PHONE 531-5261 0 LE111iRF TRANSMITTAL
fTt WILSON OKAMOTO & ASSOCIATES, INC. ENGINEERS, ARCHITECTS AND PLANNERS
P.O. BOX 3530 HONOLULU, HAWAII 96811
TO: Division of Water and Land Development P.O. Box 373 Honolulu, Hawaii 96809
GENTLEMEN:
WE ARE SENDING YOU ~ Attached
0 Shop drawings 0 Prints
0 Copy of letter 0 Change order
DATE: April 241 1989 JOB NO.: 2881-01
ATIENTION: Mr_ Ed Sakoda
RE: Grand Hyatt Wailea Hotel
Wailea, Maui, Hawaii
- Proposed Saltwater Lagoons -
0 Under separate cover
0 Plans 0 Samples o Specifications
o Others
Permit Application for Test Well with Filing Fee
THESE ARE TRANSMITTED as checked below:
fQI For approval o No exceptions taken
o For your use o Note markings
o As requested o Returned
o For review & comment
•• rn 3: rnJ>o C)
o ~ubmit-lli.iI.l· ·L.-__ ,copies For review
o Submit-,----.,. ____ copies " for distribution
o Return _____ corrected prints
REMARKS_~I~f~y~o~u~h~a~v~e~a~n~y~q~u=e=s~t=i=o~n=sL'~p=l=e=a=s=e-=c=a=l=l_A~l=a~n~S=uw~a-=o~f_W~i~l~so~n~O~k~p=m=o~t~o~ _____ __
& Associates at 531-5261.
Alan Suwa, Planner
SIGNED:---\:t~/t'-!o/.£...~_:k£~:'=~"';olo~~~Ioa~-""""'=--___ _
COpy TO: _________________________ __
AS/to
Speediply· MCf. Patented IF ENCLOSURES ARE NOT AS NOTED, KINDLY NOTIFY US AT ONCE. ff] ---- .,,"---------------
Rev. 12188 rNOFWATERrUR/A~NT ~ DATE: '" Y~ FILE IN: _______ _
PLEASE: REMARKS:
FROM:
TO: INITIAL:
_ --:-:::::;-~GOMORI
/' £I?Lum _ G. Matsumoto
__ G. Akita __ L. Chang __ Y. Shiroma
/' __ E. Sakoda r:;1; ;'"
__ D. Nakano __ W. Rozeboom __ P. Haraguchi __ S. Samuels __ R. Chung __ T. Kam __ A. Monden __ H. Young __ R. Suzuki __ N. Kaneshiro __ T. Nakama
_See Me _~_T Take Action By __
Route to Your Branch Review & Comment
__ Draft Reply __ __ Acknowledge Receipt __ Xerox __ copies
File Mail For Information
S. Kokubun ___ D. Hamada ___ L. Nanbu ___ F. Ching
C-~4 HU,?
3 IIV- fTO HIM ~
~l~M1 61(. r
o o State of Hawaii
COMMISSION ON WATER RESOURCE MANAGEMENT Department of Land and Natural Resources
Division of Water Resource Management
APPLICATION FOR
x WELL CONSTRUCTION PERMIT (TEST WELL)
PUMP INSTALLATION PERMIT
tRSTRUCTtONs: Pl .... prtnt 01' type .nd .. nd completed .ppdcafton With .tt.ehment. to the blit.fon of W.f ... and Land ... D.v.lopment, P.O. Box 313, Honolulu, H •• ait "109. Applle.tion mu.t be .ccompanied by • non-r.fund.bl. nun, fet! of $25.00
pAy.ble to the Department of Land and N.tu1'ai aelOure... (FlUn, t .. waiv.d tor 1O".mm.nt 'Ienete •. ) If nec •••• ry, phon. 541-7543. HydroloU'GeolorY Section for ..... tance.
1 • WELL LOCATION
Island Maui --------89
Tax Map Key 2-1-08: 91 &-5-9'
Address 3850 Wailea Alanui Drive, Kihei, Maui, Hawaii 96752
(Attach a USGS map (scale 1"=2000') and property tax map showing well location referenced to established property boundaries.)
