Protos®
Protos® 3400 (X)
Protos® 3400 (X) ........................................................................................................................................... 30
SMART MEDIA ......................................................................................................................................... 32
The functions ......................................................................................................................................... 33
Modules ................................................................................................................................................. 34
ProgaLog® 3000...................................................................................................................................... 37
System overview...................................................................................................................................... 38
Menu structure ....................................................................................................................................... 39
Display .................................................................................................................................................... 40
Product line ...................................................................................................................................... 41/112
Device equipment ................................................................................................................................... 45
Assembly examples ............................................................................................................................... 113
Dimension drawings .............................................................................................................................. 114
Specifications
Protos® 3400 (X) S and Protos® 3400 (X) C ................................................................................................... 46
pH 3400 (X)-032 module .............................................................................................................................. 52
pH 3400 (X)-033 module .............................................................................................................................. 56
pH 3400 (X)-035 module .............................................................................................................................. 60
COND 3400 (X)-041 module ......................................................................................................................... 64
CONDI 3400 (X)-051 module ........................................................................................................................ 68
OXY 3400 (X)-062 module ............................................................................................................................ 72
OXY 3400 (X)-063 module ............................................................................................................................ 76
OXY 3400 (X)-065 module ............................................................................................................................ 80
OXY 3400 (X)-066 module ............................................................................................................................ 84
OXY 3400 (X)-067 module ............................................................................................................................ 88
PHU 3400 (X)-110 module ............................................................................................................................ 92
OUT 3400 (X)-071 module ............................................................................................................................ 96
PID module 3400-121 ................................................................................................................................... 98
PROFIBUS COMPA 3400 X-081 module ...................................................................................................... 102
COMFF 3400 X-085 module ....................................................................................................................... 106
FIU 3400 X-140 / FIU 3400-141 module ...................................................................................................... 110
‘Please refer to separate catalog for sensors and fittings.’
For download of Ex certificates, please refer to our website: www.knick.de
Protos® 3400 (X)
This device will help you make considerable savings.The perfectly designed Protos® 3400 (X) measuring system is based on a modular hardware and software concept for liquid analy-sis and offers flexible solutions precisely tailored to the measuring task. It is also possible to easily measure several process variables such as pH/Cond, pH/pH, Cond/Oxy etc. with the appropriate con-figuration. Similar to a PC, the de-vice which is fitted with a total of 3 slots can be simply retrofitted or modified at any time.
With all these advantages, the Protos® 3400 (X) offers a previ-ously unknown level of function-ality and reliability, and with an extraordinarily high level of user comfort. A razor-sharp display guarantees superb legibility in the most diverse of light con-ditions. Also the integrated SMARTMEDIA card allows for the trouble-free saving of confi g-urations, software updates, and measurement data.
The hygienic stainless steel enclo-sure is intended for applications in– biotechnology– the pharmaceutical industry– the food processing industry
The rugged, corrosion-resistant coated steel enclosure stands up well to harsh industrial environ-ments.
For applications in– the chemical industry– the paper industry– power station engineering– water / waste-water technology
The Protos® 3400 (X) can be easily integrated into PROFIBUS PA or FOUNDATION Fieldbus networks.
30
Protos®
The modular measuring system for pH, conductivity and oxygen in safe and hazardous areas
Warranty
3 years!Warranty
Defects occurring within 3 years from delivery date shall be remedied free of charge at our works (carriage
and insurance paid by sender).
The facts ,
Protos® 3400 (X) S, tightly sealed stainless steel enclosure with hygienic design Protos® 3400 (X) C, rugged, corrosion-resistant coated steel enclosure Plaintext user interface according to NAMUR – simple and intuitive Great flexibility provided by modular technology Modular hardware and software concept permits retrofitting at any time 5 process variables measured simultaneously SMARTMEDIA card for saving and transmission of parameter settings, software updates, and measuring data High-resolution, transflective graphic display, white back-lighting – optimum legibility in all light conditions Operator guidance iconled 6 languages as standard Can be used globally thanks to VariPower® power supply 20 … 265 V AC/DC
Measuring circuits, galvanically isolated 2 current outputs and 4 swit ching contacts in the basic model 2channel measurement recorder, time and event- controlled, with extended resolution for fast changes Parameter set switchover, can be switched remotely Hold function, can be remote controlled KI recorder detects abnormalities in processes Sensocheck® sensor monitoring ISM Intelligent Sensor Manage-ment ServiceScope® – noise level monitoring of the pH input Sensor network diagram – synchronoptic representation of the sensor data Sensor wear monitor
Sensor load matrix Adaptive calibration timer – automatic standardization
Lightning protection Explosion protection: II 2(1) GD EEx me ib [ia] IIC T4 T 70 °C Control of Unical® 9000 (X) fully automated calibration system Control of Uniclean® 900 (X) fully automated cleaning system PROFIBUS PA FOUNDATION Fieldbus 3year warranty
31
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
32
Protos®
SMART MEDIA ,
Everything on a cardThe SMART MEDIA card (meas-uring only 4.5 by 3.7 cm and only 1 mm thick) is an extremely com-pact, very widely used memory expansion medium available to the Protos® system. The SMART-MEDIA card can be connected via the very inexpensive, commercially available adapter to RS 232 C, USB etc. or directly via a PCMCIA adapter to any PC.
For software updates and software functions– Contains the complete Protos®
software– Software functions can be
installed at a later date and disconnected via transaction numbers (TAN)
– Software updates to keep Protos® upgraded with the latest software – also on site
For parameters and the recording of data– 5 parameter sets can be filed
and loaded into the device– A parameter set contains all pa-
rameter data, facilitating rapid exchange and speedy complete parameter setting. Simple return to factory settings .
– Almost unlimited expansion of the measurement recorder
– Parameter sets can be trans-ferred from one device to an-other. This removes the need for the tiresome repetition of inputting parameters.
– The device parameters can be completely saved on a SMART MEDIA card and then archived directly or on a PC
– Extended logbook– Electronic Records and Elec-
tronic Signatures in accordance with the FDA 21 CFR Regula-tion, Part 11
SMARTMEDIA is a registered trademark of the Toshiba Corp. Japan
Simple operation: Simply insert the SMARTMEDIA card into the small slot on the rear of the front door.
33
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
The functions ,
Progress in perfectionIn addition to excellent features such as the universally used VariPower® 20 to 265 V AC/DC power supply, the time and event controlled 2-channel measure-ment re corder and the Sensocheck® sensor monitoring with sensor network diagram, the Protos® 3400 system can be fur-ther expanded with pioneering functions such as:
1. Early alarm detection with the KI recorder The KI recorder follows the course of the process and re-leases a message in the event of abnormalities. The monitor-ing is always carried out for the primary measured variable, e.g. pH or conductivity and par-allel to that for the tempera-ture. The visualization is graphi-cal with process and limit value variation for both variables.
2. Checking of batch processes using the KI recorder The KI recorder records the course of a batch (self-teaching function).
All further batches are then monitored for deviations from the saved course.
Sensor network diagram for pH measurementGraphical representation of the current sensor parameters on the display in a network dia gram– with slope, zero point, refe rence
impedance, glass im pedance, response time, calibration timer, sensorwear.
ServiceScope® monitors whether the pH in put sig nal lies within the input control range. Moreover, the representa-tion of the noise level over the time allows the distinction to be made between individual disturb-ances, periodic and broadband disturbances which is helpful for troubleshooting. In this way, it is possible to check whether regu-larly recurring disturbances, e.g. large consumers , which are regu-larly switched on or off can be simply detected. An error message is generated if the noise level ex-ceeds the failure limit.
KI recorder
Sensor network diagram
ServiceScope®
Tolerance band
t
pH
Alarm message
Slope
Zero point
Reference impedance
Glass impendanceResponse time
Calibration timer
Sensorwear50
0
100
Interference level
Failure
t
34
Protos®
Modules ,
The modulesUniversally interchangeableVarious user-defined plug-in measuring modules for measure-ment and control functions can be combined depending on the measuring task. They also facili-tate subsequent trouble-free expansion or modification.
Communication modules for functional expansions. In addition to the OUT module for the expan-sion of the output options already available as standard, other mod-ules are available, including mod-ules for PROFIBUS and FOUNDA-TION Fieldbus.
Combined with the PHU or FIU measuring and control module , Unical® 9000 (X) / Uniclean® 900 (X) and a remote calibration probe such as Ceramat® WA 150 or SensoGate® WA 130, the Protos® 3400 (X) is a fully automatic remote- controlled calibration and cleaning system.
If necessary, it can also record several measurement parameters in any combination with one device; pH/pH, Cond/Cond etc. or e.g. simultaneous pH and conductivity measurement.
Combined evaluation – i.e. the calculation of several measuring parameters e.g. for differential measurement or quasi-redundant measuring systems. Up to 3 meas-uring modules can be combined.
Plug & Play – the modules are sim-ply clicked into place in the slots provided, in any order. The mod-ules are automatically recognized. Very straightforward retrofitting or modification; hot-swap tech-nology.
Control module for convenient PID control. Analog and di gital outputs as well as limit value-monitoring.
35
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Measuring modules ,
PH measuring modulesInput module for analog pH meas-urement with glass electrodes, IS-FET (via active adapter) and enamel sensors. Simultaneous measurement of pH values, ORP and temperature also with ISM (Intelligent Sensor Management) and InduCon® sen-sors. – Sensocheck® electrode monito r-
ing for glass and reference electrodes
– Sensor monitor– Sensor wear monitor– Sensor load matrix– Sensor network diagram– ServiceScope® noise level
monitoring of the pH level– Adaptive calibration timer– Timer for sensor control– Calimatic® automatic calibration– KI recorder
COND measuring moduleInput module for conductivity measurement with 2 or 4-elec-trode sensors. Simultaneous measurement of electrical conductivity, resistivity, concentration, salinity and tem-perature. – Large measuring range with
2-electrode sensors due to special measuring process
– Sensocheck® polarization detection and monitoring of cable capacity
– Sensor monitor
CONDI measuring moduleInput module for conductivity measurement with commercial electrodeless sensors. Simultaneous measurement of electrical conductivity, resistivity, concentration, salinity and tem-perature.– Sensocheck® sensor monitoring– Sensor monitor– Can be used universally for
many commercial electrode less conductivity sensors. Adaptation via sensor ID.
OXY measuring modulesInput modules for measuring oxygen in liquids. Simultaneous measurement of the oxygen partial pressure, baromet-ric pressure and the temperature also with ISM (Intelligent Sensor Management) sensors. Calcula-tion of the oxygen saturation and concentration . For standard appli-cations and trace measurements
– Sensocheck® sensor monitoring
– monitoring of the membrane and electrolyte
– Sensor monitor– Sensor wear monitor– Sensor load matrix– Automatic correction of the
influence of barometric pressure– Also suitable for oxygen trace
measurement in the ppb range
PHU measurement and control moduleActivation of the fully automatic Unical® 9000 (X) / Uniclean® 900 (X) measurement, cleaning and calibration system.
