location - The light must be mounted on a �at (not curved) surface. Mount on transom or side of the hull only.
• A hole will be drilled to allow the cable to be inserted; care must be taken to ensure there is unrestricted access inside the hull.
• When installing three or more lights, equal spacing 2.5’- 3’ is recommended to give a consistent light pool.
• The light is temperature sensitive and must not be located close to the exhaust outlet or other heat source.
• The SMX92 / SMX152 series operates on DC ONLY. Never connect a light to anything other than a Lumishore Smart Hub.
• The Lumishore smart hub is 10.5 to 31 volts. Never connect the hub to a voltage out of this range or AC voltage.
• The Lumishore smart hub allows each light to be individually Fused, To choose the correct fuse value for your light and
voltage supply refer to the provided fuse table in this manual.
• No chemical cleaners/chemical spray, sandblasting/pressure washing should be applied or used on lights this will
negate warranty
The EOS surface mount integrated system consists of: One or more surface mount lights, a Lumi-Hub and a control method.
Control options include a Lumi-Switch, EOS mini controller or EOS mini with built in WiFi for additional iPhone and iPad control.
Please consult with your dealer to �nd out which control option would be best for you.
The Lumi-Hub allows very simple installation of the lights with all necessary components built inside. Simply connect
the hub to the vessels DC power source, plug in the lights and your chosen method of control and the electrical installation is complete.
Follow the electrical diagrams on the following pages for a detailed guide.
1
Wiring Diagram - Switch Operation - Up to 4 Lights
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Distribution Panel
Battery
1, On/O� control2, Momentary for Mode selection
Optional Customer supplied Switch system
On/Off
Mode
Lumi-Switch - Lumishore supplied Smart Switch. On/O� and mode control in one switch
2 Core Power cablekeep as short as possible
If extended consult cablegauge guide (Page 6)
Extension cables available (see cable extension
table on page 6)
Lumi-Hub
Red & Green
Blue & Yellow
Power
Momentary
Switch Colour Code
Note: Only one master light should be installed per light system
2
Wiring Diagram - Switch Operation - Up to 8 Lights
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Distribution Panel
Battery
1, On/O� control2, Momentary for Mode selection
Optional Customer supplied Switch system
On/Off
Mode
Lumi-Switch - Lumishore supplied Smart Switch. On/O� and mode control in one switch
Lumi-Hub
Lumi-Hub
5 Core Extension cablesavailable (see cable extension
table on page 6)
3 Core extension cables available(see cable extensiontable on page 6)
Note: Twist and crimp similarcable colour codes together
Red & Green
Blue & Yellow
Power
Momentary
Switch Colour Code
2 Core Power cablekeep as short as possible
If extended consult cablegauge guide (Page 6)
Note: Only one master light should be installed per light system
3
EOS Mini / EOS Mini WiFi / EOS Operation - Up to 4 Lights
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Distribution Panel
Battery
Extension cables available (see cable extension
table on page 6)
Lumi-Hub
Music
Note: Only one master light should be installed per light system
Install Switch terminator
PN: 39-0091
Install DMX terminator
PN: 24-0087
2 Core Power cablekeep as short as possible
If extended consult cablegauge guide (Page 6)
Note: EOS Mini & EOS Mini WiFi
To DistributionPanel (10.5 - 31 volts)
To third partyDMX Controller
BLUE DMX -
RED + BLACK -
GREEN DMX +
WHITE DMX GND
4
EOS Mini / EOS Mini WiFi / EOS Operation - Up to 8 Lights
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Distribution Panel
Battery
Lumi-Hub
Lumi-Hub
Extension cables available (see cable extension