2. WELL OWNER LANDOWNER
Firm Name Grand Wailea Co.
Contact Person Denis Shiu c/o.
Address Wilson Okamoto & Assoc.
1150 S. King St., Honolulu, HI 96814
Phone 531-5261 --~~~~--------
TSA International, Limited & Firm Name Kumagai Gumi Co., Ltd.
----~--------------~--Contact Person Mr. Hideki Hayashi Address 1 585 Kapiolani Blvd., Suite 1600
Honolulu, Hawaii 96814
Phone 942-2131
3. PROPOSED CONTRACTOR FOR: QVWell Drilling DPump Installation
Name Paul Kuchler - PR Drilling Co., Inc. Phone 487-9969
Address 98-710A Kuahao Place Contractor's License No. __ .:.:C.;;;.-,,-96~2~7,--____ _
Pearl City, HI 96782
4. PROPOSED WORK
5.
u:J Drill Nell Well (TEST) 0 Deepen 0 Redrill CJ Alter r:::J Seal . 0 Abandon D Install New Pump D Replace Pump 0 Modify Pump
(Briefly describe the proposed work and fill in the diagram on the back of this form.)
PROPOSED USE
OMunicipal (including hotels, stores, etc.) ODomestic (individual, noncommercial water systems)
o MiUtary o Industrial
6.
OIrrigation (specify) ______ _ i2QOther (specify) Salinity Test for salt water supply for
300-500 gallons per ~ hotel ponds and PROPOSED AMOUNT OF WITHDRAWAL ~~~~---- mlnute. inJ'ection capacity. Temp.
Suction 7. PROPOSED PUMP INFORMATION
Pump Type: DVertical Turbine lE~~ Motor: ~Diesel DGas OElectric:
o Centrifugal Rated Horsepower --------Rated Pump Capacity 300-500 gallons per minute (gpm)
* * * * * • • • • • • • • * • • • • • • * • • • * • • * * • • • * • • • • * • • • • • * * * * • • * * TSA International, Limited &
Well Owner Landowner (
Signature ...• Signature Date ~...IALlIlLlO~=::;"--~~b~~---- 'Date ___ .....:....o\--____ _
For OfficiaL C e onLy: FieLd Checked By ______ _ Latitude -------- HydroLogic Unit _______ _ Date _____________________ __ Longi tude ____ _ State WeLL No. Lfl26 -CJIM
) -----------------_.,",.
...
Briefly describe the proposed work:
Proposed work includes drilling of approx. 100 foot well for testing of salt
water quality and q].lantity for hotel water feature uses, also to verify
injection capacity in area for draining water features.
Elevation at top 12+ ft .•
Cement Grout 10 ft.
H?le5~ Dla. in.
Total
of casing mSl.~
Depth 100 ft. --..
Rock Packing N.A. ft.
PROPOSED SECTION OF WELL (TEST WELL)
Ground Elev. 10+ ft., msl-----~~~---------------
Solid Casing: Material PVC or B1Si!.s;<k ;eLl:: Length as reguired for t~~t ft.
Diameter in.
Wall thickness in.
YcaSing: I IPerforated
I Material ~a!.::s!....;!;r..::;e;,:;jg.!:!u.=.ir;.;e::.:d~f;;,.::o~r~t~e~s.!::;t __ _ Length __________ ft.
I IScreen
I I
Diameter __ 1'--_____ in.
Wall thickness _______________ in.
Openings sq. in.j L. F.
~openHOle: Length Approx. 30-40'
4" Diameter ____________ in.
-Approximate elevation at time of ruing application. Final elevation (msl) by a surveyor licensed by the State must be submitted at start of construction.
o o
,. ."
