8/7/2019 Samsung Refrigeration Familiarization
1/74
Samsung RefrigerationFamiliarizationR e f ri g er a to r E v a p o ra t o r
May tag Technical Training Services 2003MA
ABSL2003-116
8/7/2019 Samsung Refrigeration Familiarization
2/74
8/7/2019 Samsung Refrigeration Familiarization
3/74
8/7/2019 Samsung Refrigeration Familiarization
4/74
8/7/2019 Samsung Refrigeration Familiarization
5/74
8/7/2019 Samsung Refrigeration Familiarization
6/74
2
Under the freezer hinge cover arethe electrical connections for thefront display panel. All electronicsand control circuits are in the rearcontrol compartment. The displaypanel is just data input and display.
Connections through the upperfreezer door hinge.There is also thermistor to monitorthe exterior temperature under thishinge cover. The thermistor is on avery short harness.
The units use a hot wall condenserin conjunction with a sub-condenser. The hot wall condenserloop is manufactured from steel.The Hot Pipe Post Condenser Loop(Yoder Loop) is constructed fromcopper tubing. There are twoevaporators. The capillary tubefeeds into the fresh food evaporatorand the outlet from the fresh foodevaporator supplies the freezerevaporator.
8/7/2019 Samsung Refrigeration Familiarization
7/74
R e f r i g e r a t o r E v a p o r a to r
S ID E C L U S T E R P IP E
H o t P ip e
3
8/7/2019 Samsung Refrigeration Familiarization
8/74
There are multiple evaporator fanoutlets distributed throughout eachcavity.
Side Views
4
8/7/2019 Samsung Refrigeration Familiarization
9/74
5
The temperature settings willdisplay the current set-point the firsttime that the "Fridge Temp" or"Freeze Temp" buttons are pressed.Each subsequent pressing of thecontrols will decrease the set-pointuntil the minimum is reached.Pressing the control again will cyclethe control to the maximum setting.
Press the child lock button for 3seconds, the child lock indicatorcomes on with an audible tone. Nofunction commands except the icetype button will be accepted. Thisfunction will prevent accidentalsettings. To unlock this function,press and hold the child lock buttonfor 3 seconds.
The ice type button selectsCubed/Crushed/Ice-off options insequence. The default setting isCubed Option. If ice off is selected,the ice maker will stop working, thisoption will be terminated whenCubed or Crushed options areselected.
8/7/2019 Samsung Refrigeration Familiarization
10/74
6
Power Freeze:When the power freeze button isdepressed, the power freezeindicator light comes onimmediately. The compressor andfan run continuously for a set timeand temperature depending onmodel.Power Cool:When the power cool button isdepressed, the power cool indicatorlight comes on immediately. Thecompressor and fan runcontinuously until the refrigeratorreaches 25F.Refer to the service flash. Pre June2003 production Power Freezeoperation differs from post June2003 operation.
Filter indicator light: This indicatorlight is normally green, after 5months of service it changes toorange, at the 6th month it changesto red.To reset: depress the Ice Type andChild Lock buttons for 3 seconds.This is strictly a time-basedfunction, this does not monitorwater usage.
8/7/2019 Samsung Refrigeration Familiarization
11/74
Self-Diagnostic Function
* S e lf- dia gn os tic s c he ck lis tE r r o r
When power is first applied, thesystem performs a power-up selfcheck. Any failure of an activecomponent will result in a specificsegment of the display illuminating.There are two versions of the self-diagnostic output. On unitsproduced before June 2003 will notdisplay for Refrigerator Defrosterrors (7) or Freezer Defrost Errors(13). The self diagnostics can beactivated by pressing the "PowerCool" and "Power Freeze" buttonsat the same time for eight seconds.
I C E -M A K E R S E N S O RP re ss b o th b ut to n s s im u lta ne ou sly fo r 8 s ec on d s
R - S E N S O R
I f a n y L E O s b lin k , th e c o r r e s p o nd in g s e n s o rs a n dc o m p o n e n ts m u s t b e c h e c k e d f o r a n e rr o r.
7
8/7/2019 Samsung Refrigeration Familiarization
12/74
Load Operation Check Function All currently powered (active)components can be displayed byholding down both the "PowerFreeze" and "Power Cool" buttonsfor six seconds followedimmediately by the "Fridge Temp"button. The display will indicateeverything that is currentlyenergized. There is a twenty secondtime-out on this function.
* T a bl e o f L o a d M o d e C h ec k li st
* T ab le o f L o ad M o de C h ec k L is tC o n t e n t s
P re ss b oth b utto ns s im ulta ne ou sly fo r 6 s ec on ds , a llL ED lig hts w ill b e tu rn ed o ff. A t th is tim e p re ss b utto n@
R - F A N H ig h o r A C m o t o r o p e ra ti o nR -F A N L o w
F re e z e r T e m p .. @ , e , eF r i d g e T e m p .@ C D- i ; ' f , - , @-@
8
8/7/2019 Samsung Refrigeration Familiarization
13/74
Set Point Shift Function
Example) If y ou ar e l ow eri ng t he c ur ren t t empe ra tur e of t he f re ez er b y 6. 0'F
9
Offsets are included that will allowfor adjusting to the characteristics ofthe thermistors. Hold the FreezerTemp and Power Cool buttons fortwelve seconds. It is highlyrecommended that theseadjustments are avoided.
