AquAtic 1
Owner’s Manual & InstallatIOn GuIde
Note:Readallinstructionsbeforeproceedingwithinstallation.Allspecificationsare±1/4’’andaresubjecttochangewithoutnotice.
SER
ENitY
ser
Ies
2 AquAtic
TABLE OF CONTENTS
PrOduCT rEgiSTrATiON iNFOrmATiON 3CONgrATuLATiONS! 4SAFETy iNSTruCTiONS 5iNSTALLATiON iNSTruCTiONSPre-installationProcedures 6StructuralPreparation 7FactoryinstalledtileFlange 8Plumbing 9Rough-inMeasurements 10Electricalinstallation 11chromatherapyLEDLighting 12VariableSpeedAirBlowerRemoteMounting 13installationinstructionsforFreestandingModels 14VariableSpeedAirBlowerRemoteMountingforFreestandingModels 17Serenity27installationandMaintenanceinstructions 20
OPErATiONElectroniccontrolPanel 23Purgecycle 23AutomatedDrycycle 23Purge24Hours 24RemotecontrolOperation 24
mAiNTENANCE ANd CArEcleaning 26Flushing/Sanitizing 26SurfaceScratchRemoval 26Repair 26Fccinformation 27SerialNumber-HowtoLocate 27
TrOuBLEShOOTiNg guidE Symptoms/PossibleProblems/Solutions 28
PArTS OrdEr FOrm/PArTS mAP/PArTS LiSTPartsMap 28PartsList 29ReplacementPartsOrderForm 30
AquATiC LimiTEd wArrANTy 31
AquAtic 3
YourproductwarrantyisregisteredandconfirmedwithAquaticthroughtheSerialNumberonyourunit.YoudonotneedtocontactAquatictoconfirmregistration.Pleasefillouttheinformationbelowandreferencewhencontactingthedistributortoexpeditewarrantyclaims.
OwNEr iNFOrmATiON:
model Name
Serial Number (SeetableofcontentsforLocation)
Purchase date
distributor
AquATiCProductRegistrationinformation
8101E.KaiserBlvd.•Anaheim,cA92808(800)877-2005•Fax(714)998-5340
www.aquaticbath.com
4 AquAtic
CONgrATuLATiONS!
NOTE: theinstallationandserviceofyourairbathshouldbe
performedONLYbyaqualifiedelectrician,technicianorplumber.
Youhavechosenoneofthefinestbathproductsintheworld!Aquaticsupportsyourpurchasewithstrongcommitmentstoqualityandcustomersatisfaction.
PleasereadandfollowalloftheinstructionscontainedinthisOwner’sManualbeforeinstalling,operatingormaintainingyourairbath.inaddition,youshouldcontinuallyrefertotheseinstructionsduringthelifeofyourairbath.Failuretocomplywiththeseinstructionsmayinvalidateyourwarranty.ifyouhaveanyquestionsconcerninginstallation,operation,maintenanceoranyotheraspectofyourairbath,pleasecontact:
imPOrTANT!
thisproductmuST BE wATEr-TESTEdandinspectedpriortoinstallationorwarrantywillbevoided.Seepage6forinstructions.
PLEASE ChECK ENTirE uNiT FOr ANy dAmAgE. ifitappearsdamaged,contactyourAquaticDistributorimmediately.Aquaticwarrantydoesnotcoverdamagethatoccursintransit.
Aquatic CuSTOmEr SErViCE CENTEr: 800-945-2726(The Troubleshooting guide on page 28 may be helpful in answering some of your questions.)
AquAtic 5
imPOrTANT SAFETy iNSTruCTiONS wArNiNg:wHENuSiNgtHiSuNit,tHESEBASicPREcAutiONSSHOuLDBEFOLLOwED.
thismanualcontainsinformationandinstructionsforproperoperationandmaintenanceofyourairbath.Failuretofollowtheseinstructionscouldresultinpersonalinjury,electricalshockorfire.
rEAd ANd FOLLOw ALL iNSTruCTiONSdANgEr! TO rEduCE ThE riSK OF iNjury:
1. Donotpermitchildrentousethisunitunlesstheyarecloselysupervisedbyanadultatalltimes.Supervisionisalsorequiredwhenairbathisusedbyanelderlyorhandicappedindividual.
2. usethisunitonlyforitsintendeduseasdescribedinthismanual.Donotuseattachmentsnotrecommendedbythemanufacturer.
3. thewaterinanairbathshouldneverexceed40°c(104°F).watertemperaturesbetween38°c(100°F)and40°c(104°F)areconsideredsafeforahealthyadult.usetimeshouldbelimitedtoapproximately30minutes,followedbyashowertocooldown.Longerexposuresmayresult inhyperthermia.thesymptomsofthisconditionarenausea,dizzinessandfainting,whichcanbefatal.Lowerwatertemperaturesarerecommendedforextendeduse(exceeding10-15minutes)andforyoungchildren.
4. Sinceexcessivewatertemperatureshaveahighpotential forcausingfetaldamageduringtheearlymonthsofpregnancy,pregnantorpossiblypregnantwomenshouldlimitairbathwatertemperaturesto38°c(100°F).
5. theuseofdrugsoralcoholicbeveragesbeforeorduringairbathusemayleadtounconsciousnesswiththepossibilityofdrowning.Neverusetheairbathwhileundertheinfluenceofalcohol,anticoagulants,stimulants,antihistamines,vasoconstrictors,vasodilators,hypnotics,narcoticsortranquilizers.
6. Personswithamedicalhistoryofheartdisease,loworhighbloodpressure,circulatorysystemproblems,ordiabetesshouldconsultaphysicianbeforeusinganairbath.
7. Personsusingmedicationshouldconsultaphysicianbeforeusinganairbathsincemedicationmayinducedrowsinesswhileothermedicationmayaffectheartrate,bloodpressureandcirculation.
dANgEr:toreducetheriskofinjury,enterandexitthebathslowly.
wArNiNg:Neveroperateelectricaldevicesinornearthebath.Neverdroporinsertanyobjectintoanyopeningwithintheairbath.
thisunitmustbeconnectedtoasupplycircuitthatisprotectedbyagroundFaultcircuitinterrupter(gFci).Suchadeviceshouldbeinstalledbyalicensedelectricianandshouldbetestedonaregularbasis(atleastmonthly).totestthegFcipushtheTESTbutton.thegFcishouldinterruptthepower.PushtherESETbuttonandthepowershouldberestored. ifthegFcifailstooperateinthismannerthereisthepossibilityofanelectricshock.dO NOT uSE.Disconnecttheunitandhavetheproblemcorrectedbyaqualifiedservicetechnician.toavoidthepossibilityofpersonalinjuryanddiscolorationoftheacrylicsurface,theinletwatertemperatureshouldnotexceed60°c(140°F).thebathshouldbedrainedaftereachuse.Eachbathershouldstarttheirbathwithfreshwater.
CAuTiON:DONOtuSEHARSHABRASiVESORSOLVENtSFORcLEANiNgtHiSuNit.
iNSTALLEr/OwNEr BEArS ALL rESPONSiBiLiTy TO COmPLy wiTh ALL STATE ANd LOCAL COdES whEN iNSTALLiNg ThiS PrOduCT.
SAVE ThESE iNSTruCTiONS
6 AquAtic
PLEASE NOTE: ThE mANuFACTurEr ACCEPTS A 1/4” VAriANCE. ThErE ArE VAriATiONS ON EACh TuB ANd SPECiFiCATiONS ArE SuBjECT TO ChANgE AS wE imPrOVE uPON Our PrOduCT AS rEquirEd.
ThE dimENSiONS NEEdEd FOr SiTE PrEPArATiON ANd STruCTurE BuiLdiNgS ShOuLd BE mEASurEd FrOm ThE TuB; AquATiC ASSumES NO rESPONSiBiLiTy FOr PrEPArATOry wOrK.
Note: A good knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation. we recommend that a qualified licensed contractor perform the installation of all Aquatic products. Our warranty does not cover improper installation problems.
1. immediatelyuponreceivingyourAquaticairbath,inspectitthoroughlyforfreightdamage.ifnecessary,contactyourdistributorimmediately(yourdistributormustcontactAquaticwithin24hoursofreceivingunittofileaclaim).Shouldinspectionindicateanydamage,donotinstallthebath.
2. All bathsare filledwithwater andoperated inourmanufacturing facilityprior to shipment. inspectors ensurewatertightoperation,however,roughhandlingmaycauseleakswhichmaybedetectedpriortoinstallation.
damage or defect to the finish claimed after the bath is installed is not covered under the warranty.