PROJECT LOCATION
WAILEA POINT _........,.....:... CONDOMINIUM DEVELOPMENT,
/ ,,>0
'E ° to I X, sing .----:;:-+-If.-~.., Wailea ' Alanui Drive \
, /' *
I
o 1000 2000 i I SCALE IN FEET
Fig. 1 Location Map
GRAND HYATT WAILEA
prep~red by:
WILSON OKAMOTO & ASSOCIATES, INC.
,',
~ ,- ~
... : ;S ~ "{
~ '. ~
.... \)
~ " ~
... ~ ......
0. 0
O· ~} t
t 0
TMK: 2-1-08 1n = 10001,
" \V/~/~eA .', ~
-.
~ ..
Rev. 12/88 I D~N OF WATER RESOURCE ~Alf'N1" :rs DATE: ~ ,¥WLElN: £flU-Of M FROM:
TO: INITIAL: PLEASE: REMARKS:
_ . ~TAGOMORI
L 'iK-~.~um ~ G. Matsumoto
__ G. Akita __ L. Chang __ Y. Shiroma
~. 4-.. ". E. Sakoda _ --UJ- D. Nakano
__ W. Rozeboom __ P. Haraguchi __ S. Samuels __ R. Chung __ T.Kam __ A. Monden __ H. Young __ R. Suzuki
See Me _ Take Action By __
Route to Your Branch Review & Comment
_ Draft Reply _ _ Acknowledge Receipt _ Xerox __ copies
File . Mail
7/For Information
_ __ S. Kokubun ___ D. Hamada ___ L. Nanbu ___ F. Ching
---r- N. Kaneshiro L -/ _L_" ;f_;J_~_a _a_OJ(~
--- . ... -
o o . .
o o
WILSON
OKAMOTO 2645-06 & ASSOCIATES August 17, 1989
ENGINEERS
Department of Water and Land Development P. O. Box 373 Honolulu, Hawaii 96809
Attention: Geology-Hydrology Section
ARCH ITECTS Subject: Well Construction Permit for Grand Hyatt Wailea Test Well Well No. 4126-01M
PLANNERS
1150 SOUTH KING STREET
HONOLULU, HAWAII 96814
PHONE: (808) 531-5261
Mailing address: P. O. Box 3530
Honolulu, Hawaii 96811
Wail ea, Maui
Gentlemen:
In accordance with the conditions of the subject permit issued on May 24, 1989, we are transmitting the attached report on the results and completion of the test well.
Should you have any questions, please call me at 531-5261.
Sincerely,
WILSON OKAMOTO & ASSOCIATES, INC.
~~~ Alan M. Suwa, Planner
cc: Grand Wailea Company Steve Bowles Keith Kawamura, HFA
o ISLAND RESOURCES, LTD. Resource Management with Imagination
Water. Land. Energy
o
STEPHEN P. BOWLES President t. '1.
-Telep;hone (8081 eS5-4759
The test completed August 5, feet and performed in figure
TEST BORING FOR GRAND HYATT
SALT WATER SUPPLY/DISCHARGE
'. ": ~ ~
!J ~~_~
, f; .: ,J
boring was constructed starting on June 13, 1989 and in August 7, 1989. The final test was conducted on 1989 with the temporary casing set at a depth of 80 open hole to 120 feet. Water quality tests were
as drilling progressed and the results are summarized 1.
Upon final cleaning and testing, a 4 inch diameter PVC casing was installed as shown in figure 2. As indicated in figure 1, the ocean quality water was not struck until a depth of 80 feet. A complete chemical analysis of the water at that depth is enclosed and is nearly 100% sea water.
The pumping test of August 5, indicated a specific capacity of 73 gpm/ft. of drawdown (138 gpm with a draw down of 1.9 feet). This would result in a draw down of about 3 feet at a pumping rate of 200 gpm (the estimated rate needed for make up water). An adequate supply of salt water can be developed on site below elevation minus 70 feet. Attached is the driller's log.
