Download - RENEWABLE ENERGY SYSTEM - GezelmanPE · 3 8 - 16 x 3 4 hex head bolt 3/8-16 flange bolt pv module serrated l roof mount 2" x #14 " crs mid clamp water proofing exist. roof deck solar

Transcript
Page 1: RENEWABLE ENERGY SYSTEM - GezelmanPE · 3 8 - 16 x 3 4 hex head bolt 3/8-16 flange bolt pv module serrated l roof mount 2" x #14 " crs mid clamp water proofing exist. roof deck solar

38 - 16 X 34 HEX HEAD BOLT3/8-16 FLANGE BOLT

PV MODULE

SERRATED LROOF MOUNT

2" X #14 " CRS

MID CLAMP

WATER PROOFING

EXIST. ROOF DECK

SOLARMOUNT RAIL

EXISTINGPURLINS

EXIST. INSULATION

PZ2 = 48"

PZ2 = 48"

RIDGE

EAVE

GA

BLE

GA

BLE

SK

YLI

GH

T

SK

YLI

GH

T

SK

YLI

GH

T

4'-0"

PZ3

PZ3

PZ3

PZ3

PZ2PZ2

PZ1

+/- 56'-0"V.I.F.4'-0"

DN

4/1

2

UNIRAC RAIL (TYP)

APPROVED ALTERNATIVE MOUNTING AREA FOR UPPER ROW OF 10 MODULES (CONTRACTORS OPTION)

4'-

0"

4'-

0"

4'-

0"

PURLINS, 48 C-C (SAME ON SOUTH SLOPE)

SK

YLI

GH

T

SK

YLI

GH

T

SK

YLI

GH

T

#15091, 1 STORY HANGAR

METAL ROOF SLOPE 4/12

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN: CHECKED:SB AG

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

KA

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E

AC

CE

SS

ED

AT

: W

WW

.GE

ZE

LMA

NP

E.C

OM

/PV

/0

24

9P

.AS

.Sto

cks_

FtM

yers

_F

L.d

wg

REVISIONS:

01SCALE: N.T.S. IMAGERY MAY NOT CORRECTLY INDICATE CURRENT POTENTIAL SHADING OF PROPERTY.

PARCEL - (AHJ PROPERTY APPRAISER)02

SCALE: 3" = 1'-0"

ROOF MOUNTING DETAIL

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECTMAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.

04SCALE: VARIES

SOLAR RACKING - UNIRAC

CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC

C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC

C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF

THIS PLAN IS ONLINE FOR REVIEW @

WWW.GEZELMANPE.COM/PV/0249P.AS.STOCKS_FTMYERS_FL.PDF

CO

NT

AC

T D

ES

IGN

TE

AM

@

ww

w.G

eze

lma

nP

E.c

om

ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549

PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE CURRENTFBC AND NATIONAL ELECTRICAL CODE

INS

TA

LLA

TIO

N O

F A

RO

OF

MO

UN

T

RE

NE

WA

BLE

EN

ER

GY

SY

ST

EM

TH

E

ST

OC

KS

RE

SID

EN

CE

SPEED: 160 MPH

EXPOSURE: B

RISK CATEGORY: II

UPLIFT(PSF) : PZ1-21.1, PZ2-39.8 PZ3-N/A

CO

DE

VE

RIF

Y

MODULE# LG250S1C-G3 FSEC: LG12-NT90-0106

DESIGNED PER: ASCE 7-10, 2010 NEC, FBC 2010

07SCALE: 1/8" = 1'-0"

ROOF LAYOUT DRAWING

WIN

DCONTRACTOR:

LIC# CVC05664 LIC#CWC043077

2431 CRYSTAL DRIVEFT. MYERS, FL 33907

PH. 239.939.7446FAX: 239.939.2946

03SCALE: NTS

ACTUAL SITE PHOTOS

AHJ: LEE COUNTY, PARCEL ID# 15-44-26-03-00000.0040

15

09

1 F

LIG

HT

LIN

E C

T

FO

RT

MY

ER

S F

L 3

39

05

STRUCTURAL LOAD FROM EQUIP < 4PSF

PRESSURE ZONES: HTTP://WWW.GEZELMANPE.COM/REFERENCE/WIND_US.PDF

06SCALE: NTS

ELECTRICAL COMPONENT SPECIFICATIONS

PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES:

THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION)

AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN AS STATED ON THE DRAWING. ACTIVE

HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM

DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION

HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTOVOLTAIC (SOLAR

ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE SOLAR MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED.

THE HOLD DOWN ANCHORS SHALL BE SOLAR RACKING OEM L-FEET ATTACHED INTO ROOF PURLINS THRU NOA/PCM ROOFING CAULK BY

GASKETED ROOFING SCREWS (MINIMUM 2-INCH, #14 DIAMETER) CORROSION RESISTANT STEEL. SOLAR RACKING SHALL RUN PERPENDICULAR

TO ROOF PURLINS. L-FEET SHALL ATTACH SOLAR RACKING INTO EACH PURLIN CROSSED.

PRESSURE ZONE (PZ) #2 WIDTH IS 4-FT. PV ARRAY TO BE INSTALLED PRIMARILY WITHIN PZ1. THERE SHALL BE TWO PIECES OF SPECIFIED

RACKING UNDER EACH PV MODULE. THE PV MODULES SHALL BE INSTALLED IN THE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV

MODULES IN EACH STRING AS DEPICTED IN THE ELECTRICAL LAYOUT OF THIS SUBMITTAL.

THERE SHALL BE FOUR CLAMPS HOLDING EACH MODULE TO THE RAILS. THESE SHALL BE PAIRED OPPOSITES. ADJACENT MODULES MAY SHARE

CLAMPS. PV MODULES MAY BE ORIENTED “LANDSCAPE” OR “PORTRAIT” AT THE CONTRACTOR'S OPTION.

WATER-PROOFING: A GENEROUS PUDDLE OF FLORIDA NOA/PCA LISTED ROOFING SEALANT BETWEEN RACK MOUNTING “FEET” AND ROOF

COVERING AT EACH ATTACHMENT POINT IS ADEQUATE. HOWEVER, CONTRACTOR IS FREE (SUBJECT TO AHJ) TO SELECT ALTERNATE

WATERPROOFING MEANS AND METHODS FROM NRCA (NATIONAL ROOFING CONTRACTORS ASSOCIATION) ROOFING & WATERPROOFING

MANUAL, OR OEM INSTALLATION DETAILS, OR OTHER APPROPRIATE SOURCES.

ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OF INSTALLATION AND

AS THE SYSTEM “AGES”.

ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS.

ENGINEER OF RECORD AVAILABLE FOR QUESTIONS: [email protected] OR 813 909 1956

10/28/12

OWNER:

15151 FLIGHTLINE CT, FORT MYERS FL 33905

SCHMIDT RICHARD + PEGGY A

04

05SCALE: NTS , THESE PICTURES ARE TYPICALL INSTALLATIONS

SAMPLE INSTALLATION PHOTOS

DETAILS MAY VARY - CURRENT OEM INSTRUCTIONS PREVAIL

HTTP://WWW.UNIRAC.COM/TECHNICAL-SUPPORT/SOLARMOUNT/INSTALL.PHP

UNIRAC CODE COMPLIANT LETTER - FLORIDA:

INSTALLATION LOCATION

Siggi
Snapshot
Siggi
Snapshot
Page 2: RENEWABLE ENERGY SYSTEM - GezelmanPE · 3 8 - 16 x 3 4 hex head bolt 3/8-16 flange bolt pv module serrated l roof mount 2" x #14 " crs mid clamp water proofing exist. roof deck solar