TO iNSPECT:1. Placethetubinanareawhereitmaybedrainedaftertesting.2. Fillthetubwithhotwater(approximately1000F)totheoverflowandallowtostandforafewminutes.carefully
inspectallfittingsandconnectionsforleaks.3. Pluginblowercontrolboxandrunblowerfor10minutes.4. inspectthetubcompletely.AnydefectmustbereportedtoAquaticpriortoinstallationinordertohaveitcoveredby
warranty.Shouldinspectionindicateanydamageorleaks,do notinstallthebath.5. checktoensurethatyourinstallationwillconformtoallapplicablecodesandsecurenecessarypermits.Allelectrical
andplumbingconnectionsshouldbemadebyqualifiedelectriciansandplumbers.
damage or leaks claimed after the bath is installed are not covered under the warranty.
wArNiNg: FAiLurE TO FOLLOw ThESE iNSTruCTiONS duriNg iNSTALLATiON wiLL rESuLT iN TErmiNATiON OF ThE wArrANTy:
Donotliftthetubbyanyportionoftheplumbingorblower.Donotstandinthetubduringconstruction.
dO NOT mAKE ANy ALTErATiONS, AddiTiONS, Or dELETiONS TO ThE Air BATh SySTEm BLOwEr Or BATh.
SErENiTy FrEESTANdiNg mOdELS PArTS LiST:thefollowingpartsareincludedwiththefreestandingmodels.PleasecontactAquaticifanypartsaremissing:1. 1-11/2”unioncheckValve-8427Ftgattachedto1-Blower-8000BLw2. 1-controlBox-8075BOX3. 1-Remotecontrol(batteriesinstalled)-10134. 1-infraredSensorattachedto25footcable-10145. 1-KeyPad(withoutchromatherapybutton)-8079BPADxx(priorto2008)or1113PADcL(2008andlater)6. 1-KeyPadcable-25feet-10507. 1-Pipecovertube(seebelowforfinishpartnumbers):(ForSerenity10and37only) 1035- chrome 1036- PolishedBrass 1037- SatinNickel 1038- PolishedNickel 1039- white 1038ORB-OilRubbedBronze
PrE-iNSTALLATiON PrOCEdurES:
iNSTALLATiON iNSTruCTiON guidELiNES
rEAd ALL iNSTruCTiONS CArEFuLLy BEFOrE iNSTALLATiON
AquAtic 7
quiETNESS OF OPErATiON: Aquatichasengineeredtheirairbathsfrombasetoliptoensurequality,value,functionaldesign,andmaximumbathingcomfort.However,installationisaccountableforasmuchas50%ofatub’soperatingquietness.Pleaseensurethefollowing:• thefloorstructureisadequatetosupporttheinstallation.• Forquieteroperationandheatretentionconservation,thewallssurroundingtheairbathmaybeinsulated.*• insulatethetubsurround.*Donotallowanyinsulationtocomewithin3feetoftheblower.theareaaroundtheblower
mustbecleanandfreeofanyforeignmatter.• Leave1/8”to3/16”gapbetweentublipandsurround.*• Spreadabedofcementmortaronthefloororsubfloorundertheairbathtoreducevibrationandnoise.**Notrequiredonfreestandingmodels.Seepages14-21foradditionalinstallationinstructionsforfreestandingmodels.
NOTE:thebathshouldremaininitsshippingcartonuntiltimeofinstallation.
1. Literaturedimensionsareforreferenceonly.installationdimensionsshouldbetakendirectlyfromthetub.Anunob-structedaccesspanelof16”x16”minimummustbeprovidedattheblowerendoftheairbathallowingsufficientclearancetomakefinalconnectionsandforservicingtheblowerandpowerpanel.Accessmaybethroughthewallorplatformapronattheendoftheunit.inthecaseofsunkeninstallations,accessshouldbemadethroughtheceilingbelow.Aminimumventilationopeningof2”x4”fortheblowerisrequiredandshouldbedesignedtodrawinambientairataminimumof72°F.
it is the installer’s responsibility to provide sufficient service access.
make absolutely certain that access panels and/or service openings are properly placed and that all possible areas where service may be required are accessible.
2. install the drain fitting to the bath. ThE drAiN FiTTiNg wiLL PrOTrudE BELOw ThE BASE OF ThE TuB APPrOximATELy 1 1/2”.clearancemaybeneededforthedrainbycuttingawaythesubfloor(wherepossible)orbyblockingbelowthetubasmayberequired.wArNiNg: FACTOry SKirTS dO NOT ALLOw FOr BLOCKiNg uP OF ThE TuB BASE.Allblockingmustbesolidandprovideuniformsupporttothetubbase.
Note: watertight installation of the drain and overflow is the installer’s responsibility. drain and/or overflow leakage is not included in the warranty of this product.
3. tubmustrestentirelyonitsbase.dO NOT SuPPOrT ThE BASE OF ThE TuB By ThE rim.Aquaticstronglyrecommendspreparingabedofwetmortarintheareawheretubistobeinstalledtoassistinlevelingandreducevibrationnoise.carefullylevelunit,ensuringthatuniformsupportisgiventoallareasofthebaseandnoportionofthelipisbearingweight.
4. Frameoutunderthetubrimasshowninoneoftheillustrationsbelow.NOTE:Duetothevarietyofinstallations
possible,framingproceduresotherthanthosedescribedmayberequired.Levelinselectedlocation.Levelfronttobackandacrossbothsides.Aledgeundertherim,oranapronwithoutaledge,maybeconstructedasrequired(seeDiagrams1Aand1Bonpage8).whereinstallationwillbeagainstawall,studwallframingshouldallowforwallsheathingmaterialtorunfulllengthtothefloor(seeDiagram1conpage8).installtubfirmlyagainstsheathingasindicated,withblockingbelowrimtopreventdeflectionormovementoftub.topreventarockingmovementoftubafterinstallation,itisimportanttohaverimincontact,butnotsupportedbyblockingmaterial.
STruCTurAL PrEPArATiON:
iNSTALLATiON iNSTruCTiON guidELiNES
rEAd ALL iNSTruCTiONS CArEFuLLy BEFOrE iNSTALLATiON
8 AquAtic
5. whenplacingthetubonaplatformorcutout(seeDiagrams1Aand1D),theopeningshouldbe1”smallerthanthespecifiedrimdimensions.Extremecaremustbetakeninthistypeofinstallationtoensurethetubwillcometorestentirelyonthebase.
STruCTurAL PrEPArATiON:
wArNiNg: ALL ELECTriCAL CONNECTiONS ShOuLd BE mAdE By A LOCALLy LiCENSEd ELECTriCiAN.
6. Anotherinstallationoptionisthatofatileflange.Aquaticoffersanoptionalfactoryinstalledtileflangeforallrectangularandcorner-unitairbaths.
NOTE:Beforetubisused,theairbathsystemshouldbecleanedinaccordancewiththeproceduresonPage26ofthismanual.
2A
FACTOry iNSTALLEd TiLE FLANgE:
1. install theairbathunitper the instructionsprovided in thismanual.CAuTiON: ThE TiLE FLANgE dOES NOT SuPPOrT ThE TuB!Aledgerboardmustbeprovidedunderthebathrimasindicatedintheinstallationinstructions.takecaretoensuretubisnothangingfromtheledgerboards,asthiswillvoidyourwarranty.
2. usenailsorscrewstosecuretheflangeintothestudsaroundthebath.
3. installwaterresistantdrywallagainstthetileflangeandflushtothetopoftheairbathdeck.installthetileorotherfinishingmaterials.Applyasecondbeadofsiliconebetweenthefirstcourseoftileandthebathdeck.
1A 1B
1C 1d
*does not apply to freestanding models.
iNSTALLATiON iNSTruCTiONS
AquAtic 9
iNSTALLATiON iNSTruCTiONS PLumBiNg:
1. Aftersecuringtubinplace,normalwasteandoverflow,waterspoutandvalvesareinstalledpernormalplumbingprocedures,inaccordancewithallstateandlocalstandards.
2. installstandard1-1/2”traptodrainandoverflow.Beforeproceeding,makefinaloperationalcheckbyfillingtubwithwatertooverflowandoperateblowerfor5minutes.carefullycheckforleaksbothwhileblowerisrunningandafterithasbeenturnedoff.Allowwatertostandintubforatleast30minutesbeforedraining.AquATiC wiLL NOT BE rESPONSiBLE FOr wATEr dAmAgE OF ANy KiNd.
3. whenselectingfillspoutlocation,checktoensurethatspoutis longenoughtoclearthetubrimfromitsdesiredlocation.ifinstallationistobeonthetubdeck,checkthebacksideoftubforadequatespaceforconnectiontowaterlinesandthatthereareno air channels running under that area of the tub rim before drilling or cutting tub.
