FBR-100AN monitors operation of CNC machines, and transfers data to the factory monitoring system/server. It supports MTConnect communication protocol, which is used by itoring host, which traditionally is done using
a PC. It also supports wireless bridge functionality which eliminates the use of wiring and cables in the factory. FBR-100AN allows machine tool manufacturers, system integrators, and their users to collect machine tool operation data in the factory and connect to a more sophisticated wired /wireless LAN system.
Features
Product Summary
• Connect to Multiple Networks in the FactoryThis product supports three LAN interfaces. By using two independent wired LAN ports, it is possible to connect to a factory network divided into information and control systems. In addition, you can connect to the network without worrying about the installation location of the machine by using the wireless (IEEE 802.11a/b/g/n).
Smart Connectivity for Factory Machines
FBR-100AN
Bridges factory machines and monitoring systems using MTConnect.
MTConnect Protocol Support
FBR-100AN supports MTConnect protocol for comunication. This protocol is widely adopted by machine tool manufacturers in the United states. By using the MTConnect
transferred to the host system with the FBR-100AN.
Ideal for Factory UseThe product supports the operating temperature, drip-proof, vibration-proof, DC power input/surge treatment, DIN rail mounting required in general factories.
FBR-100AN / MTConnect Communication
* The following tools are available from Silex for the conversion of CNC Device Data to MT Connect XML data:• Point File Creation Tool• Device Information Creation Tool
Application Development KitSilex offers an application development kit that can help add functions whichmay be specific to your machine manufacturer.
Wired LAN Control System
Wired LAN Information SystemFBR-100AN
CNC Machine Tools
LAN Information SystemWireless Access Point
Factory Network Structure
WLAN
* Can be mounted using a commercially available DIN rail mounter.
High Temperature
Compatible with FANUC CNC Machines
Wired LAN Control System
LAN Network
FBR-100AN
CNC Machinee Tools with LAN
Configuration with CNC Machine sInternet Connection
Factory MonitoringSystem
Legacy CNC Machines
TowerSignal
Wired LAN/IP RS-232C/DPRNT Digital I/O
Development Kit (DVD)
FBR-100AN Application Development
CNC Comm
Edge Application
Host Data Transfer
CNC Machine
API
CNC Device Data XML Data
FBR-100AN(MTConnect Server)
Monitoring System(MTConnect Client)
ADAPTER AGENT
01011001101
</>XML
HTTP
Data Conversion*
FBR-100AN
The FBR-100AN is compatible with FANUC machines and can easily be connected to any FANUC CNC device to monitor machine tool NC programs and PMC data operations. Wired LAN and RS-232C interface can be used. Furthermore, by using the digital input interface of this product, CNC data can be collected on legacy machines that obtain operation information via the signal tower. Upto three CNC machines can be connected to collect machine information with one FBR-100AN.