– Integrated pH measurement input
– Manual, interval and time-controlled calling of calibration and rinsing programs
– 8 programs can be called
36
Protos®
Communication modules ,
OUT communication moduleGeneral output module for the expansion of outputs available as standard.– Four freely definable elec tronic
relay outputs– Two additional passive analog
outputs for further process variables
PROFIBUS COMPA communication modulePROFIBUS PA communication unit – Rapid cyclical transfer of
measured values with status– Function block model
(PROFIBUS Profile 3.0)– Hazardous location interface
according to the FISCO model– Prepared for SIMATIC PDM
access
FOUNDATION Fieldbus communication moduleExpansion for bus-capable field device – Rapid cyclical transfer of
measured values with status– Function block model– Hazardous location interface
according to the FISCO model– Prepared for AMS access
PID controller moduleConvenient PID controller. – Continuous controller for the
actuation of control valves– Quasi-continuous pulse length/
pulse frequency controller for the actuation of straightway valves or buffer solution pumps
– Two free limit value contacts e.g. for three-point control for the control of secondary control processes
FIU digital moduleEnable connection of intelligent digital InduCon® sensors and Unical® 9000 (X) / Uniclean® 900 (X) controllers for sensor lock-gates and support wireless trans-fer of measurement data (ComFu). – for RS 485 interfaces with
auxiliary power– two InduCon® sensors can be
used simultaneously
37
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
ProgaLog , ® 3000
The new PC software for offline parameterization and documenta-tion for Protos® process analyzers.
ProgaLog® 3000 is a PC-based tool for exceptionally easy para m-eterization of a Protos® process analysis system. It allows for com-prehensive parameterization of basic as well as multi-channel Protos® analyzers and, far beyond these, even of complete Unical® / Uniclean® systems. That covers all steps in a full-scale program for a fully automatic pH measuring system, including cleaning, auto-matic calibration and control of retractable fittings. In spite of its extensive parameterization capability, ProgaLog® is well- structured and easy to handle.
Comfortable operationExplorer-style display of the device configuration to keep track of and set up hardware options in self-explanatory fashion.– graphical user interface lists pa-
rameters and parameterization values in a table view
– uses familiar terms from the language selected for the Protos® measuring system
– program interface in German or English language
– Protos® hardware configuration is entered manually or read out from a stored configuration.
Value ranges of parameters, their interdependencies and im-plications of divergent hard- and software versions are observed
– pictorial representation of indi-vidual modules, true to the de-tail, down to the clamp terminal connections
– intuitive operation – graphic visualization of the
complete cleaning and calibra-tion cycles of a Unical® system, with optional live tracking in a diagram
Simple parameterizationUpon completing the parameter-ization of a Protos® process ana-lysis system on a PC, the para m-eter set can be transferred to the Protos® device with a SMART-MEDIA card. This also allows for “cloning”, i.e. identic ally parame-terizing several Protos® systems, with minimal effort. Of course,
this process can be reversed as well in order to read out an exist-ing Protos® parameterization from a SMARTMEDIA card, and change or document it on a PC. On the PC system, the parameter set can be archived, printed or modified and later retransferred to the Protos® analyzer.
Full and consistent documentationComplete Protos® configuration sets can be converted into Excel or PDF format at the touch of a button, which generates full, con-sistent documentation and allows for easy archiving of data. The printing function also provides a comfortable and simple way to keep paper copies on file. Proga-Log® 3000 works under Windows 2000 and XP. It is easy to install and can be run without adminis-trator privileges.
ORP
PRO
FIBU
S-PA
Refe
renc
e
Gla
ss
RTD
RTD
2 EL / 4 EL
Electrodeless sensor
O2, %µg/l, ppbmg/l, ppm
µS, mS/cm% by wt
µS, mS/cm% by wt
Module slot
Module slot
ContactsK1, K2, K3
AlarmK4
I 2
I 1
I 3
I 4
IV 2
IV 1
mA
mA
mA
mA
mA
mA
Module slot
pH, ORPMΩ, kΩ
Temp
Temp
Temp
Temp
COMPA
connector
connector
connector
Electroniccontacts
Electroniccontacts
connector
OK 1 OK 2
connector
SMARTMEDIA
VariPower®
connector
connector
Probe
0(4) … 20 mA
0(4) … 20 mA
Unical® 9000 Uniclean® 900
OXY3400(X)0623400(X)0633400(X)065 ISM3400(X)066 ISM3400(X)067 ISMmodules
OUT 3400(X)071 module
Protos® 3400 (X)
PID 3400(X)121 module
CONDI3400(X)051modules
COND3400(X)041module
pH3400(X)0323400(X)0333400(X)035 ISMmodule
COMPA3400 X081module
O2 sensor
ISM
FOU
ND
ATI
ON
Fie
ldbu
s
COMFF connector
COMFF3400 X085module
ISM
alternatively
ISM sensor with RTD
alternatively
ISM sensor with RTD
38
Protos®
Protos® 3400 (X)
System overview ,
Temp
pH, ORPMΩ, kΩ
Unical®
Uniclean®
connectorRTD
pH
Temp
PHU3400(X)110module
ComFu C
InduCon® 1
InduCon® 2
Unical® Uniclean®
FIU3400 X1403400 141module
connector
39
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Menu structure ,
Parameter settingParameter setting is divided into three levels: Viewing level, Op er ator level and Adminis-trator level.
Operator levelHere you can set the parameters which are authorized in the Administrator level. Only the parame ters which may be changed in every day operation appear.
DiagnosticsIn the Diagnostics menu you receive information about existing messages, the sensor condition and about the instrument itself. You can also dis-play the logbook here.
Administrator levelAll device param-eters can be set here. It is also possible to define which parameters are accessible in the Opera tor level using the marker setting.
CalibrationIn the Calibration menu, you select the calibration mode and execute the calibration.
Maintenance In order to carry out maintenance on the sensor, you can freeze the out -put current call up the current sensor data or activate a manual current source function for test purposes and manually set the controller.
Viewing levelIn the Viewing level, you can view all param-eters but not change them.
The menu key can be used to access the individual sub-menus via the function keys.
40
Protos®
Display ,
Innovative display
Measured value display with two primary values (above) and two sec-ondary displays (below), i.e. 4 measured values can be simultaneously represented.
Clear icon menu. Selected icon flashes black/gray.
Example of a message box, e.g. with safety information.
Menu logic based on MS Windows with scroll bar.
Selection of a configuration via ‘pull down’ menu.
The facts ,
Transflective LC graphic display (240 x 160 pixels), high resolution and contrast-rich, with half-tone visualization. Optimal legibility even in the most difficult light conditions thanks to white backlighting. Plaintext user interface according to NAMUR – simple and intuitive. Menu texts available in: German, English, French, Italian, Spanish and Swedish. Menu logic based on Windows standard. 2 softkeys with context-dependent functionality.
41
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Product line , for safe areas
Basic devices Order No.
Protos® 3400 C Basic device / coated stainless steel enclosure VariPower® power supply 20 ... 265 V AC/DC
3400 C
Protos® 3400 S Basic device / polished stainless steel enclosure VariPower® power supply 20 ... 265 V AC/DC
3400 S
Modules
PH 3400-032 pH module PH 3400032
PH 3400-033 pH module (double high resistant) PH 3400033
PH 3400-035 pH module (ISM) PH 3400035
COND 3400-041 Conductivity module COND 3400041
CONDI 3400-051 Inductive conductivity module CONDI 3400051
OXY 3400-062 Oxygen module (standard applications) OXY 3400062
OXY 3400-063 Oxygen module (trace measurements) OXY 3400063
OXY 3400-065 Oxygen module (standard applications/ISM) OXY 3400065
OXY 3400-066 Oxygen module (trace measurements/ISM) OXY 3400066
OXY 3400-067 Oxygen module (trace measurements/increased resolution/ISM) OXY 3400067
FIU 3400-141 Communication module InduCon®, Unical®, Uniclean®, ComFu FIU 3400141
PHU 3400-110 Communication module Unical® 9000 / Uniclean® 900 PHU 3400110
OUT 3400-071 Output expansion module OUT 3400071
PID 3400-121 PID controller module PID 3400121
COMPA 3400-081 PROFIBUS PA module COMPA 3400081
COMFF 3400-085 FOUNDATION Fieldbus module COMPA 3400085
42
Protos®
Protos® 3400 (X)
continued – Product line for hazardous locations
Basic devices Order No.
Protos® 3400 X C / VPW Basic device / Coated stainless steel enclosure, VariPower® power supply 85 ... 253 V AC
3400 X C / VPW
Protos® 3400 X C / 24 V Basic device / Coated stainless steel enclosure, Power supply 24 V AC/DC
3400 X C / 24 V
Protos® 3400 X S / VPW Basic device / Polished stainless steel enclosure, VariPower® power supply 85 ... 253 V AC
3400 X S / VPW
Protos® 3400 X S / 24 V Basic device / Polished stainless steel enclosure, Power supply 24 V AC/DC
3400 X S / 24 V
Modules
PH 3400 X-032 pH module PH 3400 X032
PH 3400 X-033 pH module (double high resistance) PH 3400 X033
PH 3400 X-035 pH module (ISM) PH 3400 X035
COND 3400 X-041 Conductivity module COND 3400 X041
CONDI 3400 X-051 Inductive conductivity module CONDI 3400 X051
OXY 3400 X-062 Oxygen module (standard applications) OXY 3400 X062
OXY 3400 X-063 Oxygen module (trace measurements) OXY 3400 X063
OXY 3400 X-065 Oxygen module (standard applications/ISM)) OXY 3400 X065
OXY 3400 X-066 Oxygen module (trace measurements/ISM) OXY 3400 X066
OXY 3400 X-067 Oxygen module (trace measurements/increased resolution/ISM) OXY 3400 X067
FIU 3400 X-140 Communication module InduCon®, Unical®, Uniclean® FIU 3400 X140
PHU 3400 X-110 Communication module Unical® 9000 X / Uniclean® 900 X PHU 3400 X110
OUT 3400 X-071 Output expansion module OUT 3400 X071
PID 3400 X-121 PID controller module PID 3400 X121
COMPA 3400 X-081 PROFIBUS PA module COMPA 3400 X081
COMFF 3400 X-085 FOUNDATION Fieldbus module COMFF 3400 X085
43
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Product line
Additional functions Order No.