4. A service accesspanel of aminimumof a 16” squaremust beprovided adjacent to blower and control boxassembly.
10 AquAtic
From center of overflowpipe to outside rim
From center of drain to tub rim
Serenity1 61/4" 13"
Serenity2 53/4" 131/4"
Serenity3 11/2" 101/2"
Serenity4 11/2" 101/4"
Serenity5 13/4" 10"
Serenity6 51/2" 141/4"
Serenity7 21/4" 93/4"
SerenityStudio8 21/2" 14"
SerenityStudio9 21/2" 13"
Serenity10 43/4" 121/8"
Serenity11 43/4" 121/8"
SerenityStudio12 43/4" 121/8"
Serenity13 31/2" 11"
Serenity14 21/2" 151/2"
Serenity15 21/2" 91/2"
Serenity16 53/8" 12"
SerenityStudio17 43/4" 121/8"
SerenityStudio18 31/2" 121/2"
SerenityStudio19 31/2" 103/4"
SerenityStudio20 43/4" 121/8"
SerenityStudio21 21/4" 121/4"
SerenityStudio22 21/4" 101/2"
SerenityStudio23 31/2" 121/2"
SerenityStudio24 23/4" 101/2"
SerenityStudio25 31/4" 12"
SerenityStudio26 2" 10"
Serenity27 13/4" 111/4"
Serenity28Motif 31/2" 121/4"
Serenity29Motif 51/2" 131/2"
Serenity30Motif 31/2" 121/2"
Serenity31Motif 51/2" 131/2"
Serenity32Motif 6" 14"
Serenity33 11/2" 83/4"
SerenityStudio34 23/4" 103/4"
SerenityStudio35 23/4" 103/4"
SerenityStudio36 3" 101/2"
Serenity37 31/2" 11"
Serenity40 13/4" 111/2"
Serenity41 11/2" 111/2"
Serenity42 11/2" 111/2"
rOugh-iN mEASurEmENTS:
B
A
6A
mOdEL A B
iNSTALLATiON iNSTruCTiONS
AquAtic 11
iNSTALLATiON iNSTruCTiONS
wArNiNg: ALL ELEctRicAL cONNEctiONS SHOuLD BE MADE BY A LicENSED, LOcALLY cERtiFiEDELEctRiciAN, iNAccORDANcEwitHtHEREquiREMENtSOFtHENAtiONALELEctRicALcODESANDPROcEDuRES.
wArNiNg:wHENuSiNgELEctRicALPRODuctS,PREcAutiONSSHOuLDALwAYSBEFOLLOwED,iNcLuDiNgtHEFOLLOwiNg:
dANgEr: riSK OF ELECTriC ShOCK!thisunitrequiresonededicatedcircuit,protectedbyagroundFaultcircuitinterrupter(gFci).Roughinwiringtocontrolboxonadedicated120V,15amp,gFciprotectedcircuit.
gFCi’s are not supplied, however we do specify their use. All known code authorities require gFCis.
ELECTriCAL:theblowerisprewiredtoacontrolboxonacord.AgFciprotected,120Volt,15Amp,60HZcircuitwithaservicegroundisrequired,“dedicated”onlytopoweringthebath.
PLEASE NOTE:Becausetheblowerishousedinaplasticnon-conductivehousing,theBlowerdoesnotneedtobegrounded.
dANgEr:Riskof electric shock.Donotalter the factory installedwiring. A licensedelectricianmustprovide the“dedicated”electricalserviceprotectedbyagFci.thelocationofthegFcimustbeaccessibleforregulartesting.uSE COPPEr CONduCTOrS ONLy.
CAuTiON: Before use of the blower, test the gFCi for proper operation. The blower should turn off when the gFCi “Test” button is pushed.
wArNiNg: Prolonged immersions in hotter water may induce hyperthermia.Hyperthermiaoccurswhentheinternaltemperatureofthebodyreachesalevelseveraldegreesabovethenormalbodytemperatureof98.6oF.thesymptomsofhyperthermiaincludeanincreaseintheinternaltemperatureofthebody,dizziness,lethargy,drowsiness,andfainting.theeffectsofhyperthermiainclude(1)failuretoperceiveheat,(2)failuretorecognizetheneedtoexittheairbath,(3)unawarenessofimpendinghazard,(4)fetaldamageinpregnantwomen,(5)physicalinabilitytoexittheairbath,(6)unconsciousnessresultinginthedangerofdrowning.
wArNiNg: The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.
ELECTriCAL iNSTALLATiON:
12 AquAtic
iNSTALLATiON iNSTruCTiONS
tROuBLESHOOtiNgguiDEforuNDERwAtERMOODLigHt:
ChrOmAThErAPy LEd LighTiNg:
AllSerenitymodels*comeequippedwithadigitalcolor-changingunderwater light forsoothingchromatherapy.tocomplementyourbathingexperience,theAquaticelectroniccontrolpanelallowsyoutoselectacoloraccordingtothedesiredeffects.
To Turn your Chromatherapy Lighting System ON:PressthelightbuttononcetoturnthechromatherapyLightonincolorwashmode.Asecondpressofthebuttonwillturnthelightingsystemoff.Subsequentpresseswillmovethelightingsystemthroughthesevenconstantcolormodes.
• 1st Press Color wash:Randomcolorblend• 2nd Press Off• 3rd Press white:clarity• 4th Press Off• 5th Press Aqua:calm• 6th Press Off• 7th Press Violet:inspiration• 8th Press Off
To replace Bulb:1. Disconnectthepowertoyourbathtub.2. Drainthebathtub.3. OpenthelensofthefixtureusingONLYthepropertoolprovidedforthatpurpose(seeDiagram7A).Donotattempt
toremovethelenswithouttheprovidedtool.4. ReplaceyourLEDlight(replacementLEDlightscanbeobtainedfromAquatic).5. Verify“O”ringisnotdamagedandisproperlypositionedinthegroovewhenreplacingthelens.ifthereisdamage
orlensdoesnotsealproperly,donotrefillbathtub.
NOTE: do not twist LEd light into socket. use gentle pressure and push LEd light into place.
7A
• 9th Press Blue:Peace• 10th Press Off• 11th Press yellow:Hope• 12th Press Off• 13th Press green:Harmony• 14th Press Off• 15th Press red:courage
*does not apply to freestanding models.
Bath Surface
AquAtic 13
iNSTALLATiON iNSTruCTiONS
rELOCATiNg ThE VAriABLE SPEEd Air BLOwEr: Allelectricalconnectionsshouldbedonebyalicensedelectrician.theblowerandcontrolsareinstalledatthefactory.ifyouwishtoinstalltheblowerforamoreconvenientaccess,pleasefollowtheinstructionsprovidedbelow.
dESigNATiNg A rEmOTE LOCATiON:thedesignatedlocationfortheblowermustnotrequiremorethan15feetofpipeand6directionalchanges.chooseaplaceasclosetothebathaspossibletomakesurethatthesystemworksproperly.thechosenplacemustnotbeclutteredand/ordustyandmustallowforsufficientaircirculation.theblowermeasures6”wx10”Lx6”H.theblowercontrolboxmeasures4”wx4”Lx3”H.thisspacemustnotbesmallerthan4cubicfeetandmusthaveaventilationopeningnotsmallerthan2”x4”.theairaroundtheblowershouldbeapproximately72°F(20°c)orhigherforoptimalperformance.
• theblowerandcontrolboxmustbeaccessibleatalltimes.• theextensioncordsmustbeabletoreachthecontrolboxandberoutedperlocalcoderequirements.
rEmOViNg COmPONENTS FrOm ThE BASE:1. Disconnectthekeypadcablefromthecontrolbox,andthenaddtheextensioncable.2. Disconnecttheblowercablefromthecontrolbox.3. Disconnectthechromatherapy lightwiringfromtheconnectorsatthecontrolbox,andthenaddtheextension
cable.BecarefulwhendisconnectingthechromatherapyLEDlightconnectors.Holdtheconnectors,notthewires,sothatthewiresdonotpulloutoftheconnectors.
4. Disconnectthewatersensorwiresfromthecontrolbox,thenaddtheextensioncord.5. RemovethescrewattachingthePVcpipetotheblower.6. RemovetheblowerandcontrolboxfromtheABSsupportbase.
iNSTALLiNg ThE BLOwEr iN A rEmOTE LOCATiON:theblowercanbeinstalledhorizontallyorvertically.theblowerintakemaybeinstalledupordown.usePVc11/2”pipeandadaptersonly.wheneverpossible,usetwo45°elbowsinsteadofone90°elbowtochangethedirectionofyourpipe.glueallpipeconnectionsalongtheextensionyouhaveadded.ButDONOtgluethepipegoingintotheblower;usethescrewyouremovedwhentheblowerwasremoved.