~~ Stephen P. Bowles
P.O. Box 1656. Kamuela, Hawaii 96743
~~~ H1'k-(-( I WAILeA
5~L-r WA1t.~i,<pLo~·'lott W~llr 0
~ 3 ~ 8
pE-p-~n-\. ~El..ovJ q«.olJ t!f) \1\) fur () T -
-----.----f~----· -.. " .. & 0 .... ,
~m -----I
10.0' I
110,0'
--t4-Of-iO Sq4...
F16tU~-, 2.
.rL4N fOR. 6· tY!. [...Oe-A110N
fJfJ-r 7V ~Aie
,,,, . '~-!..~
i JUL F.~ '89 18:::) ~~ILSUll UI.HI'll'I'-' H:,;:>'," .... OUCi :,,=,c,_,c,~,::, . '; .......... ··0·· ........ : TO 536'5623
o
:AECOS
r ....
'1089 .. 3624 ;'/~1!89 . 1 of 2
, 9;0 N. K~I"h~o Avt!nuc. StillE! A300 • KlIilu;\, H<\wail 96734 T.'tphnll~; (80S' 2$4·5884
LABORATORY ANAL VB IS REPORT
TO: Wilson Okamoto & Associates
SAMPLts OF t Lagoon water REtE I ~t nATE: 6/26/89
SAMPLES!
tieasuremtnt (units) !
pH
AlkaHnity , (mgcaC03/L)
Calcium Hardness (mgCaC03/L)
Tota 1 Hardne~s (r.I;lCaC03/L)
Total Dissolved So! ids (1l19/L)
Sul fate (mg/l)
Ca 1 dum (m<;j/L)
Magnesium (mg/L)
So(,1ivtrl (mg/L)
I ron (mg/l)
Manganese (mg/\.)
Total Col i forlll (~IPN/100m 1 )
( h 1 0 t'i de ( mgl L)
'* REf-liAR KS :
O,.and HyUt Wai ea
7.50
91.2
1,180
7,900
36,300
2.900 t.
474
J. ,630
10.070
0.86
0.61
<2
20 ;000'
ATTN: Denis Shiu
, SAMPL~[): 6/26/S9 LOG NO.:' 3624
Ana'ysis . Dat@
lni ials
6/27 kt
6/27 k t
7/6 kt
7/6 kt
7/11 er
II 6 'e r
7/5 SAL
7/S SAL
7/5 SAL
7/5 aAL
7/5 GPll
7/5 8AL
7/21 el
f
o
Date/Analyst: 7/20/89 kt Pesticides & pees
Name: Laqool"l wat:.er-Grand Hyatt. Wai10Ct
I ._'
.lOB #: 1089-3624
DATE: 7/21/89 PAGE: 2 ot 2
compound (all units in mg/L unle$s othQrwise noted) -~--~--~-------------~-~-------------~-------~-----------~-------
Aldrin alpha-BRC beta-SHC delta-SHe Lindane Chlordane 4,4'-DDO 4,4'-ODE 4,4'-OOT Dieldrin Endosulfan I Endosultan II Endosulfan sulfate Endrin Endrin aldehyde Heptachlor Heptachlor epoy.ide Methoxychlor Toxaphene Aroehlor 1016 Arochlor 1221 Arochlor 1232 Aroc::hlor 1242 Arochlor 1~4a J\rochlor 1254 Arochlor 1260
<0.0001 <0.0001 <0.0001 <0.0001 <0.0001 <0.001 <0.0002 <0.0002 <0.0002 <0. 000'1 <0.0001 <0.0001 <0.0002 <0.0002 <0.0002 <0.0001 <0.0001 <0.0004 <0.003 <0.002 <0.006 <0.006 <0.004 <0.002 <0.001 <0.001
STEPHEN P. BOWLES President
Depth in feet
0.00 to 5.00 5.00 to 15.5
15.5 to 16.0 16 to 26.5 26.5 to 28 28 to 30 30 to 30.5 30.5 to 33.5 33.5 to 35 35 to 36 36 to 40 40 to 43.5 43.5 to 47 47 to 50 50 to 52 52 to 55 55 to 56.5 56.5 to 59.5 59.5 to 65 65 to 70 70 to 72.5 72.5 to 74 74 to 77 77 to 82 82 to 85 85 to 90 90 to 91.5 91.5 to 100 100 to 120
o ISLAND RESOURCES, LTD. Resource Management with Imagination
Water. Land. Energy
Grand Hyatt at Wailea Salt water test well
DRILLERS LOG
Description of Material
o