KI recorder TAN SW 3400001
User-defined buffer sets (pH) TAN SW 3400002
ServiceScope® TAN SW 3400004
Tolerance band recorder (pH) TAN SW 3400005
User-defined current characteristic
TAN SW 3400006
TC ultrapure water (Cond) TAN SW 3400008
Concentration determination TAN SW 3400009
Dissolved oxygen measurement in carbonated beverages (e.g. beer)
TAN SW 3400010
ISFET functionality for pH 3400 (X)-035 measuring module
TAN SW 3400012
2nd channel InduCon® TAN SW 3400014
5 loadable parameter sets SMARTMEDIA/TAN SW 3400102
Measurement recorder SMARTMEDIA/TAN SW 3400103
Extended logbook SMARTMEDIA/TAN SW 3400104
Software update SMARTMEDIA/TAN SW 3400106
Software downgrade SMARTMEDIA/TAN on request
Electronic Records and Electronic Signatures in accordance with the FDA 21 CFR Regulation, Part 11
SMARTMEDIA/TAN SW 3400107
44
Protos®
Protos® 3400 (X)
Measuringmodules
PH 3400032module
PH 3400033module
PH 3400035module
COND 3400041module
CONDI 3400051module
OXY 3400062module
OXY 3400063module
OXY 3400065module
OXY 3400066module
OXY 3400067module
FIU 3400141module
Communication modules
OUT 3400071module
PID 3400121module
COMPA 3400081module
COMFF 3400085module
PHU 3400110module
Communication modules
OUT 3400X071module
PID 3400X121module
COMPA 3400X081 module
COMFF 3400X085module
PHU 3400X110module
Measuringmodules
PH 3400X032module
PH 3400X033module
PH 3400X035module
COND 3400X041module
CONDI 3400X051module
OXY 3400X062module
OXY 3400X063module
OXY 3400X065module
OXY 3400X066module
OXY 3400X067module
FIU 3400X140module
Functions: Activation with TAN
KI recorder
Buffer sets: User-defined
ISFET functionality
ServiceScope®
Tolerance band recorder
User defined current characteristic
TC ultrapure water
Concentration determination
Dissolved oxygen measurement in carbonated beverages
(e.g. beer)
2nd channel InduCon®
Basic device Protos® 3400(X)
Module slot
Module slot
Module slot
3 module slots
for measuring mo dules as well as
output or communi-cation mo dules, any
combination of additional functions
(TAN activation)
Safe areaHazardous area
continued – Product line
Functions: Activation with TAN & SMARTMEDIA card
Measured valuerecorder
5 loadable parameter sets
Extended logbook
Software update
AuditTrailFDA 21 CFR Part 11
45
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Device equipment ,
Device status • User-defined buffer sets x Activation of SMARTMEDIA card slot
•
2 parameter sets • Adaptive calibration timer
• 5 loadable parameter sets x
ORP measurement (SHE reference)
• USP function (Cond) • Measurement recorder x
Sensor network diagram
• ServiceScope® x Extended logbook x
Calimatic® • Tolerance band recorder x Software update x
Sensocheck® • User-defined current characteristic
x Dissolved oxygen measurement in carbonated beverages (e.g. beer)
x
VariPower® power supply
• TC ultrapure water (pH) • ISFET functionality x
2 current outputs • TC ultrapure water (Cond) x Electronic Records and Electronic Signatures in accordance with the FDA 21 CFR Regulation, Part 11
x
4 switching contacts • Concentration determination
x The properties indicated with • are already installed in the device as standard.
The properties indicated with x can either be retrofitted per TAN (Trans Action number) or per SMARTMEDIA card in connection with a TAN (see product line).
KI recorder x
46
Protos®
Protos® 3400 (X)
Display LC graphic display, white backlighting
Resolution 240 x 160 pixels
Languages German, English, French, Italian, Spanish, Swedish
Keypad NAMUR keypad, individual keys, no double assignments [meas] [menu] [‘] [±] [?] [¿] [enter] [softkey 1] [softkey 2], NAMUR LEDs red and green
Logbook Recording of function activations, appearance and disappearance of warning and failure messages, with date and time
Storage capacity Approx. 50 entries without SMARTMEDIA card, can be read from display and exported via SMARTMEDIA card
Extended logbook >50 000 entries, dependent on memory location of the SMARTMEDIA card
Measurement recorder 2-channel measurement recorder with marking of events (failure, maintenance request, function check, limit values)
Recording medium SMARTMEDIA card
Recording capacity >50 000 entries, dependent on memory location of the SMARTMEDIA card
Recording Process variables and span selectable
Recording method Snapshot, min/max or mean value
Time base 10 s … 10 h/pixel
Zoom function 10 fold zoom in the event of high rate of change
Sensor monitor Direct display of measured values from sensor for validation
KI recorder Adaptive representation of a process sequence with monitoring and signaling of critical process parameters
Device self-test Testing RAM, FLASH, EEPROM, display and keypad, records for QM documentation in accordance with ISO 9000
Clock Real-time clock with date
Power reserve Approx. 1 year (lithium battery)
Data retention Parameters and factory settings >10 years (EEPROM)
in case of power failure Logbook, statistics, records >1 year (lithium battery) Measurement recorder SMARTMEDIA
Module slots 3
Power supply 24 (–15 %) … 230 (+15 %) V AC/DC approx. 10 VA / 10 W
Specifications , Protos® 3400 (X) S and Protos® 3400 (X) C
47
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Specifications Protos® 3400 (X) S and Protos® 3400 (X) C
Overvoltage category II
Protection class I
Pollution degree 2 (EN 61010-1)
Wire cross-section 2.5 mm‡
Protection against electrical shock
Safe isolation of all extra-low voltages against mains according to EN 61010
OK 1 input Galvanically isolated (OPTO coupler)
Function Switches the device to HOLD mode (function check)
Switching voltage 0 ... 2 V AC/DC inactive 10 … 30 V AC/DC active
OK 2 input Galvanically isolated (OPTO coupler)
Function START/STOP KI recorder, switchover to second parameter set
Switching voltage 0 … 2 V AC/DC inactive 10 … 30 V AC/DC active
Current output I1 0/4 … 20 mA, (22 mA) max. 10 V, galv. isolated (with output I2 galvanically connected)
Load monitoring Error message if load is exceeded
Overrange*} 22 mA in the case of messages
Measurement error!} <0.2 % of current value +0.02 mA
Current source 0.00 … 22.00 mA
Current output I2 0/4 … 20 mA, (22 mA) max. 10 V, galv. isolated (with output I1 galvanically connected)
Load monitoring Error message if load is exceeded
Overrange*} 22 mA in the case of messages
Measurement error!} <0.2 % of current value +0.02 mA
Current source 0.00 … 22.00 mA
Switching contacts*} 4 relay contacts K1 … K4, floating / K1, K2, K3 are connected on one side
Loadability AC <30 V / <3 A, 90 VA DC <30 V / <3 A, 90 W
Usage*} K1 – K3, user definable as NAMUR maintenance request/function check, limit values, parameter set 2 active, rinsing contact, USP contact, K4 permanently set as alarm contact (NAMUR failure)
48
Protos®
Protos® 3400 (X)
continued – Specifications Protos® 3400 (X) S and Protos® 3400 (X) C
EMC NAMUR NE 21 and EN 61326
Emitted interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation class 2
Nominal operating conditions
Ambient temperature –20 … +55 °C, relative humidity 10 … 95 % not condensing Power supply 24 (–15 %) … 230 (+15 %) V AC/DC, frequency at AC 45 … 65 Hz
Transport/Storage temperature
–20 … +70 °C
Enclosure Protos® S: Stainless steel, polished 1.4305 Protos® C: Stainless steel, coated
Assembly Wall mounting/pipe mounting/panel mounting, sealed against panel
Dimensions See dimension drawing
Protection IP 65 / NEMA 4 X
Cable glands 5 times M20 x 1.5
Weight Approx. 3.2 kg plus approx. 150 g per module
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions
49
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Specifications Protos® 3400 X S and Protos® 3400 X C
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
Nominal operating conditions
Ambient temperature –20 … +50 °C, relative humidity 10 … 95 % not condensing
Power supply (EEx em IIC)
VPW: 100 (–15 %) … 230 (+10 %) V AC <15 VA, 48 … 62 Hz or 24 V: 24 V AC/DC AC 24 V (–15 %, +10 %) <15 VA, 48 … 62 Hz DC 24 V (–15 %, +20 %) <8 W
Overvoltage category II
Protection class I
Pollution degree 2 (EN 61010-1)
Wire cross-section 2.5 mm‡
Ground wire connection 2.5 mm‡, M4 screw (EN 61010-1, 6.5.1.2)
Protection against electrical shock
Safe isolation of all extra-low-voltage circuits (SELV) against mains through double insulation according to EN 61010-1
OK 1 input (EEx ib IIC)
Galvanically isolated (OPTO coupler), galvanic isolation up to 60 V, safe isolation through double insulation according to EN 61010-1
Function Switches the device to HOLD mode (function check)
Switching voltage Inactive 0 … 2 V AC/DC Active 10 … 30 V AC/DC EEx ib IIC Vi = 30 V
OK 2 input (EEx ib IIC)
Galvanically isolated (OPTO coupler) Galvanic isolation up to 60 V Safe isolation through double insulation in accordance to EN 61010-1
Function START/STOP KI recorder, switchover to second parameter set
Switching voltage Inactive 0 … 2 V AC/DC Active 10 … 30 V AC/DC EEx ib IIC Vi = 30 V
Current output I1 (EEx ib IIC)
0/4 … 20 mA, (22 mA) max. 10 V, galvanically isolated (with output I2 galvanically connected) Galvanic isolation up to 60 V Safe isolation due to double insulation according to EN 61010-1 EEx ib IIC Vo = 17 V Io = 90 mA Po = 400 mW
50
Protos®
Protos® 3400 (X)
Load monitoring Error message if load is exceeded
Overrange*} 22 mA in the case of messages
Measurement error!} <0.2 % of current value +0.02 mA
Current source 0.00 … 22.00 mA
Current output I2 (EEx ib IIC)
0/4 … 20 mA, (22 mA) max. 10 V, galvanically isolated (with output I1 galvanically connected) Galvanic isolation up to 60 V Safe isolation due to double insulation according to EN 61010-1 EEx ib IIC Vo = 17 V Io = 90 mA Po = 400 mW
Load monitoring Error message if load is exceeded
Overrange*} 22 mA with messages
Measurement error!} <0.2 % of current value +0.02 mA
Current source 0.00 … 22.00 mA
Switching contacts*}
(EEx ib IIC)4 relay contacts K1 … K4, floating / K1, K2, K3 connected on one side Galvanic isolation to 60 V Safe isolation due to double insulation according to EN 61010-1 EEx ib IIC Vi = 30 V Ii = 500 mA Pi = 10 W
Usage*} K1 – K3, user definable as NAMUR maintenance request / function check, limit values, parameter set 2 active, rinsing contact, USP contact, K4 permanently set as alarm contact (NAMUR failure)
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions
continued – Specifications Protos® 3400 X S and Protos® 3400 X C
51
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Protos 3400 20 … 253 V AC
Protos 3400 X VPW 100 … 253 V AC
Protos 3400 X 24 24 V AC/DC
Terminal assignments ,
52
Protos®
Protos® 3400 (X)
pH/ORP input**}
(EEx ia IIC)Simultaneous measurement of pH and ORP Integrated pH isolation amplifier, coupling capacitance <100 pF
Measurement range (MR) pH value –2.00 … 16.00 ORP value –2000 … +2000 mV rH value 0.0 … 42.5
Permissible voltage ORP + pH [mV] 2000 mV
Permissible cable capacitance
<2 nF
Glass electrode input!} Input resistance >1 x 10!‡ ohms Input current$} <1 x 10–!‡ A Impedance range 0.5 … 1000 Mohms
Reference electrode input!} Input resistance >1 x 10!= ohms Input current$} <1 x 10–!= A Impedance range 0.5 … 200 kohms
Measurement error1,2,3)
(display)pH value <0.02 TC: 0.001 pH/K ORP value <1 mV TC: 0.05 mV/K
Temperature input (EEx ia IIC)
Pt100/Pt1000/NTC 8.55 kohms / NTC 30 kohms*}, 3-wire connection, adjustable
Measurement range –20 to +150 °C (Pt 100 / Pt 1000 / NTC 30 kohms) –10 to +130 °C (NTC 8.5 kohms, Mitsubishi)
Resolution 0.1 °C
Measurement error1,2,3) 0.2 % meas. val. +0.5 K (<1 K with NTC >100 °C)
ORP*} Automatic conversion to standard hydrogen electrode with input of the reference electrode type
Sensocheck® Automatic monitoring of glass and reference electrode, message can be switched off
ServiceScope®*}
(SW 3400–004)Noise level monitoring of the pH input signal, representation on display
Sensoface® Provides information on the sensor condition: zero/slope, response time, calibration interval, Sensocheck®, can be switched off
Adaptive calibration timer*} Automatic adjustment of the calibration interval (Sensoface® information) dependent on the process variables
Sensor network diagram Graphic representation of the current sensor parameters in a network diagram on the display / slope, zero point, reference impedance, glass impedance, response time, calibration timer, deviation from calibration range (CalCheck®)
Sensor monitor Direct display of measured values from sensor for validation pH input / ORP input / glass electrode impedance / reference electrode impedance / RTD / temperature
KI recorder (SW 3400–001)
Adaptive representation of process flow with monitoring and signaling of critical process parameters
Tolerance band recorder (SW 3400–005)
Records zero point and slope of the electrode and the selected tolerance bands, graphical representation on the display.