• theblowershouldbe6”offthefloororfromtheceilingandtheairintakeendoftheblowershouldbeatleast4”fromanywallsorjoists.
• toreduceheatloss,insulatethepipe.
MountthecontrolBoxclosetotheblowerandtheAcoutlet.Pluginthekeypadcable,blowercable,waterlevelsen-sorcableandattachthechromatherapyLEDlightwires.(SeeDiagram8B)Nowplugintoaminimum15amp,110vacthatisgFciprotected.
VAriABLE SPEEd Air BLOwEr rEmOTE mOuNTiNg All models except freestanding models
4’’LowVoltagecordtoKeypad
controlBox
6’’
8B
Remoteinstallationinadjacentspace(closet)(exampleonly)
checkValve
BlowerAcOutlet
chromatherapyLEDLight
waterSensorwires(BlackandRed)LocatedbyDrain
to:110vacminimum15ampdedicatedgFciprotectedcircuit
chromatherapyLEDLight-2wires
waterLevelSensor(Notonfreestandingmodels)
toiRSensor(Notused)
toKeyPad
toBlower
Blower
Screws(4)--holdblowertobase
Screw
checkValve
Blower
8A
14 AquAtic
9ANOTE: • Freestandingunitsmustbeplacedonaperfectlyleveled
floor.• theblowermust bemounted in a remote location and
cannotbeinstalledonthebath(seepages17and18).• wallmountedorfreestandingfaucetsmustbeused.
SErENiTy 10 & 37 iNSTALLATiON:For information on electrical installation, maintenance andcare,troubleshootingandwarranty,pleaserefertothetableofcontents.
Beforethefloorinstallationiscomplete,makesureitisperfectlylevel. Oncethefloor installation iscomplete,determinetheexactlocationofthebathandmarkthefloorpositionofthefourclawfeet(seeDiagram9A).The bath must be anchored to the floor.Also,markthepositionoftheholestobedrilledfortheblowerairpassageanddrain.
1. Drillfourholesforthefeet.thendrilla2”holefortheairpassageand2”holeforthedrain.
2. installthedrainandoverflowonthebath.cutpipestodesiredlengthpriortoassembly.Next,gluethefirstsectionofpipe(PVc11/2”) totheairpassageunderthetubandthencoverthepipewiththepipeconcealer(seeDiagram9B).
3. Oncethepipehasbeeninstalledthroughthefloorandthebathhasbeenplaced,securethefourfeetwith1/4”lagboltsorconcreteanchors(seeDiagram9c).
iNSTALLATiON iNSTruCTiONSiNSTALLATiON OF FrEESTANdiNg mOdELS:
9B 9CPipeconcealer cutpipestodesiredlengthpriortoassembly
171/4”
221/2”
SErENiTy 10 BOTTOm ViEw Blower
Fitting
161/2”
201/4”
SErENiTy 37 BOTTOm ViEw Blower
Fitting
AquAtic 15
iNSTALLATiON iNSTruCTiONSSErENiTy 11 & 13 iNSTALLATiON:Before the floor installation is complete,make sure the floor islevel.Oncethefloorinstallationiscomplete,determinetheexactlocationof thebathand trace thecontourof thebathwithanerasablemarkerpen.
For information on electrical installation, maintenance and care,troubleshootingandwarranty,pleaserefertothetableofcontents.
1. Determinetheexactlocationofthedrain,airpassageandthetwoanchoringpointsateachendofthebath(seeDiagram10AforSerenity11and13).
2. Drill2”holesforthedrainandairpassageholes.topreventthebath frommovingsideways, secure the twoanchoringpins(3/8”x3”lagbolts)tothefloor.Leavethelagbolts11/2”abovefloor.wipeoffthemarkertracings(seeDiagram10D).
3. installtheoverflowanddrainonthebath.cutpipestodesiredlengthpriortoassembly.gluethefirstpipesection(PVc11/2”)oftheairpassagetogounderthefloorandmakesurepinsarelinedupwithholesintub.Applyasiliconesealundertherimofthebaseandlaythebathdownputtingthepipesthroughthefloor.immediatelyremoveanyexcesssilicone(seeDiagrams10Band10c).
10B 10C
20” 20”201/2”AnchorPins
10d
SErENiTy 11 SidE ViEw
cutpipestodesiredlengthpriortoassembly
SErENiTy 11 BOTTOm ViEw
10A AnchorPinHoles
20” 20”201/2”
171/4”
221/2”
Blower
Fitting
20” 20”17”AnchorPins
10d
SErENiTy 13 SidE ViEw
SErENiTy 13 BOTTOm ViEw
10A AnchorPinHoles
20” 20”17”
161/2”
201/4”
Blower
Fitting
16 AquAtic
iNSTALLATiON iNSTruCTiONS
Beforethefloorinstallationiscomplete,makesurethefloorislevel.Oncethefloorinstallationiscomplete,determinetheexactlocationofthebathandtracethecontourofthebathwithanerasablemarkerpen.
Forinformationonelectricalinstallation,maintenanceandcare,troubleshootingandwarranty,pleaserefertothetableofcontents.
1. Determinetheexactlocationofthedrain,airpassageandthetwoanchoringpointsateachendofthebath(seefollowingdiagrams).
SErENiTy STudiO 17, 23, 24, 25 ANd 26 iNSTALLATiON:
Serenity Studio 24
BLOwERFittiNg
Serenity Studio 26
BLOwERFittiNg
Serenity Studio 23
BLOwERFittiNg
Serenity Studio 25
BLOwERFittiNg
Serenity Studio 17
BlowerFitting
213/8”
Bottom View
AquAtic 17
dESigNATiNg A rEmOTE LOCATiON:thedesignatedlocationfortheblowermustnotrequiremorethan15feetofpipeand6directionalchanges.chooseaplaceasclosetothebathaspossibletomakesurethatthesystemworksproperly.thechosenplacemustnotbeclutteredand/ordustyandmustallowforsufficientaircirculation.theairaroundtheblowershouldbeapproximately72°F(20°c)foroptimalperformance.theblowerandcontrolboxmustbeaccessibleatalltimes.Seepages18-19forinstallationdiagrams.
iNSTALLiNg ThE BLOwEr iN A rEmOTE LOCATiON:theblowerwillcomeattachedtotheonewaycheckvalve,makesurethearrowonthevalveispointingawayfromtheblower.
theblowercanbeinstalledhorizontallyorvertically.theblowerintakemaybeinstalledupordown.usePVc1½”pipeandadaptersonly.wheneverpossible,usetwo45°elbowsinsteadofone90°elbowtochangethedirectionofyourpipe.glueallpipeconnectionsalongtheextensionyouhaveadded.
theblowershouldbe6”offthefloororceilingandtheairintakeendoftheblowershouldbeatleast4”fromanywallsorjoists.thelocationoftheblowershouldnotbeairtight;agapof1”isrecommendedforgoodaircirculation.toreduceheatloss,insulatethepipe.
mOuNTiNg ThE CONTrOL BOx:MountthecontrolboxclosetotheblowerandtheAcoutlet.(120vacminimum15ampdedicatedgFciprotected).
Youwillbeabletomountboththeinfraredsensorandkeypad(attachbypressuresensitivetapeonbackofkeypad)oryoumaywanttomountonlytheinfraredSensor.whenmountingtheinfraredsensorbesuretherearenoobstructionsbetweenthesensorandthetub.Bothcablesare25feetlong.
Atthecontrolbox,plugthecordfromtheblowerintothecontrolbox,thenplugintheinfraredsensorcordandthekeypadcord,ifitisgoingtobeused.thenpluginthethreeprongplugtoa120vacminimum15ampdedicatedgFciprotectedoutlet.Seecontrolboxwiringdiagramsonpages18,19and21.
Aimremotecontrolattheinfraredsensorandcheck.(SeeRemotecontrolOperationonpages24-25.)
NOTE: Aredlightwillflashrapidlyafterpushinganybuttonontheremotecontrol.iflightdoesnotflashwhenakeyisdepressed,replacethebatteries.
iNSTALLATiON iNSTruCTiONS
2. Drill 2” holes for thedrain andair passageholes. toprevent the bath frommoving sideways, secure thetwoanchoringpins(3/8”x3”lagbolts)tothefloor(seeDiagram10F).Leavethelagbolts11/2”abovefloor.wipeoffthemarkertracings.
