8. Well Name and No.OSPREY 30-7
2. Name of Operator Contact: STEVEN VEALBRIDGECREEK RESOURCES COLO ElhCiil: [email protected]
9. API Well No.30-045-35736-00-S1
3a. Address405 URBAN STREET, SUITE 400LAKEWOOD, CO 80228
3b. Phone No. (include area code)Ph: 303-945-2637Fx: 303-945-2649
10. Field and Pool, or ExploratoryVERDE GALLUP
4. Location of Well (Footage, Sec., T„ R,, M, or Survey Description)
Sec 30 T31N R14W SWNE 1933FNL 1939FEL36.873895 N Lat, 108.348200 W Lon
11. County or Parish, and State
SAN JUAN COUNTY, NM
12. CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA
TYPE OF SUBMISSION TYPE OF ACTION
□ Notice of Intent□ Acidize □ Deepen □ Production (Start/Resume) □ Water Shut-Off
□ Alter Casing □ Fracture Treat □ Reclamation □ Well IntegrityB Subsequent Report □ Casing Repair □ New Construction □ Recomplete B Other
□ Final Abandonment Notice
_________________
□ Change Plans □ Plug and Abandon □ Temporarily AbandonWorkover Operations
□ Convert to Injection □ Plug Back □ Water Disposal
13. Describe Proposed or Completed Operation (clearly state all pertinent details, including estimated starting date of any proposed work and approximate duration thereof. If the proposal is to deepen directionally or recomplete horizontally, give subsurface locations and measured and true vertical depths of all pertinent markers and zones. Attach the Bond under which the work will be performed or provide the Bond No. on file with BLM/B1A. Required subsequent reports shall be filed within 30 daysfollowing completion of the involved operations. If the operation results in a multiple completion or recompletion in a new interval, a Form 3160-4 shall be filed once testing has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have been completed, and the operator has determined that the site is ready for final inspection.)
The following is the completed worker procedure for the July 26, 2016 worker of the Osprey 30-7:1. Mobilized worker rig onto Osprey 30-7 and rigged up.2. Pulled rods and pump and stand back.3. Unseated packer at 4854 feet KB and pulled 2-3/8” tubing.4. Relocated packer at 4351 feet KB and read 2-3/8" tubing. n5. Reran pump and rods. . cvV^U “6. Demobilized rig and returned well to pumping operations^r twl
A wellbore diagram is attached.°'vC
ACCEPTED FOR RECORD
By:Tres
SEP 0 6 2016
Jsnies'Fie-ield OfficeBureau of Land Management
14. I hereby certify that the foregoing is true and correctElectronic Submission #349458 verifie
For BRIDGECREEK RESOURCES Committed to AFMSS for processing by BAR
Name (Printed/Typed) STEVEN VEAL
i by the BLM Well Information SystemCOLO LLC, sent to the Durango
3ARA TELECKY on 09/02/2016 (16TA0928SE)
Title PRESIDENT
Signature (Electronic Submission) Date 08/29/2016
THIS SPACE FOR FEDERAL OR STATE OFFICE USE
Approved By Title Date
Conditions of approval, if any, are attached. Approval of this notice does not warrant or certify that the applicant holds legal or equitable title to those rights in the subject lease which would entitle the applicant to conduct operations thereon. Office
Title 18 U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any department or agency of the United States any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.
BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED
NMOCD<N
BRIDGECREEK RESOURCES (PALOMAR NATURAL RESOURCES)WELL NAME
HELDOsprey 30-7Verde Gallup
SEC., TOWN., RANGE: S34T31NR14WSurface: 1933* FNL, 1939' FEL At Total Depth: 180' FNL. 1980' FEL
LOCATION San Juan County. NM SURFACE LAT (NAD27): 36.8737673* N
PALOMAR API#AFE NUMBER
30-045-35736VG27DC
SURFACE LONG (NAD27): 108.3477170* WKB: 5583
natural resources REVISION DATElift 4/21)1507/26/2016 UPDATED BY: Yancey
Date: Into:11/24/15 Release rig & equip, to PF 19-2917 <B 10:00 hours11/29/15 WO rig moved from KS to Osprey: drill out DV tool, tag Q 2999’
Frac GH; screen out, unable to continue to next stages; SDFN12/5/15 RU WO rig, dean out sand down to TD;12/6/15 HAL MIRU to continue to frac next stages; finish stages
MIRU MVCI flowback crews12/8/15 RU AWS rig to drill out plugs and to dean out wefl w/ air12/10/15 RDMO AWS rig; set tbg string end rod string as shown in WBD12/17/15 Finished building faculties; PU running at 8 SPM
Fluid LevelsDate Info1/6/16 Fluid level at 1248' above pump intake
Hole Size12-1/4" Dia Dried to 360' KBSurface Casing:9-5/8" 36# J55 STC @ 348.62' KBCement to surface24 bbls of good cmt to surface
r^-4cmt DV stag! Tool g 2999' KB
Hole Size
7-7nr bit <ftaDrS>d to <990' KB
Intermediate Casing:
5-1/2*17# N80 LTC Q 4982' KB
Camsnt to surface
29 bbls of good cmt to surface
Top of packer @ 4351' KB
SN@4921'KB
2-3/8" Tbg.EOT @ 4925' KB
PBTD: 4972' KB
TD: 4,990' KB
Completion Detail Plug aStage Top (MD)
feetBtm (MD)
feetTop (TVD)
feetBtm (TVD)
feetNet Int (MD)
feetSizeinch
SPF#
Phasedeg
Holes#
Status
4.900 4,951 4,891 4,942 25 0.4 2 90 50 open4,546 4,693 4,537 4,684 24 0.4 2 90 48 open4,413 4,494 4,405 4,486 24 0.4 2 90 48 open4.263 4,342 4,255 4,334 20 0.4 2 90 40 open4.074 4,208 4,066 4,200 24 0.4 2 90 48 open
0.4 2 90 00.4 2 90 0
Blank (MD)
405
231268
T20r
8392
BD PressStage 1 Stage 2 Stage 3 Stage 4 Stage 5 Stage 6
PS'3,741.0 2,580.0 985.8 749.0 328.0BD Rate 7.0 2.0 10.0 35.7 36.0 bpm
AvgP 3,068.0 4,065.0 2,031.0 2,045.0 1,862.0 psiMax P 5,832.0 5,364.0 2,098.0 2.213.0 5,961.0 psi
Avg BH Rate 37.8 31.5 45.2 49.0 49.7 bpmMax BH Rate 50.7 37.7 52.0 50.4 60.7 bpm
20/40 67,100.0 0.0 71,660.0 104,500 0 47,100.0 lbs40/70 7,950.0 7,200.0 7,900.0 7,950.0 8,260.0 lbs
Total Clean 817.0 548.0 784.0 941.0 543.0 bblTotal Slurry 1,489.0 623.0 1,755.0 2,123.0 1,240.0 bbl
Production Equipment Detail Production Tubing:1 ea. Retrievable packer 3.7*1 ea. Perf d sub 4.1'1 ea. SN 1.1' set 9 4821' KB 4914' of 2-3/8" tbg string
Rod and Pump Assembly1 guided rod for every 3 unguided rods, top -1500 ft guided
2" x 1-1/2" X14' RWAC insert pump (104" sq