Specifications , pH 3400 (X)-032 module
53
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Sensor standardization*} Operating modes: 1-/2-/3-point calibration (best fit line) – Calimatic® automatic buffer recognition – Input of individual buffer values – Stability criteria can be set – Product calibration – Data entry of pre-measured electrodes
Drift check*}
(stability criteria) adjustable
Fine: 1.2 mV/min (break-off after 180 s) Standard: 2.4 mV/min (break-off after 120 s) Coarse: 3.75 mV/min (break-off after 90 s)
Calimatic® buffer sets*} Fixed buffer sets: Knick/Mettler-Toledo: 2.00 / 4.01 / 7.00 / 9.21 Merck/Riedel: 2.00 / 4.00 / 7.00 / 9.00 / 12.00 DIN 19267: 1.09 / 4.65 / 6.79 / 9.23 / 12.75 NIST Standard: 4.006 / 6.865 / 9.180 Technical buffers to NIST: 1.68 / 4.00 / 7.00 / 10.01 / 12.46 Hamilton buffer A: 2.00 / 4.01 / 7.00 / 9.00 / 11.00 Hamilton buffer B: 2.00 / 4.00 / 7.00 / 9.00 / 11.00 Kraft: 2.00 / 4.00 / 7.00 / 9.00 / 11.00
– Manually enterable buffer set with max. three buffer tables – Buffer set loadable from SMARTMEDIA card
(SW 3400-002)
Nom. zero point*} pH 0 … 14, admissible span ¥pH = ±1
Nom. Slope*} 25 to 61 mV/pH (25 °C), admissible span 80 to 103 %
Zero point offset –200 … +200 mV (for ISFET)
ORP Automatic conversion to standard hydrogen electrode SHE when type of reference electrode is entered
ORP sensor standardization (Drift check)
Zero adjustable from –200 to +200 mV
Viso*} –1000 … +1000 mV
Calibration record / Statistics Recording of: Zero point, slope, Viso, response time, calibration process with date and time of the last three calibrations and the First Calibration
Temperature compensation media-related
Reference temperature 25 °C – Linear temperature coefficient, user defiend from –19.00 to 19.99 %/K – Ultrapure water 0 to 150 °C – Table 0 to 95 °C, user defined in 5 K steps
Power output For the operation of an ISFET adapter +3 V / 0.5 mA (Vo = +2.9 … +3.1 V / Ri = 360 ohms) –3 V / 0.5 mA (Vo = –3.5 … –3.0 V / Ri = 360 ohms)
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
continued – Specifications pH 3400 (X)-032 module
54
Protos®
Protos® 3400 (X)
continued – Specifications pH 3400 (X)-032 module
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
1) According to IEC 746 Part 1, at normal operating conditions 2) ±1 count 3) Plus sensor error 4) At 20 °C, doubles every 10 K *) User-defined **) pH/ORP input, ISFET supply voltage, temperature input galvanically connected, galvanically isolated up to 60 V against the other inputs, outputs, relay
contacts (safe isolation due to double insulation in accordance with EN 61010-1). EEx ia IIC: galvanic isolation up to 60 V.
55
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
56
Protos®
Protos® 3400 (X)
pH/mV Input (EEx ia IIC)
pH measurement with Pfaudler differential probes Input for measuring electrode Input for reference electrode Input for auxiliary electrode
Measurement range pH value –2.00 … 16.00
Permissible cable capacitance
<2 nF
Meas. electrode input!} Input resistance >1 x 10!‡ ohms Input current$} <1 x 10–!‡ A Impedance range 0.5 … 1000 Mohms
Reference electrode input!} (high resistance)
Input resistance >1 x 10!! ohms Input current$} <1 x 10–!! A Impedance range 0.5 … 1000 Mohms
Measurement error1,2,3)
(Display) pH value <0.02 TC< 0.001 pH/K mV value <1 mV TC< 0.05 mV/K
Temperature input*}
(EEx ia IIC)Pt100/Pt1000/NTC 30 kohms, 3-wire connection, adjustable
Measurement range –20 … +150 °C (Pt 100/Pt 1000/NTC 30 kohms)
Resolution 0.1 °C
Measurement error1,2,3) 0.2 % meas.val. +0.5 K (<1 K with NTC >100 °C)
Temperature compensation media-dependent
Reference temperature 25 °C – Linear temperature coefficient, user-defined from –19.00 … +19.99 % / K – Ultrapure water 0 … 120 °C – Table 0 … 95 °C, user-defined in 5 K steps
Sensocheck® Automatic monitoring of measurement and reference electrode, message can be switched off
ServiceScope®*}
(SW 3400–004)Noise level monitoring of the pH input signal, representation on display
Sensoface® Provides information on the sensor condition: zero/slope, response time, calibration interval, Sensocheck®, can be switched off
Adaptive calibration timer*} Automatic adjustment of the calibration interval (Sensoface® information) dependent on the process variables
Sensor network diagram Graphic representation of the current sensor parameters in a network diagram on the display / slope, zero point, reference impedance, glass impedance, response time, calibration timer, deviation from calibration range (CalCheck®)
Sensor monitor Direct display of measured values from sensor for validation pH input / meas. elelectrode impedance / ref. electrode impedance / temperature
Tolerance band recorder (SW 3400–005)
Records zero point and slope of the electrode and the selected tolerance bands, graphical representation on the display.
Specifications , pH 3400 (X)-033 module
57
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Sensor standardization*} Operating modes: 1-/2-/3-point calibration (best fit line) – Calimatic® automatic buffer recognition – Input of individual buffer values – Stability criteria can be set – Product calibration – Data entry of pre-measured electrodes
Drift check*}
(stability criteria) adjustable
Fine: 1.2 mV/min (break-off after 180 s) Standard: 2.4 mV/min (break-off after 120 s) Coarse: 3.75 mV/min (break-off after 90 s)
Calimatic® buffer sets*} Fixed buffer sets: Knick/Mettler-Toledo: 2.00 / 4.01 / 7.00 / 9.21 Merck/Riedel: 2.00 / 4.00 / 7.00 / 9.00 / 12.00 DIN 19267: 1.09 / 4.65 / 6.79 / 9.23 / 12.75 NIST Standard: 4.006 / 6.865 / 9.180 Technical buffers to NIST: 1.68 / 4.00 / 7.00 / 10.01 / 12.46 Hamilton buffer A: 2.00 / 4.01 / 7.00 / 9.00 / 11.00 Hamilton buffer B: 2.00 / 4.00 / 7.00 / 9.00 / 11.00 Kraft: 2.00 / 4.00 / 7.00 / 9.00 / 11.00
– Manually enterable buffer set with max. three buffer tables – Buffer set loadable from SMARTMEDIA card (SW 3400-002)
Nom. zero point*} pH 0 … 14, admissible span ¥pH = ±1
Nom. Slope*} 25 to 61 mV/pH (25 °C), admissible span 80 to 103 %
pHiso*} 0 … 14
Calibration record / Statistics Recording of: Zero point, slope, Viso, response time, calibration process with date and time of the last three calibrations and the First Calibration
Temperature compensation media-related
Reference temperature 25 °C – Linear temperature coefficient, user defiend from –19.00 to 19.99 %/K – Ultrapure water 0 to 150 °C – Table 0 to 95 °C, user defined in 5 K steps
Power output +3V (Vo = +2.9 … 3.1 V / Ri = 360 ohms) –3V (Vo = –3.5 … –3.0 V / Ri = 360 ohms)
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
continued – Specifications pH 3400 (X)-033 module
58
Protos®
Protos® 3400 (X)
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
1) According to IEC 746 Part 1, at normal operating conditions 2) ±1 count 3) Plus sensor error 4) At 20 °C, doubles every 10 K *) User-defined
continued – Specifications pH 3400 (X)-033 module
59
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
60
Protos®
Protos® 3400 (X)
pH/ORP input**} (EEx ia IIC)
Simultaneous measurement of pH and ORP with glass electrodes or ISFET SE 545 and InPro 3300 respectively Integrated pH isolation amplifier, coupling capacitance <100 pF control of von ISM sensors Input glass electrode or ISFET Input reference electrode Input ORP electrode or solution ground Input ISFET Input ISM sensor
Measurement range pH value –2.00 … 16.00 ORP value –2000 … +2000 mV rH value 0.0 … 42.5
Permissible voltage ORP + pH [mV] 2000 mV
Permissible cable capacitance
<2 nF (cable length max 20 m)
Glass electrode input**} Input resistance >1 x 10!‡ ohms Input current <1 x 10–!‡ A****} Impedance range 0.5 … 1000 Mohms
Reference electrode input**} Input resistance >1 x 10!= ohms Input current <1 x 10–!= A****} Impedance range 0.5 … 200 kohms
Measurement error***} (display)
pH value <0.02 ORP value <1 mV
Temperature input*} (EEx ia IIC)
Connection 2 wire, adjustable Pt 100 –50 … +150 °C / –58 … 302 °F Pt 1000 –50 … +150 °C / –58 … 302 °F NTC 30 kohms –20 … +150 °C / –4 … 302 °F NTC 8.55 kohms (Mitsubishi) –10 … +130 °C / 14 … 266 °F Balco 3 kohms 0 … +100 °C / 32 … 212 °F
Adjustable area ±5 K
Resolution 0.1 °C / 1 °F
Measurement error***} 0.2 % from measuring value +0.5 K (<1 K at NTC >100 °C)
Temperature compensation medium based
Reference temperature 25 °C – linear temperature coefficient, adjustable –19.00 … +19.99 % / K – ultra pure water 0 … 150 °C – Table 0 … 95 °C, adjustable in steps of 5 K
ORP Sensor adaption ORP*}
Display of potential difference ORP / reference electrode or automatically conversion to normal hydrogen electrode (SHE) with presetting type of reference electrode Zero offset –200 … +200 mV
ISFET (SW3400-012) Sensor adaption ISFET
Automatically determination of working point (zero offset) –200 … +200 mV
Specifications , pH 3400 (X)-035 module
61
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Sensor adaption pH electrode