The Fridge Temp display showswhich mode the adjustment is beingmade to. There are four differentthermistors that can be adjusted.Freezer offset is mode "0". FreshFood offset is mode "1". Ice Makerthermistor offset is mode "4".CoolSelect zone is mode "20".Icemaker fill time can be adjustedwhen in mode "3". It is stronglysuggested that the icemaker fill timeshould not be adjusted.The Freezer Temp display indicatesthe amount of the offset based uponmemory tables. It is imperative thatthe reference tables be used whenmaking an offset adjustment. Thevalues displayed in the FreezerTemp display are not the actualoffset temperatures.In this example, the freezerthermistor is being offset by -6degrees.
8/7/2019 Samsung Refrigeration Familiarization
14/74
Freezer Temp Sensor Shift
R e fe re n c e V a Ju iS
Co d e s h if t s h ift0 0 8 1.0 'F1 1.0 'F 9 2.0"F2 - 2 .0 'F t o 3.0'F3 3,O'F 1 1 4 .0 'F4 -4 ,OF 1 :2 5.0F5 " " 'S,O'F 1 :3 6.0'F6 ~ 6 .0 'F 1 :4 I .O'F7 7.0'F 1 :5 a .OF
10
8/7/2019 Samsung Refrigeration Familiarization
15/74
In this example, the fresh foodthermistor is being offset by +3.0degrees.E xa mp le ) I f y ou a re r ais in g th e c urr en t te mp er atu re o f the refr igerator by
8/7/2019 Samsung Refrigeration Familiarization
16/74
Icemaker Temp Sensor Shift
It is strongly recommended that theicemaker fill time should not beadjusted.
Two different sets of icemakerthermistor offset adjustments havebeen used. One set is for pre-June2003 production.
4 ) S h if t th e Ic e m a k e r te m p e ra tu re s en so r 4 ) S h if t th e Ic e m a k e r te m p e ra tu re s en so r
R e fe re n ce V al ue
Code I ce m a ke rt empe r at ur e s e n so r0 19 T1 2 f F2 17.5'F3 16 T4 14'F5 12T6 10.5'F7 8S F
Code T c e m a k e rt em p er at ur e s e ns or
4
21'F
14'F12F
10.5',8S F16 T1T F19'F
Pre June, 2003 P o s t J u n e , 2 0 0 3
12
8/7/2019 Samsung Refrigeration Familiarization
17/74
CoolSelect Temp Sensor Shift
i R ef s l' sn c :e " Ja kA e
C o d e C o o lS e le e t Z o n e 1Mt empe ra t ur e s e n so re O F1,OT
2
42,OF
e 3 . , 04,OT7
13
8/7/2019 Samsung Refrigeration Familiarization
18/74
Thermistors are all the same sensorwith different harnesses attacheddepending on the mounting. It ispossible to either check theresistance of the sensor with theconnection unplugged, or check theDC voltage of the sensor.
Thermistor Spec Chart
- 4 : :1 . t i ~ ~ .~ IU 4 .841-41.8 93.700 4.518-40.0 88.850 4.494-38.2 84.150 4.469-36.4 79.800 4.443-34.6 75.670 4.416-32.8 71.800 4.389-310 68.150 4.360-29.2 64.710 4.331-27.4 61.480 4.301-25.6 58.430 4.269-23.8 55.550 4.237-220 52.840 4.204-20.2 50.230 4.170-18.4 47.770 4.134-16.6 45.450 4.098-14.8 43.260 4.061-13.0 41.190 4.023-11.2 39.240 3.985-9.4 37.390 3.945-7.6 35.650 3.905-5.8 33.990 3.863-4.0 32.430 3.822-2.2 30.920 3.778-0.4 29.500 3.7341.4 28.140 3.6893.2 26.870 3.6445.0 25.650 3.5976.8 24.510 3.5518.6 23.420 3.50410.4 22.390 3.456
l1.L L1.41 U :: I.4 U~14.0 20.480 3.36015.8 19580 3.31017.6 18.730 3.26019.4 17.920 3.20921.2 17.160 3.159230 16.430 3.10824.8 15.740 3.05726.6 15.080 3.00628.4 14.450 2.95530.2 13.860 2.90432.0 13.290 2.85333.8 12.740 2.80135.6 12.220 2.75037.4 11.720 2.69839.2 11.250 2.647410 10.800 2.59642.S 10.370 2.54544.6 9.959 2.49546.4 9.569 2.44548.2 9.195 2.39550.0 8.839 2.34651.8 8.494 2.29653.6 8.166 2.24855.4 7.S52 2.19957.2 7.552 2.15159.0 7.266 2.10460.S 6.992 2.05762.6 6.731 2.01264.4 6.481 1.96666.2 6.242 1.922
t i~ .U t i.U1 ::I 1 .~ 1 ~69.8 5.792 1.83471.6 5.581 1.79173.4 5.379 1.74975.2 5.185 1.707no 5.000 1.66778.8 4.821 1.626SO.6 4.650 1.58782.4 4.487 1.54984.2 4.329 1.51186.0 4.179 1.47487.8 4.033 1.43789.6 3.894 1.40191.4 3.760 1.36693.2 3.631 1.33295.0 3.508 1.29896.8 3.390 1.2669S.6 3.276 1.234100.4 3.167 1.203102.2 3.062 1.172104.0 2.962 1.143105.8 2.864 1.113107.6 2.770 1.085109.4 2.680 1.057111.2 2.593 1.030113.0 2.510 1.003114.8 2.429 0.977116.6 2.352 0.952118.4 2.278 0.928120.2 2.206 0.904
14
8/7/2019 Samsung Refrigeration Familiarization
19/74
Defrost Function
15