3. installtheoverflowanddrainonthebath.cutpipestodesiredlengthpriortoassembly(seeDiagram10g).gluethefirstpipesection(PVc11/2”)oftheairpassagetogounderthefloorandmakesurepinsarelinedupwithholesintub.Applyasiliconesealundertherimofthebaseandlaythebathdownputtingthepipesthroughthefloor.immediatelyremoveanyexcesssilicone.
SErENiTy STudiO 17, 23, 24, 25 ANd 26 iNSTALLATiON (CONT):
10g
10F
VAriABLE SPEEd Air BLOwEr rEmOTE mOuNTiNg FOr FrEESTANdiNg mOdELS:
18 AquAtic
iNSTALLATiON iNSTruCTiONSSerenity 10 & 37
Key Pad
infrared Sensor
ControlBox
Blower
Flow
One way Valve
To 120 vac minimum 15 amp dedicated gFCi protected circuit
Key Pad infrared Sensor
ControlBox
Blower
Flow
One way Valve
SErENiTy FrEESTANdiNg mOdEL CONTrOL BOx wiriNg
To Blower
Not used
Not usedTo ir SensorTo Key Pad
AquAtic 19
iNSTALLATiON iNSTruCTiONSSerenity 11, 13, 17, 23, 24, 25 and 26
Key Pad
infrared Sensor
ControlBox
Blower
Flow
One way Valve
To 120 vac minimum 15 amp dedicated gFCi protected circuit
Key Pad infrared Sensor
ControlBox
Blower
Flow
One way Valve
SErENiTy FrEESTANdiNg mOdELCONTrOL BOx wiriNg
To Blower Not used
Not usedTo ir SensorTo Key Pad
20 AquAtic
iNSTALLATiON iNSTruCTiONSSerenity 27 Copper air Bath
SErENiTy STudiO 27 iNSTALLATiON:Beforethefloorinstallationiscomplete,makesurethefloorislevel.Oncethefloorinstallationiscomplete,determinetheexactlocationofthebathandtracethecontourofthebathwithanerasablemarkerpen.
For information on electrical installation, maintenance and care,troubleshootingandwarranty,pleaserefertothetableofcontents.
1.Determine theexact locationof thedrain,airpassageand the twoanchoringpointsateachendofthebath(seediagramatright).BecausetheSerenity27AirBath ishand-crafted,no two tubsarealikeandmeasurementsforanchoringpointswillvary.
2.Drill2”holesforthedrainandairpassageholes.topreventthebathfrommovingsideways,securethetwoanchoringpins(3/8”x3”lagbolts,notsupplied).Measurethedistancebetweenthecenteroftheanchoringpinholes(seediagram).installthelagboltstothefloorbasedonthismeasurement.wipeoffmarkertracings.
3. installtheoverflowanddrainonthebath.cutpipestodesiredlengthpriortoassembly(seediagramonpage21).gluethefirstpipesection(PVc11/2”)oftheairpassagetogounderthefloorandmakesurepinsarelinedup.Applyasiliconesealundertherimofthebaseandlaythebathdownputtingthepipesthroughthefloor.immediatelyremoveanyexcesssilicone.
4.FindalocationfortheHartfordLoop;youcanmounttheHartfordLoopinsideawalloronawallinanadjacentroom.
5.thetop2inchesoftheHartfordLoopmustbeabovethebottomoftheoverflowhole.(Seediagram)
6.underthetubwillbeaonewaycheckvalve.AttachPVcpipetothisvalveandrunthepipeunderorinthefloortooneendoftheHartfordLoop.
7.Attachtheotherendtotheonewaycheckvalveattachedtotheblower. Bothcheckvalveswillhaveanarrowindicatingairflow.Makesurethearrowspointtowardsthetub.
8. iftheblowerwillbeinstalledinanenclosure,youmustprovideaminimum4”x4”openingforventilation.
BOTTOm ViEw
AnchoringPinLocations
NOTE: Because the Serenity 27 is a one-of-a-kind bath, dimensions may vary up to several inches. Please take all measurements directly from the bath.
AquAtic 21
iNSTALLATiON iNSTruCTiONSSerenity 27 Copper air Bath
theHartfordloopcanbeinstalledinoronawall(seedirections)anchoredtoa2x4.installsothattwoinchesofloopisabovethebottomoftheoverflowhole.
to120vacminimum15ampdedicatedgFciprotectedcircuit
SErENiTy FrEESTANdiNg mOdELCONTrOL BOx wiriNg
Not used
Not usedTo ir SensorTo Key Pad
To Blower
Key Pad
infrared Sensor
ControlBox
BlowerOne way
Valve
2”
Overflow hole
hartfordLoop
Flow
OnewayValveisundertub
Key Padinfrared Sensor
ControlBox
Blower
One wayValve
2”
hartfordLoop
Flow
Overflow hole
One way Valve is under Tub
22 AquAtic
mAiNTENANCE ANd CArESerenity 27 Copper air Bath
CLEANiNg:
· washwithsoapthathaslowacidiccontent(anythingwithacidwillactasapolisher),water,andaNONABRASiVEclothorsponge.
· NEVERuSEanythingabrasive,suchasSoftScrub,cloroxorDranotypeproducts.· DONOtuseacopperpolish.Youwillruinthetub’sfinish.· DONOtuseFlitzFaucetandFixturewax.thisproductwillruinthefinish.· itishighlyrecommendedthatyouuseacarwaxtoprotectthefinishontheexteriorofthetub.· Re-waxexterioroftubwhenneeded.· DONOtwaxtheinteriorofthetub.· thisfinishneedstobetreatedwithextracare.
FLuShiNg / SANiTiziNg:
Beforetubisused,yourairbathandplumbingsystemshouldbeflushed.closethedrain.Fillbathwithhotwatertoatleastsixinchesaboveairinjectorholes.Addtwoteaspoonsoflowsudsingautomaticdishwashingdetergent.DONOtusebleachorotherchlorinatedcleansersonmetalsurfaces.turnbathonforapproximatelytwominutestomixcleanerwithwater.Shutblowerdownandallowcleanertosoakinthebathforapproximatelytwohours.turnonairbathandrunforapproximatelyfiveminutes.turnairbathunitoffanddraintub.Aquaticrecommendstheabovecleaningprocessonyourairbathonceamonth.
The installation and service of your air bath should be performed only by a qualified service technician. remember when contacting your distributor always have your serial number, proof of purchase and model number available. This will ensure a quick response on warranty items. See page 27 for serial number location.
NOtE:ALLwARRANtYREPAiRSMuStBEAutHORiZEDBYAquAticBEFOREwORKiSStARtED.FORSERVicE,ALwAYScONtActYOuRDiStRiButORORAutHORiZEDSERVicEcENtER.
EachSerenitymodelisequippedwitha600wattairheatingsystemtoraisethetemperatureoftheairgoingintothebath.thisairtemperaturewillbelessthanthebathingtemperatureofthewater,butwillhelptoreducearapiddecreaseinwatertemperature.inaddition,theaircomingfromtheairjetswillfeelcoolagainsttheskin,justasabreezeonawarmdaycoolsyourbody.thissystemdoesnotheatthewater.
wATEr ANd Air TEmPErATurE:
AquAtic 23
ELECTrONiC CONTrOL PANEL(seeDiagram11A):1. To Turn Air Bath System On:Pressingtheon/offbuttonwill
turnthebloweronin“constantmode.”thelightindicatorwillilluminatewhenthesystemison.theblowerandtheheaterwillautomaticallyshutoffaftera20-minuteperiod.
2. To Change modes:Pressingthemodebuttonalternates
theblowermodesofoperationfromconstantmodetowavemodeandthentopulsemode.
•Constant mode:consistsofaconstantblowerlevelwithnochange.whentheblowerison,theindicatorlightison.whentheblowerisoff,theindicatorlightisoff.
•wave mode:consistsofagradualchangeofblowerleveltogenerateagentlemassageeffect.thelightindicatorwillalsofollowtheblowerintensity.
•Pulse mode:consistsofaninstantchangeoftheblowerleveltogenerateamassageeffect.thelightindicator
willalsopulseastheblowerdoes.
3. To Change Speeds:inconstantmode,pressingandholdingthe“+”buttonwill increasethevariablespeedoftheblowertothemaximum.Pressingandholdingthe“—”buttonwillreducetheblower’svariablespeedtotheminimum.inbothcases,theusercanreleasethebuttonatthedesiredpowerlevel.NOTE:inwavemodeorpulsemode,the“+”or“—”buttonswillworkthesamewaybutwillhaveaneffectonthemaximumpowerofthewaveandpulsemode.