3 point calibration (line of best fit) Operating modes: – Calimatic® automatic buffer recognition – Input of individual buffer values – Calibration with sample – Data entry of pre-measured electrodes – Automatic calibration with ISM
Drift check*}
adjustableFine: 1.2 mV/min (break-off after 180 s) Standard: 2.4 mV/min (break-off after 120 s) Coarse: 3.75 mV/min (break-off after 90 s)
Calimatic® buffer sets*} Fixed buffer sets: Knick/Mettler-Toledo: 2.00 / 4.01 / 7.00 / 9.21 Merck/Riedel: 2.00 / 4.00 / 7.00 / 9.00 / 12.00 DIN 19267: 1.09 / 4.65 / 6.79 / 9.23 / 12.75 NIST Standard: 4.006 / 6.865 / 9.180 Technical buffers to NIST: 1.68 / 4.00 / 7.00 / 10.01 / 12.46 Hamilton buffer A: 2.00 / 4.01 / 7.00 / 9.00 / 11.00 Hamilton buffer B: 2.00 / 4.00 / 7.00 / 9.00 / 11.00 Kraft: 2.00 / 4.00 / 7.00 / 9.00 / 11.00
– Manually enterable buffer set with max. three buffer tables – Buffer set loadable from SMARTMEDIA card (SW 3400-002)
Nom. zero point*} pH 0 … 14, admissable span ¥pH = ±1
Nom. slope*} 25 … 61 mV/pH (25 °C), admissable span 80 … 103 %
UIS*} –1000 … +1000 mV
Calibration record / statistics Recording of: Zero point, slope, UIS, response time, calibration process with date and time of the last three calibrations and the first calibration
Sensocheck® Glass electrode: automatically monitoring of glass and reference electrode ISFET sensor: Monitoring of ISFET parameters and reference electrode
Sensoface® Provides information on the sensor condition: zero point / slope, response timet, cal timer, Sensocheck®, sensor wear (only ISM)
Sensor network diagram Graphic representation of the current sensor parameters in a network diagramm on the display: zero point, slope, reference and glass impedance, response time, cal timer, sensor wear (only ISM)
Sensor monitor Display of direct sensor measure values for validation pH voltage / ORP / impedance Glass and reference electrode / RTD / temperature
Wear monitor Display of wear parameter sensor load / time of sensor operation / autoclaving cycles / CIP and SIP cycles
ISM (SW3400-013)
Intelligent Sensor Management Display of sensor data: manufacturer, serial number, calibration protocol, load matrix, sensor wear,…
KI recorder (SW3400-001)
Adaptive image of a process course with monitoring and signaling critical process parameter
continued – Specifications pH 3400 (X)-035 module
62
Protos®
Adaptive calibration timer*} Automatic adjustment of the calibration intervall (Sensoface® information) dependent on the process variables
ServiceScope®*} Noise level monitoring of the pH input signal, representation on display
Tolerance band recorder (SW3400-005)
Records zero point and slope of the electrode and the selected tolerance bands, graphical representation on the display
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) user-defined **) According to IEC 746 Part 1, at normal operating conditions ***) ±1 count, plus sensor error ****) at 20 °C, doubles every 10 K
continued – Specifications pH 3400 (X)-035 module
Protos® 3400 (X)
63
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
64
Protos®
Protos® 3400 (X)
Cond input*}
(EEx ia IIC)Operation with 2- or 4-electrode sensors
Conductivity 0.000 µS/cm … +1999 mS/cm
Resistivity 0.5 ohm cm … 999 Mohms cm Resolution depending on cell constant
Concentration 0.0 … 100.0 % by wt
Salinity 0.0 … 45.0 g/kg (0 … 35 °C)
Measurement range 4-electrode sensors: 0.1 µS x c … 2000 mS x c$} 2-electrode sensors: 0.1 µS x c … 200 mS x c$}
Measurement error1,2,3) <0.5 % meas. val. + 0.2 µS x c4,7) TC <0.05 %/K
Temperature input*}
(EEx ia IIC)Pt 100 / Pt 1000 / Ni 100 / NTC 30 kohms*}
3-wire connection, adjustable
Measurement range Pt 100 / Pt 1000: –50 to +250 °C NTC 30 kohms: –10 to +150 °C Ni100: –50 to +180 °C
Resolution 0.1 °C
Measurement error1,2,3) 0.2 % meas. val. +0.5 K
Temperature compensation*} – Without – Linear characteristic 00.00 … 19.99 %/K (reference temp user-defined) – NLF nat. water according to EN 27888 (reference temp 25 °C) – Ultrapure water with NaCl traces 0 … 120 °C (reference temp 25 °C) – Ultrapure water with HCl traces 0 … 120 °C (reference temp 25 °C) – Ultrapure water with NH3 traces 0 … 120 °C (reference temp 25 °C) – Ultrapure water with NaOH traces 0 … 120 °C (reference temp 25 °C)
Concentration determination*}
(SW 3400-009)
For the substances: HNO3 0 … 28 % by weight –20 … +50 °C 35 … 96 % by weight –20 … +50 °C HCl 0 … 18 % by weight –20 … +50 °C 22 … 39 % by weight –20 … +50 °C H2SO4%} 0 … 30 % by weight –17.8 … +110 °C 32 … 84 % by weight –17.8 … +115.6 °C 92 … 99 % by weight –17.8 … +115.6 °C NaOH&} 0 … 14 % by weight 0 … +100 °C 18 … 50 % by weight 0 … +100 °C NaCl 0 … 26 % by weight 0 … +60 °C User-defined concentration chart (5 x 5 x 5 values)
Sensocheck® Polarization detection and monitoring of the cable capacitance
Sensoface® Provides information on the sensor condition
Sensor monitor*} Display of the direct sensor values for validation – resistance / conductance / temperature
Sensor standardization*} Operating modes: – Automatic with NaCl or KCl solution – Manual: entry of conductivity – Product calibration/adjustment to vessel (fitting) – Entry off cell constant with simultaneous display of conductivity and temperature
Adm. cell constant 0.0050 … 199.99 cm–!
Calibration record Recording of: cell constant, calibration method, with date and time
Specifications , COND 3400 (X)-041 module
65
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Output characteristics*} – linear – trilinear – function – as desired using table
USP function Water monitoring in the pharmaceutical industry (USP) with possibility to enter a limit value (%). Output via relay contact (K1 to K3, BASE) possible. The USP value is available as USP% process variable (selectable for display, current output, limit value, measurement recorder).
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
1) To IEC 746 Part 1, at nominal operating conditions 2) ±1 count 3) Plus sensor error 4) c = 0.0050 … 199.99 cm–! 5) The range limits apply to 27 °C 6) The range limits apply to 25 °C 7) With conductivity > 500 mS x c: < 1 % meas. val. *) User-defined **) Cond input, temperature input galvanically connected, galvanically isolated up to 60 V against the other inputs, outputs, relay contacts (safe isolation
due to double insulation according to EN 61010-1). EEx ia IIC: galvanic isolation up to 60 V.
continued – Specifications COND 3400 (X)-041 module
66
Protos®
Protos® 3400 (X)
Terminal assignment ,
67
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
68
Protos®
Protos® 3400 (X)
CondI input*} (EEx ia IIC)
For SE 655, SE 656, SE 660 electrodeless sensors (and others)
Ranges SE 655/SE 656: 0000 µS/cm to 2000 mS/cm, resolution 1 µS/cm SE 660: 0.02 to 2000 mS/cm, resolution 10 µS/cm
Concentration 0.0 … 100.0 % by wt
Salinity 0.0 … 45.0 g/kg (0 … 35 °C)
Measurement error1,2,3) <0.5 % meas. val. +2 µS/cm
Admissible cable length Max. 20 m
Temperature input*}
(EEx ia IIC)Pt 100 / Pt 1000 / NTC 30 / NTC 100 kohms*}, 3-wire connection, adjustable
Measurement range Pt 100 / Pt 1000: –50 … +250 °C NTC 30 kohms, NTC 100 kohms: –10 … +150 °C
Resolution 0.1 °C
Measurement error1,2,3,6) 0.2 % meas. val. +0.5 K
Temperature compensation*} – Without – Linear characteristic 00.00 … 19.99 %/K (reference temp user-defined) – NLF nat. water according to EN 27888 (reference temperature 25 °C)
Concentration determination*}
SW 3400-009
HNO3 0 … 28 % by weight –20 … +50 °C 35 … 96 % by weight –20 … +50 °C HCl 0 … 18 % by weight –20 … +50 °C 22 … 39 % by weight –20 … +50 °C H2SO4%} 0 … 30 % by weight –17.8 … +110 °C 32 … 84 % by weight –17.8 … +115.6 °C 92 … 99 % by weight –17.8 … +115.6 °C NaOH&} 0 … 14 % by weight 0 … +100 °C 18 … 50 % by weight 0 … +100 °C NaCl 0 … 26 % by weight 0 … +60 °C User-defined concentration chart (5 x 5 x 5 values)
Sensor monitoring*} SensoCheck®, monitoring of primary coil and its lines for short circuit and secondary coil for open circuit, monitoring of the SensoCheck® loop (GainCheck®) with suitable sensors
Sensoface® Provides information on the sensor condition
Sensor standardization*} Operating modes: – Automatic with NaCl or KCl solution – Manual: Input of cell constants with simultaneous display of conductivity value and temperature – Sample calibration / adjustment to vessel – Adjustment of zero point – Adjustment of transfer ratio
Permissible cell factor 0.000 … 19.99 cm–!
Adm. transfer ratio 0.00 … 199.9
Calibration record Recording of: cell factor, transfer ratio, zero point, calibration process with date and time
Specifications , CONDI 3400 (X)-051 module
69
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Output characteristics*} – linear – trilinear – function – as desired using table
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
1) To IEC 746 Part 1, at nominal operating conditions 2) ±1 count 3) Plus sensor error 4) c = 0.0050 … 199.99 cm–!