Since there are two evaporators inthe system, there are two evaporatordefrost heaters.Defrost is adaptive and willterminate based upon the evaporatorthermistor temperature readings.The system is designed to defrostthe fresh food section twice as oftenas the freezer section. Thiscompensates for the fact that thefresh food section is accessed morefrequently than the freezer section.The fresh food section can defrostindependent of the freezer section,but the freezer section will alwaysdefrost at the same time as the freshfood section. The fresh food sectionwill defrost once for every six toeight hours of compressor run timewhile the freezer section will defrostevery twelve to sixteen hours ofcompressor run time.When started from roomtemperature, the first defrost cyclewill begin after four hours ofcompressor run time.The defrost temperature ismonitored at the bottom right of thefreezer evaporator and at the top leftoutlet of the refrigerator evaporator.
8/7/2019 Samsung Refrigeration Familiarization
20/74
Forced Operation Function
16
The forced operation check allows aforced check of the cooling system.Each mode will operate until thenext mode is selected or until thetest is cancelled. The forced modecannot be activated if the unit isdefrosting either of the evaporatorcoils.The compressor will run for 24hours and then begin cycling at -14degrees in the freezer and 34degrees in the fresh foodcompartment.Loss of power will also cancel thisfunction. There is no delay incompressor start so if there is highhead pressure, an overload conditioncan be encountered.The three individual tests are;Forced compressor pull-down,Refrigerator defrost check andrefrigerator and freezer defrostcheck.To enter the forced operation mode,depress the Power Freeze and theFridge Temp buttons for eightseconds.
8/7/2019 Samsung Refrigeration Familiarization
21/74
Press any but ton except " ICE TYPE" or "CHILD
Pressing the "Ice Type" or "ChildLock" buttons will cancel this modeof operation.During each test the timing of thebeeps will vary.
Forced Operation Function
Condenser Fan Delay The condenser fan operation willchange depending on the ambienttemperature. Above 65 degreesFahrenheit, the condenser fan willbegin operation with thecompressor. Between 61 and 65degrees, the condenser fan energizesfive minutes after the compressorenergizes. Below 60 degrees, thecondenser fan will not operate. Thisfunction is used to promote good oildistribution within the compressor.
A b o v e 6 6 "F C - F A N i s O N a s s o o n a s t h e c o m p re s s o r i s o n ,
17
C - F A N i s O N w i t h 5 m i n u t e s d e l a y f r o m t h e c o m p r e s s o r o n ,B e l o w 6 0 ' ' F C - F A N i s O F F r e g a r d l e s s o f t h e c o m p r e s s o r o p e r a t i o n ,
C-FAND e l a y f u n c t i o n 6 1 " F . . . 6 5 'F
8/7/2019 Samsung Refrigeration Familiarization
22/74
Disassembly I Assembly
18
Model number and specificationsare located on rear of cabinet.
Rear compartment cover is held inplace with six Phillips screws.
8/7/2019 Samsung Refrigeration Familiarization
23/74
19
The water valve must be removed toaccess the control board.
There are electrical noise filtersconnected in parallel with the watervalves.
8/7/2019 Samsung Refrigeration Familiarization
24/74
20
The compressor run capacitor andan AC line filter are located in thecontrol panel housing.The red input wire is L1 and theblack wire is neutral.
There are high voltages present onthe larger heat sink mounted to theboard.
8/7/2019 Samsung Refrigeration Familiarization
25/74
21
The board uses a high efficiency,high frequency power supply toconvert the line voltage to +12 and+5 volts DC.If this supply does not provide thecorrect DC voltages, the thermistorswill all sense temperatureincorrectly.
Each evaporator has it's own drainhose. Make sure that these hoses areinstalled with the slots near thebottom.
When installing drain tubes be surethe slot end is installed down andthe tube is secured into theembossment in the drain pan
8/7/2019 Samsung Refrigeration Familiarization
26/74
Condenser Fan Removal
22
Disconnect wiring harness.Remove screw and slide assemblytoward compressor to remove. Thefan blade is held onto the motorshaft using a friction fit wrap spring.Secure the motor shaft and twist offblade. Remove the screw securingthe motor to the bracket.