Dark brown sand and clinkers Light brown sand Basalt Basalt Cinder and red clay Medium hard basalt Basalt Basalt, very dense Weathered Basalt and black cinder Soft black cinder Medium hard basalt Dense Basalt Softer basalt Very dense basalt Very hard basalt Porous basalt Medium hard to hard basalt Very hard basalt porous basalt Very soft Soft dark brown Hard basalt Very hard basalt Slightly softer basalt Very hard basalt Very hard basalt Very hard basalt Medium hard basalt Basalt
P.O. Box 1656. Kamuela, Hawaii 96743
Telephone (808) 885-4759
JOHN WAIHEE GOVERNOR OF HAWAII
o o
STATE OF HAWAII DEPARTMENT OF LAND AND NATURAL. RESOURCES
COMMISSION ON WATER RESOURCE MANAGEMENT
P. O. BOX 621
HONOLULU. HAWAII 96609
WELL CONSTRUCTION PERMIT for
Grand Wailea Test Well Well No. 4126-01M
Wailea, Maui
WILLIAM W. PATY CHAIRPERSON
JOHN C. LEWIN. M.D. MICHAEL J. CHUN. Ph.D.
ROBERT S. NAKATA RICHARD H. COX. P.E.
GUY K. FUJIMURA
MANABU TAGOMORI. P.E. DEPUTY
. TO: Grand Wailea Co. clo Wilson Okamoto' Assoc. 1150 S. King Street Honolulu, Hawaii 96814
In accordance with the Department of Land and Natural Resources Administrative Rules, Section 13-168, entitled "Water Use, Wells, and Stream Diversion Works", your application to construct and test Well No. 4126-01M within Tax Map Key: 2-1-08: 89 is approved subject to the following conditions:
1. The Division of Water and Land Development (DOWALD), Geology-Hydrology Section, shall be notified at 548-7619, before any work covered by this permit commences.
2. The well shall be used for monitoring and testing only.
3. The following shall be submitted to DOWALD, P.O. Box 373, Honolulu, Hawaii 96809, within 30 days after completion of the well:
a. Well Completion Report.
b. Final elevation (referenced to mean sea level) by a Hawaiilicensed surveyor.
c. As-built sectional drawing of the well.
d. Plot plan and map showing the exact location of the well.
e. Driller's logs, geologic logs, and salinity logs.
f. Periodic reports of monitoring and testing results.
o WELL CONSTRUCTION PERMIT Well No. 4126-01M
o Page 2
4. The applicant shall comply with all applicable laws, rules, and ordinances.
5. This permit may be revoked if work is not started within six months of date of issuance or if work is suspended or abandoned for six months.
6. Upon discontinuance of use, the applicant shall seal the well with cement grout by permit from the Commission.
MAY 24 1989
Date of Issuance
cc: Department of Health, Drinking Water Program Ground Water Protection Program
Maui Dept. of Water Supply
h rperson Resource Management
o
flt WILSON OKAMOTO & ASSOCIATES. INC. ENGINEERS, ARCHITECTS AND PLANNERS
P.O. BOX 3530. HONOLULU, HAWAII 96811
***TWENTY FIVE AND NO/100***
'AY rOTHE )ROER )F
State of Hawaii Dept. of Land & Natural RDsource
W£LL CONSTR. P£((M11 FIL.ING t=E.E.
(412'-OIM)
ALA MOANA BRANCH BANK OF HAWAII HONOLULU, HAWAII
o
DATE
59-102 1213
NO. 27001 CHECK NO.
27001
AMOUNT
4/18/89 $25.00 WILSON OKAMOTO & ASSOCIATES, INC.
· .
Top Related