4. To Turn Chromatherapy Light On:PressthelightbuttononcetoturnthechromatherapyLightonincolorwashmode.Asecondpressofthebuttonwillturnthelightingsystemoff.Subsequentpresseswillmovethelightingsystemthroughthesevenconstantcolormodes.
CAuTiON: due to the varied size, weight and shape of a person’s body, water may splash out of the tub when the air blower is on high speed. Turn the speed of the blower down using the minus button to a lower setting to reduce the amount of water being dispersed from the tub.
NOTE: ThE CONTrOL PANEL ON ThE FrEESTANdiNg mOdELS dOES NOT iNCLudE A ChrOmAThErAPy LighT BuTTON.
Air BATh PurgE CyCLE:Followingthe20minuteruntimeoftheblower,therewillbea15minuteidleperiod.theblowerwillthenturnonfor3minutesforthepurgecycle.iftheuserturnsthebloweroffmanuallybeforethetimerreaches20minutes,theidleperiodwillstartaftertheblowerhasbeenturnedoff.Duringthe15minuteidleperiodandthe3minutespurge,thelightindicatoroftheon/offbuttonwillblink.Duringtheidleperiod,pressingtheon/offbuttonwillturnontheblowerinconstantmode.Duringthe3minutepurge,pressingtheblowerkeywillstopthepurge.
AuTOmATEd dry CyCLE:regardless if the air bath system was utilized, an automated dry cycle will turn on 20 minutes after the water sensors do not detect water.theautomateddrycyclewillturnonfor3minutes(oncethesensorsaredry)topurgetheairchannelsafteranycontactwithwater,includingafterashowerorcleaning/rinsingofthebath.thetwowatersensorsarelocatednearthedrain.Notincludedonfreestandingmodels.
OPErATiON of SErENiTy aIr BatHs
BAThSidE CONTrOL SySTEmS:
On/OffButton
ModeKey
DecreaseSpeed
increaseSpeed
chromatherapyLight(notincludedon
freestandingmodels)
indicatorLight
11A
24 AquAtic
PurgE 24 hOurS:itispossiblefortheusertoprogramapurgecyclethatwillstarteverydayforadurationof1minute.Aquaticstronglyrecommendsactivatingthisfeature.thepurgecyclewillhelpensurethattheairchannelsstaydryevenwhenyouhavetakenasoakingbathorshower.
toactivatethispurgefeature,theusermustholddownthe“+”buttonfor5secondswhentheblower/heaterisofforwaitingforthenormalpurge.then,thelightindicatorontheon/offbuttonwillblinktwice.iftheunitwasinstandbyforanormalpurgewhenthe24hourpurgewasactivated,thenormalpurgewillbecancelled.
toshowtheuserthatthe24hourpurgeisactivated,thelightindicatorontheon/offbuttonwillblinkataslowrate.Adifferentblinkingratewaspickedinordertomakeiteasierfortheusertodifferentiateitfromthestandbyoftheregularpurgecycle.
thepurgewillbedoneeverydayatthesametimetheuseractivatedit(pressedthe“+”button).Bypressingthe“+”buttonagain,the24hourpurgewillbedeactivatedandthelightindicatorontheon/offbuttonwillstopblinkingandturnoff.
OPErATiON of SErENiTy aIr BatHs
rEmOTE CONTrOL OPErATiON:
theSerenityAirBathSystemprovidesavariablespeedcontrolledheatedairblowerwiththreemassagemodes:continu-ousmode,wavemodewithgraduallyvaryingblowerintensities,andapulsemodewiththeblower’sspeedchangingrapidlyfromitsminimumspeedtoauserdefinedmaximumspeed.thechromatherapyLEDlightisalsocontrolledfromtheremotecontrol(chromatherapylightisnotavailableonfreestandingmodels).Abuilt-intimershutsthebloweroff20minutesafterithasbeenactivated.todrytheplumbingsystem,anautomaticpurgecyclewillrestarttheblowerforthreeminutes,15minutesaftertheairbathhasbeenturnedoff.
DEcREASEBLOwERSPEED
BLOwERON/OFF
BLOwERMODE
cHROMAtHERAPYLigHt
iNcREASEBLOwERSPEED
12A LED
OPErATiON of SErENiTy aIr BatHs
AquAtic 25
OPErATiON of SErENiTy aIr BatHs
To Turn Air Bath On:Pressingtheon/offbuttonwillturnthebloweronin“constantmode”.Oncetheblowerison,pressingasecondtimewillturnthebloweroff.theblowerwillshutoffaftera20-minuteperiod.
To Change modes:Pressingthemodebuttonalternatestheblowermodesofoperationfromconstantmodetowavemodeandthentopulsemode.
To Change Speeds:inconstantmode,pressingandholdingthebuttonwillincreasethepowerleveloftheblowertothemaximumspeed.Pressingandholdingthebuttonwillreducetheblower’spowerleveltotheminimum.inbothcases,theusercanreleasethebuttonatthedesiredpowerlevel.
inwavemodeorpulsemode,theorbuttonswillworkthesameway,butwillhaveaneffectonthemaximumpowerofthewaveandpulsemode.
To Operate Chromatherapy Light*:PressthelightbuttononcetoturnthechromatherapyLightonincolorwashmode.Asecondpressofthebuttonwillturnthelightingsystemoff.Subsequentpresseswillmovethelightingsystemthroughthesevenconstantcolormodes.
*Chromatherapy Light function is not available on freestanding models.
Forbestresults,pleaseremovetheremotecontrolfromthewaterwhentheairbathisnotinuse.Prolongedexposuretothehotwaterinyourbathmaycreatehumiditybuild-upinsideyourremotecontrol.thiswillnotaffecttheoperationoftheremote,butmayalteritsappearance.
rEPLACiNg ThE BATTEriES:Aredlightwillflashrapidlyafterpushinganybuttonontheremotecontrol.iflightdoesnotflashwhenakeyisde-pressed,replacethebatteries.
theremotecontrolispoweredbytwoAAAbatteries.1. unscrewandremovebottomcaptoremotecontrol.2. insertnewbatteries,makingsuretomatchplus(+)endswithplusmarkingsonthebatterycase.Refertothelabel
underyourremote.3. Replacecapensuringthatwaterproofgasketsarecorrectlypositionedandcapiswellscrewedon.
NOTES:• Youcanuseacointounscrewcap.• whenreplacingbatteries,itisrecommendedtoaddalubricant(e.g.Vaseline)oncapgasketstoensureperfect
watertightness.
rEmOTE CONTrOL OPErATiON:
26 AquAtic
mAiNTENANCE ANd CArE
usecommonhousehold,nonabrasivecleanersformostcleaningjobs.cleangrease,oil,paintandinkstainswithisopropyl(rubbing)alcohol.Rinsewellanddrywithacleanclothorsponge.Donotruntheairsystemwithfoamingcleanersorsoaps.Rinsethebaththoroughlyaftercleaning.DonotallowyourLucite®acrylicsurfacetocomeintocontactwithproductssuchasacetone(nailpolishremover),nailpolish,drycleaningsolution,lacquerthinners,gasoline,pineoilorothertoxicandoilycleaners.
Beforetubisused,yourairbathandplumbingsystemshouldbeflushed.closethedrain.Fillbathwithhotwatertoatleastsixinchesaboveairinjectorholes.Add2teaspoonsoflowsudsingautomaticdishwashingdetergentandnomorethan4ouncesofbleachtothewater.DONOtusebleachorotherchlorinatedcleansersonmetaltrimsurroundingcontrolpanel.turnbathonforapproximatelytwominutestomixcleanerwithwater.Shutblowerdownandallowcleanertosoakinthebathforapproximatelytwohours.turnonairbathandrunforapproximatelyfiveminutes.turnairbathunitoffanddraintub.Aquaticrecommendstheabovecleaningprocessonyourairbathonceamonth.
Minorscratchesmayberemovedbypolishingyourtubwithanon-abrasivecarpolish,followedbybuffing.Deeperscratchescanberemovedby:
• Sandingwithwet400gritsandpaper.• Sandingwithwet600gritsandpaper.• Sandingwithwetmicro-gritsandpaper.• Buffoutusingcarpolish.
The installation and service of your air bath should be performed only by a qualified service technician. remember when contacting your distributor always have your serial number, proof of purchase and model number available. This will ensure a quick response on warranty items. See page 27 for serial number location.
NOTE: ALLwARRANtYREPAiRSMuStBEAutHORiZEDBYAquAticBEFOREwORKiSStARtED.FORSERVicE,ALwAYScONtActYOuRDiStRiButORORAutHORiZEDSERVicEcENtER.