Compressor component routing.The rubber grommet on thedischarge tube is for noisereduction.
The compressor relay cover priesout and down from the compressorhousing.
8/7/2019 Samsung Refrigeration Familiarization
27/74
23
The compressor uses a PTC startingdevice.
The compressor harness and PTCcan be removed either separately oras an assembly.
8/7/2019 Samsung Refrigeration Familiarization
28/74
Drinking Water Circuit
24
Water system routing. The waterfilter is under supply pressure.There is a built-in shut off valve tostop flow if the filter is removed.All filter heads in unitsmanufactured before June 2003should be replaced.
8/7/2019 Samsung Refrigeration Familiarization
29/74
iIcemaker, auger motor and cubesolenoid locations.
25
8/7/2019 Samsung Refrigeration Familiarization
30/74
Icemaker overall view.
Icemaker components.The icemaker is serviced as acomplete assembly except for thesensing thermistor.
I GE N h \K E R K IT
G UIDE- IGE(Leve r to chI"{;!( I c e f u ll )
26
8/7/2019 Samsung Refrigeration Familiarization
31/74
The eject sensor is located on the bottom ofthe flex tray surrounded by a thermal barrier
The ice maker easily snaps apart for service
27
View of the bottom front of theicemaker. The icemaker uses a DCmotor to drive the flex action. Thetray will twist in the clockwisedirection to release the ice and thereversing motor will return the trayto the fill position in the counter-clockwise direction.
Completion of an ice cycle isdetermined by the temperature ofthe ice tray as sensed by thethermistor mounted to the bottom ofthe tray.
No tools are necessary todisassemble the icemakercomponents.
8/7/2019 Samsung Refrigeration Familiarization
32/74
28
Crusher blades are accessed byremoving the front housing from theauger bucket.
The cutter blades are retained by anylon nut. The nut and shaft haveright-hand threads.
8/7/2019 Samsung Refrigeration Familiarization
33/74
29
The freezer evaporator cover is heldin place with six screws.
Access to the freezer evaporator.
8/7/2019 Samsung Refrigeration Familiarization
34/74
Servicing the freezerevaporator thermal fuse
30
The thermal fuse (safety) is locatedon the lower right side of theevaporator.If this fuse is open, the appliancewill operate for four hours orcompressor run time, attempt thefirst defrost and fail to return tonormal operation.
The freezer evaporator thermistor ismounted in the lower right sectionof the evaporator coil.
The evaporator heaters are notreplaceable separate from theevaporator itself.The bimetal mounted in the top ofthe freezer evaporator in productmanufactured before June 2003. Thebimetal effectively bypasses theevaporator thermistor attemperatures below 23 degrees. Thebimetal opens at 54 degrees and thethermistor will provide actualevaporator temperature data to thesystem control.Production after June 2003 shouldnot include the bi-metal.
8/7/2019 Samsung Refrigeration Familiarization
35/74
3 1
There is a drain trough heater toprevent drain freeze-ups.
All plugs are color coded and keyedto prevent improper insertion.
A fill tube heater is used to preventicemaker fill tube freeze-ups.
8/7/2019 Samsung Refrigeration Familiarization
36/74
32
Access to the fill tube and heater.First, unplug the heater inside of thefreezer compartment. Remove theaccess cover on the top of therefrigerator to remove the fill tube.
8/7/2019 Samsung Refrigeration Familiarization
37/74
Remove screws securingevaporator cover and remove.The evaporator fan motor is
33
Three drawers. The upper drawerprovides for independenttemperature control. This is calledthe CoolS elect zone.One of the independent modes ofoperation is a thaw function thatuses the refrigerator defrost heaterto provide increased temperature fora set period of time, after the settime period elapses, the CoolS electzone returns to normal operation.The CoolSelect zone can alsoprovide for reduced temperature.
When used in the thaw mode, thedisplay will show the remainingtime set in the mode.The Quick Cool mode provides for100% cooling for up to 60 minutes.The display will show the remainingtime in that mode.The temperature selector providesfor independent temperature controlincluding a soft freeze at 23 degrees.
The fresh food evaporator uses aloop of the defrost heater as a drainpan defrost.The evaporator cover includes themounts for the evaporator fan andthe CoolS elect damper..
8/7/2019 Samsung Refrigeration Familiarization
38/74
Refrigerator evaporatortemperature sensor
Accessing Freezerand Refri erator
34
The fresh food evaporatorthermistor is clamped to the outlettube of the evaporator.
Connections are keyed to preventincorrect power routing.
Door switches are double pole,double throw switches. Low voltagecontacts are used to inform systemcontrol when a door is open. Highvoltage contacts are used to routepower to the interior lamps.
8/7/2019 Samsung Refrigeration Familiarization
39/74
35
Water filter and air distribution ductare mounted to the upper rear freshfood cabinet.The fresh food cabinet temperaturethermistor is located in the upperpotion of the air duct.