table on page 6)3 Core extension cables available(see cable extensiontable on page 6)
Music
Note: Only one master light should be installed per light system
Install Switch terminator
PN: 39-0091
Install Switch terminator
PN: 39-0091
Install DMX terminator
PN: 24-0087
2 Core Power cablekeep as short as possible
If extended consult cablegauge guide (Page 6)
Note: EOS Mini & EOS Mini WiFi
To DistributionPanel (10.5 - 31 volts)
To third partyDMX Controller
BLUE DMX -
RED + BLACK -
GREEN DMX +
WHITE DMX GND
5
Cable Gauge Tables
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
12 Volt DC Installation
24 Volt DC Installation
5 Core Cable extensions from Lumi-Hub to Light
Model Length of extension cable from Hub to Battery10ft / 3m 20ft / 6m 30ft / 9m 40ft / 12m 50ft / 15m10 Awg 8 Awg 6 Awg 6 Awg 4 Awg8 Awg
SMX 92SMX 152 6 Awg 4 Awg 2 Awg 2 Awg
Model Length of extension cable from Hub to Battery10ft / 3m 20ft / 6m 30ft / 9m 40ft / 12m 50ft / 15m18 Awg 14 Awg 12 Awg 10 Awg 10 Awg12 Awg
SMX 92SMX 152 10 Awg 8 Awg 6 Awg 6 Awg
AWG to Metric conversion table
AWG Size Cross sectional Area Cable diameter
10864
18161412
2
5.2mm²8.3mm²13mm²20mm²
1mm²1.3mm²2.0mm²3.3mm²
33mm²
2.5mm3.2mm4.1mm5.1mm
0.8mm1.3mm1.6mm2.0mm
6.5mm
Supply Voltage Total Cable Distance from hub to light12V DC / 24V DC
Note: Some 24V DC systems can be extended further. Contact Lumishore for further info
6m (Light cable plus 1 extension cable)Part Number
24-0121
3 Core Cable extensions from Lumi-Hub to Lumi-Hub
Length1m5m
15m
Part Number24-007724-007824-0099
The tables below give the minimum cable gauge required depending on the supply voltage, and distance from the power source to the Lumi-Hub. Please ensure that the correct cable gauge is used in the installation
6
Light Installation
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
Tools Required
Drill/DriverPhillips ScrewdriverDrill Bits
(3.5mm & 13.5mm)Marine Sealant
(Use only 3M 4200)Rags for clean-up
Pilot Hole for Screws9/64” (3.5mm)
Hole for cable and cable gland17/32” (13.5mm)
1. Select a suitable �at surface that is accessible from inside the vessel and ensure the light cable can be run without a problem.
2. With one hole at the bottom centre (see image below), mark and drill the pilot holes for the screws. Drill the power cable hole.
The cable hole must be large enought to accept the cable gland on the back of the light, so that the light sits �ush.
3. Apply a continuous thick bead of sealant approximately 0.6” (15mm) from the edge of the light and around the cable.
Refer to the image above.
4. Push the power cable through the hole and align the light with the pilot hole screws. Ensure the light connector is
kept clean throughout the process.
5. Attach the light using the 3 stainless steel screws by hand tightening with a screwdriver.
IMPORTANT: DO NOT OVER TIGHTEN. DO NOT USE POWER TOOLS TO TIGHTEN SCREWS.
6. Use a damp cloth to wipe o� excess sealant that was squeezed out around the light. DO NOT USE CHEMICAL CLEANERS!
IMPORTANT: REFER TO THE DIRECTIONS ON THE SEALANT TO MAKE SURE IT HAS
FULLY CURED BEFORE LAUNCHING THE BOAT INTO THE WATER.
Rear sideApply sealant
Bottom center
7
Lumishore Smart Lumi-Hub Installation
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
1. Select a site for the installation of the Lumi-Hub. This should be within reach of the cables of the lights that
will be attached to the hub. The hub should be in a dry, well ventilated area. The hub should NOT be mounted
in areas prone to �ooding or excess heat.
2. The hub should be mounted to a �at surface, with room for access to the fuse panel and connectors.
3. Mount the Hub as close to the battery source as possible. Avoid extending the power cable as this can cause a
voltage drop. If the power cable needs to be extended, consult tables on page 6.