•
•
•
Cold Temperature
Drip-Proof Dust-Proof VibrationResistant
DC12-24VPower Supply
Digitial In / Out *
•
Smart Connectivity for CNC Machines FBR-100AN
Product Speci�cations Mechanical Speci�cation
Size : mm
Hardware
NXP i.MX6 SoloX (792MHz)CPU
256MBRAM
Onboard eMMC: 2GB (Pseudo SLC: 1.2GB available to users)Built-in Storage
Processor and Memory
Product Items
Enclosure
Resin CaseForm
230 x 105 x 36mm (Excluding Antenna)Dimensions
450g (Exluding Antenna)Weight
Any questions about the product?Contact our customer support team! https://www.silextechnology.com/support/contact-silex-support
Wired LAN
IEEE 802.11a / b / g / n 2T x 2R (external antenna)Wireless LAN
D-Sub9 male x1 port (RS-232C / 422A / 485 serial * 1 switching)Serial
3bit (for input of external equipment information such as signal tower * 2 Digital input)
Digital Input
Power Supply: AC adapter (sold separately); DC12-24V Power Consumption: 24V / 0.28A
Power Supply
Interfaces
PUSH switch x1 (for initialization) DIP switch 4bit (for device setting) switchSwitch
LED 2 color LED x4
Communication Protocols
FANUC CNC Machines and ToolsCNC Device Compatibility
MTConnect ver.1.3.1Software: FANUC MT-LINKi ver.3.6
Host System CommunicationProtocol
Environmental Specifcations · Reliability
Operating temperature -20 ~ 50 ℃Operating humidity 20 ~ 90% RH (no condensation)
Operating Environment
HTTP(S), DHCP, NTP, FTP(Client/Server)Other Protocol Support
Wireless STA, IEEE 802.1X authentication (EAP-TLS / PEAP)Wireless LAN Communication
Storage temperature -20 ~ 55 ℃ Storage humidity 20 ~ 90% RH (no condensation)
Storage Temperature
IP53 compliant (includes protective cap / connector, wall mounting)
Dust Proof ・ Dip Proof
Sine wave 1.0G (XY direction) 10 to 500HzVibration Resistant
Anti-static: Contact discharge ± 4kV Air discharge ± 8kV Noise: Power supply line ± 2kV Signal line ± 1kV
Anti Static ・ Noise
40 ± 2℃/80 ± 5% RH/15ppm (H2S hydrogen sul�de gas)/96HCorrosion Resistant
Certi�cations
3 yearsWarranty
Antenna *(Sold Separately)
IP67 Compliant ProductDust / Waterproof Antenna
2.9m CableExtension Cable
DVD with development environment and documentation
Development Kit
Call Silex
Main Unit Main unit, standard antenna, warranty card,Setup Guide, Simple Declaration of ConformityFBR-100AN $ 599
Item IncludesProduct Name MSRP
Cable * (Sold Separetly)
Software (Sold Seperately)
call Silex
Call Silex
* May be required for special installation inside the control panel.
230
105
(215)
36
External Interfaces
Digital InputInterface
Network Port(RJ-45 Connector)
DC ConnectorTerminal
DC Jack (For AC Adapter)
Serial Port(D-Sub9 Male)DIP SwitchPUSH Switch
PIN
1
2
3
4
5
6
7
8
9
RS-232C
DCD [in]
RxD [in]
TxD [out]
DTR [out]
GND [-]
DSR [in]
RTS [out]
CTS [in]
RI [in]
RS-422A/RS-485
TxD- [out]
TxD+ [out]
RxD+ [in]
RxD- [in]
GND [-]
■ Serial Port Pin Assignment Digital Input Pin Assignment
■ DC Connector Pin Layout
DC connector used: J02 S02B-F32SK-GGXR (LF) (AU)Use JST JFA connector J300 series F32FSS-02V-KX for connection to this connector.
Signal
DIN0
DIN1
DIN2
Comments
PIN
1
2
Signal
DCIN
GND
Description
DC 12-24Vin± 5%
GND
RJ-45: x2 (MAC address x2) 10Base-T / 100Base-TX / 1000Base-T (automatic recognition)
12
15
69
COM+
DIN0DIN1
DIN2
COM-
EMCJapan : VCCI Class-A USA : FCC Part15 Subpart B Class-ACanada : ICES-003 Issue 6 Class-A EU : EN55032 Class-A, EN301489-17
Radio Regulatory Certi�cationsUSA · Canada · EU · Japan
RoHSEU RoHS directive
■
On: The external input is low.
O�: The external input is High.
silex technology is a registered trademark of silex technology, Inc. Other product or brand names may be registered trademarks or trademarks of their respective owners.Technical information and specications are subject to change without notice. © 2019 silex technology, Inc. All rights reserved.
US O�cesilex technology america, [email protected]
Europe O�cesilex technology europe, GmbH+49-2154-88967-0Germany toll free [email protected]
Chinasilex technology beijing, [email protected]
silex global sales & support locationsCorporate Headquarterssilex technology, [email protected]
PN: 141-xxxxx-xxxREV A. 20190830
Top Related