Filters remove in the unlockposition and are secured in thelocked position. The filter head hasa built in by-pass system to preventwater leakage when removed. Thefilter is under positive pressure. It isconnected directly to the incomingwater supply.
All pre 2003 filter housings shouldbe replaced for increased reliability.
8/7/2019 Samsung Refrigeration Familiarization
40/74
o00~. . . . . . .. . . . . . . .o:
36
To remove the dispenser facade,there is pone screw located in theroof of the dispenser opening. Thisscrew is located between thepaddles. Once the screw is removed,gently pry the facade out starting atthe bottom. There are slots forinserting a screwdriver to begin theremoval.
8/7/2019 Samsung Refrigeration Familiarization
41/74
37
8/7/2019 Samsung Refrigeration Familiarization
42/74
r-o o~. . . . . . .. . . . . . . .o:
Main PCB Power Supply
38
+12VDC and +5VDC supplies arecritical for proper operation. If the+ 12VDC is below +11.9VDC thereis a strong possibility thatcompartment temperatures will beabnormal. There is no repair of thepower supply, just replacement ofthe complete control board.
8/7/2019 Samsung Refrigeration Familiarization
43/74
PRP-PURPLES /B LU -S K Y B LU EWHT -WH I TEYEL -YELLOWBLK-BLACKW/BLK-WH ITE /BLACKW/RED-WHITE /REDW/BLU-WHITE/BLUE
CIRCUIT-DIAGRAMPANEL PCB MA IN PCB N A
RE D + BL KNO ISEF \ b l ER
BLK~ ~ BLK BLH I9 ?~B A N @BRNRED(13)# - - - - - - - - - - - - - - - - ,RE De @ RE D C N 1 0 (W H T ) IOR G @ @ ORG ~ DEFROS THEATER ,FYE L @ I VE L BAN I 1 THERf ' 9 t ~PN K M H ' PNK U - ~ t i ' ~ ~ w r ~ ~ ; ; : _ ~ = - = - = - = - = - ~ ~ " ~V '==+~=====m1ED BLKBL U < V BLU RED IG _ ! ) - F .f lRA IN HEAT ER EDP RP C D PRP WHT I D EF~ I,!IE AT ER ,R T HER fIO i\P =- -F US E,RGRY G R Y = 1W f IT@ I W f I T 0 1 ) 3~ - 7 > W - - -- I C f w j ~ ~ ~ i C = = = ~ : ;; ;; ;; 1S / BL U@ @ S/BLU C ! __C-"' p a r t m e a n s c on n e c t o r in R e f. u p p e r h in g eI W / B L K ~ BLK BLKI W / B L K ~W I B L K ~ HOME - BA R S IW
Y E L R E D D A9 9-0 02 35A R EV (O .1 )
39
BLU-BLUEBRN - BROWNRED-REDGRY-GRAYORG -ORANGEPNK-P INKE -EARTH
8/7/2019 Samsung Refrigeration Familiarization
44/74
~O J'o O JO J0 Ic Q jO J0 (/)C/) cO J? Q. (/)(/) Q j Q ju (5O J O J OJc (ij O J O J Q ;2 -
I ICO OJO J O J 0; 0; O J
(/) E 2 2 I"
8/7/2019 Samsung Refrigeration Familiarization
45/74
o0\Q)'"d. . . . . . .. . . . . . . .o:
.. Ice DispenseSwtch~ Fresh Food Door~ Arobient Thermistor
41
Thermistors are all the same sensorwith different harnesses attacheddepending on the mounting. It ispossible to either check theresistance of the sensor with theconnection unplugged, or check theDC voltage of the sensor.
8/7/2019 Samsung Refrigeration Familiarization
46/74
8/7/2019 Samsung Refrigeration Familiarization
47/74
Samsung Bottom Freezer
43
The bottom freezer incorporateselectronic control.
Typical compliment of interiorcomponents.
The icemaker is a manual fill andrelease.The freezer section uses pull-outdrawers for product storage.
8/7/2019 Samsung Refrigeration Familiarization
48/74
000\~. . . . . . .. . . . . . . .o:
44
Each compartment uses multiple airoutlets for even temperature control.
8/7/2019 Samsung Refrigeration Familiarization
49/74
R-FAN(CENTRIFUGAL TYPE)
R-EVAPORATOR
F-FAN(PROPELLER TYPE)
MOTOR
F-EVAPORATOR
OUTPUT AIR
RETURN AIR
45
8/7/2019 Samsung Refrigeration Familiarization
50/74
oo, . . . . . . . , There are two evaporators, one ineach compartment.This is a hot-walled refrigerator andrequires one inch of clearancearound the installation.The Sub-condenser empties into asteel hot-wall condenser that feeds acopper hot gas loop around the dooropemngs.The hot gas loop supplies the freshfood evaporator and the refrigerantflows to the freezer evaporatorbefore returning to the compressor.