CAuTiON:careshouldbetakentopreventinappropriatechemicalscomingincontactwiththeLucite®acrylicsurface.Pleasereadandobserveallinstructionsand/orwarningsoncontainerscontainingsubstancesyoucontemplateapplyingtoyourairbath.Anyfailuretocomplymayvoidyourwarranty.
EachSerenitymodelisequippedwitha600wattairheatingsystemtoraisethetemperatureoftheairgoingintothebath.thisairtemperaturewillbelessthanthebathingtemperatureofthewater,butwillhelptoreducearapiddecreaseinwatertemperature.inaddition,theaircomingfromtheairjetswillfeelcoolagainsttheskin,justasabreezeonawarmdaycoolsyourbody.thissystemdoesnotheatthewater.
CLEANiNg:
FLuShiNg / SANiTiziNg:
SurFACE SCrATCh rEmOVAL:
rEPAir:
wATEr ANd Air TEmPErATurE:
AquAtic 27
theairbathactionmaycauseevensmallamountsofbubblebathorshampootofoamexcessively.Exercisemoderationinexperimentingwithdifferentsoapproducts.
Noservicingofthisproductshouldbedonebytheuser.therearenouserserviceableparts.Allcontrolsarelocatedinthecontrolrecessesonthelipofthetub.thesearetheonlycontrolsthatshouldbeusedbytheconsumer.Donotchangeoralteranyofthesecontrolsunderanycircumstances.
Motorsareself-lubricating--Nolubricationrequired.
thisequipmentgeneratesandusesradiofrequencyenergyandifnotinstalledandusedproperly,thatis,instrictaccordancewiththemanufacturersinstruction,maycauseinterferencetoradioandtelevisionreception.ithasbeentypetestedandfoundtocomplywiththelimitsforaclassBcomputingdevice inaccordancewiththespecifications insubpartJofpart15oftheFccrules,whicharedesignedtoprovidereasonableprotectionagainstsuchinterferenceinaresi-dentialinstallation.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.ifthisequipmentdoescauseinterference,whichcanbedeterminedbyturningtheequipmentonandoff,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• Reorientthereceivingantenna.• Relocatethereceiverwithrespecttothebathtub.• Movethereceiverawayfromthebath.• Plugthereceiverintoadifferentoutletsothatthereceiverandbathareondifferentbranch
circuits.• ifnecessary,theusershouldconsultthedealeroranexperiencedradio/televisiontechnician
foradditionalsuggestions.• theusermayfindthefollowingbookletpreparedbytheFederalcommunicationscommission
helpful:“HowtoidentifyandResolveRadio-tVinterferenceProblems.”This booklet is available from the u.S. government Printing Office, washington, dC 20402, Stock No., 004-000-00345-4.
SErENiTy aIr BatHs uSEr iNFOrmATiONPLEASE NOTE:
FCC CONSumEr iNFOrmATiONElectricalinstallationinformationlistedonpage11.
SEriAL NumBEr LOCATiON:thetubmodelandserialnumbersarelocated
abovetheblowerareaonthebacksideofthedrop-inmodels.Yourinstallershouldhaveaserviceaccesspanelinthislocation.thenumbersarelocatedonthebottomofthetubonfreestandingmodels.Lookforalabelwhichresemblestheoneontheright.
28 AquAtic
TrOuBLEShOOTiNg guidEwArNiNg:Alwaysturnoffpoweratthemainelectricalservicepanelwhenservicingyourairbath.
AirBathdoesnotoperate. 1) NopowertoAirBathunit. 1) ResetcircuitbreakersandgFciiftripped. checkfusesandreplaceifbad. 2) BlowercontrolBoxisnotpluggedin. 2) Makesureplugisfullyinsertedintotheoutlet. 3) controlPanelconnectortocontroller 3) checkandreconnectifneeded. boxisdisconnected. 4) BlowerMotorisdisconnectedfrom 4) Plugblowerintocontrolbox. controlbox.Blowerturnsoffbyitselfor 1) Blowermotoroverheatedandthermal 1) checkthattheblowerhassufficientbeforetimeelapses. protectiondevicehasdeactivatedmotor ventilationandthattheintaketothebloweris (possiblylowvoltage). notblocked.clearandallowmotortocool down.(checkserviceandwiresize.) 2) gFcitripped. 2) Refertoinstaller/dealer.
circuitbreakertripsrepeatedly. 1) Defectivebreaker. 1) changeoutbreaker. 2) Shortcircuitbetweenbathand 2) Refertoinstaller/dealer. breakerbox. 3) Otheritemsareconnectedtothe 3) Refertoinstaller/dealer. samecircuit.
Blowerdoesnotmanuallyshutoff. 1) Defectivecontrolpanel. 1) Refertoinstaller/dealer.Replacecontrolpanel. 2) Defectivecontrolbox. 2) Refertoinstaller/dealer.Replacecontrolbox.
AirBathdoesnotfunction 1) Speedofairsettingissettoolow. 1) changetheairspeedsettingtoamid-rangeproperlywhileinthepulseor settingbeforeswitchingtowaveorpulsewavemodes. modes.
SymPTOmS POSSiBLE PrOBLEmS SuggESTEd SOLuTiONS
7) ChrOmAThErAPy LighT
2) CONTrOL BOx
1) Air BLOwEr
4) ANd 14) CONTrOL
PANEL
3) ChECK VALVE
(ONE wAy
VALVE)
5) LighT wALLFiTTiNg
SErENiTy aIr BatHsREPLAcEMENtPARtSORDERMAP
AquAtic 29
SErENiTy aIr BatHsREPLAcEMENtPARtSLiSt
dESCriPTiON PArT NumBEr COLOr / FiNiSh1) AirBlower 8000BLw ------2) controlBox 8075BOX ------3) checkValve 8427Ftg ------4) controlPanel 8075PADwH white 8075PADBR PolishedBrass 8075PADcR chrome 8075PADBN SatinNickel 8075PADcL clear 8075PADORB OilRubbedBronze 1110PADcL(2008andlatermodels) ------5) LightwallFitting(incl.socket) 8260LigHt ------6) LensRemovaltool(notshown) ------ ------7) chromatherapyLEDLight 1055 ------8) SculpturedPillow(option)(notshown) Oval 9604PiLLXX Specifywhite,BiscuitorBlack Rectangle 9601PiLLXX Specifywhite,BiscuitorBlack9) Lift&turnwasteandOverflow 93cPDwO chrome 93PBDwO Brass 93SNDwO SatinNickel 93PNDwO PolishedNickel 93PgDwO gold 93ORBDwO OilRubbedBronze10) cableDrivewasteandOverflow cableDrivewasteandOverflow chrome (option)(notshown) PolishedBrass gold SatinNickel PolishedNickel colorMatched: Bone,white&BiscuitOnly OilRubbedBronze11) Remotecontrol(option)(notshown) 1013 ------ (standardfeatureonFreestandingModels) 12) wasteandOverflowforFreestanding 94cPDwO chrome SerenityModels 94wHDwO white (option)(notshown) 94PNDwO PolishedNickel 94PBDwO PolishedBrass 94SNDwO SatinNickel 94ORBwO OilRubbedBronze13) infraredSensorattachedto25footcable 1014 ------ (notshown)(forremotecontroloption)14) controlPanel(FreestandingModels) 8079BPADwH white (notshown) 8079BPADBR PolishedBrass 8079BPADcR chrome 8079BPADBN SatinNickel 8079BPADcL clear 8079BPADORB OilRubbedBronze 1113PADcL(2008andlatermodels) ------15) 25FootcableforFreestandingModels 1050 ------ controlPanel(notshown)16) Pipecovertube(Serenity10&37only) 1035 chrome (notshown) 1036 PolishedBrass 1037 SatinNickel 1038 PolishedNickel 1039 white 1038ORB OilRubbedBronze17) RemoteBlowerOption ExtensionforKeyPad 1051 ExtensionforwaterSensors 1052 ExtensionforLight 105318.) Bolt-OngrabBar 901806gRAB white (option)(notshown) 901807gRAB Biscuit 901800gRAB chrome 901801gRAB Brass 901802gRAB SatinNickel 901803gRAB PolishedNickel 901804gRAB gold 901805gRAB OilRubbedBronze19.) grabBar 9017wHgRAB white 9017BigRAB Biscuit 901710gRAB chrome 901720gRAB Brass 901760gRAB SatinNickel 901770gRAB PolishedNickel 901740gRAB gold 901780gRAB OilRubbedBronze 4174AcROD clearAcrylic/SpecifyModel#
30 AquAtic
how To use:1.Findyourpartonthemapandmakenoteofitsnumberandletter.2.usingmapnumberandletter,choosepartnumberandselectcolor(orfinish) onpartslistprovidedonpage29.3.Fillouttheformbelowwiththeselectedinformation.FaxorsendtoAquatic.4.callAquaticforpartspricingandshippingcharges.