4. Remove the clear fuse panel and insert the fuses, as per the fuse table below. Once the fuses are in place,
replace the fuse panel.
5. Connect the power cable to the DC power source. When the smart hub is switched on the 4 LED’s in the
fuse panel will light up.
6. The system is plug and play. The diagrams on pages 2-5 show the smart hub connections. Refer to the system
setup section for further information.
7. If opertating with an EOS or EOS mini controller ensure the switch terminator and DMX terminator are installed
(see page 4 & 5). The system will not function correctly if these terminators are not installed.
Light TypeSMX 92
SMX 152
12V DC4A
7.5A
24V DC3A4A
Fuse table
8
System Operation - Switch Operation
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
1. The Lumi-Switch has two operations – on/o� and momentary. The momentary function has a spring action,
and is operated by pressing the Bottom of the switch. There are two types of momentary function;
short press (press and release) and long press (press and hold for 1 second before release).
The colour cycle advances in the following sequence:
Note: The SMX 92 & SMX 152 lights have built in memory. When they are switched on they will be at the same
setting as when they were switched o�.
For EOS mini Operation refer to relevant EOS user manual
WHITEBLUE
GREENCYANRE
D
LIME
SKYMAGENTA
CYCLE ICE
CYCL
E
SPEC
TRUM
On/Off
Mode
Turn On to powerup the lights
“Quick press” once tocycle through modes
Mode Select
Strobe Mode
“Long press” once toenter Strobe mode
“Quick press” again tochange strobe speed
“Long press” again toexit Strobe mode
9
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected]
LUMISHORE lights require simple cleaning. Lights should be checked every 3 months to ensure the light body and
lens area are free from sea growth. In the event that your light requires cleaning, we recommend the use of a soft
cloth or soft bristled brush.
DO NOT use any abrasive cleaning materials as these may damage the body of the light.
DO NOT use any cleaning �uids that contain solvents, acids or alkalis.
DO NOT clean using pressure washing or sandblasting equipment.
Slight discolouration of body may occur over life. This does not a�ect performance, and is not subject to warranty.
Due to nature and high build quality it may on rare occasions be possible to see small levels of condensation,
this is normal for high power LEDs and will disappear after cooling and does not harm operation in any way.
No chemicals, cleaners, chemical sprays or sandblasting should ever be applied / used on lights — this will
negate warranty
If you have questions or comments, please e-mail [email protected] or call USA (941) 405-3302,
United Kingdom +44(0)208 144 1694, or France +33(0)493 582 537.
LUMISHORE Ltd warrants the SMX92 / SMX152 to be free from defects in workmanship and materials for a period of
two years, starting from the date of original purchase. Misuse, abuse, improper installation, neglect, improper shipping,
damage caused by disasters such as �re, �ood, and lightning, installation by unquali�ed personnel, unauthorized repair
or modi�cation will void this warranty. For the avoidance of confusion and doubt, non-compliance with all installation,
maintenance and operating instructions in this document constitute non-conformance with warranty terms.
Full warranty details are available at www.lumishore.com
Maintenance and Cleaning
Product Support
10
Light Units - Basic Dimensions
www.Lumishore.comLumishore UK Unit 3, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | [email protected]
Lumishore USA 7137 24TH Court East Sarasota, Florida 34234 | (941) 405-3302 | [email protected] 11
SMX92
12mm(0.47in)
15m
m(0
.59i
n)
95m
m(3
.74i
n)
84mm(3.30in)
120°
LED ARRAY SHOWN FOR ILLUSTRATION
PURPOSES ONLY
SMX152
96mm(3.78in)
120°
12mm(0.47in)
18m
m(0
.71i
n)
110m
m(4
.33i
n) LED ARRAY SHOWN FOR ILLUSTRATION
PURPOSES ONLY
Note : The system uses a master light to synchronise the system. Install only ONE master light per system. The cable will be labelled ‘Master’ (just behind the light)
and marked with a (Red) colour marker at the end of the cable.
Top Related