46
8/7/2019 Samsung Refrigeration Familiarization
51/74
Connectercontactfailure-Shcrt-cjrcult
Table1_DisplaytableofselfdiilgnQsis
1 R -s en so r
REFRIGERATOR -Dounettorcontacttailure
3 Outer sense 'ConnectcrCOl1tactfailureES
-Connector ccntactIarlureF5 -Sbcrt-crcuit
47
To enter the self diagnosticsfunction, press the Power Freezeand Power cool buttons for fiveseconds.
8/7/2019 Samsung Refrigeration Familiarization
52/74
T ab le 1 . D is p la y ta b le o f s e lf d ia g no sis .
3
- C o nn ec to r c on ta ct fa ilu re- S h o r t -c ir c ui t
R - s e n s o rREFR IGERATOR
- C o nn ec to r c on ta ct fa ilu re - Su sp ec te d to b e b e lo w -58 O F5 - S h o r t -c ir c ui t - Su sp ec te d to b e o ve r 150 o f
2 R-de f r o s t e r REFR IGERATOR - C o nn ec to r c on ta ct fa ilu re - Su sp ec te d to b e b e lo w -58 O Fs e n s o r - S h o r t -c ir c ui t - Su sp ec te d to b e o ve r 150O Fd
FREEZERfSO ute r s e n - C o nn ec to r c on ta ct fa ilu re Sho r t- c i rc u i t - Su sp ec te d to b e b e lo w -58 O F- Su sp ec te d to b e o ve r 150 'FFREEZERF S
- C o nn ec to r c on ta ct fa ilu re- S h o r t -c ir c ui t
'S us pe cte d to b e b e lo w -58 'F-S u sp ec te d to b e o ve r 150O F4 F - s e n s o r
- Su sp ec te d to b e b e lo w -58 O F- Su sp ec te d to b e o ve r 150 'F
FREEZERdS
F -de f r o s t e rs e n s o r5
To enter the Operation Load Check,press the Power Freeze and Powercool buttons for three secondsfollowed by the Refrigerator Tempbutton within two seconds.
48
8/7/2019 Samsung Refrigeration Familiarization
53/74
During the operation load check, theilluminated digits will indicate thecurrently powered components aswell as indicate special modes ofoperation.The display LED listed refers to thetwo digit display for either therefrigerator or freezer temperature.Each display has a tens digit as wellas a ones digit. The tens digit is theleft-hand seven segment display (8)and the ones digit is the right-handseven segment (8) display.
Table 2. Display table of the presently operating parts.
1--+------+--------"-----+--...:...._----------1 R e ' . 6 . b u t t o n s c a n1--+=-c-~----,----+--------"-------+--...:...._----------1 a n d d i s p la y c i rc u i tr yIlb'19fb1--+~-----+-----~-----+~~~~~---,--~~-----1-'=f .'~fc10
Q)'"d. . . . . . .. . . . . . . .o:
Six screws must be removed toaccess the fresh food evaporator.
49
8/7/2019 Samsung Refrigeration Familiarization
54/74
00o, . . . . . . . ,
50
The fresh food evaporator fan is ablower wheel design.
The fresh food evaporator has anintegrated defrost heater loop.
The fresh food thermal fuse islocated on the upper left side of theevaporator coil.
8/7/2019 Samsung Refrigeration Familiarization
55/74
51
The fresh food evaporatorthermistor is located in the lowerleft hand comer of the evaporator.
The fresh food compartmentthermistor is located behind adecorative badge in the uppermiddle of the compartment.
8/7/2019 Samsung Refrigeration Familiarization
56/74
52
The light / thermistor housing mustbe removed to access the freezerevaporator.There are two screws securing thehousing to the top of thecompartment. The housing slidesforward to release.
The air duct snaps into place overthe evaporator cover. Pull gently toremove.
Two screws secure the evaporatorcover and fan mount.
8/7/2019 Samsung Refrigeration Familiarization
57/74
53
Propeller type fan with a tensionspring clamp.
View of freezer evaporator withcover removed
8/7/2019 Samsung Refrigeration Familiarization
58/74
54
The freezer evaporator thermal fuseis located on the lower left side ofthe evaporator.
The freezer evaporator thermistor islocated in the lower left comer ofthe evaporator.
The freezer compartment thermistoris located in the light housing.
8/7/2019 Samsung Refrigeration Familiarization
59/74
55
The temperature control panel issecured with three screws.
8/7/2019 Samsung Refrigeration Familiarization
60/74
56
To remove the door switchassembly, gently pry out on thehousing.
Door gaskets on the current bottomfreezer models are not replaceable.
8/7/2019 Samsung Refrigeration Familiarization
61/74
57
Make sure drain tubes are installedover the guides in the condensatepan.
8/7/2019 Samsung Refrigeration Familiarization
62/74
58
Condenser motor connection.
View of bottom freezer controlboard.