5) The range limits apply to 27 °C 6) The range limits apply to 25 °C *) User-defined **) Cond input, temperature input galvanically connected, galvanically isolated up to 60 V against the other inputs, outputs, relay contacts (safe isolation
due to double insulation according to EN 61010-1). EEx ia IIC: galvanic isolation up to 60 V.
continued – Specifications CONDI 3400 (X)-051 module
70
Protos®
Protos® 3400 (X)
Terminal assignment ,
71
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
72
Protos®
Protos® 3400 (X)
DO input*}
EEx ia IICFor SE 703, SE 706, InPro6800 (Mettler Toledo) series, OXYFERM (Hamilton) and other sensors
Measuring current (sensor) 0 … 1800 nA, resolution 30 pA
Saturation 0.0 … 199.9 / 200 … 600 % Air 0.0 … 29.9 / 30 … 120 % O2
Measurement error1,2,3) <0.5 % meas. val. +0.5 %
Concentration (–10 ... 85 °C)
0.00 … 90.00 mg/l 0.00 … 90.00 ppm
Measurement error1,2,3) <0.5 % meas. val. +0.5 %
Partial pressure 0 … 2000 mbar
Barometric pressure 700 … 1100 mbar, manual: 0 … 9999 mbar
Salt correction 0.0 … 45.0 g/kg
Measuring current (sensor) 0 … 1800 nA
Resolution 0.030 nA
Polarization voltage 0 … –1000 mV (default setting –675 mV)
Adm. guard current ≤20 µA
Ref. voltage ±500 mV (voltage across ref. connection and anode)
Mesurement in gases 0 ... 2000 mbars 0 ... 9999 ppm 0.00 ... 29.9 / 30.0 ... 120.0 %vol (display only)
Current start / end As desired within range
Calibration methods Automatic – Air Product calibration (select ppm or %vol) Data entry Zero correction
Sensor monitoring*} Sensocheck®, monitoring of membrane and electrolyte
Sensoface® Provides information on the sensor condition: Zero/slope, response time, cal timer, Sensocheck®
Sensor network diagram Graphic representation of the current sensor parameters in a network diagram on the display: Slope, zero point, response time, calibration timer, Sensocheck®
Sensor monitor Direct display of measured values from sensor for validation: Sensor current / barometric pressure / temperature
Sensor standardization Operating modes: – Automatic calibration in air – Automatic calibration in air-saturated water – Product calibration saturation – Product calibration concentration – Data input zero/slope – Zero correction
Calibration record / Statistics Recording of: Zero, slope, response time, calibration method, with date and time of the last three calibrations and the First Calibration
Specifications , OXY 3400 (X)-062 module
73
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Specifications OXY 3400 (X)-062 module
Output characteristics*} – linear – trilinear – function – as desired using table
Temperature input**}
EEx ia IIC
Temperature probe*} NTC 22 kohms / NTC 30 kohms, 2-wire connection, adjustable
Measurement range –20 … +150 °C (–4 ... +302 °F)
Resolution 0.1 °C
Measurement error1,2,3) 0.2% meas. val. +0.5 K
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions 2) ±1 count 3) Plus sensor error **) DO input galvanically connected with temperature input, galvanically isolated up to 60 V against the other inputs, outputs, relay contacts (safe
isolation due to double insulation according to EN 61010-1). EEx ia IIC: galvanic isolation up to 60 V.
74
Protos®
Protos® 3400 (X)
Terminal assignment ,
75
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
76
Protos®
Protos® 3400 (X)
DO input*}
EEx ia IICFor SE 707, InPro6900 (Mettler Toledo) series, OXYFERM, Oxygold (Hamilton) and other sensors
Measuring current (sensor) 0 … 600 nA, resolution 10 pA
Saturation 0.0 … 199.9 % AIR 0.0 … 129.9 % O2
Measurement error1,2,3) 0.5 % meas. val. +0.5 %
Concentration (–10 … 80 °C)
0000 … 9999 µg/l (Overrange up to 19.99 mg/l) 0000 … 9999 ppb (Overrange up to 19.99 ppm)
Measurement error1,2,3) 0.5 % meas. val. +0.005 mg/l or 0.005 ppm
Partial pressure 0 … 2000 mbar
Barometric pressure 700 … 1100 mbar, manual: 0 … 9999 mbar
Salt correction 0.0 … 45.0 g/kg
Measuring current (sensor) 0 … 600 nA
Resolution 0.010 nA
Polarization voltage 0 … –1000 mV (default setting –675 mV)
Adm. guard current ≤20 µA
Ref. voltage ±500 mV (voltage across ref. connection and anode)
Measurement in gases 0 ... 2000 mbars 0 ... 9999 ppm 0.00 ... 29.9 / 30.0 ... 120.0 %vol (display only) 0.00 ... 120.0 %vol (1 %vol = 10,000 ppm)
Current start / end As desired within range
Calibration methods Automatic – Air Product calibration (select ppm or %vol) Data entry Zero correction
Sensor monitoring*} Sensocheck®, monitoring of membrane and electrolyte
Sensoface® Provides information on the sensor condition: Zero/slope, response time, cal timer, Sensocheck®
Sensor network diagram Graphic representation of the current sensor parameters in a network diagram on the display: Slope, zero point, response time, calibration timer, Sensocheck®
Sensor monitor Direct display of measured values from sensor for validation: Sensor current / barometric pressure / temperature
Sensor standardization*} Operating modes: – Automatic calibration in air – Automatic calibration in air-saturated water – Product calibration saturation – Product calibration concentration – Data input zero/slope – Zero point calibration
Calibration record / Statistics Recording of: Zero, slope, response time, calibration method with date and time of the last three calibrations and the First Calibration
Specifications , OXY 3400 (X)-063 module
77
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Specifications OXY 3400 (X)-063 module
Output characteristics*} – linear – trilinear – function – as desired using table
Temperature input**}
(EEx ia IIC)
Temperature probe*} NTC 22 kohms / NTC 30 kohms, 2-wire connection, adjustable
Measurement range –20 … +150 °C
Resolution 0.1 °C
Measurement error1,2,3) 0.2% meas. val. + 0.5 K
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions 2) ±1 count 3) Plus sensor error **) DO input galvanically connected with temperature input, galvanically isolated up to 60 V against the other inputs, outputs, relay contacts (safe
isolation due to double insulation in accordance with EN 61010-1). EEx ia IIC: galvanic isolation up to 60 V.
78
Protos®
Protos® 3400 (X)
Terminal assignment ,
79
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
80
Protos®
Protos® 3400 (X)
DO input**} (EEx ia IIC)
For SE 706, Inpro 6800 (Mettler Toledo), OXYFERM (Hamilton) and other sensors Control and evaluation of ISM sensors
Measuring range Measuring current 0 … 1800 nA, resolution 30 pA
Measurement error <0.5 % meas. val. + 0.1 nA + 0.005 nA/K
Saturation (–10 … +80 °C)
0.0 … 199.9 / 200 … 600 % Air 0.0 … 29.9 / 30 … 120 % O2
Concentration (–10 … +80 °C)
0000 … 9999 µg/l (overrange up to 19.99 mg/l) 0000 … 9999 ppb (overrange up to 19.99 mg/l) 0.00 … 200.00 mg/l 0.00 … 200.00 ppm
Volume concentration in gas 0000 … 9999 ppm / 0.0 … 120 %
Partial pressure 0 … 5000 mbar
Pressure correction Barometric pressure 700 … 1100 mbar manual correction 0 … 9999 mbar external by current input 0 … 9999 mbar
Salt correction 0,0 … 45.0 g/kg
Polarization voltage 0 … –1000 mV, default setting –675 mV (resolution 5 mV)
Admissible guard current ≤20 µA
ISM Intelligent Sensor Management Display of sensor data: manufacturer, serial number, calibration protocol, load matrix, sensor wear …
Sensoface® Sensor network diagram
Provides information on the sensor condition: zero / slope, response time, cal timer, Sensocheck®, sensor wear
Sensor monitoring*} Sensocheck® (not for sensors with guard) monitoring of membrane and electrolyte
Sensor monitor Direct display of measured values from sensor for validation: sensor current / barometric pressure / temperature
Sensor standardization*} Operation modes: – Automatic calibration in air – Automatic calibration in air-saturated water – Product calibration saturation – Product calibration concentration – Data input zero / slope – Zero point calibration – Automatic calibration by ISM
Calibration record / Statistics Recording of: Zero, slope, response time, calibration method with date and time of the last three calibrations and the First Calibration
Output characteristics*} – linear – trilinear – function – as desired using table
Specifications , OXY 3400 (X)-065 module
81
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Temperature input**} (EEx ia IIC)
Temperature probe: NTC 22 kohms, NTC 30 kohms 2-wire connection, adjustable
Measure range –20 … +150 °C / –4 … +302 °F
Resolution 0.1 °C
Measurement error1, 2, 3) 0.2 % meas. val. + 0.5 K (<1 K at T >100 °C)
Current input (EEx ia IIC)
for differential pressure transmitters
Pressure range 0 … 9999 mbar
Current range 0(4) … 20 mA / 50 ohms Beginning / end user-defined within the pressure range
Resolution <1 %
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) user-defined 1) according DIN IEC 746 Part 1, at nomimal operatiing conditions 2) ±1 Digit 3) additional sensor error **) DO input interconnected galvanically with temperature input, all other inputs, outputs, switching contacts are galvanically insulated up to 60 V
(safe isolation by double insulation according EN 61010-1).
continued – Specifications OXY 3400 (X)-065 module
82
Protos®
Protos® 3400 (X)
Terminal assignment ,
83
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
84
Protos®
Protos® 3400 (X)
DO input**} (EEx ia IIC)
For SE 707, Inpro 6900 (Mettler Toledo), OXYGOLD (Hamilton) and other sensors Control and evaluation of ISM sensors
Measuring range Measuring current 0 … 600 nA, resolution 10 pA
Measurement error <0.5 % meas. val. + 0.05 nA + 0.005 nA/K
Saturation (–10 … +80 °C)
0.0 … 199.9 / 200 … 600 % Air 0.0 … 29.9 / 30 … 120 % O2
Concentration (–10 … +80 °C)
0000 … 9999 µg/l (overrange up to 19.99 mg/l) 0000 … 9999 ppb (overrange up to 19.99 mg/l) 0.00 … 200.00 mg/l 0.00 … 200.00 ppm
Volume concentration in gas 0000 … 9999 ppm / 0.0 … 120 %
Partial pressure 0 … 5000 mbar
Pressure correction Barometric pressure 700 … 1100 mbar manual correction 0 … 9999 mbar external by current input 0 … 9999 mbar
Salt correction 0.0 … 45.0 g/kg
Polarization voltage 0 … –1000 mV, default setting –675 mV (resolution 5 mV)
Admissible guard current ≤20 µA
ISM Intelligent Sensor Management Display of sensor data: manufacturer, serial number, calibration protocol, load matrix, sensor wear …
Sensoface® Sensor network diagram
Provides information on the sensor condition: zero / slope, response time, cal timer, Sensocheck®, sensor wear
Sensor monitoring*} Sensocheck® (not for sensors with guard) monitoring of membrane and electrolyte
Sensor monitor Direct display of measured values from sensor for validation: sensor current / barometric pressure / temperature
Sensor standardization*} Operation modes: – Automatic calibration in air – Automatic calibration in air-saturated water – Product calibration saturation – Product calibration concentration – Data input zero / slope – Zero point calibration – Automatic calibration by ISM
Calibration record / Statistics Recording of: Zero, slope, response time, calibration method with date and time of the last three calibrations and the First Calibration
Output characteristics*} – linear – trilinear – function – as desired using table
Temperature input**} (EEx ia IIC)
Temperature probe: NTC 22 kohms, NTC 30 kohms 2-wire connection, adjustable
Specifications , OXY 3400 (X)-066 module
85
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Measure range –20 … +150 °C / –4 … +302 °F
Resolution 0.1 °C
Measurement error1, 2, 3) 0.2 % meas. val. + 0.5 K (<1 K at T >100 °C)
Current input (EEx ia IIC) for differential pressure transmitters
Pressure range 0 … 9999 mbar
Current range 0(4) … 20 mA / 50 ohms Beginning / end user-defined within the pressure range
Resolution <1 %
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) user-defined 1) according DIN IEC 746 Part 1, at nomimal operatiing conditions 2) ±1 Digit 3) additional sensor error **) DO input interconnected galvanically with temperature input, all other inputs, outputs, switching contacts are galvanically insulated up to 60 V
(safe isolation by double insulation according EN 61010-1).