imPOrTANT!thefollowinginformationmuSTaccompanyyourorder:Serial Number, model Number/Name, Purchase date and Color
PLEASEFiLLOutcOMPLEtELY:
rEPLACEmENT PArTS OrdEr FOrmFOr SErENiTy aIr BatHs
Mailordersto:
AquAtic8101E.KaiserBlvd.•Anaheim,cA92808
(800)877-2005•Fax(714)998-5340
Serial#(invoice#)___________________________ModelName__________________________________
Model#________________________color___________________PurchaseDate_____________
ShiP TO:
Name
company
Address
city State Zip
Phone Fax
quantity Part No. description Color/Finish Price
BiLL TO:
Name
company
Address
city State Zip
Phone Fax
Aquatic Limited Lifetime warrantyFor millennium, infinity, Century, LuxeAir, Luxury, Serenity AirBaths, Serenity Studio, hotSoak and restoration Series
LimitedwarrantyForOriginalconsumerForHouseholdusage
whAT PrOduCTS ArE COVErEdStructuresandsurfacefinishes,pumpsandblowersontheMillennium,infinity,century,LuxeAir,Luxury,Serenityair Baths,SerenityStudio,HotSoak,andRestorationSeries.
warranty Periods for Specific ComponentsLiFETimE wArrANTy FOr whirLPOOL/Air BATh/TuB ShELL, PumP ANd BLOwErAquaticextendstotheoriginalconsumerpurchaseroftheacrylic,fiberglassreinforcedshell,anon-transferablelifetimewarrantythattheshellwillretainitsstructuralintegrityandconfigurationandbefreeofwaterlossduetoadefectinthetubshell.thewarrantycoversthetubshellandthefactoryinstalledpumpandbloweragainstdefectsinmaterialorworkmanship.thiswarrantydoesnotapplytoallothercomponents(attachmentstotheacrylic,fiberglassreinforcedshell,suchasplumbing,fittingsandotherapparatus)becausethesepiecesarecoveredbelowundera2Yearwarranty.
LiFETimE SurFACE wArrANTy FOr FACE OF whirLPOOL/Air BATh/TuBtheinteriorsurfaceiswarrantedagainstfading,blistering,crackinganddelaminationduetodefectsinthesurfacematerialsforlife.thissurfacewarrantyex-tendstodefectsduetosurfacematerialmixingormolding.thissurfacewarrantydoesnotapplytofading,cracking,delaminationorblisteringduetoexcessivewear,sunfadingorscouringduetocleaning.
2 yEAr EquiPmENT wArrANTy FOr SuPPOrT EquiPmENT, COmPONENTS, CONTrOLS & PLumBiNg EquiPmENTAllsupportequipment;components,controlsandplumbingequipmentarewarrantedfor2yearsfromdateofpurchase,butnotmorethan3yearsfromdateofmanufacture,againstdefectsinworkmanshipandmaterials.Lightbulbs,fusesandpillowsarenotincludedinthistwo-yearperiod.However,theseacces-soriesarewarrantedtobefreefromdefectsinmaterialsandworkmanshipatthetimeofdeliverytotheoriginalpurchaser.Limitedlaboriscoveredfor2yearsfrompurchase,butnevermorethan3yearsfromdateofmanufacture,forlimitedlaboronthesupportequipment,controls,andplumbing. ExCLuSiVE rEmEdyAquaticwill,atitsoption,repairorreplace(withoutremovalorinstallation)theaffectedcomponentsofanydefectiveunitorSystem;repairorreplace(withoutremovalorinstallation)theentiredefectiveunitorSystem;orrefundthethen-currentlistpriceofthewhirlpool,AirBath,ortub.inallcases,areasonabletimeperiodmustbeallowedforwarrantyrepairstobecompleted.
whAT yOu muST dOinordertomakeaclaimunderthesewarranties:1. Youmustbetheoriginalconsumerpurchaserofthewhirlpool,AirBath,ortub.2. Youmustpromptlynotifyuswithinthewarrantyperiodofanydefectandprovideuswithanysubstantiationthatwemayreasonablyrequest. writeto: Aquatic 1521 No. Cooper, Ste. 500 Arlington, TX 76011.3. thewhirlpools,AirBaths,andtubsmusthavebeeninstalledandmaintainedinaccordancewithgoodindustrypracticeandthespecificAquaticdirectionscontainedintheOwner’sManualandinstallationguide.
ExCLuSiONSthesewarrantiesdonotextendtoordonotcoverdefectscausedby:1. Shippingdamagebycarriersorinstallationerrors.2. Accident,actsofgod,abuseormisuse.3. unreasonableuse(includinganyusefornon-bathingpurposesorfailuretoprovidereasonableandnecessarymaintenanceasspecifiedinAquaticOwner’s
Manualandinstallationguidesuppliedwiththewhirlpool,AirBathortub).4. Anyalteration,customization,ormodificationofthewhirlpool/AirBath/tuboritscomponents.
LimiTATiONS1. Aquaticwhirlpoolsandtubssoldforindustrial,commercialandhotelusearewarrantedfortwoyears,butnotmorethan3yearsfromdateofmanufacture,
witha2yearlimitedwarrantythattheshellwillretainitsstructuralintegrityandconfigurationandbefreeofwaterlossduetoadefectinthetub.theinteriorsurface/faceofthewhirlpool/airbath/tubiswarrantedagainstfading,blistering,crackinganddelaminationduetodefectsinthesurfacematerialsfor2yearsaswell.Allsupportequipment,components,controlsandplumbingequipmentandlimitedlaboronthesupportequipment,controls,orplumbingarewarrantedfor1yearfromdateofpurchase,butnotmorethan2yearsfromdateofmanufacture.Pumpseals,“O”rings,lightbulbs,fusesandpillowsarenotincludedinthistwo-yearperiod.However,theseaccessoriesarewarrantedtobefreefromdefectsinmaterialsandworkmanshipatthetimeofdeliverytotheoriginalpurchaser.
2. inallcases,AquaticreservestherighttofullysatisfyitsobligationsundertheLimitedwarrantiesbyrefundingthethen-currentlistpriceofthedefectivewhirlpool,AirBath,ortub(or,ifthewhirlpool,AirBath,ortubhasbeendiscontinued,ofthemostnearlycomparablecurrentproduct).
3. tHESEwARRANtiESARENON-tRANSFERABLEtOANYOtHERPuRcHASERORPARtYOtHERtHANtHEORigiNALcONSuMER.NOOtHERAgENtORPARtYcANgiVEANYOtHERwARRANtYORPROMiSE.tHiSiStHESOLEwARRANtYFORYOuRAquaticPRODuct.
4. Aquaticwillnotcoveranyinstallationorreinstallationcostsrelatedtothiswarranty,exceptunderthelimitedlaborallowanceunderthe2YearEquipmentwarrantyabove.
gENErALthiswarrantygivesyouspecificlegalrights;youmayalsohaveotherrights,whichvaryfromstatetostate.tHEDuRAtiONOFANYiMPLiEDwARRANtiES,iNcLuDiNgtHEiMPLiEDwARRANtiESOFMERcHANtABiLitYANDFitNESSFORAPARticuLARPuRPOSE,ARELiMitEDtOtHEDuRAtiONOFtHEEXPRESSwARRANtiESHEREiN.AquaticEXPRESSLYEXcLuDESiNciDENtALANDcONSEquENtiALDAMAgES,tOiNcLuDELOSSOFtiME,iNcONVENiENcE,ORLOSSOFuSEOFRESiDENcE,FORANYBREAcHOFtHEEXPRESSORiMPLiEDwARRANtY,iNcLuDiNgtHEiMPLiEDwAR-RANtiESOFMERcHANtABiLitYORFitNESSFORAPARticuLARPuRPOSE.
SOMEStAtESDONOtALLOwANYLiMitAtiONONHOwLONgANiMPLiEDwARRANtYLAStS,ORtHEEXcLuSiONORLiMitAtiONOFiNciDENtALORcONSEquENtiALDAMAgES;SOtHEABOVEEXcLuSiONMAYNOtAPPLYtOYOu.
SOM109/08
AquAticFax-On-DemandSystem:tollFree(877)618-7024
8101E.KaiserBlvd.•Anaheim,cA92808(800)877-2005•Fax(714)998-5340•www.aquaticbath.com
Top Related