8/7/2019 Samsung Refrigeration Familiarization
63/74
59
8/7/2019 Samsung Refrigeration Familiarization
64/74
CIRCUIT-DIAGRAMM A IN P C B
F - T H E R M A L F U S E
BLU-BLUEBRN -BROWNE -EARTHGRY -GRAYORG -ORANGEPNK-P INKPRP-PURPLERED -REDS /B L U- SK Y B L UEWHT -WH I TEYEL - YE L LOWBLK -B LACKW/BLK-WHITE /BLACKW/RED-WHITE /RED
R . . ( ) ( X F tS J W ~ : ~ k t ~ ~ F - D R AI N H EA T E R D E F R O S T H E AT E R . FL (5\ WHT _ _ _ ! \ , DEFAOSTHEATBlRCN50 ,t-t--'YE"'L R--'J~~N,HE ATE R
C O MP C O OL IN G F A N1 B~ r0ft-~GR~Y--------------------------------~2 BRN . ' : 0 ' : : '3 REF ~ RROOM LAM P~ ~~GDft-~WS~L~K-----------~rt~-------------------4; : ~ ~ : : t ORG R-R~M}-F-m------------------_48 PRP BLU F-RO~ FAN9 GR Y M}------------------------1o WH T r.i\ PN K F-RO ~ LAM P;;: ;: RED &~----------------------1
: mffi'I.':o'::'(nlt-t~~--------------------------------~
R - TH E R M A L r u SE~
' 1 *- DA99-00232A REV(O.1)The bottom freezer uses a moresimplified control board. All loadsare 120VAC components.
60
8/7/2019 Samsung Refrigeration Familiarization
65/74
ill1 iiill illc Iro 1 iiu, 1 i5 illC 0.. 0.. 0 Iro E '$u, ro c 1 i5ro >0.. 0.. ....J UJ ro Cl eE u,ro -0 -0 -0 ill 0ro > 0 0 ill 0 Cl in....J UJ 0 0 en 0 (fJill ill u, u, ~c u, ill illill o_
N N _c s: -0 s: Nill ill in (fJ - s c en ill Eill ill ill ill Q) 0 ill ill 0~ l i : : l i : : l i : : l i : : l i : : l i : :....J :z U uIDDDDDDDDDI IDDDDDDDDDI---IIII III---
61
ill 0iij 00. . . 0e 0c : 0o 0U 0~0.;::0~ D0..0E 0~ 0~ 0
~Q)EEu:cC1 lt=EoU :
Freezer ThermistorFresh Food ThermistorFreezer Defrost ThermistorFF Defrost Therm istor
Ambient Thermistor
9VAC
13VAC
8/7/2019 Samsung Refrigeration Familiarization
66/74
Thermistors are all the same sensorwith different harnesses attacheddepending on the mounting. It ispossible to either check theresistance of the sensor with theconnection unplugged, or check theDC voltage of the sensor.On the bottom freezer refrigeratorthere is no offset adjustment of thethermistors.
Thermistor Spec Chart.~ ~
-43.6 98.870 4.541-41.8 93.700 4.518-40.0 88.850 4.494-38.2 84.150 4.469-36.4 79.800 4.443-34.6 75.670 4.416-32.8 71.800 4.389-31.0 68.150 4.360-29.2 64.710 4.331-27.4 61.480 4.301-25.6 58.430 4.269-23.8 55.550 4.237-220 52.840 4.204-20.2 50.230 4.170-18.4 47.770 4.134-16.6 45.450 4.098-14.8 43.260 4.061-13.0 41.190 4.023-11.2 39.240 3.985-9.4 37.390 3.945-7.6 35.650 3.905-5.8 33.990 3.863-4.0 32.430 3.822-2.2 30.920 3.778-0.4 29.500 3.7341.4 28.140 3.6893.2 26.870 3.6445.0 25.650 3.5976.8 24.510 3.5518.6 23.420 3.50410.4 22390 3.456
12.2 21.410 3.40814.0 20.480 3.36015.8 19.580 3.31017.6 18.730 3.26019.4 17.920 3.20921.2 17.160 3.15923.0 16.430 3.10824.8 15.740 3.05726.6 15.080 3.00628.4 14.450 2.95530.2 13.860 2.90432.0 13.290 2.85333.8 12.740 2.80135.6 12.220 2.75037.4 11.720 2.69839.2 11.250 2.64741.0 10.800 2.59642.8 10.370 2.54544.6 9.959 2.49546.4 9.569 2.44548.2 9.195 2.39550.0 8.839 2.34651.8 8.494 2.29653.6 8.166 2.24855.4 7.852 2.19957.2 7.552 2.15159.0 7.266 2.10460.8 6.992 2.05762.6 6.731 2.01264.4 6.481 1.96666.2 6.242 1.922
68.0 6.013 1.87869.8 5.792 1.83471.6 5.581 1.79173.4 5.379 1.74975.2 5.185 1.70777.0 5.000 1.66778.8 4.821 1.62680.6 4.650 1.58782.4 4.487 1.54984.2 4.329 1.51186.0 4.179 1.47487.8 4.033 1.43789.6 3.894 1.40191.4 3.760 1.36693.2 3.631 1.33295.0 3.508 1.29896.8 3.390 1.26698.6 3.276 1.234100.4 3.167 1.203102.2 3.062 1.172104.0 2.962 1.143105.8 2.864 1.113107.6 2.770 1.085109.4 2.680 1.057111.2 2.593 1.030113.0 2.510 1.003114.8 2.429 0.977116.6 2.352 0.952118.4 2.278 0.928120.2 2.206 0.904
62
8/7/2019 Samsung Refrigeration Familiarization
67/74
0'7 '", . . . . . . . , '" sQ)'"d. . . . . . .. . . . . . . .o:
63
The fresh food and freezerthermistors can be adjusted byclipping out diodes on the mainboard. It is suggested that thisapproach not be used. Either replacethe thermistor that is out of range orreplace the main control boarddepending on the fault condition.