continued – Specifications OXY 3400 (X)-066 module
86
Protos®
Protos® 3400 (X)
Terminal assignment ,
87
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
88
Protos®
Protos® 3400 (X)
DO input*} (EEx ia IIC)
For SE 707, Inpro 6900(i)/6950(i) (Mettler Toledo), OXYGold (Hamilton) and other sensors Control and evaluation of ISM sensors
Input range 1$}
Measurement errorMeasuring current 0 … 600 nA, resolution 10 pA <0.5 % meas. val. +0.05 nA +0.005 nA/K
Input range 2$} Measurement error
Measuring current 0 … 10000 nA, resolution 166 pA <0.5 % meas. val. +0.8 nA +0.08 nA/K
Measuring range with “sensor type 01 (traces)” or “others”
Saturation (–10 … +80 °C)
0.000 … 150.0 % Air 0.000 … 30.00 % O2
Concentration DO (–10 … +80 °C)
0000 … 9999 µg/l / 10.00 … 19.99 mg/l 0000 … 9999 ppb / 10.00 … 19.99 mg/l
Volume concentration in gas 0000 … 9999 ppm / 1.000 … 50.00 %
Partial pressure 00.00 … 500.0 mbar
Measuring range with “sensor type 001 (traces)”
Saturation (–10 … +80 °C)
0.000 … 150.0 % Air 0.000 … 30.00 % O2
Concentration DO (–10 … +80 °C)
000.0 … 9999 µg/l / 10.00 … 19.99 mg/l 000.0 … 9999 ppb / 10.00 … 19.99 ppm
Volume concentration in gas 000.0 … 9999 ppm / 1.000 … 50.00 %
Partial pressure 0.000 … 500.0 mbar
Pressure correction Barometric pressure 700 … 1100 mbar manual correction 0 … 9999 mbar external by current input 0 … 9999 mbar external by Profibus PA or Foundation Fieldbus 0 … 9999 mbar
Salt correction 0.0 … 45.0 g/kg
Polarization voltage 0 … –1000 mV, default setting –675 mV (resolution 5 mV)
Admissible guard current ≤20 µA
ISM Intelligent Sensor Management Display of sensor data: manufacturer / serial number / calibration protocol / load matrix / sensor wear …
Sensoface® Sensor network diagram
Provides information on the sensor condition: zero / slope / response time / cal timer / Sensocheck® / sensor wear
Sensor monitoring*} Sensocheck® monitoring of membrane and electrolyte
Sensor monitor Direct display of measured values from sensor for validation: sensor current / barometric pressure / temperature
Specifications , OXY 3400 (X)-067 module
89
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Wear monitor Display of wear parameter: sensor wear / sensor running time / cycle of autoclaving / cycle of SIP and CIP
Sensor standardization*} Operation modes: – Automatic calibration in air – Automatic calibration in air-saturated water – Product calibration saturation – Product calibration concentration – Data input zero / slope – Zero point calibration – Automatic calibration by ISM
Calibration record / Statistics Recording of: Zero, slope, response time, calibration method with date and time of the last three calibrations and the First Calibration
Output characteristics*} – linear – trilinear – function – as desired using table
Temperature input**}
(EEx ia IIC)Temperature probe: NTC 22 kohms, NTC 30 kohms 2-wire connection, adjustable
Measure range –20 … +150 °C / –4 … +302 °F
Resolution 0.1 °C
Measurement error1, 2,3) 0.2 % meas. val. + 0.5 K (<1 K at T >100 °C)
Current input (EEx ia IIC)
for differential pressure transmitters
Pressure range 0 … 9999 mbar
Current range 0(4) … 20 mA / 50 ohms Beginning / end user-defined within the pressure range
Resolution <1 %
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
continued – Specifications OXY 3400 (X)-067 module
90
Protos®
Protos® 3400 (X)
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) user-defined 1) according DIN IEC 746 Part 1, at nomimal operatiing conditions 2) ±1 Digit 3) additional sensor error 4) automatically change of measuring range **) DO input interconnected galvanically with temperature input, all other inputs, outputs, switching contacts are galvanically insulated up to 60 V
(safe isolation by double insulation according EN 61010-1).
continued – Specifications OXY 3400 (X)-067 module
91
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
92
Protos®
Protos® 3400 (X)
pH input*} EEx ia IIC
Communication with Unical® 9000 (X) / Uniclean® 900 (X) and simultaneous measurement of pH and ORP with glass electrodes Integrated pH isolation amplifier, coupling capacitance <100 pF
Input Glass electrode Input Reference electrode Input (SG) solution GND or redox electrode (ORP)
Measurement range pH value –2.00 … 16.00 ORP value –2000 … +2000 mV rH value 0.0 … 42.5
Permissible voltage ORP + pH [mV] 2000 mV
Permissible cable capacitance
<2 nF
Glass electrode input!} Input resistance >1 x 10!‡ ohms Input current <1 x 10–!‡ A$}
Impedance range 0.5 … 1000 Mohms
Reference electrode input!} Input resistance >1 x 10!= ohms Input current <1 x 10–!= A$}
Impedance range 0.5 … 200 kohms
Measurement error1,2,3)
(display)pH value <0.02 TC <0.001 pH/K ORP value <1 mV TC <0.05 mV/K
Temperature input*} **}
EEx ia IICPt 100 / Pt 1000 / NTC 30 kohms / NTC 8.55 kohms (Mitsubishi)*}
2-wire connection, adjustable
Measurement range –20 … +150 °C –10 … +130 °C (NTC 8.55 kohms)
Resolution 0.1 °C
Measurement error1,2,3) 0.2 % meas. val. +0.5 K (<1 K with NTC >100 °C)
Temperature compensation media-related
Reference temperature 25 °C – Linear temperature coefficient, user-defined –19.99 … 19.99 %/K – Ultrapure water 0 … 150 °C – Chart 0 … 95 °C, user-defined in 5 K steps
ORP*} Automatic conversion to standard hydrogen electrode with input of the reference electrode type
ORP sensor standardization Zero adjustable from –200 … +200 mV
pH sensor standardization*} 3-point calibration (best fit line); Operating modes: – Calimatic automatic buffer recognition – Input of individual buffer values – Sample calibration – Data entry of pre-measured electrodes
Specifications , PHU 3400 (X)-110 module
93
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
pH sensor standardization*} with Unical®
Program start at Unical® 9000 (X)
Drift check*}
(stability criteria) adjustable
Fine: 1.2 mV/min (break-off after 180 s) Standard: 2.4 mV/min (break-off after 120 s) Coarse: 3.75 mV/min (break-off after 90 s)
Calimatic® buffer sets*} Fixed buffer sets: Knick/Mettler-Toledo: 2.00 / 4.01 / 7.00 / 9.21 Merck/Riedel: 2.00 / 4.00 / 7.00 / 9.00 / 12.00 DIN 19267: 1.09 / 4.65 / 6.79 / 9.23 / 12.75 NIST Standard: 4.006 / 6.865 / 9.180 Technical buffers to NIST: 1.68 / 4.00 / 7.00 / 10.01 / 12.46 Hamilton buffer A: 2.00 / 4.01 / 7.00 / 9.00 / 11.00 Hamilton buffer B: 2.00 / 4.00 / 7.00 / 9.00 / 11.00 Kraft: 2.00 / 4.00 / 7.00 / 9.00 / 11.00
– Manually enterable buffer set with max. three buffer tables – Buffer set loadable from SMARTMEDIA card (SW 3400-002)
Nom. zero point*} pH 0 … 14, calibration range ¥pH = ±1
Nom. slope (25 °C)*} 25 … 61 mV/pH; calibration range 80 … 103 %
Viso*} –1000 … +1000 mV
Calibration record Recording of: Zero point, slope, Viso, response time, calibration process with date and time
Statistics Recording of: Zero point, slope, Viso, response time, glass and reference impedance with date and time of the last three calibrations and the First Calibration
Sensocheck® Automatic monitoring of glass and reference electrode, messages can be disabled
Sensoface® Provides information on the sensor condition: Zero point/slope, response time, calibration interval, Sensocheck® can be disabled
Sensor network diagram Graphical representation of current sensor parameters in a network diagram on the display
Sensor monitor Direct display of measured values from sensor for validation pH voltage / ORP voltage / glass el. impedance / ref. el. impedance / temperature
KI recorder (SW3400-001)
Adaptive representation of a process sequence with monitoring and signaling of critical process parameters
Adaptive calibration timer*} (SW3400-003)
Automatic standardization of the calibration interval (Sensoface® information) depending on the process variables
Tolerance band recorder (SW3400-005)
Tolerant calibration, tolerance limits adjustable, graphical recording of zero point and slope of the last 40 calibrations
ServiceScope®*}
(SW 3400-004)Monitoring of the inputs for overdrive, representation on display
Sensor monitoring*}
adjustable (SW 3400-010)Criteria for sensor network diagram, Sensoface® and NAMUR messages individually adjustable
continued – Specifications PHU 3400 (X)-110 module
94
Protos®
Protos® 3400 (X)
continued – Specifications PHU 3400 (X)-110 module
RS 485**} EEx ia IIC
Bidirectional serial interface to Unical® 9000 (X) / Uniclean® 900 (X)
Transfer rate 1200 Bd for Unical® 9000 (X) (9600 Bd) 8 data bits / 1 stop bit / No parity
Monitoring CRC16
Power supply output**}
EEx ia IICFor the operation of Unical® 9000 (X) / Uniclean® 900 (X)
Operating data 6.8 V (±10 %) / 15 mA
Unical® / Uniclean®
controllerManual, interval and time-controlled calling of calibration and rinsing programs
Programs 8 programs can be called – 5 programs with fixed sequences, times can be changed – 3 freely configurable programs
Diagnostics Unical® network diagram, graphical representation of the Unical® status
Maintenance Control of the individual valves and pumps with mode indicators
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions 2) ±1 count 3) Plus sensor error 4) at 20 °C, doubles every 10 K **) pH input galvanically connected with temperature input, galvanically isolated up to 60 V against the other inputs, outputs, relay contacts (safe
isolation due to double insulation in accordance with EN 61010-1). EEx ia IIC: galvanic isolation up to 60 V.
95
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
96
Protos®
Protos® 3400 (X)
Current output I3,**}
passive EEx ib IIC
0/4 … 20 mA, (22 mA) max. 10 V, floating (galvanically connected to output I4)
Supply voltage 3 … 30 V (e.g. isolated transmitter supply)
Load monitoring Error message if load is exceeded
Overrange*} 22 mA with messages
Measuring error!} <0.25 % of current value +0.05 mA
Start/end of scale*} As desired within range
Current source 0.00 … 22.00 mA
Current output I4,**}
passive EEx ib IIC
0/4 … 20 mA, (22 mA) max. 10 V, floating (galvanically connected to output I3)
Supply voltage 3 … 30 V (e.g. isolated transmitter supply)
Load monitoring Error message if load is exceeded
Overrange*} 22 mA with messages
Measuring error!} <0.25 % of current value +0.05 mA
Start/end of scale*} As desired within range
Current source 0.00 … 22.00 mA
Switching outputs K5–K8**} EEx ib IIC
4 electronic relay outputs, passive, polarized, floating, inter-connected
Voltage drop <1.2 V
Loadability DC: Vmax = 30 V, Imax = 100 mA
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Specifications , OUT 3400 (X)-071 module
97
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Specifications OUT 3400 (X)-071 module
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions **) Current outputs I3, I4 and switching outputs K5–K8 galvanically isolated up to 60 V against each other and against the other inputs, outputs, relay
contacts (safe isolation due to double insulation in accordance with EN 61010-1). EEx ib IIC: galvanic isolation up to 60 V.