There is a low voltage transformerthat supplies 9VAC and 13VAC.The test switch will initiate a defrostcycle. The first press will initiate aforced pull-down. The second timeit is pressed, the fresh food sectiondefrosts independent of the freezersection. Pressing a third time willinitiate a combined fresh food andfreezer defrost. Pressing the testbutton again will cancel the forceddefrost.
8/7/2019 Samsung Refrigeration Familiarization
68/74
. 1 1Condenser Fan ~Freezer Evap Fan ~FF Evap Fan ~
(/)Q ;"" 0 1i iQ)0 Ic Q ;Q)"0 (/)C/) cQ)' Q. (/)(/) Q ; Q ;u is1 ii 1 ii 1i ic < if Q) Q) Q ;2 - I IIII U i U i 1i iQ) Q) Q)g J E 0 0 I""0 '$ '$""0 0 Q) 0 U i0 Q i I 0 0 00 c 0 '$c Q) tt: _y- E 0Q) (5 "0 Q) c (/) g 1i i 0"0 ~ (/)2: C/) " S Q) Q ;C/) s: ~ 0. c Q jQ) Q ; LL o Q ; 5 .Ql N..Q OJ ~ " S E Q i '$ Q)~ ~ ~ Q) Q) 0 ~
8/7/2019 Samsung Refrigeration Familiarization
69/74
-oIr--: : : : : >oa:-o
~ Q) - -oUJ C) , . . . .r::< C : : : : > :.E 0UJ _JUJ_J ~ -: : : : > ~ e : : ~ >_J UJUJUJ~ r l l U J : S : f-!:::f- c.. UJ::::l a ::c . . . ~ f - 6 I : : : C I 0 5~ c n I : : : l < c : s : ~ : S : a:: c . . . ~ : ? ; = ~ ~ ~ o : : : : ' .!: LOc : . _ J f - ~ ~ ~ ~ a : l ~ C')g:~~~~::: C\JQ) 0r:: 0r:: I8 0')U J en 0')Z C J r:: roU J ~ ~ ~ ~ Q) ClE: : : : > c:C:Z:::C 1 8_JC:UJ O-f-[]JrllC:CJ. c...c: c..~ z 6 > - C J ~ L i S 0_JC:UJC:C:Z.[]J[]JC:CJOc...UJ ..r:::ro(..)*" '"_j
8/7/2019 Samsung Refrigeration Familiarization
70/74
ill1 iiill illc Iro 1 iiu, 1 i5 illC 0.. 0.. 0 Iro E '$u, ro c 1 i5ro >0.. 0.. ....J UJ ro Cl eE u,ro -0 -0 -0 ill 0ro > 0 0 ill 0 Cl in....J UJ 0 0 en 0 (fJill ill u, u, ~c u, ill illill o_
N N _c s: -0 s: Nill ill in (fJ - s c en ill Eill ill ill ill Q) 0 ill ill 0~ l i : : l i : : l i : : l i : : l i : : l i : :....J :z U uIDDDDDDDDDI IDDDDDDDDDI---IIII III---
66
ill 0iij 00. . . 0e 0c : 0o 0U 0~0.;::0~ D0..0E 0~ 0~ 0
~Q)EEu:cC1 lt=EoU :
Freezer ThermistorFresh Food ThermistorFreezer Defrost ThermistorFF Defrost Therm istor
Ambient Thermistor
9VAC
13VAC
8/7/2019 Samsung Refrigeration Familiarization
71/74
z ~oa:-o ~~ C !J : : : : l " " CII: _J Z W0 C O n, II:
0III ~f. (z ~:2' z0
o.._>wa:C \JMC \JooI0>0>o
ID~--'UJ~
a: e i u . . . II:0 ~ien (IJ 0 II:Z iii (IJ 8w zen (IJ w::;: : : ; : (IJ en c~~ lLlL d: E E II:u,
W W0 0
67
8/7/2019 Samsung Refrigeration Familiarization
72/74
8/7/2019 Samsung Refrigeration Familiarization
73/74
8/7/2019 Samsung Refrigeration Familiarization
74/74
Be Aware, Be AlertAlways work safely.On the Job, On the Road, In the HomeEvery Time, All the Time
Top Related