Terminal assignment ,
98
Protos®
Protos® 3400 (X)
Analog controller output**} IV 1 / IV 2 EEx ib IIC
0/4 … 20 mA, passive (IV 1 / IV 2 galvanically connected)
Supply voltage 3 … 30 V (e.g. isolated transmitter supply)
Load monitoring Error message if load is exceeded
Overrange*} 22 mA with messages
Measuring error!} <0.25 % of current value +0.05 mA
Application Actuation of analog control valves or mixing valve
Digital controller output**} KV 1 / KV 2 EEx ib IIC
Electronic relay outputs, polarized, floating (galvanically connected with output K9/K10)
Voltage drop <1.2 V
Loadability DC: Vmax = 30 V, Imax = 100 mA
Application Actuation of straightway valves or pumps
PID process controller Continuous controller via the current outputs IV1, IV2 or quasi-continuous controller via the KV1, KV2 relay outputs
Controlled variable*} Freely selectable, depending on the measuring modules installed
Setpoint specification*} As desired within range
Neutral zone*} As desired within range
P-action*} Controller gain Kp: 0010 … 9999 %
I-action*} Reset time Tr: 0000 … 9999 s (0000 s = no integral action)
D-action*} Rate time Td: 0000 … 9999 s (0000 s = no derivative action)
Pulse length controller*} 0001 … 0600 s, min. ON time 0.5 s
Pulse frequency controller*} 0001 … 0180 min–!
Response with FCT check*} (HOLD)
Controller output Y = const. or controller output Y = 0
Man. controller output Manual input of Y to test or start up processes, Bumpless changeover to automatic if I-action ≠ 0000
Digital controller output**} K9 / K10 EEx ib IIC
Electronic relay outputs, polarized, floating
Voltage drop <1.2 V
Loadability DC: Vmax = 30 V, Imax = 100 mA
Application Limit monitoring or pre-control (3-point controller), process variable, threshold, hysteresis, contact type (N/C, N/O), switch on / switch off delay definable as desired
Specifications , PID module 3400-121
99
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
continued – Specifications PID module 3400-121
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) User-defined 1) To IEC 746 Part 1, at nominal operating conditions **) IV1, IV2 and KV1 / KV2 / KV9 / KV10 galvanically isolated up to 60 V against each other and against the other inputs, outputs, relay contacts
(safe isolation due to double insulation according to EN 61010-1).
100
Protos®
Protos® 3400 (X)
Terminal assignment ,
101
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
102
Protos®
Protos® 3400 (X)
PROFIBUS PA*} EEx ia II
Digital communication in hazardous locations via current modulation
Physical interface MBP-IS!} (according to EN 61158-2), for use in a FISCO system
Transfer rate 31.25 kBit/S
Communication protocol PROFIBUS DP-V1
Profile PROFIBUS PA 3.0
Address range 1 … 126, factory setting 126, can be set on device
Supply voltage FISCO ≤17.5 V (trapezoidal or rectangular characteristic) ≤24 V (linear characteristic)
Current consumption <12 mA
Max. current in case of fault (FDE)
<15 mA
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) Galvanic isolation up to 60 V 1) MBP-IS = Manchester Bus Powered – Intrinsic Safety
Specifications , PROFIBUS COMPA 3400 X-081 module
103
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
104
Protos®
Protos® 3400 (X)
Communication model ,
AI 1Analog Input Function Block
Physical Block Global Status
AI 2Analog Input Function Block
AI 3Analog Input Function Block
AI 4Analog Input Function Block
Module Selection
Pro
cess
Vari
ab
le S
ele
ctio
n
Protocols
Calibration
AO Analog Output
DI 1 Digital Input
DI 2 Digital Input
DI 3 Digital Input
DI 4 Digital Input
DO 1 Digital Out.
DO 2 Digital Out.
DO 3 Digital Out.
DO 4 Digital Out.
Meas. Value Correction
Unical® Status
CONTACT Status
Unical® Message
Unical® Step
HOLD Control
PARSET
Unical® Control
LOCK Control
Module I
Module II
Calc. Block I
Calc. Block II
ATB 1Analyzer Transducer Block
ATB 2Analyzer Transducer Block
ATB 3Analyzer Transducer Block
ATB 4Analyzer Transducer Block
AI 5Analog Input Function Block
AI 6Analog Input Function Block
AI 7Analog Input Function Block
AI 8Analog Input Function Block
Module Selection
Pro
cess
Vari
ab
le S
ele
ctio
n
Protocols
CalibrationModule I
Module II
Calc. Block I
Calc. Block II
ATB 5Analyzer Transducer Block
ATB 6Analyzer Transducer Block
ATB 7Analyzer Transducer Block
ATB 8Analyzer Transducer Block
105
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
106
Protos®
Protos® 3400 (X)
FF-H1 Digital communication by current modulation within hazardous locations
Physical interface according to DIN EN 61158-2 (IEC 61158-2)
Transfer rate 31.25 kBit/s
Communication protocol FF-816
Profile FF-890, FF-891
Bus address displayed value, not adjustable
Feeding voltage (FISCO) feeding by bus: 9 … 17.5 V Linear barrier: 9 … 24 V
Current consumption <12 mA
Max. current at fault (FDE) <17 mA
FF communication model certified according to ITK 4.6
1 Resource block Transmitter description
5 Transducer blocks Connection to measuring value operation
8 AI Function blocks Output of measuring values with status by fieldbus
1 AO Function block Input of measure value (calculation value) by fieldbus
4 DI Function blocks Output of messages and status by fieldbus
4 DO Function blocks Controlling by fieldbus
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to +70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
Specifications , COMFF 3400 X-085 module
107
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
108
Protos®
Protos® 3400 (X)
Communication model ,
Module Selection
AI TB 1Transducer Block
AI 1Analog Input
RBResource Block
AI 2Analog Input
AI 3Analog Input
AI 4Analog InputSe
lect
pro
cess
var
iab
le
Records
Calibration
Module I
Module II
Calc. Block I
Module Selection
AI TB 2Transducer Block
AI 5Analog Input
AI 6Analog Input
AI 7Analog Input
AI 8Analog InputSe
lect
pro
cess
var
iab
le
RecordsCalibration
AO Analog OutputAO TB
DI 1 Digital Input
DI 2 Digital Input
DI 3 Digital Input
DI 4 Digital Input
DO 1 Digital Output
DO 2 Digital Output
DO 3 Digital Output
DO 4 Digital Output
DI TB
DO TB
Meas. Value Correction
Unical®-Status
CONTACT-Status
Unical®-Message
Unical®-Step
HOLD-Control
PARSET
Unical®-Control
LOCK-Control
Fou
nd
atio
n F
ield
bu
s
Channel
Calc. Block II
Module I
Module II
Calc. Block I
Calc. Block II
1
2
3
4
5
6
7
8
21
11
12
13
14
31
32
33
34
109
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
110
Protos®
Protos® 3400 (X)
InduCon® I Digital sensor interface (EEx ia IIC T4)
Auxiliary power 3.3 ±5 %, 6 mA, Ri = 40 ohms Interface type RS 485 Transfer rate 9600 Bd Cable length max. 150 m
InduCon® II Digital sensor interface (EEx ia IIC T4)
Auxiliary power 3.3 ±5 %, 6 mA, Ri = 40 ohms Interface type RS 485 Transfer rate 9600 Bd Cable length max. 150 m
Unical® Unical® 9000 / Uniclean® 900 interface (EEx ia IIC T4)
Auxiliary power 6.8 V ±10 %, 15 mA, Ri = 54 ohms Interface type RS 485 Transfer rate 1200 Bd Cable length max. 20 m
ComFu® ComFu® C coordinator unit*} for wireless data tranfer (EEx ia IIC T4)
Auxiliary power 3.4 … 3.7 V; 30 mA, Ri = 10 ohms Interface type RS 485 Transfer rate 9600 Bd Cable length max. 20 m
Explosion protection ATEX: KEMA 03 ATEX 2530 II 2 (1) GD EEx em ib [ia] IIC T4 T 70 °C FM: NI, Class I, Div. 2, GP A, B, C, D T4 with IS circuits extending into Division 1 Class I, Zone 2, AEx nA, Group IIC, T4 Class I, Zone 1, AEx me ib [ia] IIC, T4 CSA: NI, Class I, Div. 2, Group A, B, C, D with IS circuits extending into Division 1 AIS, Class I, Zone 1, Ex ib [ia] IIC, T4 NI, Class I, Zone 2, Ex nA [ia] IIC
EMC NAMUR NE 21 and EN 61326
Emitted Interference Class B
Immunity to interference Industry
Lightning protection EN 61000-4-5, Installation Class 2
Nominal operating conditions
Ambient temperature: –20 to +55 °C (Ex: max. +50 °C) Rel. humidity: 10 to 95 % not condensing
Transport/Storage temperature
–20 to + 70 °C
Module case Color Protection Dimensions (mm) Connection terminals
Material PC/ABS-Blend black IP 20 w x l x h 118 x 91 x 21 Screwing terminals, single wire and stranded wire up to 2.5 mm‡
*) only for module FIU 3400–141
Specifications , FIU 3400 X-140 / FIU 3400-141 module
111
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Terminal assignment ,
112
Protos®
Protos® 3400 (X)
Product line ,
Accessories Order No.
SMARTMEDIA card ZU 0543128
AuditTrail card (replacement) ZU 0599
Pipe-mount kit ZU 0544
Panel-mount kit ZU 0545
Protective hood ZU 0548
Adapter M20 x 1,5 to NPT 1/2" ZU 0658
VP 8 connector plug ZU 0721
VP 8-ST connecting cable, 3 m, VP plug at both cable ends ZU 0710
VP 8-ST connecting cable, 5 m, VP plug at both cable ends ZU 0711
VP 8-ST connecting cable, 10 m, VP plug at both cable ends ZU 0712
Software Order No.
ProgaLog 3000 parameter setting and documentation software SW 3000
113
Isol
atio
n Am
plifi
ers
Tran
smitt
ers
Indi
cato
rs
Proc
ess
Ana
lyti
cs
Port
able
Met
ers
Labo
rato
ry M
eter
s
Sens
ors
Fitt
ings
Protos® 3400 (X)
Assembly examples ,
ZU 0544 pipe-mount kit For assembly on vertical or horizontal pipes or posts.
ZU 0548 protective hoodAdditional protection from direct weather exposure and mechanical damage.
ZU 0545 panel-mount kitFor assembly in panel cutout 144 x 194 mm
114
Protos®
Protos® 3400 (X)
Dimension drawings ,
159.5
70.5
147.539.5163
213
Front view Side view
Back view Panel cutout
Wall mounting Pipe/post mounting
45.5 72 144
141
194
189
72
R 15 ± 3M 6 inside (4x)
Contour Sub-enclosure
Panel cutout
Contour of enclosure front
72
72
150
Ø 6.5 (4x)
Ø 30 … 65